Measurement of Impulsive Thrust from a Closed Radio-Frequency Cavity in Vacuum

Page 1

JOURNAL OF PROPULSION AND POWER

Measurement of Impulsive Thrust from a Closed Radio-Frequency Cavity in Vacuum Harold White,∗ Paul March,† James Lawrence,‡ Jerry Vera,§ Andre Sylvester,¶ David Brady,** and Paul Bailey†† NASA Johnson Space Center, Houston, Texas 77058 DOI: 10.2514/1.B36120

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

A vacuum test campaign evaluating the impulsive thrust performance of a tapered radio-frequency test article excited in the transverse magnitude 212 mode at 1937 MHz has been completed. The test campaign consisted of a forward thrust phase and reverse thrust phase at less than 8 × 10−6 torr vacuum with power scans at 40, 60, and 80 W. The test campaign included a null thrust test effort to identify any mundane sources of impulsive thrust; however, none were identified. Thrust data from forward, reverse, and null suggested that the system was consistently performing with a thrust-to-power ratio of 1.2 0.1 mN∕kW.

Nomenclature a B c E F f f h nphoton q t U v x ϵ0 λ μ0 ρν

= = = = = = = = = = = = = = = = = =

II.

acceleration, m∕s2 magnetic field, T vacuum speed of light, m∕s electric field, V∕m force, N frequency, Hz force density, N∕m3 Planck constant, J · s number density of photons, number∕m3 elementary charge, C time, s electromagnetic energy density, J∕m3 velocity, m∕s position, m vacuum permittivity, F∕m average photon spacing, m vacuum permeability, N∕A2 vacuum density, kg∕m3

I.

Experimentation

A. Facilities

Introduction

I

T WAS previously reported that radio-frequency (RF) resonant cavities generated anomalous thrust on a low-thrust torsion pendulum [1,2] in spite of the apparent lack of a propellant or other medium with which to exchange momentum. It is shown here that a dielectrically loaded, tapered RF test article excited in the transverse magnetic 212 (TM212) mode (see Fig. 1) at 1937 MHz is capable of consistently generating force at a thrust-to-power level of 1.2 0.1 mN∕kW with the force directed to the narrow end under vacuum conditions. Received 28 November 2015; revision received 23 August 2016; accepted for publication 25 August 2016; published online Open Access 17 November 2016. This material is declared a work of the U.S. Government and is not subject to copyright protection in the United States. All requests for copying and permission to reprint should be submitted to CCC at www.copyright.com; employ the ISSN 0748-4658 (print) or 1533-3876 (online) to initiate your request. See also AIAA Rights and Permissions www.aiaa.org/randp. *Advanced Propulsion Theme Lead and Principal Investigator, Eagleworks Laboratories, EP4, 2101 NASA Parkway. Member AIAA. † Principal Engineer, Eagleworks Laboratories, 2101 NASA Parkway, EP4. Senior Member AIAA. ‡ Electrical Engineer, Eagleworks Laboratories, 2101 NASA Parkway, EP5. § Mechanical Engineer and COMSOL Multiphysics Analyst, Eagleworks Laboratories, 2101 NASA Parkway, EP4. ¶ Project Manager, Eagleworks Laboratories, 2101 NASA Parkway. **Aerospace Engineer, Eagleworks Laboratories, 2101 NASA Parkway. †† Scientist, Eagleworks Laboratories, 2101 NASA Parkway.

The thrust measurements were made using the low-thrust torsion pendulum at NASA Johnson Space Center. This torsion pendulum is capable of measuring thrust down to the single-digit micronewton level. Figure 2 shows a simple representation of the torsion pendulum’s major elements. The torsion pendulum is constructed primarily of an aluminum structure that is mounted on a slideout table within a 0.762-by-0.914 m vacuum chamber. The chamber is subsequently mounted on a 1.219-by-2.438 m optical bench. The pendulum arm pivots about two linear flexure bearings in a plane normal to gravitational acceleration. For every thrust measurement, a calibration force is provided by means of establishing a voltage potential across a set of interleaving aluminum electrostatic fins [3], with one set of fins on the fixed structure and one set on the pendulum arm. The fins overlap without touching. A calibration voltage is applied to the fixed structure fins, which induces a force upon the pendulum arm fins and an associated displacement that is measured by the system. The electrostatic fins design provides a constant electrostatic force over a reasonably large range (between 30 and 70% overlap, or a few millimeters of travel), so adjustments to the calibration mechanism between test-run data takes are usually not required. Calibration of the overlap/force relationship is accomplished using a Scientech SA 210 precision weighing balance (resolution to 1 μN). The displacement of the torsion pendulum is recorded by an optical displacement sensor, and the steady-state displacement from the calibration force is used to calibrate any force applied to the torsion pendulum by a device under test. The optical displacement sensor can be accurately positioned relative to the torsion pendulum by means of X-Y-Z micropositioning stages. Whenever a force is induced upon the pendulum arm, the resultant harmonic motion must be damped. This is accomplished via the use of a magnetic damper at the back of the torsion pendulum arm. Four neodymium (NdFeB grade N42) block magnets interact with the pendulum’s copper damper angle bracket to dampen oscillatory motion. The magnets are housed in a low-carbon steel square tube to better localize the magnetic field of the magnets in the damper and not in the chamber. Vacuum conditions are provided by two roughing pumps and two high-speed turbopumps, and all vacuum tests are performed at or below 8 × 10−6 torr. The high-frequency vibrations from the turbopump have no noticeable effect on the testing seismic environment. All dc power and control signals pass between the external equipment and vacuum chamber internal components via sealed feedthrough ports. Inside the vacuum chamber, all dc power and control signals that pass between the torsion pendulum fixed structure and the pendulum arm are transmitted via liquid metal contacts in order to eliminate interface cable forces. Each liquid metal contact consists of a physical but non-force-producing interface between a brass screw and a small socket filled with Galinstan liquid metal. The test article is mounted on the end of the pendulum arm

Article in Advance / 1


2

Article in Advance

/ WHITE ET AL.

closest to the chamber door. Test article support electronics (e.g., signal generators, amplifiers, phase adjusters) may be mounted on either end of the pendulum arm. If needed, ballast is added to the pendulum arm to eliminate moments that affect the neutral position of the pendulum arm. After a test article is mounted on the pendulum arm, a typical test-run data take consists of a prerun calibration (using the electrostatic fin mechanism), followed by energizing the test article, and finishing with a postrun calibration and data recording.

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

B. Test Article

Fig. 1 TM212 field lines in dielectric loaded cavity: red arrows represent electric field, and blue arrows represent magnetic field.

