design portfolio Anthony Saofan Liang Bachelor of Environments 699583
30.04.2019
table
of
contents
professional work the bays private hospital
1.0 1.1
academic work design studio: air construction design design studio: fire
2.0 2.1 2.2 2.3
personal work oils & acrylic watercolour
3.0 3.1 3.2
1.0 professional work
1.1
the bays private hospital
The Bays Private Hospital Expansion is a 6 bed ICU expansion by Silver Thomas Hanley which joins to the original existing building built in 1992, by Irwin Alsop Architects and a more recent addition in 2010, also by STH Architects. I have been a part of the project since Schematic Design, and have seen the projec through to completion in the beginning of May 2019. My role, responsibilities and activities in the project has been extensive, my tasks have included; documentation, model manager, services coordination, interior design, special joinery, fitout, partition detailing, RFI management, on site inspections, shop drawing approval, construction progress meetings, client interaction and defecting. All work from this section has been completed by myself, Anthony Liang and has been checked by Ian Wong at Silver Thomas Hanley architects. Personal input: 80-90%. All photos used have been taken by myself. KEY PLAN
KEY PLAN
2
3
4
N
selected sheets from construction set
1
REV
DESCRIPTION
DRN
DATE
C1
ISSUED FOR CONSTRUCTION
ASL
24/10/2018
30.050 Level 01 Ceiling
EX. LEVEL 01 INPATIENT BEDROOM
DATE 24/10/2018
800
28.150 Parapet
26.700 Ground Floor Ceiling
Ele vat ion
COPYRIGHT
DIMENSIONS
1
2
3
EXTEND EXTERNAL WALL TO MATCH ADJACENT PARAPET HEIGHT - WALL TO BE CONSTRUCTED WITH MAXIFRAME STUDWORK AND FIBRE CEMENT SHEET CLADDING, PAINTED TO MATCH PRECAST
900
1531
30.525 Top of Existing Eaves 30.050 Level 01 Ceiling
EQ
28.200 Level 01 Sill
EQ
2
28.150 Parapet
io vat Ele
27.350 Level 01 26.700 Ground Floor Ceiling W.02
W.01
n1
150
24.000 Ground Floor Level
A51-001
SERVICE POINTS DISCLAIMER
A
ISSUED FOR CONSTRUCTION
3D Isometric Elevation Diagram
23.620 Plant Enclosure Slab Level
SCALE: 1 : 50
SERVICE POINTS DISCLAIMER THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
EXISTING AMBULANCE BAY
TOP OF FOOTING NOMINAL RL 22.51
2
North-South Section
1
B
C
E
ARCHITECTS
1 A51-001
Elevation 1
30.525 Top of Existing Eaves
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
SCALE: 1 : 100
A
1
B
C
D
E
1
30.525 Top of Existing Eaves 30.050 Level 01 Ceiling 4644
PC01
705
W.10
900
4644
PC01
962
W.08
962
900 W.07
PC01
920
900
962
962
900
W.06
EXTEND EXTERNAL WALL TO MATCH ADJACENT PARAPET HEIGHT - WALL TO BE CONSTRUCTED WITH MAXIFRAME STUDWORK AND FIBRE CEMENT SHEET CLADDING, PAINTED TO MATCH PRECAST
2567
28.200 Level 01 Sill 28.150 Parapet
PC01
920
W.05
900
962
962
27.350 Level 01
900
W.04
705
855
26.700 Ground Floor Ceiling
W.03
900
SKYLIGHT AND FEATURE BULKHEAD AS SPECIFIED
26.700 Ground Floor Ceiling PROJECT
EX. ENS
The Bays ICU Expansion
ICU 5 ICU.005
26.700 Ground Floor Ceiling
2700
Vale St, Mornington VIC 3931
150
DRAWING TITLE
22.97
22.93
24.000 Ground Floor Level
TOP OF FOOTING RL 22.51
22.84
22.76
EXISTING PERFORATED METAL SCREEN TO PLANT ENCLOSURE
200
23.01
150
PLANT ENCLOSURE SLAB LEVEL RL 23.62
23.620 Plant Enclosure Slab Level 22.740 Existing Natural Level
22.71
EXTERNAL ELEVATIONS
24.000 Ground Floor Level 23.490 Ambulance Entry level 22.740 Existing Natural Level
Elevation 3
3
REFER TO CIVIL DRAWINGS FOR FINISHED GROUND LEVEL. DEPTH OF FOOTING TO BE MIN 200mm BELOW LOWEST POINT OF GROUND LEVEL TO TOP OF FOOTING.
EX. CORRIDOR
27.350 Level 01
959
W.11 W.09
1500
SCALE
SCALE: 1 : 100
1 : 100@A1 PROJECT No
DATE
DRAWN BY
CHECKED
06/28/18
ASL
IW
DRAWING No
REVISION
C1
CORRIDOR ICU.C01
CORRIDOR ICU.C03
STAFF STATION ICU.011
The Bays ICU Expansion
PAT ENS ICU.017 AMBULANCE ENTRY RAMP
DRAWING TITLE
24.000 Ground Floor Level 23.620 Plant Enclosure Slab Level 23.490 Ambulance Entry level
SCALE
1 : 50@A1 PROJECT No
SCALE: 1 : 50
3
3000
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
• R'w 45 WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING • TOTAL R VALUE R1.1m (T1) MIN REQUIREMENT WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING • WASTE PIPES LOCATED WITHIN PARTITION SHALL BE LAGGED AS PER ACOUSTICS SPECIFICATIONS
•
• •
FIRE GRADE ELASTOMERIC SEALANT BETWEEN WALL SHEETING & FLOORING FOR ACOUSTIC & FIRE INTEGRITY
• •
FLOOR LEVEL
• •
PARTITION ACHIEVES • 2 HOUR FIRE RATED WALL (F2) • R'w 32 (A1) WITHOUT INSULATION • R'w 40 (A2) WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING • R'w 50 (A4) WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING • TOTAL R VALUE R1.1m (T1) MIN REQUIREMENT WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING
•
• • • • • • • • • • • • • • • • •
PARTITION SECTIONS ARE INDICATIVE OF WALL THICKNESS, ACOUSTICS, SECURITY, FIRE & SMOKE STEEL STUDS SHOWN ARE GENERALLY INDICATIVE ONLY CEILING SLAB JUNCTIONS ARE INDICATIVE ONLY. WALL NOGGINS - REFER TO KIT OF PARTS (60 SERIES) ONLY LIGHT WEIGHT FIXTURES AND WALL CLADDING TO BE FIXED TO STEEL FRAME NOGGINS - STEEL FRAME. NOGGINS INDICATED ON PARTITION SECTIONS ARE GENERALLY INDICATIVE ONLY THAT NOGGINS ARE REQUIRED STEEL NOGGINS AS SUPPLIED BY MANUFACTURER TIMBER NOGGINS - STRUCTURAL PLY AS REQUIRED FOR ALL FIXTURES, FITTINGS, HANDRAILS, BUFFER RAILS, GRAB RAILS, EXCEPT WALL HUNG BASINS ALL NOGGINS TO BE FLUSH WITH FACE OF STUD & AT CENTRE OF CEILING / PARTITION CONNECTION OR WALL HEIGHT ALL LININGS TO BE FULL HEIGHT UNLESS NOTED OTHERWISE (U.N.O) ALL WALL LININGS TO BE FIXED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN SPECIFICATIONS. ALL VERTICAL JOINTS TO BE BACK BLOCKED AND STAGGERED CONTROL/EXPANSION JOINTS - PROVIDE/INSTALL TO MANUFACTURER'S RECOMMENDATIONS AND DETAILS. LOCATION TO BE APPROVED BY RELEVANT PROJECT CONSULTANT BLOCKWORK WALLS - REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR REINFORCEMENT AND FIXING DETAILS ACOUSTICS - LININGS TO WALLS AS REQUIRED BY ACOUSTIC ENGINEERS SPECIFICATION HYD. STACK RISERS TO BE LAGGED PIPE WORK TO ACOUSTIC ENGINEERS SPECIFICATION FULL HEIGHT SS WALLS - ALL TO BE FITTED WITH DEFLECTION HEADS TO ACCOMMODATE HEAVE AND DEFLECTION WHERE LOADS EXCEED MANUFACTURER'S SPECIFICATION, STRUCTURAL SECTION TO BE INCORPORATED IN PARTITIONS TO MANUFACTURERS DETAILS FIRE SERVICE PENETRATIONS THROUGH WALLS - REFER ENGINEER'S DOCUMENTS FOR FIRE ISOLATION OF SERVICES REFER ENGINEER'S DOCUMENTS UNLESS NOTED OTHERWISE (U.N.O) ALL ABOUNDING PLANT ROOMS AND DUCTS SHALL HAVE FULL HEIGHT ACOUSTIC WALLS PLASTIC PLUMBING IN FIRE WALLS - FIRE COLLAR AT EXIT POINT FOR CEILING HEIGHTS REFER TO THE 30 SERIES BLOCKWORK ALIGNED WITH CONCRETE UNLESS SPECIFIED RENDER/HARD PLASTER TO CONTINUE ON CONCRETE FACE IF WALLS ALIGNED AND HAVE A RENDER/HARD PLASTER FINISH WHERE A CONTROL JOINT (CJ) IS INDICATED IN CORE FILLED BLOCKWORK AT A DOOR/WINDOW OR ALIKE, ALLOW FOR A FULL BLOCK BETWEEN THE CJ AND THE OPENING OVERALL WIDTH OF PARTITIONS INDICATED MUST NOT CHANGE IF THERE ARE MULTIPLE WALL LINING CODES THE CODE FOR THE SIDE THE WALL TAG IS ON MUST BE SHOWN FIRST FOR ALL SISALTION REQUIREMENTS, REFER TO FACADE CONTRACTORS DOCUMENTATION
