Venture Lighting Bright ideas Bold innovations
HID Lighting Systems Catalogue Australia | New Zealand | Asia
 2
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Global Perspective Venture Lighting is the world leader in metal halide lighting technology. Since 1983, Venture Lighting has created a constant stream of new systems for our customers. Our range of optimized lamps and control gear, including the revolutionary Uni-Form速 pulse start system, has grown to encompass lamp wattages from 20 to 2,000 watts. This unique focus offers peak performance lighting. Our North American headquarters includes a state-of-the art development and new products manufacturing centre to support our leadership in originating new systems. Venture Lighting is part of the Advanced Lighting Technologies group of companies.
Our sister companies feature complementary capabilities: APL Engineered Materials (APL) Strategic supplier of halides, amalgams and other components to the lighting industry.
Deposition Sciences, Inc. (DSI) A leader in sophisticated thin film coatings and deposition systems to the lighting industry.
Auer Lighting Leading supplier of lighting omponents such as reflectors, Fresnel lenses, filters and dental reflectors, as well as other pressed components for technical application such as MAXOS速 safety sight glasses. Auer Lighting are specialists in providing expertise for special glass production, optical design and coating.
Venture Lighting is based in Ohio, USA and have offices in Canada, England, India, Australia, New Zealand and Singapore. Quality is sustained through control systems constructed to meet ISO 9001 standards. Along with our premier lamp facility in North America, our Indian facility is the largest metal halide plant in the Pacific Rim, producing both lamps and control gear. Venture Lighting introduced most of the metal halide lamp types currently in use around the world and continue to lead the industry.
An Innovator and Worldwide Manufacturer
Venture Lamps
Contents Venture Lighting Asia Pacific
4
Simply a Better Metal Halide Lamp
5
Full Spectrum Lamps
6
The Secret is in the Shape
7
Additional Protection
8
Energy Saving Lamps
9
Designer Colour 10 ®
White-Lux® Plus HPS Replacement Lamps
11
Specialists in Metal Halide Technology
12
Open Rated Horizontal Lamps
13
White-Lux Plus Lamps
14
Uni-Form® Pulse Start Enclosed Rated Lamps
16
®
Uni-Form® Pulse Start Open Rated Lamps
18
Natural White® Lamps
20
Euro Metal Halide Lamps
22
Standard Metal Halide Probe Start Lamps
24
High Wattage Double Ended Lamps
27
Double Ended & G12 Lamps
28
Ceramic Master-PLUS Metal Halide Lamps
30
Designer Colour® Lamps
32
Aquatic and Special Purpose Lamps
34
Ventronic HID Control Gear
36
Technical Information Description Codes and Ordering Information Glossary of Terms Index
39-49 50 52 54-59
Venture Lighting – Asia Pacific Venture maintains a worldwide network of manufacturing facilities. Venture Lighting products are distributed by the Advanced Lighting Technologies group of companies in Australia, New Zealand and Singapore. The Advanced Lighting offices provide sales, technical and administrative support to a wide range of customers from engineers, specifiers, OEM’s, wholesalers and end users. Our Asia Pacific head office is located in Melbourne, Australia, as well as offices in Singapore and Auckland, and a network of representatives, agents and distributors located throughout Australia, New Zealand and Asia. We believe that the best products in Metal Halide today should be complemented by the very best service and support. See the ‘Contact Us’ details at the back of this catalogue for all your sales and service information.
6
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Quality
Venture
Simply a Better Metal Halide Lamp Colour Uniformity - MacAdam Ellipses
• Exclusive formed body arc tube for consistency beyond ceramic metal halide • Patented stronger weldless mount construction to minimise delivery and handling breakages • ‘Tipless’ arc tube improves performance for maximum colour and light output uniformity
.032 .024 .016 .008
CCY
0
-.008
Performance
-.016
• Longer lamp life
-.032 -.032
-.024
-.024
-.016
-.008
0
.008
.016
.024
.032
CCX
• Enhanced lumen maintenance Standard MH 10-step ellipse
Ceramic MH 6-step ellipse
Uni-Form® MH 4-step ellipse
• Hot restart in less than half the time of standard pinch body metal halide systems • 50% faster warm-up
Safety
Lamps
• Excellent system colour uniformity
• Shrouded ‘open-rated’ lamps provide protection for luminaires without lenses • UV Shield® blocks up to 80% UV, 50% more than most UV reducing lamps • Reduces UV damage to merchandise and signage Exclusive tipless arc tube Improves performance for maximum colour and light output uniformity
Selection • Venture’s Uni-Form® pulse start series of lamps has the greatest selection of lumen packages: 50W to 1000W
Unique formed body arc tube Shaped to follow the curve of the arc stream to deliver superior lamp efficacy
• Most comprehensive range of open-rated products available in the industry
Safety shroud with UV Shield® Blocks up to 80% UV, 50% more than most UV-reducing lamps to prevent polycarbonate fixtures from yellowing
Patented stronger weldless mount construction No welds mean less breakage during shipping and handling
7
Natural White
Full Spectrum
• More consistent lamp to lamp colour
New Natural White® lamps offer light output in all parts of the visual spectrum to provide better colour than ceramic metal halide lamps.
• Light output in all parts of the visual spectrum
With Natural White® lamps, blues are true blue and reds are more vibrant; whites are whiter and skin tones look like they’re under sunlight.
• Excellent colour uniformity and stability for the life of the lamp • Provides better colour than ceramic metal halide
Ceramic Metal Halide 4000K - 90 CRI
• Ideal for daylight harvesting applications • Lamps feature superior Uni-Form® pulse start technology
Uni-Form® Natural White® 5000K - 90+ CRI
Compact Fluorescent 3500K - 80 CRI
8
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Pinch Fin
Venture’s Unique Formed Body Arc Tube Technology
Electrode
• Superior colour uniformity, less deviation from lamp to lamp - consistency beyond ceramic metal halide
Start Electrode
Arc Chamber Exhaust Tip
Venture
The Secret is in the Shape
• Highest lamp efficacy • Patented stronger weldless arc tube mounting technology • Higher maintained lumens, longer lamp life
Electrode
• Hot restart in less than half the time of regular metal halide • 50% faster warm-up
Pinch Fin
Lamps
The Tipless Difference Unique formed body arc tube Shaped to follow the curve of the arc stream delivering superior lamp efficacy. Exclusive tipless arc tube Totally uniform shape further improves performance colour and light output uniformity.
9
Metal Halide Protected Lamps
Open Luminaire Rated Protected Lamps
Open Rated Lamps
Incorporating an internal shroud to prevent the outer envelope from shattering in the unlikely event of a lamp malfunction. • Arc tube surrounded by an internal shroud
Open fixtures offer significant advantages over enclosed fixtures. They do not require cover lenses which reduce light output and accumulate dirt. Enclosed fixtures make lamp replacements more difficult. For safety, open fixtures need open rated metal halide lamps.
• Continuous operation, no shut off required • Eliminates the need for a luminaire lens, to provide more light
UV-Shield® the solution to polycarbonate yellowing Incorporating an impregnated quartz shroud to absorb ultraviolet light.
With UV-Shield®
Without UV-Shield®
• Prevents ‘yellowing’ of polycarbonate lenses • Blocks up to 80% of damaging UV Light • Can extend the life of the fitting lens up to 10 times
Australia New Zealand 10 Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Venture Lamps
Pulse Start = Energy Saving Lamps Energy Saving Achieve Almost 50% There is now a rapidly growing demand for even more energy efficient lighting systems to help the environment. Venture Lighting is leading the way worldwide in developing innovative, new energy efficient lighting products to help reduce overall energy usage costs but without compromising on lighting quality. Now, Venture’s pulse start metal halide lighting systems are widely regarded as the most advanced available. They offer more light than conventional systems, excellent colour uniformity, longer life and - most important of all significant energy savings.
Venture Lighting is leading the way worldwide in developing innovative, new energy efficient lighting...
11
Designer Colour ® Lamps No Filters, No Gels
Venture’s Designer Colour® range is unique. Now you can achieve superb primary colour generation without the need for filters or gels. No filtration is involved in the generation of colour. Instead, the metal halides in the arc tube are selected for their ability to generate individual saturated colours. Their advanced chemistry ensures excellent colour uniformity both when the lamps are new and throughout their lives. Designer Colour® lamps operate on standard ballasts and allow the designer to convert any standard fixture into one rich colour.
• Available in 70, 150, 250, 400 and 1000W • Choose from Green, Blue, Pink and Magenta • High efficiency - fewer fixtures required • Compact size • Good optical control
Australia New Zealand 12 Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 www.venturelighting.com.au www.venturelighting.co.nz +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339 www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Venture
White-Lux® Plus
HPS Replacement Lamps Lamps
It’s quick and simple to get rid of old, high-pressure sodium lighting with White-Lux® Plus Metal Halide lamps from Venture Lighting.
HPS Replacement Lamps
White-Lux Plus lamps can operate directly from existing HPS control gear.
• Venture’s unique Uni-Form® formed body arc tube
®
• From the world leaders in metal halide technology • Faster warm-up and hot restart • Increased efficiency • Long life - 10,000 hours + • Better lamp-to-lamp consistency • A full range of ratings from 50 to 400 watts • A choice of tubular and elliptical designs • Clear or coated outer jackets • For use in open or enclosed fittings • No thermal cut-out ballasts required • Environmentally friendly UV-Shield® is available for fittings with poly-carbonate lenses
So why put up with murky yellow-tinged sodium lighting when it’s never been easier or more cost effective to switch - and enjoy the clean, fresh and natural white light of metal halide lamp technology!
13
Specialists in Metal Halide Technology The Venture product range includes:
Whatever your metal halide requirements may be, Venture Lighting can provide an unequalled, quality ‘one stop’ solution, with a range larger than all other manufacturers combined…
• Uni-Form® pulse start systems, which offer a 22% increase in lumens per watt over other metal halide lamps, as well as providing outstanding uniformity of performance. • White-Lux® metal halide lamps to provide a direct retrofit for traditional yellow HPS (SON) lamps. A very economical way to migrate to pure clean white light. • A unique range of energy saving lamps offering savings of up to 30% on conventional metal halide systems. • A range of Euro and Probe Start metal halide lamps – fully compatible with mercury ballasts when used with a metal halide ignitor offering exceptional value for money. • Single and double-ended metal halide lamps that promise an outstanding 10,000 hour lamp life. Most similar products can barely manage 6,000 hours! • Designer Colour® metal halide lamps that provide excellent primary colour generation with no need for filtration. Their high efficiency means fewer fixtures are needed - and they operate on standard ballasts.
A unique range of energy saving lamps offering savings of up to 30% on conventional metal halide systems
Australia New Zealand 14 Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz Email: sales@venturelighting.com.sg
Open Rated Horizontal Lamps in 200, 250, 350 and 400 wattages offer clear lamps with UV-Shield® for Horizontal operation in open luminaires.
Open Rated Watts
Features
Applications
• Clear lamps with UV-Shield for horizontal operation in open luminaires
• • • •
®
Low Bay luminaires for warehouses Retail sheds Showrooms Commercial and industrial
Pulse Start Control Gear
Tubular
Lamp Description
Product No.
Venture
Open Rated Horizontal Lamps
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
200
HIPT 200W/H75/UVS/T52/PS/740
59473
19000
15000
4000
2-3
3-5
68
Clear
HOR±75°
A
12
250
HIPT 250W/H75/UVS/T52/PS/740
79483
22000
20000
4000
2-3
3-5
68
Clear
HOR±75°
A
12
350
HIPT 350W/H75/UVS/T52/PS/740
56238
33000
26000
4000
2-3
3-5
68
Clear
HOR±75°
B
12
400
HIPT 400W/H75/UVS/T52/PS/740
35982
38000
26000
4000
2-3
3-5
68
Clear
HOR±75°
B
12
Watts
Pulse Start Control Gear
Eliptical
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250
MP 250W/H75/UVS/PS/740
49822
23100
20000
4000
2-3
4-6
68
Clear
HOR±75°
C
12
350
MP 350W/H75/UVS/PS/740
65218
32000
26000
4000
2-3
5-8
68
Clear
HOR±75°
D
6
400
MP 400W/H75/UVS/PS/740
17611
38000
26000
4000
2-3
5-8
68
Clear
HOR±75°
D
6
A T52 Dia. = 52 mm MOL = 211 mm LCL = 132 mm Base = E40
T52 Dia. = 52 mm MOL = 225 mm LCL = 146 mm Base = E40
C ED28/90
D ED37/120
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = EX39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Open Rated Horizontal Lamps
Open Rated
15
White-Lux® Plus White-Lux® Plus metal halide lamps in 50 to 1000 wattages offer increased lumen efficiency over existing White-Lux metal halide lamps. These lamps can be used to convert the harsh yellow light of sodium lamps in existing installations to clean white metal halide light.
Features
Applications
• • • •
• • • • • •
High lumen efficiency Long lamp life Enclosed and open fixture designs Uni-Form® formed body arc tube for faster starting • UV-Shield® option available (UVS)
They also provide the added benefit of a formed body arc tube for faster starting. White-Lux® Plus metal halide lamps operate on standard HPS ballasts and ignitors.
Floodlighting Retail warehouses Factories Security lighting Car Parks Showrooms/Warehouses
Enclosed Rated
HPS Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
50 70 70 70
HIE 50W/U/LU/4K HIE 70W/U/LU/4K HIE 70W/C/U/LU/4K HIE 70W/U/LU/3K
67331 27373 63173 23660
3400V 5600V 5300V 5600V
10000V 15000V 15000V 15000V
4000 4000 3700 3200
1-2 1-2 1-2 1-2
1-2 1-2 1-2 1-2
68 68 70 68
Clear Clear Coated Clear
U U U U
A A A A
12 12 12 12
70 100 100 100 100 150 150 150
HIE 70W/C/U/LU/3K HIE 100W/U/LU/4K HIE 100W/C/U/LU/4K HIE 100W/U/LU/3K HIE 100W/C/U/LU/3K HIE 150W/U/LU/4K HIE 150W/C/U/LU/4K HIE 150W/C/U/LU/3K
96720 50340 19031 79457 45157 30544 40563 69876
5300V 9000V 8500V 9000V 8500V 14000V 13300V 13300V
15000V 15000V 15000V 15000V 15000V 15000V 15000V 15000V
3200 4000 3700 3200 3200 4000 3700 3700
1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2
1-2 2-4 2-4 2-4 2-4 2-4 2-4 2-4
70 68 70 68 70 68 70 70
Coated Clear Coated Clear Coated Clear Coated Coated
U U U U U U U U
A A A A A A A A
12 12 12 12 12 12 12 12
Open Rated
16
HPS Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
70 70 70 70
HIPE 70W/C/U/LU/UVS/3K HIPE 70W/C/V/LU/UVS/27K HIPE 70W/U/LU/UVS/4K HIPE 70W/C/U/LU/UVS/4K
52910 48692 10002 10003
5000V 5000V 5300V 5000V
15000V 15000V 15000V 15000V
3200 2700 4000 3700
1-2 1-2 1-2 1-2
2-4 2-4 2-4 2-4
70 70 68 70
Coated Coated Clear Coated
U V±15° U U
B B B B
12 12 12 12
100 100 100 100 100 100 150 150
HIPE 100W/U/LU/UVS/3K HIPE 100W/C/U/LU/UVS/3K HIPE 100W/C/V/LU/UVS/27K HIPE 100W/U/LU/UVS/4K HIPE 100W/C/U/LU/UVS/4K HIPE 100W/U/LU/E90/UVS/4K HIPE 150W/U/LU/UVS/3K HIPE 150W/C/U/LU/UVS/3K
82539 65850 39468 10004 10005 10050 22822 22833
8500V 8100V 8100V 8500V 8100V 8500V 13300V 12600V
15000V 15000V 15000V 15000V 15000V 15000V 15000V 15000V
3200 3200 2700 4000 3700 4000 3200 3200
1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2
3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5
68 70 70 68 70 68 68 70
Clear Coated Coated Clear Coated Clear Clear Coated
U U V±15° U U U U U
B B B B B C B B
12 12 12 12 12 12 12 12
150 150 150 150 150
HIPE 150W/C/V/LU/UVS/27K HIPE 150W/U/LU/E90/UVS/4K HIPE 150W/C/U/LU/E90/UVS/4K HIPE 150W/U/LU/UVS/4K HIPE 150W/C/U/LU/UVS/4K
41700 10051 10082 10006 10007
12600V 13300V 12600V 13300V 12600V
15000V 15000V 15000V 15000V 15000V
2700 4000 3700 4000 3700
1-2 1-2 1-2 1-2 1-2
3-5 3-5 3-5 3-5 3-5
70 68 70 68 70
Coated Clear Coated Clear Coated
V±15° U U U U
B C C B B
12 12 12 12 12
A ED17/54
B EXD17/54
C ED28/90
D ED28/90
E ED37/120
F BT37/120
G
H T38
Dia. = 54 mm MOL = 141 mm LCL = 89 mm Base = E27
Dia. = 54 mm MOL = 141 mm LCL = 89 mm Base = E27
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = EX39
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = E40
Dia. = 120 mm MOL = 296 mm LCL = 182 mm Base = E40
Dia. = 120 mm MOL = 296 mm LCL = 182 mm Base = E40
Dia. = 120 mm MOL = 296 mm LCL = 182 mm Base = E40
Dia. = 38 mm MOL = 156 mm LCL = 102 mm Base = E27
Watts
HPS Control Gear
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos Fig.
Ctn Qty
250
HIE 250W/V/LU/4K
31668
22000
20000
4000
2-3
3-5
68
Clear
V±15°
D
12
250
HIE 250W/C/V/LU/4K
56266
21000
20000
3700
2-3
3-5
70
Coated
V±15°
D
12
250
HIE 250W/C/H75/LU/4K
43634
20000
20000
3700
2-3
4-6
70
Coated
HOR±75°
D
12
400
HIE 400W/V/LU/4K
60112
44000
20000
4000
2-3
4-6
68
Clear
V±15°
E
6
400
HIE 400W/C/V/LU/4K
54695
42000
20000
3700
2-3
4-6
70
Coated
V±15°
E
6
400
HIE 400W/C/H75/LU/4K
68110
38000
20000
3700
2-3
5-8
70
Coated
HOR±75°
E
6
1000
HIE 1000W/V/LU/BT120/4K
00154
90000
8000
4000
2-3
10-15
68
Clear
V±15°
F
6
HPS Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250
HIPE 250W/HBU/LU/UVS/4K
10016
21000V
20000V
4000
2-3
5-8
68
Coated
BU±90°
C
12
250
HIPE 250W/C/HBU/LU/UVS/4K
10076
20000V
20000V
3700
2-3
4-6
70
Coated
BU±90°
C
12
250
HIPE 250W/C/H75/LU/UVS/4K
29486
20000
20000
3700
2-3
4-6
70
Coated
HOR±75°
C
12
400
HIPE 400W/V/LU/UVS/4K
10077
42000
20000
4000
2-3
5-8
68
Clear
BU±15°
G
6
HIPE 400W/C/V/LU/UVS/4K
10043
40000
20000
3700
2-3
5-8
70
Coated
BU±15°
G
6
HIPE 400W/C/H75/LU/UVS/4K
40511
38000
20000
3700
2-3
5-8
68
Clear
HOR±75°
G
6
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos
HPS Control Gear
Open Rated (High Output) Lamp Description
Fig.
Ctn Qty
400
HIPE 400W/V/LU/UVS/HO/4K
54918
47000
20000
4000
2-3
5-8
68
Clear
V±15°
G
6
400
HIPE 400W/C/V/LU/UVS/HO/4K
42068
45000
20000
3700
2-3
5-8
70
Coated
V±15°
G
6
Enclosed Rated Watts
HPS Control Gear
White-Lux Tubular
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
70
HIT 70W/U/LU/4K
13742
5300V
15000V
4000
1-2
1-2
68
Clear
U
H
12
100
HIT 100W/U/LU/T38/4K
76738
9000V
15000V
4000
1-2
2-4
68
Clear
U
H
12
100
HIT 100W/U/LU/T46/4K
87368
9000V
15000V
4000
1-2
2-4
68
Clear
U
I
12
150
HIT 150W/U/LU/T38/4K
62272
14000V
15000V
4000
1-2
2-4
68
Clear
U
H
12
150
HIT 150W/U/LU/T46/4K
71144
14000V
15000V
4000
1-2
2-4
68
Clear
U
I
12
250
HIT 250W/U/LU/4K
48768
19000V
10000V
4000
3-5
5-10
68
Clear
U
J
12
250
HIT 250W/U/LU/5K
10855
16800V
10000V
5200
3-5
5-10
75
Clear
U
J
12
250
HIT 250W/H75/LU/4K
27965
20000
15000
4000
3-5
5-10
68
Clear
HOR±75°
K
12
400
HIT 400W/U/LU/4K
98748
36000V
20000V
4000
3-5
5-10
68
Clear
U
L
12
400
HIT 400W/U/LU/5K
21044
32000V
20000V
5200
3-5
5-10
75
Clear
U
L
12
400
HIT 400W/H75/LU/4K
43898
40000
15000
4000
3-5
5-10
68
Clear
HOR±75°
M
12
600
HIT 600W/U/LU/4K
54631
55000V
12000V
4000
3-5
5-10
68
Clear
BU±90°
N
6
1000
HIT 1000W/U/LU/4K
83265
90000V
8000V
4000
3-5
10-15
68
Clear
U
O
6
1000
HIT 1000W/U/LU/5K
00083
80000V
8000V
5000
3-5
10-15
68
Clear
U
O
6
I T15/46
J T15/46
K T15/46
L T15/46
M T15/46
Dia. = 46 mm MOL = 211 mm LCL = 132 mm Base = E40
Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40
Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40
Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40
Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40
T25/76 Dia. = 76 mm MOL = 283 mm LCL = 175 mm Base = E40
White-Lux® Plus
400 400
Watts
Venture
Enclosed Rated
O T25/76 Dia. = 120 mm MOL = 340 mm LCL = 220 mm Base = E40
17
Uni-Form® Pulse Start - Enclosed Rated The Uni-Form® Pulse Start 150 to 1000 Watts Metal Halide lamps. These lamps operate on reactor/ignitor ballast systems specifically designed to realise the best performance from these light sources, including longer life and better lumen maintenance. These lamps are designed for use in enclosed fixtures.
Features
Applications
• • • • • • •
• Warehouses • Retail sheds • Showrooms and other commercial and industrial applications.
