VARIABLE FREQUENCY

DRIVES

Solutions for HVAC Fan, Pump & Cooling Tower Applications


We respond.

And that’s got people talking High Reliability Simple Installation

“Once we’re up and running, we never have to go back to the job site. The 5 year warranty in fan and pump backs it up.”

“Auto-tuning takes all the guesswork out of set up. We don’t need factory commissioning agents any more. “

Fast Shipment

Packaged Solutions “We needed a VFD with bypass the next day. Cerus turned it around.”

81% of our customers enthusiastically recommend Cerus to a friend.

“They built it to meet our specs--working with their in-house engineering gave us the edge.”

SAFETY FIRST!

As with all electrical equipment, only qualified, expert personnel should perform maintenance and installation. Comply with all applicable local and national codes and laws that regulate the installation and operation of equipment and read manuals thoroughly. Use only installation manuals and not this sales brochure for installation procedures. It is up to the installer to determine product suitability for a given application. © 2011 Cerus Industrial, Inc. Product improvement is a continual process. Pricing and specifications subject to change without notice. Marketing materials should not be relied upon for technical specification. Cerus, Mira, Orion, Titan and associated logos are trademarks of Cerus Industrial, Inc. All sales subject to Cerus Terms and Conditions.


P Series

7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Sensorless & VF Control, Integrated PID Control Horsepower Range

1~400HP (200~230V only up to 40 HP)

Voltage Ratings

Input

3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)

Output

3Ø, 200~230V 3Ø, 380~480V

Frequency Ranges

pg 6

Input

50-60Hz

Output

0-120Hz

GS Series 0.5–5HP 200~230VAC, 380~480VAC, 3Ø Dual Rated for Constant & Variable Torque Sensorless & VF Control, Integrated PID Control Horsepower Range

1/4~5HP

Voltage Ratings

Input

3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)

Output

3Ø, 200~230V 3Ø, 380~480V

Frequency Ranges

pg 16

Input

50-60Hz

Output

0-400Hz

Cooling Tower Controls pg 22 Single point Connection Cooling Towers Stand alone or Slave Operation Options Scalable to meet any application Horsepower Range

1~400HP

Voltage Ratings

Input

3Ø, 200~230V (+10%, -15%) 3Ø, 380~480V (+10%, -15%)

Output

3Ø, 200~230V 3Ø, 380~480V

Frequency Ranges

Input

50-60Hz

Output

0-120Hz

Reactors, Filters, and Sensors Optimized Line Reactors Drive Output Reactors & Filters Gage Pressure Sensors Differential Pressure Transducers

pg 34


P Series

ENERGY SAVINGS

Flying Start Protection

Automatic Energy Savings

Space Vector Control

800.962.3787 | FAX: 503.643.4925 | www.cerusind.com


ENERGY SAVINGS for Fans & Pumps. Backed by an Unprecedented 5-Year Warranty. Optimized for Fans & Pumps Everyone knows variable frequency drives (VFDs) can save you money by varying motor speed to match demand. But ramping up and down is just the beginning of energy savings with Cerus.

When you couple all of these protective features with rugged construction, it’s easy to see why we aren’t afraid to back our drives with a 5-year warranty in variable torque applications.

Our automatic energy saving Damper Control mode minimizes energy losses with varying loads Conventional by optimizing flux control inverter control for higher efficiency. In PID mode, sleep and wake up functions can deactivate Titan P-Series the inverter under low demand conditions and wake it up when demand rises for additional savings. It also extends the life of the motor and drive.

So easy to set up, you don’t have to pay for factory commissioning

And space vector modulation gives you a super clean sine wave—much better than a typical VF drive. And that translates to cooler running motors, less losses, and a better system.

Reliability Backed with a 5-Year Warranty Just because our drives are soft on energy, doesn’t mean they aren’t rugged. Check out our high torque ratings— they’re up to the task. And our VFDs are loaded with features that keep them online. They’re able to preheat windings in damp conditions to prevent costly motor and inverter damage. Since power is never perfect, we use the inertia of the load to regenerate power to keep the drive riding through sags. Starting into a spinning fan? No problem. Flying start protection matches the drive to the load for smooth, trip free starts.

Our parameters are straight forward. Keypads are intuitive. Fact is, once you’ve set one up, you’re hooked. Auto tuning takes all the guesswork out of commissioning for fans and pumps.

Engineered for HVAC applications Delivered on time to meet the demands of your project schedule True 3-contactor bypasses for critical applications. Or better, fully redundant duplex panels so that one drive picks up right where the other left off—keeping duct work intact and tenants comfortable. Or just keep it simple; we offer costeffective drive/disconnect packages as well. Line reactors, filtering, we do it all. Rainproof, air conditioned, water proof enclosures. We know what outdoor installations call for and we’ll deliver the goods competitively and quickly. Our cooling tower packages deliver reliability, ease of installation and energy savings. We incorporate all the functionality into a single, clean, rugged panel. The net result is a compact control that’s easy to install. Just one power source for reduced installation costs, easy operation, and a job well done.


VARIABLE FREQUENCY DRIVES

P-Series VFD

7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Space Vector control for efficiency and long motor life Cleaner sine wave as compared to typical V/Hz control. Motors run cooler and last longer

Advanced PID control (Pre-PID and Dual PID)

Maintain a constant control of pressure, flow or water level. This function includes Pre-PID, Sleep and Wake up and output inverse sub-functions Dual PID for external PID control or cascade PID control Multi-Motor

Multi-motor control function Control up to 4 motors

The 32-character backlit LCD screen displays the drive’s operational status and parameter settings. A very easy drive to set up.

Automatic energy savings mode Adaptive flux control for varying loads (e.g. damper loading)

Sleep and wake up function Increased energy savings by deactivating drive during low demand

Flying start protection Prevents trips, rough starts, and drive damage from regenerative power from heavy fan inertia rotation

Flux braking algorithm Reduces deceleration time for enhanced system efficiency

Pre-heater function Used to protect motor and inverter from damage when installed in damp location (e.g. green house).

6

www.cerusind.com 1.800.962.3787

The P-Series’ clearly marked terminal inputs and outputs allow for easy wiring and setup.


