Meet Element 2.0 Upon its introduction to the market a little over three years ago; the Element, Visionaire Lighting’s flagship LED fixture, simply took off. Now, after hundreds of Element projects have been installed around the globe, we’re taking our bestselling LED luminaire and making it even better.
What’s New? The Element II’s quality is visually apparent as soon as it is table‑topped alongside a competitor’s fixture. Enhanced areas include: • Aluminum end caps, which are die cast for strength; and enhanced with design elements for a pleasingly sophisticated look. • Additional, advanced optics that leap ahead of the competition; giving the Element II the leading edge in nearly every desired application. • More housing sizes for increased scale-ability. • Two new low-profile end mount arms designed to enhance the beauty of the Element II while adding function for higher lumen lighting applications.
Visionaire Lighting’s Evolution C Technology Is All About Performance The Element II incorporates the flexible Vision bar technology which allows for LED fixture selection from 24 LEDs all the way to 288 LEDs in 24 LED increments We at Visionaire Lighting have pioneered the highest benchmark for Solid State Lighting (SSL) technology in the industry. We call this benchmark Evolution C; and we have officially incorporated it into this release of our newest, Element II family of LED luminaires. Evo/C is the kind of comprehensive approach that only a lighting manufacturer with a decade-plus of production can advance. Evo/C is more than just the lumen output of LEDs -- it’s more than the driver -- and it’s more than the housing. Evo/C is synergy. It’s picking the best of everything; and constructing parts in-house when what is available isn’t good enough. Evo/C is hiring the smartest engineers in the business to design, build, test; then re-test until a fixture meets Visionaire’s exacting standards. Evo/C is about vertical integration within our own plant - Made in the USA.
8
6
7
PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.
D
8
5
6
7
4
3
2
C
More Tailored Mounting Options For Maximum Versatility PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.
1
8
6
7
PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF VISIONAIRE LIGHTING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF VISIONAIRE LIGHTING IS PROHIBITED.
D
D
Bolt-On Arm
Mast Arm
Wall Mount
Pendant Mount D
B
Bolt-On Arm Quick Mount
A
Mast Arm Fitter End Mount
C
C
C
A
End Mount (Side)
End Mount (Front)
Ceiling Mount
B
B 6
7
8 B
UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ± ANGULAR: ± 1 ° TWO PLACE DECIMAL THREE PLACE DECIMAL
A
NAME
19645 RANCHO WAY , RANCHO DOMINGUEZ, CA 90220
TITLE:
CHECKED ± .03 ± .015
A
ENG APPR. MFG APPR. Q.A.
INTERPRET GEOMETRIC TOLERANCING PER:
COMMENTS:
MATERIAL
SIZE
A
B
FINISH
7
6
5
4
DWG. NO.
SCALE: 1:4
DO NOT SCALE DRAWING
8
VISIONAIRE LIGHTING
DATE
DRAWN
8
Q1 SHEET 1 OF 1
WEIGHT:
2
3
REV
EL2-MA 1
7
1.
6
2.
3.
TESTED FOR LIFE
Feel the Breeze – the Venturi Effect
The secret to the Element II’s advanced efficiency is superior heat reduction.
The Venturi Effect dictates that, with increased air flow, heat transfer rates increase exponentially, removing heat at ever-faster rates.
To get there, we built a powerhouse of a heat sink, and designed it to make maximum use of the Venturi Effect.
Sinking the Heat – Successfully In LED luminaires, the most critical areas to cool are the junction points where the LEDs meet the circuit board. The heat sink is used to draw heat away from these points. The Element II’s extruded aluminum heat sink is substantial. With a maximized fin ratio and precisely-mapped channel distributions; thermal build-up peels away from the Element II’s junction points, allowing for cooler operation.
4.