Fig. 2

The RF resonance test article is a copper frustum with an inner diameter of 27.9 cm on the big end, an inner diameter of 15.9 cm on the small end, and an axial length of 22.9 cm. The test article contains a 5.4-cm-thick disk of polyethylene with an outer diameter of 15.6 cm that is mounted to the inside face of the smaller diameter end of the frustum. A 13.5-mm-diam loop antenna drives the system in the TM212 mode at 1937 MHz. Because there are no analytical solutions for the resonant modes of a truncated cone, the use of the term TM212 describes a mode with two nodes in the axial direction and four nodes in the azimuthal direction. A small whip antenna provides feedback to the phase-locked loop (PLL) system. Figure 3 provides a block diagram of the test article’s major elements.

Simplified representation of torsion pendulum.

Fig. 3 Block diagram of integrated tapered test article: all components depicted are kitted together into an integrated test article that is mounted to the end of the torsion arm.


Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

Article in Advance

The loop antenna is driven by an RF amplifier that is mounted on the torsion arm with the test article. The signal from the RF amplifier is routed to the test article’s loop antenna through a dual directional coupler and a three-stub tuner. The dual directional coupler is used to measure the power forward to the test article and the power reflected from the test article. The three-stub tuner is used as a matching network to create a 50 Ω load as seen by the RF amplifier at the target drive frequency. In an ideally tuned RF resonance system, the power forward would be maximized, whereas the power reflected would be minimized using some form of control logic, be it manual or automatic tuning. The RF amplifier gets the input signal to be amplified from the PLL circuit. The PLL circuit is, in essence, the control electronics that reads the “echo” (ac electric field signal at actual resonance frequency) from the RF resonance system by means of the whip antenna; compares the echo to the drive signal using a mixer, determines the appropriate dc drive voltage for the voltagecontrolled oscillator (VCO) to ensure that the drive signal is properly matched to the echo in the system; and keeps the system on resonance, even though components get warmer and the geometry changes slightly due to thermal expansion shifting the resonance. All of the elements depicted in Fig. 3 are assembled into an integrated test article that is represented as the large conical object labeled “Test Article” in Fig. 2. Not shown in the block diagram for clarity are the signals from the control panel and instrumentation outside of the vacuum chamber. The “seed” frequency for the voltage-controlled oscillator located in the PLL box is determined by an external control voltage. In a sense, this provides the PLL with a “starting” frequency to then delta away from as necessary to keep the system in optimal resonance conditions within the bandwidth of the PLL. In this way, the test article can be resonated in any chosen RF resonance modes by setting this seed frequency close to a known resonance, and the system will “snap” onto and maintain resonance at the target mode. The power magnitude is established by providing a control voltage to a variable voltage attenuator that attenuates the output from the VCO that is then routed to the RF amplifier for amplification. The power forward and power reflected meters provide a dc signal proportional to the power reading, and they are routed to the laboratory data-acquisition rack for conversion and display to the operator. Optimal tuning: considerable time and effort were spent empirically studying and mapping out the optimal and nonoptimal RF tuning configurations for the TM212 mode to generate maximum thrust. One impetus for this effort was earlier observations in the laboratory that showed one could have an optimally tuned RF resonance system that could generate a large amount of thrust in one set of RF tuning conditions, as well as generate a small amount of thrust in another set of RF tuning conditions. In both cases, the system was an effectively tuned RF resonance system with a high-quality factor and low reflected power at runtime. The other impetus for this effort was that the model used to predict thrust performance for a given RF resonance mode, test article geometry, and dielectric loading showed that the force magnitude was highly nonlinear as a function of input power, suggesting that RF tuning for maximum thrust would have tighter constraints than just RF tuning for optimal RF resonance. AVCO, even though it is effectively a monosinusoidal source, still has some frequency jitter about the frequency set point. This jitter in practice can reduce the effective thrust as the system spends a small fraction of time at a slightly nonoptimal thrust configuration with a periodicity linked to the VCO’s frequency jitter. Also, the PLL may add some small offsets to the “locked” frequency center point. For the process of conducting this highly empirical system study, each tuning iteration would establish an RF tuning and operational condition for the integrated system. An Agilent Technologies FieldFox vector network analyzer (VNA) (part N9923A) was used to quantify the RF characteristics for the established resonance. The Smith chart for the system was used for initial tuning using the threestub tuner, a choice of loop antenna, and orientation of the loop antenna relative to the test article. The loaded quality factor was calculated for each RF tuning configuration to be tested. The change in phase angle over frequency was also calculated, and a new parameter dubbed the phase angle quality factor was developed to

/ WHITE ET AL.

3

help quantify the characteristics of a given resonance condition. The phase angle quality factor was the change in phase angle over a given frequency range, and it was determined using the phase plot from the VNA and only considering the region of the steepest phase angle change centered on the resonance. Figure 4 depicts a montage of plots from the VNA for a given set point. In the figure, the top-left pane is the log S11 plot that was used to calculate the loaded quality factor and any asymmetry to the RF resonance (upper side band compared to lower side band). The top-right pane is the Smith chart for the system, and the nomenclature “−j65” represents the angle of the line through the center of the system’s circle as it corresponds to complex impedance on the perimeter of the Smith chart. The bottom-left pane is the variation in phase angle for the system, and the bottom-right pane is the group delay. The tuning study determined that, for this particular tapered test article, optimal thrust was present if the system had a quality factor of at least several thousand and the maximum phase angle quality factor that could be achieved. In practice, this latter metric means the system is usually just slightly overcoupled, and the circle in the top-right pane of the figure will just encircle the center of the Smith chart (50 Ω point). C. Vacuum Campaign 1. Signal Superposition