Higher lumens vs. standard designs System savings, up to 50 watts Longer life (up to 30,000 hours) Faster warm-up and hot restrike Improved lumen maintenance Reduced colour shift Better cold temperature starting (-40°C)
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
150 150
MH 150W/U/ED28/PS/740 MH 150W/C/U/ED28/PS/737
13556 21344
14000V 13300V
10500V 10000V
15000V 15000V
4000 3700
3-5 3-5
5-10 5-10
68 70
Clear Coated
U U
A A
12 12
Pulse Start Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
200 200 200 200 200
MS 200W/BU/MED/PS/740 MS 200W/C/BU/MED/PS/737 MS 200W/V/PS/740 MS 200W/C/V/PS/737 MS 200W/H75/T15/PS/740
60811 60812 57739 70345 70764
21000 20000 21000 20000 19000
16800 16000 16800 16000 15200
12000 12000 20000 20000 15000
4000 3700 4000 3700 4000
1-2 1-2 1-2 1-2 1-2
2-4 2-4 2-4 2-4 2-4
68 70 68 70 68
Clear Coated Clear Coated Clear
V±15° V±15° V±15° V±15° HOR±75°
B B A A D
12 12 12 12 12
Pulse Start Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250 250 250
MS 250W/V/PS/740 MS 250W/C/V/PS/737 MS 250W/H75/PS/740 MS 250W/H75/T15/PS/740
49621 81365 81054 57625
25000 23800 22000 22000
20000 19000 17600 17600
20000 20000 20000 20000
4000 3700 4000 4000
2-3 2-3 2-3 2-3
3-5 3-5 3-5 3-5
68 70 68 68
Clear Coated Clear Clear
V±15° V±15° HOR±75° HOR±75°
A A C D
12 12 12 12
Pulse Start Control Gear
Enclosed Rated
18
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
320 320 320 320 320 320 320 320
MS 320W/V/ED28/PS/740 MS 320W/C/V/ED28/PS/737 MS 320W/V/ED37/PS/740 MS 320W/C/V/ED37/PS/737 MS 320W/H75/ED28/PS/740 MS 320W/C/H75/ED28/PS/737 MS 320W/H75/T15/L/PS/740 MS 320W/H75/T15/S/PS/740
59194 77594 52236 67712 47549 12758 79710 57626
33000 31000 33000 31000 30000 27000 30000 30000
26000 25000 26000 25000 24000 21000 24000 24000
30000 30000 30000 30000 26000 26000 26000 26000
4000 3700 4000 3700 4000 3700 4000 4000
2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3
5-8 5-8 5-8 5-8 5-8 5-8 5-8 5-8
68 70 68 70 68 70 68 68
Clear Coated Clear Coated Clear Coated Clear Clear
V±15° V±15° V±15° V±15° HOR±75° HOR±75° HOR±75° HOR±75°
A A E E C C G D
12 12 6 6 12 12 12 12
A ED28/90
B ED17/54
C ED28/90
D T15/46
E ED37/120
Dia. = 90mm MOL = 211 mm LCL = 127 mm Base = E39
Dia. = 54 mm MOL = 138 mm LCL = 86 mm Base = E26
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = E39
Dia. = 46 mm MOL = 248 mm LCL = 146 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Pulse Start Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
350 350 350 350 350 350
MS 350W/V/PS/740 MS 350W/C/V/PS/737 MS 350W/V/ED28/PS/740 MS 350W/C/H75/PS/737 MS 350W/H75/ED28/PS/740 MS 350W/H75/T15/PS/740
98389 71329 52980 64866 46959 93749
37000 35000 37000 31000 33000 33000
29000 28000 29000 25000 26000 26000
30000 30000 30000 26000 26000 26000
4000 3700 4000 3700 4000 4000
2-3 2-3 2-3 2-3 2-3 2-3
4-6 4-6 4-6 4-6 4-6 4-6
68 70 68 70 68 68
Clear Coated Clear Coated Clear Clear
V±15° V±15° V±15° HOR±75° HOR±75° HOR±75°
E E A F C G
6 6 12 6 12 12
Venture
Enclosed Rated
Pulse Start Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400 400 400 400 400 400 400
MS 400W/V/PS/740 MS 400W/C/V/PS/737 MS 400W/V/ED28/PS/740 MS 400W/C/V/ED28/PS/737 MS 400W/H75/PS/740 MS 400W/H75/ED28/PS/740 MS 400W/C/H75/ED28/PS/737
73531 42401 85260 46416 58788 40124 55459
44000 42000 44000 42000 40000 40000 38000
35000 33000 35000 33000 32000 32000 30000
30000 30000 30000 30000 26000 26000 26000
4000 3700 4000 3700 4000 4000 3700
2-3 2-3 2-3 2-3 2-3 2-3 2-3
4-6 4-6 4-6 4-6 4-6 4-6 4-6
68 70 68 70 68 68 70
Clear Coated Clear Coated Clear Clear Coated
V±15° V±15° V±15° V±15° HOR±75° HOR±75° HOR±75°
E E A A F C C
6 6 12 12 6 12 12
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
450 450
MS 450W/V/PS/740 MS 450W/C/V/PS/737
10079 10138
50000 47000
40000 37000
30000 30000
4000 3700
2-3 2-3
4-6 4-6
68 70
Clear Coated
V±15° V±15°
E E
6 6
Pulse Start Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
875 875 875
MS 875W/BU/BT37/PS/740 MS 875W/BD/BT37/PS/740 MS 875W/H75/BT37/PS/740
22619 35426 74892
100000 100000 90000
80000 80000 72000
26000 26000 15000
4000 4000 4000
3-5 3-5 3-5
8-12 8-12 8-12
68 68 68
Clear Clear Clear
BU +/-15° H BD +/-15° H HOR±75° I
Ctn Qty 6 6 6
Pulse Start Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
1000 1000
MS 1000W/BU/BT37/PS/740 MS 1000W/HOR/T25/PS/734
71722 49111
115000 110000
86000 77000
12000 5000
4000 3400
3-5 3-5
8-12 10-15
68 68
Clear Clear
BU +/-15° H HOR±75° J
Ctn Qty 6 6
*Note: A range of special UPS lamps are available for use on electronic control gear. Contact our sales office for details.
F ED37/120
G T15/46
H BT37/120
I BT37/120
J T15/46
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 46 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 79 mm MOL = 292 mm LCL = 178 mm Base = E39
Uni-Form® Pulse Start - Enclosed Rated
Pulse Start Control Gear
Enclosed Rated
19
Uni-Form® Pulse Start - Open Rated The Uni-Form® Pulse Start 150 to 875 Watts Metal Halide lamps. These lamps operate on reactor/ignitor ballast systems specifically designed to realise the best performance from these light sources, including longer life and better lumen maintenance. These lamps can be operated safely in open fixtures.
Features
Applications
• • • • • • • • •
• • • •
Higher lumens vs. standard designs System savings, up to 50 watts Longer life (up to 30,000 hours) Faster warm-up and hot restrike Improved lumen maintenance Reduced colour shift Better cold temperature starting (-40°C) UV-Shield® option available (UVS) Open rated
Petrol station canopies Factories Warehouses Large retail areas
Pulse Start Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
150 150
MP 150W/U/ED28/UVS/PS/740 MP 150W/C/U/ED28/UVS/PS/737
58963 32147
13300V 12600V
10000V 9500V
15000V 15000V
4000 3700
3-5 3-5
5-10 5-10
68 70
Clear Coated
U U
A A
12 12
Pulse Start Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
200 200 200
MP 200W/V/UVS/PS/740 MP 200W/C/V/UVS/PS/737 MP 200W/C/V/UVS/PS/732
22147 59174 44872
20000 19000 19000
16000 15200 15200
20000 20000 20000
4000 3700 3200
1-2 1-2 1-2
3-5 3-5 3-5
68 70 70
Clear Coated Coated
V±15° V±15° V±15°
A A A
12 12 12
Pulse Start Control Gear
Open Rated Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
250 250 250
MP 250W/BU/UVS/PS/740 MP 250W/C/BU/UVS/PS/737 MP 250W/H75/UVS/PS/740
64658 32658 49822
23800 22600 21300
19000 18000 17000
20000 20000 20000
4000 3700 4000
2-3 2-3 2-3
4-6 4-6 4-6
68 70 68
Clear Coated Clear
BU+/-15° A BU+/-15° A HOR±75° B
Ctn Qty 12 12 12
Pulse Start Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
320 320 320 320 320
MP 320W/BU/ED28/UVS/PS/740 MP 320W/C/BU/ED28/UVS/PS/737 MP 320W/BU/ED37/UVS/PS/740 MP 320W/C/BU/ED37/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/732
10103 10104 21714 32795 66506
31000 29000 31000 29000 29000
25000 23000 25000 23000 23000
30000 30000 30000 30000 30000
4000 3700 4000 3700 3200
2-3 2-3 2-3 2-3 2-3
4-6 4-6 4-6 4-6 4-6
68 70 68 70 70
Clear Coated Clear Coated Coated
BU+/-15° BU+/-15° BU+/-15° BU+/-15° BU+/-15°
A A C C C
12 12 6 6 6
Pulse Start Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
350 350 350 350 350 350
MP 350W/V/UVS/PS/740 MP 350W/C/V/UVS/PS/737 MP 350W/C/V/UVS/PS/732 MP 350W/V/ED28/UVS/PS/740 MP 350W/C/V/ED28/UVS/PS/737 MP 350W/H75/UVS/PS/740
22149 44097 27845 47887 55401 65218
35000 33000 33000 35000 33000 32000
28000 26000 26000 28000 26000 23800
30000 30000 30000 30000 30000 26000
4000 3700 3200 4000 3700 4000
2-3 2-3 2-3 2-3 2-3 2-3
5-8 5-8 5-8 5-8 5-8 5-8
68 70 70 68 70 68
Clear Coated Coated Clear Coated Clear
V±15° V±15° V±15° V±15° V±15° HOR±75°
C C C A A D
6 6 6 12 12 6
Pulse Start Control Gear
Open Rated - Magnetic Dimming
20
Fig.
Watts
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
350
MP 350W/C/V/MD/UVS/PS
72834
33000
26000
26000
3700
2-3
5-8
70
Coated
V±15°
C
6
A ED28/90
B ED28/90
C ED37/120
D ED37/120
E BT37/120
Dia. = 90mm MOL = 211 mm LCL = 127 mm Base = EX39
Dia. = 90mm MOL = 211 mm LCL = 127 mm Base = EX39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Pulse Start Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400 400 400 400 400
MP 400W/V/UVS/PS/740 MP 400W/C/V/UVS/PS/737 MP 400W/V/ED28/UVS/PS/740 MP 400W/C/V/ED28/UVS/PS/737 MP 400W/H75/UVS/PS/740
71642 45541 12445 88648 17611
41000 39000 41000 39000 38000
33000 31000 33000 31000 30000
30000 30000 30000 30000 26000
4000 3700 4000 3700 4000
2-3 2-3 2-3 2-3 2-3
5-8 5-8 5-8 5-8 5-8
68 70 68 70 68
Clear Coated Clear Coated Clear
V±15° V±15° V±15° V±15° HOR±75°
C C A A D
6 6 12 12 6
*
Open Rated - Magnetic Dimming
Pulse Start Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400
MP 400W/C/V/MD/UVS/PS
84629
40000
32000
26000
3700
2-3
5-8
70
Coated
V±15°
C
6
*
Open Rated
Pulse Start Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
450 450
MP 450W/BU/UVS/PS/740 MP 450W/C/BU/UVS/PS/737
65072 59216
47000 45000
37000 36000
30000 30000
4000 3700
2-3 2-3
5-8 5-8
68 70
Clear Coated
BU+/-15° C BU+/-15° C
*
Fig.
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
875 875
MP 875W/BU/BT37/PS/740 MP 875W/C/BU/BT37/PS/737
58953 41686
95000 90000
76000 72000
26000 26000
4000 3700
3-5 3-5
8-12 8-12
68 70
Clear Coated
BU+/-15° E BU+/-15° E
Fig.
Open fixtures need Pink EX39 sockets that only accept ‘open rated’ lamps in order to prevent accidental use of ‘enclosed rated’ lamps.
Enclosed Rated Lamp The extended centre contact completes the circuit in the socket.
EX39 Socket
6 6
Pulse Start Control Gear
Watts
Open Rated Lamp
Ctn Qty
The standard centre contact won’t reach the contact in the dedicated socket.
Ctn Qty 6 6
Uni-Form® Pulse Start - Open Rated
Open Rated
Venture
*
Open Rated
EX39 Socket
21
Natural White® Natural like sunlight, Natural White® provide superior colour rendering. With Venture’s Natural White® pulse start metal halide systems, blues are true blue, reds are more vibrant, whites are whiter, and skin tones look like they’re under the sun. Natural White® lamps, with a colour temperature of 5000K and a CRI of 90+, Venture’s Natural White® lamps clearly brings daylight indoors.
Open Rated
Features
Applications
• Lamps with improved Colour Rendering Index • (Ra) for high bay luminaires without protective cover glasses • UV-Shield® • Open Rated
• Retail stores • Commercial and Industrial • Museums, Art Galleries
Natural White®
Pulse Start Control Gear
Watts
Lamp Description
Product No.
Initial Outdoor Initial Indoor Initial Photopic Avg. Life CCT (K) Lumens Lumens Lumens Hours
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250 320 320 320 320 320 350 350 350 400 400 400
MP 250W/BU/UVS/PS/EM/950 MP 250W/C/BU/UVS/PS/EM/950 MP 320W/BU/ED28/UVS/PS/EM/950 MP 320W/BU/ED37/UVS/PS/EM/950 MP 320W/C/BU/ED37/UVS/PS/EM/950 MP 320W/H75/T15/S//UVS/PS/EM/950 MP 320W/H75/T15/L//UVS/PS/EM/950 MP 350W/BU/ED28/UVS/PS/EM/950 MP 350W/BU/UVS/PS/EM/950 MP 350W/C/BU/UVS/PS/EM/950 MP 400W/BU/ED28/UVS/PS/EM/950 MP 400W/BU/UVS/PS/EM/950 MP 400W/C/BU/UVS/PS/EM/950
19523 19525 98530 98520 95123 95320 95321 33149 51628 38197 72315 57129 89410
21000 19500 28500 28500 27500 28500 28500 30500 30500 25500 36000 36000 30000
90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+ 90+
Clear Coated Clear Clear Coated Clear Clear Clear Clear Coated Clear Clear Coated
BU±15° BU±15° BU±15° BU±15° BU±15° HOR±75° HOR±75° BU±15° BU±15° BU±15° BU±15° BU±15° BU±15°
A A A B B C D A B B A B B
12 12 12 6 6 12 12 12 6 6 12 6 6
• Superior colour rendering - objects appear as they would outdoors • Work spaces look brighter • Tasks, such as reading, become easier to perform • Excellent colour uniformity and stability over life of lamp due to tipless formed body arc tube • Protect merchandise and signage from fading with UV-Shield® technology - Blocks nearly all the UV output • Longer lamp life (up to 30,000 hours)
20000 18500 27000 27000 26000 27000 27000 29000 29000 27000 34500 34500 32500
16500 15500 22500 22500 21500 22500 22500 24000 24000 22500 28500 28500 27000
5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000
• Designed for open luminaires - Shrouded arc tube lamps can operate continuously without weekly shutdowns • 50% faster warm-up time than ceramic or standard metal halide systems • Hot restart in less than half the time of ceramic metal halide lamps • Less breakage during shipping and fewer points of failure due to weldless construction of lamps
* Note: All lamps have a light loss factor (LLF) at 8000 hours of 0.9 Initial Outdoor Nighttime Lumens = Effective lumens multiplier = 1.27 Initial Indoor Visual Task Lumens = Effective lumens multiplier 1.21
22
20000 20000 26000 26000 26000 26000 26000 30000 30000 30000 30000 30000 30000
A ED28/90
B ED37/120
C T15/46S
D T15/46L
Dia. = 90 mm MOL = 215 mm LCL = 131 mm Base = EX39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Dia. = 46 mm MOL = 211 mm LCL = 127 mm Base = EX39
Dia. = 46 mm MOL = 292 mm LCL = 178 mm Base = EX39
E
Venture Natural White
BEFORE
23
Euro Metal Halide Euro Lamps make up a range of metal halide lamps suitable for mercury ballasts with either 600-900 volt 2 wire parallel ignitors, or 3000-4500 volt ignitors.
Features
Applications
• Operates on mercury ballast with standard metal halide ignitor • Vertical and horizontal lamps provide high performance and long life • Tubular and elliptical design • Clear and coated bulb finishes
• Petrol station canopies • Industrial high bay and low bay fittings • Larger retail areas
Metal Halide Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
175 175 175 175 250 250 250 250
HIE 175W/U/E54/EURO/4K HIE 175W/C/U/E54/EURO/4K HIE 175W/U/EURO/4K HIE 175W/C/U/EURO/4K HIE 250W/BU/EURO/4K HIE 250W/C/BU/EURO/4K HIE 250W/U/EURO/4K HIE 250W/C/U/EURO/4K
84971 24729 36279 40698 81203 81202 88246 21303
14000V 13300V 14000V 13300V 23000V 22000V 21000V 20000V
10000V 10000V 10000V 10000V 10000V 10000V 10000V 10000V
4000 3700 4000 3700 4000 3700 4000 3700
3-5 3-5 3-5 3-5 2-4 2-4 3-5 3-5
5-10 5-10 5-10 5-10 5-10 5-10 5-10 5-10
65 70 65 70 65 70 65 70
Clear Coated Clear Coated Clear Coated Clear Coated
U U U U BU±15° BU±15° U U
A A B B B B B B
12 12 12 12 12 12 12 12
Enclosed Rated Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250 250
HIT 250W/U/EURO/4K HIT 250W/U/EURO/5K HIT 250W/HOR/EURO/4K
33950 00033 57712
21000V 19000V 23000
10000V 7500V 10000
4000 5000 4000
3-5 3-5 3-5
5-10 5-10 5-10
65 75 65
Clear Clear Clear
U U HOR±45°
C C D
12 12 12
ED17/54
24
Metal Halide Control Gear
Tubular
Watts
Dia. = 54 mm MOL = 141 mm LCL = 89 mm Base = E27
B ED28/90
C T15/46
D T15/46
E ED37/120
F ED28/90
G
Dia. = 90 mm MOL = 215 mm LCL = 131 mm Base = E40
Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40
Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40PO
Dia. = 120 mm MOL = 296 mm LCL = 182 mm Base = E40
Dia. = 90 mm MOL = 215 mm LCL = 131 mm Base = E40PO
Dia. = 90 mm MOL = 215 mm LCL = 131 mm Base = E40
Watts
Metal Halide Control Gear
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos Fig.
Ctn Qty
400
HIE 400W/BU/EURO/4K
33544
40000
15000
4000
3-5
10-15
68
Clear
BU±15°
E
6
400
HIE 400W/C/BU/EURO/4K
31545
38000
15000
3700
3-5
10-15
70
Coated
BU±15°
E
6
400
HIE 400W/C/HOR/EURO/4K
63958
38000
15000
3700
3-5
10-15
70
Coated
HOR±45°
F
6
400
HIE 400W/U/EURO/4K
20137
36000V
15000V
4000
3-5
8-12
68
Clear
U
E
6
400
HIE 400W/C/U/E90/EURO/4K*
58122
34000V
15000V
3700
3-5
8-12
70
Coated
U
G
12
400
HIE 400W/C/U/EURO/4K
88787
34000V
15000V
3700
3-5
8-12
70
Coated
U
E
6
Venture
Enclosed Rated
* Reduced jacket
Metal Halide Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400
HIPE 400W/BU/EURO/4K
99441
38000
15000
4000
3-5
10-15
68
Clear
BU±15°
H
6
400
HIPE 400W/C/BU/EURO/4K
94102
36000
15000
3700
3-5
10-15
70
Coated
BU±15°
H
6
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
Watts
Metal Halide Control Gear
Tubular
Enclosed Rated Lamp Description HIT 400W/U/EURO/4K
25830
36000V
15000V
4000
3-5
10-15
68
Clear
U
I
12
HIT 400W/U/EURO/5K
00034
32000V
15000V
5000
3-5
10-15
75
Clear
U
I
12
400
HIT 400W/HOR/EURO/4K
88410
40000
15000
4000
3-5
10-15
68
Clear
HOR±45°
J
12
Watts
Metal Halide Control Gear
Tubular
Enclosed Rated Lamp Description
Lamp Current
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
1000
HIT 1000W/HOR/4.5K
9.5
00336
85000
8000
4300
3-5
10-15
65
Clear
HOR±15°
L
6
1000
HIT 1000W/U/EURO/4K
8.2
00008
90000V
8000V
4000
3-5
10-15
68
Clear
U
K
6
1000
HIT 1000W/U/EURO/5K
8.2
00282
80000V
8000V
5000
3-5
10-15
68
Clear
U
K
6
2000
HIT 2000W/U/4K
8.8
00066
230000V
5000V
4000
3-5
10-15
68
Clear
U
M
6
2000
HIT 2000W/U/230V/45K
16.6
00067
185000V
5000V
4500
3-5
10-15
68
Clear
U
M
6
H BT37/120
I T15/46
J T15/46
K T76
L T76
M T100
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E40
Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40
Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40PO
Dia. = 76 mm MOL = 340 mm LCL = 220 mm Base = E40
Dia. = 76 mm MOL = 340 mm LCL = 220 mm Base = E40
Dia. = 100 mm MOL = 420 mm LCL = 220 mm Base = E40
Euro Metal Halide
400 400
25
Standard Metal Halide - Probe Start Direct replacement for ‘Multi-Vapor’ and ‘Super Metal Arc’ lamps. Operate on CWA control gear or ignitor reactor Metal Halide Gear.
