Aspire Mobile Air Chair

Page 1

MOBILE AIR CHAIR A new era in mobile pressure management aspire for... Comfort Support Relief

S.W.L 180kg World’s leading high stretch, durable and breathable healthcare fabric

Integrated Postural Support Adjustable Pressure Relief Seating Generous Tilt and Recline for a “True Bed Feel”

www.aspirecare.com.au 1300 133 120


DVA Contracted

MOBILE AIR CHAIR

CLINICAL CONSIDERATIONS

Mobile Air Chair is registered in the ARTG, AUST R ARTG 281678

AS / NZS Approved

The Aspire Mobile Air Chair’s unique design promotes skin immersion and envelopment. Pressure on the skin’s surface is re-distributed, reducing the risk of pressure injury associated with prolonged sitting or lying. Ideal for clinical and aged care environments, Genuine Dartex® Fabric Surface and our modular pressure relief system maximise comfort while integrated postural contours support optimal positioning. The ergonomic and practical design make it safe and easy to manoeuvre and maintain.

ADJUSTABLE FOAM MATRIX A matrix of air flow chambers promotes skin microclimate and evenly redistributes pressure. A higher-density outer perimeter improves midline sitting, while foam cores are movable for customised positioning

OPTIMAL POSITIONING AND POSTURE • Gentle contouring in the sacral region assists the user in achieving and maintaining optimal positioning and a midline posture • In the backrest, a higher-density foam outer perimeter improves midline sitting, while foam cores are movable for customised positioning needs • Swing-away backrest wings and armrests decrease the demands on carers when transferring and positioning the user

positioning to facilitate fatigue management and relaxed positioning

FATIGUE MANAGEMENT • Integrated tilt, recline and leg raise allow the Aspire Mobile Air Chair to achieve bed-like

REMOVABLE COVERS • The cover is easily removed to facilitate laundering or replacement and for compliance with infection control requirements

OEDEMA MANAGEMENT • The generous 90° leg raise angle assists with the management of lower limb oedema SAFE HANDLING • Ergonomic grip handles assist with leverage, while a directional locking castor makes manoeuvring in a straight line through long corridors easy and safe

PRESSURE INJURY MANAGEMENT Seat • Pressure injury management and prevention is the cornerstone of the Aspire Mobile Air Chair’s design • Figure 1.1 & 1.2 show the pressure mapping performance of the Aspire Mobile Air Chair vs another leading product (50kg Female mapped)

PATIENT SURFACE ADJUSTABLE PRESSURE Contoured air bladder in the seating surface can be easily inflated and adjusted with integrated hand pump - stowed and concealed behind head wing when not in use

ERGONOMIC ATTENDANT GRIP HANDLES Control levers for tilt & recline, push handle for attendant use GAS ASSISTED TILT 250, RECLINE 500 AND LEG RAISE 900 Allows the chair to be easily transformed into a bed-like position, or set to manage posture, pressure and lower limb oedema

• OPTIONAL ACCESSORIES Tray Table CHP198861

YEAR WARRANTY

YEAR WARRANTY

Frame

www.aspirecare.com.au

|

1300 133 120

1

0

0

2

12

12

7

7

7

10

3

0

0

0

8

0

0

0

8

32

30

24

20

26

49

32

23

0

0

0

0

0

0

2

23

27

51

58

35

46

51

38

39

17

0

0

0

0

0

0

22

41

50

58

36

50

34

45

35

29

0

0

0

0

0

11

32

50

41

43

39

37

36

44

36

25

8

0

0

0

0

18

37

57

50

38

33

46

29

49

67

33

9

0

0

0

0

18

38

43

36

36

18

21

31

53

33

40

15

0

0

0

0

23

30

35

37

30

1

13

31

28

24

19

15

0

0

0

1

35

36

43

34

28

0

4

26

35

44

36

17

0

0

0

0

36

44

47

35

12

0

0

20

28

30

35

14

0

0

0

0

40

43

45

36

19

0

1

24

29

43

41

12

0

0

0

0

32

45

37

39

30

0

11

39

34

48

34

7

0

0

0

0

23

35

48

49

28

0

18

40

42

42

29

0

0

0

0

0

18

55

47

43

20

0

14

38

51

49

24

0

0

0

0

0

11

41

52

40

8

0

8

39

50

32

14

0

0

0

0

0

6

45

50

37

3

0

4

39

52

40

9

0

0

0

IMMERSION & ENVELOPMENT •

1

0

High Pressure

0

1

0

0

2

12

12

7

8

7

10

2

0

0

0

8

0

0

0

8

30

32

22

22

22

49

27

23

1

0

0

0

190 180 170 150 140 130 120

Medium Pressure

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

67.44

80

Average (mmHg)