Hold your hand over the Element II, and feel it — that rush of air rising up through the fixture, and out the top. Engineering for this effect cools LEDs, drivers and internal components; allowing the Element II to: • Withstand higher ambient temperatures. • Withstand higher drive currents. • Achieve a low thermal resistance rating. • Extend LED life. This effect doesn’t occur with external, decorative heat sinks -- like those found in competing products. Combining heat sink technology with the Venturi Effect produces a superior, long-lasting product with increased light output.
Element II, Size 1
Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.
Element II, Size 2
Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.
Element II, Size 3
Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.
Element II, Size 4
Drive current of 350mA yields an L70 of 150,000 hours. Drive current of 530mA yields an L70 of 100,000 hours.
Element II, Size 5
Drive current of 350mA yields an L70 of 150,000 hours.
5.
Evolution C Pioneering the Benchmark for Ultimate LED Performance Visionaire Lighting’s Evolution C benchmark of luminaires features the highest-lumen-output Light Emitting Diodes on the market, outfitted with our proprietary, cutting edge optics (patents pending). Here’s why: 1. Highest available lumens per watt for maximum efficiency. 2. Improved CRI (Color Rendering Index) for truer colors. 3. Tighter color binning for maximum Kelvin uniformity. 4. Lower forward voltages means lower system watts for increased efficiency (Lumens/Watt). 5. Longer life for 350 and 530 mA. 6. Marginal decreases in efficiency between 350 and 530 mA. The Element II’s VisionBarTM LED light assemblies come in multiples of 24 (minimum 24 to maximum 288 LEDs), and are field replaceable. No other outdoor lighting manufacturer can offer your project more efficient, cost-effective and application-specific LED lighting solutions.
6.
Superior Kelvin and CRI The Element II is offered in two highly desirable Kelvin temperatures, 4000K and 5500K. We have selected these two Kelvin temperatures as standard because 4000K matches the Kelvin of typical metal halide fixtures and 5500K yields a bluer white color which enhances car dealerships and lower wattage applications. Both Kelvins have similar lumen output. The CRI of the 4000K LEDs are 70 and the CRI of the 5500K LEDs are 75. Please consult factory for additional Kelvin temperatures which can be ordered as well as LEDs with higher CRIs. The Color Rendering Index, or CRI, is a measure of the quality of color light as the human eye sees it. Driver Power The Element II is powered by a choice of 350 or 530 mA high‑performance Constant Current Philips Advance Xitanium LED drivers, which accept 120v thru 277v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 oC operations. Expected life of the driver ranges from 100,000 to 150,000 hours. 1) The LED driver reduces output power to LEDs if its maximum allowable case temperature is exceeded. 2) The LED driver complies with UL standard UL1012. 3) The LED driver has a Class A sound rating. 4) As an option the LED drivers come dimming enabled with a 0-10 volt input. 5) The LED driver has a THD (Total Harmonic Distortion) of less than 20%.
Why Dim LEDs? Dimming LEDs save energy at an approximate 1:1 ratio. This means by dimming the LEDs to 50% of their light output, the LEDs’ energy usage will decrease by nearly 50%. Dimming LEDs also makes them run cooler, which extends the life of the driver, as well as doubling or tripling the LEDs lumen maintenance. Select the dimming type, then schedule settings and, in the case of Dual Circuit, add optional motion sensor. LED luminaires really earn their worth when controls are applied. Consider choosing one of the following options to achieve the ultimate return on your investment.
3. Event-Based Dimming (EB)
1. Analog 0 – 10 Volt
• Triggers up to 32 events. • Provides outage notifications. • Monitors energy consumption.
A pre-installed 0 - 10 volt driver enables the fixture to be operated by a separately-provided control system. 2. Dual Circuit (DC) Separate driver circuits provide two levels of light (high and low) without requiring a controller. Can be tied to an optional motion sensor.
Luminaires arrive installed with controls that are preprogrammed to trigger up to five, timed events of varying dimming percentages. See the Event-Based Dimming Example Chart below. 4. Wireless Controls (WC) Enables event-based dimming to be modified remotely after pre-programmed fixtures are installed.
