2818 maxfield nbc inspection report

Page 1

dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

R e s id e n t i a l & Co m m e r c ia l I n s p e c t i o n S e rv i c e s Env i ro n m e n t a l S u rv e ys & Testing Services S e r v i n g T o p e k a a n d L a w r e n c e S i n c e 1 9 8 9

Brenda Harmon

dotloop verified 02/08/14 3:41PM CST X1NU-4BF7-VFIV-LISH


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

Building Inspection Report

PROPRIETARY INFORMATION 13-340

PROPERTY ADDRESS 2818 SW Maxfield Topeka, Kansas CLIENT Scott Harmon

SELLING AGENCY 1 Source Real Estate c/o Raul Rubio Guevara

KANSAS REGISTRATION: BUILDING TYPE: EST. BUILDING AGE: # OF STORIES TYPE OF USE: TEMPERATURE:

# 0110-0004 Frame 21 yr. Two Residential 43 F

FRONT ELEVATION FACES: INSPECTION DATE: INSPECTION TIME: INSPECTORS NAME: VACANT/OCCUPIED: SOIL CONDITIONS:

Published By: National Building Consultants - 2013 - P.O. Box 4172, Topeka, Kansas 66604

West 12/17/13 9:20 –11:45 am R. Pimentel C.B.O. Occupied Dry

Page 2


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

GLOSSARY

TYPICAL CONDITION - This qualifier is an opinion that is used to indicate that the item was found to be in a working or functional condition that is commensurate for its age and overall condition. Moderate to advanced wear, weathering and deterioration may exist with this denotation. MARGINAL - This qualifier is an opinion that is used to indicate that the item was found to be in working or functional condition, but had exceeded the normal/expected life. Items listed as Marginal may require immediate repair, service, or replacement. Advanced or excessive weathering, wear and deterioration may exist. This item should be deemed as having a limited remaining life expectancy. POOR/UNSAFE - This qualifier is an opinion that is used to indicate that the item was found to be in a nonworking/nonfunctioning condition and may require immediate repair or replacement. This qualifier can also denote an item with advanced deterioration and substantial defect. This qualifier may also denote an item that creates a hazard to the building or its occupants.

RECOMMENDED IMMEDIATE REPAIRS Any defect or concern noted within the body of the inspection report, should be addressed by a new homeowner in a timely manner. All deficiencies listed in the report either as a specific statement of defect in the Comments portion of the report, or as indicated by a Marginal or Poor denotation, or when identified in the Area of Concern check-off sections of the report should be eliminated. Items listed in this section of the summary are recommended for immediate repair or replacement. In most cases there will be a significant difference between replacement as opposed to repair.

COST ESTIMATES The Cost Estimates provided in the summary of the report will always list the least expensive option for corrective action. The cost estimates provided in the summary of the inspection report should be used only as a guideline for obtaining written bids from qualified contractors. Actual bid proposals should be solicited from not less than three qualified, insured, and/or licensed contractors.

RECOMMENDED INTERMEDIATE MAINTENANCE/REPAIRS The items listed in this section of the inspection should be addressed in a timely manner. Intermediate maintenance and repairs must be completed on a regular basis or on a need-to basis. Lack of proper intermediate maintenance can create a significant threat to a building or a portion of the mechanical systems. Also listed in this area items that were functional at the time of the inspection and/or in a general condition that is commensurate with the age of the item, but have a limited remaining expected life.

AREAS NOT COVERED BY THIS INSPECTION REPORT The following areas and systems are not a part of this inspection report and if applicable should be addressed through a separate inspection. Any area not mentioned in the inspection report should be addressed through a separate inspection. The following is a list of typical items not included in this report: Sprinkler Systems, Septic Systems, Main Underground Sewer Line, Solar Systems, EIFS, Mold, Asbestos, Lead-based Paint, Indoor Air Quality, Swimming Pools/Equipment, Hot Tubs, Saunas, Central Vacuum Systems, Fireplace Liners, Underground piping Underground wiring, or items concealed within construction.