Figure 5 shows a conceptual simulation of the superposition of an impulsive signal and a thermal signal (from thermal expansion of the system). The simulation is a simple mathematical representation of the combination of a signal with steady-state magnitude, quick rise/ fall times (impulsive content), and a logarithmic signal that increases while the impulsive signal is present and decreases when the impulsive signal is removed (thermal content). This figure shows a scenario where the magnitudes of the impulsive and the thermal are similar, and the polarities are the same. Inspecting the plot, one can see that the thermal signal creates a shifting baseline for the impulse signal. The evidence for the presence of the impulsive signal is the strong discontinuity of slope on the leading edge of the superposition trace. The relative magnitude of the impulsive signal can be determined by taking the lay or path of the superposition trace after this discontinuity and shifting it down so that the projection of this curve will intersect with the origin. This approximately detangles the impulsive thrust part from the thermal part. As can be seen from the plot, when the impulsive signal is terminated, the discontinuity of slope in the superposition trace can be very subtle, depending on the magnitude of the impulsive signal to the thermal signal. In this simulation case, the trailing-edge discontinuity is not detectable, whereas the leading edge is clearly detectable. The nature of the optical displacement signals collected during testing activities conducted under atmospheric conditions showed that the impulsive signal was much larger than the thermal signal, likely due to convection cooling precluding heat buildup. Testing under vacuum conditions showed an increase in thermal drift compared to atmospheric runs due to radiative cooling limitations, whereas the impulsive signal stayed the same. As a result, the thermal signal in the vacuum runs was slightly larger than the magnitude of the impulsive signal. Detailed thermal testing and analysis of the test article in air and under vacuum showed that the aluminum heat sink was the dominant contributor to the thermal signal. Figure 6 shows thermal imagery of the test article after a run, and the aluminum heat sink is the hottest surface in the posttest imagery. As the aluminum heat sink got warmer, its thermal expansion dominated the shifting center of gravity (CG) of the test article mounted on the torsion pendulum. This CG shift caused the balanced neutral point baseline of the torsion pendulum to shift with the same polarity as the impulsive signal when the test article was mounted in the forward or reverse thrust direction. Figure 7 shows a forward thrust run in vacuum conditions of the tapered test article operated in the targeted TM212 mode with an input power of ∼60 W. The characteristic discontinuity of slope was evident on the leading edge of the superposition trace from the optical displacement sensor. The characteristics of the curve after this discontinuity were used as the


Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

4

Article in Advance

/ WHITE ET AL.

a) Return loss

b) Smith plot

c) Phase

d) Group delay

Fig. 4 Data for a given RF configuration collected using an Agilent Technologies N9923A (4 GHz) FieldFox RF vector network analyzer: a) return loss as a function of frequency used to calculate the quality factor (dip in the plot denotes the resonance frequency); b) Smith chart for integrated test article used as a tuning guide, c) change in phase as the system moves through the resonance, used to calculate a phase quality factor; and d) group delay, which is an alternative way to see the resonance and quality of the RF system.

Fig. 5 Superposition of signals: conceptual superposition of an impulsive thrust (red) and thermal drift (green) signal over an on/off power cycle on the torsion pendulum.

baseline to be shifted down so that the line projects back to the “origin” or moment when RF power was activated. This was the technique used to assess all vacuum test runs, and it will be discussed in detail in the following section. 2. Force Measurement Procedure

This subsection will detail the step-by-step process used to take the optical displacement sensor data and quantify the magnitude of the impulsive force using the signal superposition approach. Figure 8 shows the same run from Fig. 7 with some additional annotations to the data. There are two major sections of the optical displacement

data that are tied to the impulsive calibration force (29 μN), and there is the center section that represents the response of the torsion pendulum system when the RF test article is energized with RF power. The raw data used to establish the “top” of the first calibration pulse, or left calibration pulse, include the two highlighted sections of raw data that include the data points with time ranges of 0 to 4.4 s, as well as 44.6 to 57.6 s. A line is fitted to the data, and the equation is shown above the highlighted data: 0.004615t 1249.360, where t is the variable time in seconds, 0.004615 has units of micrometers per second, and 1249.360 has units of micrometers. The raw data used to establish the “bottom” of the first calibration pulse include the highlighted section with a time range of 11.4 to 28.6 s. The equation of the line fitted to the data is shown below the highlighted data: 0.005095t 1248.367. The vertical separation between these two lines is determined at the middle of the first calibration pulse, which is ∼20.2 s on the time axis. The vertical separation between the top and the bottom of the first calibration pulse using the two fitted linear equations is 0.983 μm, which corresponds with the calibration pulse magnitude of 29 μN. The raw data used to establish the top of the second calibration pulse, or right calibration pulse, include the two highlighted sections of raw data that include the data points with time ranges of 155 to 158.6 s, as well as 178.8 to 184 s. A line is fitted to the data, and the equation is shown above the highlighted data: −0.07825t 1263.499. The raw data used to establish the bottom of the first calibration pulse include the highlighted section with a time range of 163.2 to 171.6 s. The equation of the line fitted to the data is shown below the highlighted data: −0.0827t 1263.163.


Article in Advance

/ WHITE ET AL.

5

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

Fig. 6 IR imagery of test article after testing: left pane shows RF amplifier and heat sink; middle pane shows phase-locked loop; and right pane shows copper test article. Imagery was taken by a Fluke Ti100 thermal imager.

this line is adjusted downward so that the line that represents the thermally shifted baseline will roughly intersect with the optical displacement curve where the RF power is turned on. This shifted baseline and its equation are shown on the plot: 0.13826t 1241.468. The vertical shift between the top of the impulsive force and the shifted baseline is 3.77 μm. The average vertical displacement of the two calibration pulses can be used to convert this vertical displacement number obtained from the shifted baseline to a force:

Fig. 7 Superposition of signals: test article run at 60 W in vacuum. The thrust rises slowly and peaks (break in slope) about 20 s after the RF power is initiated. Why is this not instantaneous? As will be discussed in more detail at the end of the section on slope filtering, in order to run the test article in a fully integrated configuration, the torsion pendulum is operated in a highly loaded configuration, which results in slower displacement rates for the torsion pendulum when an impulsive force is applied. Also note that, in the case of this 60 W forward thrust test under vacuum conditions, the power signal also has some power fluctuations after the amplifier is activated (the power is also shown in the figure). This power oscillation corresponds to the small bump in displacement, and the slope increases after the power oscillation is over.

Fig. 8 Force measurement procedure plot: the figure shows one of the 60 W forward thrust runs with the data annotated to indicate the sections used to determine the calibration pulse characteristics and the force pulse characteristics (Cal, calibration).

The vertical separation between these two lines is determined at the middle of the second calibration pulse, which is ∼167 s on the time axis. The vertical separation between the top and the bottom of the second calibration pulse using the two fitted linear equations is 1.078 μm, which corresponds with the calibration pulse magnitude of 29 μN. The raw data used to establish the top of the impulsive force from the operation of the test article include the highlighted section of raw data in the middle of the plot with a time range of 83.8 to 102.8 s. A line is fitted to the data, and the equation is shown to the left of the highlighted data: 0.13826t 1245.238. The vertical axis intercept (1245.238) to

F

29 μN × 3.77 μm 106 μN 0.983 μm 1.078 μm ∕2

(1)

The fitted linear equations are used to generate the dashed–dotted lines for the top and bottoms of the calibration pulses, the top of the impulsive force from the operation of the test article, and the shifted baseline in Figs. 7, 9, and 10. 3. Slope Filtering: Alternate Approach