Features
Applications
• • • • •
Universal • Floodlighting • Sports lighting • General lighting
Full range of wattages Clear and coated bulb finishes Reduced jacket options Choice of colour temperatures Asymmetric arc tube design allows horizontal ±45° operation • Enclosed Rated and Open Rated
Vertical • Architectural area lighting • Commercial downlighting • Industrial high bay Horizontal • Advertising hoardings • Petrol station canopies • Indoor sports
Metal Halide Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
175 175 175 175 175 175 175
MH 175W/U/MED MH 175W/C/U/MED MS 175W/BU/MED MH 175W/U MH 175W/C/U MS 175W/BU MS 175W/HOR
15556 63187 70310 88791 96627 55087 57330
14000V 13300V 15000 14000V 13300V 15000 15000
9100V 8600V 9800 9100V 8600V 9800 9800
10000V 10000V 10000 10000V 10000V 10000 10000
4000 3700 4000 4000 3700 4000 4000
3-5 3-5 3-5 3-5 3-5 3-5 3-5
5-10 5-10 5-10 5-10 5-10 5-10 5-10
65 70 65 65 70 65 65
Clear Coated Clear Clear Coated Clear Clear
U U BU+/-15° U U BU+/-15° HOR+/-45°
A A A B B B C
12 12 12 12 12 12 12
Metal Halide Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250 250 250 250
MH 250W/U MH 250W/C/U MH 250W/U/5K MS 250W/BU MS 250W/C/BU/3K
63052 61290 27252 36297 18477
21000V 20000V 19000V 23000 20000
13700V 13000V 12400V 15000 13000
10000V 10000V 7500V 10000 10000
4000 3700 5000 4000 3200
3-5 3-5 3-5 3-5 3-5
5-10 5-10 5-10 5-10 5-10
65 70 75 65 70
Clear Coated Clear Clear Coated
U U U BU+/-15° BU+/-15°
B B B B B
12 12 12 12 12
250 250 250 250
MS 250W/HOR MS 250W/HOR/T15/3K MH 250W/U/T15 MS 250W/HOR/T15
94883 54843 33479 88353
23000 21000 21000V 23000
15000 13700 13700V 15000
10000 10000 10000V 10000
4000 3200 4000 4000
3-5 3-5 3-5 3-5
5-10 5-10 5-10 5-10
65 65 65 65
Clear Clear Clear Clear
HOR+/-45° HOR+/-45° U HOR+/-45°
C D E D
12 12 12 12
Metal Halide Control Gear
Enclosed Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400 400 400 400 400 400 400 400 400 400 400 400 400
MH 400W/U/ED28 MH 400W/C/U/ED28 MS 400W/BU/ED28 MS 400W/HOR/ED28 MS 400W/C/HOR/ED28 MH 400W/U MH 400W/C/U MH 400W/U/5K MS 400W/HOR MS 400W/C/HOR MS 400W/HOR/T15 MH 400W/U/T15 MS 400W/HOR/T15/3K
57540 20753 40013 21929 24573 18520 83545 36813 40509 64648 55100 55422 32225
36000V 34000V 40000 40000 38000 36000V 34000V 32500V 40000 38000 40000 36000V 38000
23000V 22000V 26000 26000 24000 23000V 22000V 21000V 26000 24000 26000 23000V 24000
20000V 20000V 20000 20000 20000 20000V 20000V 15000V 20000 20000 15000 15000V 15000
4000 3700 4000 4000 3700 4000 3700 5000 4000 3700 4000 4000 3200
3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5
10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15
65 70 65 65 70 65 70 75 65 70 65 65 65
Clear Coated Clear Clear Coated Clear Coated Clear Clear Coated Clear Clear Clear
U U BU+/-15° HOR+/-45° HOR+/-45° U U U HOR+/-45° HOR+/-45° HOR+/-45° U HOR+/-45°
B B B C C F F F G G H I H
12 12 12 12 12 6 6 6 6 6 12 12 12
A ED17/54
26
Dia. = 54 mm MOL = 138 mm LCL = 86 mm Base = E26
ED28/90 Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = E39
C ED28/90
D T15/46
E T15/46
F ED37/120
G ED37/120
H T15/46
I T15/46
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = EP39(POMB)
Dia. = 46 mm MOL = 211 mm LCL = 127 mm Base = EP39(POMB)
Dia. = 46 mm MOL = 211 mm LCL = 127 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EP39(POMB)
Dia. = 46 mm MOL = 248 mm LCL = 141 mm Base = EP39(POMB)
Dia. = 46 mm MOL = 248 mm LCL = 141 mm Base = E39
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
1000 1000 1000 1000 1000 1000 1000 1000 1000
MH 1000W/U MH 1000W/C/U MH 1000W/U/5K MH 1000W/U/BT37 MS 1000W/BU MS 1000W/BU/BT37 MS 1000W/HOR/BT37/3K MS 1000W/HOR/SPORT 60 MS 1000W/BU/T25
72051 88460 35914 15332 89113 13090 53702 47503 78952
110000V 105000V 80000V 110000V 115000 115000 115000 115000 110000
71000V 68000V 52000V 71000V 74000 74000 86000 86000 66000
12000V 12000V 9000V 12000V 12000 12000 12000 12000 5000
4000 3700 5000 4000 4000 4000 3400 3400 4000
3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5
10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15 10-15
65 70 75 65 65 65 70 70 65
Clear Coated Clear Clear Clear Clear Clear Clear Clear
U U U U BU+/-15° BU+/-15° HOR +/-45° HOR +/-60° BU+/-15°
J J J K J K L M N
6 6 6 6 6 6 6 6 6
Enclosed Rated
Venture
Metal Halide Control Gear
Enclosed Rated
Metal Halide Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
1500 1500 1500 1650
MH 1500W/HBU MH 1500W/U/XL MS 1500W/HOR/XP/SPORT60 MS 1650W/HOR/XP/SPORT60
18360 12342 82070 16419
161000BU 170000V 162000 177000
136000BU 136000V 137700 145000
3000BU/H 6000V 3000 3000
3400 4000 3400 3200
3-5 3-5 3-5 3-5
10-15 10-15 10-15 10-15
65 65 70 70
Clear Clear Clear Clear
BU+/-105° U HOR +/-60° HOR +/-60°
J J M M
6 6 6 6
Metal Halide Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250 400 400
HIE 250W/U/EURO/4K HIE 250W/C/U/EURO/4K HIE 400W/U/EURO/4K HIE 400W/C/U/EURO/4K
88246 21303 20137 88787
21000V 20000V 36000V 34000V
13700V 13000V 23000V 22000V
10000V 10000V 20000V 20000V
4000 3700 4000 3700
3-5 3-5 3-5 3-5
5-10 5-10 8-12 8-12
68 70 68 70
Clear Coated Clear Coated
U U U U
O O P P
12 12 6 6
Open Rated
Metal Halide Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
175 175
MPI 175W/BU MPI 175W/C/BU
32519 32520
14000 13300
9100 8600
10000 10000
4000 3700
3-5 3-5
5-10 5-10
65 70
Clear Coated
BU+/-15° BU+/-15°
Q Q
12 12
Metal Halide Control Gear
Open Rated Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250
MPI 250W/BU MPI 250W/C/BU
60722 60723
21800 20700
14200 13500
10000 10000
4000 3700
3-5 3-5
5-10 5-10
65 70
Clear Coated
BU+/-15° BU+/-15°
Q Q
12 12
Open Rated
Metal Halide Control Gear
Watts
Lamp Description
Product No.
Initial Lumens
Mean Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
400 400
MPI 400W/BU MPI 400W/C/BU
95527 26091
40000 38000
26000 25000
20000 20000
4000 3700
3-5 3-5
10-15 10-15
65 70
Clear Coated
BU+/-15° BU+/-15°
R R
6 6
J BT56/180
K BT37/120
L BT37/120
Dia. = 180 mm MOL = 391 mm LCL = 241mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EP39(POMB)
BT56/180 Dia. = 180 mm MOL = 391 mm LCL = 241mm Base = EP39(POMB)
N T25/76
O ED28/90
P ED37/120
Q ED28/90
R BT37/120
Dia. = 79 mm MOL = 292 mm LCL = 178 mm Base = E39
Dia. = 90mm MOL = 211 mm LCL = 127 mm Base = E40
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = E40
Dia. = 90 mm MOL = 211 mm LCL = 127 mm Base = EX39 27
Dia. = 120 mm MOL = 292 mm LCL = 178 mm Base = EX39
Standard Metal Halide - Probe Start Lamps
Enclosed Rated
27
28
Venture Lighting’s High Wattage sports Lamps are available from 1000 - 2000 Watts. These lamps are the leading choice for arenas and stadiums worldwide.
Features
Applications
• Compact linear lamp for excellent optical control • Cooler base design for improved field performance • High lumen output
• Sports lighting • Stadiums • Large area floodlighting
Venture
High Wattage Lamps
Enclosed Rated Watts
Lamp Description
Lamp Current
Lamp Voltage
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos.
Fig.
Ctn Qty
1000 1500
MBIL S 1000W MBIL S 1500W
4.4 6.7
250 250
22417 22151
80000H 130000H
6000H 6000H
5200 5200
1-2 2-4
5-10 5-10
68 68
Frosted Frosted
HOR±15° HOR±15°
A A
6 6
Reactor Control Gear
Enclosed Rated Lamp Description
Lamp Current
Lamp Voltage
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos.
Fig.
Ctn Qty
2000
MBIL S 2000W
10.3
230
22132
215000H
6000H
5200
10
15
68
Frosted
HOR±15°
B
2
CWA Control Gear
Enclosed Rated Watts
Lamp Description
Lamp Current
Lamp Voltage
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos.
Fig.
Ctn Qty
1500
MH-DE 1500W /T7/4K
3.2
500
46745
150000H
3000H
4000
2-4
5-10
68
Clear
HOR±15°
C
4
Reactor Control Gear Watts
Lamp Description
Lamp Current
2000
MH-TS 2000W/L/K12/4K 10.3
Lamp Voltage
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos.
Fig.
Ctn Qty
220
84203
240000H
5000H
4500
3-5
10-15
68
Clear
HOR±45°
D
2
A MBIL S
B MBIL S
CB MH-DE T7
D MH-TS
Contacts = 256 mm Effective arc length = 168 mm Base = RSC (RX7s)
Contacts = 311 mm Effective arc length = 188 mm Base = SINGLE CONTACT-SPECIAL
Contacts = 256 mm Effective arc length = 168 mm Base = RSC (RX7s)
MOL = 296 mm Nominal Arc Length = 142 mm Base = K12S-36
High Wattage Lamps
Watts
29
Double Ended & G12 Venture Lighting’s BiPin (G12) Lamps are available in 70 to 150 Watts. Venture’s Double Ended Lamps are available in 70 - 250 Watts. These lamps have compact configuration which provides excellent optical control in smaller fixture designs.
Features
Applications
• • • • • •
• • • •
Compact configuration Precise optical control Long life Excellent colour uniformity Uni-Form® formed body arc tube The lamps on this page feature UV-Shield® ultraviolet protection (70, 100 and 150 Watt)
Accent lighting Downlighting Retail environments Showrooms
Enclosed Rated Single Ended (G12 /BiPin) Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
70 70 150 150
HIT 70W/G12/UVS/4K HIT 70W/G12/UVS/3K HIT 150W/G12/UVS/4K HIT 150W/G12/UVS/3K
52983 12108 25779 12106
5600V 5600V 14000V 14000V
10000V 10000V 10000V 10000V
4200 3000 4200 3000
1-2 1-2 1-2 1-2
2-4 2-4 2-4 2-4
70 70 70 70
Clear Clear Clear Clear
U U U U
A A A A
25 25 25 25
Enclosed Rated Double Ended (RSC-RX7s) Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
70 70 70 150 150 150
MH-DE 70W/UVS/4K MH-DE 70W/UVS/3K MH-DE 70W/UVS/FS/6K MH-DE 150W/UVS/4K MH-DE 150W/UVS/3K MH-DE 150W/UVS/FS/6K
60248 16786 79470 74756 11295 29963
5500 5200 4800 11250 11250 11250
10000 10000 10000 10000 10000 10000
4200 3000 6500 4200 3000 6500
1-2 1-2 1-2 1-2 1-2 1-2
2-4 2-4 2-4 2-4 2-4 2-4
70 70 90 70 70 90
Clear Clear Clear Clear Clear Clear
HOR±45° HOR±45° HOR±45° HOR±45° HOR±45° HOR±45°
B B B C C C
25 25 25 25 25 25
Enclosed Rated Double Ended (Fc2)
30
Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
Warm-Up (Min)
Restrike (Min)
RA
Finish
Oper. Pos
Fig.
Ctn Qty
250 250
MH-DE 250W/3K/Fc2 MH-DE 250W/4K/Fc2
84727 72748
20000 20000
10000 10000
3000 4200
2-4 2-4
5-10 5-10
70 70
Clear Clear
HOR±45° HOR±45°
D D
25 25
A G12
B MH-DE
C MH-DE
D MH-De
Dia. = 23 mm MOL = 110 mm LCL = 56 mm Base = G12
MOL = 114.2 mm Base = RSC (R7s)
MOL = 132 mm Base = RSC (Rx7s)
MOL = 163 mm Base = Fc2
Venture Double Ended & G12
31
Ceramic Master-PLUS Metal Halide Ceramic Master-PLUS Metal Halide lamps from Venture offer an unbeatable combination of performance and reliability, as you’d expect from the world’s leading name in Metal Halide technology.
Features
Applications
• Excellent light quality • Exceptional colour rendering and consistency • Increased lamp life • Lower maintenance requirements • Reduced heat output • Significantly less power consumption than halogen equivalents • Ideal for use with quality interior décors
• Commercial including department stores, shops, malls • Offices • Downlighting • Retail environments • Showrooms
Ceramic Lamp G8.5 Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
RA
Oper. Pos
Fig.
Ctn Qty
20
CM-PLUS TC 20W/U/UVS/G8.5/830
00354
1800
9000
3000
80+
U
A
12
20
CM-PLUS TC 20W/U/UVS/G8.5/942
00355
1800
9000
4200
90+
U
A
12
35
CM-PLUS TC 35W/U/UVS/G8.5/830
00356
3400
12000
3000
80+
U
A
12
35
CM-PLUS TC 35W/U/UVS/G8.5/942
00357
3300
12000
4200
90+
U
A
12
70
CM-PLUS TC 70W/U/UVS/G8.5/830
00358
7000
12000
3000
80+
U
A
12
70
CM-PLUS TC 70W/U/UVS/G8.5/942
00359
6600
12000
4200
90+
U
A
12
Ceramic Lamp G12 Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
RA
Oper. Pos
Fig.
Ctn Qty
20
CM-PLUS T 20W/U/UVS/G12/830
00360
1800
10000
3000
80+
U
B
12
20
CM-PLUS T 20W/U/UVS/G12/942
00361
1650
10000
4200
90+
U
B
12
35
CM-PLUS T 35W/U/UVS/G12/830
00362
3400
12000
3000
80+
U
B
12
35
CM-PLUS T 35W/U/UVS/G12/942
00363
3300
12000
4200
90+
U
B
12
70
CM-PLUS T 70W/U/UVS/G12/830
00364
7000
12000
3000
80+
U
C
12
70
CM-PLUS T 70W/U/UVS/G12/942
00365
6600
12000
4200
90+
U
C
12
100
CM-PLUS T 100W/U/UVS/G12/830
00366
9500
12000
3000
80+
U
D
12
100
CM-PLUS T 100W/U/UVS/G12/942
00367
9000
12000
4200
90+
U
D
12
150
CM-PLUS T 150W/U/UVS/G12/830
00368
15000
12000
3000
80+
U
D
12 12
150
CM-PLUS T 150W/U/UVS/G12/942
00369
13500
12000
4200
90+
U
D
Ceramic Lamp MH-DE
32
Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
RA
Oper. Pos
Fig.
Ctn Qty
70
CM-PLUS TD 70W/U/UVS/RX7s/830
00370
7000
15000
3000
80+
U
E
12
70
CM-PLUS TD 70W/U/UVS/RX7s/942
00371
6600
15000
4200
90+
U
E
12
150
CM-PLUS TD 150W/U/UVS/RX7s/830
00372
14000
15000
3000
80+
U
F
12
150
CM-PLUS TD 150W/U/UVS/RX7s/942
00373
12500
15000
4200
90+
U
F
12
A G8.5
B G12
C G12
D G12
E CMP70
F CMP150
Dia. = 14.5 mm MOL = 85 mm LCL = 52 mm Base = G8.5
Dia. = 14.5 mm MOL = 90 mm LCL = 56 mm Base = G12
Dia. = 19 mm MOL = 90 mm LCL = 56 mm Base = G12
Dia. = 19 mm MOL = 100 mm LCL = 56 mm Base = G12
Dia. = 23 mm MOL = 120 mm LCL = 57 mm Base = RX7S
Dia. = 23 mm MOL = 135 mm LCL = 66 mm Base = RX7S
Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
RA
Oper. Pos
Fig.
Ctn Qty
70
CM-PLUS TT 70W/U/UVS/830
00374
7000
18000
3000
80+
U
G
12
70
CM-PLUS TT 70W/U/UVS/942
00375
6600
18000
4200
90+
U
G
12
100
CM-PLUS TT 100W/U/UVS/830
00376
9500
18000
3000
80+
U
H
12
100
CM-PLUS TT 100W/U/UVS/942
00377
9000
18000
4200
90+
U
H
12
U
H
12 12
150 150
CM-PLUS TT 150W/U/UVS/830
00378
CM-PLUS TT 150W/U/UVS/942
14000
18000
3000
80+
00379
13500
18000
4200
90+
U
H
Venture
Ceramic Lamp Tubular
Ceramic Lamp Elliptical Watts
Lamp Description
Product No.
Initial Lumens
Avg. Life Hours
CCT (K)
RA
Oper. Pos
Fig.
Ctn Qty
70
CM-PLUS ED 70W/U/UVS/830
00380
7000
18000
3000
80+
U
I
12
70
CM-PLUS ED 70W/U/UVS/942
00381
6600
18000
4200
90+
U
I
12
100
CM-PLUS ED 100W/U/UVS/830
00382
9500
18000
3000
80+
U
I
12
100
CM-PLUS ED 100W/U/UVS/942
00383
9000
18000
4200
90+
U
I
12
U
I
12
U
I
12
150 150
CM-PLUS ED 150W/U/UVS/830
00384
CM-PLUS ED 150W/U/UVS/942
00385
14000 13500
18000 18000
3000 4200
80+ 90+
Energy Efficient Ceramic Master-PLUS Arc tube
Venture Ceramic lamps are highly energy efficient and offer truly exceptional performance, delivering up to 100 lumens per watt. They therefore consume considerably less energy and generate less heat than a halogen equivalent. Maintenance requirements are reduced too, as the lamps are both robust and reliable and offer a life expectancy of up to 18,000 hours. Excellent Light & Colour
Conventional Arc tube
The quality and consistency of light generated by Venture Metal Halide lamps has always been at the forefront of our design technology. The Venture Ceramic range offers a clean white light and excellent colour rendering, making it ideal for display use and for accentuating quality interiors and decors. Colours, features and textures really stand out. Lamp-to-lamp colour uniformity is comparable to Venture Uni-form速 lamps, so the effect you want is never lost.
G T38
H T46
I E54
Dia. = 38 mm MOL = 156 mm LCL = 102 mm Base = E27
Dia. = 46 mm MOL = 211 mm LCL = 132 mm Base = E40
Dia. = 54 mm MOL = 141 mm LCL = 89 mm Base = E27
Ceramic Master-PLUS Metal Halide
Venture Ceramic Master-PLUS lamps use the latest in ceramic arc tube design. Our slip cast arc tube provides excellent reliability due to its factory formed construction. The single piece arc tube with contours similar to Venture Uni-form速 lamps offers better colour control, higher lumens and longer life.
33
Designer Colour® Lamps No Filters, No Gels Venture’s Designer Colour® range is unique. Now you can achieve superb primary colour generation without the need for filters or gels. No filtration is involved in the generation of colour. Instead, the metal halides in the arc tube are selected for their ability to generate individual saturated colours. Their advanced chemistry ensures excellent colour uniformity both when the lamps are new and throughout their lives.
Features
Applications
• Primary colour generation - no filtration required • Highly efficient - fewer fixtures required • Operate on standard ballasts • Compact size - good optical control
• Theme parks • Architectural lighting • Building facades
Enclosed Rated Double Ended (RSC-RX7s) Watts
Lamp Description
Product No. Colour
Oper. Pos.
Fig.
70
MH-DE 70W/UVS/BDX
00177
Blue
HOR±45°
A
Ctn Qty 25
70
MH-DE 70W/UVS/GDX
00178
Green
HOR±45°
A
25
70
MH-DE 70W/UVS/PDX
00179
Pink
HOR±45°
A
25
70
MH-DE 70W/UVS/MDX
00180
Magenta
HOR±45°
A
25
150
MH-DE 150W/UVS/BDX
33496
Blue
HOR±45°
B
25
150
MH-DE 150W/UVS/GDX
33851
Green
HOR±45°
B
25
150
MH-DE 150W/UVS/PDX
00181
Pink
HOR±45°
B
25
150
MH-DE 150W/UVS/MDX
00182
Magenta
HOR±45°
B
25
Ctn Qty
Enclosed Rated Single Ended (G12/BiPin) Watts
Lamp Description
Product No. Colour
Op.Pos.
Fig.
70
HIT 70W/G12/UVS/BDX
00183
Blue
U
C
25
70
HIT 70W/G12/UVS/GDX
00184
Green
U
C
25
70
HIT 70W/G12/UVS/PDX
00185
Pink
U
C
25
70
HIT 70W/G12/UVS/MDX
00186
Magenta
U
C
25
150
HIT 150W/G12/UVS/BDX
84684
Blue
U
C
25
150
HIT 150W/G12/UVS/GDX
26786
Green
U
C
25
150
HIT 150W/G12/UVS/PDX
00187
Pink
U
C
25
150
HIT 150W/G12/UVS/MDX
00188
Magenta
U
C
25
Ctn Qty
Enclosed Rated Single Ended (E27)
34
Watts
Lamp Description
Product No. Colour
Op.Pos.
Fig.
150
HIE 150W/U/LU/BDX
33051
Blue
U
D
12
150
HIE 150W/U/LU/GDX
33520
Green
U
D
12
150
HIE 150W/U/LU/PDX
00189
Pink
U
D
12
150
HIE 150W/U/LU/MDX
00190
Magenta
U
D
12
A MH-DE
B MH-DE
C G12
D E54
Contact to Contact = 114.2mm Base = RSC (RX75)
Contact to Contact = 132mm Base = RSC (RX75)
Dia. = 23 mm MOL = 110 mm LCL = 56 mm Base = G12
Dia. = 46 mm MOL = 211 mm LCL = 127 mm Base = EP39(POMB)
Venture
Enclosed Rated Single Ended (E40) Watts
Lamp Description
Product No. Colour
Oper. Pos.
Fig.
Ctn Qty
250
HIT 250W/U/LU/BDX
00163
Blue
U
E
12
250
HIT 250W/U/LU/GDX
00164
Green
U
E
12
250
HIT 250W/U/LU/PDX
00191
Pink
U
E
12
250
HIT 250W/U/LU/MDX
00192
Magenta
U
E
12
400
HIT 400W/U/EURO/BDX
88342
Blue
U
F
12
400
HIT 400W/U/EURO/GDX
64390
Green
U
F
12
400
HIT 400W/U/EURO/PDX
97354
Pink
U
F
12
400
HIT 400W/U/EURO/MDX
00242
Magenta
U
F
12
400
HIT 400W/U/LU/BDX
00239
Blue
U
F
12
400
HIT 400W/U/LU/GDX
00240
Green
U
F
12
400
HIT 400W/U/LU/PDX
00241
Pink
U
F
12
400
HIT 400W/U/LU/MDX
00194
Magenta
U
F
12
1000
HIT 1000W/U/LU/BDX
00195
Blue
U
G
6
1000
HIT 1000W/U/LU/GDX
00196
Green
U
G
6
Designer Colour® Lamps
Designer Colour® lamps operate on standard ballasts and allow the designer to convert any standard fixture into one rich colour. • Available in 70, 150, 250, 400 and 1000W • Choose from Green, Blue, Pink and Magenta • High efficiency - fewer fixtures required • Compact size • Good optical control
E T46 Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40
F T46 Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40
G T76 Dia. = 76 mm MOL = 340 mm LCL = 220 mm Base = E40
35
Aquatic & Special Purpose Lamps Metal Halide lamps with very high colour temperature ranging from 6.5K-10K. Suitable for a variety of special applications including aquarium lighting.