Optional Motion Sensor Activity close to the luminaire triggers an event of 100% brightness lasting for several minutes. Afterwards, illumination returns to the level of the current event.
Examples: • Two drivers a 50% reduction in output. • Three drivers a 33% or 67% reduction in output.
7.
8.
Performance Starts with Optics that Outpace All Others Visionaire Lighting’s proprietary optics are the industry leader. Patent pending lens designs produced in-house simply can’t be duplicated by others. Painstakingly developed by our Photometrics team, these nine optic types give the Element II an edge; allowing us to manufacture fixtures that illuminate beautifully at lower wattages and wider pole spacings. To learn more, visit our Photometrics website section; or call us for layout assistance.
A Superior Line-up of Optics Type I
Optics
1
Type I Type 1 II 1
II
Type II
ype I
2 2
Type III
pe II 2 pe pe II II
pe III 3 III pe
3-R
Type IV 4 Type Type IV IV
3 3 2-R
3-R 3-R
IV-A
4
Type V
3-R
2-R 2-R
Type III 3 Type Type III III III
Type IV 4 Type IV IV+CLS
3
2
Type III
3-R IV
Type IV
2-R
2-R 2-R
Type II Type 2 II
Type II II-R 2
1
Type I Type II Isolux Pattern Best Application(s)
4-A
V
4-A
V-W 4+CLS 4+CLS
3
4 4 3-R
4-A 4-A 4-A
4+CLS 4+CLS 4+CLS Type V 5 Type V
2
Type III Key Feature(s) Type IV 3
4
Type V 5
• One- and two-lane roadways. Enables pole spreads at six to eight times mounting height III V • LongType pedestrian paths. Type IV to achieve Type intersection. Type Type Type 5 V 3 III aisles. 4 IV • Warehouse 3
4
3-R
4-A
3-R • Parking2-R lots. • Street-adjacent back lots.
5
4-A 5W at light levels greater Best where sideways light is required than one Footcandle. 5W
3-R and four-lane4-A Optimal for staggered 5W • Two-, threelight spacing requirements. 4+CLS roadways. Type IV Type V 5 4+CLS V • Four-Type to six-lane roadways. Designed for side light, 45o light, and forward 4+CLS • Cross walks. light applications requiring light levels of one or 5 V Type 4
Type V • Site perimeters. 5 5 4-A
• Shopping centers. • Office complexes.
more Footcandles.
5W
5W
5W 5W • Auto4+CLS dealerships.
• High-brightness inspection areas.
Effective for forward-light applications that require a half a Footcandle or more across distances. Best where a combination of high Footcandles at low wattages are required.
• LEEDs projects.
Useful for projects requiring pristine back light control and zero light trespass.
• High-clearance parking structures.
Excellent for low mounting-height installations requiring minimums of one Footcandle.
• Low-clearance parking structures. • Outdoor parking areas.
Best for 400+ wattage requirements, and retrofitting vertical lamp fixtures at typical 120x120 or 180 x180 spacings.
5
5W 5W
A = Automotive . R = Roadway . W = Wide . +CLS = with external Cutoff Louver Shield option. For additional LEEDS-qualifying shields, please consult factory.
9.
Our new Type Five optic designed for large parking lots enables 400 watt fixtures to be replaced at a lower wattage without photopic light level sacrifice with improved uniformity. Twin Element II Fixtures - End Mount EL2-4-T5W-168LC-530-4000K 275 system watts Type Five Wide distribution 120 foot by 120 foot spacing 33 foot mounting height Full cutoff
10.
Our new Type Four optic with Cutoff Louver System is designed for the most stringent light trespass criteria, cutting the light behind the luminaire to .01 foot candles at 3/4 mounting height. Single Element II Fixture - Bolt-On Arm EL2-3-T4-120LC-530-4000K-CLS 190 system watts Type Four distribution with Cutoff Louver System 60 foot spacing 25 foot mounting height Full cutoff
11.