VARIABLE FREQUENCY DRIVES

Automatic carrier frequency change Adjusts based on temperature for optimal operation

Selectable V/F, Sensorless vector control Ideal for any control requirement

Long-life condenser & simple framework Increased reliability

Energy Savings that makes an environmental difference with every building.

Built-in Modbus RTU communication Optional: Profibus-DP, LonWorks, BACnet, Modbus *

Perfect for fans, pumps and airhandlers.

Specifications Output ratings Input ratings

Operation

Voltage (V) Frequency (Hz) Voltage (V) Frequency (Hz) Input Power Factor Drive Efficiency Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Multi-function input terminals Analog output

Three phase, 200~230V, Three phase, 380~480V 0~120Hz Three phase, 200~230V (-15%, +10%), Three phase, 380~480V (-15%, +10%) 50~60Hz (±5%) <.95 from no load to full load >96% V/F control, Sensorless vector control Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.06Hz at 60Hz Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency Linear, Square, User V/F 1 minute at 120%, 10 seconds at 150% (with inverse characteristic proportional to time) Auto, Manual (0~15%) Total 8 inputs (programmable) 0~10V linear

LCD keypad, Terminals, ModBus-RTU communication Operator control 32-character Optional, ProfiBus-DP, DeviceNet, F-Net, BACnet, LonWorks Frequency setting Analog: 0~10V, 4~20mA, additional port for Sub-Board (0~10V); Digital: Keypad, Communication Start signal Forward, Reverse Multi-step operation Setting up to 17 speeds (using multi-function terminal) Input signal

Multi-step accel/decel time 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, functions Auto restart, Inverter bypass, Auto-tuning, Dual PID control Emergency stop Auto operation Jog Fault reset

Output signal

Stops output from inverter Operates from internal sequence by setting multi-function terminal (5 way x 8 step) Jog operation Resets fault signal when protective function is active

detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Operational status Frequency Speed search, Fault output, Inverter bypass, Auto-operation sequence Indicator Output frequency, Output current, Output voltage, DC voltage, Output torque (output voltage: 0~10V)

Protective functions

Operating environment

Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, Fuse open, Ground fault, Trip Overvoltage, External fault 1, 2, Option fault, Overload, Speed command loss, Hardware fault, Communication error, etc. Alarm Ambient temperature Storage temperature Humidity vibration Altitude Application site

Stall, Overload Temperature sensor fault -10°~40° C (50° C when derated 20%) or 14°~104° F (122° F when derated 20%) -20°~65° C or -4°~149.5° F Less than 90% Relative Humidity maximum (non-condensing) Below 5.9m²/sec (=0.6g) Below 1,000m (3,300ft): Derate VFD by 10% for every additional 1,000m Pollution degree 2. No corrosive gas, combustible gas, oil mist or dust

7


VARIABLE FREQUENCY DRIVES

P Series Wiring

*For general reference only, not field wiring. Consult installation instructions.

8

www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

Options Part Number

Description

CI-RKPK-EXT2M-P/S

Remote Keypad Mounting Kit (2 Meter Cable)

CI-RKPK-EXT3M-P/S

Remote Keypad Mounting Kit (3 Meter Cable)

CI-RKPK-EXT5M-P/S

Remote Keypad Mounting Kit (5 Meter Cable)

CI-R4-COM

RS485 communication card

CI-BN-COM

BACnet communication card

CI-LW-COM

Lonworks communication card

CI-N2-COM

N2 communication card

3-Phase, 200~230V P-Series VFD Standard Duty (VT)

Heavy Duty (CT)

Part Number

3% Line Reactor*

2.5

CI-001-P2

KDRULA25LE01

HP

kW

FLA

HP

kW

FLA

1

1.9

5

0.4

0.95

2

3

8

0.75

1.9

5

CI-002-P2

KDRULA27LE01

3

4.6

12

1.5

3

8

CI-003-P2

KDRULA28LE01

5

6.1

16

2.2

4.6

12

CI-005-P2

KDRULB22LE01

7.5

5.5

24

5

3.7

17

CI-007-P2

KDRULB23LE01

10

7.5

32

7.5

5.5

23

CI-010-P2

KDRULD25LE01

15

11

46

10

7.5

33

CI-015-P2

KDRULD24LE01

20

15

60

15

11

44

CI-020-P2

KDRULD26LE01

25

18.5

74

20

15

54

CI-025-P2

KDRULC22LE01

30

22

88

25

18.5

68

CI-030-P2

KDRULF24LE01

40

30

115

30

22

84

CI-040-P2

KDRULF25LE01

Part Number

3% Line Reactor*

* Line Reactors housed in separate UL Type 1 Enclosure

3-Phase, 380~480V P-Series VFD Standard Duty (VT) HP

kW

FLA

1

2

2

3.2

3

4.8

Heavy Duty (CT) HP

kW

FLA

2.5

0.4

1

1.25

CI-001-P4

KDRULA8LE01

4

0.75

2

2.5

CI-002-P4

KDRULA1LE01

6

1.5

3.2

4

CI-003-P4

KDRULA2LE01

5

6.4

8

2.2

4.8

6

CI-005-P4

KDRULA3LE01

7.5

5.5

12

5

3.7

8

CI-007-P4

KDRULA4LE01

10

7.5

16

7.5

5.5

11

CI-010-P4

KDRULA5LE01

15

11

24

10

7.5

17

CI-015-P4

KDRULB2LE01

20

15

30

15

11

22

CI-020-P4

KDRULB1LE01

25

18.5

39

20

15

28

CI-025-P4

KDRULD1LE01

30

22

45

25

18.5

34

CI-030-P4

KDRULD2LE01

40

30

61

30

22

44

CI-040-P4

KDRULC1LE01

50

37

75

40

30

55

CI-050-P4

KDRULF2LE01

60

45

91

50

37

66

CI-060-P4

KDRULF4LE01

75

55

110

60

45

80

CI-075-P4

KDRULF3LE01

100

75

152

75

55

111

CI-100-P4

KDRULH3LE01

125

90

183

100

75

134

CI-125-P4

KDRULH2LE01

150

110

223

125

90

183

CI-150-P4

KDRULH1LE01

200

132

264

150

110

223

CI-200-P4

KDRULG3LE01

250

160

325

200

132

264

CI-250-P4

KDRULG1LE01

350

220

432

250

160

325

CI-350-P4

KDRULJ2LE01

400

280

547

300

220

432

CI-400-P4

KDRULJ1LE01

* Line Reactors housed in separate UL Type 1 Enclosure

9


VARIABLE FREQUENCY DRIVES

P-Series Bypass

7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Drive Isolation Option Indoor & Outdoor Enclosure Options