Double Ended
Enclosed Rated Watts
Lamp Description
Product No. Colour Temp
Op.Pos.
Fig.
70
MH-DE 70W/6.5K
00255
6500
HOR±45°
A
Ctn Qty 25
70
MH-DE 70W/10K
00143
10000
HOR±45°
A
25
150
MH-DE 150W/6.5K
00258
6500
HOR±45°
B
25
150
MH-DE 150W/10K
00144
10000
HOR±45°
B
25
Double Ended
Enclosed Rated Watts
Lamp Description
Product No. Colour Temp
Op.Pos.
Fig.
Ctn Qty
250
MH-DE 250W/6.5K
00261
6500
HOR±45°
C
25
250
MH-DE 250W/10K
00145
10000
HOR±45°
C
25
Tubular E27
Enclosed Rated Watts
Lamp Description
Product No. Colour Temp
Op.Pos.
Fig.
Ctn Qty
150
HIT 150W/6.5K
00264
6500
U
D
12
150
HIT 150W/10K
00265
10000
U
D
12
Tubular E40
Enclosed Rated Watts
Lamp Description
Lamp No.
Colour Temp
Op.Pos.
Fig.
Ctn Qty
250
HIT 250W/6.5K
00268
6500
U
E
12
250
HIT 250W/10K
00146
10000
U
E
12
400
HIT 400W/6.5K
00271
6500
U
E
12
400
HIT 400W/10K
00147
10000
U
F
12
400
HIT 400W/15K
00272
15000
U
F
12
400
HIT 400W/20K
00273
20000
U
F
12
Open Rated
36
Watts
Lamp Description
Product No. Colour Temp
Op.Pos.
Fig.
Ctn Qty
250
HIPT 250W/10K
00275
10000
U
G
12
400
HIPT 400W/10K
00276
10000
U
H
12
A MH-DE
B MH-DE
C MH-DE
D T38
E T15/46
F T15/46
G T52
H T52
MOL = 114.2 mm Base = RSC (R75)
MOL = 132 mm Base = RSC (R75)
MOL = 163 mm Base = Fc2
Dia. = 38 mm MOL = 156 mm LCL = 102 mm Base = E27
Dia. = 46 mm MOL = 225 mm LCL = 146 mm Base = E40
Dia. = 46 mm MOL = 285 mm LCL = 175 mm Base = E40
Dia. = 52 mm MOL = 215 mm LCL = 132 mm Base = E40
Dia. = 52 mm MOL = 225 mm LCL = 146 mm Base = E40
Venture
Aquatic & Special Purpose Lamps Lamps
37
Ventronic HID Control Gear Terminal Block Versions
Ventronic Electronic Control Gear Lamp (W)
(A)
Ballast Code
Input Voltage (V)
Circuit Watts (W)
Running Current (A)
Max Case Temp (tc)
Dimsensions (LxWxH/Fix) (mm)
Weight (kg)
Fig
Lamp Types
20 25 35 50 70 100 150
0.225 TBA 0.5 0.76 1.0 1.1 1.8
V20MSB255 V25MSB255 V35MSB255 V50MSB255 V70MSB255 V100SSB255 V150SSB255
185-254 185-254 185-254 185-254 185-254 185-254 185-254
24 29 45 56 79 110 161
0.1 0.12 0.19 0.23 0.33 0.46 0.67
80 80 80 80 80 80 80
110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 144 x 91 x 37/130-135 x 73-78 144 x 91 x 37/130-135 x 73-78
0.23 0.23 0.23 0.23 0.23 0.425 0.425
A A A A A A A
CMH, BriteSpot CMH CMH, CDM, HCI, ColorArc, BriteSpot CMH, CDM, HCI, ColorArc CMH, CDM, HCI, ColorArc CMH, CDM, HCI, SON, ColorArc CMH, CDM, HCI, SON, ColorArc
Cable Clamp Versions
Ventronic Electronic Control Gear Lamp (W) 20 25 35 50 70 100 150
(A)
Ballast Code
Input Voltage (V)
Circuit Watts (W)
Running Current (A)
Max Case Temp (tc)
Dimsensions (LxWxH/Fix) (mm)
Weight (kg)
Fig
Lamp Types
0.225 TBA 0.54 0.76 1.0
V20MSC255 V25MSC255 V35MSC255 V50MSC255 V70MSC255
185-254 185-254 185-254 185-254 185-254
24 29 45 56 79
0.1 0.12 0.19 0.23 0.33
80 80 80 80 80
110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64 110 x 76 x 32/100 x 64
0.23 0.23 0.23 0.23 0.23
B B B B B
CMH, BriteSpot CMH CMH, CDM, HCI, ColorArc CMH, CDM, HCI, ColorArc CMH, CDM, HCI, ColorArc
1.1 1.8
V100SSC255 V150SSC255
185-254 185-254
110 161
0.46 0.67
80 80
171 x 91 x 37/147 171 x 91 x 37/147
0.425 0.425
B B
CMH, CDM, HCI, SON, ColorArc CMH, CDM, HCI, SON, ColorArc
Only Ventronic offers you all of these benefits • Perfect partner for track spotlights • Ideal for use in retail, display, and commercial installations • Metal base and enclosure • Ignition voltage <2,5kV • 2.5mm2 terminal block • Fast start • Compact and light weight • Microprocessor controlled • Remote operation up to 25m • Easy fixing • Accepts 0.75mm2 to 2.5mm2 solid and stranded cable • Energy saving • Operates Ceramic Metal Halide, Quartz Metal Halide, HPS
FIG A
FIG B W
W H
H L
38
L
Venture
Ventronic HID Control Gear Lamps
39
Australia New Zealand â&#x20AC;&#x201A;40 Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 www.venturelighting.com.au www.venturelighting.co.nz +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339 www.venturelighting.com.sg www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.co.nz sales@venturelighting.com.au Email: sales@venturelighting.com.sg sales@venturelighting.com.au
Introduction Venture Lighting makes both lamps and ballasts. The company supports industry standards; however, Venture understands their limitations. Venture optimises its lamps and ballasts for peak system performance that goes beyond the standards. This is reflected in Ventureâ&#x20AC;&#x2122;s warranty policy when Venture lamps and ballasts are used together. This technical reference provides information on Venture Lightingâ&#x20AC;&#x2122;s lamps and ballasts.
Venture
About Metal Halide
Consensus standards among lamp and ballast manufacturers assure compatibility of various lighting components. Internationally, IEC codes are used. These codes assure that lamps and components from different manufacturers work together. They describe lamp dimensions as well as thermal and electrical requirements.
Characteristics The unique characteristics of metal halide lighting provide high performance such as:
Versatility Metal halide lamps are relatively unaffected by ambient temperature, equally suited for indoor or outdoor use. Extensive style and wattage options allow for many applications.
Lumens Per Watt White Light Sources Metal Halide 65-115 Fluorescent 30-98 Mercury 35-58 White HPS 40-47
Long Life Metal halide lamps have an average life of 15,000-20,000+ hours, more than ten times that of incandescent. Better Light Quality The output of metal halide lamps is closer to natural sunlight than most other light sources. People prefer white light because of better visual acuity, even at lower light levels. Designable Colour Metal halide lamps can be designed to produce almost any colour temperature desired, from 2700K to 20,000K. Speciality colours, including Blue, Green, Aqua and Pink, can also be produced. Excellent Colour Rendering Metal halide offers excellent colour rendering, with a 65-90 CRI (Colour Rendering Index). Compact Size Metal halide generates high light levels from a compact light source. This allows for smaller, more controllable luminaires.
Incandescent 15-35 0
20
40
60
80
100
120
Technical Information
High Efficiency Metal halide lamps generate 65-115 lumens per watt, more than incandescent, fluorescent or mercury vapour lamps.
Positive Environmental Impact Since metal halide lamps deliver light more efficiently than incandescent, widespread acceptance of the technology has a positive effect on air quality and the environmental waste stream. Lower electrical power generating requirements means less air pollution. Efficient long-life systems mean less landfill waste.
Five times more efficient than incandescent and a more efficient light source means less waste.
41
About Metal Halide Technology Goes Head-to-Head MH vs. Incandescent A 100 watt metal halide lamp provides five times the lumen output of a 100 watt incandescent lamp, and will last 20 times longer. Although incandescent has a low initial lamp cost, metal halide has lower total operating cost over life. MH vs. Mercury Vapour Mercury lamps have long life, but are not as energy efficient as metal halide, producing only 35-58 lumens per watt. Their limited blue-green light spectrum has a lower CRI than metal halide. MH vs. HPS While HPS lamps offer long life, they do not deliver the same light quality as metal halide. Because of their dominant sodium content, HPS lamps yield strong yellow light (2200K) and have a very poor CRI of 20-25. The full spectrum light of metal halide has a much higher CRI. MH vs. Fluorescent Fluorescent lamps are harder to direct because of their larger size. One 100 watt metal halide lamp produces the same light as three 48” high output T8 fluorescent lamps. Metal halide lamps also tolerate a wider operating temperature range. Fluorescences are often limited to temperature-controlled indoor applications. T8 fluorescent lamps perform optimally at approximately 77ºF (25ºC), degrading measurably as temperature varies. T5 lamps perform similarly, but peak at 95ºF (35ºC).
42
Australia New Zealand Singapore
Metal Halide
Sodium
Mercury
Metal halide generates light closer to sunlight than any other HID light source.
Wider Range of Applications Specifiers can now select from a broad variety of lamp types and wattages to suit almost any application. Metal halide lighting is used today indoors and out, for industrial, commercial, retail and municipal spaces. Popular for sports facilities and site lighting, it is increasingly found in supermarkets, big box retail, offices and lobbies. The Most Advanced Technology A major advancement in metal halide lighting was the introduction of Venture’s revolutionary Uni-Form® pulse start system. This second generation technology holds the future for metal halide. Uni-Form® pulse start systems offer up to 50% more lumens per system watt than do traditional metal halide lamps and ballasts. Its capabilities continue to improve. Recently, Venture became the only manufacturer to offer Uni-Form® pulse start lamps optimised for horizontal-only operation. Our high wattage e-Lamp®, designed to operate on high frequency electronic ballasts with built-in dimming down to 35% power, is another unique new high performance product. New developments will soon bring better lumen maintenance and even more wattage options for specifiers.
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 www.venturelighting.com.au www.venturelighting.co.nz +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339 www.venturelighting.com.sg www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Uni-Form® pulse start metal halide lighting systems The Uni-Form® pulse start formed-body arc tube combined with new, more efficient low current crest factor ballasts using high voltage ignitors provides higher light levels initially (20% more) and significantly more maintained light over time (40% more) than today’s standard metal halide.
More Light - A Bright Insight
System Solutions
Many of Venture’s Uni-Form® pulse start lamps can be used horizontally too giving 20% more initial lumens than standard, universal technology.
Venture’s pulse start system technology represents advancement as important as the invention of the metal halide lamp. Every change in our arc tube design, lamp construction and ballast enhances overall system performance. This metal halide focus allows us to offer a vast array of integrated packages, providing optimum lighting efficacy and quality for virtually any application.
Quality • Exclusive formed body arc tube shaped to follow the curve of the arc stream • Patented stronger weldless mount construction No welds mean less breakage during shipping
Uni-Form® pulse start lamps provide superior performance compared to traditional metal halide lamps. The specific benefits are higher efficacy, better colour uniformity, faster warm-up, improved lumen maintenance and longer life. It all takes place in Venture’s revolutionary formed-body arc tube.
Performance • Longer lamp life • Enhanced lumen maintenance • Excellent system colour uniformity • Hot restart in less than half the time of standard pinch body metal halide systems
One key to superior lamp performance is heat management. In traditional arc tubes, uneven heating prevented optimum arc enhancement. Venture created an exclusive, tipless formed-body arc tube, sculpted to follow the actual curve of the arc stream. The shape creates a more uniform temperature profile. Higher temperatures draw more halides into the stream, resulting in more light generated. Our unique sculpting process also moulds each arc tube for improved colour uniformity.
• 50% faster warm-up Safety • Shrouded open fixture protection • UV-Shield® - Blocks up to 80% UV, 50% more than most UV-reducing lamps • Reduces UV damage to merchandise and signage Selection • Venture’s Uni-Form® pulse start line of lamps has the greatest selection of lumen packages: 50W through 1000W
Technical Information
Uni-Form® Pulse Start Lamp Technology
• Tipless arc tube - Totally uniform shape further improves performance for maximum colour and light output uniformity
Venture
About Pulse Start
Faster Warm-Up/Restrike
• Most complete line of open-rated products available in the industry back to top
Our exclusive formed-body arc tube and ignitor starting provides faster initial warm-up and hot restrike in up to 60% less time.
® Uni-Form ge ta n Adva
Restrike
Warm up inutes 4 Time in m 3 2 0
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
1
Standard Power Level
Ceramic
43
About Pulse Start High Performance Results Superior Lumen Maintenance Uni-Form® pulse start system lumen output does not decay as rapidly over life as traditional metal halide. Mean lumens improve dramatically.
Uni-Form® 350 watt vs standard 400 watt lamp 44,000
Colour Uniformity Lamp-to-lamp colour variations occur due to arc tube temperature differences and poor power regulation. Venture minimizes variation through consistent thermal characteristics in every arc tube and better power control from our ballasts. Better Cold Starting Uni-Form® technology offers more reliable starting at extreme temperatures, down to -40°C (-40°F). It’s perfect for winter weather or warehouse freezer conditions.
Life in hours 5,000
10,000
15,000
20,000
Uni-Form® 400 watt vs standard 400 watt lamp
Uni-Form® MH400W/U/PS
Lumens
28,000
Uni-Form® pulse start technology will exceed your expectations. More light for less energy makes Uni-Form® pulse start the most logical lighting choice for designers and corporate energy managers seeking to drastically cut power bills. Compared to standard metal halide, Venture’s revolutionary system offers up to 50% improvement in system mean lumens per watt. In practical applications, the higher efficiency translates into a saving of more than 100 watts per luminaire! And that saving comes while still producing the same, or more, high quality light.
44
MH400W/U
20,000
36,000
The Bottom Line Is More Light For Less Energy.
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
Uni-Form® MH350W/U/PS
28,000
44,000
More Optically Precise Our patented weldless arc tube mount precisely centres the arc. It outlasts welded mounts, staying more consistently on spec.
Australia New Zealand Singapore
36,000
Lumens
Longer Life Our Uni-Form® pulse start system offers up to 50% longer lamp life along with improved lumen maintenance. This directly benefits end-users by reducing lifetime operating costs. While 50% of standard metal halide lamps survive at the end of their rated life, 70% of Uni-Form® pulse start lamps will still be operating.
MH400W/U
20,000 Life in hours 5,000
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
10,000
15,000
20,000
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Venture
Light output Open Luminaire vs Enclosed Luminaire 100 hours
Open
83.2 FC
9000 hours (60% life)
Enclosed
Enclosed
Open
80.7 FC
52.7 FC
62.4 FC
3% less light
16% less light
All ratings based on the use of a 9000 lumen rated 100 watt metal halide, vertically oriented lamp in a commercially available 8” aperture, black baffled downlight.
% Lumens
Many factors affect the performance of metal halide lamps over time. Most of these factors (see table) are controllable in the design of the lighting system. Incorporating as many of the optimised conditions as possible will deliver the best performance from any given metal halide lighting system. More light reducing conditions present in the design of the lighting system create a gap between published “optimised” ratings and actual lighting system performance.
100 90 80 70 Uni-Form® Pulse Start Lumen Maintenance 60 100 50 90 40 80 30 70 20 60 10 50 0 10 20 30 40 50 60 70 80 40 0 % Life 30 20 10 0
% Lumens
Lumen maintenance curves represent the lamp manufacturer’s estimate of the best lamp lumen output plotted over time. Typically, each group of lamps tested will display a range or scatter of lumen maintenance values at each interval measured. Therefore, individual lamps may vary from published mean lumen ratings.
Even within the Uni-Form® pulse start system, you can expect a range of lumen maintenance from 70% to 80%. (see chart below) Performance will vary depending on the number of light-reducing conditions present. By selecting a Uni-Form® pulse start lamp and optimising the system conditions, significant improvements in lighting system performance can be achieved.
0
Standard probe start lamps
Vertical operating position
Horizontal or off-vertical operating positions
Operating cycles > 10 hours
Short operating cycles <10 hours
Low current crest factor (CCF) ballasts
High CCF ballasts
Clear lamps
Coated lamps
UV-blocking lamps
Non-UV-blocking lamps
Open luminaires
Enclosed luminaires
20
30
40
50
% Life
60
70
100
80
90
100
% Lumens
Pulse start lamps
100 90 80 70 60 100 50 90 40 80 30 70 20 60 10 50 0 40 0 30 20 10 0
% Lumens
Light-Reducing
10
90
Range of Metal Halide Lumen Maintenance
System Performance Factors in Lighting Design Optimized Conditions
Technical Information
For example, Venture’s Uni-Form pulse start lamp can be expected to deliver mean lumens approaching 80%. In contrast, a traditional metal halide system operating under light-reducing conditions may deliver only 50% lumen maintenance. Venture Lighting publishes “optimised mean lumens.”
The lumen output values at specific hours of lamp life can be measured and plotted. This lumen maintenance (or lumen depreciation) curve contains important data for lighting designers. Though initial lumen ratings at 100 hours are frequently the basis for comparing light sources, mean lumens, determined at 40% of rated lamp life, are the most important. Mean lumen ratings are based on the lamps operating at 10 hours per start (except where noted). Lamp lumens are measured on a reference ballast in the designed operating position at the rated lamp wattage.
0
10
20
30
40
50
60
70
80
90
100
60
70
80
90
100
% Life
10
20
30
40
50
% Life
45
Colour The “colour” of light sources is derived from a complicated relationship derived from a number of different measurements, including Correlated Colour Temperature (CCT), Colour Rendering Index (CRI), and spectral distribution. In general, colour is most accurately described by a combination of CCT and CRI.
Colour Rendering Index (CRI or Ra) In general, CRI is a numeric indication of a lamp’s ability to render individual colours accurately relative to a standard. The CRI value is derived from a comparison of the lamp’s spectral distribution to the standard (e.g. a black body or the daytime sky) at the same colour temperature. Colour Shift and Variation Different colours are produced in metal halide lamps by using various arc tube shapes and metal halide salts. In new lamps these halides need to “burn-in” for approximately 100 hours before they reach their optimum colour. This is why new lamps can sometimes be unstable or vary in colour. As metal halide lamps age, chemical changes occur causing shifts in colour. Generally, traditional probe start lamps shift approximately twice as much in CCT over life compared to Uni-Form® pulse start lamps. Special Colours Designer Colour® lamps that produce blue, green, aqua and pink light are available for special applications where colour is needed without light loss due to filters. Different Colours Venture Lighting offers lamps in many colours to suit virtually any lighting application. Outlined below are the various colour temperatures (CCT) currently available: • 27K 2700K - Used as a replacement for very warm incandescent lamps (coated only).
Correlated Colour Temperature (CCT) The first factor in choosing a lamp colour is the Correlated Colour Temperature. For example, if a retailer wants lighting to blend in with warm halogen accent lamps, the retailer may choose a Venture® HIPE 100W/C/U/LU/UVS/3K, which has a Correlated Colour Temperature of 3200K. CCT is defined as the absolute temperature (expressed in degrees Kelvin) of a theoretical black body whose chromaticity most nearly resembles that of the light source. The CCT rating is an indication of how “warm” or “cool” the light source appears. The higher the number, the cooler the lamp colour will appear. The lower the number, the warmer the lamp colour will appear. Spectral Energy Distribution When we look at a light source, the eye “perceives” a single colour. In reality, we are seeing literally thousands of colours and hues made up of a combination of different wavelengths of light. These different combinations and the relative intensity of various wavelengths of light are used to determine the CRI of a light source.
46
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
• 3K 3000K-3200K - Used as a general warm, white light source, available in clear or coated finish for retail or interior applications; blends with halogen lamps. • 4K 3700K-4000K - Used as a neutral white light source, available in clear or coated finish for general lighting, factories, parking lots, warehouses. • 5K 5000K - A moderately high CCT daylight source used in general and retail lighting applications. • 6K 6500K - A high CCT daylight source used to simulate average outdoor light conditions. • 10K 10,000K - A very high CCT, daylight light source, used in horticulture and aquarium applications.
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Studies on nighttime visibility demonstrate experimentally that the sensitivity of the human eye to different colours of light at various light levels determines the true, or effective, lumen output of a lamp. Recent research shows that the colour output of the light source has a significant effect on nighttime visibility, which is important because road accidents occur mostly at night. Also, it is well known that the eye responds to colour depending upon the amount of light available. Photopic, Scotopic And Mesopic Conditions
Rods And Cones The change in the eye’s spectral response is due to the presence of two types of light receivers in the retina, called rods and cones. Rods are responsible for human vision at low light levels and are located in the peripheral field of view. Conversely, only objects viewed directly by the eye are seen by the cones. Rods are sensitive to scotopic light; cones react to photopic light. Therefore, as the light level is reduced, cones become less active and rods become more active.
Venture
Light Levels
Eye Colour Sensitivity And Lumens The value of a lamp’s lumen output is different when considering the shifting colour sensitivity of the eye at low light levels. The effective lumens will be different from the measured photopic lumens. As light diminishes from photopic to scotopic conditions, the effective lumens of yellow HPS light sources are reduced and the effective lumens of white light with blue/green content increases.
Lumens are the standard measure of light output, but light is actually defined as energy evaluated by the eye. Standard lumen measurements define the light output response of a person only during high light levels (called photopic light), typical of daylight and interior lighting. The light meter measures photopic light as seen by the central region of the eye. When light levels are very low, like starlight, the viewing conditions are referred to as “scotopic.” Under these conditions, the eye’s visual response changes dramatically. Sensitivity to yellow and red light is greatly reduced, while response to blue light is vastly increased. If lamp lumens under scotopic viewing conditions have been determined using photopic measurements, the lumen value does not accurately measure the true amount of light production as perceived by the human eye.
Metal Halide Lamps For Low Light Levels A typical metal halide lamp has strong light output in the blue, green and yellow areas, resulting in high lumen output at all light levels. The blue light output of metal halide is in the high sensitivity region of the eye for low light levels. This means that the effective lumens actually increase for a metal halide lamp as the light level reduces and the eye shifts to a blue/green peak sensitivity. The ability to detect fine contrast is also significantly better under metal halide sources than sodium. Reaction time under LPS and HPS lighting is roughly 50% longer than for metal halide. Therefore, the colour output of a light source has an important influence on safety. Studies have shown that metal halide lighting, in some circumstances, can be up to six times as effective as HPS. This can make a difference in peripheral viewing and dark areas where hidden hazards may be present.
Technical Information
This effect is dramatic for Low Pressure Sodium (LPS) lamps. Almost all energy output from this lighting system is yellow, resulting in high photopic lumen output. At low light levels, the effectiveness of LPS lamps is drastically reduced.
