CardioMem Getemed

Page 1

Photo: Udo Gnoß

CardioMem

®

Multi-channel digital recorders CardioMem® CM 4000 for Holter ECG

Cardiac function diagnostics Vital signs monitoring Telemonitoring


CardioMem® CM 4000

Digital Recorders for Holter ECGs Simple, fast, and reliable – that’s what our customers look for when it comes to recording and analysing Holter ECGs. The extremely lightweight, easy to use, CardioMem® CM 4000 recorder supports the user throughout all phases of recording Holter ECGs, from applying the electrodes and entering patient demographic data up to inspecting the ECG waveforms. Innovative Technology – Comprehensive Functionality Helpful functions, such as the detection of faulty electrode contacts or continuous battery monitoring, reduce the risk of corrupted or shortened recordings and hence the costs and troubles associated with having to repeat examinations. Optional auxiliary information that can aid in the final diagnosis, such as transthoracic impedance variations (which show respiration activity during sleep), pacemaker function and/or an activity profile, can be acquired simultaneously to the ECG without any additional electrodes.

Excellent Design and Ease of Use A large color display with touch screen offers an overview of all the necessary information, including patient demographic data, a diagram of the thorax showing correct electrode hook-up in accordance with the patient cable attached, an electrode impedance gauge, ECG waveforms and battery status. Using the touch screen, the user is intuitively guided through the recorder menus and can make changes to the configuration if necessary. The CardioMem® CM 4000 is small, lightweight and ingress protected against splashed water and dust, making it ideal for everyday use. 4, 5 or 7 lead patient cables are available for different types of recordings. All patient cables are defibrillator safe. Depending on the recording requirements, casings for AA or AAA batteries are available. For even longer recordings, the battery can be replaced and the recording continued.

The CM 4000 series Option Operating time with one alkaline battery ECG cables: 2 channel (5 lead), 3 channel (4 or 7 lead) High-resolution storage (1024 Hz / 12 bit) Activity sensor Pacemaker pulse detection Acquisition of transthoracic impedance Voice recorder Bluetooth® interface

CM 4000

CM 4000 B

2 days

5 days


user-friendly modular reliable Doctor

CardioMem®

Patient Status information

Status information

Recording length of up to 5 days with a single battery

Bluetooth®

Computer

Hi-Speed USB

Manual patient data entry Voice recording Device test

ECG Activity sensor Pacemaker detection Transthoracic impedance variations

4, 5 or 7 lead cables Data evaluation with CardioDay® analysis software

Patient data entry ECG data read out

Online ECG

Bluetooth® Interface An optional integrated Bluetooth® module allows for encrypted, bi-directional data transfer with a PC. This technology can be used to transfer patient demographic data, configure recorder settings, e.g. length of recording, as well as synchronise the internal recorder clock with the PC clock before the recording begins. Furthermore, the ECG and optional auxiliary waveforms can be wirelessly transmitted online during the recording. Using CardioDay®, our analysis software tool, the information can be displayed, measured, printed and exported, for example, as an XML file. This feature makes the CardioMem® recorders ideal for collecting safety ECGs during pharmaceutical studies. When Time is of the Essence – the Voice Recorder The user can decide whether, prior to use, a patient ID or demographic data be transferred from a PC to the recorder, or if it is to be manually entered using the recorder interface. If the user is pressed for time, he or she can choose to dictate the patient information directly to the device via the voice recorder. The person carrying out the analysis then has an additional media file with information at his or her disposal, thus reducing the risk of a mix-up in data during the subsequent analysis phase.

Automatic cable type recognition Automatic display adaption

Hi-Speed Data Transfer At the end of the recording period, the acquired data are transferred to a PC via the Hi-Speed USB interface. After downloading, the recorder is immediately ready for the next patient.

Highlights Brilliant color display Touch screen graphical user interface (GUI) Self-orientating GUI for left- or right-handed users Activity sensor Flat housing, protected against splashed water Automatic recognition of patient cable type Defibrillator safe cables Voice recorder for patient identification Bluetooth® interface for online ECG, data exchange Hi-Speed USB interface Perfect for pharmaceutical studies