Published Published By: National By: National Building Building Consultants Consultants - 2013- -2006 P.O.- Box P.O.4172, Box 4172, Topeka, Topeka, Kansas Kansas 6660466604 Page 3


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

INSPECTION REPORT SUMMARY RECOMMENDED IMMEDIATE REPAIRS The following items are recommended immediate repairs. Any Area of Concern noted within the body of the report may be listed in this portion of the report. Actual bids should be obtained for each recommended immediate repair.

None at this time.

RECOMMENDED INTERMEDIATE MAINTENANCE/REPAIRS The items listed in this section of the summary are considered regular maintenance or recommended improvements that will help keep your house in good condition and prevent costly repairs.

When the furnace or water heater is replace install two combustion air grilles on the wall of the mechanical room. When the sump pump is replaced, install a tight fitting cover to the sump pump basin. I

Published By: National Building Consultants - 2013 P.O. Box 4172, Topeka, Kansas 66604

Page 4


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

SITE ELEMENTS

GRADE AT HOUSE

 0 0 0 0 0

PATIO

0 0 0  0 0

PROPERTY GRADE

 0 0 0 0 0

SIDEWALKS

 0 0 0 0 0

RETAINER WALL(S)

0 0 0  0 0

FRONT PORCH

 0 0 0 0 0

DRIVEWAY

 0 0 0 0 0

DECK

 0 0 0 0 0

AREAS OF CONCERN Improper Grade/Slope Drainage Ditch Restriction Depressions Near Foundation

Advanced Settling Advanced Spalling Advanced Cracking

Concrete Deck Piers Damaged Deck Framing Improper Framing

Comments: It is recommended that the grade around the perimeter of the foundation have a minimum slope of six inches within the first ten feet of the foundation walls. Minor settling was noted at the driveway concrete slab adjacent to the garage. Caulk/seal the construction joints at the driveway and sidewalk to prevent settling/damage. It is generally recommended that deck support columns bear on concrete piers that extend down to the frost line and extend up not less than six inches above grade. Maintain the stain or water proof compound on the deck planks, stair riser, and guardrail. The bottom step of the deck stairs is in direct contact with soil. The bottom step can be removed and replaced with concrete patio blocks.

EXTERIOR ELEMENTS SIDING

 0 0 0 0 0

TRIM

 0 0 0 0 0

FACIA/SOFFITS

 0 0 0 0 0

WINDOW WELL

 0 0 0 0 0

MASONRY VENEER

 0 0 0 0 0

FRONT DOOR

 0 0 0 0 0

CHIMNEY

 0 0 0 0 0

FENCING

0 0 0  0 0

AREAS OF CONCERN Damaged Siding/Trim Unprotected Openings Exposed Soffits/Facia Boards

Damaged Mortar Joints No Weep-Holes Window Well Covers

X X

Improper Chimney Height Improper Chimney Screen/Cap Damaged Chimney Liner

Comments: The composition siding have been properly applied to the exterior wall framing. The siding panels have weathering and delamination that is commensurate with the age of the house. Routine maintenance of the siding panels includes; applying a primer/sealer to the bottom edge of the panels to prevent delamination, caulking the joints between two siding panels, caulking the joints of the door/window trim boards, caulking over the nail head that were driven past the plane of the surface, and around all penetrations through the siding panels. Prep and paint the trim boards on the chimney chase, as needed. The brick veneer on the front of the house has no significant damage to the brick unit or mortar joints. A window well cover is recommended. The chimney terminates at the proper height above the roof. A proper chimney cricket has been recently constructed on the west side of the chimney chase to divert run-off around the chimney chase and prevent water intrusion/water damage. Published By: National Building Consultants P.O. Box Topeka, 4172, Topeka, Kansas Published By: National Building Consultants - 2013--2006 P.O.-Box 4172, Kansas 66604 66604 Page 5


