Course Overview • • • • • • • •

Safety Issues Installation environment Lamp changing Overview of components of the cinema system Building a secure system for cinemas Upgrading the software Operational procedures including loading content and keys. Best installation practice including uniformity jig


Safety • Lamp – Xenon bulb • • • • •

Under pressure Risk of explosion if lamp glass housing is damaged Need to wear safety clothing when handling Need to dispose of old lamp safely Need to draw attention of customers to safe lamp handling procedures


Safety • Power – SRX-220/210 uses 400v 3 phase power for lamp – Start up voltage – +40Kv – Running voltage – +35v DC 130 Amp – Caution needed if working near to the lamp exciter circuit power supply (Normally covered in mid section of projector)


Safety • Exposed high voltage connections inside the unit • Both SRX-220 and SRX-220 require power cable connections that need to be permanently wired into the system • These need to be of the correct power rating and suitably protected


Safety • When working inside the projector, if it does not have to be switched on, disconnect the power connector from the wall and leave the connector were it can be seen • Do not leave unused supply cables with exposed ends unattended – tape them and secure them away.