MC-802 Wireless WallPlate Field Evaluation

The Motorola MC-802 Wireless WallPlate is designed for multi-tenant buildings such as hotels, healthcare, apartments, and dormitory housing. The principal goal is to leverage the in-building telephone wiring to deploy Ethernet and wireless LAN networks without the effort and expense of re-wiring with structured cabling. MC802 is part of the T3 PowerBroadband product family. The T3 system combines proven VDSL with patented Adaptive Line Power to produce a truly unique, high value product. Although designed primarily for hotels, the T3 PowerBroadband system can be deployed in many multi-tenant applications. When evaluating the T3 PowerBroadband system with the MC-802 Wireless WallPlate, there are three primary features that can be demonstrated:

Better wireless LAN Hotel architecture consists of individual rooms with high RF attenuation walls, firewalls, firedoors, and reflective surfaces. These structural elements can cause havoc when attempting to survey and install a traditional enterprise AP from the hotel hallway. The MC-802 WallPlate, by contrast, is installed in the guest room – right where the guest is located. The 14dBm transmitter and high-gain custom designed antenna allow the RF signals to penetrate several rooms.

Tamper-proof, fast installation When installed in the hotel guest room, it is important that the wireless AP hide “in plain sight”. The MC-802 is not marked as a WAP, and is designed to convert a standard 70mm x 114mm RJ11 telephone jack into an Ethernet and Wireless wall plate.

Adaptive Line Power Using Adaptive Line Power, the WallPlate can be line powered over the telephone wires, up to 300m. Combined with the form factor, Adaptive Line Power truly hides the WallPlate AP. Adaptive Line Power shares an advantage with PoE – the device can be rebooted by disabling and re-enabling line power at the source. This lowers maintenance visits and eases diagnostics. This application note will provide site survey and installation guidance. For additional material and personal support, please contact Motorola PBN Customer Support at the numbers listed in the appendix.

Daran Hermans Motorola Product Manager DID +1 925 201 4510 MBL +1 925 250 1467 EML dhermans@motorola.com

Motorola, Inc

Page 1 of 12


Better Wireless LAN ...........................................................................................3 Site Survey................................................................................................................................ 3 Co-Channel Interference........................................................................................................... 4

Fast Installation, Tamper proof..........................................................................5 Install the Cross Connects ........................................................................................................ 6 Configure the Switch ................................................................................................................. 7 Install In-line filters and WallPlates ........................................................................................... 8 Monitoring the Network ........................................................................................................... 10

Motorola Contact List .......................................................................................12 Supporting documents.....................................................................................12

Motorola, Inc

Page 2 of 12


Better Wireless LAN The goal of a wireless LAN site survey is to measure the RF penetration through the building architecture, and identify the location and method of installation. With the Wireless WallPlate and Adaptive Line Power, every room is a potential installation site. Thus, the site survey can be simplified greatly to determine the average room-to-WP density.

Si t e S u r v e y Activities: Load site survey code onto a WallPlate Survey one room group

Load Site Survey code Obtain the site survey code from Motorola support. Email: pbn.support@motorola.com. The code comes with instructions to load the Site Survey code onto a T3 Switch; then push it to the WallPlate. Any Wireless WallPlate can be converted into a site survey WallPlate. Since each WallPlate stores two images, you can easily switch back to production mode.

Power the WallPlate using a 12VDC regulated power supply Site Survey code allows the WallPlate to operate without a connected T3 Switch. When running the site survey code, the WallPlate has this hard-coded configuration: Transmit level 14dBm Channel 1 SSID = “Motorola-survey� Ethernet ports disabled

Install the survey WallPlate in one room It is generally best to locate the WallPlate on the wall where it will be installed. Install the power adapter. After about 2 minutes, the WP will begin transmitting the SSID. Be certain to close the doors when doing the site surveys. Signals can bounce through the hallway and give inaccurate readings.

Motorola, Inc

Page 3 of 12


Measure the Received signal level in each adjacent room Find the room where the signal level is -90dBm. Then, add one extra room. This is the ROOMto-WP density for the entire property. In this example, the -90dBm room is the fifth room. Thus, the density will be one AP in every 5 rooms. You could also use 6 rooms without trouble. This will provide a -72dBm signal or better in each room of the hotel with little co-channel interference.