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

ROOF ELEMENTS

ROOF COVER

 0 0 0 0 

GUTTERS

 0 0 0 0 0

FLASHINGS

 0 0 0 0 0

DOWNSPOUTS

 0 0 0 0 

GUTTER SCREENS

0 0 0  0 0

DRIP EDGING

 0 0 0 0 0

Sloped X Low Slope

Asphalt X Wood

Concrete Tile Rubber

Estimated Age 1-5 yrs Multiple Layers No

Org. Life Span Felt Apprx #

30 yrs

AREAS OF CONCERN EXCESSIVE GRANULAR LOSS EXCESSIVE SPACING EXCESSIVE SPLITTING

DAMAGED SHINGLES DRIP EDGING PIPE FLASHINGS

ROOF JACKS UNSEALED GUTTER JOINTS GUTTER DEBRIS

Comments: The impact-resistant composition roof shingles have been properly applied to solid roof sheathing and have properly adhered. All of the flashings were replaced with the new shingles were installed.

GARAGE/ACCESSORY FRAMING

 0 0 0 0 0

OVERHEAD DOOR (S)

 0 0 0 0 0

CEILING

 0 0 0 0 

ELECTRIC OPENER (S)

 0 0 0 0 0

WALLS

 0 0 0 0 0

ENTRY DOOR

 0 0 0 0 

FLOOR/CONCRETE SLAB

 0 0 0 0 0

ELECTRIC CIRCUITS

 0 0 0 0 0

AREAS OF CONCERN IMPROPER FOUNDATION DAMAGED FOUNDATION SIGNIFICANT DRY-ROT

MOISTURE DAMAGE IMPROPER FRAMING FIRE SEPARATION

DAMAGED GARAGE DOOR DAMAGED CONCRETE SLAB AUTO-STOP CONTROLS

Comments: The garage door opener was operational. The garage door opener is equipped with auto-stop infrared light sensors. The dead bolt lock on the exterior entry door did not operate properly and should be repaired. The sheetrock ceiling has minor damage at the tape joints. The damaged tape joints were caused by poor workmanship and not by foundation settling.

Published Published By: National By: National Building Building Consultants Consultants - 2013--2006P.O. Box P.O.4172, Box 4172, Topeka, Topeka, Kansas Kansas 6660466604 Page 6


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

FOUNDATION/BASEMENT

SLAB ON GRADE

 0 0 0 0 0

FOOTINGS

0 0 0 0  0

FOUNDATION WALLS

 0 0 0 0 0

FLOOR SHEATHING

 0 0 0 0 0

BEAMS

 0 0 0 0 0

PIERS/COLUMNS

 0 0 0 0 0

BEAM POCKETS

 0 0 0 0 0

FLOOR JOISTS

 0 0 0 0 0

SUMP PUMP(S)

 0 0 0 0 0

FLOOR DRAIN

 0 0 0 0 0

STAIRS

 0 0 0 0 0

WINDOWS

 0 0 0 0 0

VAPOR BARRIER

0 0 0  0 0

FRAMED WALLS

 0 0 0 0 0

AREAS OF CONCERN FOUNDATION DAMAGE CRACKS AND FISSURES BEAM POCKET DAMAGE IMPROPER ACCESS NO VAPOR BARRIER

WATER INTRUSION IMPROPER EGRESS WINDOWS IMPROPER FOUNDATION HEIGHT 18” CLEARANCE TO FRAMING LATERAL DISPLACEMENT

FLOOR JOISTS DEFLECTION IMPROPERLY NOTCHED JOISTS CONCRETE SETTLING OR HEAVING UNINSULATED DUCTS/WATER LINES IMPROPER BEAMS/COLUMNS

Comments: The eight inch formed and poured concrete foundation walls have no significant lateral displacement or damage. The floor joists are properly sized, spanned, and spaced. The floor sheathing has been properly applied to the floor joists. The steel I-beam is properly sized and supported by steel columns and beam pockets. The sump pump has advanced corrosion/rust, but is fully functional at this time. A tight fitting sump basin cover is recommended when the sump pump is replaced.