In the process of developing, applying, and reviewing the signal superposition approach, a suggestion was provided by reviewers to implement and evaluate slope filtering of the optical displacement data. If the important distinction is that there is a change in slope indicating the presence of both thermal and impulsive signals, why not just take the derivative of the displacement signal and replot the curve, only showing changes that are greater than a specified level? This is done in Fig. 11 using an aggressive slope-filter level. Comparing the slopefiltered curve to the coplotted raw displacement data, the two sections of the curve that are known thermal-only portions of the curve have been filtered to horizontal in the slope-filtered curve (see time ranges of ∼80–100 s and ∼106–150 s). The characteristics of the second calibration curve after the test run are such that it has a large leading edge and small trailing edge to the pulse. This is a known impulsive signal that is present while there is also a significant thermal signal of same sense (negative-going). The characteristics of the curve while the RF power is applied to the test article are similar to this calibration pulse, which may be an indication that there is an impulsive signal present with a same-sense thermal signal while the test article is energized. The critical filtered displacement values for the first and second calibration pulses and the curve when the RF power is applied are annotated on the figure, and these values can be used to calculate a force magnitude. Using the numbers shown to calculate the average displacements for the two calibration pulses and calculating the average force pulse displacement, the predicted force magnitude using this slope-filtering technique is 124 μN. One thing that was observed when implementing this approach was that the filter value necessary to “flatten” the sections of the displacement curve that were known to be thermal only also resulted in the reduction in displacement magnitude for the leading calibration pulse, which was known to be a pure impulsive signal with no background thermal. A possible explanation for this was the fact that


6

Article in Advance

a) 40 W

/ WHITE ET AL.

a) 40 W

b) 60 W Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

b) 60 W

c) 80 W Fig. 9 Forward thrust, at vacuum, representative runs. Error bars ( 6 μN) are shown as black dotted lines. The three figures show a run at 40 W (top), 60 W (middle), and 80 W (bottom). The power is coplotted with the thrust trace. The calibration pulses are annotated based on the analysis of the optical displacement data. The signal superposition method is used to establish the magnitude of the impulsive thrust, and the results of the analysis are plotted on each figure.

the torsion pendulum was highly loaded with mass, making the inertial response time to impulsive forces only slightly faster than the thermal response, which meant there would be some loss of impulsive data during aggressive slope filtering. The current implementation with an integrated test article and all necessary support electronics assembled into a single integral package required a large amount of ballast to balance the pendulum arm, leaving the torsion pendulum highly loaded. This highly loaded scenario made the impulsive response time of the torsion pendulum considerably slower compared to the response times for previous tests in a “split configuration” mode. In the split configuration mode, the amplifier and supporting electronics were on the opposite side of the pendulum from the test article, which allowed this equipment to also serve as the ballast mass, cutting the overall mass on the pendulum arm by a factor of two compared to the integrated approach. Figure 12 shows both ends of the pendulum bar for a split configuration, with the test article on one end and the support electronics on the other end serving as the ballast. The response of the pendulum in the split configuration mode to an impulsive signal was considerably faster by comparison to the current approach. The bottom pane of Fig. 12 shows vacuum testing of the split configuration exciting the TM212 mode at 60 W. The calibration pulses had a magnitude of 29 μN. As discussed, and can be seen in the data, the inertial response time for this split configuration was quicker than the integrated approach. Also, the thermal contribution for the split configuration was smaller in magnitude compared to the impulsive signal, which made determination of the impulsive force magnitude an easier affair than the signal superposition approach that was used for the integrated test article implementation. The physical reason for this reduction in thermal contribution was likely due to the fact that the amplifier was on the back of the pendulum with the fins down and the amplifier on top, so thermal expansion of the aluminum heat sink only moved the amplifier mass up and did not drastically

c) 80 W Fig. 10 Reverse thrust, at vacuum, representative runs. Error bars ( 6 μN) are shown as black dotted lines. The three figures show a run at 40 W (top), 60 W (middle), and 80 W (bottom). The power is coplotted with the thrust trace. The calibration pulses are annotated based on the analysis of the optical displacement data. The signal superposition method is used to establish the magnitude of the impulsive thrust, and the results of the analysis are plotted on each figure.

Fig. 11 Slope-filtering plot with aggressive slope-filter level. The solid trace is the filtered data, and the dashed–dotted trace is the raw unfiltered data. The critical displacement values for the leading calibration pulse, force pulse, and trailing calibration pulse are annotated on the plot. Using these numbers yields a predicted force magnitude of 124 μN.

change the CG of the torsion pendulum arm in the horizontal plane. Future tests with the integrated test article approach will rotate the amplifier and heat sink such that it is in a similar orientation to this historical split configuration testing in an effort to reduce horizontal CG shift from thermal contributions. The disadvantage to the split configuration that led to its abandonment was that performing forward and reverse thrust testing required complete disassembly and reassembly of the RF system when switching thrust directions, which precluded the ability to establish a “frozen” RF tuning configuration, and was not compatible with the intention of performing force measurement testing at another location using another force measurement system. Also, as indicated in Sec. II.B, tuning the thruster to generate optimal thrust was very difficult, and breaking configuration when switching from forward to reverse thrust was not practical.


Article in Advance

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

a) Test article

7

/ WHITE ET AL.

b) Support electronics (as ballast)

c) 60W forward thrust run at vacuum for split configuration Fig. 12 Split configuration: The photographs show how the pendulum arm was loaded with the test article on one end and the support electronics on the opposite end, serving as ballast. The thrust trace illustrates the quicker rise times for the pendulum in response to an impulsive signal. 4. Force Measurement Uncertainty

The contributors to the force measurement uncertainty are identified and quantified. The conversion from optical displacement to a force measurement is dependent upon a number of factors. The calibration force is provided by means of an electrostatic fin design (discussed earlier) that was calibrated offline using a Scientech SA210 precision weighing balance with a measurement uncertainty of 0.0001 g or 1 μN. The calibration campaign of the fin design evaluates the performance of the electrostatic combs through a range of fin-engagement ranging from 10% engaged to 90% engaged. Based on this calibration campaign, the operational fin-engagement range is established to be from 30 to 70%, which provides roughly 3 mm of operational range, which is well beyond what is needed for this campaign. The uncertainty in force measurement for this fin-engagement range can be as high as 2.2 μN when the fins are at the edges of the operational range. The calibration voltage is provided by a Fluke 343A dc voltage calibrator, which has a voltage uncertainty of 0.004 V for a calibration voltage of 200 V, which corresponds to a force uncertainty of 0.0005 μN. The optical displacement reading is provided by a Philtec muDMS-D63 displacement measurement system with a positional uncertainty of 0.01 μm when running in the far mode at five samples per second. Based on the magnitudes of the calibration forces used during the vacuum campaign, this corresponds to a force measurement uncertainty of 0.4 μN (worst case). The seismic contribution to positional uncertainty during vacuum runs is 0.05 μm, which corresponds to a force measurement uncertainty of 2.2 μN (worst case). Seismic contributions can be larger in magnitude with a very low frequency on windy days due to waves in Galveston Bay and the Gulf of Mexico (see green run in Fig. 13), but this is operationally controlled by not performing vacuum tests during windy conditions. The placement of the thermally compensated baseline discussed in the previous section may have some level of uncertainty due to establishing the intersection point of the shifted baseline and the start of the test. It should be noted that the thermal

Fig. 13 Forward thrust green run, with ambient pressure conditions. Error bars are not provided for green runs.

baseline is assumed to be linear, which fits well with observed behavior. A conservative value of 0.2 μm is applied to this thermal uncertainty, which corresponds to a force measurement uncertainty of 4.5 μN (worst case). The root sum square of all of the measurement uncertainties yields a value of 5.6, which means the overall measurement uncertainty is 6 μN. Table 1 provides a tabulation of the measurement uncertainty contributions and the total measurement uncertainty.

