Brochure 2013 vlx led sml

Page 1



VLX - LED Luminaire The new VLX LED Series offers clean, functional styling that is defined by its sleek low profile design and rugged construction. It combines the latest LED performance and advanced LED thermal management technology, and provides lighting that is both energy efficient and aesthetically pleasing. Choose from 64 to 192 LEDs in one fixture size, that looks perfect with any of the LED configurations; thereby enabling the lighting designer to tailor the lighting to the application needs; while maintaining a uniform appearance throughout the entire project. Choose from a 7,000+ lumen package with life expectancy of well over 20 years; or 46,000+ lumens for your higher wattage needs. Consider Visionaire’s new “Vision-Net” dimming control system for affordable wireless control of your LED lighting system; for even more energy savings. For general parking, pedestrian areas, and roadways; the VLX LED series brings contemporary LED lighting design into the 21st century. Fixture Construction • Die-cast aluminum housing with integrated heat sink for maximum thermal management of the LEDs for extreme long life of the LEDs. • Two piece, tool-less entry, die-cast mounting arm and driver compartment for ease of mounting, and driver maintenance. • A pole mounting design that simplifies the installation of the fixture. • Engineered optical assemblies with six distribution patterns. LED Technology • 64 to 192 LEDs • 350,530,700 or 1000 mA ratings. • 9,000 to 46,000+ lumen package available. • 4000 or 5000 Kelvin for natural or white light. • Full cutoff optics available in six distribution patterns. • 69,000 to 126,000 hours or more of life for the LEDs • Add dimming controls for increased cost savings and project flexibility. Applications • The VLX LED Series is destined to become the standard for which LED area lights are measured. Simple flowing lines that house scalable LEDs that replace traditional HID fixtures; for a wide range of lighting applications. From shopping centers to auto dealerships; to general parking lots to roadways; the VLX LED series is the transition of LED lighting into tomorrow.




Die Cast Aluminum Integral Heat Sink

Built to draw heat away from the LED junction points for extended LED life.

LED Light Engines

The LED light assemblies come in multiples of 32 (minimum 64 to maximum off 192 LEDs) and are field replaceable.

Full Cutoff Optics

Available in six different distribution patterns.

LED Driver(s)

High performance with a power factor greater than 90%, and rated for -40째 C operation. Supplied with quick disconnects for ease of service.

Terminal Block

For easy power connection. Maximum 8 gauge wire.

Surge Protector

10 kV Surge protector supplied as standard.

Die Cast Aluminum One Piece Removable Door With One - Piece Gasket For complete weather protection.

Easy Access Tool-less Entry

Push button access to the driver compartment.


Die Cast Aluminum Driver Compartment

Separated from the LED array/heat sink structure; and provides easy driver access.

Safety Cable

To limit door movement.

Die Cast Aluminum Quick Mount Pole Cleat Assembly For ease of mounting




Project Name:

VLX LED

Catalog Number:

Type

Dimensional Drawings

C

D B A

The new VLX LED Series offers clean, functional styling that is defined by its sleek low profile design and rugged construction. It combines LED performance and advanced LED thermal management technology and provides outdoor lighting that is both energy efficient and aesthetically pleasing.

Fixture

A

B

C

D

Max. Watts

Lbs

VLX-1

36”

4”

15.5”

4”

414

58

The LED light assemblies come with 64 to 192 LEDs. Six optical distribution patterns are available. Choose between 4000 or 5000 Kelvin temperature of the LEDs. A durable polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors.

The LED’s performance and the driver’s life are maximized by enclosing them in two separate die cast aluminum housings. The VLX LED series is an exceptional choice for commercial parking lots, office complexes, architectural projects, and Easy tool-less access for mounting and maintenance. other general lighting projects.

Model

Optics

VLX-1

Type II (T2)

Type III (T3)

Type IV (T4)

Type IV-A (T4A) Type IV-AR (T4AR) Rotated Right

Type IV-AL (T4AL)

Source Current # of LEDs mA 64 350 (64LC)

(3)

96

530

(96LC)

128*

(128LC)

160*

(160LC)

(5)

700 (7)

1000* (10)

Kelvin 4000K

*Neutral white

(4K)

5000K

*Cool white

(5K)

Voltage 120-277

Mounting Arm Mount (AM)

*Universal voltage

(UNV)

480

Finish Bronze (BZ)

Wall Mount

*Cast Wall Plate (BAWP) to be ordered separately

(WM)

(5)