Published Published By: National By: National Building Building Consultants Consultants - 2013- -2006 P.O.- Box P.O.4172, Box 4172, Topeka, Topeka, Kansas Kansas 6660466604 Page 7


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

INTERIOR ELEMENTS

WALLS

 0 0 0 0 0

CEILINGS

 0 0 0 0 0

FLOOR (S)

 0 0 0 0 0

FLOOR COVERINGS

 0 0 0 0 0

WINDOWS

 0 0 0 0 0

DOORS

 0 0 0 0 0

PATIO DOOR (S)

 0 0 0 0 0

ENTRY DOORS

 0 0 0 0 0

SWITCHES

 0 0 0 0 0

RECEPTACLES

 0 0 0 0 0

STAIRS

 0 0 0 0 0

HANDRAIL

 0 0 0 0 0

SMOKE DETECTOR (S)

0 0 0 0 0 

FIREPLACE

 0 0 0 0 0

FIREBOX

 0 0 0 0 0

SMOKE CHAMBER

 0 0 0 0 0

GAS LOGS

 0 0 0 0 0

GAS VALVE (S)

 0 0 0 0 0

AREAS OF CONCERN WALLS\CEILINGS CRACKS WALL\CEILING DAMAGE WATER DAMAGE\STAINS UNLEVELED FLOORS JAMBS UNSQUARE

X

DAMAGED FLOORING WINDOW FRAMES DAMAGED WINDOWS EGRESS WINDOWS DAMAGED DOOR (S)

FIREBOX JOINTS IMPROPER\DAMAGED HEARTH DAMAGED FIREBOX CREOSOTE DEPOSITS UNSAFE WOOD-BURNING DEVICE

Comments: The windows were in good working condition. All of the exterior doors and first floor windows have proper security hardware. The wall outlets, wall switches, and light fixtures throughout the house were operational. Replace the batteries within the smoke detectors biannually and test the smoke detectors for interconnectivity. Smoke detectors are recommended in each bedroom. The factory-built fireplace is equipped with a set of vented gas logs. The fireplace can be used with gas logs or as a wood-burning appliance. Keep the damper in the fully open position when operating the vented gas logs. A wall switch for a future circulating fan has been installed adjacent to the fireplace.

Published Published By: National By: National Building Building Consultants Consultants - 2013- -2006 P.O.- Box P.O.4172, Box 4172, Topeka, Topeka, Kansas Kansas 6660466604 Page 8


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

KITCHEN ELEMENTS

SINK

 0 0 0 0 0

FAUCET

 0 0 0 0 0

PLUMBING

 0 0 0 0 0

DISPOSER

 0 0 0 0 0

FLOORING

 0 0 0 0 0

DISHWASHER

 0 0 0 0 0

RANGE

 0 0 0 0 0

RANGE OUTLET

 0 0 0 0 0

OVEN

 0 0 0 0 0

JENN AIR EXHAUST

0 0 0  0 0

RANGE FAN

 0 0 0 0 0

OVEN LIGHT

 0 0 0 0 0

RANGE FAN LIGHT

 0 0 0 0 0

CEILING LIGHT

 0 0 0 0 0

COUNTERTOPS

 0 0 0 0 0

COMPACTOR

0 0 0  0 0

RECEPTACLES

 0 0 0 0 0

SWITCHES

 0 0 0 0 0

AREAS OF CONCERN IMPROPER P-TRAP IMPROPER TRAP-VENT NO SHUT-OFF VALVES

IMPROPER RANGE EXHAUST IMPROPER GAS CONNECTOR FLOOR DAMAGE

GFCI RECEPTACLES CLEAN RANGE FAN FILTERS SLOW DRAINAGE OBSERVED

Comments: The outlets within six feet of are GFCI protected.