5 rooms coverage per WP

AP -48

Delta (dB)

-65

-72

17

7

-80

A P -92

-88

8

8

4

C o - C h a n n el I n t er fe r en c e With the WP installed in the site survey room, continue measuring RF signal strength in rooms across the hall on the same floor, and vertically in rooms on other floors. Note the rooms where the signal level drops to -90dBm or lower. Based on the above survey, it can be demonstrated that the WPs installed in room 100 and 117 on Channel 1 will not interfere. Rooms 100 and 107 are likely within the carrier detect range; but they are on non-overlapping channels. 5 rooms

Rm100

1

Rm110

11

-70 HALLWAY

-70

HALLWAY

6 Rm107

Motorola, Inc

-70

-70

1 Rm117

Page 4 of 12


Fast Installation, Tamper proof Activities: Install mT2 Switch in phone room Install cross connects for one room Install MC-802 WallPlate in the room Measure RF signal strength Following these steps, the complete installation can be demonstrated. Particular attention should be paid to the in-room portion of the installation. In hotel environments, it is critical to guest satisfaction to get in and out of the room as quickly as possible.

Required Motorola equipment Name: Motorola P/N: Model:

T3 PowerBroadband Switch, RoHS 558975-001-00 45225

Name: Motorola P/N: Model:

m2 Ethernet WallPlate, RoHS 549478-001-00 45101

Name: Motorola P/N: Model:

MC-802 Wireless WallPlate, RoHS 557925-001-00 45225

Name: Motorola P/N: Model:

RJ11 IN-Line filter 552689-001-00 65603

Required Third Party Equipment 1. 2. 3. 4.

Two RJ21 Male cables, single or dual ended, approx 3 meters Cross connect block (type 66, 110, Krone, etc) Spool of cross-connnect wire Ethernet cables to connect the T3 into the core network Note: Type 66 cross connect blocks can be purchased with a pre-wired RJ21 connector. This simplifies the installation considerably. Use a Male-to-Male RJ21 cable with a pre-wired 66 block. If using 110 or Krone blocks, you will need to use a single-ended Male RJ21 cable and punch down the open ends of the RJ21 cable. For demonstration, fan out and punch down the first three wire pairs. The standard color codes for the first three pairs are: White-blue White-orange White-green

Motorola, Inc

pair one pair two pair three

Page 5 of 12


I n s t al l t h e C r o s s C o n n e c t s Identify the line 1 wire pair. The recommended procedure is to begin replacing cross connects at the room termination block, moving back to the PBX termination block. The reason is simple: In most cases, the room termination blocks are marked with room numbers; whereas the PBX block is marked with cable pairs or PBX port IDs.

3

2

2 1

1. Install the Cross-Connect block on the wall 2. Connect the RJ21 cables to the T3 Switch 3. Remove and replace each line 1 wire following this procedure: • • •

Starting at the Room block, remove the “old” wire termination (leave the “old” wire attached to the PBX block until step 3) Punch down a new wire on the same termination point

2

• • •

Route the new wire to the cross connect block, punch down on the right side Mark the block with the room number Punch down a new wire pair on the left side of the block

3

• •

Route the new wire pair to the PBX block At the PBX block, remove the “old” wire termination from step 1 Remove the “old” wire and punch down the new wire on the same termination

1

Motorola, Inc

Page 6 of 12


C o n fi g u re t h e S w i t ch Default username and password Username: Password:

admin <blank>

Default IP address 192.168.1.3 Login using a serial console connection, telnet, or webUI

Basic Command set The following command set applies to ports 1, 2 and 3. If other ports are used, please substitute the port IDs where shown below. This config has one open WLAN, and both remote Ethernet ports enabled. More advanced configurations including secure WLANs and VLANS can also be demonstrated if time allows. COMMANDS USING THE CLI

SCREENS USING THE WEB UI

#SYSTEM IP CONFIGURATION ip config ip-address <ip> mask <mask> gateway <gw> ip private enable dhcp server enable

#DSL PORT COMMANDS interface dsl config port(1-3) max-down 25 max-up 10 interface dsl enable port(1-3) interface remote enable port(1-3)-(1-2)

#WIRELESS COMMANDS wifi wlan profile add “My-SSID” wifi wlan config wlan(1-3)-1 profile “My-SSID” wifi wlan enable wlan(1-3)-1 interface wireless en radio(1-3) interface wireless config radio(1-3) transmit max NOTE: Line power is not enabled until after the filters are installed in the room

