橫軸窗_Encompass_剖面圖

Page 1

Encompass by Pella®

UNIT SECTIONS Frame Types Over view East and West Regions W E ST R E GIO N

Re pl acement Frame

Re pl a c e m e n t Fra m e

EAST EAST

WEST WEST

3 1/2" 3 1/2" [89] [89]

STANDARD STANDARD BLOCK BLOCKFRAME FRAME 3-3/8" 3-3/8"FRAME FRAMEDEPTH DEPTH

2 3/4" 2 3/4" [69] [69]

333/8" 3/8"OAW OAW

STANDARD STANDARD BLOCK BLOCKFRAME FRAME 3-3/8" 3-3/8"FRAME FRAMEDEPTH DEPTH

333/8" 3/8"OAW OAW

2 3/4" 2 3/4" [69] [69]

EAST REGION

3 1/2" 3 1/2" [89] [89]

CASEMENT

333/8" 3/8"OAW OAW

2 3/4" 2 3/4" [69] [69]

DOUBLE-WALL DOUBLE-WALL FLUSH FLUSHFLANGE FLANGE 3-3/8" 3-3/8"FRAME FRAMEDEPTH DEPTH

Ne w Co nstruction Frame

3 1/2" 3 1/2" [89] [89]

2 1/4" 2 1/4" [57] [57]

335/16" 5/16" [84] [84]

3 1/2" [89]

3 3/8" OAW

2 9/16" [66]

Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com

V-CM-19


Encompass by Pella®

UNIT SECTIONS 3-3/8" Replacement Frame East and West Regions

CASEMENT

3 3/8" OAW

3 3/8" OAW

FH

2 9/16" [66] VS

VENT SILL

FH

FIXED HEAD

FS

FIXED SILL

2 3/4" [70]

2" [51]

2 7/16" [62]

FJ

VENT HEAD

2 3/4" [69]

FRAME HEIGHT

VS

VH

FRAME HEIGHT

LJ

3 1/2" [89]

HJ

2 7/8" [73]

VH

13/16" [21]

13/16" [21]

FS

13/16" [21]

13/16" [21]

2 15/16" [74]

2 9/16" [66]

2 3/4" [70]

2 7/16" [62]

3 3/8" OAW

3 1/2" [89]

HJ

HINGE JAMB

LJ

FRAME WIDTH

LOCK JAMB

FJ

FIXED JAMB

FRAME WIDTH

Scale 3" = 1' 0"

East and West Regions

All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com

V-CM-20


Encompass by Pella®

UNIT SECTIONS 3-3/8" Replacement Frame - Composite with Integral Mullion East and West Regions

CASEMENT

3 3/8" OAW

3 3/8" OAW

FH

3 1/2" [89]

2 7/8" [73]

IM VH

VENT HEAD

VS

VENT SILL

FH

FIXED HEAD

IM

INTEGRAL MULLION

VS

VENT SILL

LJ

FRAME HEIGHT HJ

13/16" [21]

IM

VS FH

VH

HJ

5 3/8" [137]

HJ

2 7/16" [62]

VH

2 9/16" [66] FRAME HEIGHT

VS

HJ

IM

13/16" [21]

IM

2 7/16" [62]

HJ

VS

3 1/2" [89]

2 7/16" [62]

13/16" [21]

East and West Regions

2 9/16" [66]

3 3/8" OAW

6" [152]

HJ

HINGE JAMB

INTEGRAL MULLION

IM

LJ

LOCK JAMB

FRAME WIDTH

5 3/8" [137]

HJ

HINGE JAMB

2 7/16" [62]

13/16" [21]

2 3/4" [70]

5 3/8" [137]

2 9/16" [66]

3 3/8" [86]

3 1/2" [89]

IM

INTEGRAL MULLION

IM

INTEGRAL MULLION

HJ

HINGE JAMB

FRAME WIDTH

Scale 3" = 1' 0" All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com

V-CM-21


Encompass by Pella®

UNIT SECTIONS 3-3/8" Replacement Flange Frame West Region Only

CASEMENT

3 3/8" OAW

3 3/8" OAW

2 7/8" [73]

LJ

3 1/2" [89]