WASHER/DRYER STANDPIPE

 0 0 0 0 0

DRYER RECEPTACLE

 0 0 0 0 0

DRYER VENT

 0 0 0 0 0

UTILITY SINK

0 0 0  0 0

AREAS OF CONCERN IMPROPER HEIGHT IMPROPER TRAP/VENT MOISTURE DAMAGE

IMPROPER DRYER RECEPTACLE IMPROPER DRYER CONDUCTOR IMPROPER OVERFLOW PAN

IMPROPER VENT MATERIAL IMPROPER GAS CONNECTOR IMPROPER VENT HOOD

Comments: Clean the dryer vent hood and vent pipe annually.

Published Published By: National By: National Building Building Consultants Consultants - 2013- -2006 P.O.- Box P.O.4172, Box 4172, Topeka, Topeka, Kansas Kansas 6660466604 Page 9


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

BATHROOMS

Bathroom - 2nd Floor

TUB/SHOWER

 0 0 0 0 0

SHOWER DOOR

0 0 0  0 0

TUB SHOWER FAUCET

 0 0 0 0 0

TOILET

 0 0 0 0 0

SINK (S)

 0 0 0 0 0

FAUCET (S)

 0 0 0 0 0

EXHAUST FAN

 0 0 0 0 0

SHUT-OFF VALVES

 0 0 0 0 0

GFCI OUTLET

0 0 0 0 0 

DRAIN LINES

 0 0 0 0 0

TUB/SHOWER

 0 0 0 0 0

SHOWER DOOR

0 0 0  0 0

TUB/SHOWER FAUCET

 0 0 0 0 0

TOILET

 0 0 0 0 0

SINK (S)

 0 0 0 0 0

FAUCET (S)

 0 0 0 0 0

EXHAUST FAN

 0 0 0 0 0

SHUT-OFF VALVES

 0 0 0 0 0

GFCI OUTLET

 0 0 0 0 

DRAIN LINES

 0 0 0 0 0

TUB/SHOWER

 0 0 0 0 0

SHOWER DOOR

 0 0 0 0 0

TUB/SHOWER FAUCET

 0 0 0 0 0

TOILET

 0 0 0 0 0

SINK (S)

 0 0 0 0 0

FAUCET (S)

 0 0 0 0 0

EXHAUST FAN

 0 0 0 0 0

FLUSH VALVE

 0 0 0 0 0

GFCI OUTLET

 0 0 0 0 0

DRAIN LINES

 0 0 0 0 0

Bathroom - Master

Bathroom - Basement & 1/2

Comment: The outlets in the master bathroom and 2nd floor bathroom are connected to and protected by the GFCI outlet in the 1/2 bathroom. The master bathroom tub is not equipped with a pop-up drain stopper.

page 10


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

ATTIC AREA

RAFTER SYSTEM

 0 0 0 0 0

SHEATHING

 0 0 0 0 0

PURLINS

 0 0 0 0 0

VENTILATION

 0 0 0 0 0

CEILING JOIST

 0 0 0 0 0

INSULATION

 0 0 0 0 0

OVERSPANNED RAFTERS DEFLECTED RAFTERS DEFLECTED SHEATHING

AREAS OF CONCERN

IMPROPER PURLIN IMPROPER RIDGE BOARD IMPROPER ELECTRICAL SPLICE

MOISTURE DAMAGE INSUFFICIENT INSULATION INSUFFICIENT VENTILATION

Comments: The insulation is rated at approx. R-28 as was recommended by the Dept. of Energy for this region of the country when the house was originally constructed. The attic was inspected from the attic access opening in the garage and 2nd floor bedroom.

