ARCHITECTURAL WORKING DRAWINGS PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU ( NIG ) LTD
LOCATION
NO. 537 WUYE DISTRICT CADASTRAL ZONE B3
SEPTEMBER, 2020. GSPublisherVersion 0.1.100.100
GENERAL NOTES
Sheet Index Layout ID A.01.0 A.01.1 A.01.2 A.01.3 A.01.4 A.01.5 A.01.6 A.01.7 A.01.8 A.02.1 A.02.2 A.03.1 A.03.2 A.03.3 A.03.4 A.04.1 A.04.2 A.04.3 A.04.4 A.04.5 A.04.6 A.04.7
Layout Name Sheet index COVER SPECS SPECS SPECS SITE Ground Floor FIRST FLOOR SECOND FLOOR ROOF SECTION A SECTION B SOUTH ELEVATION WEST ELEVATION NORTH ELEVATION EAST ELEVATION DOOR SCHEDULE WINDOW SCHEDULE DETAILS DETAILS SOAK AWAY DETAIL 3D PERSPECTIVES 3D PERSPECTIVES
Revision
Issued
Published
Remark
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
ChID
Change Name
Date
Project Status:
Sheet Index
FOR CONSTRUCTION
1:0.65
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID SCALE: 1:0.65
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
1 PRELIMINARIES
1.04 - ITEMS SUPPLIED BY OWNER
Owner/s. Where possible, the engineer will certify that the
it is recommended that the owners/ is provided with a
Screw in foundations a proprietary brand flooring systems
1.01 - GENERAL
Items to be supplied by the Owner/s shall be identified in
site will support the proposed footings, slab and building
copy of master builders owners guide for terminate
based on co p e design with pre-cast beams and in situ
Owner/s - shall also mean Proprietor/s; Principal/s, the
the Addendum. Where it is agreed that additional items are
design.
management.
concrete e installed in accordance with the manufacture
person having the benefit of development consents to a
to be supplied by the Owner/s during construction, such
Costs of such consultation will be payable by the Owner/s
3.02 - VAPOUR BARRIERS
complying development certificate.
agreement and a description of the items shall be set out
as an additional cost not allowed for/or included in the
Vapour
Builder/s - shall also mean contractor/s.
in writing to the Builder.
contract sum, unless otherwise specified.
construction shall be in accordance with the international
Concrete paths shall be shown on the drawings and unless
Completion - shall mean Practical Completion.
It is the responsibility of the Owner/s to arrange payment,
1.13 - SITE IDENTIFICATION & SETTING OUT
building code.
otherwise specified, shall be at least 75mm thick and if
Proprietary - shall mean an item, product, material or
for delivery and protection against damage and theft of
The Builder is to visit the site and note the existing levels,
The vapour barriers shall be 0.2mm ,nominal thickness
unreinforced laid in sections not more n 1800mm in
colour identifiable by naming the manufacturer, supplier,
such items. All items, unless otherwise indicated in writing
site conditions and facilities. The Builder shall advise the
the polyethylene film of high impact resistance and
length. If reinforced, the maximum le of each section shall
trade name, brand name, and reference and/or catalogue
by the Owner/s shall be new and fit for their intended
Owner/s of any variation found at the site from the
branded continuously.
not exceed 3000mm.
number.
purpose.
documentation or information provided. The land shall be
3.0.3 - FORMWORK
Unless otherwise specified in the Addendum wood float or
Contract - shall mean the Conditions of Building Contract.
If items are not available when required, the Owner/s shall
block and peg surveyed and a survey certificate provided
Qualify formwork shall be used to provide shape, line
other non-slip finish shall be Provide falls away from the
barrier
installed
emendations and/or consulting Engineer. under
slab
–on
ground
3.11 - CONCRETE PATHS
All communication between Builder and Owner to be
be obliged to make an alternative selection.
before work commences. The cost of this survey shall be
true positioning and dimension to carry all imposed
buildin, 50 for 900mm. Slope concrete up and around over
copied to Architect. Builder shall be responsible for
1.05 - SITE ACCESS
included in the price unless otherwise specified. Any
loads. Brace sufficiently to prevent bowing or buckling
relief gullies and set inspection openings etc. flush with the
reviewing all notes prior to finalizing construction contract.
The Builder has statutory responsibilities in relation to
additional survey shall be subject to the allowance in the P.
while concrete is being poured and cure.
surface. Ensure weep-holes to adjacent structure are not
All construction and details shall be completed in full
Occupational Health and Safety. In order to assist the
C. Schedule
where the slab edge is to be exposed for termite
obstructed.
compliance with applicable local codes and requirements,
builder in maintaining a safe work site, the owner’s/ is
management , the exposed edge shall be off- the form
3.12 - TOLERANCES FOR CONCRETE FLOORS Shrinkage
including current handicap access and energy Title 24
agree to comply with any directions and instructions of the
2 EXCAVATIONS, FOUNDATIONS AND FOOTINGS
smooth and without honeycomb.
cracking cars be expected in concrete floors. Concrete
requirements.
Builder/s concerning site access and movement on and
2.01 - PROTECTION OF SERVICES
3.0.4 REINFORCEMENT
floors can also be damaged by foundation movement
Prior to finalizing contract prices, Contractor shall be
around the site.
Contact Dial-Before-You-Dig to identify the location of
Steel reinforcement shall comply with international building
caused by localized drying and wetting. The Builder is not
responsible for reviewing and coordinating all notes and
1.06 - SITE SIGN
underground assets (pipe work, service lines and network
code and the engineer’s details.
responsible for foundation movements caused by the
drawings to include any subcontract requirements or
Before work commences, the Builder shall provide a
installations).
Bar chairs shall be placed to give the following clear cover:
Owner/s failure to maintain drainage systems and the
information which may not be indicated on subcontractor's
signboard displaying the lot number, the Builder’s name,
2.02 - ENVIRONMENTAL
40mm to unprotected ground
overwatering and misuse of watering systems to gardens
sheets or notes, but which are indicated elsewhere in the
address and licence number.
2.02.1 - SOIL EROSION AND SEDIMENT CONTROL
30mm to a membrane in contract with the
located adjacent to slabs and footings.
construction documents.
The Architect is required to have a sign erected and
Measures shall be taken to manage the effects of storm
Verify all works, dimensions and details and report any
maintained on the site for the duration of the project which
water
sedimentation,
20 mm to an internal surface
4 RETAINING WALLS
discrepancies to the Owner and Architect prior to
provides their name and contact telephone number. The
contamination of the site, surrounding areas and drainage
40mm to external surface.
Retaining walls shall be constructed as identified
commencing work. During construction, the Owner and
sign should also state that Unauthorised Entry to the Site is
systems. Apply all site management requirements which
3.05 - PREMIXED CONCRETE
approved pans.
Architect are to be advised regarding any discrepancies in
prohibited.
are a Condition of Consent.
Premixed concrete shall be supplied to comply with
Retaining walls shall be constructed of a material or
measurement, dimension, location or a detail prior to
Information relating to the builder and the architect can be
2.02.2 - TREE PROTECTION
international building code. Concrete shall have default
proprietary system identified in the Schedule. Proprietary
builder’s proceeding with that portion of the work.
incorporated on a single sign.
Protect any tree/s identified for retention on the drawings
strength
retaining wall systems shall be constructed to the
Consult representatives of local utilities, including gas,
1.07 - SITE FENCING AND SCAFFOLDING
or as a condition of consent. Mark all trees and shrubs to
N20) and have a nominal aggregate size of 20mm
manufacturer’s requirements.
water, power, sewer, telephone and TV where applicable,
Unless otherwise stated, the Builder shall provide site
be retained with visible tape or other means. Where
unless otherwise specified , a default Slump of 100mm
The location of retaining walls to boundaries shall be
concerning locations and availability of utilities prior to
fencing to secure the site and scaffolding necessary to
necessary, provide physical barriers to protect marked
will apply to residential slabs and footings.
confirmed prior to construction.
commencing work or connecting utilities, and be
undertake the building work, including work undertaken by
trees and shrubs. Limit excavation within the drip-line.
3.06 - PLACEMENT
responsible for any damage to existing utility lines.
trade contractors engaged by the Builder.
The Owner/s shall advise the Builder of any vegetation
Trenches and footings shall be dewatered and cleaned
5 DRAINAGE AND WASTE WATER/SEWAGE TREATMENT
Provide as built drawings on the site plan showing
1.09 - SITE SERVICES & AMENITIES
protection orders related to the site.
of loose and softened materials prior to concrete
5.01 - GENERAL
horizontal locations dimensioned from face of building and
Temporary Toilet Accommodation: - shall be provided on
2.03 - SITE PREPARATION
placement
All drainage work shall be carried out by a licensed drainer.
vertical elevations based on finished floor of all existing
site until the completion of the works.
Rubbish, top soil and any vegetation within 1 metre of
3.07 - CURING
and new utility lines, mains, and meters. Deliver a
Water Supply: - unless otherwise specified and where no
proposed building/s shall be cleared and removed.
Concrete
reproducible copy to architect and owner upon completion
reticulated water supply is available to the site prior to the
2.04 - Excavation
sheeting, the application of suitable curing compound, by
5.02 - ONSITE WASTE WATER TREATMENT SYSTEM
of construction.
commencement of construction, the Owner/s shall supply
2.04.1 - SCOPE
keeping continually damp,
Wastewater onsite treatment systems shall be installed in
Confirm any discrepancies between drawings or
temporary water supply for use and as required at the
Excavate and backfill as required for all work shown on the
international building code.
accordance with the manufacturers’ requirements and the
specifications and job site conditions with Architect prior to
direction of the Builder.
drawings. The excavation and placement of fill shall be
Where adhesives to the slab surface in conjunction with
requirements
starting portions of the work affected.