DRAWING TITLE
SCALE
1 : 10@A1 PROJECT No
DATE
DRAWN BY
CHECKED
08/16/18
ASL
IW
DRAWING No
REVISION
C1
150
EQUAL
1570
443
740
740
600
250
ICU.016
EQ EQ
D.13 1100 T1FGALS
MPICUP2
700
TLICUB
900
PBCB
CG2100
EPOE2 COMD
TLLND
COPYRIGHT
24.000 Ground Floor Level
BEDICU
150 FFL
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
300
ICU.002 - ICU-2
A
CTCM
3000
DISGD DISPD DISSD DISAD EC SAC PSP ICSM ELSW1
600
HB1S
3000
CTCM
2700
D.06 1800 T1FGALS
CLSL IW.10 IWA 600
2100
CTCM
2700
2100
REV
T
WSICU
WSICU
MPICUP2
EPOC
BINW20
BINW20
150 FFL
B
A61-001 SCALE: 1 : 50
150 FFL
ICU.002 - ICU-2
ICU.018 2700PBC
ICU.017
1
2
2
3000
CLSL
2700
CLSL
ICU.019
2700PBC
TLICUB
CTCM PBCB
ASB
ICU.003 - ICU-3
3000
CTCM
1400 1100
HB-1S
900 800 600
HB-1S BINC50
BINW20
150 FFL
ICU.003 - ICU-3
W.07
WSICU
MPICUP2
600
UPSM
TLLND
600 450
ENS
ENS
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
PBCB
BED
875
1 BED
EXTEND EXISTING PARAPET TO NEW PARAPET HEIGHT
28.200 Level 01 Sill 28.150 Parapet 27.350 Level 01
1 BED
PLTS 3000 MPICUP2
LMBH
The Bays ICU Expansion
AMBULANCE AIRLOCK
DRAWING TITLE
3
4
A30-001 Reflected Ceiling Plan
SERVICE POINTS DISCLAIMER
TLICUB
312
ICU.003
A61-001 SCALE: 1 : 50
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
MPICUP2
MPICUP2
SCALE
DATE
DRAWN BY
CHECKED
As indicated@A1
06/28/18
ASL
IW
PROJECT No
DRAWING No
10341 A30-001
100
REVISION
C6
1400
ISSUED FOR CONSTRUCTION
BEDICU
EC SAC ELSW1
BEDICU
TLLND
ELDLNR
EPOC
650
A
ICSM
120
IW.15 IWA 1250
ICU.004 - ICU-4
B
WSICU BEDICU
ICU.004 - ICU-4
PLTS 3000
MPICUP2
100
W.11
HB-1S
1500
900
C
A61-001 SCALE: 1 : 50
CLSL
TVLCD44
IW.14 IWA 1300
150 FFL
150 FFL
A61-001 SCALE: 1 : 50
D.08 1800 T1FGALS 1500
700 600
BEDICU
EPOE1
650
ASB
2500 2100
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
T
1200
HB-1S
BINW20
TLICUB
900 800 750 600
COMDD EPOE2
ICU.004 - ICU-4
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
COMD EPOE2 TLLND
BINC50
120
D
A61-001 SCALE: 1 : 50
BEDICU BINW20
150 FFL
300
900
ICU.004
ICU.004 - ICU-4
A61-001 SCALE: 1 : 50
The Bays Healthcare Group
PROJECT
WSICU
PROJECT
The Bays ICU Expansion
CHST EXISTING AMBULANCE RAMP
Vale St, Mornington VIC 3931 DRAWING TITLE
22.740 Existing Natural Level 3 A52-001
Section through ICU.001 & Ambulance Ramp
SCALE: 1 : 50
SECTIONS 2
2 A51-001
SCALE
1 : 50@A1 PROJECT No
DATE
DRAWN BY
CHECKED
08/09/18
ASL
IW
DRAWING No
10341 A51-002
A51-002 Sections
EQ 2700
24.000 Ground Floor Level 23.490 Ambulance Entry level
2
700 600 400 150 FFL
CLSL
TVLCD44 2100
IW.16 IWA 547
350
2700
TVLCD44
100
1400 1250 1100
EPJ
MSP
UPSM
1600
TLICUB
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
The Bays Healthcare Group
26.700 Ground Floor Ceiling
TVLCD44
100
2700
PLTS 3000
IW.07 IWA 900
IW.08 IWA 820
EX WINDOW REMOVED AND WALL INFILLED WITH STUDWORK AND PLASTERBOARD LINING, PAINTED TO MATCH ADJACENT WALL, SMOKE RATED
Vale St, Mornington VIC 3931
2700PBC
EPOE1
650
ICU.003 - ICU-3
D
ARCHITECTS
2700
PLTS 3000
CLSL
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
The Bays Healthcare Group
2700PBC
EPJ
ELDLNR
TLLND
150 FFL
300
ICU.003 - ICU-3
A61-001 SCALE: 1 : 50
W.08
100 MSP
BEDICU
900
COMD EPOE2
EQ
100
1400
BEDICU
BINW20
EQ
C
A61-001 SCALE: 1 : 50
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
MPICUP2 2100
EC SAC ICSM ELSW1
1600 2700
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
ICU.020
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
PLTS 3000
2700
IW.11 IWD 1420
1600
B
A61-001 SCALE: 1 : 50
PLTS 3000
2100
IW.12 IWA 600
BEDICU WSICU
TLICUB
900
150 FFL
360
A
30.050 Level 01 Ceiling
800 1200
COPYRIGHT
ICU.002
ARCHITECTS
2400WAP-01
EQUAL
900
TLLND
EQ
TVLCD44
D.07 1800 T1FGALS
IW.13 IWA 2124
1500
WSICU
EPOC
600 150 FFL
ISSUED FOR CONSTRUCTION
3000 2700
TVLCD44 2100
600 T
BEDICU
30.525 Top of Existing Eaves
OFFICE 900 1200
TLICUB
312
EQ
1570
CTCM
TVLCD44
MPICUP2
1500
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
3
A51-001
W.09
2100
900
SERVICE POINTS DISCLAIMER
1
CTCM
PLTS 3000
2700
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
ICU Section through ward
SCALE: 1 : 50
POWDERCOATED PANEL OVER TO MATCH WINDOW & DOOR FRAME
EQ
3000
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
3600
OFFICE
650
ICU.002 - ICU-2
A61-001 SCALE: 1 : 50
DIMENSIONS
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
EQ
22.740 Existing Natural Level
1295
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
DATE
24/10/2018 03/01/2019 15/01/2019 12/02/2019 25/03/2019 09/04/2019
EPOE1 W.06
650
D
A61-001 SCALE: 1 : 50
EPJ
ELDLNR W.05
150 FFL
DIMENSIONS
DIMENSIONS
ASL ASL ASL ASL
100 MSP
BEDICU PROWD1
600
600
C
ICU.002 - ICU-2
A61-001 SCALE: 1 : 50
100
UPSM
900
BEDICU
400
BINC50
DRN
ASL
2100
MPICUP2 1400
900 600
115
DESCRIPTION
ISSUED FOR CONSTRUCTION INTERNAL ELEVATION ROUGH IN ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION
CTCM
2700
IW.08 IWA 820
IW.07 IWA 900
1500
BEDICU HB-1S
2100
800
MEDICATIONS
PAT ENS
ICU.001
TVLCD44
IW.09 IWA 2124
TVLCD44
1500
900
3000
PLTS 3000
TLICUB
2500PBC
312
A61-001 SCALE: 1 : 50
C1 C2 C3 C4 C5 C6
1570 ASB
CGFH
2650PBC
2500MFT
EPOE1
650
ICU.001 - ICU-1
D
A61-001 SCALE: 1 : 50
EPJ
BEDICU ELDLNR
150 FFL
POWDERCOATED PANEL OVER TO MATCH WINDOW & DOOR FRAME
POWDERCOATED PANEL OVER TO MATCH WINDOW & DOOR FRAME
TVLCD44
IW.11 IWD 1420
1100
EX. CORRIDOR
TLLNCS
PROJECT
2
2100
1600
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
GROUND LEVEL REFLECTED CEILING PLAN
1
26.700 Ground Floor Ceiling
WPFH
PBCB
400
600
2650MFT
2700WRPC
B-RESUS
1778
WPFH
ISSUED FOR CONSTRUCTION
610
E
ASB
ICU.001 - ICU-1
ROWO
TLLND
400
100 MSP
UPSM
TLICUB
600
TLLND
300 300 320
BINC50
1000
815
WPFH
1400
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