Table 1 Measurement uncertainty tabulation Source Magnitude, μN SA210 1 Fin calibration 2.2 Fluke 343A 0.0005 muDMS-D63 0.4 Seismic 2.2 Thermal 4.5 Total error 6


8

Article in Advance

/ WHITE ET AL.

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

5. Forward Thrust Overview

The tapered RF test article was mounted on the torsion pendulum as shown in Fig. 14. Forward thrust was defined as causing displacement to the left in the photograph. Viewed from above, the torsion arm moved clockwise, causing the mirror attached to the torsion arm to move away from the optical displacement sensor, which appears as an upward motion or positive displacement in the plots of displacement vs time in Figs. 9 and 13. This displacement was also in the same direction as that due to the CG shift from thermal effects. A typical data run consists of 1) a leading calibration pulse, typically either 200 or 300 V equating to 29 or 66 μN, respectively, that lasts for a few seconds and is released; 2) the RF system energized for a period of time, ranging from dozens of seconds to well over 1 min; and 3) an identical trailing calibration pulse. All data are saved digitally and, immediately after the run, photographic evidence of the displays is also taken. During a run, the control and data acquisition system also records the power forward/reflected to/from the test article and the RF amplifier temperature inside the vacuum chamber. Before testing in vacuum, an initial green run (a green run is defined here as a trial run to confirm proper tuning) is performed at ambient pressure (see Fig. 13). As discussed earlier in Sec. II.C.1, the ambient pressure run shows considerably less thermal shift of the baseline and an almost entirely impulsive thrust pulse that exhibits similar millinewton-per-kilowatt performance as the vacuum impulsive thrust. The test article was run at 40, 60, and 80 W. Three runs were performed at each power setting for a total of nine vacuum tests in the forward thrust orientation. Once the system was at vacuum, the mixture ratio of impulsive signal to thermal baseline signal changed from the ambient, in that there was more thermal baseline shift apparent in the data. Using the analysis techniques discussed in the Force Measurement Procedure section (Sec. II.C.2), the shifting baseline and impulsive signal could be decoupled and a magnitude for the impulsive signal found. Figure 9 depicts thrust pulses representative of each power level used to collect statistical data. Table 2 shows a summary of the detected impulsive thrust from the forward thrust campaign conducted while the test article was under vacuum conditions (less than 8 μtorr).

Table 2

Run no. 1 2 3

Forward thrust results in vacuum conditions (in micronewtons)

40 W Power, Force, W μN 40.1 48 6 40.8 30 6 40.8 53 6

Power band 60 W Power, Force, W μN 60.6 106 6 59.7 91 6 61.4 128 6

80 W Power, Force, W μN 81.3 76 6 83.5 119 6 80.7 117 6

while transitioning between the 60 and 80 W runs (the stub tuner position was moved inadvertently). This required a retuning of the system and a repeat of an ambient pressure green run. Figure 16 shows the preliminary ambient pressure run performed before reverse thrust vacuum testing, as well as the repeated ambient pressure run performed after retuning the system between the 60 and 80 W testings. The test article was run at 40, 60, and 80 W. Three runs were performed at each power setting for a total of nine tests in vacuum conditions in the reverse thrust orientation. Figure 10 depicts thrust pulses representative of each power level used to collect statistical data. Table 3 shows a summary of the detected impulsive thrust from the reverse thrust campaign conducted while the test article was under vacuum conditions (less than 8 μtorr).

6. Reverse Thrust Overview

The tapered RF test article was mounted on the torsion pendulum as shown in Fig. 15. Reverse thrust was defined as causing displacement to the right in the photograph. Viewed from above, the torsion arm moved counterclockwise, causing the mirror attached to the torsion arm to move toward the optical displacement sensor, which appeared as a downward motion or negative displacement in the plots of displacement vs time in Figs. 10 and 16. As the test article assembly was rotated by 180 deg, this displacement was also in the same direction as that due to the CG shift from thermal effects. Aside from the pointing direction, the test procedure, power levels, data collection, and initial green run at atmosphere were performed identically to the forward thrust case. An additional event to highlight in this reverse thrust effort was that the system tuning was disturbed

Fig. 15 Reverse thrust mounting configuration.

a) Ambient run 1

Fig. 14 Forward thrust mounting configuration (heat sink is black finned item between test article and amplifier).

b) Ambient run 2 Fig. 16 Reverse thrust green runs, with ambient pressure conditions. Error bars are not provided for green runs.


Article in Advance

Table 3

Run no. 1 2 3

Reverse thrust results in vacuum conditions (in micronewtons)

40 W Power, Force, W μN 40.9 40 6 41.5 30 6 41.4 30 6

Power band 60 W Power, Force, W μN 60.2 43 6 60.2 83 6 59.1 67 6

80 W Power, Force, W μN 83.2 74 6 80 71 6 80 69 6

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

7. Null Thrust Overview

The tapered RF test article was mounted on the torsion pendulum as shown in Fig. 17. Null thrust parlance means that the test article was mounted to the torsion pendulum so that its major thrust axis was parallel to the torsion pendulum beam directed radially inward and unable to affect an impulsive thrust signal on the pendulum. The CG shift from thermal expansion caused a downward drift in the optical displacement sensor. This null thrust orientation allowed the investigation to quantify any mundane impulsive thrust signals present and associated with the operation of the integrated test article at full RF power. The null thrust testing campaign was undertaken at vacuum conditions, and there were three runs performed, operating the integrated test article up to 80 W or equivalent to the maximum power exercised during the forward and reverse thrust tests. Running at maximum power provided an upper bound on any impulsive systemic contribution to the detected thrust. Figure 18 depicts a representative null thrust test run at 80 W under vacuum conditions. The results from the null thrust testing showed no impulsive element in the collected data: only the thermal signal. 8. Error Sources