Power: - unless otherwise specified, 240 volt power is to be
undertaken in accordance with international building code.
floor coverings are to be used strict care should be
commissioning of the onsite wastewater treatment system
No changes to the construction contract shall be permitted
supplied to the site for construction and associated
FOOTINGS
exercised in the use and compatibility of curing
the Owner/s will be responsible for the maintenance
without Architect's review. Written dimensions shall prevail
purposes. In the event power is not available and/or
Excavate trenches to engineers design or the approved
compounds.
requirements of the wastewater system provided.
over scaled dimensions on drawings. In no event is a
additional poles, service risers, underground wiring etc
footing design.
3.08 - FOOTINGS AND SLAB ON GROUND
dimension to be scaled off the drawings without prior
required by the Electricity Authority, this additional cost,
approval from Architect.
plus Builder’s margin shall be a cost to the Owner/s.
1.02 - STATUTORY REQUIREMENTS, APPROVALS, FEES AND INSPECTIONS
run-off
to
avoid
erosion,
at 28 days of not less than 20mpa (grade
DRAWING NOTES
shall be cured
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
ChID
or
with plastic
in accordance
with
of
the
Local
Authority
Following
the approval of the Achitect and the Principal Certifying
6.01 – MASONRY UNITS
1.10 - ON COMPLETION
3.01 - TERMITE RISK MANAGEMENT
Policy
Masonry units are to be as selected and as identified in the
The Builder upon completion will remove all surplus
Terminate Barriers shall be installed in accordance Prior
3.09 – PIER AND BEAM FOOTINGS
Schedule units produced from clay, concrete and calcium
All building and associated work shall comply with the
materials and construction debris from the site. The work
to the commencement of the work, the site shall be
Where nominated, pier and beam footings shall be
silicate shall comply with international building code.
relevant Acts & Regulations of Parliament and statutory
shall be cleaned throughout.
inspected or evidence of termite activity. where termite
constructed to the Engineers designed shall not be poured
Masonry units exposed to salt attack shall comply with
requirements.
1.11 - GEOTECHNICAL INVESTIGATION
nests are found on the site, treatment of the nests shall
without the approval of the engineer and the Principal
durability requirements.
1.03 - MATERIALS
An engineer qualified to investigate the soil conditions and
be carried out by a competent and qualified contractor
Certifying Authority.
6.02 - WORKMANSHIP
Materials shall be new, unless otherwise identified in the
classify the site in the area of the proposed building may
3.10 - SCREW IN FOUNDATION
Masonry construction shall comply with international
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
building code. Set out mansory as shown on the drawings,
Layout ID A.01.1 SCALE: 1:1.25
GSPublisherVersion 0.1.100.100
Date
with the international building code.
6 MASONRY
SPECIFICATIONS 1:1.25
Change Name
Storm water drainage shall be carried out in accordance by covering
Concrete slabs and footings shall not be poured without
be engaged by either the Builder or the
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
ground
3. CONCRETE
schedule
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
build to gauge to masonry units, maintain chosen bond
otherwise identified in respect of stress grade. Sizes of
not provided directly under an internal tie-down or bracing
base of the verandah posts shall be supported by
used they must be compatible in accordance with
with full mortars to a nominal 10mm. Mortar joints shall be
timber for constructional purposes to be the nominal size
wall provide noggin or bridging between adjacent joists at
galvanised shoes, stirrups or similar supports.
international
to the type nominated in the Schedule. Where the schedule
mentioned with allowable tolerances as provided by
all required fixing points.
7.14 - EAVES SOFFIT
recommended by the manufacturer of the sheet material
nominates raked joints, the rake must not extend into
international building code. Scantlings to be in long
7.6 - FLOORING
Where overhang is less than 600mm support linings on
to be joined.
reveals and sills beyond the line of the storm moulds.
lengths, accurately cut and fitted and securely fixed.
7.02 - ENGINEERED TIMBER PRODUCTS
45mm x 32mm soffit bearers at not more than 450mm
9.04 - BATTENS
The cleaning of masonry should take place as work
7.02 ENGINEERING TIMBER PRODUCTS.
7.06.1 - STRIP FLOORING
centres. Where overhang is between 600mm and not more
Roof battens may be of timber or steel.
progresses and upon completion in a manner so that the
In addition to any structural grade requirements, all
Flooring is to be clear finished and shall not be laid until
than 1500mm support soffit linings on 70mm x 35mm
Timber battens shall be sized and installed in accordance
work is not damaged. Pressure cleaning and acid wash
exposed wood beams and posts shall be selected for best
the building is weather tight. Check supplier certificate for
soffit bearers at not more than 450mm centres.
with international building code. Where battens are joined
should not be carried out without the prior; approval of the
appearance grade, with a minimum of knots, cracks and
species, grade size and moisture content prior to laying.
7.15 - CROSS VENTILATION
in a run, they shall be butt jointed at the centre of the truss
Builder where masonry is to be pressure cleaned, the
checks.
Where machine nailing is to be used, ensure boards are in
Ventilate the roof space at the ridge, gable and/or eaves to
or rafter.
following restrictions shall apply:
All exposed wood beams, decking or other members
contact with the joist as this type of nailing cannot be relied
effectively cross ventilate the whole of the roof space.
Metal battens shall be corrosion resistant and fixed to the
Maximum pressure shall be 7000 kpa; Use a wide fan
installed prior to enclosing the building envelope and
upon to pull board down to joist.
7.16 - HOT WATER STORAGE TANK SUPPORT
manufacturer’s recommendations. Metal battens are to be
spray nozzle of 150 to 200;
completing roofing membrane shall be protected during
All fitted floors require a 12mm expansion gap between the
Where solar water heaters incorporating a roof storage
joined over trusses with a minimum lap of 40mm. Advice
Nozzle shall be no closer to the work than 300mm.
construction against moisture, staining and other damage
floor boards and any internal or external wall structures.
tank are installed, ensure additional loading has been
should be obtained from the manufacturer on the use of
6.03 - MORTAR
by protecting with weatherproof plastic wrappers and
7.06.2 - PLYWOOD STRUCTURAL FLOOR
incorporated into the roof design.
metal battens in high corrosive areas.
Mortar mixes shall comply with international building code
additional protective measures as may be required.
Structural plywood must be manufactured in accordance
and may be mixed in volume. Mortar shall consist of a
All exposed framing shall be free from nicks, splinters, saw
with AS/NZS 2269 and sheet with the manufacturer’s
8 STEEL FRAMING
Flashings
mixture of cement, sand and water, with the addition of
marks and other imperfections.
name or trade mark Sheets shall be installed
8.01 - GENERAL
international building code. Lead flashings must not be
lime and admixtures. Where water thickener is used, it
All roof beams and supporting posts shall be anchored to
accordance with AS 1684, Plywood face grain ’’run at right
Steel framing will comply with Part framing shall be in
used with aluminum or zincalume roofing or rainwater
shall be cellulose-based product, suited for its application
provide resistance against uplift per structural drawings.
angles to the joists and shall be continued over at least
accordance with international building code.
plumbing, or anywhere where water supply is by rainwater
according to the manufacturer’s and supplier’s directions.
7.03 - HANDLING AND STORAGE
two spans. Where possible, pan ‘Sis shall be staggered.
The frame is to be assembled with fixings as per the
storage.
Mortar for reinforced masonry shall be of mortar class
Timber and timber products delivered to the site shall be
7.06.3 PARTICLE BOARD FLOORING
design, or
9.07 – GUTTERS AND DOWNPIPES
either M3 or M4.
stored at least 150mm off the ground, stored level, evenly
shall be laid and fixed in accordance with AS 1860.2
recommendations.
Gutters and downpipes shall be designed and installed in
6.06 - LINTELS
supported, well ventilated and protected from the rain and
Sheets shall span not less than two floor joist Square
CORROSION PROTECTION
accordance with international building code. Where high
Brick work over openings may be supported by steel lintel,
sun. Pre-fabricated trusses should be handled in a vertical
edges and ends of sheets shall by buj joists and trimmers
The steel frame must be protected from corrosion in
front gutters are installed, attention is required to prevent
reinforced masonry lintel or reinforced concrete member
position to avoid distortion and overstressing of the timber
7.07 - WALL FRAMING
accordance with international building code. Hole cutting
overflow back into the roof or building.
complying with AS 3600. Where steel lintel are used over
and connecting plates. Where pre-fabricated roof trusses
Wall frame, sizes and spacing shall be in accordance with
or cutting of members should be done in a way which does
openings, they shall be hot dip galvanized mild steel angles
are
international building code or as specified by a practicing
not leave swarf. Compatible material and fixings to be used
10 INTERNAL LININGS
or flat bars complying international building code. For
intermediate support. Do not site repair damaged trusses
engineer
to avoid galvanic or chemical action. Direct contact with
10.01 - WALLS
lintels with a clear span of 1 m or more, each end of the
and report them to the truss fabricator immediately to
7.08 - WALL SARKING
treated timber is to be avoided. For slab on ground, use
Walls shall be fixed in accordance with the manufacturer’s
lintel is to have a minimum bearing length of 150mm. For
avoid delays in rectification.
Provide wall sarking as noted on the drawings and/or
damp-proof course under wall frame bottom plate to
recommendations.
shorter spans the minimum end bearing is to be 100mm.