20.54

70

Variance (mmHg²)

355.42

60

Standard deviation (mmHg)

18.85

50

Coefficient of variation (%)

91.79

40

Horizontal center (in)

8.61

30

Vertical center (in)

8.74

Sensing area (in²)

320.89

20

Regional distribution (%)

100.00

No Pressure

200 190 180

Lumbosacral contouring intelligently accommodates the gluteal shelf, allowing users to sit right back into the upholstery for improved positioning and immersion 0

2

25

23

58

60

37

49

51

41

39

18

0

0

0

170

0

0

0

23

47

50

60

39

42

34

39

32

26

2

0

0

160

0

0

11

33

49

40

40

40

37

38

50

31

23

8

0

0

0

0

17

39

57

44

42

33

42

34

40

70

35

9

0

0

130

0

0

17

31

43

35

34

18

21

34

50

35

44

14

0

0

120

0

0

21

30

37

38

30

2

12

32

26

24

17

13

0

0

0

0

35

35

44

34

30

0

4

26

36

42

40

16

0

0

0

0

37

45

43

34

11

0

0

19

29

34

33

14

0

0

150 140

Designed with Dartex PU Fabric to maximise skin Immersion (Figure 1.3) and Envelopment (Figure 1.4) which is fundamental for a support surface to effectively redistribute pressure improving blood flow which promotes healing 0

0

40

39

43

36

18

0

2

22

32

43

38

13

0

0

0

0

32

42

37

43

28

0

12

37

40

43

32

9

0

0

FIGURE 1.3 0

22

34

50

48

27

0

18

40

39

42

32

0

0

0

0

0

17

53

47

44

20

0

14

38

47

45

25

0

0

0

0

0

10

40

48

41

9

0

9

39

47

36

15

0

0

0

0

0

6

43

52

37

3

0

4

41

48

38

9

0

0

0

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

70.26

80

Average (mmHg)

20.39

70

Variance (mmHg²)

350.55

60

18.72

50

91.81

40

8.61

30

Vertical center (in)

8.76

Sensing area (in²)

320.89

20

Regional distribution (%)

100.00

Standard deviation (mmHg) Coefficient of variation (%) Horizontal center (in)

FIGURE 1.4

5

10 0 mmHg

Front directional castor improves the ability to manoeuvre in a straight line through corridors, making it safer and lighter for attendant use

www.aspirecare.com.au

0

mmHg

LOCKABLE CASTORS WITH DIRECTIONAL CONTROL

Fabric

10

mmHg

0

0

Padded Footrest CHP198860 (Pictured)

200

160

mmHg

SWING AWAY BACKREST WINGS & ARMRESTS Allows for easy patient side transfers

3

FIGURE 1.1 - ASPIRE MOBILE AIR CHAIR FIGURE Female 1.58m x 45kg - October 30, 2016 1.2 - A LEADING PRODUCT

|

1300 133 120

6

200

0

1

0

0

2

11

11

8

7

9

9

3

0

0

0

9

0

0

0

8

32

29

27

20

24

49

28

23

1

0

0

0

0

0

2

25

26

55

60

37

46

53

40

37

20

0

0

0

170

0

0

0

22

47

53

58

34

45

36

45

31

29

2

0

0

160

0

0

11

33

49

40

38

42

41

35

47

37

25

8

0

0

0

0

18

42

68

52

41

31

42

29

42

57

35

10

0

0

130

0

0

20

35

45

42

34

19

22

30

45

33

44

15

0

0

120

0

0

22

35

33

36

32

1

12

35

27

25

20

15

0

0

0

0

35

33

39

34

29

0

4

26

33

42

38

17

0

0

0

0

36

41

45

34

11

0

0

20

27

32

32

12

0

0

0

0

38

41

47

38

19

0

1

24

30

45

35

12

0

0

0

0

32

42

38

37

28

0

11

37

38

50

32

7

0

0

0

0

23

35

46

48

27

0

18

37

38

47

32

0

0

0

0

0

17

54

46

44

20

0

14

40

50

45

24

0

0

0

0

0

10

40

49

39

8

0

9

32

49

34

15

0

0

0

190 180

150 140

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

68.36

80

Average (mmHg)

20.43

70

Variance (mmHg²)

350.02

60

Standard deviation (mmHg)

18.71

50

Coefficient of variation (%)

91.56

40

Horizontal center (in)

8.59

30

Vertical center (in)

8.80

Sensing area (in²)