2700PBC
554
CTCM
3000PBC 1783
IW.17 IWA 1300
C
ICU.001 - ICU-1
A61-001 SCALE: 1 : 50
BINC50
PBCB
2400WAP-01
1004
1004 EQ
EQ EQ
PLTS 3000
EQ
1006 500
30.96°
1006
1556
4200
514
D.10 1800 T1FGALS
100 1400
900
COMDEPOE2
BINC50
BINW20
150 FFL
30.840 Level 02 ICU.C03
CONTINUOUS ALUMINIUM PELMET, WITH PLASTERBOARD OVER TO FULL LENGTH OF ROOM
WPFH
SERVICE POINTS DISCLAIMER
ICU.024
CLEANER
2400 PBC
ENS
ICU.015 2400WRPC
2700
230 CTCM
EQ
808
199 89 EQUAL
250
2400
ICU.011
250
2400PBC
PLTS 3000
EQ
808 1198
1209
1198
2405 1659
1608
STAFF STATION
1608
10800
ANTE
ICU.014
D.08 1800 T1FGALS
ARCHITECTS
CORRIDOR
CTCM
ICU.001
The Bays ICU Expansion
PARTITION DETAILS 1
UPS
2700 PBC ANGLED CEILING
944
EQ
PROJECT
Vale St, Mornington VIC 3931
TVLCD44
TVLCD44 PBCB
ICU-2
ICU.002
ICU-1
2505 1570 1305
STORE
700 3000
WSICU
1361
2400
1800
1700
1200 2959
2959
EQ 2400 EQ 1800
ICU.013
IW.14 IWA 1300
W.04
2100
MPICUP2
BEDICU
600
BINW20
MPICUP2
W.03
W.02
WSICU
900
TLICUB
WSICU
B
CLSL
ICU.C02
780
3000PBC
D
The Bays Healthcare Group
10341 A24-001
A24-001 Partition Details
1700
1037 THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
1570
APPLICATION NOTES • •
75mm THICK 11kg/m³ INSULATION, ONLY REQUIRED WHERE WALLS ARE CODED WITH A4 &/OR A T AS SPECIFIED
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
PARTITION ACHIEVES
2 LAYERS OF 16mm FIRE RATED PLASTERBOARD WALL LINING EACH SIDE OF STUD FRAMING UNO
POWER POINTS IN FIRE WALLS ARE TO BE OF FIRE PROOF CONSTRUCTION ALL POWER POINTS ARE TO BE FITTED WITH ACOUSTIC WALL BOXES POWER POINTS LOCATED BACK TO BACK IN THE SAME WALL ARE NOT TO BE LOCATED BETWEEN THE SAME STUDS (REFER DETAIL) R2.0 POLYESTER INSULATION IS ACOUSTIC
CORRIDOR
2650PBC
BAY-HB
PLANT STORE
DATE 24/10/2018
REVISION
C1
EQ
CTCM
100 MSP
EPJ
UPSM
BEDICU ELDLNR
EPOE1
650
A
ICU.005 - ICU-5
A61-001 SCALE: 1 : 50
EPOC
650
TLICUB
TLLND
CLSL
TLICUB
TLLND
900
B
CTCM TVLCD44
TVLCD44 D.10 1800 T1FGALS
IW.17 IWA 1300
700 600
BINC50
BINW20
BINW20
150 FFL
IW.15
WSICU
IW.16 IWA 547
120 IWA 1250 1600
EC SAC
1400 1300 1250
BEDICU
TLICUB
EPOE2 COMD
600 150 FFL
2700
CTCM
HB-1S HB-1S
900
600
2700
CLSL
MPICUP2
1500
900
150 FFL
CTCM
PLTS 3000
2500 2100
MPICUP2
100 1400
The Bays ICU Expansion
1600 2700
PLTS 3000
2100
CGFH
ACOUSTIC SEALANT FLOOR LEVEL
FLOOR LEVEL
• R'w 45 (A3) WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING. DOUBLE LAYER OF WALL LINING TO BE APPLIED ROOM SIDE, WITH THE OUTER LAYER TO TERMINATE 50mm ABOVE CEILING. • WHERE HYDRAULICS SERVICES ARE LOCATED WITHIN THE PARTITION, STAGGERED STUDS SHALL BE LOCALLY INCORPORATED • ALL WALL PENETRATIONS TO BE ACOUSTICALLY SEALED. GPO'S TO HAVE ACOUSTIC BOX (HPM FIREBOX) BEHIND OR OFFSET 600mm • CEILING PENETRATIONS INCLUDING MECHANICAL VENTILATION GRILLES TO BE ACOUSTICALLY TREATED WITH PLENUM BOX TO REAR OF THE GRILLE WITH OFFSET SPIGOT & ACOUSTIC FLEXIBLE DUCTING
92mm RONDO QUIT STUDS @ MAX 600mm cts
NOTE: ALL PENETRATIONS IN THIS WALL MUST COMPLY WITH RELEVANT CODES FOR FIRE WALLS (ALL OPENINGS TO BE SEALED)
C1
CTCM
PLTS 3000
2700
HB-1S
1500
HB-1S
BEDICU
900 800
150 FFL
A61-001 SCALE: 1 : 50
28.150 Parapet
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
NEW PLASTERBOARD CEILING TO EXISTING CORRIDOR
1500
EQ
1474
606
EX WINDOW
DRN ASL
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
ACOUSTIC SEALANT
PARTITION ACHIEVES
• • •
250mm INTERNAL RADIUS
2650MFT
EX WINDOW
DESCRIPTION ISSUED FOR CONSTRUCTION
D.13 1100 T1FGALS
75mm THICK 11kg/m³ INSULATION
REVISION
WALL ON ANGLE 3000
CLSL
2100
D.05 2150 T1FGALS
1200
100
ICU.001 - ICU-1
A
27.350 Level 01
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
1 LAYER OF 13mm PLASTERBOARD WALL LINING EACH SIDE OF STUD FRAMING UNO
75mm THICK 11kg/m³ INSULATION
BASIN & SINK WASTE DISCHARGING INTO FIRE & SMOKE WALL TRAPS & PIPE INTO WALL ARE TO BE COPPER & CONNECT TO PVC WASTE PIPE IN WALL & THE PENETRATION TO BE FIRE SEALED. IF PLASTIC PIPES ARE BEING USED IN FIRE WALL, FIRE COLLARS ARE ALSO TO BE INSTALLED AT WALL PENETRATION
OTHER GENERAL NOTES
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
1500
1498
150mm GALV STEEL WALL STUDS @ MAX 600mm cts
2 LAYER OF 13mm PLASTERBOARD WALL LINING UNO WITH OUTER LAYER OF LINING TO ROOM SIDE TO TERMINATE 50mm ABOVE CEILING LINE
•
1800
ICU.023
2700PBC
MPICUP2
1046
92mm GALV. STEEL WALL STUDS @ MAX 600mm cts
CORNICE AS SCHEDULED
2200
1046
CL VARIES REFER TO RCP FOR CEILING TYPE & HEIGHT
CORNICE AS SCHEDULED
1570
EQ
1 LAYER OF 13mm PLASTERBOARD WALL LINING
CL VARIES REFER TO RCP FOR CEILING TYPE & HEIGHT
EQ
80
4334
EQ
OUTER LAYER OF LINING TO ROOM SIDE TO TERMINATE 50mm ABOVE CEILING LINE
•
CL VARIES
CORNICE AS SCHEDULED
2959
2409 ARCHITECTS
IN-WALL BOXES SHALL BE SMOKE PROOF CONSTRUCTION GAS LINES TO BE RUBBER GROMMETED INTO GAS BAR BOXES TO BE FIRE SEALED AROUND WALL PENETRATION GAS LINES ENTERING FH SMOKE WALLS TO BE SMOKE SEALED AT WALL PENETRATION
WASTE PIPE FIRE WALL PENETRATIONS
REFER TO RCP FOR CEILING TYPE & HEIGHT
2505 1305
800
U.N.O. ALL DOORS ARE TO BE SET-OUT 100mm FROM FACE OF PERPENDICULAR WALL OR COLUMN
100
3000PBC
C
ISSUED FOR CONSTRUCTION
MEDI-GAS BOXES IN SMOKE WALLS • • • •
1800
ICU-3
ICU.003
ICU.012
1386
1504
•
1570
2700PBC ICU-6 ISO
1236
670
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
749
2400WAP-01
1659
20mm CLEARANCE TO PLASTERBOARD FIRE GRADE ELASTOMERIC SEALANT BETWEEN WALL SHEETING & FLOORING FOR ACOUSTIC & FIRE INTEGRITY
2200
100 80 690
LMBH
UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB
SERVICE POINTS DISCLAIMER THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
EX WINDOW
REV C1
2200 2100
EC SAC ICSM ELSW1
WALL ON ANGLE
PLTS 3000 W.01
TVLCD44
WSICU
600
ASB
2700
TVLCD44
28.200 Level 01 Sill
EXISTING LEVEL 01 INPATIENT UNIT
COPYRIGHT
2400PBC
2040
700
FILL GAPS WITH SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
100
DENOTES CEILING TYPE
DATE 24/10/2018 06/12/2018 15/01/2019 13/02/2019 19/02/2019 07/03/2019
CORRIDOR ICU.012
3600
1236
250 80
1200
2700WRPC
DRN ASL ASL ASL ASL ASL ASL
1 A52-001
ALIGN
20mm CLEARANCE TO PLASTERBOARD
ALIGN
ENS
COMMS
PBC LEVEL 5 FINISH TO INTERNAL LINING OF SKYLIGHT
720
4334
WATER RESISTANT PLASTERBOARD CEILING WALL & CEILING LAMINATE PANEL
DESCRIPTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION
PBCB
CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
DIM DIM CLEAR
FINISHED FACE OF TWO OR MORE ADJACENT OR OPPOSITE WALLS TO ALIGN.