A list of possible error sources is provided and discussed: 1) The first error involves air currents possibly generating a false positive signal. The test article is tested in atmospheric conditions and under vacuum conditions. The impulsive thrust performance (in millinewtons per kilotwatt) is observed to be nearly the same. 2) The second error is RF interaction with the surrounding environment, which has the potential for possible RF patch charging on the walls of the vacuum chamber interacting with the test article to cause displacement of torsion pendulum. Leaking RF fields are kept very low by ensuring RF connections are tight and confirmed by measuring with an RF leakage meter (levels are kept below a cell phone RF leakage level). Any wall interaction needs to be a wellformed resonance coupling and, because of the high frequency, will be highly sensitive to geometry. Keeping the RF test article on resonance inside of the frustum volume requires a phase-locked loop system to maintain resonance as the test article expands during operation, so it is not likely that the RF test article can establish and maintain an effective external RF resonance. Testing is performed with the torsion pendulum slid out of the vacuum chamber, and an enclosure is built around the pendulum. Although this generates a similar force performance to that inside the chamber, the air currents make the quality of the signal poor. Although RF interaction with the

/ WHITE ET AL.

9

chamber is not viewed by the investigation team as a likely false positive, a future way to totally eliminate any concerns will be to test in a larger vacuum chamber. 3) The third error is magnetic interaction, which has the potential for a false positive resulting from dc currents in power cables interacting during test article operation with ambient magnetic fields (e.g., local Earth field, magnetic damper) to generate a torque displacement on the pendulum. All dc power cables are a twisted pair or twisted shielded pair to minimize magnetic interaction. The test article is tested in forward, reverse, and null thrust orientations, but dc power cable routing and orientation is the same for all three configurations (power cables come in from the top of the test article), meaning any false positives will be the same magnitude and polarity for all three tests. This is not observed during the test campaign. 4) The fourth error involves thermal expansion and contraction of items mounted on the torsion pendulum, which will shift the CG of the pendulum and result in an offset displacement that can be a false positive. As was discussed in the section on signal superposition (Sec. II.C.1), any false positives from thermal will have a slower displacement response time on the torsion pendulum when compared to an impulsive thrust signal similar to the calibration pulse. Further, the test article is mounted to the torsion pendulum by means of two 1∕4 –20 (0.250" diameter, 20 threads per inch) fasteners at the bottom of the entire assembly, so components of the test article assembly are free to thermally expand without constraint, resulting in a superposition of all thermal expansion sources being a curve that is uniformly logarithmic in nature with no discontinuities of slope. Said another way, since the test article is only constrained by two fasteners at the bottom, thermal expansion has no mechanical restraints relative to the CG of the torsion pendulum. The integrated thermal signal for the system should be a uniform thermal signal with no discontinuities. Thus, it is reasoned that any discontinuities in slope from the optical displacement sensor are a strong indicator of the presence of a nonthermal source of displacement. Although the performance of the impulsive signal under atmospheric and vacuum conditions is nearly the same, the magnitude of the thermal under vacuum conditions is much larger when compared to atmospheric conditions. To definitively rule out any residual concerns about thermal error sources, future test campaigns could employ a test apparatus capable of measuring small torques over much larger angular displacements. For example, a Cavendish balance approach properly designed to allow very large rotation angles such as 90, 180, or even 360 deg will not be susceptible to this type of thermal false positive. 5) The fifth error is vibration. False positives from vibration are not likely, as vibration will not generate a steady-state angular displacement of the torsion pendulum during operation. Contamination of displacement data from high-amplitude vibration is mitigated by the 1.219 × 2.438 m optical isolation table, and testing for the record is only performed on days where the ambient vibration levels still present during testing are of very low magnitudes compared to the displacements from test activities. 6) The sixth error is electrostatic interaction, which involves the potential for false positives from the charging of moving components of a torsion pendulum relative to the stationary components of a torsion pendulum and surrounding environment. All components of the torsion pendulum and the surrounding environment are held at a

Fig. 17 Null thrust mounting configuration.


10

Article in Advance

/ WHITE ET AL.

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

Fig. 18 Null thrust test run, at vacuum, with 80 W of power: shifting baseline due to thermal, with no impulsive content.

common reference ground by use of extensive grounding between components. This is confirmed with an ohm meter. 7) The seventh error is outgassing, which has the potential for a false positive from vaporization of surface molecules of the dielectric insert or other nonmetallic surfaces. During operation, the RF amplifier is the warmest component of the integrated test article. The RF amplifier is kept below 90°F for hardware life preservation, and this temperature is monitored by the supporting laboratory equipment. Infrared imagery during operation of the test article shows that the larger end of the cone is the warmest portion of the RF resonance volume, but it is less than the amplifier. The dielectric is mounted on the smaller end of the tapered volume. Any outgassing that might occur from the dielectric insert will be vented from the flat ends of the cone in an orthogonal, radial axisymmetric manner to the axis of the test article, which will not be detected as a rectified force by the torsion pendulum. Additionally, the force from outgassing being tied to thermal heating will likely have much slower rise and fall times when compared to the impulsive response from the calibration pulse. Said another way, outgassing will manifest as a slow increase in displacement (force) when the test article is active, as well as a similar slow decrease in displacement (force) back to zero after the test article is shut down and the system slowly cools down. 8) The eighth error photon rocket force, RF leakage from test article generating a net force due to photon emission. The performance of a photon rocket is several orders of magnitude lower than the observed thrust. Further, as noted in the above discussion on RF interaction, all leaking fields are managed closely to result in a high quality RF resonance system. This is not a viable source of the observed thrust. 9) The ninth error involves uncertainty in impulsive/thermal signal decoupling. Some vacuum thrust traces are unambiguous, and decoupling impulsive from thermal is straightforward. In cases where the magnitude of drift gets very large compared to impulsive, the process is more challenging. One step to improve any given run is to minimize runtime, as that keeps the drift magnitude lower. Another approach will be to reconfigure the integrated test article so that the RF heat sink is mounted in such a way that the thermal expansion is vertical as seen by the pendulum arm, thereby minimizing thermal contamination. As noted earlier, to definitively rule out any residual concerns about thermal error sources, future test campaigns could employ a test apparatus capable of measuring small torques over much larger angular displacements. 9. Synopsis of Experimental Results

Figure 19 presents a collection of all the empirically collected data. The averaging of the forward and reverse thrust data is presented in the form of circles. A linear curve is fitted to the data and is shown with the corresponding fitted equation. The vacuum test data collected show a consistent performance of 1.2 0.1 mN∕kW, which is very close to the average impulsive performance measured in air (also 1.2 mN∕kW). The error bars about the average data points represent a 2σ error. The error bars about the individual data points represent the force measurement uncertainty of 6 μN. 10. Discussion

