SRX-R220/210 Power Requirements
Three-phase power voltage setting
For R220/210, single-phase power supply switches automatically and can accept 100v to 250v AC. The three-phase power supply for the lamp must be set manually to either 200V or 400V,depending on the standard voltage in the country where the projector is installed. On shipment, it is set to 200V.
For setting, make sure to turn off the power.
Check the setting Voltage
Connection of AC power supply
Three-phase L1/L2/L3/N/PE
L1 L2 L3
Single-phase AC INLET
N
PE
Connections Picture inputs A~C, Ethernet, Inter lock
Safety Interlock • What is Safety Interlock? – Legal Safety Feature – Shuts down projector when cinema fire alarm activated – Normally simple open or closing contact • R220/210 has a 15 pin connector
Difference point list R220 and R210 R220
R210
Correspondence lamp
4.2KW (LKRX-2042A)
3.0KW (LKRX-2030A) 2.0KW (LKRX-2020A)
Light output (When the screen gain is 1.8)
14ft-L (@ 20m Screen)
14ft-L (@ 17m Screen) 14ft-L (@ 14m Screen)
Current value
Single-phase 11-5A ( 100-240V ) Three-phase 21A/11A ( 200-208V/380-415V )
Single-phase 11-5A ( 100-240V ) Three-phase 13.5/7A ( 200-208V/380-415V )
Setting of mode of lamp power supply
Mode:B
Mode:C
ng of mode of lamp power supply for 4.2Kw, 3Kw, 2Kw lamp
R220
MODE B
R210
MODE C
Luminance sensor and Lamp wattage R220/210 is equipped with a luminance sensor in the optical unit. When the LAMP POWER is changed, the luminance sensor value (not the LAMP POWER value) is saved. After Calibration, the table of the Lamp power and the Luminance sensor value is revised. When recalling the FUNCTION MEMORY, the lamp power is automatically set so that the luminance is maintained. Lamp power
Luminance sensor value
Lamp power
Luminance sensor value
100
1000
100
800
90
800
90
600
80
600
80
400
70
400
70
200
60
200
60
0
CALIBRATE