7.04 - CORROSION PROTECTION
noted in the Schedule. Provide vapour permeable sarking
prevent corrosion.
plasterboards of 10mm thickness to all internal walls,
Revision History
Not less than three (3) courses of brick must be used
All connectors, fixing plates, brackets and general fixings
.jnder cladding material that does not provide a permanent
The frame is to be permanently earthed. Channels should
except as required for wet areas, or other type of panelling
RevID
above steel lintels and brickwork shall not overhang the
and related components shall suit exposure level and be
weather proof seal (such as unpainted fibre cement, sawn
be clean of any swarf and mortar droppings.
as indicated in the Schedule and plans.
lintel by more than 25mm. Prop lintels until mortar has
compatible to avoid galvanic or electro-chemical action.
weatherboards). Fix sarking on the outside of the studs
Electrical wiring, water pipes and their services passing
10.02 - WET AREA LININGS
reached its design strength. Props should be no more than
7.05 - FLOOR FRAMING
from the bottom plate (lapped over flashing if any) up to at
through the frame are to be isolated from it by rubber
Wet area linings shall be of water instant maternal for full
1 .2 meters apart. The long leg of angle lintels must be
All floors not specified to be concrete are to be framed at
least the level o the underside of the fascia. Allow a gap at
grommets or other suitable material.
wall height in accordance with international building code.
vertical.
the level shown. Floor structure sizes and spacing are to be
the top plate for wall ventilation. Timber Stairs Timber
6.09 – CLEARANCES
in accordance with international building code or otherwise
stairs are to be designed and constructed to riser, going
9 ROOFING (TILES AND METAL)
Ceiling linings shall be 13mm gypsum plasterboard or
In masonry construction generally leave the following
specified by a Practicing Structure engineer. Bearers, joists
and balustrade dimensions and in accordance with
9.01 - GENERAL
10mm high—density; plasterboard be set as required
clearances between window frames and brick sills and the
and plates shall be laid true and level.
international building code.
All roof cladding shall comply with international building
11 WATERPROOFING
roof structure and masonry veneer: 5mm at sills of lower or
7.05.1 - BEARERS AND JOINTS
7.10 - ROOF TRUSSES
code and one or more referenced documents relevant to
11.01 -GENERAL
single storey windows; 8mm at roof overhangs of single
Span and spacing of bearers & joists is to conform to
Roof trusses shall be fabricated in accordance with
the work:
From the drawings, identify the areas to be waterproofed
storey buildings; 10mm at sills to two storey buildings;
Standards in conjunction with supporting supplements
designs prepared by a practicing structural engineer.
Ensure appropriate fall prevention requirements are
Waterproofing to internal wet areas and balconies over
12mm at roof overhangs of two storey buildings.
relevant to the applicable wind classification and stress
7.11 - ROOF BRACING
installed prior to the commencement of roofing work.
habitable areas shall be in accordance with international
Clearances should be increased to accommodate expected
grade.
Provide
9.02 - ROOF TILES
building code.
timber shrinkage e.g. unseasoned hardwood.
7.05.2 - BLOCKING
manufacturer’s detail.
Provide roof tiles as shown on the drawings. Roof tiles shall
11.02 - WATERPROOFING SYSTEM SELECTION
6.10 - TOLERANCES IN MASONRY CONSTRUCTION
‘Where the depth of floor joists is equal to needs 4 times
7.12 - ACCESS TO ROOF SPACE
be of a colour, profile and material noted in the Schedule.
The waterproofing system should be selected according to
Masonry work is not considered defective if it is within the
their width, herringbone strutting blocking must be
Where the space between the roof and ceiling exceed
Roof tiles shall be fixed in accordance with the
the
following tolerances:
provided between the outer of joists and between
900mm in height, trim as required between roof trusses
international building code and referenced Standard and
specification, taking account of product suitability, and
intermediate pairs of joist not more than 1 .8 m centres, or
for a manhole, line the opening and provide a suitable
the nominated design wind speed for the project.
compatibility with surface materials
7 CARPENTRY
continuous trimmed js can be provided to the ends of joists
cover.
9.03 - METAL ROOFING
11.03 - COMPATIBILITY OF MATERIALS
7.01 TIMBER GENERALLY.
above wearers or wall plates.bTrimmers or solid blocking
7.13 - VERANDAH POSTS
Provide metal roofing as shown on the drawings. Metal
The waterproofing is to ensure component to component
All timber used shall be of the durability and stress grade
25mm less in depth than the joists and solid king shall be
Verandah posts unless otherwise specified shall be a
roofing shall be of a profile and color as provided in the
compatibility.
specified and/or comply with the international building
a minimum thickness of 25mm.
minimum of 100mm x 100mm or as required by
Schedule. Metal roofing and accessories shall be installed
11.04 - FLOOD TESTING
code. All structural timber used will be of a durability class
7.05.3 - JOISTS UNDER WALLS
international building code, checked at the top plat and
to the manufacturer’s recommendations. Metal roofing
On completion and after the membrane has fully cured,
appropriate to the expected service life and exposure
Provide double joists under all external walls running
secured to the floor structure. Where fixed to concrete the
must
floor waste outlet should be sealed and the area flooded
conditions. All structural timber used will be stamped or
parallel with the floor joists under the wall. Where a joist is
required
SPECIFICATIONS 1:1.25 GSPublisherVersion 0.1.100.100
to
be
handled
horizontally,
provide
roof
bracing
in
accordance
with
in
truss
building
code.
Use
only
sealants
9.05 - ROOF FLASHINGS
in accordance
with
the
manufacturer’s
shall
be
installed
Provide
in
accordance
with
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
recessed
edge
gypsum
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
ChID
Change Name
Date
10.03 - CEILING LININGS
be
corrosion
resistant
in
accordance
with
international building code. Where different metals are
project
requirements
and
the
manufacturers’
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.01.2 SCALE: 1:1.25
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
with water floor water leaks. The height of water should be
Provide kitchen cupboards as included on the drawings
rating listed in UPC Table 5-1. All hot water heaters shall be
Where location of PV modules is not shown on the plan, it
16.03 - PREPARATION
5mm below the overflow level of the water stops
and/or included in the Schedule. Kitchen cupboards and
strapped to wall as required by applicable codes.
will be the responsibility of the accredited installer
All surfaces shall be prepared to the manufacturer’s
11.05 - PROTECTION
bench tops shall be fabricated from water resistant
Wrap storage type water heaters and storage and backup
undertake an onsite assessment and identify the precise
product recommendations. Final preparation shall be the
Membrane area shall be protected by barriers or signage
materials.
tanks for solar water heating systems with minimum R-12
location for the modules. The assessment is to identify any
responsibility of the painter/applicator.
the membrane is fully cured.
12.10 - LINEN/STORAGE CUPBOARDS
insulation exterior and R-16 for interior.
overshadowing or other influence which may affect the
16.04 - SPRAYING
If shown, to be constructed as detailed on the drawings.
Install an insulated hot water recirculating system on a
operation of the installation. A Certificate of Compliance
pray application to plasterboard is to be ‘back rolled” floor
timer to within 10'-0” of all fixtures, with pump and aquistat
for electrical work is to be issued upon completion and
surfaces are to be tiled, ensure floor surface is protected
commissioning of the work.
from overspray.
12 JOINERY
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
12.01 - GENERALLY
13 PLUMBING
locations at the hot water heater.
All fixing out timber to be s o and free from defects which
13.01 – GENERAL
13.04 – STORM WATER DRAINAGE
might affect appear durability. All timbers are to be
Except as provided by Architect in the Construction
Unless otherwise noted or required by code, all
15 WALL AND FLOOR TILING
The contractor shall remove empty paint tins and
accurate cut and securely fixed. Mouldings and trim are to
Documents, Contractor shall design, prepare necessary
underground storm drain lines shall be PVC min. Schedule
15.01 - GENERAL
associated waste from site and is to ensure the clean-up of
be properly mitered or scribed. All surfaces must be free of
plans, have plans checked, obtain and include price for
40 and min. 100mm diameter or greater as required to
Provide wall and tiles as shown on the drawings and/or
equipment does not contaminate the site.
machine marks and ready for painting. External joinery to
plumbing permits for all plumbing systems and equipment.
handle load. All connections shall be properly joined and
included in the Schedule.
removed for painting, all fittings, door furniture, switch
be inherently durable and primed prior to fixing.
Secure necessary approvals and reroute any existing utility
sealed so that they are water-tight.
15.02 - SURFACE PREPARATION
plates and the like to be re-fixed or re-installed, Paint
12.02 – DOOR FRAMES
lines, conduits or equipment in conflict with new
13.05 - SANITARY PLUMBING AND DRAINAGE
All tiling substrates shall be dry and free of dust, debris and
splashes, runs and drips are preferably to be removed
Door frames shall be solid rebated frames, packed plumb
construction and confirm rerouting with Architect, and note
Sanitary plumbing and drainage shall be undertaken in
deposits.
during use of the work or removed and repaired upon
and true and fixed securely to door opening studs or
such rerouting on the record drawings.
accordance with the Architect and the requirements of the
Very smooth trowel finishes on slabs; with slabs
Completion.
masonry. Metal door frames shall be installed to
13.02 - WATER SERVICE
Regulator or Local Authority. Sanitary plumbing and
inadequately cured, releasing agent and curing compounds
PRIME COST ALLOWANCES, PROVISONAL SUMS and
manufacture’s recommendations.
Unless otherwise specified, All new water supply lines shall
drainage work shall be undertaken by an appropriately
can lead to tile adhesion problems. Care should be taken
CONTINGENCY SUMS.
12.03 – DOORS
be copper and all new and accessible existing hot water
licensed person.
where there is paint overspray on floors adjacent to walls.
Provisional Sum (PS) is an item which includes supply and
External doors are to be solid core or framed and glazed
lines shall be insulated with R-4 or greater pipe insulation
All exposed angles, traps, drains, etc. shall be provided in
The preparation of smooth trowel floors and floors which
installation. Prime Cost (PC) sum is used for the supply only
and not less than 2040 x 820 x 40mm thick. Front and
with vapor barrier. No soft copper lines permitted.
the same finish as the specified plumbing fittings for that
are contaminated should be undertaken in consultation
of a specified item, excluding any associated labor
rear external doors shall be hung with three 88mm (mm)
All underground copper lines shall be Type L.
particular fixture. These items shall be considered to be
with the builder, tile and adhesive supplier and/or
Contingency (C) sum is an allowance for the supply of labor
butt hinges of suitable finish and durability. Where external
Copper lines shall have insolation couplings where
included in the rough plumbing costs and shall not be
manufacturer. Adhesive manufacturers’ recommendations
and materials related to unforeseen which is necessary to
doors are sheeted with plywood, only waterproof plywood
connecting to existing galvanized iron or steel pipe which
included in the plumbing fixture/ fitting costs.
on surface preparation should be followed.
progress complete the works.
which is to be used. Top and bottom door edges are to be
cannot be changed to copper.