Standard bypass features Compact vertical design preserves wall space Includes standard MMS disconnect, Hand/Off/Auto & VFD/Off/Bypass switches Fireman’s override/smoke purge ready Choose from 2 or 3 contactor configurations UL 508C rating for maximum motor protection

Wide range of design options

Door mounted control options for manual speed pot, LED pilot lights and more Input circuit breaker Optional installed input or output drive reactors Integrated electronic overload for full phase protection in bypass mode Panel space heaters available for ambient temperatures below 32°F

Installs in minutes, lasts a lifetime.

Enclosure options for any environment A variety of NEMA rated enclosures to meet application requirements (Stainless, fiberglass, watertight, etc.) Dust tight Type 12 enclosures include ducting and ventilation for maximum cooling

10

www.cerusind.com 1.800.962.3787

The easy to use 4-direction keypad makes settings a snap.


VARIABLE FREQUENCY DRIVES Options Description

VFD-RPL*

Run Pilot Light (Green Standard)

VFD-BPL*

Bypass Pilot Light (Amber Standard)

VFD-FLT*

Fault Pilot Light (Red Standard)

VFD-SPD

Door Mounted Speed Potentiometer

VFD-EOL

Solid-state Bypass Overload

VFD-LTA

Lightning Arrestor

CI-BN-COM

BACnet communication card

CI-LW-COM

Lonworks communication card

CI-N2-COM

N2 communication card

VFD-ABYP-R

Drive auto bypass with relay

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

* Select 24V or 120V based on package control voltage. For UL Type 1 select 24V. For UL Type 3R & 12 select 120V.

3-Phase, 200~230V P-Series VFD Bypass Standard duty (VT)

Part Number

Bypass with Drive Isolation (3-Contactor Bypass Equivalent)

2-Contactor Bypass

Line Reactor Options

HP

kW Rating

UL Type 1

UL Type 3R

UL Type 1

UL Type 3R

Installed 3%

Installed 5%

1

1.9

CIE1-BYP001-P2/3

CIE3R-BYP001-P2/3

CIE1-BYP001-P2

CIE3R-BYP001-P2

VFD-KDRA25L

VFD-KDRA25H

2

3

CIE1-BYP002-P2/3

CIE3R-BYP002-P2/3

CIE1-BYP002-P2

CIE3R-BYP002-P2

VFD-KDRA27L

VFD-KDRA26H

3

4.6

CIE1-BYP003-P2/3

CIE3R-BYP003-P2/3

CIE1-BYP003-P2

CIE3R-BYP003-P2

VFD-KDRA28L

VFD-KDRA28H

5

6.1

CIE1-BYP005-P2/3

CIE3R-BYP005-P2/3

CIE1-BYP005-P2

CIE3R-BYP005-P2

VFD-KDRB22L

VFD-KDRB25H

7.5

5.5

CIE1-BYP007-P2/3

CIE3R-BYP007-P2/3

CIE1-BYP007-P2

CIE3R-BYP007-P2

VFD-KDRB23L

VFD-KDRB26H

10

7.5

CIE1-BYP010-P2/3

CIE3R-BYP010-P2/3

CIE1-BYP010-P2

CIE3R-BYP010-P2

VFD-KDRD25L

VFD-KDRD21H

15

11

CIE1-BYP015-P2/3

CIE3R-BYP015-P2/3

CIE1-BYP015-P2

CIE3R-BYP015-P2

VFD-KDRD24L

VFD-KDRD22H

20

15

CIE1-BYP020-P2/3

CIE3R-BYP020-P2/3

CIE1-BYP020-P2

CIE3R-BYP020-P2

VFD-KDRD26L

VFD-KDRC22H

25

18.5

CIE1-BYP025-P2/3

CIE3R-BYP025-P2/3

CIE1-BYP025-P2

CIE3R-BYP025-P2

VFD-KDRC22L

VFD-KDRF28H

30

22

CIE1-BYP030-P2/3

CIE3R-BYP030-P2/3

CIE1-BYP030-P2

CIE3R-BYP030-P2

VFD-KDRF24L

VFD-KDRF25H

40

30

CIE1-BYP040-P2/3

CIE3R-BYP040-P2/3

CIE1-BYP040-P2

CIE3R-BYP040-P2

VFD-KDRF25L

VFD-KDRF26H

3-Phase, 380~480V P-Series VFD Bypass Standard duty (VT)

Bypass with Drive Isolation (3-Contactor Bypass Equivalent)