320.89

20


CLINICAL CONSIDERATIONS OPTIMAL POSITIONING AND POSTURE • Gentle contouring in the sacral region assists the user in achieving and maintaining optimal positioning and a midline posture • In the backrest, a higher-density foam outer perimeter improves midline sitting, while foam cores are movable for customised positioning needs • Swing-away backrest wings and armrests decrease the demands on carers when transferring and positioning the user

positioning to facilitate fatigue management and relaxed positioning

FATIGUE MANAGEMENT • Integrated tilt, recline and leg raise allow the Aspire Mobile Air Chair to achieve bed-like

REMOVABLE COVERS • The cover is easily removed to facilitate laundering or replacement and for compliance with infection control requirements

OEDEMA MANAGEMENT • The generous 90° leg raise angle assists with the management of lower limb oedema SAFE HANDLING • Ergonomic grip handles assist with leverage, while a directional locking castor makes manoeuvring in a straight line through long corridors easy and safe

PRESSURE INJURY MANAGEMENT Seat • Pressure injury management and prevention is the cornerstone of the Aspire Mobile Air Chair’s design • Figure 1.1 & 1.2 show the pressure mapping performance of the Aspire Mobile Air Chair vs another leading product (50kg Female mapped)

FIGURE 1.1 - ASPIRE MOBILE AIR CHAIR FIGURE Female 1.58m x 45kg - October 30, 2016 1.2 - A LEADING PRODUCT 0

1

0

0

2

12

12

7

7

7

10

3

0

0

0

8

0

0

0

8

32

30

24

20

26

49

32

23

0

0

0

0

0

0

2

23

27

51

58

35

46

51

38

39

17

0

0

0

0

0

0

22

41

50

58

36

50

34

45

35

29

0

0

0

0

0

11

32

50

41

43

39

37

36

44

36

25

8

0

0

0

0

18

37

57

50

38

33

46

29

49

67

33

9

0

0

0

0

18

38

43

36

36

18

21

31

53

33

40

15

0

0

0

0

23

30

35

37

30

1

13

31

28

24

19

15

0

0

0

1

35

36

43

34

28

0

4

26

35

44

36

17

0

0

0

0

36

44

47

35

12

0

0

20

28

30

35

14

0

0

0

0

40

43

45

36

19

0

1

24

29

43

41

12

0

0

0

0

32

45

37

39

30

0

11

39

34

48

34

7

0

0

0

0

23

35

48

49

28

0

18

40

42

42

29

0

0

0

0

0

18

55

47

43

20

0

14

38

51

49

24

0

0

0

0

0

11

41

52

40

8

0

8

39

50

32

14

0

0

0

0

0

6

45

50

37

3

0

4

39

52

40

9

0

0

0

High Pressure

• •

0

1

0

0

2

12

12

7

8

7

10

2

0

0

0

8

0

0

0

8

30

32

22

22

22

49

27

23

1

0

0

0

190 180 170 160 150 140 130 120

Medium Pressure

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

67.44

80

Average (mmHg)

20.54

70

Variance (mmHg²)

355.42

60

Standard deviation (mmHg)

18.85

50

Coefficient of variation (%)

91.79

40

Horizontal center (in)

8.61

30

Vertical center (in)

8.74

Sensing area (in²)

320.89

20

Regional distribution (%)

100.00

No Pressure

10 0 mmHg

mmHg

mmHg

IMMERSION & ENVELOPMENT

200

200 190 180

Lumbosacral contouring intelligently accommodates the gluteal shelf, allowing users to sit right back into the upholstery for improved positioning and immersion 0

0

2

25

23

58

60

37

49

51

41

39

18

0

0

0

170

0

0

0

23

47

50

60

39

42

34

39

32

26

2

0

0

160

0

0

11

33

49

40

40

40

37

38

50

31

23

8

0

0

0

0

17

39

57

44

42

33

42

34

40

70

35

9

0

0

130

0

0

17

31

43

35

34

18

21

34

50

35

44

14

0

0

120

0

0

21

30

37

38

30

2

12

32

26

24

17

13

0

0

0

0

35

35

44

34

30

0

4

26

36

42

40

16

0

0

0

0

37

45

43

34

11

0

0

19

29

34

33

14

0

0

150 140

Designed with Dartex PU Fabric to maximise skin Immersion (Figure 1.3) and Envelopment (Figure 1.4) which is fundamental for a support surface to effectively redistribute pressure improving blood flow which promotes healing 0

0

40

39

43

36

18

0

2

22

32

43

38

13

0

0

0

0

32

42

37

43

28

0

12

37

40

43

32

9

0

0

FIGURE 1.3 0

0

22

34

50

48

27

0

18

40

39

42

32

0

0

0

0

0

17

53

47

44

20

0

14

38

47

45

25

0

0

0

0

0

10

40

48

41

9

0

9

39

47

36

15

0

0

0

0

0

6

43

52

37

3

0

4

41

48

38

9

0

0

0

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

70.26

80

Average (mmHg)