13.07 - GAS
15.03 - COMPATIBILITY
painted or similarly sealed prior to hanging.
Main water line to domestic system shall be installed with
All gas-fitting work is to be installed and connected in
Ensure
Internal doors shall be not less than 35mm thick fitted with
separate gate valve and pressure regulator at house entry
accordance with the supply authorities’ requirements. Gas
waterproofing
suitable furniture and be installed with a clearance off the
point.
plumbing shall be provided as detailed on the plans and to
membranes to be properly cured prior to tile laying. Tile
floor of 30mm unless otherwise specified. Double doors
Hose bibs and irrigation systems except, at roof decks,
all fixtures requiring gas service from the point of supply.
adhesives, primers and related products must be
and sliding doors to be installed where shown on the
shall not be connected to building water system, but shall
Test all pipe work before concealment and securely fix pipe
compatible. The use of mixed brand products is not
drawings. Doors shall swing in the direction shown on the
be fed from main water line before building system
work to prevent movement. In-ground gas lines shall be
recommended. Selections of tile adhesives in wet areas
drawings.
pressure regulator and main valve.
identified with plastic warning tape 300mm above and for
are to be made in consultation with the builder, floor tile
Revision History
12.04 - WINDOWS
All hose bibs must have an approved anti-siphon device.
the full length of the line while backfilling.
and adhesive supplier and/or manufacturer.
RevID
Aluminium and timber windows shall be manufactured and
CPC 603.3
installed in accordance with code Windows are to be
All hot and cold shower and tub supply lines shall be
14 ELECTRICAL
Movement joints are to be provided as required by the
supplied with Performance label attached confirming
minimum 3/4" and water system shall be designed to
14.01 - GENERAL
code
compliance with code. Windows shall be protected from
assume full capacity of 3/4” pipes.
All electrical work shall be undertaken by a licensed
mortar droppings.
Provide a 12” minimum access panel to bathtub trap
electrician and in accordance with required code. A
12.05 - GLAZING
connection unless plumbing is without slip joints. Verify
Certificate of Compliance Electrical Work shall be provided
over movement joints in the substrate; and
Glazing in exterior doors or within forty inches of any
location with Architect prior to rough plumbing.
at the completion of the electrical work. Confirm the
In large tiled areas, immediate movement joints
locking mechanism shall be of fully tempered glass or
Provide individual control valves of the pressure balance or
position of the meter box. Single-phase power is to be
rated burglary-resistant glazing, except when double
the thermostatic mixing valve type for showers and tub
provided unless otherwise noted in the Schedule. Install all
cylinder deadbolt locks with a key retaining feature are
showers.
lights, power outlets and electrical fixtures nominated in
15.05 - FALLS IN WET AREAS
installed.
Provide ultra flush water closets (1.6 gallon/flush),
the Schedule.
Grade floor tiles to floor wastes and required.
12.06 - STM MOULDS
showerheads (2.5 gpm) and faucets (2.5 gpm) for all new
14.02 - SMOKE ALARMS
The recommended ratio of fall within 1:6Oandl:80. The
Provide storm moulds to external doors and other
construction. Existing showerheads and toilets must be
Smoke alarms shall be installed in accordance with
recommended ratio of fall in other wet areas is between
openings.
adapted for low water consumption.
international building code. Photo-electric smoke alarms
1:80 and 1:100.
12.07 – ARCHITRAVES
13.03 - HOT WATER SERVICES
should be the preferred type for installation in the path of
Provide architraves to all window, door am openings where
An approved water heater to be installed in accordance
travel between sleeping areas and exits.
16 PAINTING
necessary and of a as identified in the Schedule.
with the manufacturers’ instruction.
14.03 - SOLAR PV
16.01 - GENERAL
12.08 - SKIRTINGS
All C.E.C. certified, rapid recovery, sized to provide
Installation must be compliant with international building
All paint and related products such as primers, sealers and
Provide skirting where required of a type, finish and size as
adequate volume of hot water to fixtures served, and
code. Grid connect inverters shall comply required code.
fillers shall be compatible, suitable for purpose and used in
identified in the Schedule. Note: where skirting is to be
installed on smitty pans with concealed drains to exterior.
Solar panels are to be installed by either the licensed
accordance with the manufacturer’s recommendations and
fixed over tiled floors, the skirting shall not be fixed down
Heater drains and T & P valves shall be positioned and
builder or licensed electrician. All electrical wiring and
the manufacturer’s safety data sheets.
hard on the tile. so as to restrict the movement joint.
extended to drain into smitty pan. The minimum capacity
connections of solar PV system must be undertaken by an
16.02 COLOUR SELECTION.
12.09 - KITCHEN CUPBOARDS
for water heaters shall be in accordance with the first hour
appropriate licensed electrician, Meters are installed by an
Unless specified elsewhere, colours are to be selected by
Authorized Service Provider
the owner and shown in the Schedule.
SPECIFICATIONS 1:1.25 GSPublisherVersion 0.1.100.100
16.05 - COMPLETION
tile
adhesives
are
membranes
compatible used,
with
the
waterproofing
Where
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
ChID
Change Name
Date
15.04 - Movement Joints
Separate the tiled elements from fixed elements such as walls and columns;
at evenly spaced locations at approximately 4.5metres.
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.01.3 SCALE: 1:1.25
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
9,120
100
1,970
1,000
100
100
31 10,5
35,000
5,6 72
2,669
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
100
100 1,344 100 1,400
1,665 4,008
100
100
1,000
900
1,000
100 600
6,400
6,400
6,400
6,400
6,400
6,400
6,400
6,400
930
14,000
6,021
100
2,056
3,000
18,932
04 14,000
16,370
20,919
03 37,185 R 600
R 600
100
R 600
100 1,350
2,985
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
R 600
R 600
2,170
R 600 1,000
R 645
5,716
R 600
1,470 100
01
100
R 600
3,185
2,985
3,185
2,985
3,185
2,985
3,272
83
930
100
1,970
Revision History
R 1,464
ChID
Change Name
Date
4,500
5,806
RevID 9,4 09
N
DRAWING NOTES
02
4,767
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
100
7,770
100
6,4 74
6,070
1,000
1,000
100 1,000
12,539
5,170
900
1,000
R 1,464
9,706
4,679
1,500
10,220
16,390
22,560
28,817
31,900
4,500
R 1,464
21,395
6,005
4,500 6,582
2,596
12 3,7
Project Status:
R 1,464
4,3 70
5,116
FOR CONSTRUCTION
4,22 9
21,266
4,177
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
W-01
GSPublisherVersion 0.1.100.100
SITE PLAN
1:250
Layout ID A.01.4 SCALE: 1:250
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
N A.03.3
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
A.02.2 B1
Y1
24,910 6,170 1,677 230
6,170
1,563
1,200
793
2,930
900
465
900
482
1,677 1,200
230
6,170
1,563
1,200
793
2,930
900
465
900
482
1,677 1,200
230
6,400
1,563
1,200
793
2,930
900
465
900
482
1,677 1,200
230
1,563
1,200
793
2,930
900
465
900
482
1,200
W2
230 2,700 1,500 1,000 150 230
14,000
1,500 1,500
D1 W3
230 920
865
600 1,563
4,750
600
600
600
600
2,930
865
520
2,139 1,677
1,650
200 200 246 200 600 1,563 4,520
600
600
865
380 450
2,930
1,677 1,650
A.02.2 B1
GROUND FLOOR 1:125
865
600 1,563 4,520
24,910
S A.03.1
610
1,200
600
600
2,930
865
520
4,000 1,677
1,650
1,563 4,520
185
600
2,930 1,650
Project Status:
FOR CONSTRUCTION
19,700 300 1,200 300 1,200
300
W3
+150
230
1,200
W3
1,050
W3
1,200
2,170
450
+150
300
300 1,200
W3
1,200
W3
1,200
W3
W3
1,270
W4
F: 400mmX400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
E A.03.4
9,685 W3
300
6,060
W4
W3
Date
246
D1
W3
1,200
D3
W3
F: 400mmX400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
F: 400mmX400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
D1
B7 #LayID
PORCH W4
PORCH
+600
Change Name
A A.02.1
A: 2 m
F: 400mmX400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
PORCH
ChID
2
D1
230
W4
1,200
D3
230 1,570
230 1,570 230 2,170
A: 2 m2
+600
09
300 1,200
230 +600
09
RevID
A: 2 m2
+600
PORCH
300
WC
4 3 2 1
UP
4 3 2 1
UP
4 3 2 1
UP
WC
A: 2 m2
5,870 WC
09
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 27 m2
09
230
D3
4,516 20R x 180 19G x 251
4,516
WC MAIN LIVING ROOM
8 7 6 5
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 27 m2
2,700
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 27 m2
11
WC
680
MAIN LIVING ROOM
9
1,490
RE
F
FRIDGE
UP
2,560
Revision History
1,500
230
8 7 6 5
10
1,200 300
2,700
1,500
680
9
20R x 180 19G x 251
1,500
13
1,500
1,200
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 27 m2
1,505
12
160 11
4 3 2 1
13
1,200
20R x 180 19G x 251
D2
B7 #LayID
230
230
3,400
230
MAIN LIVING ROOM
9 8 7 6 5
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
9 8 7 6 5
1,500
F
1,500
209 1
246
3,150
14
DOWN
14
1,200
20R x 180 19G x 251
D2
230
14
11
209 1
19,700
WC
F
11 10 15
10 15
N
DRAWING NOTES 1,524
RE
FRIDGE
12
DOWN
15,200
14 13
10
1,677
GSPublisherVersion 0.1.100.100
15
DINING F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 10 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 10 m2
+600
15
230
DINING F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 10 m2
DINING
230
2,700
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 10 m2
12
2,560
230
1,200
RE
BATH
13
750
0.