(LIFE) Let us Find the Perfect Balance for Your Specific Application The L70 test determines the point in an LED’s life when it reaches 70 percent of its initial output. Element II series LEDs have been determined to last 150,000+ hours in 40 oC environments when driven at 350 mA. At Visionaire Lighting, we have discovered that the secret to the perfect LED fixture fit is to determine the perfect balance between number of VisionBarsTM and the milliamps to drive them at.
More Lumens per Dollar In an exceptionally well-cooled fixture like the Element II, it becomes possible to drive fewer LEDs at higher milliamps. Fewer LEDs putting out more lumens creates the right amount of light for the job, while at the same time reducing the initial cost of the luminaire.
12.
HID to LED Crossovers
Return on Investment (ROI) per single fixture retrofit. A Brilliant Performer FINANCIALLY, TOO!
Street Lighting Crossovers System Watts
HPS Life Hours
Proposed Element II Configuration
400 HPS
464
24,000
250 HPS
295
24,000
Existing Wattage
System Watts
LED L70 Life Hours
Watts Saved
Energy Saved
10 Year Energy Savings*
10 Year Maintenance Payback**
10 Year Total Savings**
EL2-3-120LC-530
190
100,000
274
59%
$1,434
$332
$1,766
EL2-1-96LC-530
152
100,000
143
48%
$750
$332
$1,082
200 HPS
250
24,000
EL2-1-72LC-530
114
100,000
136
54%
$710
$332
$1,042
150 HPS
188
24,000
EL2-1-72LC-530
114
100,000
74
39%
$380
$332
$712
100 HPS
130
24,000
EL2-1-48LC-530
76
100,000
54
41%
$270
$332
$602
70 HPS
91
24,000
EL2-1-48LC-350
56
150,000
35
38%
$170
$332
$502
*Savings calculated on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour. **Estimated cost of replacing 1 HPS lamp every 6 years, including equipment rental, parts and labor.
Parking Lot Lighting Crossovers System Watts
MH Life Hours
Proposed Element II Configuration
400 MH
458
20,000
EL2-3-144LC-530
250 MH
295
20,000
EL2-1-96LC-530
175 MH
210
15,000
EL2-1-72LC-530
100 MH
129
20,000
EL2-1-48LC-530
70 MH
90
12,000
EL2-1-48LC-350
Existing Wattage
LED L70 Life Hours
Watts Saved
Energy Saved
10 Year Energy Savings*
228
100,000
230
50%
152
100,000
143
48%
114
100,000
96
45%
76
100,000
53
41%
56
150,000
34
37%
System Watts
10 Year Maintenance Payback**
10 Year Total Savings**
$1,500
$398
$1,898
$935
$398
$1,333
$630
$398
$1,028
$350
$398
$748
$220
$398
$618
*Savings based on 12 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour. **Estimated cost of replacing 1 MH lamp every 5 years, including equipment rental, parts and labor.
Parking Garage Lighting Crossovers System Watts
MH Life Hours
Proposed Element II Configuration
System Watts
LED L70 Life Hours
Watts Saved
Energy Saved
10 Year Energy Savings*
175 MH
210
15,000
EL2-1-48LC-530
76
100,000
134
64%
175 MH
210
15,000
EL2-1-72LC-350
84
150,000
126
60%
150 MH
188
15,000
EL2-1-48LC-530
76
100,000
112
150 MH
188
15,000
EL2-1-72LC-350
84
150,000
100 MH
129
20,000
EL2-1-48LC-350
56
150,000
70 MH
90
12,000
EL2-1-24LC-530
38
100,000
Existing Wattage
10 Year Maintenance Payback**
10 Year Total Savings**
$1,769
$500
$2,269
$1,663
$500
$2,163
60%
$1,478
$500
$1,978
104
55%
$1,373
$500
$1,873
73
57%
$964
$500
$1,464
52
58%
$686
$500
$1,186
*Savings based on 24 hours of usage/night, 7 nights/week, at 12¢/kilowatt-hour. **Estimated cost of replacing 1 MH lamp every 2.5 years, including parts and labor.