ELECTRICAL ELEMENTS SERVICE HEAD

 0 0 0 0 0

SERVICE LOOP

 0 0 0 0 0

SERVICE CONDUIT

 0 0 0 0 0

SERVICE CABLE

 0 0 0 0 0

GROUNDING ROD

 0 0 0 0 0

SERVICE CABLE SIZE

 0 0 0 0 0

CONDUCTORS

 0 0 0 0 0

BREAKERS/FUSES

 0 0 0 0 0

AFCI BREAKER (S)

0 0 0  0 0

GROUNDING/BONDING  0 0 0 0 0

SERVICE PANEL

 0 0 0 0 0

RECEPTACLES

 0 0 0 0 0

AREAS OF CONCERN IMPROPER ENTRANCE CABLES IMPROPER SERVICE CAPACITY KNOB AND TUBE WIRING

IMPROPER BREAKER/FUSE SIZE DAMAGED BREAKER/FUSE MULTI-TAPS IN SERVICE PANEL

IMPROPERLY WIRED OUTLETS IMPROPER SPLICES OPEN ELECTRICAL BOX

Comments: The electrical service capacity is 150 amps. The ampacity (demand) is approximately 110 amps. The electrical service panel is properly grounded and bonded. All of the circuit breakers and branch conductors are properly sized.

Published By: National Building Consultants - 2013 - P.O. Box 4172, Topeka, Kansas 66604

Page 11


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

PLUMBING

WATER SERVICE

 0 0 0 0 0

WATER PIPING

 0 0 0 0 0

WATER PRESSURE

 0 0 0 0 0

PIPING SUPPORT

 0 0 0 0 0

MAIN SHUT-OFF

 0 0 0 0 0

PRESSURE REGULATOR

0 0 0  0 0

BACK-FLOW DEVICE

0 0 0  0 0

DRAIN LINES

 0 0 0 0 0

FIXTURE DRAINAGE

 0 0 0 0 0

FIXTURE TRAPS

 0 0 0 0 0

GAS LINES

 0 0 0 0 0

GAS SHUT-OFFS

 0 0 0 0 0

GAS LINE SUPPORT

 0 0 0 0 0

GAS TANK (LP)

0 0 0  0 0

AREAS OF CONCERN IMPROPER P-TRAPS IMPROPER VENTS DRAIN LINE CORROSION

ACTIVE WATER LINE LEAKS IMPROPERLY GRADED DRAIN LINE PRONE TO FREEZE DAMAGE

IMPROPER PIPE MATERIAL SLOW DRAINAGE CORROSION IN WATER LINES

Comments: No leaks were noted at the drain lines or water lines that were visible for inspection. No gas leaks were measured within the house or at the gas meter.

WATER HEATER MANUFACTURER: Rheem EST. AGE 21 ORIG. LIFE SPAN 10 to 15 yrs UNIT SIZE 40 GAL. NAT. GAS X L.P. GAS ELECT. SOLAR OTHER

TANK CONDITION

 0 0 0 0 0

WATER TEMP.

126 F.

BURNER

 0 0 0 0 0

PILOT ASSEMBLY

 0 0 0 0 0

SUPPLY VALVE

 0 0 0 0 0

VENT PIPE

 0 0 0 0 0

RELIEF VALVE

 0 0 0 0 0

SERVICE VALVE

 0 0 0 0 0

 0 0 0 0 

Comments: The recommended temperature setting for the water heater is 120F. Flush 1-5 gallons from the service valve at the bottom of the water heater to prevent sediment accumulation that reduces heat recovery time and shortens the life of the water heater.

