/ACO%20Eurocover

Page 1

CI/SfB|

|(52.5)|

September 2005 Uniclass L7315

ACO EuroCover Stainless steel composite double sealed access covers

|


ACO Building Drainage

ACO Building Drainage Our built environment is becoming ever more complex. Applications are becoming more sophisticated and the increasing pressure of regulations and standards make achieving design, performance and financial goals ever tougher. ACO Building Drainage is a new concept within the ACO Group. Our mission: to eliminate design risk, to reduce installed and life cost and to deliver exceptional finish and performance in every product application.

ACO Building Drainage’s extensive portfolio includes:

Stainless steel Modular Channel system

Stainless steel EuroGully gully system

Stainless steel and polymer composite access covers

Biological Grease Management system

Gravity Grease Separator system

Sewer backflow prevention valves

Stainless steel socketed pipe system

We achieve this through three factors:

Rainwater outlets for flat roofs

High performance materials

Design experience and project support

Global manufacturing capacity

For further information on these products and services please consult our comprehensive range of specification and installation guides.

Applied to a range of products for use within, or near to the building envelope, our solutions offer best value where high performance is prerequisite.

ACO Building Drainage is a division of ACO Technologies plc and part of the worldwide ACO Group.

Delivering through understanding, innovation and support

The Group has sales in excess of £300 million worldwide with production facilities in the UK, Germany, France, Switzerland, Denmark, Spain, Poland, Czech Republic, Australia and the USA. In total more than 3000 people are employed in 30 countries throughout the world.

Whatever the material - stainless steel, cast iron, aluminium alloy, polyethylene and polypropylene – our global resources and fabrication capacity make it possible for us to deliver best value both with our standard products and with our bespoke designs. Confidence is further assured with quality systems that are in accordance with ISO 9001.

Contact Details ACO Technologies plc ACO Business Park, Hitchin Road, Shefford, Bedfordshire SG17 5TE.

Tel:

01462 816666 Fax:

01462 851490 e-mail Enquiries:

buildingdrainage@aco.co.uk website:

www.acobuildingdrainage.com


ACO EuroCover CONTENTS

System Overview

Introduction to ACO EuroCover

3

Features and benefits

4

Load Class selection

4

Technical Data

ACO EuroCover

5

ACO Building Drainage Vinyl Seal

5

Installation

Installation procedure ACO EuroCover

6

Installation procedure ACO Building Drainage Vinyl Seal速

7

Operation and Maintenance

General maintenance

7

Specification Clause

NBS Specification Clause Information

Introduction to ACO EuroCover Traditional fabricated access covers can pose significant installation and service issues that can adversely affect the reliability and serviceability of the product. A traditional cover in practice is difficult to install correctly, resulting in a nonair and water tight installation.

7 Typical applications include:

Kitchens

Food and drink processing plants

Abattoirs

Hospitals

Chemical and pharmaceutical plants

Commercial premises

Leisure centres

ACO EuroCover combines austenitic stainless steel and polyester resin concrete to produce a rigid, reliable, air and watertight installation. Available in a wide range of sizes and suited to medium or heavy duty applications, ACO EuroCover accommodates a wide range of floor finishes. When used with ACO Building Drainage Vinyl Seal速 vinyl sheet flooring can be fitted easily without the need for cumbersome clamping mechanisms, reducing potential bug traps significantly.

3


ACO EuroCover SYSTEM OVERVIEW

Features and benefits

1

1

Removable ‘grit seal’ facilitates cover removal even after long periods of trafficking

2

Four point lockdown and lifting key mechanism for safe and convenient access

3

Cover supplied without infill, allowing match to surrounding floor finish

2

3

4

Corrosion resistant grade 304 austenitic stainless steel cover and frame

5

Purpose made covers available in grade 316 for chemically aggressive environments.