The eye response does not shift suddenly from high light levels to low light levels. A gradual change occurs as light levels are reduced in twilight and typical street lighting conditions. This is the “mesopic” condition in which the eye’s response lies somewhere between photopic and scotopic.
47
Proper Use of Metal Halide Lamps Metal Halide Compliance Venture® lamps comply with local and international standards.
It is imperative that users adhere to specified luminaire and lamp operating positions and requirements. The operation of lamps in positions other than those specified can result in severe reductions in lamp performance, including lamp life, light output and colour. Incorrect operating positions can also create the possibility of an early failure.
“WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured and the arc tube continues to operate. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” Careful adherence to the precautions mentioned above may not eliminate all possible risks associated with the use of metal halide lamps, but will reduce the likelihood of personal injury or property damage.
Correct Operation and Warnings For High Intensity Discharge Lamps High Intensity Discharge (HID) lamps require auxiliary equipment (ballasts, capacitors, ignitors or power supplies) to provide the correct electrical values for starting and operating. This auxiliary equipment must meet all electrical specifications outlined by local and regional authorities. Venture Lighting International will not be responsible for poor performance, personal injury, property damage, burns or fire from lamps operating on unapproved auxiliary equipment or from lamps being operated in a manner inconsistent with their design. Power should always be turned off and preferably locked out in accordance with local or relevant OH&S guidelines whenever installation, removal or maintenance is performed on lighting systems. Safety glasses and gloves should be used when installing or removing HID lamps. Lamps should be installed firmly into appropriate lamp sockets, without over tightening, to avoid loosening from vibration. HID lamps and their arc tubes operate at extremely high temperatures and may shatter as a result of misapplication, system failure or other factors. Scratches on the outer bulb, direct contact with water or excessive installation pressure can also cause the lamps to break. Breakage may release extremely hot glass and lamp parts into the surrounding environment and raise the risk of fire, personal injury or property damage. Injury may also be caused by ultraviolet energy from an unjacketed HID lamp. If the outer jacket should break, immediately turn the power off. Do not remove a lamp until it has completely cooled; then replace it with a new Venture® lamp. In areas susceptible to contamination by flying glass, where flammable materials are present or where there is a possibility of personal injury, users should seek additional protective measures by using open fixture lamps and enclosed luminaires.
48
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
End-of-Life and Reduction of Risk At end-of-life, the vast majority of metal halide lamps will fail simply by not reigniting. On rare occasions, metal halide lamps may fail in a violent manner. The possibility of this failure is significantly reduced by group relamping at or before the rated end of life. (see Group Relamping) In any application where lamps are operated continuously (24 hrs/day, seven days/ week), the lamps should always be turned off for a period of at least 15 minutes once a week, a precaution that can reduce the possibility of violent failures. This procedure is not required when Venture’s open rated, shrouded lamps are used. These lamps are easily identified by the “MP”, “MPI” or “HIPE” in the order code. Starting and Restarting Characteristics Probe start metal halide lamps will start at an ambient temperature of -30°C (-22°F) or higher. Full light output does not occur immediately when power is applied to any metal halide lamp; there is a time delay of at least two to four minutes after starting before lamps reach full light output. After lamps have started, a power interruption of 1/4 cycle (1/240th of a second) or more may cause the lamps to extinguish. Several minutes are required before an arc can be re-established by the ballast and full light output achieved. The exact time is dependent on a number of factors including lamp wattage, ballast and ignitor characteristics, ambient temperature, fixture dimensions and supply voltage. The time needed to establish full light output can be as short as three minutes and as long as 15 to 20 minutes. In general, pulse start technology dramatically decreases the time for hot restart. Venture’s exclusive Uni-Form® pulse start formed body arc tube provides warm-up and hot restrike in up to 60% less time and allows better starting, even down to -40°C (-40°F).
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Lamp Life
Lamp Starting
Lamp life is an important consideration when purchasing a new, retrofit or replacement lamp. Two very different and distinct terms describe life: “rated life” and “economic life.”
Pulse start metal halide ballasts provide the proper combination of open circuit voltage and high voltage pulses to start the lamp. The pulse is provided by a specially designed ignitor, or starter, that is used in conjunction with the ballast. As soon as the ignitor senses that the lamp has started, it discontinues the pulsing operation. At this point, the ballast sustaining voltage must be sufficient to maintain lamp operation. A positive feature of this system is that the lamp will hot restart in 3-4 minutes following a power interruption. Traditional probe start metal halide ballasts can take as long as 10-15 minutes to restart the lamp.
Rated Life Rated, or average (median), life for metal halide lamps is a value of lamp life expectancy based on laboratory and field tests of representative lamps, operating on approved ballasts, with a burn cycle of at least 10 hours per start. The average life is determined when 50% of traditional metal halide lamps initially installed are still operating. For 320-875 watt Uni-Form® pulse start lamps, life is determined when 70% of the initial lamps installed are still operating.
Economic Life Economic life refers to the hours of operation during which a lamp is designed to provide optimum light output and colour quality as well as lowest replacement cost. Economic life describes actual lamp life better than rated life because rated life does not account for the lumen depreciation and colour shift that occur as lamps age. The economic life of lamps is generally 60% to 75% of the lamp rated life. Though economic life is important when considering a lighting system, lamp data tables show rated life because they provide a comparison with other lamp manufacturers’ ratings.
The ballast open circuit voltage starts traditional probe start metal halide and mercury vapour lamps. Auxiliary electrodes, or probes, aid these lamps in starting. The probe electrode is disconnected after lamp has warmed up.
Technical Information
Various operating conditions affect lamp life. One key factor is operating position. Position-oriented lamps (designed to operate in one specific position) are tested and rated based on that designated position. Operating these lamps in any other positions can dramatically shorten life, reduce lumen output and cause colour shift. Lamps designated universal can be operated in any position. However, life expectancy and lumen output are sacrificed in certain positions. Published “rated life” for universal lamps is based on operation in the vertical position. “Rated life” for universal lamps operated horizontally is 75% of the published rating.
Venture
Lamp Life & Lamp Starting
49
Group Relamping 2) Aesthetic Quality: The quality of light changes over economic life, shifting 200K to 300K in colour. In the last 25% of rated life it may accelerate, shifting 500K to 600K. This causes old lamps to appear blue or pink especially when compared to new lamps. All the lamps in an area will generally change colour together; so the colour shift of the lamps will be most noticeable during spot relamping.
Group relamping offers significant savings in time and labour costs over spot replacing failed lamps. Regularly scheduled maintenance based on projected lamp life and lumen depreciation keeps a lighting system functioning at its maximum by replacing all lamps at their economic life. This provides: • Optimum light output • Superior aesthetic quality • Optimum energy efficiency • Lower labour costs 1) Optimum Light Output: Light levels are at their peak when your lighting installation is new. Most traditional metal halide lamps decrease in light output to 40% of initial light output by the end of rated life. A number of factors may accelerate this reduction in efficacy (lumens per watt). Group relamping at economic life keeps the light levels from dropping significantly. It also provides an opportunity to remove dirt accumulation in the luminaires. Cleaning during group relamping saves time and helps maintain optimum light levels. A cleaner, well-lit environment increases safety and security, can contribute to higher worker productivity and creates a better impression on visitors.
18 Month Maintenance Program Typical Lamp Lumen Performance
3) Optimum Energy Efficiency: While the light output of traditional metal halide lamps decreases over life, they still consume the same (or sometimes more) electricity. Since energy is the largest cost of lighting, group relamping prevents almost half of the energy from being wasted by under-performing lamps. For example, a 400 watt traditional metal halide lamp may consume $800 of electricity over rated life. After 60% of rated life, about $320 is wasted on lamps providing less than mean lumens. Spot relamping wastes energy dollars. The cost of a new lamp and the labour to install it as part of group relamping is generally less than 5% of the total energy cost. 4) Cost Effective Replacement: Group relamping, as a planned maintenance program, reduces downtime and labour costs. Spot relamping often takes an employee away from regular duties just to replace a burned out lamp. This inconvenience grows as lamp failures increase towards the end of rated life. Group relamping not only eliminates wasted labour and workday disruptions, it allows for scheduling during normal shutdown periods. Group relamping at economic life is a practical way to reduce energy and maintenance costs, as well as sustain workers’ visual acuity with a bright workplace environment. It also offers the opportunity to replace older lighting with Venture’s energy saving and more efficient Uni-Form® pulse start systems.
Lamp Mortality & Maintenance Curves 20 Month Maintenance Program Typical Lamp Lumen Performance
50
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Venture’s open fixture rated MP, MPI and HIPE lamps contain protective quartz shrouds which helps contain hot particles in the lamp within the event of an arc tube rupture. Open fixture rated metal halide lamps offer significant advantages for end-users, including:
Venture
Open Fixture Protection
• Do not require a luminaire lens, delivering more light • Continuous operation - 24/7/365 - No shut-off required • Block nearly all damaging UV output with UV-Shield® technology • Can be used in open or enclosed luminaires • Arc tube surrounded by a shroud • Lower luminaire costs • Easier lamp replacement • Recommended by the insurance industry
Laboratory tests demonstrate that the UV-Shield® feature extends the life of a polycarbonate luminaire lens from six to ten times longer than a standard metal halide lamp. To realize these multiple benefits, specify Venture MP, MPI or HIPE lamps for your installation. Venture Lighting is an industry leader and carries a complete line of open rated lamps, the most available in the industry.
Technical Information
UV-Shield® Technology As an added benefit, most Venture lamps feature UV-Shield® . These lamps contain specially-treated quartz shrouds that reduce ultraviolet light output by up to 80% more than regular metal halide lamps; that’s nearly all UV output. UV light emissions cause fading and damage to plastics and fabrics. UV-Shield® lamps reduce “yellowing” of polycarbonate luminaire lenses to ensure extended maximum light output while providing superior white light.
Ruptured arc tube contained within the intact outer jacket of a Venture MP open rated lamp
Open Fixture Lamp Leader Venture began producing metal halide lamps that contain a protective shroud in 1989. Venture is ahead of the game and is building lighting systems with safety in mind; your safety
51
Description Codes & Ordering Information Metal Halide Lamp Description Code Your lamp has an imprinted code that identifies the important features you need to select a replacement. A complete explanation appears below.
Lamp Type: 150 watt White-Lux® Plus pulse start lamp, open luminaire rated, universal burning, coated, reduced outer jacket with UV-Shield® protection
HIPE
150W
C
U
LU
E90
UVS
4K
Metal halide type
Lamp wattage
Outer jacket finish
Operating position
White-Lux® Plus Lamp
Bulb shape & diameter if non-standard
UV-Shield® lamp
Colour temperature family
Position of Operation
Colour Temperature and CRI
BU
Lamps designed for base up ( ±15°) operating position
27K
2700K - 2800K correlated colour temperature (nominal)
H75
Lamps designed for horizontal operation ( ±75°,from horizontal ), without the need of a position orientated base socket
3K
3000K - 3200K correlated colour temperature (nominal)
4K
3700K - 4000K correlated colour temperature (nominal)
Lamps designed for horizontal to base up operating position(or base up ±90°, except 1500W which is base up ±105°)
5K
5000K correlated colour temperature (nominal)
Horizontal high-performance standard probe start designed for horizontal ±45 operation, uses POM base
6K
6500K correlated colour temperature (nominal)
10K
10,000K correlated colour temperature
Universal operating position
732
3200K colour, 70 CRI lamps
Lamps designed for a vertical ( ±15°) operating position
734
3400K colour, 68 CRI lamps
737
3700K colour, 70 CRI lamps
740
4000K colour, 68 CRI lamps
830
3000K colour, 80 CRI lamps
850
5000K colour, 80 CRI lamps
942
4200K colour, 90 CRI lamps
950
Natural White® lamp, 5000K colour, high CRI (90+) lamps
HBU HOR U V
52
Lamp Description Example: HIPE 150W/C/U/LU/E90/UVS/4K
Australia New Zealand Singapore
+(61) 3 9800 5600 Fax +(61) 3 9800 5533 +(64) 7579 0163 Fax +(64) 7579 0164 +(65) 6844 2338 Fax +(65) 6844 2339
www.venturelighting.com.au www.venturelighting.co.nz www.venturelighting.com.sg
Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au Email: sales@venturelighting.com.au
Bulb shape (elliptical) and diameter in millimetres
ED##
Bulb shape and diameter in 1/8 in (i.e. diameter of ED28 is 3.5 in.)
EURO
Lamps designed to run on mercury reactor ballast with low pulse ignitors, usually in Europe. Euro lamps can also operate pulse ignitors, usually in Europe.
HIE
HIE E27 or E40 European-based elliptical bulb, enclosed luminaire required
HIPE
HIPE E27 or E40 European-based elliptical bulb, protected arc tube for open luminaire operation
HIT
HIT E40 European-based tubular bulb, protected arc tube for enclosed luminaire operation
HO
HO High Output
K##
Spade connectors and the width of the fly-lead wire in millimetres
LU
White-Lux® metal halide lamp designed for use with HPS control gear
MBIL
MBIL High wattage, double ended lamp
MED
Medium Base
MH
MH E26 or E39 North American-based metal halide elliptical bulb, enclosed luminaire required
MH-DE
MH-DE Double-ended metal halide lamp
MH-TS
MH-TS Double-ended metal halide lamp with a fly-wire contact
MP
Uni-Form® lamps with a protected (shrouded) arc tube designed for open luminaires
MPI
Lamps with a protected (shrouded) arc tube designed to replace standard (probe start) lamps in open luminaries
MS
High output MH lamps for dedicated operating positions
PS
Uni-Form® pulse start lamp featuring Venture’s exclusive formed body arc tube designed to follow the curve of the arc stream
T##
Bulb shape (tubular) and diameter in millimetres
UVS
UV-Shield® lamps with reduced ultraviolet output
WLC
White-Lux® City metal halide lamp featuring UV-Shield® tubular lamps designed for horizontal operation and for use with HPS Gear
CMPLUS
Ceramic Metal Halide
TC
Ceramic lamps with G8.5 base
TC
Ceramic lamps with G12 base
TD
Double Ended Ceramic lamps
TT
Tubular Ceramic lamps
ED
Eliptical Ceramic lamps
Description Codes & Ordering Information
Lamps with a coated (diffuse) outer jacket
E##
Venture
Lamp Description Codes C
For a complete product listings and the most current up-to-date information, visit us online.
53
Glossary Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and generates light
Efficacy (Lamp): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)
Auxiliary Light: Back-up light source to the HID light; typically a quartz halogen type
Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by Venture’s quartz sculpting process; has 2/3 less quartz mass than standard arc tubes for equivalent lumens; has no starter electrode
Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation for a HID ballast operating at a given supply voltage Ballast Characteristic Curve: The curve of lamp wattage vs. lamp voltage over a range of normal lamp voltages, when a HID ballast operates at a given supply voltage BTL: The distance from ballast-to-lamp Ballast Power Factor: Power consumed by the lamp and ballast (watts) divided by the product of line voltage and line current (“volt-amps” or “VA”); a measure of power quality and of concern to utilities Burning Position: The position in which lamps are designed to operate Cold Start Time: The amount of time from the application of ballast voltage to ignition Color Rendering Index (CRI or Ra): A measure of a light source’s ability to render colours relative to a standard of 100 Constant Wattage Autotransformer (CWA) Ballast: A magnetic autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp current nearly constant Correlated Colour Temperature (CCT): The perceived “colour” of the light emitted by a lamp expressed in Kelvin (K units) Current Crest Factor: The ratio of the peak to the rms value of lamp current; metal halide values range from 1.5 to 1.8 e-Lamp®: Venture’s 4000K colour temperature pulse start lamps specifically designed for use on high frequency electronic ballasts; capable of dimming down to 35% lamp power Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life)
54
Lumens: A measurement of light output; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum Lumen Maintenance: The lumen output provided by a lamp at a given point in or percentage of its life
HID: High Intensity Discharge lamps; includes metal halide, mercury vapour and high pressure sodium
Lumens Per Watt (LPW): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)
Hot Restart or Restrike Time: The amount of time from return of power after an interruption to the point of lamp ignition
Luminaire Requirements: The type of luminaire a lamp requires; i.e. enclosed or open rated
Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp
Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base
Ignitor CWA Control Gear: CWA control gear using an ignitor to start the lamp Initial Lumens: The light output of a lamp, based on photometry results, at rated wattage after 100 hours of operation Input Voltage at Lamp Dropout (Extinction Voltage): The rms value of supply voltage at which a reference lamp extinguishes when the supply voltage is uniformly reduced from rated value at 2% to 3% of rated voltage per second Input Power: See System Power Input Watts: The power measured on the input terminals of a ballast which is operating a reference lamp Lag Ballast: A magnetic ballast having a lagging lamp current with respect to the supply voltage. Current limiting is primarily inductive; holds lamp power reasonably constant with respect to lamp voltage variations Lamp Power Factor: Power consumed by the lamp divided by the product of RMS lamp voltage and RMS lamp current; it is less than unity on magnetic ballasts operating at 50 or 60hz Lamp Voltage: The voltage at which lamps operate when they are fully warmed up Lamp Wattage: The power consumed by a lamp after warm-up Light Centre Length (LCL): The distance from the centre of the arc discharge to the end contact of the base
Mean Lumens: Light output at 40% of rated lamp life Natural White®: Venture’s line of pulse start lamps that have 5000K colour temperature, 90+ CRI and 90% lumen maintenance Occupancy Sensor: Control device that dims or turns lights off after the space becomes unoccupied; may be ultrasonic or infrared-actuated Open Circuit Current (Line): The RMS current measured through the input terminals of a ballast with lamp removed or inoperative Open Circuit Voltage, Ballast (OCV): The voltage across the output terminals of a ballast when no load is connected (RMS, unless otherwise stated) Open Rated Lamp (E27): Designed for open luminaires; has a narrower neck than standard E27 base lamps. Lamp arc tube is surrounded by a protective quartz shroud Open Rated Lamp (E39 & E40): Designed for open luminaires. Lamp arc tube is surrounded by a protective quartz shroud Operating Current (Line): The power factor corrected current measured through the input terminals of a ballast which is operating a reference lamp Operating Voltage: The voltage at which lamps operate when they are fully warmed up Peak Lead Ballast: A ballast that produces a highly peaked open circuit voltage wave shape and has a capacitor in series with the lamp
Scotopic Light: Applicable during dark nighttime lighting conditions; describes lumen values measured using the low luminance eye sensitivity function centred at 507 nm (blue-green)
Position Oriented Mogul Base (POMB, EP39, EP40): Used with horizontal burning lamps; has an aligning pin embedded in the base for proper lamp orientation when it is screwed into its socket; should only be used in yellow POMB sockets with a slot in the screw shell to accommodate the aligning pin
Short-Circuit Current (Ballast): The current at the output terminals of a ballast when the output is shorted (RMS, unless otherwise stated)
Power Factor (Ballast): The quotient of the ballast input power divided by the product of the rms ballast supply voltage and ballast supply current
Pulse Start Lamp: Specially designed metal halide lamp that requires a high voltage pulse for starting; has no starter electrode (probe) and has high starting gas pressure Rated Life: The number of operating hours at which 50% of most metal halide lamps, or 70% to 80% for some Uni-Form® pulse start lamps, initially installed will still be operating Rated Supply Voltage: The voltage for which a ballast or transformer is designed and for which operation and performance characteristics are referred Reactor Ballast (Lag Ballast): An inductive component connected in series with an HID lamp to limit the current; uses a coil of wire wound around an iron core connected in series with the lamp Regulation: The percent change in lamp watts as the line voltage is changed over the designated voltage range of the ballast Restrike: To re-ignite the arc of a HID lamp Restrike Control (Hot/Cold Start): A control device that powers an auxiliary lamp in an HID luminaire after a momentary power interruption and when the HID lamp is first turned on RMS: root-mean-square S/P Ratio: The ratio of photopic lumens to scotopic lumens
Shroud: A quartz cylinder surrounding the arc tube to protect against hot arc tube particles breaking the glass bulb if an arc tube rupture occurs: reduces the risk when using metal halide lamps in open luminaries Spectral Power Distribution: The distribution of radiant power (watts) of a lamp as a function of wavelength (nm) Starter: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp Starting Current (Line): The RMS current measured through the input terminals of the ballast five to 15 seconds after the lamp has started
Glossary
Probe Start Lamp: A metal halide lamp which uses a starter electrode (probe) to assist in starting without the use of an ignitor pulse; also contains a bimetal switch and resistor
Venture
Photopic Light: Applicable during normal daytime lighting conditions; describes lumen values measured using the high luminance eye sensitivity function centred at 555 nm (yellow-green)
Starting Pulse: A high-voltage, low-energy pulse superimposed on the open circuit voltage of some HID ballasts to aid in starting a lamp Sustaining Voltage: The instantaneous voltage available to the lamp from the ballast at the time the lamp current passes through zero System Watts: The power measured on the input terminals of a ballast which is operating a reference lamp Tipless Arc Tube: An arc tube made without an auxiliary exhaust tube for dosing gases and other ingredients Uni-Form®: Venture’s pulse start lamp and ballast systems that contain a formed body arc tube; requires a high voltage pulse for starting; has improved lumen maintenance Warm-Up Time: The amount of time from ignition of the lamp to 90% light output Watts: A measure of energy (in joules) being used or emitted each second White-Lux®: Venture’s line of retrofit metal halide lamps that operate on high pressure sodium ballasts
55
Index by Wattage Wattage 20 20 20 20 20 20 25 25 35 35 35 35 35 35 50 50 50 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 150 150 150 150 150 150 150 150 150 150 150 150 150
56
Description
Part No.