HJ

2 1/4" [57]

2 1/4" [57]

VH

VH

VENT HEAD

FH

FIXED HEAD

FS

FIXED SILL

VS

VENT SILL

2 3/4" [70]

2" [51]

2 7/16" [62]

FJ

2 9/16" [66]

2 3/4" [69]

FH

FRAME HEIGHT

FRAME HEIGHT

VS

3/8" [10]

13/16" [21]

13/16" [21]

FS

3 5/16" [84]

3/8" [10]

2 7/16" [62]

13/16" [21]

HJ

HINGE JAMB

2 1/4" [57]

West Region Only

3/8" [10]

2 9/16" [66]

3 3/8" OAW

3 1/2" [89]

3 5/16" [84]

LJ

LOCK JAMB

FRAME WIDTH

13/16" [21]

3/8" [10]

2 3/4" [70]

3 5/16" [84]

2 15/16" [74]

FJ

2 1/4" [57]

FIXED JAMB

FRAME WIDTH

Scale 3" = 1' 0" All dimensions are approximate.

Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com

V-CM-22


Encompass by Pella®

UNIT SECTIONS New Construc tion Frame with Optional Fac tor y Applied Jamb Extensions 1 East and West Regions

CASEMENT

3 3/8" OAW

3 3/8" OAW

FRAME HEIGHT

FH

2 9/16" [66] VS

VENT SILL

FH

FIXED HEAD

FS

FIXED SILL

2 3/4" [70]

2" [51]

2 7/16" [62]

FJ

VENT HEAD

5/8" [16]

2 3/4" [69]

VS

VH

FRAME HEIGHT

LJ

3 1/2" [89]

HJ

2 7/8" [73]

VH

13/16" [21]

13/16" [21]

FS

1 7/16" 1 15/16" [36] [49]

Scale 3" = 1' 0" (1) Factory Applied jamb extensions are available in the East region only. All dimensions are approximate.

1 7/16" 1 15/16" [36] [49]

4 9/16" [116] 6 9/16" [167]

Optional Factory Applied Wood Jamb Extensions

East and West Regions 5" [128]

4 9/16"

6 9/16"

2 7/16" [62]

13/16" [21]

13/16" [21]

2 15/16" [74]

HJ

1 1/8" [29]

HINGE JAMB

2 3/4" [70]

2 9/16" [66]

1 7/16" 1 5/16" [36] [33]

3 1/2" [89]

3" [77]

LJ

FRAME WIDTH

LOCK JAMB

FJ

1 1/8" [29]

FIXED JAMB

FRAME WIDTH

Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com

V-CM-23


Encompass by Pella®

UNIT SECTIONS 3-3/8" New Construc tion Frame - Composites with Integral Mullion East and West Regions

CASEMENT

3 3/8" OAW

3 3/8" OAW

FH

3 1/2" [89]

2 7/8" [73]

IM VH

VENT HEAD

VS

VENT SILL

FH

FIXED HEAD

IM

INTEGRAL MULLION

LJ

FRAME HEIGHT HJ

13/16" [21]

IM

VS VH

HJ

FH

VS

HJ

IM

VENT SILL

13/16" [21]

IM

1 7/16" 1 15/16" [36] [49] 2 7/16" [62]

HJ

2 9/16" [66]

2 7/16" [62]

VH

FRAME HEIGHT

VS

5 3/8" [137]

HJ

VS

2 7/16" [62]

6" [152]

13/16" [21]

East and West Regions

2 9/16" [66]

3 3/8" OAW

3 1/2" [89]

HJ

HINGE JAMB

IM

INTEGRAL MULLION

LJ

LOCK JAMB

FRAME WIDTH

5 3/8" [137]

HJ

HINGE JAMB

1 1/8" [29]

2 7/16" [62]

13/16" [21]

2 3/4" [70]

5 3/8" [137]

2 9/16" [66]

1 7/16" 1 15/16" [36] [49]

3 1/2" [89]

IM

INTEGRAL MULLION

IM

INTEGRAL MULLION

HJ

HINGE JAMB

FRAME WIDTH

Scale 3" = 1' 0" All dimensions are approximate. Pella 2015 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com