2-Contactor Bypass

Line Reactor Options

HP

kW Rating

UL Type 1

UL Type 3R

UL Type 1

UL Type 3R

Installed 3%

Installed 5%

1

2

CIE1-BYP001-P4/3

CIE3R-BYP001-P4/3

CIE1-BYP001-P4

CIE3R-BYP001-P4

VFD-KDRA8L

VFD-KDRA8H

2

3.2

CIE1-BYP002-P4/3

CIE3R-BYP002-P4/3

CIE1-BYP002-P4

CIE3R-BYP002-P4

VFD-KDRA1L

VFD-KDRA1H

3

4.8

CIE1-BYP003-P4/3

CIE3R-BYP003-P4/3

CIE1-BYP003-P4

CIE3R-BYP003-P4

VFD-KDRA2L

VFD-KDRA2H

5

6.4

CIE1-BYP005-P4/3

CIE3R-BYP005-P4/3

CIE1-BYP005-P4

CIE3R-BYP005-P4

VFD-KDRA3L

VFD-KDRA3H

7.5

5.5

CIE1-BYP007-P4/3

CIE3R-BYP007-P4/3

CIE1-BYP007-P4

CIE3R-BYP007-P4

VFD-KDRA4L

VFD-KDRA4H

10

7.5

CIE1-BYP010-P4/3

CIE3R-BYP010-P4/3

CIE1-BYP010-P4

CIE3R-BYP010-P4

VFD-KDRA5L

VFD-KDRA5H

15

11

CIE1-BYP015-P4/3

CIE3R-BYP015-P4/3

CIE1-BYP015-P4

CIE3R-BYP015-P4

VFD-KDRB2L

VFD-KDRB2H

20

15

CIE1-BYP020-P4/3

CIE3R-BYP020-P4/3

CIE1-BYP020-P4

CIE3R-BYP020-P4

VFD-KDRB1L

VFD-KDRC3H

25

18.5

CIE1-BYP025-P4/3

CIE3R-BYP025-P4/3

CIE1-BYP025-P4

CIE3R-BYP025-P4

VFD-KDRD1L

VFD-KDRC1H

30

22

CIE1-BYP030-P4/3

CIE3R-BYP030-P4/3

CIE1-BYP030-P4

CIE3R-BYP030-P4

VFD-KDRD2L

VFD-KDRE2H

40

30

CIE1-BYP040-P4/3

CIE3R-BYP040-P4/3

CIE1-BYP040-P4

CIE3R-BYP040-P4

VFD-KDRC1L

VFD-KDRF4H

50

37

CIE1-BYP050-P4/3

CIE3R-BYP050-P4/3

CIE1-BYP050-P4

CIE3R-BYP050-P4

VFD-KDRF2L

VFD-KDRF1H

60

45

CIE1-BYP060-P4/3

CIE3R-BYP060-P4/3

CIE1-BYP060-P4

CIE3R-BYP060-P4

VFD-KDRF4L

VFD-KDRF2H

75

55

CIE1-BYP075-P4/3

CIE3R-BYP075-P4/3

CIE1-BYP075-P4

CIE3R-BYP075-P4

VFD-KDRF3L

VFD-KDRH2H

100

75

CIE1-BYP100-P4/3

CIE3R-BYP100-P4/3

CIE1-BYP100-P4

CIE3R-BYP100-P4

VFD-KDRH3L

VFD-KDRH1H

125

90

CIE1-BYP125-P4/3

CIE3R-BYP125-P4/3

CIE1-BYP125-P4

CIE3R-BYP125-P4

VFD-KDRH2L

VFD-KDRG3H

11


VARIABLE FREQUENCY DRIVES

N1 P-Series Enclosed with Disconnect 1–30HP (200~230VAC), 1–40HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Easy Installation, Time Saving Design

Reduces labor costs Attractive, mated design MMS disconnect Fireman’s override/smoke purge capable UL 508C rating with all drive models for maximum motor protection Optional Input drive reactor, HOA switch, manual speed potentiometer, and communications

Rugged disconnect includes padlock provisions.

The 32-character backlit LCD screen displays the drive’s operational status and parameter settings. A very easy drive to setp up.

Dimensions B

C

A

12

www.cerusind.com 1.800.962.3787

P-Series Drive with Disconnect

H x W x D, (A x B x C)

CIE1-ED001-P2/D ~ CIE1-ED015-P4/D

24.50”x 8.00” x8.12”

CIE1-ED020-P2/D ~ CIE1-ED020-P4/D

32.50” x 9.97” x8.70”

CIE1-ED025-P2/D ~ CIE1-ED040-P4/D

40.00” x 12.17” x 9.97”


VARIABLE FREQUENCY DRIVES

Options Part Number

Description

VFD-HOA

Hand/Off/Auto switch

VFD-SPD

Door Mounted Speed Potentiometer

CI-R4-COM

RS485 communication card

CI-BN-COM

BACnet communication card

CI-LW-COM

Lonworks communication card

CI-N2-COM

N2 communication card

3-Phase, 200~230V P-Series VFD Standard Duty (VT)

Part Number

3% Line Reactor

5

CIE1-ED001-P2/D

VFD-KDRA25L

8

CIE1-ED002-P2/D

VFD-KDRA27L

2.2

12

CIE1-ED003-P2/D

VFD-KDRA28L

HP

kW

FLA

1

0.75

2

1.5

3 5

3.7

16

CIE1-ED005-P2/D

VFD-KDRB22L

7.5

5.5

24

CIE1-ED007-P2/D

VFD-KDRB23L

10

7.5

32

CIE1-ED010-P2/D

VFD-KDRD25L

15

11

46

CIE1-ED015-P2/D

VFD-KDRD24L

20

15

60

CIE1-ED020-P2/D

VFD-KDRD26L

25

18.5

74

CIE1-ED025-P2/D

VFD-KDRC22L

30

22

88

CIE1-ED030-P2/D

VFD-KDRF24L

Part Number

3% Line Reactor

3-Phase, 380~480V P-Series VFD Standard Duty (VT) HP

kW

FLA

1

0.75

2.5

CIE1-ED001-P4/D

VFD-KDRA8L

2

1.5

4

CIE1-ED002-P4/D

VFD-KDRA1L

3

2.2

6

CIE1-ED003-P4/D

VFD-KDRA2L

5

3.7

8

CIE1-ED005-P4/D

VFD-KDRA3L

7.5

5.5

12

CIE1-ED007-P4/D

VFD-KDRA4L

10

7.5

16

CIE1-ED010-P4/D

VFD-KDRA5L

15

11

24

CIE1-ED015-P4/D

VFD-KDRB2L

20

15

30

CIE1-ED020-P4/D

VFD-KDRB1L

25

18.5

39

CIE1-ED025-P4/D

VFD-KDRD1L

30

22

45

CIE1-ED030-P4/D

VFD-KDRD2L

40

30

61

CIE1-ED040-P4/D

VFD-KDRC1L

For single phase sizing consult factory - 800.962.3787

13


VARIABLE FREQUENCY DRIVES

Enclosed P-Series VFD

7.5–40HP (200~230VAC), 7.5–400HP (380~480VAC), 3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

12 UL Type

UL 3R

Designed to Withstand Harsh Environments 3R or UL Type 12 packaging for outdoor and/or wash down applications Additional application-specific protective options - Lightning/Surge Arrestor - Line Reactors - Load Reactors - dV/dT Filter Rainproof UL Type 3R enclosure reduces thermal absorption with white, solar reflective finish and filtered cooling fans Standard enclosed VFD package is rated for 92° F outside temperature, non-direct sunlight Attain up to 110° F outside temperature, non-direct sunlight by de-rating VFD

