MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 1
GE Healthcare
Fundamental fit MAC 3500 resting ECG analysis system
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 2
Built on a strong
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 3
foundation. The MAC family of resting ECG systems has been known to be one of the hardest-working in the industry. With a trusted reputation for innovation. And a track record for performance. The MAC 3500 upholds that name—and everything it implies.
GE and its affiliated companies have a strong history of innovation when it comes to ECG. How else would you describe over 40 years of research and development? Ongoing collaboration with leading consulting cardiologists and physicians. To produce a fundamentally sound program that supports confident ECG analysis and interpretation – our advanced Marquette* 12SL*.
As a matter of fact, hard at work is the perfect way to describe this addition to GE’s MAC* family of resting ECG analysis systems. Ideal for basic 12-lead resting ECG analysis, the MAC 3500 system delivers technology you need to support reliable and accurate cardiac assessments. With a common interface and intuitive operation that sets the groundwork for increased productivity and efficiency. All contained in an affordable and reliable electrocardiograph unit. So that your work is easier.
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 4
Right tool –
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 5
– right choice. With the MAC 3500, you get the strength of our Marquette ECG analysis programs. It’s the same technology that’s found throughout our family of ECG analysis systems, providing you with consistent measurement and interpretation. These programs continue to be a preferred choice of hospitals, clinics, physician offices and clinical research organizations for their uncompromising quality and reliability: • Marquette 12SL ECG simultaneous 12-lead ECG analysis program for adults and pediatrics – one of the industry’s most clinically validated programs. • Marquette Hookup Advisor* signal quality analysis program reviews and measures ECG waveforms for signs of artifact and interference, helping to avoid poor waveform quality during the recording of ECGs. • Marquette 12SL with Gender-Specific Interpretation makes detecting acute myocardial infarction (MI) easier in women.
• Acute Coronary Syndrome (ACS) Algorithm implemented in the MAC 3500 has been shown to improve the sensitivity of emergency physicians’ interpretation of acute myocardial infarction by 50% and cardiologists’ interpretations by 26%, with no loss of specificity.1 The new ACS algorithm also improved the emergency physician’s acute ischemic syndrome interpretation sensitivity by 53%, while maintaining a specificity of 91%1. • Configurable critical values can speed triage and time to treatment for patients at high risk of cardiac events with onscreen and printed notifications. Additionally, the feature can help support your facility’s patient safety goals and the Joint Commission’s reporting requirements through consistent reporting of critical conditions.
1. Xue J, Aufderheide T, Scott Wright R, Klein J, Farrell R, Rowlandson I, Young B. Added value of new acute coronary syndrome computer algorighm for interpretation of prehospital electrocardiograms. J Electrocardiol 2004; 37 Suppl:233-239. “co-authored in part by GE Healthcare employees”
Extensive customization of display and final-report formatting accommodates user preferences. Security protocols and userconfigurable password protection help to address HIPAA requirements.
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 6
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 7
From training to connectivity and service, GE Healthcare has the resources, technology and commitment to support you all the way.
The rest is easy. Need to train your entire staff? Sure. Thinking of expanding to ECG management? No problem. With GE, you can relax. The next steps are all taken care of. • Optional communications package allows you to tap into the power of GE’s MUSE* cardiology information system, for streamlined workflow and higher functionality. • Barcode reader option enables orders or ADT demographic data download to help reduce patient data entry time and errors by automating the process. • CEU credits support your professional career. (U.S. only)
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 8
MAC 3500 Resting ECG System Instrument type:
Communications
Microprocessor augmented automatic electrocardiograph; 10-leadwire acquisition with programmable lead configuration; 12-leadwire acquisition with NEHB configuration.
MUSE Cardiology Information System compatible EMR connectivity via MUSE Cardiology Information System or CardioSoft
Processing ECG Interpretation: Computerized measurements:
ECG analysis frequency:
CardioSoft* compatible
Marquette 12SL ECG Analysis Program for Adults and Pediatrics
Optional:
Serial cable Internal or external modem/fax
12-lead analysis includes measurements of user-selectable additional 3 NEHB leads
Fax Class 2, Group 3 MobileLink Wireless (requires additional MUSE communications software and installation):
500 samples/second/channel
ECG storage:
50 ECGs in internal memory
External archiving:
Secure digital card (up to 2 GB)
Digital sampling rate:
16,000 samples/second/channel
Pre-acquisition:
Provides 10 seconds of instantaneous ECG acquisition
– Enhanced Security WPA and WPA2 (personal and enterprise modes), PAP, MS-CHAPv2, 802.1x EAP with TLS/TTLS/LEAP/PEAP/ FAST, WEP (PEAP requires network evaluation/approval prior to purchase
Dynamic range:
AC Differential ± 5mV, DC offset ±300 mV
– Ultra-High Security MobileLink (FIPS 140-2)
Resolution:
4.88 μV/LSB @ 250 sps, 4.88 μV/LSB @ 500 sps
Frequency response:
–3 dB @ 0.01 to 150 Hz
LAN (requires additional MUSE communications software and installation)
Common mode rejection:
>140 dB (123 dB with AC filter disabled)
Input impedance:
>10MΩ @ 10 Hz, defibrillator protected
Patient leakage:
<10 μA
Pace detect:
– Communication with MUSE over LAN thru internal RJ-45 jack
Display Display type:
6.5 in (165 mm) diagonal graphics backlit AM LCD (color optional)
Meets or exceeds ANSI/AAMI EC11-1991 standards
Display resolution:
640 x 480 pixels with waveform enhancement
Special acquisition functions:
Disconnected lead detection, electrode impedance, excessive AC noise, baseline wander and muscle tremor messages
Display data:
Heart rate meter:
30 to 300 BPM ±10% or 5 BPM, whichever is greater. Heart rates outside this range will not be displayed.
Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, and help messages. 6 leads maximum.
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
Writer
23.9.2011
08:46
Page 9
Physical specifications 5, 12.5, 25, & 50 mm/s
Height: Height: Width:
7.6 in (19.3 cm)†7.6 in (19.3 cm)* Approximately 15.6 in (39.6 cm)†
Number of traces:
3, 6, or 12 user selectable
Depth:
15.0 in (38.1 cm)†
Writer sensitivity/gain:
2.5, 5, 10, 20, 10/5 (split calibration) mm/mV
Weight:
Approximately 7.0 kg (15.5 lbs)† including battery without paper
Writer speed accuracy:
±2%
Writer amplitude accuracy:
±5%
Writer resolution:
Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical
Environmental specifications
Paper type:
Thermal, Z-fold, perforated, fan fold, 300 sheets/pack
Temperature:
Paper size:
A Size: 8.5 in x 11 in, (214.6 mm x 280 mm)
Writer technology:
Thermal dot array
Writer speeds:
Approximately 7.6 kg (16.8 lbs)† including KISS pump and battery without paper
A4 Size: 8.27 in x 11.7 in (210 mm x 297.5 mm)Keyboard
Sealed elastomer with soft function keys, alphanumeric keys, writer controls, and TrimPad cursor controls
Electrical AC or battery operation
Voltage:
100 to 240 VAC
Current:
0.5A @ 115 VAC, 0.3A @ 240 VAC, typical, 0.85A max
Frequency:
50 to 60 Hz
Battery type:
User replaceable, 18V @ 3.5 AH ±10% rechargeable NiMH
Battery capacity:
100 single page reports, (typical) or 6 hours continuous display (without printing)
Battery charge time:
Approximately 4.5 hours from total discharge (with display off)
–40°to 158° F (–40° to 70° C)
Operating:
20% to 95% RH non-condensing
Transport/storage:
15% to 95% RH non-condensing
Pressure:
†
Power supply:
50°to 104° F (10° to 40° C)
Transport/storage: Humidity:
Keyboard Type:
Operating:
Operating:
700 to 1060 hPA
Transport/storage:
500 to 1060 hPA
without trolley
Barcode Scanner specifications Symbologies
Code 39 (extended), PDF-417, Code 128, Data Matrix, Interleaved 2 of 5.
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 10
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 11
Certification UL classification, CSA classification.
Warranty Standard warranty is one year.
Ordering information Visit gehealthcare.com or contact your local GE Healthcare representative. Accessories available from www.gehealthcare.com
MAC3500 brochure_DOC0907570_eng.qxd:MAC3500 brochure_DOC0907570_eng
23.9.2011
08:46
Page 12
©2011 General Electric Company – All rights reserved. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. * GE, GE Monogram, 12SL, CardioSoft, Hookup Advisor, MAC, Marquette, MobileLink, and MUSE are trademarks of General Electric Company.GE Healthcare, a division of General Electric Company. GE Healthcare, a division of General Electric Company.
Healthcare Re-imagined GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, biopharmaceutical manufacturing technologies, performance improvement and performance solutions services helps our customers to deliver better care to more people around the world at a lower cost. In addition, we partner with healthcare leaders, striving to leverage the global policy change necessary to implement a successful shift to sustainable healthcare systems. Our “healthymagination” vision for the future invites the world to join us on our journey as we continuously develop innovations focused on reducing costs, increasing access, and improving quality around the world. Headquartered in the United Kingdom, GE Healthcare is a unit of General Electric Company (NYSE: GE). Worldwide, GE Healthcare employees are committed to serving healthcare professionals and their patients in more than 100 countries. For more information about GE Healthcare, visit our website at www.gehealthcare.com
GE Healthcare P.O. Box 900, FIN-00031 GE, Finland Tel. +358 10 394 11 Fax +358 9 146 3310 www.gehealthcare.com
DOC0907570, Rev: 2