1200
EQ
FILL GAPS WITH SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
100 MAX.
20mm CLEARANCE TO PLASTERBOARD
DIMENSION TO FINISHED FACE CLEAR WIDTH OF CORRIDOR
156mm NOM.
TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB
DIM
DIMENSION TO CENTRE LINE OF STUD
P3_F2 (2 HR FIRE RATED)
P3 176mm NOM.
TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
GENERAL DIMENSIONS
GENERAL STUD PARTITIONS
GENERAL STUD PARTITIONS
P2 131mm NOM.
1200
EQ
SET-OUT PRIORITY/NOMENCLATURE
GENERAL STUD PARTITIONS
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
WRPC WAP
REV C1 C2 C3 C4 C5 C6
WPFH
2500MFT
ICU.010
250mm INTERNAL RADIUS
1200x600 MINERAL FIBRE TILE CEILING
NEATLY FINISH ALL JUNCTIONS BETWEEN NEW AND EIXISTING CEILING FINISH
159
BAY-PATH
TVLCD44
PARTITION WALL DETAILS & PARTITION PLANS ARE TO BE READ IN CONJUNCTION WITH GENERAL ARRANGEMENT PLANS, "A24-000" SERIES & CONSULTANTS DOCUMENTS. ALSO REFER TO OTHER ARCHITECTURAL PLANS, SECTIONS, ELEVATIONS & DETAILS FOR REQUIRED DIMENSIONS REFER TO ARCHITECTURAL SPECIFICATIONS PARTITIONS & CEILINGS REFER TO DOOR AND HARDWARE SCHEDULE & "A60-000" SERIES (KIT OF PARTS) DRAWINGS FOR DOOR & WINDOW ATTRIBUTES AS WELL AS SIZING U.N.O. ALL DOORS ARE TO BE SET-OUT 100mm FROM FACE OF PERPENDICULAR WALL OR COLUMN DEPARTMENT/SMOKE/FIRE DOORS TO BE CENTERED IN CORRIDORS UNLESS DIMENSIONED OTHERWISE POSITION OF ALL EXISTING WALLS & CORES TO BE CONFIRMED ON SITE DIMENSIONS MEASURED ON SITE SHALL TAKE PRECEDENCE OVER DIMENSIONS ON THE DRAWINGS. FOR ALL CURVED WALLS, USE RONDO FLEXI-TRACK WITH LININGS AS CODED. COORDINATE STUDWORK WITH BEDHEAD SERVICES REFER TO "A71-000" SERIES (SPECIAL JOINERY) DRAWINGS FOR SETOUT OF SPECIAL JOINERY UNITS
1305
EQ
• • •
ENS
450
2650PBC
1660
• • •
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
MFT
150 FFL
30.050 Level 01 Ceiling
BAY
ICU.009
TVLCD44
• • •
2100 PBCB
2500PBC
1200
1800 2505
1664
•
1570
EQ
PARTITION DIMENSIONING NOTES
• SMOKE WALL (SM) • R'w 32 WITHOUT INSULATION • R'w 40 (A) WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING
B
MDF CEILING BULKHEAD
601
BAY-HB
1145
DIMENSIONS
FLUSH PLASTERBOARD CEILING BULKHEAD
REFER TO ELECTRICAL, MECHANICAL, HYDRAULIC AND FIRE SERVICES ENGINEER'S DRAWINGS FOR ALL CEILING MOUNTED SERVICES AND DETAILS
ALIGN
PLTS 3000
• R'w 32 WITHOUT INSULATION • R'w 40 (A) WITH 75mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING TERMINATING 50mm ABOVE CEILING & EARTHWOOL INSULATION 1000mm EITHER SIDE OF PARTITION WITHIN CEILING SPACE
• WHERE HYDRAULICS SERVICES ARE LOCATED WITHIN THE PARTITION, STAGGERED STUDS SHALL BE LOCALLY INCORPORATED
NOTE: • Steel studs to external wall as specified • Refer manufactureres reccomendations
SINGLE C STUD - GAUGE AS PER MANUFACTURER'S SPECIFICATIONS COMPRESSED FIBROUS CEMENT BOARD FURRING CHANNEL - GAUGE AS PER MANUFACTURER'S SPECIFICATIONS ACOUSTIC INSULATION CONTROL JOINT
PARTITION ACHIEVES
PARTITION ACHIEVES
PARTITION ACHIEVES • TOTAL R VALUE R3.08m MIN REQUIREMENT WITH 90mm EARTHWOOL 11kg/m³ INSULATION & WALL LINING
SS CFC FC AI CJ
MPICUP2
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
• • • • •
EQ
GENERAL ABBREVIATIONS
EQ
FLOOR LEVEL
2400 PBCB
ICU.C01
8400
1 BED
PBCB MDFB
DENOTES CEILING HEIGHT
ICU.007
2700PBC
ICU.008
COPYRIGHT
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
EQ
PRECAST PANELS (TO ENGINEERS DETAILS)
FLOOR LEVEL
1291
CORRIDOR
PC#
FLOOR LEVEL
1291
1 BED
DIRTY UTILITY
248
TVLCD44
1242
2650PBC
SHAFT WALL SYSTEM
FIRE GRADE ELASTOMERIC SEALANT BETWEEN WALL SHEETING & FLOORING FOR ACOUSTIC & FIRE INTEGRITY
2700PBC
TVLCD44
1302
STUDS WITH NO LINING
431
825
1064
STUDS WITH LINING TO ONE SIDE ONLY
1 BED
2700PBC
1291
ICU.005
1499
STUDS WITH LINING TO BOTH SIDES
S#
SH#
ACOUSTIC SEALANT
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
2700PBC
1063
P#
X#
75mm THICK 11kg/m³ INSULATION, ONLY REQUIRED WHERE WALLS ARE CODED WITH A AS SPECIFIED
EQ EQ
ICU-5
ICU.004
WALL TAG CODE ABBREVIATIONS REPRESENTING DEFAULT WALL TYPES
1 LAYER OF 13mm PLASTERBOARD WALL LINING EACH SIDE OF STUD FRAMING UNO
ACOUSTIC SEALANT
NESTED GALV. STEEL BOTTOM TRACK FIXED TO FLOOR STRUCTURE
ICU-4
ALL PLASTERBOARD LINING TO BE BORAL USG MULTISTOP™ 5 HI (HIGH IMPACT)
PLTS 3000
92mm GALV. STEEL WALL STUDS @ MAX 600mm cts
NOTE: ALL PENETRATIONS IN THIS WALL MUST COMPLY WITH RELEVANT CODES FOR FIRE WALLS (ALL OPENIGNS TO BE SEALED)
75mm THICK 11kg/m³ INSULATION, ONLY REQUIRED WHERE WALLS ARE CODED WITH A AS SPECIFIED
2400PBC
EQ
1291
MPICUP2
1 LAYER OF 13mm PLASTERBOARD WALL LINING EACH SIDE OF STUD FRAMING UNO
170mm PRECAST PANEL TO ENGINEER'S DETAIL (REFER TO PARTITION PLANS FOR PRECAST SIZE)
EQ
P1_A2
PLASTERBOARD SPECIFICATION
EQ
92mm GALV. STEEL WALL STUDS @ MAX 600mm cts
1 LAYER 13mm PLASTERBOARD WALL LINING UNO
EQ
EQ
30.525 Top of Existing Eaves
IW.07 IWA 900
T
BEDICU EPOC
600
FLUSH PLASTERBOARD CEILING
N
600
EQ
EQ
92mm GALV. STEEL WALL STUDS @ MAX 600mm cts
WALL TAG EXAMPLE
80
REFER TO RCP FOR CEILING TYPE & HEIGHT
CORNICE AS SCHEDULED
ICU.006
PLTS 3000
EQ EQ
80
REFER TO RCP FOR CEILING TYPE & HEIGHT CORNICE AS SCHEDULED
90mm THICK 11kg/m³ INSULATION
1200
1700 2400 PLTS 3000
EQ
1636
DATE 24/10/2018
CLEAN STOCK
349
DRN ASL
PLTS 3000
REFER TO RCP FOR CEILING TYPE & HEIGHT
CORNICE AS SCHEDULED
PBC
1555
DESCRIPTION ISSUED FOR CONSTRUCTION
CEILING TYPE LEGEND
EX FHR
3000
CTCM
2700
IW.08 IWA 820
1350 1600 1500 1400 1100
A51-001
2700PBC
1360
POWDERCOATED PANEL OVER TO MATCH WINDOW & DOOR FRAME
3000
CTCM
PLTS 3000
2200 2100
ICU.021
ICU.022
2700PBC
845
EQ
REV C1
MPICUP2
CL VARIES
641
2
SITTING
EDB
MPICUP2
1498
ALL WALLS ARE TAGGED TO REPRESENT THE DEFAULT WALL TYPE & ANY ENHANCED TREATMENTS IF APPLICABLE (AS SPECIFIED BELOW)
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
50
LINING & INSULATION TO TERMINATE 50mm ABOVE CEILING LINE
CL VARIES
621
WALL TAG DESCRIPTION
PARTITION
CL VARIES
572
PBCB
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
MPICUP2
1659
FIRE GRADE ELASTOMERIC SEALANT BETWEEN WALL SHEETING & FLOORING FOR ACOUSTIC & FIRE INTEGRITY
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
LINING REQUIRED FULL HEIGHT WHERE WALLS ARE CODED WITH AN L
652
20mm CLEARANCE TO PLASTERBOARD
1499
100 MAX.
FILL GAPS WITH SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
LINING & INSULATION TO TERMINATE 50mm ABOVE CEILING LINE UNLESS NOTED OTHERWISE.