Before providing some qualitative thoughts on the proposed physics potentially at work in the tapered RF test articles, it will be useful to

Fig. 19 Graph of forward and reverse thrust vacuum testing.

provide a brief background on the supporting physics lines of thought. In short, the supporting physics model used to derive a force based on operating conditions in the test article can be categorized as a nonlocal hidden-variable theory, or pilot-wave theory for short. Pilot-wave theories are a family of realist interpretations of quantum mechanics that conjecture that the statistical nature of the formalism of quantum mechanics is due to an ignorance of an underlying more fundamental real dynamics, and that microscopic particles follow real trajectories over time just like larger classical bodies do. The first pilot-wave theory was proposed by de Broglie in 1923 [4], where he proposed that a particle interacted with an accompanying guiding wave field, or pilot wave, and this interaction was responsible for guiding the particle along its trajectory, orthogonal to the surfaces of constant phase. In 1926, Madelung [5] published a hydrodynamic model of quantum mechanics by recasting the linear Schrödinger equation into hydrodynamic form, where the Planck constant ℏ was analogous to a surface tension σ in shallowwater hydrodynamics and vacuum fluctuations were the reason for quantum mechanics. In 1952, Bohm [6,7] published a pilot-wave theory where the guiding wave was equivalent to the solution of the Schrödinger equation and a particle’s velocity was equivalent to the quantum velocity of probability. Soon after, the Bohmian mechanics line of thinking was extended by others to incorporate the effects of a stochastic subquantum realm, and de Broglie augmented his initial pilot-wave theory with this approach in 1964 [8], adopting the parlance “hidden thermodynamics.” A family of models categorized as vacuum-based pilot-wave theories or stochastic electrodynamics (SED) [9] further explored the concept that the electromagnetic vacuum fluctuations of the zero point field represent a natural source of stochasticity in the subquantum realm and provide classical explanations for the origin of the Planck constant, Casimir effect, ground state of hydrogen, and much more. It should be noted that the pilot-wave domain experienced an early setback when von Neumann [10] published an impossibility proof against the idea of any hidden-variable theory. This and other subsequent impossibility proofs were later discredited by Bell 30 years later in 1966 [11], and Bell went on to say in the preface of his 1987 book [12] that the pilot wave eliminated the shifty boundary between wavy quantum states on the one hand and Bohr’s classical terms on the other: said simply, there was a real quantum dynamics underlying the probabilistic nature of quantum mechanics. Although the idea of a pilot wave or realist interpretation of quantum mechanics is not the dominant view of physics today (which favors the Copenhagen interpretation), it has seen a strong resurgence of interest over the last decade based on some experimental work pioneered by Couder and Fort [13]. Couder and Fort discovered that bouncing a millimeter-sized droplet on a vibrating shallow fluid bath at just the right resonance frequency created a scenario where the bouncing droplet created a wave pattern on the shallow bath that also seemed to guide the droplet along its way. To Couder and Fort, this seemed very similar to the pilot-wave concept just discussed and, in subsequent testing by Couder and others, this macroscopic classical system was able to exhibit characteristics thought to be


Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

Article in Advance

restricted to the quantum realm. To date, this hydrodynamic pilotwave analog system has been able to duplicate the double slit experiment findings, tunneling, quantized orbits, and numerous other quantum phenomena. Bush put together two thorough review papers chronicling the experimental work being done in this domain by numerous universities [14,15]. In addition to these quantum analogs, there may already be direct evidence supportive of the pilot-wave approach: specifically, Bohmian trajectories may have been observed by two separate experiments working with photons [16,17]. Reconsidering the double slit experiment with the pilot-wave view, the photon goes through one slit, and the pilot wave goes through both slits. The resultant trajectories that photons follow are continuous real trajectories that are affected by the pilot wave’s probabilistic interference pattern with itself as it undergoes constructive and destructive interference due to reflections from the slits. In the approach used in the quantum vacuum plasma thruster (also known as a Q thruster) supporting physics models, the zero point field (ZPF) plays the role of the guiding wave in a similar manner to the vacuum-based pilot-wave theories. To be specific, the vacuum fluctuations (virtual fermions and virtual photons) serves as the dynamic medium that guides a real particle on its way. Two recent papers authored by members of this investigation team explored the scientific ramifications of this ZPF-based background medium. The first paper [18] considered the quantum vacuum at the cosmological scale in which a thought experiment applied to the Einstein tensor yielded an equation that related the gravitational constant to the quantity of vacuum energy in the universe, implying that gravity might be viewed as an emergent phenomenon: a long wavelength consequence of the quantum vacuum. This viewpoint was scaled down to the atomic level to predict the density of the quantum vacuum in the presence of ordinary matter. This approach yielded a predicted value for the Bohr radius and electron mass with a direct dependency on dark energy. The corollary from this work pertinent to the q-thruster models is that the quantum vacuum is a dynamic medium and could potentially be modeled at the microscopic scale as an electron-positron plasma. The quantum vacuum around the hydrogen nucleus was considered in much more detail in the second paper [19]. Here, the energy density of the quantum vacuum was shown to theoretically have a 1∕r4 dependency moving away from the hydrogen nucleus (or proton). This 1∕r4 dependency was correlated to the Casimir force, suggesting that the energy density in the quantum vacuum is dependent on geometric constraints and energy densities in electric/magnetic fields. This paper created a quasi-classical model of the hydrogen atom in the COMSOL Multiphysics software (COMSOL is not an acronym) that modeled the vacuum around the proton as an electron-positron plasma. These analysis results showed that the n 1 to 7 energy levels of the hydrogen atom could be viewed as longitudinal resonant acoustic wave modes in the quantum vacuum. This suggests that the idea of treating the quantum vacuum as a dynamic medium capable of supporting oscillations might be valid. If a medium is capable of supporting acoustic oscillations, this means that the internal constituents were capable of interacting and exchanging momentum. If the vacuum is indeed mutable and degradable as was explored, then it might be possible to do/extract work on/from the vacuum, and thereby be possible to push off of the quantum vacuum and preserve the laws of conservation of energy and conservation of momentum. It is proposed that the tapered RF test article pushes off of quantum vacuum fluctuations, and the thruster generates a volumetric body force and moves in one direction while a wake is established in the quantum vacuum that moves in the other direction.

III.