13.
Area
A
E
A
Front View
C
B
Side View - EBOA
D
Side View BOLT-ON ARM
A
E
Side View - EMAF
Garage/Canopy Fixture EL2-S EL2-1 EL2-2 EL2-3 EL2-4 EL2-5
Model EL2-S Type I 1
EL2-1
Type I
Type II
Type III
Type II 2
A 14” 18” 24” 28” 32” 38”
B C 14½” 4” 14½” 4” 14½” 4” 14½” 4” 14½” 4” 14½” 4”
Optics
Source
Type II Type 1 (T1)
Type II # of LEDs 2 24 (24LC) 48Type (48LC) III 3 72 (72LC) 2-R
Type IIII Type 2 (T2)
Type II-R 2-R (T2R) Type IIIIII Type 3 (T3)
EL2-2 Type III 2-R 3
Type IV Type IV 3-R 4 (T4)
EL2-4
Type IV only *End mount 4
EL2-5
*End4-A mount only
4+CLS
14.
24 (24LC) 3-R 48 (48LC) 72 (72LC) 96Type (96LC) IV 4
120 (120LC) V 144Type (144LC) 4-A 5
E
Max. LEDs Lbs 72 30 38” 96 34 144 38 42” 28½” 144 41 192 62 32½” 288 48½” 68 n/a
Milliamps Type III 3
350 530 350 530 Type IV 4 n/a 350 3-R (3)
(5)
350 4-A 350 350 350V Type
530 530 530 530
(3)
5 4+CLS
(5)
530 530
Type V Type V 4+CLS 5 (T5)
168 (168LC) 192 (192LC)
350 530 350 530
216 (216LC) 240 (240LC) 264 (264LC) 288 (288LC)
(5)
350 350 350 350 (3)
(4K)
Type V
5500K
5 4-A
*Cool white
(55K) 5W 4+CLS
*Universal voltage
(UNV)
480 5W (5)
347 (8)
Mounting Bolt-On Arm (BOA)
Side View/End Cap
Finish White (WH)
Wall Mount (WM)
Knuckle Mount
*Slips over 2 3/8” Tenon with adjustable Increments of 10˚
(MAF)
(5)
Pendant Mount *Specify pendant Iength
(PM)
(BZ)
End Mount *Requires 2-3/8” horizontal tenon
(DIM) (PCR120) (PCR208) (PCR240) (PCR277)
Photo Receptacle (PER) *With shorting cap
Black (BK)
Button Type Photocell *Specify voltage
(PC120) (PC208) (PC240) (PC277)
Round Pole Plate Adaptor
Grey (GY)
End Mount Bolt-On (EBOA)
No Controls
*Specify voltage
Bronze
(KM)
Mast Arm Fitter
Options 0-10v Dimming Driver Photocell & Receptacle
*Includes Cast Wall Plate
(CM)
5W (3)
120 (120LC) 1444+CLS (144LC) 5W
Type V-W 5W (T5W)
A
Top View
Ceiling Mount
350 350
(3)
B
Kelvin Voltage Type V 120-277 4000K 5 4 *Neutral white
C
B
Type IV
mA
Type IV-A 4-A (T4A)
EL2-3 3-R
D 21½” 21½” 21½” 21½” 21½” 21½”
For 4ӯ Pole (RPP4) For 5ӯ Pole (RPP5)
Element Conduit Box (ECB)
Cutoff Louver System (CLS)
Silver Metallic (SL)
Vandal Resistant Shield (VRS)
Dual Circuit
(EMAF)
(DC)
Custom Color (CC)
Motion Sensor (MS)
10KV Surge Protector (10KV)
10.20.14
Housing
• The fixture housing is heavy-duty, extruded aluminum, with heat radiating fins. A perforated aluminum top cover, beneath a protective debris guard, protects the heat radiating fins from contaminants and directs constant air flow over them for maximum cooling.
