Gamma & Uniformity Tool
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Support Functions
•Uniformity Adjustment •Adjustment Level •12.5%, 25%, 37.5%, 50%, 62.5%, 75%, 87.5% 100%
•Target Time of Adjustment •1 Hour
•Gamma (Gray Tracking: the 2.6th power) Adjustment •Adjustment Accuracy • x = 0.314 ± 0.002
, y = 0.351 ± 0.002
•Target Time of Adjustment •30 Minutes Copyright © Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Parts List Item
Model Name
Manufacturer
Sample price
1 Camera
XCD-SX910CR
Sony
420,000 (JPY)
2 Lens
DF6HA-1B
FUJINON
30,000(JPY)
3 Tripod Adaptor
VCT-ST70I
Sony
2,500(JPY)
4 Capture card or board
CFW-46(card)
42,000(JPY)
PFW-46(board)
Technoscope (Japan)
5 Color Meter
CL-200
Konika Minolta
289,000(JPY)
6 Cable of the Color Meter
T-A11
Konika Minolta
10,000(JPY)
7 Tripod 8 Software
--PCAT
Include AC Adaptor
42,000(JPY)
--Sony
Remarks
--Free
For the camera and the CL-200 Windows XP
PCAT means Projector Color Adjustment Tool. Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Parts Image 1. XCD-SX910CR 2. DF6HA-1B 3. Tripod Adaptor 4. Capture Card or Board 5. CL-200 6. Cable for the CL-200
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Preparation for PCAT(1/2)
screen
Camera
R220
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Preparation for PCAT(2/2)
Select how to connect with the Projector
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Gamma Adjustment(1/3)
Set COM Port No with the CL-200
Click Adjust Button
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Gamma Adjustment(2/3) screen When Click Adjust Button, Adjusting Window for CL-200 is appeared. Set the CL-200 to the window.
The Adjusting Window CL-200
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Gamma Adjustment(3/3) When CL-200 was set up the window, Click Yes button And start Gamma Adjust.
Gamma Adjustment requires about 30 [min]
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Uniformity Adjustment(1/4)
Click Adjust Button
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Uniformity Adjustment(2/4) Adjust the Camera position to frame. Adjust the focus of the camera Click Screen OK
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Uniformity Adjustment(3/4)
Start Button Adjust the iris of the camera How to adjust the iris of the camera is to accede to the message. And click Start Button.
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
Sony internal use only
Uniformity Adjustment(4/4)
Uniformity Adjustment requires about 60 [min]
Copyright Š Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.
How to buy •Please buy the camera, the tripod adaptor, the tripod and the CL-200 with cable directly from the manufacturer. •The lens and the capture board (card) are registered in WRPC. (If you can buy directly from the manufacturer, you may do it.)
Details are announced with Technical memo.
Copyright © Sony Corporation Digital Cinema Biz. Dept. 2007-2008 All Rights Reserved.