AKUART Installation Manual | SmartDivider 1 // 4
INSTALLATION MANUAL
SMARTDIVIDER
AKUART Installation Manual | SmartDivider 2 // 4
1
COMPONENTS (included)
TOP WIRES (200 cm) - used to attach the top row of SmartDividers to the ceiling mounts - two per column
SMARTDIVIDER FRAME - comes with four wire locks pre-installed, two in top, two in bottom
SmartDivider frame
CONNECTOR WIRES (20 cm) - two for each middle- and bottom row frames
CEILING MOUNTS - used to attach the top row of SmartDividers to the ceiling - two per column
FLOOR ATTACHMENT KIT (OPTIONAL) FLOOR WIRES (100 cm) - two per column
FLOOR MOUNTS - two per column
2
TOOLS NEEDED (not included)
SCREWS - body diameter max. 5 mm - must be appropriate size for rawl plugs
RAWL PLUGS - two needed per column - must be appropriate size for screws - must be appropriate for ceiling material
POWER DRILL - drill bit must be appropriate size for rawl plugs
LASER LEVEL (suggested) - helps with alignment of frames and drilled holes
WIRE CUTTERS - for trimming excess wire
AKUART Installation Manual | SmartDivider 3 // 4
3
ASSEMBLY - TOP WIRES + CEILING MOUNTS - For each top wire supplied, attach the ceiling mount as illustrated below.
1
2
3
4
ceiling
5
6
top wire (200 cm)
ceiling mount
4
INSTALLATION - TOP WIRES A) Drill holes in ceiling, add rawl plugs. B) For each row of SmartDividers, the distance between the two holes is 45 cm. D) Screw hooks with attached top wires into holes in ceiling. E) The distance between two rows of SmartDividers is 8 cm, which is the same distance as the distance from the side of the SmartDivider to the wire. F) Insert the ends of the top wires into the wire locks on the SmartDividers. Depress the wire lock to release the wire again. G) The top wires can be trimmed to the desired length from ceiling to the top of the SmartDivider columns, plus an additional 5 cm, using wire cutters. Do this before inserting the wires into the wire locks. ceiling
45 cm
24 cm
B
45 cm
24 cm
C G
D
desired length from top of column to ceiling
8 cm
E
8 cm
8 cm
8 cm
5 cm
wire cutter
SmartDivider frame
F wire lock
wire lock SmartDivider frame
8 cm
8 cm
AKUART Installation Manual | SmartDivider 4 // 4
INSTALLATION - ADDITIONAL ROWS A) Use the short connector wires to connect each row to the next as needed. B) The distance between each row of SmartDividers is 8 cm, the same as the distance between each column. C) To adjust the distance between two SmartDivider frames, either push the wire further into the wire lock, or depress the wire lock until it releases the wire. D) Optional: use a laser level to align the columns and rows.
ceiling
8 cm
SmartDivider frame
SmartDivider frame
D
8 cm
connector wire (short)
B connector wire (short)
5
SmartDivider frame
8 cm
laser level
SmartDivider frame SmartDivider frame
C