800-07760 10/10 Rev. A
For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/ Refer to the GSMX and LYNX PLUS, LYNXR-2 or LYNXR-I Installation Instructions for additional information and procedures. If you are installing the Communications Device with a LYNX PLUS control, ensure that the LYNXGSMEXTCB Cable Assembly is properly routed. If used, interconnecting wiring between the cable and the communications device must not exceed 20ft in length.
Connecting the GSMX
It is essential that the wires are spliced exactly as shown on Figure 1. If used, interconnecting wiring between
the two LYNXGSMEXTCB Cable Assembliesmust not exceed 20ft in length.
Table 1 - Cable Assembly LYNXGSMEXTCB Splice Configuration LYNX Series Yellow Red Black Green
GSMX Green Black Red Yellow
LYNX PLUS 10 11 Power Line Carrier Connector
Test Button Super Hi
Battery Connectors
YELLOW
Standard
RED GSM/GSML Port
BLACK
GSMX
GREEN CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
SALCLASSIC 1
2
3
4
OR
YELLOW
GREEN
RED
BLACK
BLACK
RED
GREEN
YELLOW
SPLICE
GSM/GSML Port
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
LYNXR-I / LYNXR-2 SERIES
RED BLACK YELLOW GREEN LYNXGSMEXTCB-001-V0
Figure 1. GSMX Connections
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
OR
WIRE ROUTING TUNNELS
TIE-WRAP POINT TIE WRAP
TIE WRAP MOUNT
NOTE ENSURE ALL WIRING IS ROUTED THROUGH WIRE STRAIN RELIEF CLIP WIRE STRAIN RELIEF CLIP
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
LYNXGSMEXTCB-005-V0
Figure 2. LYNX PLUS Cable Routing
Connecting the GSMV and 7845GSMR Power for the GSMV or 7845GSMR is provided by the LYNX Series Control. Do not install the battery in the GSMV or 7845GSMR. Connecting the battery will significantly decrease the backup battery life of the LYNX Series controls.
LYNX PLUS 10 11 Green Power Line Carrier Connector
Yellow Red
Battery Connectors
Super Hi Standard
BLACK RED
GSM/GSML Port
GREEN YELLOW
Jumper Wire
SALCLASSIC
BLACK RED GREEN YELLOW 1
2
3
4
OR
GSM/GSML Port
LYNXR-I / LYNXR-2 SERIES
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
BLACK
ECP + GND ECP In ECP Out
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
TB 1 1 2 3 4 5 6 7 8 9 10 11
CABLE ASSEMBLY LYNXGSMEXTCB (P/N 600-00151)
7845GSMR OR GSMV
RED GREEN YELLOW
LYNXGSMEXTCB-006-V0
Figure 3. 7845GSMR or GSMV Connections
800-07760 10/10 Rev. A
2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2010 Honeywell International Inc. www.honeywell.com/security