Luminous Ion Inverter/Charger

Page 1

Long Back-up Square Wave Inverter

I ON 500 MAINS ON

ABCC CHG

UPS ON

LOW BATT.

OVER LOAD

SWITCH ON


Luminous presents the latest breakthrough in the world of power back up Inverter. Apart from powerful performance, these long back up Inverters are designed to run your electrical Appliances in harsh conditions. Continuous research and development Inverters more evolved to suit all demands of the customer around the world. ion 300 Features • Higher Efficiency & Long back up. • Ripple free charging (ABCC Technology*) • Low electricity consumption. • Regulated UPS mode –Computer with TFT can also be used. • Battery charging selection switch as per type of battery connected. • Hybrid design. • Plastic body, Small Size & Very Light Weight ion 500 Features • Higher Efficiency & Long back up. • Ripple free charging (ABCC Technology * )

I ON 500 MAINS ON

• Low electricity consumption.

ABCC CHG

UPS ON

LOW BATT.

OVER LOAD

SWITCH ON

• Regulated UPS mode –Computer can also be used. • Battery charging selection switch as per type of battery connected. • Hybrid design. • Small Size & Light Weight

TEST CONDITION

PARAMETER Under voltage Cut off AC INPUT

Under voltage Restoration Mains Over Voltage Cut Off Over Voltage Restoration

MODE OF BATTERY

SPECIFICATIONS iON 300 REGULATED MODE

175 180 260 255

± 10V ± 10V ± 10V ± 10V

110 120 280 270 42 - 60Ah 1 12V

Number Of Battery used Nominal DC Input Voltage Low Voltage cut off @ full load Charging Current Trickle/Float Voltage

PARAMETER Output Voltage @ no load Output Voltage @ full load OUT PUT

Running Load

10.5V+/-0.2V 10.35V+/-0.2V 5A +/- 1.5A 4A +/- 1.5A 13.8 +/- 0.15V REGULATED MODE

Output Voltage & Frequency (Mains Mode)

255V ±15V 200V±15V 240W±25W

SPECIFICATIONS iON 500 REGULATED MODE

UNREGULATED MODE

170 ± 10V 175 ± 10V 260 ± 10V 255 ± 10V

120 ± 10V 280 ± 10V 270 ± 10V

FLAT PLATE BATTERY

TUBULAR BATTERY

110 ± 10V

88 - 120Ah 1 12V 10. 5V+/ -0.2V 10.35 V+/ -0.2V 10A +/ - 1.5A 9A +/ - 1.5A 13.8 +/ - 0.15V REGULATED MODE

UNREGULATED MODE

255V ±15V 210V±15V 440W±40W

255V ±15V 200V±15V 460W±40W

50Hz±2Hz

50Hz±2Hz

Same as input

Same as input

CONDITION

LED DISPLAY

Switch ON

Short Circuit

UPS ON LED YELLOW UPS ON LED YELLOW FAULT LED RED MAINS ON LED GREEN NOT APPLICABLE FAULT LED RED FAULT LED RED BLINKING

Temperature Cut Off

FAULT LED RED

UPS ON LED YELLOW + LOW BATT. LED RED + OVER LOAD LED RED

CONDITION

RANGE

Operating Temperature Relative Humidity

0-45° C (32-113° F) 0-45° C (32-113° F) 0-95 % RH non-condensing

RANGE 0-45° C (32 -113° F) 0-45° C (32 -113° F) 0-95 % RH non -condensing

Audible Noise

< 55 dB

< 55 dB

UPS ON Battery Low Mains On Charging ON Overload

ENVIRONMENT

UNREGULATED MODE

255V ±15V 210V±15V 225W±25W

Output Frequency

INDICATION

± 10V ± 10V ± 10V ± 10V

TUBULAR BATTERY

FLAT PLATE BATTERY

Type of Battery DC INPUT

UNREGULATED MODE

Storage Temperature

LUMINOUS POWER TECHNOLOGIES PVT. LTD. C8 & C9, Community Centre, JanakPuri, New Delhi - 110058. Ph.: 011-40778221/222. Web : www.myluminous.com

LED DISPLAY SWITCH ON LED YELLOW UPS ON LED YELLOW LOW BATT. LED RED MAINS ON LED GREEN MAINS ON LED GREEN + ABCC CHG LED RED OVERLOAD LED RED OVERLOAD LED RED BLINK