Category
CM-PLUS T 20W/U/UVS/G12/830 CM-PLUS T 20W/U/UVS/G12/942 CM-PLUS TC 20W/U/UVS/G8.5/830 CM-PLUS TC 20W/U/UVS/G8.5/942 V20MSB255 V20MSC255 V25MSB255 V25MSC255 CM-PLUS T 35W/U/UVS/G12/830 CM-PLUS T 35W/U/UVS/G12/942 CM-PLUS TC 35W/U/UVS/G8.5/942 CM-PLUS TC 35W/U/UVS/G8.5/830 V35MSB255 V35MSC255 HIE 50W/U/LU/4K V50MSB255 V50MSC255 CM-PLUS ED 70W/U/UVS/830 CM-PLUS ED 70W/U/UVS/942 CM-PLUS T 70W/U/UVS/G12/830 CM-PLUS T 70W/U/UVS/G12/942 CM-PLUS TC 70W/U/UVS/G8.5/830 CM-PLUS TC 70W/U/UVS/G8.5/942 CM-PLUS TD 70W/U/UVS/RX7s/830 CM-PLUS TD 70W/U/UVS/RX7s/942 CM-PLUS TT 70W/U/UVS/830 CM-PLUS TT 70W/U/UVS/942 HIE 70W/C/U/LU/3K HIE 70W/C/U/LU/4K HIE 70W/U/LU/3K HIE 70W/U/LU/4K HIPE 70W/C/U/LU/UVS/3K HIPE 70W/C/U/LU/UVS/4K HIPE 70W/C/V/LU/UVS/27K HIPE 70W/U/LU/UVS/4K HIT 70W/G12/UVS/3K HIT 70W/G12/UVS/4K HIT 70W/G12/UVS/BDX HIT 70W/G12/UVS/GDX HIT 70W/G12/UVS/MDX HIT 70W/G12/UVS/PDX HIT 70W/U/LU/4K MH-DE 70W/10K MH-DE 70W/15K MH-DE 70W/20K MH-DE 70W/6.5K MH-DE 70W/UVS/3K MH-DE 70W/UVS/4K MH-DE 70W/UVS/BDX MH-DE 70W/UVS/FS/6K MH-DE 70W/UVS/GDX MH-DE 70W/UVS/MDX MH-DE 70W/UVS/PDX V70MSB255 V70MSC255 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/942 CM-PLUS T 100W/U/UVS/G12/830 CM-PLUS T 100W/U/UVS/G12/942 CM-PLUS TT 100W/U/UVS/830 CM-PLUS TT 100W/U/UVS/942 HIE 100W/C/U/LU/3K HIE 100W/C/U/LU/4K HIE 100W/U/LU/3K HIE 100W/U/LU/4K HIPE 100W/C/U/LU/UVS/3K HIPE 100W/C/U/LU/UVS/4K HIPE 100W/C/V/LU/UVS/27K HIPE 100W/U/LU/E90/UVS/4K HIPE 100W/U/LU/UVS/3K HIPE 100W/U/LU/UVS/4K HIT 100W/U/LU/T38/4K HIT 100W/U/LU/T46/4K V100SSB255 V100SSC255 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/942 CM-PLUS T 150W/U/UVS/G12/830 CM-PLUS T 150W/U/UVS/G12/942 CM-PLUS TD 150W/U/UVS/RX7s/830 CM-PLUS TD 150W/U/UVS/RX7s/942 CM-PLUS TT 150W/U/UVS/830 CM-PLUS TT 150W/U/UVS/942 HIE 150W/C/U/LU/3K HIE 150W/C/U/LU/4K HIE 150W/U/LU/4K HIE 150W/U/LU/BDX HIE 150W/U/LU/GDX
00360 00361 00354 00355 V20MSB255 V20MSC255 V25MSB255 V25MSC255 00362 00363 00357 00356 V35MSB255 V35MSC255 67331 V50MSB255 V50MSC255 00380 00381 00364 00365 00358 00359 00370 00371 00374 00375 96720 63173 23660 27373 52910 10003 48692 10002 12108 52983 00183 00184 00186 00185 13742 00143 00256 00257 00255 16786 60248 00177 79470 00178 00180 00179 V70MSB255 V70MSC255 00382 00383 00366 00367 00376 00377 45157 19031 79457 50340 65850 10005 39468 10050 82539 10004 76738 87368 V100SSB255 V100SSC255 00384 00385 00368 00369 00372 00373 00378 00379 69876 40563 30544 33051 33520
Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ventronic Electronic Control Gear Ventronic Electronic Control Gear White-Lux® Plus Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus G12 G12 Designer Colour® Designer Colour® Designer Colour® Designer Colour® White-Lux® Plus Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Designer Colour® Double Ended Designer Colour® Designer Colour® Designer Colour® Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus Designer Colour® Designer Colour®
Page
Wattage
30 30 30 30 36 36 36 36 30 30 30 30 36 36 14 36 36 31 31 30 30 30 30 30 30 31 31 14 14 14 14 14 14 14 14 28 28 32 32 32 32 15 34 34 34 34 28 28 32 28 32 32 32 36 36 31 31 30 30 31 31 14 14 14 14 14 14 14 14 14 14 15 15 36 36 31 31 30 30 30 30 31 31 14 14 14 32 32
150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 175 175 175 175 175 175 175 175 175 175 175 175 175 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250
Description
Part No.
Category
HIE 150W/U/LU/MDX HIE 150W/U/LU/PDX HIPE 150W/C/U/LU/E90/UVS/4K HIPE 150W/C/U/LU/UVS/3K HIPE 150W/C/U/LU/UVS/4K HIPE 150W/C/V/LU/UVS/27K HIPE 150W/U/LU/E90/UVS/4K HIPE 150W/U/LU/UVS/3K HIPE 150W/U/LU/UVS/4K HIT 150W/10K HIT 150W/15K HIT 150W/20K HIT 150W/6.5K HIT 150W/G12/UVS/3K HIT 150W/G12/UVS/4K HIT 150W/G12/UVS/BDX HIT 150W/G12/UVS/GDX HIT 150W/G12/UVS/MDX HIT 150W/G12/UVS/PDX HIT 150W/U/LU/T38/4K HIT 150W/U/LU/T46/4K MH 150W/C/U/ED28/PS/737 MH 150W/U/ED28/PS/740 MH-DE 150W/10K MH-DE 150W/15K MH-DE 150W/20K MH-DE 150W/6.5K MH-DE 150W/UVS/3K MH-DE 150W/UVS/4K MH-DE 150W/UVS/BDX MH-DE 150W/UVS/FS/6K MH-DE 150W/UVS/GDX MH-DE 150W/UVS/MDX MH-DE 150W/UVS/PDX MP 150W/C/U/ED28/UVS/PS/737 MP 150W/U/ED28/UVS/PS/740 V150SSB255 V150SSC255 HIE 175W/C/U/E54/EURO/4K HIE 175W/C/U/EURO/4K HIE 175W/U/E54/EURO/4K HIE 175W/U/EURO/4K MH 175W/C/U MH 175W/C/U/MED MH 175W/U MH 175W/U/MED MPI 175W/BU MPI 175W/C/BU MS 175W/BU MS 175W/BU/MED MS 175W/HOR HIPT 200W/H75/UVS/T52/PS/4K MP 200W/C/V/UVS/PS/732 MP 200W/C/V/UVS/PS/737 MP 200W/V/UVS/PS/740 MS 200W/BU/MED/PS/740 MS 200W/C/BU/MED/PS/737 MS 200W/C/V/PS/737 MS 200W/H75/T15/PS/740 MS 200W/V/PS/740 HIE 250W/BU/EURO/4K HIE 250W/C/BU/EURO/4K HIE 250W/C/H75/LU/4K HIE 250W/C/U/EURO/4K HIE 250W/C/U/EURO/4K HIE 250W/C/V/LU/4K HIE 250W/U/EURO/4K HIE 250W/U/EURO/4K HIE 250W/V/LU/4K HIPE 250W/C/H75/LU/UVS/4K HIPE 250W/C/HBU/LU/UVS/4K HIPE 250W/HBU/LU/UVS/4K HIPT 250W/10K HIPT 250W/H75/UVS/T52/PS/4K HIT 250W/10K HIT 250W/15K HIT 250W/20K HIT 250W/6.5K HIT 250W/H75/LU/4K HIT 250W/H75/WLC/UVS/35K HIT 250W/HOR/EURO/4K HIT 250W/U/EURO/4K HIT 250W/U/EURO/5K HIT 250W/U/LU/4K HIT 250W/U/LU/5K HIT 250W/U/LU/BDX HIT 250W/U/LU/GDX HIT 250W/U/LU/MDX
00190 00189 10082 22833 10007 41700 10051 22822 10006 00265 00266 00267 00264 12106 25779 84684 26786 00188 00187 62272 71144 21344 13556 00144 00259 00260 00258 11295 74756 33496 29963 33851 00182 00181 32147 58963 V150SSB255 V150SSC255 24729 40698 84971 36279 96627 63187 88791 15556 32519 32520 55087 70310 57330 00247 44872 59174 22147 60811 60812 70345 70764 57739 81203 81202 43634 21303 21303 56266 88246 88246 31668 29486 10076 10016 00275 00245 00146 00269 00270 00268 27965 63736 57712 33950 00033 48768 10855 00163 00164 00192
Designer Colour® Designer Colour® White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose G12 G12 Designer Colour® Designer Colour® Designer Colour® Designer Colour® White-Lux® Plus White-Lux® Plus Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Designer Colour® Double Ended Designer Colour® Designer Colour® Designer Colour® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Ventronic Electronic Control Gear Ventronic Electronic Control Gear Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Open rated Horizontal lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Euro Metal Halide Euro Metal Halide White-Lux® Plus Euro Metal Halide Standard Metal Halide White-Lux® Plus Euro Metal Halide Standard Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus Aquatic & Special Purpose Open rated Horizontal lamps Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose White-Lux® Plus White-Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide White-Lux® Plus White-Lux® Plus Designer Colour® Designer Colour® Designer Colour®
Page 32 32 14 14 14 14 14 14 14 34 34 34 34 28 28 32 32 32 32 15 15 16 16 34 34 34 34 28 28 32 28 32 32 32 18 18 36 36 22 22 22 22 24 24 24 24 25 25 24 24 24 13 18 18 18 16 16 16 16 16 22 22 15 22 25 15 22 25 15 15 15 15 34 13 34 34 34 34 15 15 22 22 22 15 15 33 33 33
Wattage
Part No.
Category
HIT 250W/U/LU/PDX MH 250W/C/U MH 250W/U MH 250W/U/5K MH 250W/U/T15 MH-DE 250W/10K MH-DE 250W/15K MH-DE 250W/3K/Fc2 MH-DE 250W/4K/Fc2 MH-DE 250W/6.5K MP 250W/BU/UVS/PS/740 MP 250W/BU/UVS/PS/EM/950 MP 250W/C/BU/UVS/PS/737 MP 250W/C/BU/UVS/PS/EM/950 MP 250W/H75/UVS/PS/740 MP 250W/H75/UVS/PS/740 MPI 250W/BU MPI 250W/C/BU MS 250W/BU MS 250W/C/BU/3K MS 250W/C/V/PS/737 MS 250W/H75/PS/740 MS 250W/H75/T15/PS/740 MS 250W/HOR MS 250W/HOR/T15 MS 250W/HOR/T15/3K MS 250W/V/PS/740 MP 320W/BU/ED28/UVS/PS/740 MP 320W/BU/ED28/UVS/PS/EM/950 MP 320W/BU/ED37/UVS/PS/740 MP 320W/BU/ED37/UVS/PS/EM/950 MP 320W/C/BU/ED28/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/732 MP 320W/C/BU/ED37/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/EM/950 MP 320W/H75/T15/L//UVS/PS/EM/950 MP 320W/H75/T15/S//UVS/PS/EM/950 MS 320W/C/H75/ED28/PS/737 MS 320W/C/V/ED28/PS/737 MS 320W/C/V/ED37/PS/737 MS 320W/H75/ED28/PS/740 MS 320W/H75/T15/L/PS/740 MS 320W/H75/T15/S/PS/740 MS 320W/V/ED28/PS/740 MS 320W/V/ED37/PS/740 HIPT 350W/H75/UVS/T52/PS/4K MP 350W/BU/ED28/UVS/PS/EM/950 MP 350W/BU/UVS/PS/950 MP 350W/C/BU/UVS/PS/EM/950 MP 350W/C/V/ED28/UVS/PS/737 MP 350W/C/V/MD/UVS/PS MP 350W/C/V/UVS/PS/732 MP 350W/C/V/UVS/PS/737 MP 350W/H75/UVS/PS/740 MP 350W/H75/UVS/PS/740 MP 350W/V/ED28/UVS/PS/740 MP 350W/V/UVS/PS/740 MS 350W/C/H75/PS/737 MS 350W/C/V/PS/737 MS 350W/H75/ED28/PS/740 MS 350W/H75/T15/PS/740 MS 350W/V/ED28/PS/740 MS 350W/V/PS/740 HIE 400W/BU/EURO/4K HIE 400W/C/BU/EURO/4K HIE 400W/C/H75/LU/4K HIE 400W/C/HOR/EURO/4K HIE 400W/C/U/E90/EURO/4K* HIE 400W/C/U/EURO/4K HIE 400W/C/U/EURO/4K HIE 400W/C/V/LU/4K HIE 400W/U/EURO/4K HIE 400W/U/EURO/4K HIE 400W/V/LU/4K HIPE 400W/BU/EURO/4K HIPE 400W/C/BU/EURO/4K HIPE 400W/C/H75/LU/UVS/4K HIPE 400W/C/V/LU/UVS/4K HIPE 400W/C/V/LU/UVS/HO/4K HIPE 400W/V/LU/UVS/4K HIPE 400W/V/LU/UVS/HO/4K HIPT 400W/10K HIPT 400W/H75/UVS/T52/PS/4K HIT 400W/10K HIT 400W/15K HIT 400W/20K HIT 400W/6.5K HIT 400W/H75/LU/4K
00191 61290 63052 27252 33479 00145 00262 84727 72748 00261 64658 19523 32658 19525 49822 49822 60722 60723 36297 18477 81365 81054 57625 94883 88353 54843 49621 10103 98530 21714 98520 10104 66506 32795 95123 95321 95320 12758 77594 67712 47549 79710 57626 59194 52236 00248 33149 51628 38197 55401 72843 27845 44097 65218 65218 47887 22149 64866 71329 46959 93749 52980 98389 33544 31545 68110 63958 58122 88787 88787 54695 20137 20137 60112 99441 94102 40511 10043 42068 10077 54918 00276 00246 00147 00272 00273 00271 43898
Designer Colour® Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Aquatic & Special Purpose Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Natural White® Open rated Horizontal lamps Uni-Form® Pulse Start - Open Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Natural White® Natural White® Natural White® Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Open rated Horizontal lamps Natural White® Natural White® Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Open rated Horizontal lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Euro Metal Halide Euro Metal Halide White-Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide Standard Metal Halide White-Lux® Plus Euro Metal Halide Standard Metal Halide White-Lux® Plus Euro Metal Halide Euro Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus Aquatic & Special Purpose Open rated Horizontal lamps Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose White-Lux® Plus
Page
Wattage
33 24 24 24 24 34 34 28 28 34 18 20 18 20 18 13 25 25 24 24 16 16 16 24 24 24 16 18 20 18 20 18 18 18 20 20 20 16 16 16 16 16 16 16 16 13 20 20 20 18 18 18 18 13 18 18 18 17 17 17 17 17 17 23 23 15 23 23 23 25 15 23 25 15 23 23 15 15 15 15 15 34 13 34 34 34 34 15
400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 450 450 450 450 600 875 875 875 875 875 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1650 2000 2000 2000 2000
Description
Part No.
Category
HIT 400W/H75/WLC/UVS/35K HIT 400W/HOR/EURO/4K HIT 400W/U/EURO/4K HIT 400W/U/EURO/5K HIT 400W/U/EURO/BDX HIT 400W/U/EURO/GDX HIT 400W/U/EURO/MDX HIT 400W/U/EURO/PDX HIT 400W/U/LU/4K HIT 400W/U/LU/5K HIT 400W/U/LU/BDX HIT 400W/U/LU/GDX HIT 400W/U/LU/MDX HIT 400W/U/LU/PDX MH 400W/C/U MH 400W/C/U/ED28 MH 400W/U MH 400W/U/5K MH 400W/U/ED28 MH 400W/U/T15 MP 400W/BU/ED28/UVS/PS/EM/950 MP 400W/BU/UVS/PS/EM/950 MP 400W/C/BU/UVS/PS/EM/950 MP 400W/C/V/ED28/UVS/PS/737 MP 400W/C/V/MD/UVS/PS MP 400W/C/V/UVS/PS/737 MP 400W/H75/UVS/PS/740 MP 400W/H75/UVS/PS/740 MP 400W/V/ED28/UVS/PS/740 MP 400W/V/UVS/PS/740 MPI 400W/BU MPI 400W/C/BU MS 400W/BU/ED28 MS 400W/C/H75/ED28/PS/737 MS 400W/C/HOR MS 400W/C/HOR/ED28 MS 400W/C/V/ED28/PS/737 MS 400W/C/V/PS/737 MS 400W/H75/ED28/PS/740 MS 400W/H75/PS/740 MS 400W/HOR MS 400W/HOR/ED28 MS 400W/HOR/T15 MS 400W/HOR/T15/3K MS 400W/V/ED28/PS/740 MS 400W/V/PS/740 MP 450W/BU/UVS/PS/740 MP 450W/C/BU/UVS/PS/737 MS 450W/C/V/PS/737 MS 450W/V/PS/740 HIT 600W/U/LU/4K MP 875W/BU/BT37/PS/740 MP 875W/C/BU/BT37/PS/737 MS 875W/BD/BT37/PS/740 MS 875W/BU/BT37/PS/740 MS 875W/HOR/BT37/PS/740 HIE 1000W/V/LU/BT120/4K HIT 1000W/HOR/4.5K HIT 1000W/U/LU/4K HIT 1000W/U/LU/5K HIT 1000W/U/LU/BDX HIT 1000W/U/LU/GDX HIT1000W/U/EURO/4K HIT1000W/U/EURO/5K MBIL S 1000W MH 1000W/C/U MH 1000W/U MH 1000W/U/5K MH 1000W/U/BT37 MS 1000W/BU MS 1000W/BU/BT37 MS 1000W/BU/BT37/PS/740 MS 1000W/BU/T25 MS 1000W/HOR/BT37/3K MS 1000W/HOR/SPORT 60 MS 1000W/HOR/T25/PS/734 MBIL S 1500W MH 1500W/HBU MH 1500W/U/XL MH-DE 1500W/T7/4K MS 1500W/HOR/XP/SPORT60 MS 1650W/HOR/XP/SPORT60 HIT 2000W/U/230V/45K HIT 2000W/U/4K MBIL S 2000W MH-TS 2000W/L/K12/4K
97731 88410 25830 00034 88342 64390 00242 97354 98748 21044 00239 00240 00194 00241 83545 20753 18520 36813 57540 55422 72315 57129 89410 88648 84629 45541 17611 17611 12445 71642 95527 26091 40013 55459 64648 24573 46416 42401 40124 58788 40509 21929 55100 32225 85260 73531 65072 59216 10138 10079 54631 58953 41686 35426 22619 33759 00154 00336 83265 00083 00195 00196 00008 00282 22417 88460 72051 35914 15332 89113 13090 71722 78952 53702 47503 49111 22151 18360 12342 46745 82070 16419 00067 00066 22132 84203
White-Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide Designer Colour® Designer Colour® Designer Colour® Designer Colour® White-Lux® Plus White-Lux® Plus Designer Colour® Designer Colour® Designer Colour® Designer Colour® Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Natural White® Natural White® Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Open rated Horizontal lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed White-Lux® Plus Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed White-Lux® Plus Euro Metal Halide White-Lux® Plus White-Lux® Plus Designer Colour® Designer Colour® Euro Metal Halide Euro Metal Halide High Wattage Lamps Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed High Wattage Lamps Standard Metal Halide Standard Metal Halide High Wattage Lamps Standard Metal Halide Standard Metal Halide Euro Metal Halide Euro Metal Halide High Wattage Lamps High Wattage Lamps
Page 15 23 23 23 33 33 33 33 15 15 33 33 33 33 24 24 24 24 24 24 20 20 20 19 19 19 19 13 19 19 25 25 24 17 24 24 17 17 17 17 24 24 24 24 17 17 19 19 17 17 15 19 19 17 17 17 15 23 15 15 33 33 23 23 27 25 25 25 25 25 25 17 25 25 25 17 27 25 25 27 25 25 23 23 27 27
Index by Wattage
Description
Venture
250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400
57
Index by Part Number
58
Part No.
Description
00008 00033 00034 00066 00067 00083 00143 00144 00145 00146 00147 00154 00163 00164 00177 00178 00179 00180 00181 00182 00183 00184 00185 00186 00187 00188 00189 00190 00191 00192 00194 00195 00196 00239 00240 00241 00242 00245 00246 00247 00248 00255 00256 00257 00258 00259 00260 00261 00262 00264 00265 00266 00267 00268 00269 00270 00271 00272 00273 00275 00276 00282 00336 00354 00355 00356 00357 00358 00359 00360 00361 00362 00363 00364 00365 00366 00367 00368 00369 00370 00371 00372 00373 00374 00375 00376 00377 00378
HIT1000W/U/EURO/4K HIT 250W/U/EURO/5K HIT 400W/U/EURO/5K HIT 2000W/U/4K HIT 2000W/U/230V/45K HIT 1000W/U/LU/5K MH-DE 70W/10K MH-DE 150W/10K MH-DE 250W/10K HIT 250W/10K HIT 400W/10K HIE 1000W/V/LU/BT120/4K HIT 250W/U/LU/BDX HIT 250W/U/LU/GDX MH-DE 70W/UVS/BDX MH-DE 70W/UVS/GDX MH-DE 70W/UVS/PDX MH-DE 70W/UVS/MDX MH-DE 150W/UVS/PDX MH-DE 150W/UVS/MDX HIT 70W/G12/UVS/BDX HIT 70W/G12/UVS/GDX HIT 70W/G12/UVS/PDX HIT 70W/G12/UVS/MDX HIT 150W/G12/UVS/PDX HIT 150W/G12/UVS/MDX HIE 150W/U/LU/PDX HIE 150W/U/LU/MDX HIT 250W/U/LU/PDX HIT 250W/U/LU/MDX HIT 400W/U/LU/MDX HIT 1000W/U/LU/BDX HIT 1000W/U/LU/GDX HIT 400W/U/LU/BDX HIT 400W/U/LU/GDX HIT 400W/U/LU/PDX HIT 400W/U/EURO/MDX HIPT 250W/H75/UVS/T52/PS/4K HIPT 400W/H75/UVS/T52/PS/4K HIPT 200W/H75/UVS/T52/PS/4K HIPT 350W/H75/UVS/T52/PS/4K MH-DE 70W/6.5K MH-DE 70W/15K MH-DE 70W/20K MH-DE 150W/6.5K MH-DE 150W/15K MH-DE 150W/20K MH-DE 250W/6.5K MH-DE 250W/15K HIT 150W/6.5K HIT 150W/10K HIT 150W/15K HIT 150W/20K HIT 250W/6.5K HIT 250W/15K HIT 250W/20K HIT 400W/6.5K HIT 400W/15K HIT 400W/20K HIPT 250W/10K HIPT 400W/10K HIT1000W/U/EURO/5K HIT 1000W/HOR/4.5K CM-PLUS TC 20W/U/UVS/G8.5/830 CM-PLUS TC 20W/U/UVS/G8.5/942 CM-PLUS TC 35W/U/UVS/G8.5/830 CM-PLUS TC 35W/U/UVS/G8.5/942 CM-PLUS TC 70W/U/UVS/G8.5/830 CM-PLUS TC 70W/U/UVS/G8.5/942 CM-PLUS T 20W/U/UVS/G12/830 CM-PLUS T 20W/U/UVS/G12/942 CM-PLUS T 35W/U/UVS/G12/830 CM-PLUS T 35W/U/UVS/G12/942 CM-PLUS T 70W/U/UVS/G12/830 CM-PLUS T 70W/U/UVS/G12/942 CM-PLUS T 100W/U/UVS/G12/830 CM-PLUS T 100W/U/UVS/G12/942 CM-PLUS T 150W/U/UVS/G12/830 CM-PLUS T 150W/U/UVS/G12/942 CM-PLUS TD 70W/U/UVS/RX7s/830 CM-PLUS TD 70W/U/UVS/RX7s/942 CM-PLUS TD 150W/U/UVS/RX7s/830 CM-PLUS TD 150W/U/UVS/RX7s/942 CM-PLUS TT 70W/U/UVS/830 CM-PLUS TT 70W/U/UVS/942 CM-PLUS TT 100W/U/UVS/830 CM-PLUS TT 100W/U/UVS/942 CM-PLUS TT 150W/U/UVS/830
Wattage Category 1000 250 400 2000 2000 1000 70 150 250 250 400 1000 250 250 70 70 70 70 150 150 70 70 70 70 150 150 150 150 250 250 400 1000 1000 400 400 400 400 250 400 200 350 70 70 70 150 150 150 250 250 150 150 150 150 250 250 250 400 400 400 250 400 1000 1000 20 20 35 35 70 70 20 20 35 35 70 70 100 100 150 150 70 70 150 150 70 70 100 100 150
Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide White-Lux® Plus Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose White-Lux® Plus Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Designer Colour® Open rated Horizontal lamps Open rated Horizontal lamps Open rated Horizontal lamps Open rated Horizontal lamps Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Euro Metal Halide Euro Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide
Page 23 22 23 23 23 15 34 34 34 34 34 15 33 33 32 32 32 32 32 32 32 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 33 13 13 13 13 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 23 23 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31
Part No.
