Encompass by Pella®
UNIT SECTIONS 3-3/8" Replacement Frame East and West Regions
AWNING
VH
3 3/8" OAW [86]
LJ VH
VENT HEAD LJ
LOCK JAMB
2 9/16" [66]
FRAME HEIGHT
3 1/2" [89]
VS
2 9/16" [66]
2 7/16" [62]
3 1/2" [89]
2 7/16" [62]
13/16" [21]
FRAME WIDTH VENT SILL
FH
FIXED HEAD
13/16" [21]
VS
FH
2 7/8" [73]
FJ
FS
FIXED JAMB
3 3/8" [86]
FRAME HEIGHT
FJ
2 7/8" [73]
13/16" [21] FRAME WIDTH
13/16" [21]
FS
FIXED SILL
3 3/8" [86]
Scale 3" = 1' 0" All dimensions are approximate.
East and West Regions Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
V-AW-14
Encompass by Pella®
UNIT SECTIONS 3-3/8" Replacement Frame - Composites with Integral Mullion East and West Regions
AWNING
VH
FH
3 3/8" OAW [86]
LJ
IM
2 15/16" [74]
FJ LJ
LJ
FH
VH
3 1/2" [89]
IM
FIXED HEAD
VENT HEAD
VS
INTEGRAL MULLION
VS
VENT SILL
HORIZONTAL VENT / VENT IM
INTEGRAL MULLION
VS
VENT SILL
2 7/16" [62]
IM
6" [152]
FRAME HEIGHT
5 3/8" [137]
HORIZONTAL FIXED / VENT
13/16" [21]
3 1/2" [89]
FRAME HEIGHT
VS
VH
LJ
VH
IM
East and West Regions
VS
VERTICAL VENT/VENT
VS LOCK JAMB
IM
INTEGRAL MULLION
LJ
LOCK JAMB
3 3/8" OAW [86]
LJ
3 1/2" [89]
6" [152]
2 7/16" [62]
13/16" [21]
FRAME WIDTH
Scale 3" = 1' 0" All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
V-AW-15
Encompass by Pella®
UNIT SECTIONS 3-3/8" Replacement Flush Flange Frame West Region Only
AWNING
3 3/8" OAW [86]
VH
LJ
VH
VENT HEAD LJ
3/8" [10]
2 7/16" [62]
2 9/16" [66]
LOCK JAMB
2 9/16" [66]
3 5/16" [84]
FRAME HEIGHT
3 1/2" [89]
VS
2 1/4" [57]
3 1/2" [89]
2 7/16" [62]
13/16" [21]
FRAME WIDTH VENT SILL
13/16" [21]
VS
FH
FJ
West Region Only FS
2 7/8" [73]
FH
FIXED HEAD FIXED JAMB
3/8" [10]
3 5/16" [84]
FRAME HEIGHT
FJ
2 1/4" [57]
2 7/8" [73]
13/16" [21] FRAME WIDTH
FIXED SILL
13/16" [21]
FS
3/8" [10]
3 5/16" [84]
Scale 3" = 1' 0" All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
V-AW-16
Encompass by Pella®
UNIT SECTIONS 3-3/8" New Construc tion Frame East and West Regions
AWNING
3 3/8" OAW [86]
VH
LJ
VENT HEAD
LJ
1 7/16" 1 15/16" [49] [36]
FRAME HEIGHT
VH
2 9/16" [66]
2 7/16" [62]
1 1/8" [29]
3 1/2" [89]
2 7/16" [62]
13/16" [21]
FRAME WIDTH
VENT SILL
13/16" [21]
VS
LOCK JAMB
2 9/16" [66]
3 1/2" [89]
VS
1 7/16" 1 15/16" [36] [49]
FH
2 7/8" [73]
FJ
FS
FH
FIXED HEAD FIXED JAMB
1 7/16" 1 15/16" [49] [36]
FRAME HEIGHT
FJ
1 1/8" [29] FIXED SILL
13/16" [21] FRAME WIDTH
13/16" [21]
FS
2 7/8" [73]
1 7/16" 1 15/16" [36] [49]
Scale 3" = 1' 0" Factory Applied jamb extensions are available in the East region only. All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
East and West Regions V-AW-17
Encompass by Pella®
UNIT SECTIONS 3-3/8" New Construc tion Frame - Composites with Integral Mullion East and West Regions
AWNING
3 3/8" OAW [86]
FH
VH
LJ
IM
2 15/16" [74]
FJ LJ
LJ
FH
VH
3 1/2" [89]
IM
FIXED HEAD
VENT HEAD
VS
INTEGRAL MULLION
VS
VENT SILL
HORIZONTAL VENT / VENT IM
INTEGRAL MULLION
VS
VENT SILL
2 7/16" [62]
IM
6" [152]
FRAME HEIGHT
5 3/8" [137]
HORIZONTAL FIXED / VENT
13/16" [21]
3 1/2" [89]
FRAME HEIGHT
VS
VH
LJ
VH
IM
VS
VERTICAL VENT/VENT
VS LOCK JAMB
IM
INTEGRAL MULLION
LJ
LOCK JAMB
1 7/16" 1 15/16" [49] [36]
LJ
1 1/8" [29]
3 1/2" [89]
6" [152]
2 7/16" [62]
13/16" [21]
FRAME WIDTH
Scale 3" = 1' 0" All dimensions are approximate.
East and West Regions Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
V-AW-18