6

6

Six standard size options available

7

7

FACTA Load Class AAA and E to suit most applications

8

Integral polymer concrete support frame provides economical structural rigidity

9

‘4 lip’ creep resistant EPDM double seal ensures air and watertight operation

4 5

8 9

10 Compatible with a wide range of floor finishes including epoxy, polyurethane and concrete screeds, ceramic tile and vinyl sheet flooring

10 11

11 Anchor tangs ensure a positive key to the surrounding haunch 12 Optional ACO Building Drainage Vinyl Seal® provides robust and safe interface with vinyl floors and can be fitted to both external frame and internal cover area

12

Load Class Selection Wide range of sizes available for medium and heavy duty applications as follows: Slow Moving

Slow Moving Solid

Pneumatic Wheel Load

Wheel Load

FACTA Load Class

(Tonnes)

(Tonnes)

AAA

2.5

0.5

Typical Applications Light industrial areas, trolleys and light pallet trucks.

E

16.0

5.0

Heavy duty industrial areas, heavy duty fork lift trucks and HGV’s.

4


ACO EuroCover TECHNICAL DETAIL

ACO EuroCover Standard All ACO EuroCovers supplied with lifting keys and grit seal

C

D

AxB

Part No.

A

B

C

D

FACTA Load Class

Weight (kg)

300mm x 300mm clear opening

49556

492mm

492mm

85mm

50mm

AAA

27.5

450mm x 450mm clear opening

49550

642mm

642mm

85mm

50mm

AAA

38.0

600mm x 450mm clear opening

49551

792mm

642mm

85mm

50mm

AAA

44.0

600mm x 600mm clear opening

49552

792mm

792mm

85mm

50mm

AAA

50.5

750mm x 600mm clear opening

49560

942mm

792mm

85mm

50mm

AAA

58.0

750mm x 750mm clear opening

49558

942mm

942mm

85mm

50mm

AAA

61.5

300mm x 300mm clear opening

49557

492mm

492mm

145mm

110mm

E

31.0

450mm x 450mm clear opening

49553

642mm

642mm

145mm

110mm

E

43.5

600mm x 450mm clear opening

49554

792mm

642mm

145mm

110mm

E

51.0

600mm x 600mm clear opening

49555

792mm

792mm

145mm

110mm

E

58.0

750mm x 600mm clear opening

49561

942mm

792mm

145mm

110mm

E

65.0

750mm x 750mm clear opening

49559

942mm

942mm

145mm

110mm

E

71.0

Lifting key for ACO EuroCover

49069

-

-

-

-

-

-

Description

ACO Building Drainage Vinyl Seal速 Channel Edge

Flexible seal

Heat welded joint

Vinyl sheet flooring (2-4mm thick) Floor adhesive

Rigid seal extrusion (Patent applied for)

Description

Part No.

300mm x 300mm vinyl seal kit

49562

450mm x 450mm vinyl seal kit

49428

450mm x 600mm vinyl seal kit

49429

600mm x 600mm vinyl seal kit

49430

750mm x 600mm vinyl seal kit

49563

750mm x 750mm vinyl seal kit

49564

5


ACO EuroCover INSTALLATION GUIDELINES

Installation procedure

Step 3 Place the recessed cover on a level and flat surface and fill with a suitable 10mm aggregate concrete infill of minimum compressive strength of 40N/mm2. To accommodate various floor finishes the cover may be filled to within 12mm of the finished floor level.

General Allow sufficient time for mortars and concrete to reach required minimum compressive strength. Step 1 Ensure the supporting structure and / or the ground conditions are adequate to support the expected operating service load.

Step 4 Ensure the double seal gasket is clean and in position. Lift the complete recessed cover into place using supplied lifting keys and appropriate lifting apparatus; depending on size and infill material the complete cover may exceed Health and Safety Regulation lifting recommendations.

The frame assembly must be continuously supported along its entire length and width on a mortar of minimum compressive strength 30N/mm2 to a minimum depth of 10mm. Position the top edge of the rigid frame assembly so that it is level with the finished floor, or at a maximum of 1.5mm below the finished floor.