Functionality A single VFD has the capability to control up to four additional motors reducing the need for additional controls

14

Sleep mode reduces energy consumption by stopping motors during periods of low demand Flexible sensor inputs accept 0-10VDC and 4-20mA analog signals VFD provides additional 12VDC and 24VDC power for sensors PID control and Pre-PID mode with time delay reduces water hammer and cavitation while providing precise system control Dual PID control for external PID control of a secondary system

www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

Ordering and Sizing Information Options Part Number

Description

VFD-RPL*

Run Pilot Light (Green Standard)

VFD-FLT*

Fault Pilot Light (Red Standard)

VFD-HOA

Hand/Off/Auto Switch

VFD-SPD

Door Mounted Speed Potentiometer

VFD-LTA

Lightning Arrestor

VFD-KPD

Door Mounted Keypad

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

* Select 24V or 120V based on package control voltage. For UL Type 1 select 24V. For UL Type 3R & 12 select 120V.

3-Phase, 200~230V Enclosed Packages Standard Duty (VT) 1Ø HP*

3Ø HP

FLA

UL Type 3R

UL Type 12

3% Line Reactor

Output Reactor

Output Filter

2

5

24

CIE3R-ED005-P2

CIE12-ED005-P2

VFD-KDRB22L

VFD-KDRD1P

VFD-V1K16A00

3

7.5

24

CIE3R-ED007-P2

CIE12-ED007-P2

VFD-KDRB23L

VFD-KDRD2P

VFD-V1K25A00

5

10

32

CIE3R-ED010-P2

CIE12-ED010-P2

VFD-KDRD25L

VFD-KDRD3P

VFD-V1K35A00

7.5

15

46

CIE3R-ED015-P2

CIE12-ED015-P2

VFD-KDRD24L

VFD-KDRC1P

VFD-V1K45A00

10

20

60

CIE3R-ED020-P2

CIE12-ED020-P2

VFD-KDRD26L

VFD-KDRF1P

VFD-V1K55A00

10

25

74

CIE3R-ED025-P2

CIE12-ED025-P2

VFD-KDRC22L

VFD-KDRF2P

VFD-V1K80A00

15

30

88

CIE3R-ED030-P2

CIE12-ED030-P2

VFD-KDRF24L

VFD-KDRF3P

VFD-V1K80A00

20

40

115

CIE3R-ED040-P2

CIE12-ED040-P2

VFD-KDRF25L

VFD-KDRH1P

VFD-V1K110A00

* Maximum HP of 3-phase motor in single phase power applications

3-Phase, 380~480V Enclosed Packages Standard Duty (VT) 1Ø HP*

3Ø HP

FLA

UL Type 3R

UL Type 12

3% Line Reactor

Output Reactor

Output Filter

2

5

12

CIE3R-ED005-P4

CIE12-ED005-P4

VFD-KDRA3L

VFD-KDRA3P

VFD-V1K8A00

3

7.5

12

CIE3R-ED007-P4

CIE12-ED007-P4

VFD-KDRA4L

VFD-KDRA4P

VFD-V1K12A00

5

10

16

CIE3R-ED010-P4

CIE12-ED010-P4

VFD-KDRA5L

VFD-KDRB1P

VFD-V1K18A00

7.5

15

24

CIE3R-ED015-P4

CIE12-ED015-P4

VFD-KDRB2L

VFD-KDRD1P

VFD-V1K21A00

10

20

30

CIE3R-ED020-P4

CIE12-ED020-P4

VFD-KDRB1L

VFD-KDRD2P

VFD-V1K27A00

10

25

39

CIE3R-ED025-P4

CIE12-ED025-P4

VFD-KDRD1L

VFD-KDRD3P

VFD-V1K35A00

15

30

45

CIE3R-ED030-P4

CIE12-ED030-P4

VFD-KDRD2L

VFD-KDRD4P

VFD-V1K45A00

20

40

61

CIE3R-ED040-P4

CIE12-ED040-P4

VFD-KDRC1L

VFD-KDRC1P

VFD-V1K55A00

20

50

75

CIE3R-ED050-P4

CIE12-ED050-P4

VFD-KDRF2L

VFD-KDRF1P

VFD-V1K80A00

20

60

91

CIE3R-ED060-P4

CIE12-ED060-P4

VFD-KDRF4L

VFD-KDRF2P

VFD-V1K80A00

20

75

110

CIE3R-ED075-P4

CIE12-ED075-P4

VFD-KDRF3L

VFD-KDRF3P

VFD-V1K110A00

20

100

152

CIE3R-ED0100-P4

CIE12-ED100-P4

VFD-KDRH3L

VFD-KDRH1P

VFD-V1K130A00

20

125

183

CIE3R-ED0125-P4

CIE12-ED125-P4

VFD-KDRH2L

VFD-KDRI1P

VFD-V1K160A00

* Maximum HP of 3-phase motor in single phase power applications

15


VARIABLE FREQUENCY DRIVES

Compact GS-Series VFD 0.5–5HP

200~230VAC, 380~480VAC, 3Ø Compact Design, Sensorless & VF Control

Sensorless vector control

Precise speed control and powerful high torque, up to 150% at 0.5 Hz Improves control with varying loads Auto tuning simplifies commissioning Sensorless mode also selectable

Space Vector Modulation for superior motor life Super clean sine wave for cool running motors and high efficiency Minimizes heat losses in for long motor life

Integrated PID Precise control to maintain flow-rate, pressure, temperature, etc. without any extra controller. Accepts -10V to 10V analog signals

With sensorless control the GS series makes motor control easy.

Operation algorithm Helps prevent nuisance tripping

Dynamic braking circuit Minimizes deceleration time on high inertia loads when used with braking resistors.

Built-in RS-485 communication Remote control and monitoring with other controllers (Modbus standard)

Ground-fault protection Superior equipment protection

Cooling fan control Quiet, low noise operation; easy to replace fan module

16

www.cerusind.com 1.800.962.3787

The easy to use 4-direction keypad makes settings a snap.