Thermal Management
An internal clamping device provides a secure attachment to the mast arm, eliminating the need to drill for thru-bolt attachment. •EBOA- End Mount version utilizing the same Quick Mount pole adaptor for a bolt-on application •EMAF- End Mount Mast Arm Fitter is provided with a cast aluminum arm adaptor designed to slip fit over a 2” horizontal tenon (mast arm) and is fully adjustable.
• The Element II provides excellent overall thermal management by maximizing the fixture’s heat sink efficiency. This enables the Element II to withstand higher ambient temperatures and drive currents without degrading LED life. The Element II has a low thermal resistance rating. The heat radiating fins and perforated fixture components create superior thermal management results. • The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. Element II series LEDs have been determined to last 150,000+ hours in 40 oC environments when driven at 350 mA. See LED Data Chart for additional test results.
A round pole plate adaptor is required for mounting to a 3”- 6” round pole.
Optical System
• Steel ceiling mount bracket can be secured directly to recessed junction box, or to the ceiling. The housing hanger bracket allows fixture to be suspended from ceiling bracket while making wiring connection. The housing bracket then attaches to the ceiling bracket via a tool-less latch. A tamper-proof screw can then secure the bracket.
• The highest lumen output LEDs available are utilized in the Element II series. IES Types III and V distributions are standard. The LED VisionBarTM light assemblies come in multiples of 24 (minimum 24 to maximum 288 LEDs) and are field replaceable. The optical system qualifies as IES full cutoff; and is Dark-Sky certified to restrict light trespass, glare and light pollution.
Quali-Guard Finish ®
• A Quali-Guard® thermoset polyester powder coat painted finish is available in white and custom colors.
Mounting - Area
•BOA- The cast aluminum Bolt-on Arm is shipped mounted to the fixture. A pole plate is supplied for mounting to the pole; which allows for quick and easy fixture installation with two set screws. •WM- Galvanized steel wall mount bracket can be secured directly to recessed junction box or the wall. The fixture is supplied with a shortened arm bracket to keep the fixture closer to the wall. •CM- Steel ceiling mount bracket can be secured directly to recessed junction box, or to the ceiling. The housing hanger bracket allows fixture to be suspended from ceiling bracket while making wiring connection. The housing bracket then attaches to the ceiling bracket via a tool-less latch. A tamper-proof screw 05.09.11 ~ Added 3 “n/a”s to ELE-2. can then secure the bracket. •KM- Knuckle Mount will mount over a 2” horizontal or vertical tenon and is field adjustable in increments of 5° •MAF- Mast arm fitter is provided with a cast aluminum arm adaptor designed to slip fit over a 1¼” to 2” horizontal tenon (mast arm) and is adjustable +/- 5 degrees for fixture leveling.
Mounting - Roadway
• The Element II - Roadway is provided with a cast aluminum arm adaptor designed to slip fit over a 1¼” to 2” horizontal tenon (mast arm) and is adjustable +/- 5 degrees for fixture leveling. An internal clamping device provides a secure attachment to the mast arm, eliminating the need to drill for thru-bolt attachment.
Mounting - Garage/Canopy
Electrical Assembly
• The Element II is supplied with a choice of 350 or 530 mA high‑performance LED drivers that accept 120 v thru 277 v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40 oC operations.
Warranty
• Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit VisionaireLighting.com.
Options
• 0-10v Dimming Driver • Photocell & receptacle • Cutoff louver system • Photo receptacle • Vandal-resistant shield • Button type photocell • Dual circuit • Round pole plate adaptor • Motion sensor • Element conduit box Please consult factory for custom options and available upgrades
Listings • Element II is ETL listed, suitable for wet locations. • LM79 and LM80. • IP65 Listed. • Meets ANSI C136.31-2001 Vibration Standards at 2G when ordered with the MAF mounting option. • RoHS compliant. • Powder Coated ToughTM .
