HIGH PERFORMANCE SILENT TECHNOLOGY Environmentally Friendly

TIO ONDI AIR C N COMMERCIAL AIR CONDITIONERS

www.airfel.com


FLOOR STANDING AIR CONDITIONER

R410A

• Enviromentally friendly R410A refrigerant • Simple design, wide digital display • Additional electrical heater • Long piping range • Long blowing range • Failure diagnose system • 4-way automatic air direction • Strong dehumidification • Indoor unit drying system Effective air blowing range up to • 24-hour timer 15 meters with strong fan motors • Sleep mode • Silent operation

Strong heating function designed for stiff winter conditions

3 dimensional homogenous air flow to up-down and right-left directions with automatic air direction wings

24.000 Btu/h 46.500 Btu/h

Indoor unit drying system preventing odour and bacteria

CASETTE TYPE AIR CONDITIONER

R410A • Standard drainage pump • Long piping range • 4-way air blowing system • Strong filtering system • Failure diagnose system • Remote controller • Environmentally friendly R410A refrigerant

18.500 Btu/h 25.000 Btu/h 46.000 Btu/h FLOOR STANDING Model Capacity Cooling Capacity Heating Capacity Electrical Data Power Rated Current

EER

Cooling Heating Cooling Heating Cooling

COP

Heating

Power Input

Performance Dehumidifying Air Flow(L/M/H) Noise Level Overview Dimensions (WxHxL) Net Weight Max. Piping Lenght Max. Level Difference Flare Refrigerent Piping Connection Type Pre-charged Piping Length Compressor Type Refrigerant Refrigerant Amount Additional Refrigerant Charge Operating Range

IU IU OU IU OU IU OU

Liquid Gas

AFS46-0901F/R2

ACS18-0906C/R2

ACS24-0906C/R2

ACS44-0906C/R2

Btu/h kW Btu/h kW

24.090 7,06 26.600 (+7.160) 7,80 (+2,1)

46.500 13,63 50.000 (+8.500) 14,65 (+2,5)

18.500 5,42 22.000 6,44

25.000 7,32 27.000 7,91

44.000 12,89 49.500 14,5

V/Hz A A kW kW

220-240/50 14,3 14,3 (23,26) 2,43 2,35 (+2,1) 2,91 C 3,31 C

380-415/50 8,9 8,7 (14) 4,63 4,56 (+2,5) 2,94 C 3,21 C

220-240/50 9 8,7 1,9 1,87 2,85 C 3,44 B

220-240/50 11,9 11,4 2,42 2,3 3,02 B 3,44 B

380-415/50 8,7 8,5 4,28 4,5 3,01 B 3,22 C

lt/h m3/h dB (A) dB (A)

3 1.100 40/42/45 56

8,5 1.800 46/48/50 59

2 600 43/45/47 56

2,7 1.180 43/45/47 59

7 1.650 48/51/53 60

mm mm kg kg m m inch - mm inch - mm

500x1757x300 1018x840x412 40 69 30 15 3/8" - 9,52 5/8" - 15,88 Havşa 5 Rotary R410A 2.100 60 -7 / 24 21 / 43

590x1870x395 1032x1250x412 63 112 30 20 1/2" - 12,7 3/4" - 19,05 Havşa 5 Scroll R410A 3.600 100 -7 / 24 21 / 43

600x230x600 848x540x320 20 40 20 15 1/4" - 6,35 1/2" - 12,7 Havşa 5 Rotary R410A 1.500 30 -7 / 24 21 / 43

840x260x840 1018x700x412 30 59 30 15 3/8" - 9,52 5/8" - 15,88 Havşa 5 Rotary R410A 2.200 60 -7 / 24 21 / 43

840x320x840 950x1250x412 38 112 50 30 1/2" - 12,7 3/4" - 19,05 Havşa 5 Scroll R410A 3.550 120 -7 / 24 21 / 43

m

Heating Cooling

CASETTE TYPE

AFS24-0901F/R2

gr gr/m °C °C

• The specifications are the values that are measured in standard test conditions.• Cooling test conditions: Outdoor unit ambient temperature 35°C (DB), 24°C (WB), indoor unit ambient temperature 27°C (DB), 19°C (WB) • Heating test conditions: Outdoor unit ambient temperature 7°C (DB), 6°C (WB), indoor un it ambient temperature 20°C (DB) • Airfel has the right to change product specifications and designs without giving information.* Panel values are after-installation values.