GRAY HATCH INDICATES EXISTING BUILDING NOT IN WORKS.
NEATLY FINISH ALL JUNCTIONS BETWEEN NEW AND EIXISTING CEILING FINISH
2700PBC
ALL CONCRETE COLUMNS, LIFTS & RISERS ARE TO BE FIRE RATED CONCRERTE ELEMENTS ARE TO HAVE THE SAME FIRE RATING AS ADJOINING FIRE RATED PARTITIONS
UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB
CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
A
PRECAST CONCRETE
118mm NOM.
20mm CLEARANCE TO PLASTERBOARD
1800
P1_SM (SMOKE WALL) UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
100 MAX.
TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
TO FIRST FASTENER. DO NOT FIX THROUGH HEAD TRACK
FILL GAP WITH SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
GALV. STEEL DEFLECTION HEAD TRACK FASTENED TO STRUCTURE OVER @ 600mm MAXIMUM CENTRES
FIRE COMPARTMENT WALL - 2 HOUR RATED
GENERAL STUD PARTITIONS
P1 118mm NOM. CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
IW
KEY PLAN
4
D.13 1100 T1FGALS
2
2700
EQ
GENERAL STUD PARTITIONS
20mm CLEARANCE TO PLASTERBOARD
CHECKED
ASL
KEY PLAN
1
TYPICAL WALL
UNDERSIDE OF ROOF CLADDING OR STRUCTURAL FLOOR SLAB
DRAWN BY
06/12/18 DRAWING No
10341 A51-001
FIRE COMPARTMENT WALL - SMOKE
FC1
DATE
A51-002
A51-001 Sections EXISTING WALL
50 MIN 105mm NOM. AIR GAP U.N.O.
SECTIONS 1
22.740 Existing Natural Level
1 East-West Section
2
KEY PLAN
LEGEND OF PARTITIONS
FACADE WALLS
Vale St, Mornington VIC 3931
AMBULANCE BAY
BINC50
Elevation 2
The Bays Healthcare Group
28.200 Level 01 Sill
PROJECT
28.200 Level 01 Sill 28.150 Parapet
EXISTING DOWNPIPE TO BE RETAINED
SCALE: 1 : 100
2 A52-002
27.350 Level 01
30.525 Top of Existing Eaves 30.050 Level 01 Ceiling
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
2567
2700
1500
23.08
1 A52-002
28.150 Parapet
A51-002
W.11
3 A52-002
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
ROOF PLANTER BOXES DELETED
1
LV-01
EX. LEVEL 01
The Bays Healthcare Group
A51-001
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
30.050 Level 01 Ceiling
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
CONTINUOUS BEAD OF SPECIFIED SEALANT FOR ACOUSTIC INTEGRITY
ISSUED FOR CONSTRUCTION
ARCHITECTS
2
2
D
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
22.740 Existing Natural Level
REFER TO CIVIL DRAWINGS FOR FINISHED GROUND LEVEL. DEPTH OF FOOTING TO BE 200mm BELOW LOWEST POINT OF A51-001 GROUND LEVEL TO TO TOP OF FOOTING.
1
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
1100
ELSW1
750 600
COMDD EPOE2
Vale St, Mornington VIC 3931 120
WSICU
ICSM
DRAWING TITLE
MPICUP2
INTERNAL ELEVATIONS 1
BEDICU
150 FFL
300
ICU.005 - ICU-5
A61-001 SCALE: 1 : 50
C
ICU.005 - ICU-5
A61-001 SCALE: 1 : 50
D
ICU.005 - ICU-5
A61-001 SCALE: 1 : 50
ICU.005
SCALE
1 : 50@A1 PROJECT No
DATE
DRAWN BY
CHECKED
06/18/18
ASL
IW
DRAWING No
10341 A65-001
A65-001 Internal Elevations
REVISION
C6
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
920
CGFH
900
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
22.740 Existing Natural Level
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
D.09 1100 T1FGALS
1247
Ele vat ion
DIMENSIONS
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
23.620 Plant Enclosure Slab Level
CARPARK
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
2 A51-001
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
24.000 Ground Floor Level
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
4
COPYRIGHT
STORE
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
3
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
External Window Mark
ICU 6 ICU.012
N
Louvre, Powdercoated Monument
W.X
STAFF STATION ICU.011
CGFH
LV01
CORRIDOR ICU.C02
ICU 3 ICU.003
CGFH
Composite Fibre Cement Sheet
D.09 1100 T1FGALS
Precast Concrete to match existing
FC1
3350
PC1
KEY PLAN
100
DRN ASL
27.350 Level 01
A50-001 External Elevations
100 MAX.
DESCRIPTION ISSUED FOR CONSTRUCTION
28.200 Level 01 Sill
LEGEND:
10341 A50-001
50
REV C1
1
2
3
2
4
KEY PLAN
A51-001
CHST
BR7 BRKTST
PLTS 3000
Keynote
CBR750 CG2100 CGFH CHSC
CHST CHV CLERPCF CLERPCF2 CLERPRC CLERPRN CLSL COMD COMDD
CLSL
HB-1S
Keynote
COMPACTUS 3200x1200_M COMT CT CTBED CTCM CTSHR CUFFE1 DDSS DISAD DISGD DISGOWN DISPD DISSD ELDLNR ELSW2
MCBPFF
N
FSK1 SSK1 PLTW
WV1500
S SS
BH SS 1950
BINC240 BINW240
HB2S
650
EQ EQ
D.18 1940 T2FGAL AUTO
BINSST
669
250 1330
450 WPFH
250 CTSHR
CT
WVFH
BINW50
xC
SERVICE POINTS DISCLAIMER
D.21 970 T1
PHS
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
PSH
EXISTING INPATIENT UNIT EQ
WAP01
F
A65-005
G
D.02 970 T1FGAL
IW.01 IWA 533
WPFH D.01
970 T1FGAL
ISSUED FOR CONSTRUCTION
EQ
D.22 1940 T2FGAL AUTO
E H
WAP01
ARCHITECTS
CGFH
ENS
OFFICE
ENS
ENS
CHSC
C
CHSC
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
1 BED
SBO900
FHR1
xD
AMBULANCE ENTRY
2 ---
Keynote Description
Description
PROJECT
A51-002
Keynote
COMPACTUS 3200 x 1200 MESH
EPJ
DATA OUTLET � TELEPHONE OUTLET Curtain Track - Removable Cassette Type CURTAIN - BEDSCREEN Curtain Track - Ceiling Mounted CURTAIN - SHOWER TALL CUP'D - FIRE EXTINGUISHER DANGEROUS DRUG SAFE � SMALL Dispenser - Antiseptic DISPENSER - GLOVE - 4 SIZES DISPENSER - GOWNS DISPENSER - PAPER TOWEL Dispenser - Soap Lighting - Night Light Recessed LIGHT SWITCH - TWO WAY
EPO3PH EPOC EPOE1 EPRCD EX DP FEWT FHR1
Keynote Description
Description
Keynote
ELECTRICAL - EQUI-POTENTIAL JUNCTION ELECTRICAL � SINGLE 3 PHASE OUTLET ELECTRICAL � SINGLE POWER OUTLET CLEANERS ELECTRICAL � SINGLE ESSENTIAL POWER OUTLET ELECTRICAL - RESIDUAL CURRENT DEVICE
GR11A HB1 HB1S HB2 HB2S HB-1
FIRE EXTINGUISHER � WATER Fire Services - Fire Hose Reel Type 1 Sink - Flushing Rim Sink Integral Type 1 (square) Floor Waste GRABRAIL - PATIENT SHOWER GRABRAIL TYPE 6 GRABRAIL ASSISTED WC HINGED
FSK1 FW GR6 GR11
HB-1S HB-2S HB-EHI
Keynote Description
Description
Keynote
GRABRAIL - HINGED WITH TOILET ROLL HOLDER & NURSECALL HANDWASH BASIN - STAFF SCRUB WITH LEVER HANDLES HANDWASH BASIN - STAFF SCRUB WITH SENSOR TAP Handwash Basin - Patient & Staff Handwash Basin - Patient with Sensor Tap (ASSEMBLY) HANDWASH BASIN STAFF SCRUB WITH LEVER HANDLES (ASSEMBLY) HANDWASH BASIN STAFF SCRUB WITH SENSOR TAP (ASSEMBLY) HANDWASH BASIN PATIENT & STAFF WITH SENSOR TAP (ASSEMBLY) HANDWASH BASIN ENSUITE HANDED BASIN
HBEHI HK HKE HKIV ICSM IWA IWD IWJ IWP
LMBH M40 MCBPFF
Keynote Description
Description