Description
00379 00380 00381 00382 00383 00384 00385 10002 10003 10004 10005 10006 10007 10016 10043 10050 10051 10076 10077 10079 10082 10103 10104 10138 10855 11295 12106 12108 12342 12445 12758 13090 13556 13742 15332 15556 16419 16786 17611 17611 18360 18477 18520 19031 19523 19525 20137 20137 20753 21044 21303 21303 21344 21714 21929 22132 22147 22149 22151 22417 22619 22822 22833 23660 24573 24729 25779 25830 26091 26786 27252 27373 27845 27965 29486 29963 30544 31545 31668 32147 32225 32519 32520 32658 32795 33051 33149 33479
CM-PLUS TT 150W/U/UVS/942 CM-PLUS ED 70W/U/UVS/830 CM-PLUS ED 70W/U/UVS/942 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/942 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/942 HIPE 70W/U/LU/UVS/4K HIPE 70W/C/U/LU/UVS/4K HIPE 100W/U/LU/UVS/4K HIPE 100W/C/U/LU/UVS/4K HIPE 150W/U/LU/UVS/4K HIPE 150W/C/U/LU/UVS/4K HIPE 250W/HBU/LU/UVS/4K HIPE 400W/C/V/LU/UVS/4K HIPE 100W/U/LU/E90/UVS/4K HIPE 150W/U/LU/E90/UVS/4K HIPE 250W/C/HBU/LU/UVS/4K HIPE 400W/V/LU/UVS/4K MS 450W/V/PS/740 HIPE 150W/C/U/LU/E90/UVS/4K MP 320W/BU/ED28/UVS/PS/740 MP 320W/C/BU/ED28/UVS/PS/737 MS 450W/C/V/PS/737 HIT 250W/U/LU/5K MH-DE 150W/UVS/3K HIT 150W/G12/UVS/3K HIT 70W/G12/UVS/3K MH 1500W/U/XL MP 400W/V/ED28/UVS/PS/740 MS 320W/C/H75/ED28/PS/737 MS 1000W/BU/BT37 MH 150W/U/ED28/PS/740 HIT 70W/U/LU/4K MH 1000W/U/BT37 MH 175W/U/MED MS 1650W/HOR/XP/SPORT60 MH-DE 70W/UVS/3K MP 400W/H75/UVS/PS/740 MP 400W/H75/UVS/PS/740 MH 1500W/HBU MS 250W/C/BU/3K MH 400W/U HIE 100W/C/U/LU/4K MP 250W/BU/UVS/PS/EM/950 MP 250W/C/BU/UVS/PS/EM/950 HIE 400W/U/EURO/4K HIE 400W/U/EURO/4K MH 400W/C/U/ED28 HIT 400W/U/LU/5K HIE 250W/C/U/EURO/4K HIE 250W/C/U/EURO/4K MH 150W/C/U/ED28/PS/737 MP 320W/BU/ED37/UVS/PS/740 MS 400W/HOR/ED28 MBIL S 2000W MP 200W/V/UVS/PS/740 MP 350W/V/UVS/PS/740 MBIL S 1500W MBIL S 1000W MS 875W/BU/BT37/PS/740 HIPE 150W/U/LU/UVS/3K HIPE 150W/C/U/LU/UVS/3K HIE 70W/U/LU/3K MS 400W/C/HOR/ED28 HIE 175W/C/U/E54/EURO/4K HIT 150W/G12/UVS/4K HIT 400W/U/EURO/4K MPI 400W/C/BU HIT 150W/G12/UVS/GDX MH 250W/U/5K HIE 70W/U/LU/4K MP 350W/C/V/UVS/PS/732 HIT 250W/H75/LU/4K HIPE 250W/C/H75/LU/UVS/4K MH-DE 150W/UVS/FS/6K HIE 150W/U/LU/4K HIE 400W/C/BU/EURO/4K HIE 250W/V/LU/4K MP 150W/C/U/ED28/UVS/PS/737 MS 400W/HOR/T15/3K MPI 175W/BU MPI 175W/C/BU MP 250W/C/BU/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/737 HIE 150W/U/LU/BDX MP 350W/BU/ED28/UVS/PS/EM/950 MH 250W/U/T15
Wattage Category 150 70 70 100 100 150 150 70 70 100 100 150 150 250 400 100 150 250 400 450 150 320 320 450 250 150 150 70 1500 400 320 1000 150 70 1000 175 1650 70 400 400 1500 250 400 100 250 250 400 400 400 400 250 250 150 320 400 2000 200 350 1500 1000 875 150 150 70 400 175 150 400 400 150 250 70 350 250 250 150 150 400 250 150 400 175 175 250 320 150 350 250
Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus White-Lux® Plus Uni-Form® Pulse Start - Enclosed White-Lux® Plus Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed White-Lux® Plus Double Ended G12 G12 Standard Metal Halide Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Standard Metal Halide Uni-Form® Pulse Start - Enclosed White-Lux® Plus Standard Metal Halide Standard Metal Halide Standard Metal Halide Double Ended Open rated Horizontal lamps Uni-Form® Pulse Start - Open Standard Metal Halide Standard Metal Halide Standard Metal Halide White-Lux® Plus Natural White® Natural White® Euro Metal Halide Standard Metal Halide Standard Metal Halide White-Lux® Plus Euro Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Standard Metal Halide High Wattage Lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open High Wattage Lamps High Wattage Lamps Uni-Form® Pulse Start - Enclosed White-Lux® Plus White-Lux® Plus White-Lux® Plus Standard Metal Halide Euro Metal Halide G12 Euro Metal Halide Standard Metal Halide Designer Colour® Standard Metal Halide White-Lux® Plus Uni-Form® Pulse Start - Open White-Lux® Plus White-Lux® Plus Double Ended White-Lux® Plus Euro Metal Halide White-Lux® Plus Uni-Form® Pulse Start - Open Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Designer Colour® Natural White® Standard Metal Halide
Page 31 31 31 31 31 31 31 14 14 14 14 14 14 15 15 14 14 15 15 17 14 18 18 17 15 28 28 28 25 19 16 25 16 15 25 24 25 28 13 19 25 24 24 14 20 20 23 25 24 15 22 25 16 18 24 27 18 18 27 27 17 14 14 14 24 22 28 23 25 32 24 14 18 15 15 28 14 23 15 18 24 25 25 18 18 32 20 24
Wattage Category 150 150 400 875 150 250 875 1000 175 250 400 350 100 400 400 400 400 150 175 875 150 400 400 250 400 350 200 100 400 400 1500 350 1000 320 350 70 250 1000 250 250 250 100 350 320 70 350 70 1000 600 400 250 400 175 400 350 400 400 250 400 175 400 250 320 250 200 400 400 875 150 200 320 450 400 70 250 250 200 200 250 150 250 70 175 250 400 400 400 250
Designer Colour® Designer Colour® Euro Metal Halide Uni-Form® Pulse Start - Enclosed Designer Colour® Euro Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Euro Metal Halide Standard Metal Halide Standard Metal Halide Natural White® White-Lux® Plus Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide White-Lux® Plus White-Lux® Plus Euro Metal Halide Uni-Form® Pulse Start - Open White-Lux® Plus White-Lux® Plus Uni-Form® Pulse Start - Enclosed White-Lux® Plus White-Lux® Plus Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open White-Lux® Plus Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed High Wattage Lamps Uni-Form® Pulse Start - Enclosed Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open White-Lux® Plus White-Lux® Plus Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Open rated Horizontal lamps Uni-Form® Pulse Start - Open White-Lux® Plus Natural White® Uni-Form® Pulse Start - Enclosed White-Lux® Plus Uni-Form® Pulse Start - Enclosed G12 Standard Metal Halide White-Lux® Plus White-Lux® Plus Standard Metal Halide White-Lux® Plus Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Open Standard Metal Halide Uni-Form® Pulse Start - Enclosed White-Lux® Plus Natural White® Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Euro Metal Halide Uni-Form® Pulse Start - Enclosed Euro Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open White-Lux® Plus Double Ended Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide White-Lux® Plus Standard Metal Halide White-Lux® Plus Standard Metal Halide White-Lux® Plus Euro Metal Halide Designer Colour® Standard Metal Halide Uni-Form® Pulse Start - Open
Page 32 32 23 17 32 22 17 25 22 24 24 20 14 24 17 24 15 14 22 19 14 15 17 15 15 18 18 14 19 17 27 17 25 16 18 14 15 17 16 13 18 14 20 16 14 17 28 25 15 15 24 15 24 24 18 24 17 15 20 24 24 16 16 22 16 23 17 19 18 18 16 19 15 28 25 25 16 16 24 15 24 14 24 15 23 33 24 18
Part No.
Description
64866 65072 65218 65218 65850 66506 67331 67712 68110 69876 70310 70345 70764 71144 71329 71642 71722 72051 72315 72748 72843 73531 74756 76738 77594 78952 79457 79470 79710 81054 81202 81203 81365 82070 82539 83265 83545 84203 84629 84684 84727 84971 85260 87368 88246 88246 88342 88353 88410 88460 88648 88787 88787 88791 89113 89410 93749 94102 94883 95123 95320 95321 95527 96627 96720 97354 97731 98389 98520 98530 98748 99441 V100SSB255 V100SSC255 V150SSB255 V150SSC255 V20MSB255 V20MSC255 V25MSB255 V25MSC255 V35MSB255 V35MSC255 V50MSB255 V50MSC255 V70MSB255 V70MSC255
MS 350W/C/H75/PS/737 MP 450W/BU/UVS/PS/740 MP 350W/H75/UVS/PS/740 MP 350W/H75/UVS/PS/740 HIPE 100W/C/U/LU/UVS/3K MP 320W/C/BU/ED37/UVS/PS/732 HIE 50W/U/LU/4K MS 320W/C/V/ED37/PS/737 HIE 400W/C/H75/LU/4K HIE 150W/C/U/LU/3K MS 175W/BU/MED MS 200W/C/V/PS/737 MS 200W/H75/T15/PS/740 HIT 150W/U/LU/T46/4K MS 350W/C/V/PS/737 MP 400W/V/UVS/PS/740 MS 1000W/BU/BT37/PS/740 MH 1000W/U MP 400W/BU/ED28/UVS/PS/EM/950 MH-DE 250W/4K/Fc2 MP 350W/C/V/MD/UVS/PS MS 400W/V/PS/740 MH-DE 150W/UVS/4K HIT 100W/U/LU/T38/4K MS 320W/C/V/ED28/PS/737 MS 1000W/BU/T25 HIE 100W/U/LU/3K MH-DE 70W/UVS/FS/6K MS 320W/H75/T15/L/PS/740 MS 250W/H75/PS/740 HIE 250W/C/BU/EURO/4K HIE 250W/BU/EURO/4K MS 250W/C/V/PS/737 MS 1500W/HOR/XP/SPORT60 HIPE 100W/U/LU/UVS/3K HIT 1000W/U/LU/4K MH 400W/C/U MH-TS 2000W/L/K12/4K MP 400W/C/V/MD/UVS/PS HIT 150W/G12/UVS/BDX MH-DE 250W/3K/Fc2 HIE 175W/U/E54/EURO/4K MS 400W/V/ED28/PS/740 HIT 100W/U/LU/T46/4K HIE 250W/U/EURO/4K HIE 250W/U/EURO/4K HIT 400W/U/EURO/BDX MS 250W/HOR/T15 HIT 400W/HOR/EURO/4K MH 1000W/C/U MP 400W/C/V/ED28/UVS/PS/737 HIE 400W/C/U/EURO/4K HIE 400W/C/U/EURO/4K MH 175W/U MS 1000W/BU MP 400W/C/BU/UVS/PS/EM/950 MS 350W/H75/T15/PS/740 HIPE 400W/C/BU/EURO/4K MS 250W/HOR MP 320W/C/BU/ED37/UVS/PS/EM/950 MP 320W/H75/T15/S//UVS/PS/EM/950 MP 320W/H75/T15/L//UVS/PS/EM/950 MPI 400W/BU MH 175W/C/U HIE 70W/C/U/LU/3K HIT 400W/U/EURO/PDX HIT 400W/H75/WLC/UVS/35K MS 350W/V/PS/740 MP 320W/BU/ED37/UVS/PS/EM/950 MP 320W/BU/ED28/UVS/PS/EM/950 HIT 400W/U/LU/4K HIPE 400W/BU/EURO/4K V100SSB255 V100SSC255 V150SSB255 V150SSC255 V20MSB255 V20MSC255 V25MSB255 V25MSC255 V35MSB255 V35MSC255 V50MSB255 V50MSC255 V70MSB255 V70MSC255
Wattage Category 350 450 350 350 100 320 50 320 400 150 175 200 200 150 350 400 1000 1000 400 250 350 400 150 100 320 1000 100 70 320 250 250 250 250 1500 100 1000 400 2000 400 150 250 175 400 100 250 250 400 250 400 1000 400 400 400 175 1000 400 350 400 250 320 320 320 400 175 70 400 400 350 320 320 400 400 100 100 150 150 20 20 25 25 35 35 50 50 70 70
Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Open rated Horizontal lamps Uni-Form® Pulse Start - Open White-Lux® Plus Uni-Form® Pulse Start - Open White-Lux® Plus Uni-Form® Pulse Start - Enclosed White-Lux® Plus White-Lux® Plus Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed White-Lux® Plus Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Standard Metal Halide Natural White® Double Ended Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Enclosed Double Ended White-Lux® Plus Uni-Form® Pulse Start - Enclosed Standard Metal Halide White-Lux® Plus Double Ended Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Euro Metal Halide Euro Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide White-Lux® Plus White-Lux® Plus Standard Metal Halide High Wattage Lamps Uni-Form® Pulse Start - Open Designer Colour® Double Ended Euro Metal Halide Uni-Form® Pulse Start - Enclosed White-Lux® Plus Euro Metal Halide Standard Metal Halide Designer Colour® Standard Metal Halide Euro Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Open Euro Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Natural White® Uni-Form® Pulse Start - Enclosed Euro Metal Halide Standard Metal Halide Natural White® Natural White® Natural White® Standard Metal Halide Standard Metal Halide White-Lux® Plus Designer Colour® White-Lux® Plus Uni-Form® Pulse Start - Enclosed Natural White® Natural White® White-Lux® Plus Euro Metal Halide Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear
Page 17 19 13 18 14 18 14 16 15 14 24 16 16 15 17 19 17 25 20 28 18 17 28 15 16 25 14 28 16 16 22 22 16 25 14 15 24 27 19 32 28 22 17 15 22 25 33 24 23 25 19 23 25 24 25 20 17 23 24 20 20 20 25 24 14 33 15 17 20 20 15 23 36 36 36 36 36 36 36 36 36 36 36 36 36 36
Index by Part Number
Description MH-DE 150W/UVS/BDX HIE 150W/U/LU/GDX HIE 400W/BU/EURO/4K MS 875W/HOR/BT37/PS/740 MH-DE 150W/UVS/GDX HIT 250W/U/EURO/4K MS 875W/BD/BT37/PS/740 MH 1000W/U/5K HIE 175W/U/EURO/4K MS 250W/BU MH 400W/U/5K MP 350W/C/BU/UVS/PS/EM/950 HIPE 100W/C/V/LU/UVS/27K MS 400W/BU/ED28 MS 400W/H75/ED28/PS/740 MS 400W/HOR HIPE 400W/C/H75/LU/UVS/4K HIE 150W/C/U/LU/4K HIE 175W/C/U/EURO/4K MP 875W/C/BU/BT37/PS/737 HIPE 150W/C/V/LU/UVS/27K HIPE 400W/C/V/LU/UVS/HO/4K MS 400W/C/V/PS/737 HIE 250W/C/H75/LU/4K HIT 400W/H75/LU/4K MP 350W/C/V/UVS/PS/737 MP 200W/C/V/UVS/PS/732 HIE 100W/C/U/LU/3K MP 400W/C/V/UVS/PS/737 MS 400W/C/V/ED28/PS/737 MH-DE 1500W/T7/4K MS 350W/H75/ED28/PS/740 MS 1000W/HOR/SPORT 60 MS 320W/H75/ED28/PS/740 MP 350W/V/ED28/UVS/PS/740 HIPE 70W/C/V/LU/UVS/27K HIT 250W/U/LU/4K MS 1000W/HOR/T25/PS/734 MS 250W/V/PS/740 MP 250W/H75/UVS/PS/740 MP 250W/H75/UVS/PS/740 HIE 100W/U/LU/4K MP 350W/BU/UVS/PS/950 MS 320W/V/ED37/PS/740 HIPE 70W/C/U/LU/UVS/3K MS 350W/V/ED28/PS/740 HIT 70W/G12/UVS/4K MS 1000W/HOR/BT37/3K HIT 600W/U/LU/4K HIE 400W/C/V/LU/4K MS 250W/HOR/T15/3K HIPE 400W/V/LU/UVS/HO/4K MS 175W/BU MS 400W/HOR/T15 MP 350W/C/V/ED28/UVS/PS/737 MH 400W/U/T15 MS 400W/C/H75/ED28/PS/737 HIE 250W/C/V/LU/4K MP 400W/BU/UVS/PS/EM/950 MS 175W/HOR MH 400W/U/ED28 MS 250W/H75/T15/PS/740 MS 320W/H75/T15/S/PS/740 HIT 250W/HOR/EURO/4K MS 200W/V/PS/740 HIE 400W/C/U/E90/EURO/4K* MS 400W/H75/PS/740 MP 875W/BU/BT37/PS/740 MP 150W/U/ED28/UVS/PS/740 MP 200W/C/V/UVS/PS/737 MS 320W/V/ED28/PS/740 MP 450W/C/BU/UVS/PS/737 HIE 400W/V/LU/4K MH-DE 70W/UVS/4K MPI 250W/BU MPI 250W/C/BU MS 200W/BU/MED/PS/740 MS 200W/C/BU/MED/PS/737 MH 250W/C/U HIT 150W/U/LU/T38/4K MH 250W/U HIE 70W/C/U/LU/4K MH 175W/C/U/MED HIT 250W/H75/WLC/UVS/35K HIE 400W/C/HOR/EURO/4K HIT 400W/U/EURO/GDX MS 400W/C/HOR MP 250W/BU/UVS/PS/740
Venture
Part No. 33496 33520 33544 33759 33851 33950 35426 35914 36279 36297 36813 38197 39468 40013 40124 40509 40511 40563 40698 41686 41700 42068 42401 43634 43898 44097 44872 45157 45541 46416 46745 46959 47503 47549 47887 48692 48768 49111 49621 49822 49822 50340 51628 52236 52910 52980 52983 53702 54631 54695 54843 54918 55087 55100 55401 55422 55459 56266 57129 57330 57540 57625 57626 57712 57739 58122 58788 58953 58963 59174 59194 59216 60112 60248 60722 60723 60811 60812 61290 62272 63052 63173 63187 63736 63958 64390 64648 64658
59
Index by Description
60
Description
Part No.