EPA Data Data EPA Fixture with Arm EL2-S
.6
.8
1.3
1.1
1.1
1.1
EL2-1
.7
.9
1.3
1.2
1.2
1.2
EL2-2
.8
1.0
1.3
1.4
1.4
1.4
EL2-3
.9
1.2
1.3
1.5
1.5
1.5
EL2-4
1.2
1.6
2.4
2.6
2.6
2.7
EL2-5
1.3
1.7
2.3
2.7
2.6
2.7
End Mount Only
End Mount Only
15.
LED Data Chart LED Data Chart for 5500K* Output mA
Initial Lumens Type 1
Initial Lumens Type 2
Initial Lumens Type 2R
Initial Lumens Type 3
Initial Lumens Type 4
Initial Lumens Type 4A
Initial Lumens Type 5
Initial Lumens Type 5W
System Watts 120-277
L70 Hours @ 40째 C
350
2263
2362
2226
2250
2262
2352
2375
2380
28
150,000
530
2520
2841
2470
2776
2684
2691
3030
3047
38
100,000
350
4526
4724
4452
4501
4525
4704
4750
4760
56
150,000
530
5042
5683
4940
5553
5368
5382
6087
6094
76
100,000
350
6789
7086
6678
6483
6786
7056
7125
7140
84
150,000
530
7563
8524
7410
8330
8052
8073
9128
9141
114
100,000
350
9052
9448
8904
8645
9048
9408
9500
9520
112
150,000
530
9923
11365
9880
11107
10736
10764
12174
12188
152
100,000
# Bars
# LEDs
1 EL2-1
24
2 EL2-1
48
3 EL2-1
72
4 EL2-1
96
5 EL2-2
120
350
11315
11810
11130
10212
11310
11760
11875
11900
140
150,000
5 EL2-3
120
530
12405
14207
12350
13884
13440
13457
15216
15235
190
100,000
6 EL2-2
144
350
13588
14172
13356
12255
13572
14112
14250
14280
168
150,000
6 EL2-3
144
530
14885
17048
14820
15260
16128
16146
18260
18816
228
100,000
7 EL2-4
168
350
15841
16534
15582
14297
15834
16464
16625
16640
196
150,000
530
17367
19890
17290
17803
18788
18837
19418
21818
266
100,000
8 EL2-4
192
350
18105
18896
17808
16341
18096
18816
19000
19040
224
150,000
530
19847
22780
19760
20000
21472
21528
22191
24366
304
100,000
9 EL2-5
216
350
20367
21258
20034
20560
20358
20168
21004
21420
252
150,000
10 EL2-5
240
350
22630
23620
22260
22600
22620
23520
23008
23800
280
150,000
11 EL2-5
264
350
24893
25982
24486
24640
24882
25872
25012
26180
308
150,000
12 EL2-5
288
350
27176
28344
26712
26680
27144
28224
27016
28560
336
150,000
Visit www.VisionaireLighting.com for up-to-the-minute chart information, including types not listed here. * For 4000K multiply values by 0.90 03.07.12
16.
A Product That’s Road Tested
ETL Certified The ETL Listed Mark is proof of product compliance to North American safety standards. Authorities Having Jurisdiction (AHJ’s) in 50 states and Canada and retailers accept the ETL Listed Mark as proof of product safety. Safety standard test practices conform to UL, ANSI, CSA, ASTM, NFPA, and NOM.
IP65 Rated As defined in international standard IEC 60529, IP Code classifies and rates the degrees of protection provided against the intrusion of solid objects, dust, accidental contact, and water in mechanical casings and with electrical enclosures.
RoHS Certified The RoHS directive aims to restrict certain dangerous substances commonly used in electronic equipment. Any RoHS compliant component must have 100ppm or less of mercury.
ANSI Certified The Element II is ANSI C136.31-2001 certified for luminaire vibration at 2G.
17.