3,010
DINING
F: 300X300mm CERAMIC TILE WF: CERAMIC TILE WHB A: 3 m2
1,000 150
RE
6,024 1,500
F: 300X300mm CERAMIC TILE WF: CERAMIC TILE A: 3 m2
230
D3
1,500
5,794
BATH
2,700
1718 16
D3
F: 300X300mm CERAMIC TILE WF: CERAMIC TILE WHB A: 3 m2
D3
+600
F: 400X400mm TILE WF: 200mmX600mm CERAMIC TILE GAS HOB P.O.P C: 15mm APPROVED PATTERN 01 A: 17 m2
BATH
230
1718 16
X18
3,010
1718 16
X17
230
KITCHEN
1718 16
X16
2,700
D2
230
F: 400X400mm TILE WF: 200mmX600mm CERAMIC TILE GAS HOB P.O.P C: 15mm APPROVED PATTERN 01 A: 17 m2
F: 400X400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
MAIN LIVING ROOM
X15
F: 300X300mm CERAMIC TILE WF: CERAMIC TILE WHB A: 3 m2
D3
D2
3,010 KITCHEN
2,700
BQ
X11
X14
BATH
F
230
12
X13
D3
FRIDGE
2,700
SINK
230
+600
X12
F: 400X400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
WC
1,500
1,500 1,524
3,010
F: 400X400mm TILE WF: 200mmX600mm CERAMIC TILE GAS HOB P.O.P C: 15mm APPROVED PATTERN 01 A: 17 m2
BQ
D2
209 1
1,500
1,500
W2
D1
X5
A A.02.1
F: 400X400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
DOWN
1,490
W2
X10
F: 400X400mm TILE WF: 200mmX600mm CERAMIC TILE GAS HOB P.O.P C: 15mm APPROVED PATTERN 01 A: 17 m2
BQ
D2
KITCHEN
X4
D-04 STAIRS GROUND FLOOR
F: 400X400mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
1,500
W2
D1
X9
BQ
D2
KITCHEN W2
X3
X7
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
1,500
1,500
W2
D1
209 1
1,500
W2
X2
X8
D2
DOWN
1,500
D1
X6
230
W3
X1
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
865
Layout ID A.01.5 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
N A.03.3
Y2
Y3
Y4
Y5
Y6
Y7
A.02.2 B1
Y1
75
Y9
Y10
Y11
Y12
Y13
24,935
2,015
4,080
1,677 75
Y8
521 450
1,563 1,044
2,090 2,930
545
4,080
1,677
3,000
635
1,563
230 266 450
1,044
2,090 2,930
545
4,080
1,677
3,000
635
230 266 450
1,563 1,044
2,090 2,930
545
3,000
4,410
1,677 635
230 266 450
1,563 1,044
2,930
545
3,000
635
230
900 BATHROOM
WHB
SHOWER
D2
15
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 20 m2
1,430
BATHROOM
230
01
300
A: 4 m2
230
2
A: 2 m 1,440
1,500 4,940
4,270 W1
13
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 20 m2
A: 2 m2
W1 W4
BAL. 13
A: 2 m2
13
270 230 1,000
1,500
BAL.
D1
230
W4
A: 2 m2
535
300
W1
270
1,200
1,500
X18
900 65
W1
X17
595
450
1,490
1,670 1,670
3,000 1,570
865 2,930
4,730
365 450 1,677 1,440
625
916
3,000 1,563
814
520
2,930
100 1,677
4,730
1,440
E A.03.4
20,700
230
W1
BAL.
SHOWER
3,740
1,200
X16
4,270
BEDROOM
+4,200
+4,200
SHOWER 1,440 230
A: 4 m2
2,470
F: 150X1200mm TILE WF: 200mmX600mm CERAMIC TILE
X15
01
4,940
BATHROOM
B7 #LayID
WHB
230
D1
230
300 1,200
X14
F: 150X1200mm TILE WF: 200mmX600mm CERAMIC TILE
D2
X13
2,840
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 20 m2
WC
D-07 STAIRS FIRST FLOOR
BEDROOM
3,050
100
1,563
2,400 2,930
4,730
1,440 1,677 1,440
230
635
3,000
1,563
635 2,930
4,730
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
A.02.2 B1
1. GSPublisherVersion 0.1.100.100
FIRST FLOOR
1:125
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT
230
FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
24,910
S A.03.1
Date
A A.02.1
1,500
230
Change Name
1,500
13
D2
1,440
ChID
W4
BAL.
D1
D2
230
4 3 2 1
230
230
246
D2
BEDROOM
F: 150X1200mm TILE WF: 200mmX600mm CERAMIC TILE
RevID
1,730
D2
UP
SHOWER
BATHROOM WC
2,840
D2 300X600X8MM UNGLAZED VITRIFIED TILE FLOOR FINISH
A: 4 m2
230
1,500
4 3 2 1
4 3 2 1
UP
WC A: 4 m2
01
2,870
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 20 m2
01
8 7 6 5
WHB
BEDROOM
F: 150X1200mm TILE WF: 200mmX600mm CERAMIC TILE
8 7 6 5
WHB
Revision History
1,500
20R x 180 19G x 251
9
4 3 2 1
9
UP
1,200
X12
BATHROOM
D2
5,205
WHB
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
1,200
20R x 180 19G x 251
+450
UP
B7 1,660 #LayID
230
9 8 7 6 5
11
4,516
4,516 20R x 180 19G x 251
10,500
1,500
X11
20R x 180 19G x 251
230
3,610
230
246 1,500 11,515
209 1
11
8 7 6 5
11
10
12
10
9
10
12
DOWN
A A.02.1
1718 16
13
13
F: 600X600mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 22 m2
+4,200
209 1
14
FAMILY LOUNGE
11 10
12
F: 600X600mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 22 m2
1718 16
15
14
13
FAMILY LOUNGE
DOWN
1,500
14
209 1
15
12
DOWN
1,515
SHOWER
1718 16
20,700
D2
15
13
F: 600X600mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 22 m2
F: 300X300mm TILE WF: 200mmX600mm CERAMIC TILE C: 15mm APPROVED PATTERN P.O.P
D1
150
14
FAMILY LOUNGE
BATHROOM
300
A: 6 m
230
F: 600X600mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 22 m2
100 300 270 230 230 1,000 100 1,000 230
230
D2
2
FAMILY LOUNGE
15,970
5,940
1,500
230
5,205
3,950
1,500
230
1,200
1,760
300
230
1,200
3,950
300
1,760 230 BATHROOM
WHB
1,200
230
N
DRAWING NOTES
WC
F: 300X300mm TILE WF: 200mmX600mm CERAMIC TILE C: 15mm APPROVED PATTERN P.O.P
+4,200
X9
1,524
SHOWER
D2
4,805
3,950
D2
A: 6 m2
01
SHOWER
1,500 1,500 230
WC
WC
WC
1,490
D2
A: 6 m2
01
+4,200
01
5,135
D1 D2
D1
01
F: 300X300mm TILE WF: 200mmX600mm CERAMIC TILE C: 15mm APPROVED PATTERN P.O.P
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 19 m2
D1
230
BATHROOM
WHB
1718 16
865 187
1,485
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 19 m2
F: 300X300mm TILE WF: 200mmX600mm CERAMIC TILE C: 15mm APPROVED PATTERN P.O.P
BEDROOM
5,035
937
+4,200 1,760
X8
X10
BEDROOM
W4
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 19 m2
W4
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
W4
BEDROOM
D1
3,185
1,960
BALCONY
A: 6 m2
X7
BALCONY F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
W4
X6
BALCONY F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
100
1,490 3,085
1,524
X5
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 19 m2
D2
910
1,500 100 1,400 100
W1
W1
X4
BEDROOM
D2
X3
BALCONY F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
1,170 230
1,270
230
X2
1,500
1,500
1,500
W1
209 1
X1
DOWN
1,600
W1
Layout ID A.01.6 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
N A.03.3
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
3,000
1,677
1,100
970
968
1,563
1,100
5,202
2,930
3,000
1,677
2,070
970
1,563
1,100
5,200
2,930
3,000
1,677
1,100
970
1,100
3,000
1,500
W3
761
2,130
739
+7,800
W3
761 739
509
W3
W3
E A.03.4
11,670 1,500
Project Status:
FOR CONSTRUCTION 1,500
761 W3
739
W3
LEAD INNOVATIVE ARCHITECTURE 1,500
W3
+7,800
W3
Date
A A.02.1
509
W3
+7,800
W3
Change Name
1,200 W3
739
+7,800
+7,800
W3
ChID
+7,800
W3
D1
+7,800
F: 300X300mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
RevID
+7,800
W3
BALCONY
Revision History
1,500
F: 150X1200mm TILE WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P VITRIFIED TILE 01 FLOOR FINISH A: 25 m2
5,830
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 25 m2
21,609
1,500 11,440 1,500
F: 150X1200mm TILE WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P VITRIFIED TILE 01 FLOOR FINISH A: 25 m2
X18 509
1,524
WHB
MASTER BEDROOM 4,270
230
F: 300X300mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
MASTER BEDROOM
D1
230
B7 #LayID
D1
MASTER BEDROOM
4,430
1,490 600 900 342 1,466
1,440
F: 300X300mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
MASTER BEDROOM F: 150X1200mm TILE WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P VITRIFIED TILE 01 FLOOR FINISH A: 25 m2
F: 300X300mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 7 m2
1,534
673
W3
D1
230
BALCONY
W3
428
4,270
W3
BALCONY
600
230
1,200
300
X17
1,200
4,200
300
X15
240
BALCONY
W3
900 141
300 1,200
X14
1,200
D2
1,200
X13
D-09 STAIRS SECOND FLOOR
230
246
527
1,500
1,713
W3
X12
230
W3
+7,800
1,140
+7,800
X11
4,270
D2
+7,800
D2
1,440 230
300
1,200
230
1,200
160
2,010
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
300
1,200
230
1,200
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
LOBBY
1,500
230
+7,800
300
2,010 CLOSET
3,700
1,200
150 1,140 230
230
D2
WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
CLOSET
LOBBY
2,400
1,200
6,790
160
WC
+7,800
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
D1
B7 D2 #LayID
246 1,500
1,200
2,010
+7,800
D2 D2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
CLOSET +7,800 F: 150X1200mm TILE
LOBBY
230
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
LOBBY
WHB
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
3,700
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
+7,800 CLOSET
D2
N
DRAWING NOTES
D2
D2
300X600X8MM UNGLAZED VITRIFIED TILE FLOOR FINISH
D2
BATHROOM 230 2,010 230
1,200
D2
300X600X8MM UNGLAZED VITRIFIED TILE FLOOR FINISH
W3
150
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 5 m2
BATHROOM
F: 150X1200mm TILE WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P UNGLAZED VITRIFIED 01 TILE FLOOR FINISH A: 5 m2
WHB
2,350
2,600
WC WHB
11,900
1,500
21,209
BATHROOM
BATHROOM
F: 150X1200mm TILE WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P UNGLAZED VITRIFIED 01 TILE FLOOR FINISH A: 5 m2
BATHROOM
WF: MATT EMULSION 300X600X8MM C: 15mm APPROVED PATTERN P.O.P UNGLAZED VITRIFIED 01 TILE FLOOR FINISH A: 5 m2
300X600X8MM UNGLAZED VITRIFIED TILE FLOOR FINISH
WHB
WC
BATHROOM
A: 5 m2 F: 150X1200mm TILE
D2
BATHROOM D2
WC WHB
WHB
W4
D1
230
W4
450
WC
BATHROOM D2
SHOWER
19
WC
WHB
W4
D1
W3
BATHROOM
D2
A A.02.1
W3
W4
W3
D1
230 4,200
4,660
WC
SHOWER
SHOWER
1,915
900
1,100 1,000 500 500
1,490 1,524 1,440
W A.03.2
W4
W4
1,560
+7,800
SHOWER
+7,800
A: 4 m2
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
WC
SHOWER
300X600X8MM VITRIFIED TILE FLOOR FINISH
22
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 23 m2
A: 4 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 23 m2
W4
+7,800
22
BEDROOM
BEDROOM
SHOWER
X16
300X600X8MM VITRIFIED TILE FLOOR FINISH
BALC.