Published Published By: National By: National Building Building Consultants Consultants - 2013 - 2006P.O. Box P.O. 4172, Box Topeka, 4172, Topeka, Kansas Kansas 66604 66604 Page 12


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

HEATING MANUFACTURER: York EST. AGE: 21 years ORIG. LIFE SPAN: 20 years FUEL TYPE: NAT. GAS X L.P. GAS ELECT. SOLAR SOLID FUEL OTHER UNIT TYPE: FORCED AIR X GRAVITY BOILER HEAT PUMP CONVECTION UNIT SIZE: GAS 80,000 BTU/HR ELECT Kw/hr FURNACE LOCATION: BSMT MECHANICAL ROOM X CRAWL SPACE ATTIC GARAGE PLENUM/TRUNK MATERIAL: STEEL X FIBERGLASS PLASTIC CONCRETE BRANCH DUCT MATERIAL: STEEL X FIBERGLASS PLASTIC CONCRETE

FURNACE (S)

 0 0 0 0 0

MAIN PLENUM

 0 0 0 0 0

TRUNK DUCT

 0 0 0 0 0

BRANCH DUCTS

 0 0 0 0 0

SUPPLY AIR 123 F.

 0 0 0 0 0

RETURN AIR 68 F.

 0 0 0 0 0

BURNERS

 0 0 0 0 0

PILOT ASSEMBLY

 0 0 0 0 0

FAN/MOTOR

 0 0 0 0 0

CO TEST (EQUIP./VENT)

0 0 0  0 0

VENT PIPE

 0 0 0 0 0

EQUIP. CLEARANCE

 0 0 0 0 0

COMB. AIR SUPPLY

0 0 0 0 0 

GAS SUPPLY

 0 0 0 0 0

AIR FILTER

 0 0 0 0 

CIRCULATING PUMP

0 0 0  0 0

HYDRONIC PIPING

0 0 0  0 0

EXPANSION TANK

0 0 0  0 0

ELECTRICAL

 0 0 0 0 0

UV AIR PURIFIER

0 0 0  0 0

HUMIDIFIER

0 0 0  0 0

VENT CONNECTOR PIPE

 0 0 0 0 0

AREAS OF CONCERN SERVICE FURNACE/BURNERS NO ELECTRICAL DISCONNECT INSUFFICIENT COMBUSTION AIR

IMPROPER AIR TEMPERATURES UNIT IMPROPERLY CYCLED IMPROPER VENT CLEARANCE

CORROSION NOTED ON VENT IMPROPER VENT TERMINATION ASBESTOS MATERIAL NOTED

Comments: The furnace properly cycled and produced the recommended air temperature rise within the heat exchanger. Clean the construction dust from the furnace combustion chamber, inducer fan motor, and from the fan compartment. Check the air filter every month for the first six months to determine the proper replacement schedule. When the furnace is replaced, install two combustion air grilles on the wall of the mechanical room.

Published Published By: National By: National Building Building Consultants Consultants - 2013 -- 2006 P.O. -Box P.O. 4172, Box Topeka, 4172, Topeka, KansasKansas 66604 66604 Page 13


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

AIR CONDITIONING MANUFACTURER: York EST. AGE 21 yrs ORIG. LIFE SPAN 20 yrs FUEL TYPE: NAT. GAS L.P. GAS ELECT. X SOLAR THERMAL STORAGE OTHER UNIT TYPE: CENTRAL SPLIT SYSTEM X HEAT PUMP GEOTHERMAL PORTABLE OTHER UNIT SIZE: 36,000 BTU/hr AMPACITY RATING: 16.3AMP MAX. CIRCUIT PROTECTION: 35 AMP PLENUM/TRUNK MATERIAL: STEEL X FIBERGLASS PLASTIC CONCRETE OTHER BRANCH DUCT MATERIAL: STEEL X FIBERGLASS PLASTIC CONCRETE OTHER