Not available in 1 amp

Not available in 1 amp

(PCR208) (PCR277)

Smooth Black

Round Pole Plate Adaptor For 3ӯ Pole (RPP3) For 4ӯ Pole (RPP4) For 5ӯ Pole (RPP5) Cast Wall Plate (BAWP)

(WH)

(8)

*Specify voltage

(PCR120) (PCR240)

Photo Receptacle (PER)

White

347

Photocell & Receptacle

(BK)

(SBK)

Smooth White (SWH)

*With shorting cap

0-10v Dimming Driver No Controls

(DIM)

Motion Sensor

192*

Graphite

(192LC)

(GP)

*Works with FSP-211

(WSC-8)

8’ Mounting Height

(WSC-20)

9-20’ Mounting Height

Grey

VLX DRILL DIAGRAM

Rotated Left

(GY)

C L

2 1/2’’

Type V (T5)

Ø 3/8’’ Ø 1’’

1’’

Ø 3/8’’

1’’

Type V-W (T5W)

Black

Options

Silver Metallic (SL)

Custom Color

(WSC-40)

21-40’ Mounting Height

Wireless Control Consult Factory

(WC)

Universal Pole Mount Adaptor (UPMA)

(CC)

*1000 mA NOT AVAILABLE FOR 128LC, 160LC OR 192LC

Round Pole Plate Adaptors (RPP) are to be ordered separately.

For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice.


VLX Housing • Die cast aluminum LED housing with integral cooling fins for thermal management. Mounting Arm/Driver Compartment •Durable two-piece die cast aluminum driver compartment utilizes a tool-less push button latch for ease of maintenance and sealed with a one-piece silicone gasket. Thermal Management • The VLX series provides excellent thermal management by mounting the LEDs to the substantial heat sink of the housing. This enables the Luminaire to withstand higher ambient temperatures and driver currents without degrading LED life. • The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. The VLX series LEDs have been determined to last 100,000+ hours in 25° C environments when driven at 350 mA. Optical System • The highest lumen output, Evo/C LEDs are utilized in the VLX series. IES distribution Types II, III, IV, IV-A , V and V-W are available. The optical system qualifies as IES full cutoff to restrict light trespass, glare and light pollution. • CRI values are 70 for 4000K and 75 for 5000K. Quali-Guard® Finish • The finish is a Quali-Guard® textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400º F to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors. • Finish is guaranteed for five (5) years.

LED

Electrical Assembly • The VLX LED series is supplied with a choice of 350, 530, 700 or 1000 mA high-performance LED drivers that accept 120v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations. • 10 kV surge protector supplied as standard. • Terminal block supplied as standard. Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, please visit visionairelighting.com. Options • Photocell & receptacle • Photo receptacle • Round pole plate adapter • Cast Wall Plate • 0-10v Dimming Driver • Motion Sensor • Wireless Control •Universal Pole Mount Adaptor Listings • The VLX is ETL listed, suitable for wet locations. • IP65 Rated • Powder Coated Tough. • DLC Listed