W1
300X600X8MM VITRIFIED TILE FLOOR FINISH
A: 4 m2
F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 23 m2
SHOWER
X10
A: 4 m2
+7,800
22
BEDROOM
W4
X9
22
BALC.
W1
X6
X8
BALC. F: 150X1200mm TILE WF: MATT EMULSION C: 15mm APPROVED PATTERN P.O.P 01 A: 23 m2
BALC.
X7
1,200
BEDROOM
X4
X5
1,100
W1
1,000
1,500 1,500
X3
2,930
W1
500
900
1,600
1,500 1,500
X2
1,200
1,563
400
1,200
5,200
2,930
500
970
1,563
100 400
A.02.2 B1
5,300
1,677
X1
Y13
25,010
5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT
535
600 1,677 1,670
535
865
600
600
600
1,563
600 2,930
4,730
600
865 305
600 1,677 1,440
535
865
600
600
600
1,563
600
600
865 305
2,930
600 1,677
4,730
1,440
535
865
600
600
600
1,563
600 2,930
4,730
600
865 305
600 1,677 1,440
1,400
600
600
600
1,563
600
600
865 300
2,930 4,730
300
FOR
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
25,210
A.02.2 B1
S A.03.1
2.
GSPublisherVersion 0.1.100.100
SECOND FLOOR 1:125
DAN YARO AUDU (NIG) LTD
Layout ID A.01.7 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
N A.03.3
Y2
Y3
Y4
Y5
Y6
Y7
A.02.2 B1
Y1
Y8
Y9
Y10
Y11
Y12
Y13
518
5,422
230
5,652
518
5,652
934
518
5,652
518
5,652
484 450
X4
635
Slope 5deg
X5
507 11,670
X8
N
DRAWING NOTES
B7 #LayID
21,793
21,793
X7
21,793
3,902
X6
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
5,103
Slope 5deg
6,048
Slope 5deg
X2
X3
321 284 293 292 282 282 245 275 276 282 272 282 179
Slope 5deg
450
X1
E A.03.4
230
518
21,802
5,422
5,652
450 374
228
518
4,650
5,652
374
25,324
228
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History
X9
Slope 5deg
609 891 609 891 891
609
609 891
X17
891
X16
609
450
X15
891
B7 #LayID
X14
609
609
X18
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
1,210 1,450
4,730 5,180
230
990 220 990
4,730
230
5,180
990 990
4,950 5,180
230
990 990
4,950
230
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
460
Date
A A.02.1
609
X13
Slope 5deg
X12
Change Name
3,699
Slope 5deg
X11
ChID
6,061
Slope 5deg
2,243 510
X10 A A.02.1
RevID
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE
5,180
B3 ABUJA
25,140
A.02.2 B1
S A.03.1
3.
GSPublisherVersion 0.1.100.100
ROOF
1:125
Layout ID A.01.8 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
25mm Guage Stone Coated Ridge Cap. 25mm Guage Stone Coated Roofing Sheet 50X75mm Well Seasoned Termite Treated Hardwood Purlins @ 350 C/C 50X150mm Well Seasoned Termite Treated Hardwood Rafters @ 1200mm C/C 50X150mm Well Seasoned Termite Treated Hardwood King Posts @ 1200mm C/C
Y1
Y2
Y3
Y4
Y5
Y6
Y7
50X150mm Well Seasoned Termite Treated Hardwood struts @ 1200C/C 50X150mm Well Seasoned Termite Treated Hard Wood Tie Beam @ 1200mm C/C
Y8
Y9
Y10
Y11
Y12
Y13
200 100 300 426 600 469 443 184
443 184 896
443 184 896
CLOSET
+11,400 3 ROOF
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
W3
D2
D2
+7,800
BEDROOM
+7,800 2 SECOND FLOOR
+7,800
BEDROOM
BALCONY
12,900
2,400 150
D2
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
2,400
1,050
3,200 150
D2
+4,200
150
+4,200
MAIN LIVING ROOM
3,450
3,450
+4,200
150
150
MAIN LIVING ROOM
MAIN LIVING ROOM
ChID
Change Name
Date
+4,200 1 FIRST FLOOR
Approved Pattern Fully Architraved Purpose Made Security Door in Steel Frame
Project Status:
+600
450 150
450 150
+600
450 150
750 1,620
MAIN LIVING ROOM
W3
3,450
3,450
1,080 150
+4,200
450 150
D2
1,050
150
150 750 1,620
FAMILY LIVING ROOM
D2
2,400
D2
3,600
3,600
BALCONY
D2
1000mm High Stainless Steel Handrail
1,080
100
300
443 184 896
Approved Pattern Plaster of Paris (P.O.P) Suspended Ceiling Deco. to Arc.'s Later Spec.
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
+600 0 GROUND FLOOR
-900 -1 FOUNDATION
Approved Tile Finish on 50mm Thick Cement/ Sand Floor Screed On 150mm Thick Reinforced BRC Oversite Concrete Slab on 2 Layers of Damp Proof Membrane
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE
450mm Well Compacted Hardcore/ Laterite Back Fill 450X230X230mm Hollow Sandcrete Block Foundation Wall Filled Solid with Weak Concrete Foundation to Structural Engineer's Details and Spec.