HANDWASH BASIN - ENSUITE BASIN HANDED Hook - Hat & Coat - Standard Hook - Equipment Hook - Intravenous Fluids INTERCOM - SURFACE MOUNTED INTERNAL WINDOW TYPE A SILL AT FLOOR LEVEL INTERNAL WINDOW TYPE D SILL AT 900 HEAD AT 2100 INTERNAL WINDOW TYPE J - SILL AT 1200 INTERNAL WINDOW TYPE O SILL AT 2100 HEAD AT 2700 BULKHEAD - LAMINATE MIRROR - 400W X 850H Medical Cleaning Equipment - Bed Pan Flusher
Keynote
MDBGA
MDMON MPICUP2 MPRES MPVENT MSP NC OB4sm OB51 PBCB PCPW
Keynote Description
Description
Keynote
MEDICAL DIAGNOSTIC EQUIPMENT - BLOOD GAS ANALYSER MEDICAL DIAGNOSTIC EQUIPMENT - MONITOR MEDICAL PATIENT SUPPORT EQUIPMENT - ICU SERVICES TANDEM PENDANT (WET & DRY) MEDICAL PATIENT SUPPORT EQUIPMENT - RESUS TROLLEY Medical Patient Support Equipment Ventilator Medical Service Panel NURSE CALL BUTTON OB CUPBOARD - WITH DOORS 700H SITE MEASURED LOCKABLE OB CUPBOARD - COUNTER FORM STORAGE 350W BULKHEAD - PLASTERBOARD Patient Pump Storage Pole Wall Fixed
PHS PLTS 3000 PLTW POST PROWD1 PSH PSP PXB PXW REFPHAU ROWO S SS
The Bays ICU Expansion
Keynote Description
Description
Keynote
Plumbing - Handheld Shower Rose Patient Lifting Track System - 3000 Long Track PLUMBING - LEVER TAPS WALL MOUNTED POST - SUPPORT POST PLUMBING - DIALYSIS REVERSE OSMOSIS WATER AND DRAIN ICU SHELF � PROPRIETARY SOAP / SHAMPOO SHELF PLUMBING � SENSOR OUTLET (WALL MOUNTED) PLUMBING � FLICKMIXER BENCH MOUNTED PLUMBING - FLICKMIXER WALL MOUNTED REFRIGERATOR - PHARMACY UNDERBENCH REVERSE OSMOSIS WATER AND DRAIN PLATE SHELF STAINLESS STEEL
SBO900 SH-PA
SPJICU3 SSK1 STOWBA1 STOWBA2 T1 T1 EXIST T1FGAL T1FGALS T1FGALS EXIST
Keynote Description
Description
Keynote
SPIRIT / WHITE BOARD - 900 LONG X 1200H (ASSEMBLY) SHOWER PARTIALLY ASSISTED Pathology Bay Special Joinery Sink - Integral Stainless Steel Single Bowl 250 Deep Basket Storage Layout A Starter Bay 475w X 635D Basket Storage Layout A Add-on Bay 445w X 635D Door - Single Leaf Door - Single Leaf Door - Single Leaf Fully Glazed Aluminium Leaf DOOR - SINGLE LEAF FULLY GLAZED ALUMINIUM LEAF SLIDING DOOR - SINGLE LEAF FULLY GLAZED ALUMINIUM LEAF SLIDING
T1G T2 T2 EXIST T2FGAL T3 EXIST T3G TL5DR TLAIR
TLICUB TLIV TLLNCS TLLND TVBC TVLCD32CM TVLCD44
Vale St, Mornington VIC 3931
Keynote Description
Description
Door - Single Leaf Glazed Panel Door - Double Leaf Door - Double Leaf Door - Double Leaf Fully Glazed Aluminium Leaf Door - Cat and Kitten Door - Cat and Kitten Glazed Panel TROLLEY - 5 DRAWER TROLLEY - AIRWAYS / DIFFICULT INTUBATION TROLLEY - ICU BEDSIDE Trolley - IV Fluids TROLLEY - CLEAN LINEN SMALL TROLLEY - LINEN DIRTY TV Ceiling Bracket TELEVISION - FULL HD TV 32" CENTRAL MONITOR TELEVISION - LCD FULL HD TV 44"
Keynote
UB1sm UB4sm UB12 UB15
Description
DRAWING TITLE
UB UNIT WITH SINGLE DRAWER SITE MEASURED WIDTH UB CUPBOARD WITH DOORS SITE MEASURED
FITOUT PLAN
UB UNIT � WITH 4 BASKET DRAWERS 450W UNDERBENCH LEG � STAINLESS STEEL UNDERBENCH STAINLESS STEEL SHELF TOILET - FULLY ASSISTED CONCEALED CISTERN (ASSEMBLY) Toilet - Standard Toilet - Standard Concealed Cistern WORKSTATION - 1800 X 800DP Work Station ICU WORKSTATION � UNDERBENCH 3 DRAWER MOBILE UNIT
UBLEGSS USS WC-FAC WCS WCSC WS188 WSICU WSUB2
SCALE
1 : 50@A1
DATE
DRAWN BY
CHECKED
06/05/18
ASL
IW
DRAWING No
PROJECT No
REVISION
C4
10341 A61-001
CURVED GLAZED SCREEN
CURVED GLAZED SCREEN
KEY PLAN
1800
2
B
A51-001
450
8
600
UB15 UB15
798
Elevation B
A61-001 SCALE: 1 : 20
CHSC
CLERPCF2
SKCV
350
350
601 EQ
1400
DESCRIPTION
DRN
DATE
ISSUED FOR CONSTRUCTION INTERNAL ELEVATION ROUGH IN ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION
ASL
24/10/2018 03/01/2019 15/01/2019 07/03/2019
ASL ASL
798
693
255
LA-05
CLERPCF2
200
OB51
LA-05
LA-04
WSUB2
LA-04
OB51
CLERPRC
220
522
150
200
200
150
700
480
220
LA-03
70
1815
33
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
1800
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
100
SOL-01
LA-05
720
601
LA-05
LA-04
SOL-01
SERVICE POINTS DISCLAIMER
CLERPRC
FFL
9
WSUB2
150 FFL SPJICU1 Section 2
10
SCALE: 1 : 20
SPJICU1 Section 3
SCALE: 1 : 20
LA-05
ISSUED FOR CONSTRUCTION
UB15 SKCV
THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS.
LA-03
LA-03
LA-03
LA-03
LA-03
A51-001
LA-03
1050 950
720 WSUB2
2
SPJICU1 LA-04
SPJICU1
950
79
1050 950
1400
SOL-01
TVLCD32CM
OB51
R
1400
LA-04
SPJICU1
05/03/2019 Staff Station
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
693 CURVED GLAZED SCREEN
1800
SOL-01
1050 950
09/04/19 Ceiling & Feature Skylight Works
DIMENSIONS
220
CURVED GLAZED SCREEN
1400
A71-001
05/03/2019 Completed External Facade
COPYRIGHT
WSUB2
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
220
Elevation D
1800
15/01/2019 Precast & Structural Steel Works SOL-01
COMDD
CHSC
A71-001
10
450
OB51
A61-001 SCALE: 1 : 20
CHSC
CLERPCF2 WSUB2
350
UB15
UB15
350 350
601
OB51
COMDD
CHSC
25mm RADIUS TO CORNER
C
350
OB51
350
LA-03
150 FFL
20 0
350
OB51
OB51 LA-04
4572 OB51 OB51
TL5DR
20 0
200
R
REV C1 C2 C3 C4
COMT
LA-05
00 R1
SCALE: 1 : 20
385
TVLCD32CM
WSUB2
D
385
CBR750
OB51 LA-04
SOL-01
Elevation C
0 R 12
350
200
SOL-01
° .31 73
SPJICU1 Plan
511
COMT
720 600
LA-01
UB15
1
UB15
EQ
CLERPCF2
SPJICU1
450 70 450
WSUB2 TVLCD32CM WSUB2
9
UB15
1450
825
SPJICU1
A61-001 SCALE: 1 : 20
A71-001
UB15 SKCV
255
1050 950 900
A71-001
350
EQ
SOL-01
SOL-01
A
SKCV
825
CBR750
350
OB51
770
4687
TL5DR
4574
5536
B
10
SKCV
511
350
1
A71-001
A71-001
450
LA-03
A61-001 SCALE: 1 : 20
CURVED GLAZED SCREEN
A51-001
C
450
1800
OB51
TL5DR
UB15 SKCV
Elevation A
A51-001
A71-001
50
SOL-01
UB15
150 FFL
UB15
9
2672
SOL-01
SOL-01
280
11.52 TOUGHENED AND LAMINATED GLASS TO AS1288 CURVED AS SHOWN
50
A71-001
UB15
1
450
N
R1 20
885
R 20 0
CLERPRC
A71-001
SPJICU1
1050 950
LA-01
10 6.6 9°
30
1400
601
.31 °
700
73
C
20 0
200
8
1450
A71-001
SOL-01
SOL-01
R1 00
720
R
05/03/2019 Corridor for ICU bays 1, 2 & 3
The Bays Healthcare Group
SBO900
A61-001 Fitout Plan B
18/11/2018 General Demolition & Excavation
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
1 BED
BED
CLERPRC
BC3
BC3
CLERPCF
WS188 CLERPRC
DDSS
WSUB2
B
A65-004 A61-002
WPFH
D
CLERPCF
B
HK
A65-004
C
BH L 2100 700dp
CHV
A.ICU.020 CARPET A 9.6 m²
A
D
WSUB2
WS188
OFFICE
A.ICU.019 CARPET 9.6 m²
CHV
HK
B
250 BINW20
ASB
Keynote Description
Description
CANTILEVER BRACKET � 750DP BENCH CORNER GUARD 2100 HIGH FULL HEIGHT CORNER GUARDS CHAIR - STAFF CLERICAL ERGONOMIC MEDIUM BACK CHAIR - STOOL CHAIR - VISITOR CLERICAL � FLAT SCREEN AND PC CLERICAL - 2No. FLAT SCREENS AND PC CLERICAL - COMPUTER PRINTER / SCANNER / COPIER CLERICAL - COMPUTER TERMINAL PRINTER - NETWORK (STATE) CLOCK - TIME (SLAVE - MASTER) DATA OUTLET � GENERAL DATA OUTLET � DOUBLE