IP65

RATED

DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/

VLX 5K LUMEN DATA # LED’s

mA

TYPE 1

B

U

G

TYPE 2

B

U

G

TYPE 3

B

U

G

TYPE 4

B

U

G

TYPE 4A

B

U

G

TYPE 5

B

U

G

TYPE 5W

B

U

G

64

350

9655

3

1

3

9015

2

1

2

9160

2

0

2

8634

1

1

2

9680

1

1

1

9388

3

0

1

9178

3

0

1

71

530

13382

3

1

3

12495

2

2

3

12695

2

0

2

11967

2

1

2

13416

2

1

2

13011

3

0

1

12720

3

0

2

103

96

128

160

192

WATTS

700

16940

3

2

3

15817

3

2

3

16070

3

0

3

15148

3

2

3

16983

2

2

2

16470

3

0

2

16101

4

0

2

139

1000

21683

3

2

3

20245

3

2

3

20569

3

0

3

19389

3

2

3

21738

2

2

2

21081

4

0

2

20610

4

0

2

217

350

14448

3

2

3

13491

3

2

3

13707

2

1

2

12920

2

2

2

14486

2

2

2

14048

3

0

1

13734

3

0

2

108

530

20125

3

2

3

18791

3

2

3

19091

3

2

3

17996

3

2

3

20176

2

2

2

19567

4

0

2

19129

4

0

2

163

700

25801

4

2

4

24090

3

2

4

24476

3

2

3

23072

3

2

3

25867

2

2

3

25085

4

0

2

24524

4

0

2

215

1000

33033

4

2

4

30843

3

2

4

31337

3

2

3

29539

3

2

3

33118

3

2

3

32117

5

0

2

31399

5

0

3

328

350

18101

3

2

3

16901

3

2

3

17172

2

0

2

16187

2

2

3

18148

2

2

2

17599

3

0

2

17209

4

0

2

138

530

24772

4

2

4

23130

3

2

3

23500

3

0

3

22152

3

2

3

24836

2

2

2

24085

4

0

2

23547

4

0

2

203

700

30965

4

2

4

28913

3

2

4

29375

3

0

3

27690

3

2

3

31045

3

2

3

30107

4

0

2

29433

4

0

2

268

350

21944

3

2

3

20490

3

2

3

20818

3

0

3

19623

3

2

3

22001

2

2

2

21336

4

0

2

20859

4

0

2

168 254

530

30268

4

2

4

28262

3

2

4

28714

3

0

3

27067

3

2

3

30346

3

2

3

29429

5

0

2

23547

4

0

2

700

37835

4

2

4

35327

4

2

4

35893

3

0

3

33833

3

2

4

37932

3

2

3

36786

5

0

2

35964

5

0

3

336

350

25546

4

2

4

23853

3

2

4

24235

3

0

3

22844

3

2

3

25612

3

2

3

24838

4

0

2

24282

4

0

2

202

530

36229

4

2

4

33828

4

2

4

34369

3

0

3

32397

3

2

4

36322

3

2

3

35225

5

0

2

34437

5

0

3

306

700

46448

5

2

4

43369

4

2

5

44063

3

0

3

41535

3

2

4

46567

3

2

3

45160

5

0

2

44150

5

0

3

414

Visit www.VisionaireLighting.com for up-to-the-minute chart information, including types not listed here. *For 4000K multiply values by 0.95

EPA Data 1.0

07.21.15

1.6

2.0

2.5

2.4

2.5

19645 Rancho Way Rancho Dominguez, CA 90220 Tel: (310) 512-6480 Fax: (310) 512-6486 www.visionairelighting.com


L70 DATA

The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. The VLX™ series LED’s have been determined to last 100,000+ hours in 25° C environments when driven at 350 mA.

LED Count

Drive Current (mA)

L70 (H)

64

350 530 700 1000

126,000 90,000 81,000 76,500

LED Count

Drive Current (mA)

96

350 530 700 1000

L70 (H)

121,000 90,000 80,100 75,600

LED Count

Drive Current (mA)

128

350 530 700

L70 (H)

117,000 81,000 73,800

LED Count

Drive Current (mA)

160

350 530 700

L70 (H)

112,500 78,300 71,100

LED Count

Drive Current (mA)

192

350 530 700

L70 (H) 99,000 76,500 69,300


THERMAL MANAGEMENT

The VLX Luminaire was designed with the goal of creating a robust product to last the test of time. Thermal management is absolutely a key factor in LED design. The VLX was engineered to separate the driver housing from the heat sink to allow for air flow between the compartments.

Within the design are spacers that are die cast into the driver compartment not exposed to the elements, and allow for air flow between the heat sink and driver compartment. In keeping the compartments separate not only do we get excellent air flow, we eliminate heat between the light engine and the driver compartment.


WARNING • To avoid possible risk of shock turn off power prior to installation or maintenance preferably at circuit breaker. • Product must be installed following all NEC and local Electrical Codes. 2. Slip pole plate into top of pole and align to holes on pole making sure that pole plate is flush to inside of pole wall.

3. Attach cleat assembly to pole (leave very loose) with the (2) grade 8 alloy steel hex head cap screws (Zinc yellow-plated 3/8” - 16 thread 2” lenght) attached to cleat assembly. Door mount bracket attached to cleat assembly must be at bottom.

4. Pull electrical power leads (by others) thru wireway hole on pole. Make sure there is at least 12” of leads emerging from pole.

5. Slide luminaire arm between cleats.


6. Firmly tighten luminaire with 30 ft-lb of torque to pole with (2) grade 8 alloy steel hex head cap screws attached to cleat assembly.

7. Make all electrical connections to inside of luminaire per NEC and/or any required local electrical codes. A terminal block is supplied.

8. Attach Door to luminaire.

9. Hook door to luminaire with safety cable.

10. Push door up to luminaire and close.



Turn static files into dynamic content formats.