CM-PLUS ED 70W/U/UVS/830 CM-PLUS ED 70W/U/UVS/942 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/830 CM-PLUS ED 150W/U/UVS/942 CM-PLUS ED 150W/U/UVS/942 CM-PLUS T 20W/U/UVS/G12/830 CM-PLUS T 20W/U/UVS/G12/942 CM-PLUS T 35W/U/UVS/G12/830 CM-PLUS T 35W/U/UVS/G12/942 CM-PLUS T 70W/U/UVS/G12/830 CM-PLUS T 70W/U/UVS/G12/942 CM-PLUS T 100W/U/UVS/G12/830 CM-PLUS T 100W/U/UVS/G12/942 CM-PLUS T 150W/U/UVS/G12/830 CM-PLUS T 150W/U/UVS/G12/942 CM-PLUS TC 20W/U/UVS/G8.5/830 CM-PLUS TC 20W/U/UVS/G8.5/942 CM-PLUS TC 20W/U/UVS/G8.5/942 CM-PLUS TC 35W/U/UVS/G8.5/830 CM-PLUS TC 70W/U/UVS/G8.5/830 CM-PLUS TC 70W/U/UVS/G8.5/942 CM-PLUS TD 70W/U/UVS/RX7s/830 CM-PLUS TD 70W/U/UVS/RX7s/942 CM-PLUS TD 150W/U/UVS/RX7s/830 CM-PLUS TD 150W/U/UVS/RX7s/942 CM-PLUS TT 70W/U/UVS/830 CM-PLUS TT 70W/U/UVS/942 CM-PLUS TT 100W/U/UVS/830 CM-PLUS TT 100W/U/UVS/942 CM-PLUS TT 150W/U/UVS/830 CM-PLUS TT 150W/U/UVS/942 HIE 50W/U/LU/4K HIE 70W/C/U/LU/3K HIE 70W/C/U/LU/4K HIE 70W/U/LU/3K HIE 70W/U/LU/4K HIE 100W/C/U/LU/3K HIE 100W/C/U/LU/4K HIE 100W/U/LU/3K HIE 100W/U/LU/4K HIE 150W/C/U/LU/3K HIE 150W/C/U/LU/4K HIE 150W/U/LU/4K HIE 150W/U/LU/BDX HIE 150W/U/LU/GDX HIE 150W/U/LU/MDX HIE 150W/U/LU/PDX HIE 175W/C/U/E54/EURO/4K HIE 175W/C/U/EURO/4K HIE 175W/U/E54/EURO/4K HIE 175W/U/EURO/4K HIE 250W/BU/EURO/4K HIE 250W/C/BU/EURO/4K HIE 250W/C/H75/LU/4K HIE 250W/C/U/EURO/4K HIE 250W/C/U/EURO/4K HIE 250W/C/V/LU/4K HIE 250W/U/EURO/4K HIE 250W/U/EURO/4K HIE 250W/V/LU/4K HIE 400W/BU/EURO/4K HIE 400W/C/BU/EURO/4K HIE 400W/C/H75/LU/4K HIE 400W/C/HOR/EURO/4K HIE 400W/C/U/E90/EURO/4K* HIE 400W/C/U/EURO/4K HIE 400W/C/U/EURO/4K HIE 400W/C/V/LU/4K HIE 400W/U/EURO/4K HIE 400W/U/EURO/4K HIE 400W/V/LU/4K HIE 1000W/V/LU/BT120/4K HIPE 70W/C/U/LU/UVS/3K HIPE 70W/C/U/LU/UVS/4K HIPE 70W/C/V/LU/UVS/27K HIPE 70W/U/LU/UVS/4K HIPE 100W/C/U/LU/UVS/3K HIPE 100W/C/U/LU/UVS/4K HIPE 100W/C/V/LU/UVS/27K HIPE 100W/U/LU/E90/UVS/4K HIPE 100W/U/LU/UVS/3K HIPE 100W/U/LU/UVS/4K HIPE 150W/C/U/LU/E90/UVS/4K HIPE 150W/C/U/LU/UVS/3K HIPE 150W/C/U/LU/UVS/4K HIPE 150W/C/V/LU/UVS/27K HIPE 150W/U/LU/E90/UVS/4K
00380 00381 00382 00384 00383 00385 00360 00361 00362 00363 00364 00365 00366 00367 00368 00369 00354 00355 00357 00356 00358 00359 00370 00371 00372 00373 00374 00375 00376 00377 00378 00379 67331 96720 63173 23660 27373 45157 19031 79457 50340 69876 40563 30544 33051 33520 00190 00189 24729 40698 84971 36279 81203 81202 43634 21303 21303 56266 88246 88246 31668 33544 31545 68110 63958 58122 88787 88787 54695 20137 20137 60112 154 52910 10003 48692 10002 65850 10005 39468 10050 82539 10004 10082 22833 10007 41700 10051
Wattage Category 70 70 100 150 100 150 20 20 35 35 70 70 100 100 150 150 20 20 35 35 70 70 70 70 150 150 70 70 100 100 150 150 50 70 70 70 70 100 100 100 100 150 150 150 150 150 150 150 175 175 175 175 250 250 250 250 250 250 250 250 250 400 400 400 400 400 400 400 400 400 400 400 1000 70 70 70 70 100 100 100 100 100 100 150 150 150 150 150
Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide Ceramic Master Plus Metal Halide White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus Designer Colour® Designer Colour® Designer Colour® Designer Colour® Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide White Lux® Plus Euro Metal Halide Standard Metal Halide White Lux® Plus Euro Metal Halide Standard Metal Halide White Lux® Plus Euro Metal Halide Euro Metal Halide White Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide Standard Metal Halide White Lux® Plus Euro Metal Halide Standard Metal Halide White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus
Page 31 31 31 31 31 31 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 14 14 14 14 14 14 14 14 14 14 14 14 32 32 32 32 22 22 22 22 22 22 15 22 25 15 22 25 15 23 23 15 23 23 23 25 15 23 25 15 15 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14
Description
Part No.
HIPE 150W/U/LU/UVS/3K HIPE 150W/U/LU/UVS/4K HIPE 250W/C/H75/LU/UVS/4K HIPE 250W/C/HBU/LU/UVS/4K HIPE 250W/HBU/LU/UVS/4K HIPE 400W/BU/EURO/4K HIPE 400W/C/BU/EURO/4K HIPE 400W/C/H75/LU/UVS/4K HIPE 400W/C/V/LU/UVS/4K HIPE 400W/C/V/LU/UVS/HO/4K HIPE 400W/V/LU/UVS/4K HIPE 400W/V/LU/UVS/HO/4K HIPT 200W/H75/UVS/T52/PS/4K HIPT 250W/10K HIPT 250W/H75/UVS/T52/PS/4K HIPT 350W/H75/UVS/T52/PS/4K HIPT 400W/10K HIPT 400W/H75/UVS/T52/PS/4K HIT 70W/G12/UVS/3K HIT 70W/G12/UVS/4K HIT 70W/G12/UVS/BDX HIT 70W/G12/UVS/GDX HIT 70W/G12/UVS/MDX HIT 70W/G12/UVS/PDX HIT 70W/U/LU/4K HIT 100W/U/LU/T38/4K HIT 100W/U/LU/T46/4K HIT 150W/10K HIT 150W/15K HIT 150W/20K HIT 150W/6.5K HIT 150W/G12/UVS/3K HIT 150W/G12/UVS/4K HIT 150W/G12/UVS/BDX HIT 150W/G12/UVS/GDX HIT 150W/G12/UVS/MDX HIT 150W/G12/UVS/PDX HIT 150W/U/LU/T38/4K HIT 150W/U/LU/T46/4K HIT 250W/10K HIT 250W/15K HIT 250W/20K HIT 250W/6.5K HIT 250W/H75/LU/4K HIT 250W/H75/WLC/UVS/35K HIT 250W/HOR/EURO/4K HIT 250W/U/EURO/4K HIT 250W/U/EURO/5K HIT 250W/U/LU/4K HIT 250W/U/LU/5K HIT 250W/U/LU/BDX HIT 250W/U/LU/GDX HIT 250W/U/LU/MDX HIT 250W/U/LU/PDX HIT 400W/10K HIT 400W/15K HIT 400W/20K HIT 400W/6.5K HIT 400W/H75/LU/4K HIT 400W/H75/WLC/UVS/35K HIT 400W/HOR/EURO/4K HIT 400W/U/EURO/4K HIT 400W/U/EURO/5K HIT 400W/U/EURO/BDX HIT 400W/U/EURO/GDX HIT 400W/U/EURO/MDX HIT 400W/U/EURO/PDX HIT 400W/U/LU/4K HIT 400W/U/LU/5K HIT 400W/U/LU/BDX HIT 400W/U/LU/GDX HIT 400W/U/LU/MDX HIT 400W/U/LU/PDX HIT 600W/U/LU/4K HIT 1000W/HOR/4.5K HIT 1000W/U/LU/4K HIT 1000W/U/LU/5K HIT 1000W/U/LU/BDX HIT 1000W/U/LU/GDX HIT1000W/U/EURO/4K HIT1000W/U/EURO/5K HIT 2000W/U/230V/45K HIT 2000W/U/4K MBIL S 1000W MBIL S 1500W MBIL S 2000W MH 150W/C/U/ED28/PS/737 MH 150W/U/ED28/PS/740
22822 10006 29486 10076 10016 99441 94102 40511 10043 42068 10077 54918 00247 00275 00245 00248 00276 00246 12108 52983 00183 00184 00186 00185 13742 76738 87368 00265 00266 00267 00264 12106 25779 84684 26786 00188 00187 62272 71144 00146 00269 00270 00268 27965 63736 57712 33950 00033 48768 10855 00163 00164 00192 00191 00147 00272 00273 00271 43898 97731 88410 25830 00034 88342 64390 00242 97354 98748 21044 00239 00240 00194 00241 54631 00336 83265 00083 00195 00196 00008 00282 00067 00066 22417 22151 22132 21344 13556
Wattage Category 150 150 250 250 250 400 400 400 400 400 400 400 200 250 250 350 400 400 70 70 70 70 70 70 70 100 100 150 150 150 150 150 150 150 150 150 150 150 150 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 600 1000 1000 1000 1000 1000 1000 1000 2000 2000 1000 1500 2000 150 150
White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus Euro Metal Halide Euro Metal Halide White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus White Lux® Plus Open rated Horizontal lamps Aquatic & Special Purpose Open rated Horizontal lamps Open rated Horizontal lamps Aquatic & Special Purpose Open rated Horizontal lamps G12 G12 Designer Colour®® Designer Colour® Designer Colour® Designer Colour® White Lux® Plus White Lux® Plus White Lux® Plus Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose G12 G12 Designer Colour® Designer Colour® Designer Colour® Designer Colour® White Lux® Plus White Lux® Plus Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose White Lux® Plus White Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide White Lux® Plus White Lux® Plus Designer Colour® Designer Colour® Designer Colour® Designer Colour® Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose White Lux® Plus White Lux® Plus Euro Metal Halide Euro Metal Halide Euro Metal Halide Designer Colour® Designer Colour® Designer Colour® Designer Colour® White Lux® Plus White Lux® Plus Designer Colour® Designer Colour® Designer Colour® Designer Colour® White Lux® Plus Euro Metal Halide White Lux® Plus White Lux® Plus Designer Colour® Designer Colour® Euro Metal Halide Euro Metal Halide Euro Metal Halide Euro Metal Halide High Wattage Lamps High Wattage Lamps High Wattage Lamps Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed
Page 14 14 15 15 15 23 23 15 15 15 15 15 13 34 13 13 34 13 28 28 32 32 32 32 15 15 15 34 34 34 34 28 28 32 32 32 32 15 15 34 34 34 34 15 15 22 22 22 15 15 33 33 33 33 34 34 34 34 15 15 23 23 23 33 33 33 33 15 15 33 33 33 33 15 23 15 15 33 33 23 23 23 23 27 27 27 16 16
Wattage Category 175 175 175 175 250 250 250 250 400 400 400 400 400 400 1000 1000 1000 1000 1500 1500 70 70 70 70 70 70 70 70 70 70 70 150 150 150 150 150 150 150 150 150 150 150 250 250 250 250 250 1500 2000 150 150 200 200 200 250 250 250 250 250 250 320 320 320 320 320 320 320 320 320 320 350 350 350 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400
Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Designer Colour® Double Ended Designer Colour® Designer Colour® Designer Colour® Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Designer Colour® Double Ended Designer Colour® Designer Colour® Designer Colour® Aquatic & Special Purpose Aquatic & Special Purpose Double Ended Double Ended Aquatic & Special Purpose High Wattage Lamps High Wattage Lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Open rated Horizontal lamps Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Natural White® Natural White® Natural White® Natural White® Natural White® Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Open rated Horizontal lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Natural White® Natural White® Natural White® Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open
Page 24 24 24 24 24 24 24 24 24 24 24 24 24 24 25 25 25 25 25 25 34 34 34 34 28 28 32 28 32 32 32 34 34 34 34 28 28 32 28 32 32 32 34 34 28 28 34 27 27 18 18 18 18 18 18 20 18 20 18 13 18 20 18 20 18 18 18 20 20 20 20 20 20 18 18 18 18 13 18 18 18 20 20 20 19 19 19 19
Description
Part No.
MP 400W/H75/UVS/PS/740 MP 400W/V/ED28/UVS/PS/740 MP 400W/V/UVS/PS/740 MP 450W/BU/UVS/PS/740 MP 450W/C/BU/UVS/PS/737 MP 875W/BU/BT37/PS/740 MP 875W/C/BU/BT37/PS/737 MPI 175W/BU MPI 175W/C/BU MPI 250W/BU MPI 250W/C/BU MPI 400W/BU MPI 400W/C/BU MS 175W/BU MS 175W/BU/MED MS 175W/HOR MS 200W/BU/MED/PS/740 MS 200W/C/BU/MED/PS/737 MS 200W/C/V/PS/737 MS 200W/H75/T15/PS/740 MS 200W/V/PS/740 MS 250W/BU MS 250W/C/BU/3K MS 250W/C/V/PS/737 MS 250W/H75/PS/740 MS 250W/H75/T15/PS/740 MS 250W/HOR MS 250W/HOR/T15 MS 250W/HOR/T15/3K MS 250W/V/PS/740 MS 320W/C/H75/ED28/PS/737 MS 320W/C/V/ED28/PS/737 MS 320W/C/V/ED37/PS/737 MS 320W/H75/ED28/PS/740 MS 320W/H75/T15/L/PS/740 MS 320W/H75/T15/S/PS/740 MS 320W/V/ED28/PS/740 MS 320W/V/ED37/PS/740 MS 350W/C/H75/PS/737 MS 350W/C/V/PS/737 MS 350W/H75/ED28/PS/740 MS 350W/H75/T15/PS/740 MS 350W/V/ED28/PS/740 MS 350W/V/PS/740 MS 400W/BU/ED28 MS 400W/C/H75/ED28/PS/737 MS 400W/C/HOR MS 400W/C/HOR/ED28 MS 400W/C/V/ED28/PS/737 MS 400W/C/V/PS/737 MS 400W/H75/ED28/PS/740 MS 400W/H75/PS/740 MS 400W/HOR MS 400W/HOR/ED28 MS 400W/HOR/T15 MS 400W/HOR/T15/3K MS 400W/V/ED28/PS/740 MS 400W/V/PS/740 MS 450W/C/V/PS/737 MS 450W/V/PS/740 MS 875W/BD/BT37/PS/740 MS 875W/BU/BT37/PS/740 MS 875W/HOR/BT37/PS/740 MS 1000W/BU MS 1000W/BU/BT37 MS 1000W/BU/BT37/PS/740 MS 1000W/BU/T25 MS 1000W/HOR/BT37/3K MS 1000W/HOR/SPORT 60 MS 1000W/HOR/T25/PS/734 MS 1500W/HOR/XP/SPORT60 MS 1650W/HOR/XP/SPORT60 V20MSB255 V20MSC255 V25MSB255 V25MSC255 V35MSB255 V35MSC255 V50MSB255 V50MSC255 V70MSB255 V70MSC255 V100SSB255 V100SSC255 V150SSB255 V150SSC255
17611 12445 71642 65072 59216 58953 41686 32519 32520 60722 60723 95527 26091 55087 70310 57330 60811 60812 70345 70764 57739 36297 18477 81365 81054 57625 94883 88353 54843 49621 12758 77594 67712 47549 79710 57626 59194 52236 64866 71329 46959 93749 52980 98389 40013 55459 64648 24573 46416 42401 40124 58788 40509 21929 55100 32225 85260 73531 10138 10079 35426 22619 33759 89113 13090 71722 78952 53702 47503 49111 82070 16419 V20MSB255 V20MSC255 V25MSB255 V25MSC255 V35MSB255 V35MSC255 V50MSB255 V50MSC255 V70MSB255 V70MSC255 V100SSB255 V100SSC255 V150SSB255 V150SSC255
Wattage Category 400 400 400 450 450 875 875 175 175 250 250 400 400 175 175 175 200 200 200 200 200 250 250 250 250 250 250 250 250 250 320 320 320 320 320 320 320 320 350 350 350 350 350 350 400 400 400 400 400 400 400 400 400 400 400 400 400 400 450 450 875 875 875 1000 1000 1000 1000 1000 1000 1000 1500 1650 20 20 25 25 35 35 50 50 70 70 100 100 150 150
Open rated Horizontal lamps Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Uni-Form® Pulse Start - Open Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Standard Metal Halide Uni-Form® Pulse Start - Enclosed Standard Metal Halide Standard Metal Halide Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear Ventronic Electronic Control Gear
Page 13 19 19 19 19 19 19 25 25 25 25 25 25 24 24 24 16 16 16 16 16 24 24 16 16 16 24 24 24 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 24 17 24 24 17 17 17 17 24 24 24 24 17 17 17 17 17 17 17 25 25 17 25 25 25 17 25 25 36 36 36 36 36 36 36 36 36 36 36 36 36 36
Index by Description
Part No. 96627 63187 88791 15556 61290 63052 27252 33479 83545 20753 18520 36813 57540 55422 88460 72051 35914 15332 18360 12342 00143 00256 00257 00255 16786 60248 00177 79470 00178 00180 00179 00144 00259 00260 00258 11295 74756 33496 29963 33851 00182 00181 00145 00262 84727 72748 00261 46745 84203 32147 58963 44872 59174 22147 64658 19523 32658 19525 49822 49822 10103 98530 21714 98520 10104 66506 32795 95123 95321 95320 33149 51628 38197 55401 72843 27845 44097 65218 65218 47887 22149 72315 57129 89410 88648 84629 45541 17611
Venture
Description MH 175W/C/U MH 175W/C/U/MED MH 175W/U MH 175W/U/MED MH 250W/C/U MH 250W/U MH 250W/U/5K MH 250W/U/T15 MH 400W/C/U MH 400W/C/U/ED28 MH 400W/U MH 400W/U/5K MH 400W/U/ED28 MH 400W/U/T15 MH 1000W/C/U MH 1000W/U MH 1000W/U/5K MH 1000W/U/BT37 MH 1500W/HBU MH 1500W/U/XL MH-DE 70W/10K MH-DE 70W/15K MH-DE 70W/20K MH-DE 70W/6.5K MH-DE 70W/UVS/3K MH-DE 70W/UVS/4K MH-DE 70W/UVS/BDX MH-DE 70W/UVS/FS/6K MH-DE 70W/UVS/GDX MH-DE 70W/UVS/MDX MH-DE 70W/UVS/PDX MH-DE 150W/10K MH-DE 150W/15K MH-DE 150W/20K MH-DE 150W/6.5K MH-DE 150W/UVS/3K MH-DE 150W/UVS/4K MH-DE 150W/UVS/BDX MH-DE 150W/UVS/FS/6K MH-DE 150W/UVS/GDX MH-DE 150W/UVS/MDX MH-DE 150W/UVS/PDX MH-DE 250W/10K MH-DE 250W/15K MH-DE 250W/3K/Fc2 MH-DE 250W/4K/Fc2 MH-DE 250W/6.5K MH-DE 1500W/T7/4K MH-TS 2000W/L/K12/4K MP 150W/C/U/ED28/UVS/PS/737 MP 150W/U/ED28/UVS/PS/740 MP 200W/C/V/UVS/PS/732 MP 200W/C/V/UVS/PS/737 MP 200W/V/UVS/PS/740 MP 250W/BU/UVS/PS/740 MP 250W/BU/UVS/PS/EM/950 MP 250W/C/BU/UVS/PS/737 MP 250W/C/BU/UVS/PS/EM/950 MP 250W/H75/UVS/PS/740 MP 250W/H75/UVS/PS/740 MP 320W/BU/ED28/UVS/PS/740 MP 320W/BU/ED28/UVS/PS/EM/950 MP 320W/BU/ED37/UVS/PS/740 MP 320W/BU/ED37/UVS/PS/EM/950 MP 320W/C/BU/ED28/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/732 MP 320W/C/BU/ED37/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/EM/950 MP 320W/H75/T15/L//UVS/PS/EM/950 MP 320W/H75/T15/S//UVS/PS/EM/950 MP 350W/BU/ED28/UVS/PS/EM/950 MP 350W/BU/UVS/PS/950 MP 350W/C/BU/UVS/PS/EM/950 MP 350W/C/V/ED28/UVS/PS/737 MP 350W/C/V/MD/UVS/PS MP 350W/C/V/UVS/PS/732 MP 350W/C/V/UVS/PS/737 MP 350W/H75/UVS/PS/740 MP 350W/H75/UVS/PS/740 MP 350W/V/ED28/UVS/PS/740 MP 350W/V/UVS/PS/740 MP 400W/BU/ED28/UVS/PS/EM/950 MP 400W/BU/UVS/PS/EM/950 MP 400W/C/BU/UVS/PS/EM/950 MP 400W/C/V/ED28/UVS/PS/737 MP 400W/C/V/MD/UVS/PS MP 400W/C/V/UVS/PS/737 MP 400W/H75/UVS/PS/740
61
Advanced Lighting Technologies Australia Inc.
Advanced Lighting Technologies New Zealand Ltd
Advanced Lighting Technologies Asia Pte Ltd
110 Lewis Road Wantirna South VIC. AUSTRALIA 3152
8 Boeing Place Mount Maunganui NEW ZEALAND
Block 4008, Ang Mo Kio Avenue 10 #04-06, Techplace I SINGAPORE 569625
T: 61 3 9800 5600 F: 61 3 9800 5533 E: sales@adlt.com.au
T: 64 7 579 0163 F: 64 7 579 0164 E: light@adlt.co.nz
T : 65 6844 2338 F: 65 6844 2339 E: sales@adlt.com.sg
www.adlt.com.au www.venturelighting.com.au
www.adlt.co.nz www.venturelighting.co.nz
www.adlt.com.sg www.venturelighting.com.sg
North America (World Headquarters)
Middle-East
Japan
Venture Lighting International 10295 Philipp Parkway Streetsboro, Ohio 44241 USA
Venture Lighting International FZE P.O. Box 16994 Jebel Ali Free Zone Dubai, U.A.E
Venture Lighting Japan Inc. Bunmeido Bldg. 6F 16-5, Taito 3-Chome Taito-Ku, Tokyo 110
T: (971-4) 883-7370 F: (971-4) 883-7371 E: ventufze@emirates.net.ae
T: (81) 03-3839-5711 F: (81) 03-3839-3724 E: vljapan@adlt.com
Canada
South Africa
India
Venture Lighting Power Systems 6889 Rexwood Road Units 6&7 Mississauge, Ontario Canada L4V 1RT
Venture Lighting South Africa (PTY.) LTD. Unit 44, Boulevard Way Capricorn Business Park Marina Da Gama, South Africa
Venture Lighting India Plot No. A30 D5 Phase II Zone B, MEPZ Tambaram, Chennai India 600045
T: 905-678-6291 F: 905-678-2879 E: venturecanadasales@adlt.com
T: (27) 21-709-0180 F: (27) 21-709-0198 E: vli-sa@iafrica.com
T: (91) 44-2383094 T: (91) 44-2385567 F: (91) 44-2385569 E: mail@vlindia.com
Latin America
Europe
Venture Lighting International 5805 Blue Lagoon Drive Suite 395 Miami, Florida 33126 USA
Venture Lighting Europe Ltd. Trinity Court Batchworth Island Church Street, Rickmansworth, WD3 1RT, United Kingdom
T: 800-451-2606 T: 440-248-3510 F: 800-451-2605 E: venturesales@adlt.com
T: 305-269-8114 F: 305-269-8727 E: vllatinamerica@adlt.com
â&#x20AC;&#x201A;62
T: (44) 0845-2302222 F: (44) 0845-2302077 E: sales@venturelighting.co.uk
Asia Pacific HID Lighting Systems Catalogue
Advanced Lighting Technologies Australia Inc.
Advanced Lighting Technologies New Zealand Ltd
Advanced Lighting Technologies Asia Pte Ltd
110 Lewis Road Wantirna South VIC. AUSTRALIA 3152
8 Boeing Place Mount Maunganui NEW ZEALAND
Block 4008, Ang Mo Kio Avenue 10 #04-06, Techplace I SINGAPORE 569625
T: 61 3 9800 5600 F: 61 3 9800 5533 E: sales@adlt.com.au
T: 64 7 579 0163 F: 64 7 579 0164 E: light@adlt.co.nz
T : 65 6844 2338 F: 65 6844 2339 E: sales@adlt.com.sg
www.adlt.com.au www.venturelighting.com.au
www.adlt.co.nz www.venturelighting.co.nz
www.adlt.com.sg www.venturelighting.com.sg
VC1013