20.39

70

Variance (mmHg²)

350.55

60

18.72

50

91.81

40

8.61

30

Vertical center (in)

8.76

Sensing area (in²)

320.89

20

Regional distribution (%)

100.00

Standard deviation (mmHg) Coefficient of variation (%) Horizontal center (in)

FIGURE 1.4 10 0 mmHg

6

200

0

1

0

0

2

11

11

8

7

9

9

3

0

0

0

9

0

0

0

8

32

29

27

20

24

49

28

23

1

0

0

0

0

0

2

25

26

55

60

37

46

53

40

37

20

0

0

0

170

0

0

0

22

47

53

58

34

45

36

45

31

29

2

0

0

160

0

0

11

33

49

40

38

42

41

35

47

37

25

8

0

0

0

0

18

42

68

52

41

31

42

29

42

57

35

10

0

0

130

0

0

20

35

45

42

34

19

22

30

45

33

44

15

0

0

120

0

0

22

35

33

36

32

1

12

35

27

25

20

15

0

0

0

0

35

33

39

34

29

0

4

26

33

42

38

17

0

0

0

0

36

41

45

34

11

0

0

20

27

32

32

12

0

0

0

0

38

41

47

38

19

0

1

24

30

45

35

12

0

0

0

0

32

42

38

37

28

0

11

37

38

50

32

7

0

0

0

0

23

35

46

48

27

0

18

37

38

47

32

0

0

0

0

0

17

54

46

44

20

0

14

40

50

45

24

0

0

0

0

0

10

40

49

39

8

0

9

32

49

34

15

0

0

0

190 180

150 140

110 100

Minimum (mmHg)

0.00

90

Maximum (mmHg)

68.36

80

Average (mmHg)

20.43

70

Variance (mmHg²)

350.02

60

Standard deviation (mmHg)

18.71

50

Coefficient of variation (%)

91.56

40

Horizontal center (in)

8.59

30

Vertical center (in)

8.80

Sensing area (in²)

320.89

20


PATIENT SURFACE GENUINE DARTEX® PU FABRIC Well respected in the healthcare industry, Dartex® PU fabric is the perfect patient surface solution for treatment and management of pressure injuries through it’s 5 key characteristics (Figure 1.5).

FIGURE 1.5

Vapour

Optimal Barrier

Breathable. Maintains a healthy microclimate

Prevent fluid ingress and improve infection rates

Extension

Contact

Prevent hammocking through sufficient stretch

With potential for skin contact, safety is key

Reliable

FOR YOUR COVER

Durable fabric that is compatible with most cleaning solutions to ensure stringent infection control standards are met and ensure long term performance

PATIENT & CARER BENEFITS Removable anti-bacterial/ anti-microbial cover for infection control management

Designed specifically for pressure care needs

Waterproof yet breathable for improved skin microclimate

Breathable

TECHNICAL SPECIFICATIONS SEAT HEIGHT

SEAT DEPTH

SEAT WIDTH

SEAT TO TOP OF BACK

OVERALL HEIGHT

OVERALL DEPTH

OVERALL WIDTH

TILT ANGLE

LEG RAISE ANGLE

RECLINE ANGLE

S.W.L

kg

CHP198850 Small CHP198855 Large

650mm

560mm

410mm

630mm

1290mm

690mm

610mm

250

900

500

180kg

650mm

560mm

500mm

630mm

1290mm

690mm

700mm

250

900

500

180kg

* Chair measurements may vary +/– 20mm due to upholstery tolerances * Seat width is taken between the thickest sections of armrest padding * Full range of spare parts available

1

www.aspirecare.com.au 133 120 www.aspirecare.com.au 1300 | 1300 133 120


ASSOCIATED PRODUCTS

TRANSFER AIDS

DAILY LIVING AIDS

AC BEDS

AIR LIFT CHAIRS

OVER TOILET AIDS

OVERBED TABLES

BED STICKS & POLES

FOAM MATTRESSES

AIR MATTRESSES

COMMODES URINALS & BED PANS

SIGNATURE CHAIR

SHOWER STOOLS & CHAIRS

RAISED TOILET SEATS

SHOWER COMMODES

BATH BOARDS & BENCHES

DAY CHAIRS

WHEELCHAIRS

SHELL CHAIRS

PRESSURE CUSHIONS

ASBR16.14 281117

Distributed by:

LIFTERS & SLINGS

www.aspirecare.com.au 1300 133 120


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.