Motorola, Inc

Page 7 of 12


I n s t all I n - l i n e f il t e r s a n d W a l l P l at e s The Wireless WallPlate has a built-in POTS and Line Power filter for the desk phone. Install an in-line filter on all other phone jacks that will have a phone connected. The terminated filter has a clipped RJ11 connector. This is purposely done to comply with EN60950 requirements. Use a small flat blade screwdriver to lift the tab if attempting to remove the filter. If installing a filter on a bathroom phone, use the Unterminated filter. Remove the bathroom wall plate and terminate the filter in the wall box using wire beans. In-Line Terminated Filter

In-Line Unterminated Filter

Install the WallPlate Step 1 Loosen screws on wall plate approximately 6mm (1/4�) Attach the Mounting Adapter using the keyhole slots Tighten screws until the bracket is firmly attached, do not over tighten

Step 2 Connect 5cm cable (supplied) between MC-802 bottom mounted RJ11 and existing RJ11 jack.

Step 3 Attach the MC-802 to the Mounting Adapter using the supplied 6/32 thread forming screws

Motorola, Inc

Page 8 of 12


Step 4 Connect the analog phone to the RJ11 phone jack

Enable Line Power Line power should be enabled after the filters and WallPlate have been installed. Line power is safe for use with telephony equipment; but it will ring the phones if the filters are not installed first. Cmd:

interface dsl power enable port(1-3)

From the Switch CLI, check the status of the WallPlate using “show interface dsl status” • • •

READY LED will be ON when power is supplied STATUS LED will flash with WLAN traffic LINK LED will flash fast during link training, flash slow when not training, and will be solid when the VDSL link is established

Motorola, Inc

Page 9 of 12


M o n i t o r i n g t h e N et w o r k Following the above steps is useful in demonstration or evaluation of the installation and RF signal propagation. During installation, and follow-up evaluation, the system should be monitored to check for network and client status. This can be done via the CLI or webUI.

Monitoring Via the CLI These CLI commands are used to monitor the network and clients: show interface dsl status pay attention to the SNR Margin number. It should always be 6dB or above pay attention to the Quality parameter. This measures bit errors show interface wireless status if the WLANs and radios are configured correctly, the radios operational status will show “up” show wifi client statistics This command displays a top level view of the connected wireless clients. To display details, enter the client MAC address and its connected radio. The webUI is much easier to use when monitoring connected clients

Monitoring Via the webUI The webUI is much easier to use when monitoring wireless client statistics. Monitor Tab – Status This screen displays a color-coded map of every dsl and Ethernet port the dsl line status and remote Ethernet port status. Click the + sign next to the port to display additional line parameters. Pay close attention to these important parameters: Quality Quality is a measure of bit errors. If the quality becomes ‘fair’, check the SNR Margin. SNR Margin Margin is directly related to quality. Margin should always be 6dB or greater. If Quality shows fair, raise the SNR Margin target to 9dB or lower the target line rate in the Interface Tab - DSL

Motorola, Inc

Page 10 of 12


Monitor Tab – Wifi –Radio A radio can be Operationally UP only when it has a valid WLAN configuration and it is manageable by the T3. Use this screen to quickly identify the operational status and parameters of all the radios. If a radio does not appear in this list; check: • for the radio to be enabled o Interface Tab - Wireless • for an IP address from the T3 o Monitor Tab – DHCP • for a valid WLAN configuration o Wifi Tab – Profiles o Wifi Tab – WLAN Monitor Tab – Wifi – Client The highlevel information is presented for all connected wireless clients: • • • •

MAC Address Radio WLAN SSID

For further details e.g. the VLAN ID and average RSSI, click the + sign to expand the client details.

Motorola, Inc

Page 11 of 12


Motorola Contact List The following contact list should be used during the field evaluation. Copy pbn.support@motorola.com on all emails. Primary Support

pbn.support@motorola.com 925-201-4500

Lead Support

Erin Bulloch ebulloch@motorola.com Desk: 925-201-4513 Mobile: 925-548-6699

Secondary Support

John Williams Jwilliams@motorola.com Desk: 925-201-4516 Mobile: 510-331-4912 Jackson Yip jyip@motorola.com Desk: 925-201-4541 Mobile: 650-787-8753

Product Manager

Daran Hermans dhermans@motorola.com Desk: 925-201-4510 Mobile: 925-250-1467 Skype: dg_hermans