A
GSPublisherVersion 0.1.100.100
Building Section
1:125
B3 ABUJA
Layout ID A.02.1 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
25mm Guage Stone Coated Ridge Cap. 25mm Guage Stone Coated Roofing Sheet 50X75mm Well Seasoned Termite Treated Hardwood Purlins @ 350 C/C 50X150mm Well Seasoned Termite Treated Hardwood Rafters @ 1200mm C/C 50X150mm Well Seasoned Termite Treated Hardwood King Posts @ 1200mm C/C
X1
X2
X3
X4
X5
X6
X7
X8 X9
X10
50X150mm Well Seasoned Termite Treated Hardwood struts @ 1200C/C 50X150mm Well Seasoned Termite Treated Hard Wood Tie Beam @ 1200mm C/C X11
X12 X13
X14 X15
X16 X17
X18
Approved Pattern Plaster of Paris (P.O.P) Suspended Ceiling Deco. to Arc.'s Later Spec. D-01 Detail
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES +11,400 3 ROOF +10,650 BEDROOM
W3
BATHROOM
STAIR HALL
BALCONY
D2
D1
D1
W3
Approved Pattern 1000mm High Stainless Steel Handrail
+7,800
+7,800
+7,800
+7,800 2 SECOND FLOOR
Revision History
D-03 Detail BALCONY
BATHROOM
D1
BATHROOM
D2
D2
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
BALCONY
D2
D1
+4,200
1.4mm Thick Aluminium Alloy Casement Window with 5mm Thick Tinted Glass
RevID
ChID
Change Name
Date
+4,200 1 FIRST FLOOR WC
KITCHEN
D2
D-02 Detail
D3
PORCH
D1
Project Status:
FOR CONSTRUCTION +600
+450
+600 0 GROUND FLOOR
-900 -1 FOUNDATION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT
Approved Tile Finish on 50mm Thick Cement/ Sand Floor Screed On 150mm Thick Reinforced BRC Oversite Concrete Slab on 2 Layers of Damp Proof Membrane 450mm Well Compacted Hardcore/ Laterite Back Fill
B1
GSPublisherVersion 0.1.100.100
Building Section
1:125
450X230X230mm Hollow Sandcrete Block Foundation Wall Filled Solid with Weak Concrete
FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.02.2 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
Y11
Y12
Y13
1,700
+11,400 3 ROOF
DRAWING NOTES
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
2,100
W3
1,700
W3
1,000
W3
2,100
300
+10,500
150 350 100
800 100
150 350 100 869
1,800
727
100
Y1
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
W4
W1
1,050 W1
W4
450
850 W3
W3
1,050 850
+450
300
W4
W3
W3
W3
W4
W3
W3
W3
Project Status:
+450
+450
FOR CONSTRUCTION +600 0 GROUND FLOOR
50
+450
Date
+4,200 1 FIRST FLOOR
2,100
W3
900
W4
Change Name
750
600 300
W3
1,500
W3
450
W3
2,100
W4
ChID
W1
450
1,495
+3,300
Revision History RevID
W4
+4,350 +3,750
+7,800 2 SECOND FLOOR
2,100
W1
2,100
W4
2,450
1,505
150
450
+7,650
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
-900 -1 FOUNDATION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
S
GSPublisherVersion 0.1.100.100
SOUTH ELEVATION1:125
Layout ID A.03.1 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
X1
X2
X3
X4
X5
X6
X7
X8 X9
X10
X11
X12 X13
X14 X15
X16 X17
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
X18
100
100 150 350
+11,100
D1
+11,400 3 ROOF
W3
1,000
+7,800
150
150
+7,800
DRAWING NOTES
+10,500
2,850
W4
+11,400
1,700
3,600
+10,650
150 350 100
1,700
1,400
299
1,358
100
143
+12,900
+7,800 2 SECOND FLOOR
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
ChID
Change Name
Date
600
850
D1
+3,750
+4,200 1 FIRST FLOOR
3,150
150 3,450
1,000
150 3,600
1,000
D1
+4,200
RevID
2,450
2,450
2,450
Revision History
Project Status:
FOR CONSTRUCTION 600
450 150
450
+450
±0
+600 0 GROUND FLOOR
-900 -1 FOUNDATION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
W
GSPublisherVersion 0.1.100.100
WEST ELEVATION 1:125
Layout ID A.03.2 SCALE: 1:125
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
Y12
Y11
Y9
Y10
Y8
Y7
Y6
Y5
Y4
Y3
Y2
Y1
+11,339
+11,400 3 ROOF
DRAWING NOTES
+10,200
300
150
800 100
689
239
274
1,399
1,286
Y13
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
D1
W2
W2
D2
D1
W2
D2
W1
300
300
1,050 150
150
2,100
2,100
Revision History W4
W1
W4
W2
W2
D2
D1
W2
RevID
+4,500 +4,200
NORTH ELEVATION1:125
Change Name
Date
+4,200 1 FIRST FLOOR
+3,000
Project Status: ±0
FOR CONSTRUCTION
+600 0 GROUND FLOOR
-900 -1 FOUNDATION
N
ChID
+900 450 450
+450
+7,800 2 SECOND FLOOR
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
+6,600
1,000
D1
+8,100 +7,800
2,450
W1
W2
W4
1,050 150
W4
W1
2,100
D2
W1
W4
3,000
W2
W4
W1
2,100
W1
W4
300
W1
1,050 150
W4
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.03.3 SCALE: 1:125
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
X18
X17 X16
X15 X14
X13 X12
X11
X10
X9 X8
X7
X6
X5
X4
X3
X2
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
X1
100mm CONC. COPING 100 100 150 350 746
+10,650
W3
150
975 150
DRAWING NOTES
4,139
1,725
+11,400 3 ROOF
+11,100
2,850
D2
2,850
961
343 611
100 300 150 350 345 1,055 100
150 350 100
1,700
100
+12,900
+7,800 2 SECOND FLOOR
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
FOR CONSTRUCTION
150 4,050
+600 0 GROUND FLOOR 450
150
Date
Project Status:
LEAD INNOVATIVE ARCHITECTURE
150
450
EAST ELEVATION 1:125
Change Name
+4,200 1 FIRST FLOOR
-900 -1 FOUNDATION
E
ChID
3,450
3,600 3,600
2,850
900 150
3,300
RevID
150
2,850
450
600
3,300
Revision History
5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.03.4 SCALE: 1:125
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
DOORS SCHEDULE CODE
D1
D2
D3
900
900
750
PLAN
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
900
QUANTITY
900
14
50
2,400
ELEVATION
2,400
2,400
DRAWING NOTES
750
8
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
W x H SIZES
DESCRIPTION
900×2,400
900×2,400
APPROVED ARCHITRAVED PATTERN WOODEN FLUSH PURPOSE MADE DOORS IN STEEL SECURITY WOODEN FRAMES DOORS
ChID
Change Name
Date
750×2,400
PVC DOORS Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE
LOCATION
LIVING ROOMS AND EXITS
BEDROOMS
WC'S
5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT
IES-03DOOR SCHEDULE
1:1
FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.04.1 SCALE: 1:1
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
WINDOWS SCHEDULE
CODE PLAN
W1
W2 1,200
3,000
W3 600
W4 450
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
3,000
1,200
12
8
600
36
1,500
2,100
2,100
ELEVATION
QUANTITY
2,100
DRAWING NOTES
450
20
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
W x H SIZES
3,000×2,100
1,200×2,100
600×2,100
450×1,500
SILL HEIGHT
300
300
300
900
DESCRIPTION
LOCATION
1.4mm THICK BLACK COLORED ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM CASEMENT CASEMENT CASEMENT CASEMENT WINDOW, WITH WINDOW, WITH WINDOW, WITH WINDOW, WITH DOUBLE 5MM DOUBLE 5MM DOUBLE 5MM DOUBLE 5MM THICK (TINTED) THICK (TINTED) THICK (TINTED) THICK (TINTED) TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS TEMPERED GLASS
BEDROOMS
KITCHEN, BQ
IES-04 WINDOW SCHEDULE 1:1
GSPublisherVersion 0.1.100.100
LIVING ROOMS, MASTER BEDROOM, STAIRCASE, BEDROOMS
ChID
Change Name
Date
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT
BATHROOMS
FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.04.2 SCALE: 1:1
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
100mm R.C Coppinp on Party Walls 350
350
348
350
350
18mm Thick Stepped Tile Aluminium Ridge Cap
350 294
75mmX50mm Termite Treated Hardwood Timber Purlins @ 350mm C/C
838
DETAIL 1
350
613
150mm X75mm Termite Treated Hardwood Timber Rafters @1200mm C/C
1,409
100
150
SCALE 1: 20
1,200
1,470
280 282
150mmX100mm Termite Treated Hardwood King Posts @1200mm C/C
300 150
150mmX75mm Termite Treated Hardwood Tie Beam @ 1200mm C/C
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
SCALE 1: 20
DRAWING NOTES
150mm Thick R.C Slab 100mmX75mmX4mm Steel Posts @ 282mm C/C
D-01
Detail
1:50
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
ChID
Change Name
Date
Powder Coated Aluminium Casement Window 25mmX600mm Granite Kitchen Work 400mmX400mX8mm Unglazed porcelain Tiles on
150 300
900
50mm Sand cement Mortar on
FOR CONSTRUCTION
450
150
150
150 150
Project Status:
Damp Proof Membrane
LEAD INNOVATIVE ARCHITECTURE
450mmX230mm Foundation Block Wall to be Filled Solid with Weak Conc.
Project:
5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
D-02
DETAIL 2 SCALE 1: 20 GSPublisherVersion 0.1.100.100
Detail
1:50
Layout ID A.04.3 SCALE: 1:50
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
2,790
3,020
2,529 1,200
430
160
430
1,200
890 160
321
547 230 230
1,200
470
890
303
230
1,200
470
890
303
3,093
5,175
1,860
DRAWING NOTES
20no. 251mm R.C Tread
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
3,093
D-07 STAIRS FIRST FLOOR 1:75 1000mm high, 50mm dia. Stainless Steel Handrail 6mm Thick Clear Glass Baluster Fixed to Manufacturer's Details
2,400
2,400
D-04 STAIRS GROUND FLOOR 1:75
1,200
UP
494
1,200
303
1,182
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
134
8 7 6
406 1,670 1,200
1,455
482
9
21no. 180mm R.C Riser
1,200
10
688
348 230
1,200
412
424
413
348
462
450mmX230mm Hollow Sandcrete Block Wall
230
118 107 251 251 251 251 251 247
11
4 3 2 1
1,200
758
UP
1,200
12
5
230
230
383
230
13
4 3 2 1
95
406
5
112 95
14
20R x 180 19G x 251
8 7
395 251 251 251 251 251 251 251
20R x 180 19G x 251
9
5,370
10
20no. 251mm R.C Tread
2,116
11
5,093
12
1,860
359 251 251 251 251 251 247 255
13
6 161
1,455
1,200
1,200 395 251 251 251 251 251 251 251
2,116
4,516
20 19
DOWN
5,076
15
21no. 180mm R.C Riser
20 19
14
1 17 8 16
1 17 8 16
15
450mmX230mm Hollow Sandcrete Block Wall
DOWN
1,200
426
230 200
230
1,200
261 230
230
330
2,560
230
230 100
230
1,200
430
160
1,200
1,200
230
230
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
Revision History RevID
ChID
Change Name
Date
1,000
25mm Thick Marble Floor Tiles 251mm R.C Tread
180
180mm R.C Riser
510 180
150
+7,440
35mm Nosing
Project Status:
1,200
426
FOR CONSTRUCTION
3,450
450mmX230mm Hollow Sandcrete Block Wall
LEAD INNOVATIVE ARCHITECTURE 1,000 20no. 251mm R.C Tread
+4,200
150mmX1200mmX8mm Porcelain Tiles
+4,200
FOR
1,559 230 360
485
413
160
1,200
303
102
1,200
303
3,450
D-09 STAIRS SECOND FLOOR 1:75
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
15 3
371 295
RC 1483607
PROPOSED RESIDENTIAL DEVELOPMENT
+3,840
Approved Balustrade accesories fixed to Manufacturer's Details
1,571
494
600
5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
Project:
+4,200 +4,020
150
5,317
1,756
21no. 180mm R.C Riser
134
406
1,756 1,559
5,175
230
230 264
230 305
3,093
GSPublisherVersion 0.1.100.100
+7,800
2,450
430
323 197
430
509
547
441
114 111 251 251 251 251 251 247 255 227
88
430
1,200
197
1,200
230
1,200
395 251 251 251 251 251 251 251
160
430
1,200
1,200
230
150
+7,800
180
2,987
60mm dia. Newel Post Fixed to Manufacturer's Details
+780 +600
D-10 STAIRS SECTION
+600
1:75
Layout ID A.04.4 SCALE: 1:75
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES
INSPECTION CHAMBER.
