Usage category 1 - building sections: offices and industrial buildings, sections for day time occupancy, where occupying people are familiar with escape routes from the building sections.
If the building section is used as a warehouse or industrial building with area of more than 2000m² it has to have an automatic alarm system. If these building sections have a high fire load, they must have automatic sprinkler systems if the floor area is more than 2,000 m². Compulsory hose reels if the area of the warehouse/industrial building is more than 1000 m². Fire hose reels shall be placed in such a way that the distance from any given point to the nearest hose reel does not exceed 25 m taking into account the placement of room division, machines, fixed furniture etc.Rooms with a floor area greater than 1,000 m² must incorporate an automatic fire ventilation system or an automatic sprinkler system. If the building is fitted with an automatic fire alarm system or an automatic sprinkler system, it must activate the warning system which will transfer the alarm to the emergency system. Wall covering - Claddings class K1 10 B-s1,d0 [class 1 cladding] An external wall made of class B- s1,d0 materials only (class A materials) fulfils the requirements. Buildings in 1 storey with fire compartments up to 1.000 m2: Cladding class K1 10 D-s2,d2 [class 2 cladding] Ceiling covering - Claddings class K1 10 B-s1,d0 [class 1 cladding] Cladding class K1 10 D-s2,d2 [class 2 cladding] Buildings in 1 storey with fire compartments up to 1.000 m2 Cladding class K1 10 D-s2,d2 [class 2 cladding]
R 60/ REI 120
R
R 60/ R 120
R
R 30/ R 60
R
R
Escape route
R 30/ REI 60 EI 60/ EI 60 REI 60/ REI 60
R
EI 2 30 C
Escape route
R
EI 2 60 C
R
Rescue opening Hose reel
R
R
R
R
R
UNIVERSITY COLLEGE SCHOOL OF TECHNOLOGY AND BUSINESS - HORSENS PROJECT: Sletten 41, Holstebro
DATE: 09/16/11
SUBJECT: Fire analysis
SCALE: As indicated CLASS: CAHS 31
DRAWN BY: Agnieszka Machalska
PRODUCED BY AN AUTODESK STUDENT PRODUCT
R
AN-11(350)001
PRODUCED BY AN AUTODESK STUDENT PRODUCT
PRODUCED BY AN AUTODESK STUDENT PRODUCT
A fire-resisting occupied unit must have rescue opening unless providing 2 independent escape routes. The distance from any point in the room to the exit to escape route must be no more than 25m. The number of rescue openings must be appropriate for the number of people in the room.
2
R 30/ R 60 R 30/ REI 60 EI 60 REI 60 R60/ REI120 EI 2 30 C B roof (t2) R60
UNIVERSITY COLLEGE SCHOOL OF TECHNOLOGY AND BUSINESS - HORSENS PROJECT: Sletten 41, Holstebro
DATE: 09/28/11
SUBJECT: Cross section fire
SCALE: As indicated CLASS: CAHS31
DRAWN BY: Agnieszka Machalska
AN-11(350)2