Conclusions

A vacuum test campaign that used an updated integrated test article and optimized torsion pendulum layout was completed. The test campaign consisted of a forward thrust element that included performing testing at ambient pressure to establish and confirm good tuning, as well as subsequent power scans at 40, 60, and 80 W, with three thrust runs performed at each power setting for a total of nine runs at vacuum. The test campaign consisted of a reverse thrust

11

/ WHITE ET AL.

element that mirrored the forward thrust element. The test campaign included a null thrust test effort of three tests performed at vacuum at 80 W to try and identify any mundane sources of impulsive thrust; none were identified. Thrust data from forward, reverse, and null suggested that the system was consistently performing at 1.2 0.1 mN∕kW, which was very close to the average impulsive performance measured in air. A number of error sources were considered and discussed. Although thermal shift was addressed to a degree with this test campaign, future testing efforts should seek to develop testing approaches that are immune to CG shifts from thermal expansion. As indicated in Sec. II.C.8, a modified Cavendish balance approach could be employed to definitively rule out thermal. Although this test campaign was not focused on optimizing performance and was more an exercise in existence proof, it is still useful to put the observed thrust-to-power figure of 1.2 mN∕kW in context. The current state-of–the-art thrust to power for a Hall thruster is on the order of 60 mN∕kW. This is an order of magnitude higher than the test article evaluated during the course of this vacuum campaign; however, for missions with very large delta-v requirements, having a propellant consumption rate of zero could offset the higher power requirements. The 1.2 mN∕kW performance parameter is over two orders of magnitude higher than other forms of “zero-propellant” propulsion, such as light sails, laser propulsion, and photon rockets having thrust-to-power levels in the 3.33–6.67 μN∕kW (or 0.0033–0.0067 mN∕kW) range.

Acknowledgments The primary author would like to thank the Eagleworks team for support and hearty discussions about the concepts and testing discussed and explored in this paper. The primary author would also like to thank Andrew Chap for detailed and rigorous work to validate and optimize the plasma analysis tools. The team would like to thank NASA for organizational and institutional support in the exploration and analysis of the physics in this paper.

References [1] Brady, D., White, H., March, P., Lawrence, J., and Davies, F., “Anomalous Thrust Production from an RF Test Device Measured on a Low-Thrust Torsion Pendulum,” 50th AIAA/ASME/SAE/ASEE Joint Propulsion Conference, AIAA Paper 2014-4029, July 2014. doi:10.2514/6.2014-4029 [2] Tajmar, M., and Fiedler, G., “Direct Thrust Measurements of an EMDrive and Evaluation of Possible Side-Effects,” 51st AIAA/ASME/ SAE/ASEE Joint Propulsion Conference, AIAA Paper 2015-4083, July 2015. doi:10.2514/6.2015-4083 [3] Yan, A., Appel, B., and Gedrimas, J., “MilliNewton Thrust Stand Calibration Using Electrostatic Fins,” 47th AIAA Aerospace Sciences Meeting Including the New Horizons Forum and Aerospace Exposition, AIAA Paper 2009-0212, Jan. 2009. doi:10.2514/6.2009-212 [4] de Broglie, L., “Interpretation of Quantum Mechanics by the Double Solution Theory,” Annales de la Fondation Louis de Broglie, Vol. 12, No. 4, 1987, pp. 1–23. [5] Madelung, E., “Quantentheorie in Hydrodynamischer Form,” Zeitschrift für Physik A: Hadrons and Nuclei, Vol. 40, No. 3, 1927, pp. 322–326. doi:10.1007/BF01400372 [6] Bohm, D., “A Suggested Interpretation of the Quantum Theory in Terms of ‘Hidden’ Variables. I,” Physical Review, Vol. 85, No. 2, 1952, pp. 166–179. doi:10.1103/PhysRev.85.166 [7] Bohm, D., “A Suggested Interpretation of the Quantum Theory in Terms of ‘Hidden’ Variables. II,” Physical Review, Vol. 85, No. 2, 1952, pp. 180–193. doi:10.1103/PhysRev.85.180 [8] de Broglie, L., “La Thermodynamique « Cachée » des Particules,” Annales de l’I.H.P. Physique Théorique, Vol. 1, No. 1, 1964, pp. 1–19. [9] Boyer, T. H., “Any Classical Description of Nature Requires Classical Electromagnetic Zero-Point Radiation,” American Journal of Physics, Vol. 79, No. 11, 2011, pp. 1163–1167. doi:10.1119/1.3630939


12

Article in Advance

Downloaded by 80.100.41.226 on November 21, 2016 | http://arc.aiaa.org | DOI: 10.2514/1.B36120

[10] von Neumann, J., Mathematische Grundlagen der Quantenmechanik, Springer, Berlin, 1932. [11] Bell, J. S., “On the Problem of Hidden Variables in Quantum Mechanics,” Reviews of Modern Physics, Vol. 38, No. 3, 1966, pp. 447–452. doi:10.1103/RevModPhys.38.447 [12] Bell, J. S., Speakable and Unspeakable in Quantum Mechanics, Cambridge Univ. Press, Cambridge, England, U.K., 1987, p. xi. [13] Couder, Y., and Fort, E., “Single-Particle Diffraction and Interference at a Macroscopic Scale,” Physical Review Letters, Vol. 97, No. 15, 2006, Paper 154101. doi:10.1103/PhysRevLett.97.154101 [14] Bush, J. W. M., “The New Wave of Pilot-Wave Theory,” Physics Today, Vol. 68, No. 8, 2015, pp. 47–53. doi:10.1063/PT.3.2882 [15] Bush, J. W. M., “Pilot-Wave Hydrodynamics,” Annual Review of Fluid Mechanics, Vol. 47, No. 1, 2015, pp. 269–292. doi:10.1146/annurev-fluid-010814-014506 [16] Kocsis, S., Braverman, B., Ravets, S., Stevens, M. J., Mirin, R. P., Shalm, L. K., and Steinberg, A. M., “Observing the Average Trajectories

/ WHITE ET AL.

of Single Photons in a Two-Slit Interferometer,” Science, Vol. 332, No. 6034, 2011, pp. 1170–1173. doi:10.1126/science.1202218 [17] Mahler, D. H., Rozema, L., Fisher, K., Vermeyden, L., Resch, K. J., Wiseman, H. M., and Steinberg, A., “Experimental Nonlocal and Surreal Bohmian Trajectories,” Science Advances, Vol. 2, No. 2, 2016, Paper e1501466. [18] White, H., “A Discussion on Characteristics of the Quantum Vacuum,” Physics Essays, Vol. 28, No. 4, 2015, pp. 496–502. doi:10.4006/0836-1398-28.4.496 [19] White, H., Vera, J., Bailey, P., March, P., Lawrence, T., Sylvester, A., and Brady, D., “Dynamics of the Vacuum and Casimir Analogs to the Hydrogen Atom,” Journal of Modern Physics, Vol. 6, No. 9, 2015, pp. 1308–1320. doi:10.4236/jmp.2015.69136

G. G. Spanjers Associate Editor