1525mm
1830mm
10.2 m 3
2745mm
2135mm
1830mm
9.63 m
2135mm
3660mm
51.0 m 3
3660mm
915mm
1830mm
2285mm
9.92 m
2285mm
840mm 15,727 1525mm
1905mm
12.75m 3
3,300
11,638
150x150mm concrete quality B 50x75mm rebate for covers.
120mm round channel
outlet.
1220
D
10,304
Sludge
760
230
Gate 2555
450
3,460 SECTION(SOAKAWAY PIT).
1537
75
192
15
00
D
150x150mm r. conc. beam
11,630
50
910
230
3920
610
DRAWING NOTES
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
hollow Blocks built on edge.
Revision History
450
RevID
Change Name
Date
Take-off point
Project Status:
FOR CONSTRUCTION
450
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
150
760
ChID
1538
14,630
2500
150
broken blocks and stone fillingsat bottom.
46,074
1,500
760 B 610
14,995
29,300
Gate 3,000
230
150
150
50mm thick hexagonal concrete interlocked tiles on consolidated literite earth filling on drive way.
1,730
230
150
620
150
entry
9,600
edge of 75mm thick concrete cover
150
18,455
230
16,774
150x150mm r. conc. beam
broken blocks and stone fillings etc.
5,905
3,300
PLAN. (INSPECTION CHAMBER).
2850 75mm precast concrete covers quality A reinforced with 914 mesh spm.
24,360
PROPOSED POULTRY ROOM
PROPOSED BUILDING entry
150mm thick concrete slab Quality B floor STAFF finish laid to BUILDING fall at 1:20. 6,345
7,158
300
3000
2,000
4,152
5,822
LONGITUDINAL 13,668 SECTION(SEPTIC TANK).
265
200mm Soil pipe Gradient 1:40
PROPOSED
PROPOSED FISH POND
500
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
SOAKAWAY PIT. 150
9,330
50x212mm m.s. strap built into block painted with bitumen.
230
12,182
1400
Car-park
50mm precast concrete baffle wall.
200mm dia. soil pipe to soakaway pipe laid to 1;40 gradient.
10,830
17,721
230mm block work filled with 1:10 concrete with 12mm rendering internally.
300
29,300
soil graded asbestos inlet pipe. 150mm concrete quality A
1830mm
6,030
150
150
900
Gate
1830mm
150mm Thick Rienforced Concrete Slab
step iron as required in manholes soil graded asbestos at 300mm ctrs 18mm dia. m.s. rods outlet pipe 600mm long U shaped bent and built into 150mm blockwork. 3,300 level of effluent.
short lengh of pipe
inlet.
3
SECTION. (INSPECTION CHAMBER).
450
6,517
GL.
1220mm
45,027
75mm precast concrete covers quality A reinforced with 914 mesh spm. 4,940
15,952
1220mm
100mm dia soil graded asbestos outlet pipe
3
SEPTIC TANK. 150x150mm concrete quality B 50x75mm rebate for covers.
2
450
1830mm
1220mm
910mm
450
3
760mm
910mm
ACCESS ROAD
610mm
B
1
150
m3
1675mm
500
3.55
2745mm
150
20
3
15,060
m3
7.65 m
gutter
5.30
1905mm
7,460
150
1220mm
A
gutter
m
3 5410mm
610mm
DIMENSIONS TYPE
1,070
3050mm
14.15
55 1220mm 15,5
gutter
utilization factor
200
20
1830mm
2285mm
6,230
m3
610mm
5.10 m 3
7,460
2.55
1915mm
1220mm
3,800
2745mm
m
40
3
2285mm
2,730
2860mm
2.15
4440mm
3.54 m 3
gutter
2590mm
1.70
30
2285mm
1830mm
7,460
m
3
20
1370mm
5,140
1220mm
2,460
510mm
9,749
2360mm
150 450x450mm conc. cover.
17,479
1370mm
3
500
SCHEDULE (SOAKAWAY PIT).
7,730
450mm
m
150
B
1800
2030mm
1.50
A
3 2.55 m
3,437
10 15
D
DIMENSIONS
5,000
C
1.15 m 3
Volume Of Filtering Material And Soak Away Pit.
3,448
A
DIMENSIONS B
1,867
CAPACITY
1,057
NO. OF USERS
(SEPTIC TANK SIZES).
400
SCHEDULE
DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
ACCESS ROAD
PLAN.(SEPTIC TANK).
3150
PLAN.(SOAKAWAY PIT).
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
JOB NO: JOB NO:
DATE: DATE:
JOB TITLE: CLIENT: JOB TITLE: CLIENT: MOHAMMAD ALKASIM PROPOSED FARM HOUSE ATAT PROPOSED FARM HOUSE MUHAMMED GARBA MrAHMAD AND Mrs Adebowale MUHAMMED GARBA PROPOSED RESIDENTIAL GWAZAYE BYBY TRAPCO, GWAZAYE TRAPCO, AIRPORT ROAD, KADUNA STATE DEVELOPMENT AIRPORT ROAD, KADUNA STATE DRAWING TITLE: DRAWING TITLE:
2015 AAW/013 AUGUST, 2014 14 JANUARY/ March AAW/013 AUGUST, 2014 S/NO. REVISION S/NO. REVISION
DATE DATE
SITE PLAN SOAKAWAY PIT
GSPublisherVersion 0.0.100.100
SOAK AWAY DETAIL 1 1:1.25
GSPublisherEngine 0.10.100.100 0.3.100.100 GSPublisherEngine GSPublisherEngine 0.0.100.100 GSPublisherEngine 0.3.100.100
GSPublisherVersion 0.1.100.100
CONSULTANTS: CONSULTANTS:
Osheidu
SCALE: SCALE:
TRIAD TRIADASSOCIATES ASSOCIATES ARCHITECTS+CONSULTANTS ARCHITECTS+CONSULTANTS 2929 RABAH ROAD, MALALI-KADUNA RABAH ROAD, MALALI-KADUNA 08034668222 08034668222
NOT TO SCALE DRAWN BY: DRAWN BY:
A.A.WAKIL A.A.WAKIL
DESIGNED BY: DESIGNED BY:
A.A.WAKIL A.A.WAKIL
APPROVED BY: APPROVED BY:
SHEET N0: SHEET N0:
A-19
001 AA-001 A07
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.04.5 SCALE: 1:1.25
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
ChID
Change Name
Date
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.04.6 SCALE: 1:1.05
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020
GENERAL NOTES DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE INDICATED All relevant details, levels, dimensions, setting out positions are to be checked prior to any work commencing and any discrepancies are to be brought to the attention of the Architect. The Architect accepts no responsibility for errors resulting from misinterpretation of the drawings. All dimensions are given in millimeters unless otherwise noted. Drawings are to read in conjunction with Engineer's drawings. Contractor to keep full set of drawings on site. Contractor is responsible for the correct setting out of the building on site with particular reference to boundaries and building lines. Contractor and Engineer to verify all levels and dimensions on site and check same against Architect's drawings before commencing work. Figured dimensions to be used as preference to scaled dimensions. Large scale details to be used where available.
COPYRIGHT: The copyright of the literary works, artistic works and published editions contained herein is vested with LEAD INNOVATIVE ARCHITECTURE Any adaption, distribution, sale or for hire, or any form of reproduction of these works, in any part or in their entirety, by any party other than LEAD INNOVATIVE ARCHITECTURE is an infringement of this copyright, and LEAD INNOVATIVE ARCHITECTURE reserves the right to claim damages from any party infringing this copyright, unless these rights are varied in writing.
DRAWING NOTES
CLIENT ENDORSEMENT : It is agreed that the client, by its signature to this drawing, accepts and approves the conceptual design and / or technical informations contained herein. CLIENT / CLIENT REPRESENTATIVE : DATE :
Revision History RevID
ChID
Change Name
Date
Project Status:
FOR CONSTRUCTION
LEAD INNOVATIVE ARCHITECTURE 5D KANTA ROAD, KADUNA, NIGERIA T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8 E M A I L : leadinnovativearchitecture@ gmail.c o m
RC 1483607
Project: PROPOSED RESIDENTIAL DEVELOPMENT FOR
DAN YARO AUDU (NIG) LTD
LOCATION; NO. 537, WUYE DISTRICT CADASTRAL ZONE B3 ABUJA
Layout ID A.04.7 SCALE: 1:1.05
GSPublisherVersion 0.1.100.100
Designed by A. T Arc. Checked by Arc. S. A
Revision 02 DATE AUGUST,2020