WPFH
BPR6/d
COMPACTUS 3200x1200_M
R
TVLCD44 WSICU
880
IW.19 IWA 960
BINW20
15 0
CLERPCF2 OB4sm OB4sm OB4sm OB4sm OB4sm
CLERPRC
UB12 WVFH
1150 COS
570 HB-2S
CHV
A A65-003
A.ICU.018 FV 8.1 m²
350
WPFH
CUFFE1 625
WVFH CGFH
UB12
CHSC
CLERPCF2
CHSC
CLERPCF2
620 HBEHI BINW20 WVFH
350
WPFH
WPFH
BINW20
ASB
HB-2S 450
800
CLERPRC
UB15 UB15 TL5DR TL5DR
TVLCD32CM WSUB2 WSUB2 SPJICU1
TL5DR UB15 UB15
WSUB2
D 97 .04 0T 1
E 3
50
IW.04 IWA 1533
C
CBR750
GR6
CGFH
A.ICU.025 FV 21.0 m²
REFPHAU FW SH-PA PHS GR6 PSH
FW SH-PA
A.EXT.002 FVAS 2.7 m²
CHV
550
FEWT
B
C
WPFH
CORRIDOR
MEDICATIONS
CTSHR
WVFH
A A65-003
WC-FAC
730
INTEGRAL VENETIANS
Keynote Description
Description BOOKCASE FREESTANDING WITOUT DOORS BED - INTENSIVE CARE BED � PATIENT SINGLE ELECTRIC BENCH HIGH LAMINATE FINISH BENCH HIGH - STAINLESS STEEL Bin - Clinical Waste 50 Litre Bin - Clinical Waste 240 Litre BIN - SHARPS DISPOSAL SMALL, TROLLEY MOUNTED Bin - Waste 20 Litre Bin - Waste 50 Litre Bin - Waste 240 Litre Rack - Bed Pan (6 pans) with Drip Tray Rack - Bottle (7 bottles) BRACKET - SHARPS DISPOSAL, TROLLEY MOUNTED
EQ
670
HB-EHI
SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.
UPS
CLEANER
defecting photos
BINW20 BINW50 BINW240 BPR6/d
1491
BINC50
TLICUB
INTEGRAL VENETIANS
EQ
D
ENS
A.ICU.015 SRV D 5.0 m²
HK
FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS
25 0 D.17 970 T1
WVFH
---
B
D.03 970 T1FGAL PROXY
STOWBA1
GR11
A
1 A24-003
STOWBA2
-
D.16 920 T1G INTERLOCK
DIMENSIONS
USE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE.
construction photos
Keynote Description Keynote
BINSST
250
---
C WPFH
BINW20
GR11A
HK WVFH
BINC50
C
A65-003
BINW20
A.ICU.014 600 FV 4.0 m² HB-2S B
STORE
STORE
CTBED
WSICU
B
A65-003
B
WC-FAC
A65-003
COPYRIGHT
ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT.
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
BEDICU
FB
A
A65-003
A.ICU.017 SRV 7.0 m²
WVFH
D.05 2150 T1FGALS
C
TLAIR WPFH
CTCM
B
A65-001
TVLCD44
MPICUP2
INTEGRAL VENETIANS
A51-002
TLLND
D
PAT ENS C
HK HK
MPRES
250 INTEGRAL VENETIANS
D
RO OUTLET
BEDICU BEDPATE BH L BH SS BINC50 BINC240 BINSST
CGFH
A.ICU.016 FV 1.5 m²
A
CUFFE1
BAY-HB
IW.06 IWA 983
WPFH WVFH
A6 5-00
400
250
IW.07 IWA 900
IW.09 IWA 2124
C
PSP HB-1S
A.ICU.013 FV D 0.9 m²
1 A71-002
1262 HB-1S
ANTE
DISGOWN
D
ASB
INTENSIVE CARE UNIT CGFH
A
A.ICU.001 FV 24.4 m²
OB51 OB51
IW.10 IWA 600
A.ICU.024 FV 23.7 m² G
B-RESUS
1200
2
F
A65-005
A71-001
TXD 800 T1 EXIST
PLANT HB 250
BINC50
DATE
24/10/2018 03/01/2019 18/03/2019 09/04/2019
COMMS
A.EXT.001 FVAS 1.8 m²
RO OUTLET
998 1400
NEGATIVE PRESSURE IW.20 CLSL IWJ 800
xB
LOW LEVEL EXHAUST - SETOUT TO EDGE OF BEAM ABOVE
0 15
BEDICU
2702
WAP-02
E H
C
1201
D
R
A.ICU.012 --FV 24.1 m²
D.15 920 T1G INTERLOCK
D.20 970 T1
CGFH
ICU-6-ISO
CHST
B
A65-002
CGFH
B
A65-001
D
A71-001
A D
D.13 1100 T1FGALS
ICU-1
250
1700
A
670
ICU-2
D.06 1800 T1FGALS
CHST
BEDICU
FB
A.ICU.002 FV 25.0 m²
D
2150
1570
WSICU
IW.08 IWA 820
BINW20
725
TVLCD44
230
RO OUTLET
INTEGRAL VENETIANS
HB-1S
CORRIDOR
BINC50
CTCM
BINSST
CLSL TLICUB
B
A71-001
IW.12 IWA 600
BINC50
OB51 OB51
D.07 1800 T1FGALS
855
B
A71-002
A.ICU.011 FV 22.8 m²
ASL ASL
EXISTING INPATIENT UNIT WAP01
0 R 25
B
A65-002
DRN
ASL
CGFH
TLICUB
MPICUP2
A D
DESCRIPTION
ISSUED FOR CONSTRUCTION INTERNAL ELEVATION ROUGH IN ISSUED FOR CONSTRUCTION ISSUED FOR CONSTRUCTION
WAP01
PLTS 3000
250
C1 C2 C3 C4
ENS
ENS
BINW20
WPFH
B
A65-002
REV
ENS
WV1500
CG2100
CTCM
WAP-02
STAFF STATION
A.ICU.007 FV 9.6 m²
IW.18 IWA SM DG1
D.14 2000 T2FGAL
UB4sm UB1sm SPJICU3 MDBGA
CHST
980
OB51 OB51
IW.13 IWA 2124
TVLCD44
CHST
B
1690 HB-1S
ASB
CTCM
250
INTEGRAL VENETIANS
C BINW20
ASB
MPICUP2
250
A65-001
230
250
TLLND
1200
E
C
1 A71-001
CTCM
D
ICU-3
A.ICU.003 FV 25.0 m²
IW.11 IWD 1420
TLLND
PLTS 3000
LANDSCAPING TO BE DETERMINED BY CLIENT
C
150 FFL
8
UB15
LA-03
ARCHITECTS
SPJICU1 Section 1
SCALE: 1 : 20
ABN: 73 561 269 057 3 GLENARM ROAD, GLEN IRIS, VICTORIA 3146 PH: (03) 9885 2333 FAX: (03) 9885 2455
FRONT EDGE OF DESK
720
NOTE: AS NOTED IN THE SPECIFICATIONS, ALL EXPOSED JOINERY EDGES ARE TO BE SEALED
RAISED HOB
EDGE OF BENCHTOP
1700
THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION CLIENT
875 OVERALL BENCH DEPTH
CURVED GLAZED SCREEN, FIXED INTO 70mm X 25mm ALUMINIUM CHANNEL. SCREEN TO BE EMBEDED MININUM OF 40mm DEPTH, AS PER MANUFACTURER'S REQUIREMENTS
The Bays Healthcare Group SOLID SURFACE HOB SOL03
210
1000
SOL03
50
1050 SOLID SURFACE SOL03
LAMINATE LA04 TO RECESSED PANEL ABOVE BENCH POWER AND DATA SERVICES CAVITY (70mm APPROX)
PROJECT
The Bays ICU Expansion
OB51 LA05, WHERE APPLICABLE
Vale St, Mornington VIC 3931
POWDERCOATED CANTILEVERED BRACKET, COLOUR `BLACK'
LAMINATE LA03 TO INSIDE FACE
950
POWDERCOATED CANTILEVERED BRACKET, COLOUR `BLACK'
LAMINATE LA03 TO INSIDE FACE
CLEAR
1050
50
DRAWING TITLE
SPECIAL JOINERY 1
SOL03
710
COVED SKIRTING
3
COVED SKIRTING
20
150
SCALE
FFL
SPJICU1 View 2
SCALE:
7
SPJICU1 - TYPICAL SECTION
SCALE: 1 : 10
A71-001 Special Joinery - SPJ01
20 100 20
CL
11
SPJICU1 Perspective
SCALE:
DATE
DRAWN BY
CHECKED
As indicated@A1
06/28/18
ASL
IW
PROJECT No
DRAWING No
10341 A71-001
REVISION
C4
C:\Users\aliang\Documents\BAYS_BUILDING_A18_aliang8M3R9.rvt
UB 15
BE
33MM THICK LAMINATE LA05 BENCH TOP
20
YO ND
SCALE:
100
SPJICU1 View 1
330
2
720
selected sheets from construction set
250
DIRTY UTILITY
D.12 920 T1G
1 BED
1 BED
HKIV
C
FIRE EXTINGUISHERS UNDER BENCH
B CGFH WPFH
A65-002
A.ICU.010 FV 1.5 m²
A
A.ICU.009 FV D 1.0 m²
B
A65-002
BAY-PATH CLERPRN C
549
BINSST BEDICU
FB WSICU
INTEGRAL VENETIANS
2
G
A71-001
A
A50-001
F
A65-004
250
R
A51-001
BC3
A.ICU.023 H FV 29.4 m²
CGFH
0 25
PLTS 3000
INTEGRAL VENETIANS
1200
1
CLSL TLICUB
MPICUP2
250
WPFH
E
CORRIDOR
2 A24-003 WPFH CGFH WPFH
D
A.ICU.008 FV 1.6 m²
WPFH TLLNCS
BAY
A
BAY-HB
WPFH CGFH
CBR750
1 A51-002
WPFH
IW.17 IWA 1300
3050
D.11 1490 T3G
WVFH HB-1S CG2100WPFH
1 BED
B
A65-002
WPFH
WPFH
ASB BINW20
B
A65-002
C
UB12
500
BINC50
CTCM
D.10 1800 T1FGALS
WPFH
3050
B
ICU-5
A.ICU.005 FV 24.1 m²
IW.15
D.08 1800 T1FGALS
D
BINW50
CHST
TVLCD44
300 IWA 1250
450
249
CTCM
A
WSICU
D.09 1100 T1FGALS
800
ICU-4
A.ICU.004 FV 23.8 m² IW.14 IWA 1300
CLSL
B
A65-001
C
TVLCD44
WPFH
A D
C
HB-1S
800 HB-1S
B
A65-001
CHST
INTEGRAL VENETIANS
3
D
WSICU
ASB
BINW20
A D
A.ICU.006 FV 21.3 m²
PCPW
TLICUB
800
A
BINC50
A50-001
150 IW.16 IWA 547
150
EXISTING
FW
CLEAN STOCK
PCPW
ACR
CLSL
BINSST
xA
EX FHR
A.ICU.021 CARPET 3.0 m²
WPFH HKE HKE HKE HKE
TLIV PLTS 3000
249
10
CGFH
TLIV