VARIABLE FREQUENCY DRIVES

Intuitive multi-direction keypad User friendly and easy use

Optional external keypad for remote control/monitoring Loader parameters can be downloaded effectively “cloning” inverters for fast set up in subsequent jobs

Specifications Output ratings

Input ratings

Voltage (V) Three phase, 200~230V or Three phase, 380~480V Frequency (Hz) 0~400Hz Voltage (V) Three phase, 200~230V (+10%, -15%) or Three phase, 380~480V (+10%, -15%) Frequency (Hz) 50~60Hz (±5%) Control method Sensorless Vector, V/F control (Space vector PWM) Frequency setting resolution Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.03Hz at 50Hz Frequency setting accuracy Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency V/F ratio Linear; Square; User V/F

Operation

Overload capacity 1 minute at 150%; 30 seconds at 200% (with inverse characteristic proportional to time) Torque boost Auto; Manual (0~15%) Assigned terminals FX (forward), RX (reverse), BX (inverter gate blocking), RST (reset), JOG (jog) Programmable input 8 digital inputs Analog output 0~10V linear Operator control 4 digit LED display/keypad, Terminals, ModBus communication Frequency setting Analog: 0~10V, 4~20mA, Digital: Keypad, Communication: ModBus Start signal Forward, Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal)

Input signal

Multi-step accel./decel. time 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational functions DC braking, Frequency limit, Frequency jump, function, Slip compensation, Reverse rotation prevention Emergency stop stops output from inverter Jog Jog operation Fault reset Resets fault signal when protective function is active

Output signal

Operational status

Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output (relay and open collector output)

Indicator Output frequency, Output current, Output voltage, DC voltage, rpm

Protective functions

Trip

Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, Overload, Speed command loss, Hardware fault, Communication error, etc.

Alarm Stall, Overload Ambient temperature -10°~ 50° C (14°~122° F) Storage temperature -20°~ 65° C (-4°~149.5° F) Operating environment

Humidity 90% Relative Humidity maximum (non-condensing) Altitude & Vibration 1000m max, 5.9m/sec2(0.6g) max. Application site No corrosive gas, flammable gas, oil mist or dust CI-000-GS2/GS4, CI-001-GS2/GS4 5.04” x 2.76” x 5.12” (Height is 6.90” w/ NEMA kit)

Dimensions (H x W x D)

CI-002-GS2/GS4 5.04” x 3.94” x 5.12” (Height is 6.90” w/ NEMA kit) CI-003-GS2/GS4, CI-005-GS2/GS4 5.04” x 5.51” x 6.10” (Height is 6.90” w/ NEMA kit) CI-000-GS2/GS4, CI-001-GS2/GS4 1.7 lbs

Weight (lbs)

CI-002-GS2/GS4 2.5 lbs CI-003-GS2/GS4, CI-005-GS2/GS4 4.1 lbs

17


VARIABLE FREQUENCY DRIVES GS Series Wiring

*For general reference only, not field wiring. Consult installation instructions.

3-Phase, 200~230V GS - Series VFD HP

kW

Capacity (kVA)

FLA

Part Number

NEMA 1 Kit

3% Line Reactor*

1/2

0.4

0.95

2.5

CI-000-GS2

CI-NEMA1-GS/A

KDRULA54LE01

1

0.75

1.9

5

CI-001-GS2

CI-NEMA1-GS/A

KDRULA25LE01

2

1.5

3

8

CI-002-GS2

CI-NEMA1-GS/B

KDRULA27LE01

3

2.2

4.5

12

CI-003-GS2

CI-NEMA1-GS/C

KDRULA28LE01

5

3.7

6.1

16

CI-005-GS2

CI-NEMA1-GS/C

KDRULB22LE01

* Line Reactors housed in separate UL Type 1 Enclosure

3-Phase, 380~480V GS - Series VFD HP

kW

Capacity (kVA)

FLA

Part Number

NEMA 1 Kit

3% Line Reactor*

1/2

0.4

0.95

1.25

CI-000-GS4

CI-NEMA1-GS/A

KDRULA6LE01

1

0.75

1.9

2.5

CI-001-GS4

CI-NEMA1-GS/A

KDRULA8LE01

2

1.5

3

4

CI-002-GS4

CI-NEMA1-GS/B

KDRULA1LE01

3

2.2

4.5

6

CI-003-GS4

CI-NEMA1-GS/C

KDRULA2LE01

5

3.7

6.1

8

CI-005-GS4

CI-NEMA1-GS/C

KDRULA3LE01

Options Description

18

* Line Reactors housed in separate UL Type 1 Enclosure Part Number

Remote Keypad Mounting Kit (2 Meter Cable)

CI-RKPK-EXT2M-GS

Remote Keypad Mounting Kit (3 Meter Cable)

CI-RKPK-EXT3M-GS

Remote Keypad Mounting Kit (5 Meter Cable)

CI-RKPK-EXT5M-GS

www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

Enclosed GS-Series VFD

0.5HP-5HP 200~230VAC, 380~480VAC, 3Ă˜ Compact Design, Senserless & VF Control

Representative photo only (acutal product may vary based on configuration selections)

Options

3-Phase, 200~230V GS-Series Enclosed VFD HP

kW Capacity (kVA) FLA

Base part #

3% Line Reactor*

1/2

0.4

0.95

Part Number

2.5

CIE12-ED000-GS2

VFD-KDRA54L

VFD-RPL*

Run Pilot Light (Green Standard)

1

0.75

1.9

5

CIE12-ED001-GS2

VFD-KDRA25L

2

VFD-FLT*

Fault Pilot Light (Red Standard)

1.5

3

8

CIE12-ED002-GS2

VFD-KDRA27L

VFD-OFF*

Off Pilot Light (Red Standard)

3

2.2

4.5

12

CIE12-ED003-GS2

VFD-KDRA28L

VFD-HOA

Hand/Off/Auto switch

5

3.7

6.1

16

CIE12-ED005-GS2

VFD-KDRA22L

VFD-SPD

Door Mounted Speed Potentiometer

VFD-LTA

Lightning Arrestor

VFD-KPD

Door Mounted Keypad

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

3-Phase, 380~480V GS-Series Enclosed VFD HP

kW Capacity (kVA) FLA

Base part #

3% Line Reactor*

1/2

0.4

0.95

1.25

CIE12-ED000-GS4

VFD-KDRA6L

1

0.75

1.9

2.5

CIE12-ED001-GS4

VFD-KDRA8L

2

1.5

3

4

CIE12-ED002-GS4

VFD-KDRA1L

3

2.2

4.5

6

CIE12-ED003-GS4

VFD-KDRA2L

5

3.7

6.1

8

CIE12-ED005-GS4

VFD-KDRA3L

Description

* Select 24V or 120V based on package control voltage. For UL Type 1 select 24V. For UL Type 3R & 12 select 120V.