DUCTED TYPE AIR CONDITIONER

R410A

• Efficient operation with duct connection • Silent operation • Remote controller • Environmentally friendly R410A refrigerant

18.000 Btu/h

24.000 Btu/h 44.000 Btu/h 60.000 Btu/h

FLOOR - CEILING TYPE AIR CONDITIONER

R410A

• Failure diagnose system • Ceiling or floor installation alternatives • Fan structure designed for silent operation • Long piping range • Long blowing range • Remote controller

24.750 Btu/h 44.000 Btu/h DUCTED TYPE Model Capacity Cooling Capacity Heating Capacity Electrical Data Power Rated Current

EER

Cooling Heating Cooling Heating Cooling

COP

Heating

Power Input

Performance Dehumidifying Air Flow(L/M/H) Noise Level Overview Dimensions (WxHxL) Net Weight Max. Piping Lenght Max. Level Difference Flare Refrigerent Piping Connection Type Pre-charged Piping Length Compressor Type Refrigerant Refrigerant Amount Additional Refrigerant Charge Operating Range

IU IU OU IU OU IU OU

Liquid Gas

ADS24-0907D/R2

ADS44-0907D/R2

ADS60-0907D/R2

ACFS24-0908CF/R2

ACFS44-0908CF/R2

Btu/h kW Btu/h kW

18.000 5,28 20.000 5,86

24.000 7,03 27.500 8,06

44.000 12,9 50.000 14,65

60.000 17,59 63.000 18,5

24.750 7,25 28.500 8,35

44.000 12,89 50.000 14,65

V/Hz A A kW kW

220-240/50 9,4 8,04 1,88 1,7 2,81 C 3,45 B

220-240/50 12,1 11,4 2,33 2,36 3,02 B 3,42 B

380-415/50 9,6 8,9 4,8 4,57 2,69 D 3,21 C

380-415/50 11,8 10 6,2 5,4 2,84 C 3,43 B

220-240/50 11,8 11,7 2,4 2,45 3,02 B 3,41 B

380-415/50 8,7 8,5 4,5 4,55 2,86 C 3,22 C

lt/h m3/h dB (A) dB (A)

2 840 38/40/42 56

2,7 1.400 40/42/44 59

4 2.000 46/48/50 60

7 2.500 48/50/53 64

2,7 1.170 46/48/50 59

4 1.800 48/51/54 60

mm mm kg kg m m inch - mm inch - mm

1012x266x736 848x540x320 36 40 20 15 1/4" - 6,35 1/2" - 12,7 Havşa 5 Rotary R410A 1.500 30 -7 / 24 21 / 43

1270x268x504 1018x700x412 37 59 30 15 3/8" - 9,52 5/8" - 15,88 Havşa 5 Rotary R410A 2.200 60 -7 / 24 21 / 43

1251x290x744 950x1250x412 57 112 50 30 1/2" - 12,7 3/4" - 19,05 Havşa 5 Scroll R410A 3.550 120 -7 / 24 21 / 43

1251x330x788 950x1250x412 66 123 50 30 1/2" - 12,7 3/4" - 19,05 Havşa 5 Scroll R410A 5.000 120 -7 / 24 21 / 43

1300x188x600 1018x700x412 32 59 30 15 3/8" - 9,52 5/8" - 15,88 Havşa 5 Rotary R410A 2.200 30 -7 / 24 21 / 43

1590x238x695 950x1250x412 42 112 50 30 1/2" - 12,7 3/4" - 19,05 Havşa 5 Scroll R410A 3.550 120 -7 / 24 21 / 43

m

Heating Cooling

FLOOR - CEILING TYPE

ADS18-0907D/R2

gr gr/m °C °C

• The specifications are the values that are measured in standard test conditions.• Cooling test conditions: Outdoor unit ambient temperature 35°C (DB), 24°C (WB), indoor unit ambient temperature 27°C (DB), 19°C (WB) • Heating test conditions: Outdoor unit ambient temperature 7°C (DB), 6°C (WB), indoor un it ambient temperature 20°C (DB) • Airfel has the right to change product specifications and designs without giving information.* Panel values are after-installation values.


HIGH PERFORMANCE SILENT TECHNOLOGY Environmentally Friendly...

Commercial Air Conditioners

Rv: R1: 01.02.2011

Authorized Dealer

DAIKIN TURKEY Hürriyet Mah. E-5 Yan yol Üzeri no:57/2 Kartal / ISTANBUL/ TURKEY Tel:(+90 216) 453 27 00 Pbx Fax: (+90 216) 671 06 19 export@daikin.com.tr

www.daikin.com.tr • www.airfel.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.