250 BEDICU PLTS 3000
TLICUB
SITTING
A.ICU.022 FVAS 2.5 m²
WPFH
CGFH
MPVENT
BEDICU
BINSST
EDB
MPVENT
WPFH
MPVENT
MPICUP2
WVFH
WPFH
TLLND
25 0
SPJICU2
R
UB12
0 25
MPICUP2
250
UB12
R
1200
TLLND
PLANT ENCLOSURE
UB12
11
250
A
250
D.19 1640 T2
concept ideas & interior finishes
acrylic splashback
»» ICU Bays »» Handbasin Bays
timberlook vinyl flooring
»» ICU bays floor inserts
joinery & door finish
»» doors »» standard joinery
wall cladding
»» staff station
vinyl flooring
»» general floor vinyl
benchtop laminate
»» staff station »» medications
aluminium finish
»» door frames »» window frames
internal carcase
»» staff station »» medications
solid surface
»» staff station
writable glass
»» staff station
benchtop laminate
»» staff station »» office
wall paint finish
»» general wall paint finish
Driftwood
Elephant Rock, Mornington Penninsula
Staff Station Render - SPJ01
ICU Bay 2 Render
»» pathology bay
»» pathology bay
2.0 academic work
2.1
design studio: air
Design Studio: Air was a second year undergraduate subject that aimed at exploring of the way technology enables us to reimagine how we imagine architectural form. Part one of the design studio comprised of a research project in which we observed and reflected upon how parametric design is used in design and its future role for new architectural typologies as well as considering ideas such as manufacturing and constructability. It also required students to develop a technical understanding of how to manipulate forms in grasshopper. The exercises below showcase using a real world example and reverse engineering the form in a Grasshopper sequence. The second exercise was to develop and experiment using the reverse engineer sequence to generate an entirely new geometry.
reverse engineering of Kings Cross Station canopy by John McAslan Partners
furthering technical development
2.1
design studio: air
Part Two of the design studio was to create an enclosed virtual environment in which people can experience an augemented reality. The aim of my design was to illustrate the environmental degradation of national parks such as Merri Creek, our site for the museum walk, by using the natural landscape and slowly melding with artificial and unnatrual geometries. My concept utilised the grid shell from earlier in the studio to create a canopy design that would mimic tree top canopies as a means of safety, security and refuge.
concept experiential story board
view 1 - a walk in the park
canopy geometry
view 2 - a shadowy corridor
view 3 - something’s amiss
view 4 - less nature
augmented reality trail
view 5 - natural or artificial
view 6 - nothing organic
key views
1 2 3 4 5
2.2
construction design
Construction Design serves as the third year culmination of the preceding construction subjects. In this subject students are asked to inpret a set of Architectural, Structural and Surveying packages. The purpose of this subject is to be able to visualise from two dimensional drawings into three dimensional outputs, understanding architectural designs in terms of constructability, understanding construction processes and developing model making skills. The first exercise is to redraw an allocated section at 1:20 in an axonometric format making callouts to specific components of the design, structure or details. The second exercise is to build a physical 1:20 scale model of the allocated section with revealed areas to show details of construction in a three dimensional environment. Both of these exercises are to be completed individually.
A
A) Roof parapet cladding & curtain wall
B
Axonometric Drawing
Physical Model, Perspective 1
B) Level 1 Curtain wall
C
F
H
E D G
Physical Model, Perspective 2
C) Level 1 beam to column to slab connection
D) Section through ground works showing mass concrete, footings, rebar, waterproofing, formwork, ground floor slab & ground floor finishes
Physical Model, Perspective 3
Physical Model, Perspective 4
E) Section through soil showing Red-Brown for Clay Silt, Light-Brown for Weathered Basalt, & Dark-Grey for Weathered Basalt
G) Cutaway showing Carpet, Screed, Hydronic Heating & Rebar
F) Section through airlock roof structure
H) Section through L1 hollowcore slab & beam
2.3
design studio: fire
Design Studio: Fire is the capstone design subject which is intended to incorporate the knowledge and expertise students have gained in previous coursework. The aim of the subject is to allow students to interpret a brief and develop an appropriate design response in an urban context. In this case, the studio brief was to design a learning centre equipped with sport facilities, a library, study spaces and general classrooms. The site of the project was an extension of the University High School Campus, opposite the University of Melbourne. My interpretation of the brief was to create a learning centre that focused on multi-disciplinary or interdisciplinary learning attitudes that reflected the requirements of the brief. The ideas of my project were as followed: »» »» »» »» »» »»
Multi-Faceted Learning Opportunities Comprehensive Learning Environments Distinctive Departmentalisation Simplistic Wayfinding Community Integration Independent & Cooperative Study
Rendered Site Analysis by Zoning with Proposed Design Overlay
Site Analysis by Zone
Site Analysis by Building Height
design studio: fire
A
administration
A
floor plans
quiet study & project rooms
2.3
library
lec
air
tur
he
e ntr Ground Floor
A
ll
ma
in s
rts
ce
n
ge
b
we
ll
o sro
las
c ral
ne
ge
sp o
cla
ms
ea bo ve
l era
r la
e
tlin
o
o ssr
ute
atr
ou
ms
mp
air
we
et
co
Level 1 Floor Plan
e
ac
A
o
tdo
ou
rr r te
Level 2 Floor Plan
tad
ium
section & internal renders
2.3
Project Rooms & Quiet Zone
Section A.1
design studio: fire
Spectator’s from Cooperative Study Floor
section & internal renders
2.3
Main Stadium / Indoor Court
Section A.2
design studio: fire
Library & Quiet Zone
3.0 personal work
3.1
oils & acrylic
This section is compromised of personal oil or acrylic based artworks that were completed as gifts or for personal collection.
park bench, oil on canvas
lamp, oil on canvas
seas, oil on canvas
oil on canvas
mountain lake i, oil on canvas
mountain lake ii, oil on canvas
lamp ii, oil on canvas
3.2
watercolour
This section is compromised of personal water based artworks that were completed as gifts or for personal collection.
storm, watercolour on paper
moonlight, watercolour on paper