CONDENSER UNIT

 0 0 0 0 

CONDENSER COILS

 0 0 0 0 0

CONDENSER FAN

 0 0 0 0 0

SERVICE LINES

 0 0 0 0 0

DISCONNECT

 0 0 0 0 0

ELECT. CONDUCTOR

 0 0 0 0 

SUPPLY AIR F

0 0 0 0 0 

RETURN AIR F

0 0 0 0 0 

TRUNK DUCT

 0 0 0 0 0

BRANCH DUCTS

 0 0 0 0 

CONDENSATE LINE

 0 0 0 0 

CONDENSATE PUMP

0 0 0  0 0

AHU FAN

 0 0 0 0 0

AIR SPEED/QUANTITY

 0 0 0 0 0

AIR FILTER

 0 0 0 0 0

CONDENSATE DAMAGE

0 0 0  0 0

PROPER OUTLET

 0 0 0 0 0

MISC CONTROLS

 0 0 0 0 0

AREAS OF CONCERN CONDENSER UNIT RUST NOT ABOVE ADJACENT GRADE CONDENSER COILS DAMAGE

IMPROPER BREAKER/FUSE RATING SERVICE LINE SEALANT/CAULKING CONDUCTOR REQUIRES CONDUIT

CONDENSATE DAMAGE DUCT INSULATION ASBESTOS MATERIAL NOTED

Comments: The air conditioning system could not be tested because the outdoor air temperature was less than 50F at the time of the inspection. Caulk around the service lines where they pass through the siding panel. Clean the condenser unit coils at the beginning of the cooling season and whenever debris becomes embedded on the condenser unit coils to improve the efficiency of the cooling system.

Published Published By: National By: National Building Building Consultants Consultants - 2013 -- 2006 P.O. -Box P.O. 4172, Box Topeka, 4172, Topeka, KansasKansas 66604 66604 Page 14


dotloop signature verification: www.dotloop.com/my/verification/DL-48928356-3-2I29

About National Building Consultants

National Building Consultants has provided building inspections and environmental testing services in the Topeka and Lawrence area for over twenty years. First incorporated by Ralph Pimentel in 1989, NBC has been the leading building inspection and environmental testing firm in Topeka for over fifteen years. Whether a commercial facility or an investment property, whether building your dream-home or purchasing your first home, NBC can provide you with the most comprehensive construction inspections available in the real estate and construction industry. A PARTIAL LIST OF CERTIFICATIONS, DEGREES, LICENSES AND AWARDS RECEIVED BY RALPH PIMENTEL INCLUDE:

Appointed By Governor Sebelius To The State of Kansas Home Inspectors Board, 2nd District Reappointed By Governor Parkinson To The State of Kansas Home Inspectors Board, Vice-Chair Reappointed By Governor Brownback To The State of Kansas Home Inspectors Board, Chairman State of Kansas Home Inspectors License Former Building Inspector for the City of Topeka Former Building Inspector for the City of Lawrence Certified Building Inspector, ICBO, ICC Certified Mechanical Inspector, ICBO, IAMPO Certified Plumbing Inspector, ICBO, IAMPO State of Kansas Licensed Radon Measurement Technician Certified Asbestos Inspector, AHERA, Mayhew Environmental Training Association Certified Indoor Air Quality Specialist, University of Kansas. American with Disabilities Act Compliance Specialist, ICBO Masters License City of Topeka Masters License City of Lawrence International Journeyman Certification Local #77 Bachelor of Arts, Business Administration, Washburn University Awarded Multiple United States Patents Published by Journal of Light Construction Published by International Conference of Building Officials Published by the International Association of Plumbing and Mechanical Officials Listed in Who’s Who in Business Executives and Professional of America 1997 INSPECTIONS FOR COMMERCIAL AND RESIDENTIAL PROJECTS THAT INCLUDE:

Over 12,500 Residential Inspections The West Ridge Regional Mall, Topeka The Expocentre, Topeka The Heartland Race Park Tower Facility, Topeka Washburn University Computer Center, Topeka The Performing Arts Center, Topeka Santa Fe Office and Computer Complex, Topeka Tanger Outlet Mall, Lawrence Lawrence Medical Center The Superconductivity Science Center, Lawrence

Published By: National Building Consultants - 2013 -- 2006 P.O. -Box 4172, KansasKansas 66604 66604 Page 15 Published By: National Building Consultants P.O. Box Topeka, 4172, Topeka,