19


VARIABLE FREQUENCY DRIVES

GS-Series Bypass

0.5–5HP 200~230VAC, 380~480VAC, 3Ø Space Vector Pulse Width Modulation

Standard HVAC bypass features

HAND/OFF/AUTO Fireman’s override/smoke purge ready 2 contactor with manual motor starter disconnect version UL 508C rating with all drive models for maximum motor protection

Wide range of design options

Door mounted controls, speed pot, HOA, & pilot lights Input or output drive reactors Electronic overload with full phase protection on bypass

Fully enclosed drives for any environment W e offer any enclosure type and NEMA ratings (Stainless, fiberglass, watertight, etc.) Dust tight type 12 enclosures include ducting and ventilation for maximum cooling

Applications Supply and return fans Performance contracting Building Automation

20

www.cerusind.com 1.800.962.3787

Interior Bypass Photo


VARIABLE FREQUENCY DRIVES

Options

Type 3R Rain Resistant

Type 1 Indoor

Part Number

Description

VFD-RPL*

Run Pilot Light (Green Standard)

VFD-BPL*

Bypass Pilot Light (Amber Standard)

VFD-FLT*

Fault Pilot Light (Red Standard)

VFD-OFF*

Off Pilot Light (Red Standard)

VFD-SPD

Door Mounted Speed Potentiometer

VFD-LTA

Lightning Arrestor

VFD-KPD

Door Mounted Keypad

VFD-KPD/4X

Door Mounted Keypad with Type 4X Cover

* Select 24V or 120V based on package control voltage. For UL Type 1 select 24V. For UL Type 3R & 12 select 120V.

3-Phase, 230V GS-Series VFD Bypass Bypass with Drive Isolation (3-Contactor) HP

FLA

1/2 1

2-Contactor Bypass Configuration

UL Type 1

UL Type 3R

UL Type 12

UL Type 1

UL Type 3R

UL Type 12

2.5

CIE1-BYP000-GS2/3

CIE3R-BYP000-GS2/3

CIE12-BYP000-GS2/3

CIE1-BYP000-GS2

CIE3R-BYP000-GS2

CIE12-BYP000-GS2

5

CIE1-BYP001-GS2/3

CIE3R-BYP001-GS2/3

CIE12-BYP001-GS2/3

CIE1-BYP001-GS2

CIE3R-BYP001-GS2

CIE12-BYP001-GS2

2

8

CIE1-BYP002-GS2/3

CIE3R-BYP002-GS2/3

CIE12-BYP002-GS2/3

CIE1-BYP002-GS2

CIE3R-BYP002-GS2

CIE12-BYP002-GS2

3

12

CIE1-BYP003-GS2/3

CIE3R-BYP003-GS2/3

CIE12-BYP003-GS2/3

CIE1-BYP003-GS2

CIE3R-BYP003-GS2

CIE12-BYP003-GS2

5

16

CIE1-BYP005-GS2/3

CIE3R-BYP005-GS2/3

CIE12-BYP005-GS2/3

CIE1-BYP005-GS2

CIE3R-BYP005-GS2

CIE12-BYP005-GS2

3-Phase, 460V GS-Series VFD Bypass Bypass with Drive Isolation (3-Contactor) HP

FLA

1/2

2-Contactor Bypass Configuration

UL Type 1

UL Type 3R

UL Type 12

UL Type 1

UL Type 3R

UL Type 12

1.25

CIE1-BYP000-GS4/3

CIE3R-BYP000-GS4/3

CIE12-BYP000-GS4/3

CIE1-BYP000-GS4

CIE3R-BYP000-GS4

CIE12-BYP000-GS4

1

2.5

CIE1-BYP001-GS4/3

CIE3R-BYP001-GS4/3

CIE12-BYP001-GS4/3

CIE1-BYP001-GS4

CIE3R-BYP001-GS4

CIE12-BYP001-GS4

2

4

CIE1-BYP002-GS4/3

CIE3R-BYP002-GS4/3

CIE12-BYP002-GS4/3

CIE1-BYP002-GS4

CIE3R-BYP002-GS4

CIE12-BYP002-GS4

3

6

CIE1-BYP003-GS4/3

CIE3R-BYP003-GS4/3

CIE12-BYP003-GS4/3

CIE1-BYP003-GS4

CIE3R-BYP003-GS4

CIE12-BYP003-GS4

5

8

CIE1-BYP005-GS4/3

CIE3R-BYP005-GS4/3

CIE12-BYP005-GS4/3

CIE1-BYP005-GS4

CIE3R-BYP005-GS4

CIE12-BYP005-GS4

230V Line Reactor Options

460V Line Reactor Options

HP

Part Number

HP

Part Number

1/2

VFD-KDRA54L

1/2

VFD-KDRA6L

1

VFD-KDRA25L

1

VFD-KDRA8L

2

VFD-KDRA27L

2

VFD-KDRA1L

3

VFD-KDRA28L

3

VFD-KDRA2L

5

VFD-KDRA22L

5

VFD-KDRA3L

21


COOLING TOWER PANEL

TOWER IQ Stand alone or Slave Operation Options Scalable to meet any application Cerus Energy Saving VFDs

All inclusive single point cooling tower control Integrates with an existing automation system or temperature control option for standalone application Scalable options to meet any application Adequately sized to add other options including spray pump, basin heater control, line reactors, and other critical features.