Lubricate and insert all 4 fixings, locating each positively before tightening. Fasten down the cover until resistance is felt, observing the following sequence: top left hand, bottom right hand, bottom left hand, top right hand. Finally tighten a further one quarter turn.

Step 2 Backfill around the ACO EuroCover, and, if using ACO Building Drainage Vinyl Seal速 with sheet flooring refer to the installation details overleaf.

Step 5

A mastic sealant of bead width 5-8mm is recommended to the edge of the ACO EuroCover to ensure a watertight seal.

Insert supplied grit seal between the recess cover and frame.

ACO EuroCover installation diagram 2

1

2

6

3

4 5

8

6

5

7

1

ACO Building Drainage Vinyl Seal速

5

Mastic sealant

2

Sheet flooring

6

3

Specified floor material, maximum depth 12mm, for example: ceramic tile, epoxy, polyurethane or concrete screeds.

Finished floor level maximum 1.5mm above ACO EuroCover.

7

Bearing width of mortar bed.

8

10mm aggregate concrete infill of minimum compressive strength of 40N/mm2 to within 12mm of finished floor level.

4

Removable grit seal


ACO EuroCover INSTALLATION GUIDELINES

ACO Building Drainage Vinyl Seal速 Step 1 Ensure the assembled rigid and flexible Vinyl Seal速 sits square and horizontal in the ACO EuroCover edge detail. Step 2 Install the ACO EuroCover into the ground ensuring that the flooring screed is flush to the top edge of the rigid PVC extrusion. Protect the ACO EuroCover and seal assembly from splashes of concrete/screed.

Lay the sheet flooring against the flexible seal edge and prepare the welded joint between the flexible seal and vinyl sheet flooring as normal by scoring the sheet / seal joint to approximately half the depth of the sheet flooring thickness. Either in-colour or black welding filler rod may be used to weld the joint. Remove surplus weld material from the joint using a spatula when the welded joint has cooled. Channel Edge

Flexible seal

Heat welded joint

Vinyl sheet flooring (2-4mm thick) Floor adhesive

Step 3 Rigid seal extrusion

Depending upon the installation, additional suitable fixings may be required to secure the rigid extrusion to the floor substrate. If this should be required, separately drill and countersink the rigid extrusion making sure that all fixings are finished flush with the top of the extrusion. Step 4 Grout any voids at connecting rigid PVC joints at mitred corners, straight joints or fixings, to ensure a continuous supported floor finish. Prior to laying the vinyl sheet flooring, peel the protective film from the rigid extrusion (a knife may be required to cut the film adjacent to the flexible seal) and ensure all surfaces are clean and dry. Apply a compatible adhesive also to the top surface of the rigid PVC extrusion, for example, Altrofix 19 two-part water resistant eurethane adhesive, taking care not to apply adhesive to the flexible seal.

(Patent applied for)

Operation and Maintenance For general maintenance and cleaning of stainless steel refer to ACO Building Drainage Eurogully or Modular channel catalogues. To remove the recessed cover remove the push fit grit seal, then undo hexagonal cap screws. Undo gradually observing the sequence in step 4 of installation instructions. Insert lifting key fully into the cover at two or more points. Lift with appropriate apparatus. To replace the cover follow step 4 of installation instructions. NBS Specification Clause Reference For relevant NBS specification, refer to NBS Section P31 holes/chases/covers/support for services, Clause 370 access covers/gratings and insert the appropriate model reference number.

7


ACO Technologies plc ACO Business Park, Hitchin Road, Shefford, Bedfordshire SG17 5TE Tel: 01462 816666 Fax: 01462 851490 e-mail: buildingdrainage@aco.co.uk website: www.acobuildingdrainage.co.uk

Š September 2005 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of continuous product development and improvement renders specifications liable to modification. Information provided in this brochure is therefore subject to change without prior notification.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.