Smart Design

Cerus P-Series HVAC drive for optimum performance

Space-vector control for clean sinewave output for efficiency and enhanced motor life Automatic energy savings mode Dual PID controls. Primary for maintaining temperature, pressure, etc., additional for secondary PID control of external device. 32 character LCD for easy set up and parameter display. Standard kWh metering of energy usage to optimize control

Multiple PID set points Programmable and selectable for maintaining pressure or temperature during different seasons or operating conditions

Integrated HOA and 3-Contactor Bypass Standard Integrated HOA and status indications for simplified operation VFD isolating three contactor bypass with disconnect options standard

22

www.cerusind.com 1.800.962.3787

“Having the ability to retrofit existing installations with a stand-alone capable panel gives us immediate energy savings-regardless of the type of energy management system.”


VARIABLE FREQUENCY DRIVES

Single source control reduces components; increases reliability Wide range of options available. One connection point for power

Temperature control option provides complete stand alone operation.

Ideal for retrofit Start/stop sequencing for fans, dampers, and spray pumps Provides analog output to vary speed of drive Accepts direct input from RTD type sensor or thermocouple Adjustments for set-points and hysteresis

Additional Options 2-stage Temperature Control

Basin Heater Control Prevents freezing Contactor activated by external signal (i.e.thermostat). Provision for low water protection

86.5

Start/stop sequencing for fans, dampers, and spray pumps Provides analog output to vary speed of drive Accepts direct input from RTD type sensor or thermocouple Adjustments for set-points and hysteresis

Vibration cut-out

Line Reactors

Provision for vibration switch cut-out

For use in systems with unstable utility power, long leads from service transformer to VFD and/or when power source is greater than 10 times the kVA rating of the inverter Provides harmonic distortion filtering

Water Level Control Power Provides 120VAC @ 2A

Output Reactor/Filters Use when leads from drive to motor exceed 35’ at 480VAC or greater. Above 100’ use output filter Decreases level of voltage spikes to prevent motor insulation breakdown.

Spray Pump Starter Full voltage starter with overload relay HOA switch provided Status indication options

Panel Space Heater To prevent condensation and freezing

23


COOLING TOWER PANEL

Tower IQ Specifications Protective Functions Alarm

Alarm Stall, Overload, Temperature sensor fault

Trip

Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, Fuse open, Ground fault, External fault 1, 2, Option fault, Overload, Speed command loss, Hardware fault, Communication error, etc.

Input / Output Voltage

3 phase 200 – 230V (-15%,+10%) 50 -60Hz, 3 phase 480V (-15%,+10%) 50 -60Hz

Power Rating

7.5 HP to 400 HP

Efficiency

> 95%

Control Input

0-10 VDC, 4-20 mA, keypad, or digital input from communication card

Communication Options

BACnet, Modbus, LonWorks, N2, or RS485

Environmental

Package: UL Type 3R for outdoor or UL Type 12: Ambient temperature up to 110ºF; UL type indoor humidity up to 90%RH non-condensing. Drive: Ambient temperature up to 122ºF

Programmable I/O

8 digital inputs, 4 digital outputs, 2 analog outputs

Options

24

Spray Pump Starter

1 hp to 20 hp (output voltage matches panel main voltage)

Basin Heater

4 kW to 25 kW (output voltage matches panel main voltage)

De-Icer

Digital input for fan reverse

www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

Ordering and Sizing Information Options Part Number

Description

VFD-RPL*

Run Pilot Light (Green Standard)

VFD-BPL*

Bypass Pilot Light (Amber Standard)

VFD-FLT*

Fault Pilot Light (Red Standard)

VFD-OFF*

Off Pilot Light (Red Standard)

CTP-TC

Temperature Controller

CTP-60HTR

60W Panel Space Heater

CTP-250HTR

250W Panel Space Heater

* Select 24V or 120V based on package control voltage. For UL Type 1 select 24V. For UL Type 3R & 12 select 120V.

3-Phase, 200~230V Cooling Tower Control HP

FLA

UL Type 1

UL Type 3R

5

24

CTP1-BYP005-P2

CTP3R-BYP005-P2

VFD-KDRB22L

7.5

24

CTP1-BYP007-P2

CTP3R-BYP007-P2

VFD-KDRB23L

10

32

CTP1-BYP010-P2

CTP3R-BYP010-P2

VFD-KDRD25L

15

46

CTP1-BYP015-P2

CTP3R-BYP015-P2

VFD-KDRD24L

20

60

CTP1-BYP020-P2

CTP3R-BYP020-P2

VFD-KDRD26L

25

74

CTP1-BYP025-P2

CTP3R-BYP025-P2

VFD-KDRC22L

30

88

CTP1-BYP030-P2

CTP3R-BYP030-P2

VFD-KDRF24L

40

115

CTP1-BYP040-P2

CTP3R-BYP040-P2

VFD-KDRF25L

3% Line Reactor

3-Phase, 380~480V Cooling Tower Control HP

FLA

UL Type 1

UL Type 3R

3% Line Reactor

Output Reactor

Output Filter

5

12

CTP1-BYP005-P4

CTP3R-BYP005-P4

VFD-KDRA3L

VFD-KDRA3P

VFD-V1K8A00

7.5

12

CTP1-BYP007-P4

CTP3R-BYP007-P4

VFD-KDRA4L

VFD-KDRA4P

VFD-V1K12A00

10

16

CTP1-BYP010-P4

CTP3R-BYP010-P4

VFD-KDRA5L

VFD-KDRB1P

VFD-V1K18A00

15

24

CTP1-BYP015-P4

CTP3R-BYP015-P4

VFD-KDRB2L

VFD-KDRD1P

VFD-V1K21A00

20

30

CTP1-BYP020-P4

CTP3R-BYP020-P4

VFD-KDRB1L

VFD-KDRD2P

VFD-V1K27A00

25

39

CTP1-BYP025-P4

CTP3R-BYP025-P4

VFD-KDRD1L

VFD-KDRD3P

VFD-V1K35A00

30

45

CTP1-BYP030-P4

CTP3R-BYP030-P4

VFD-KDRD2L

VFD-KDRD4P

VFD-V1K45A00

40

61

CTP1-BYP040-P4

CTP3R-BYP040-P4

VFD-KDRC1L

VFD-KDRC1P

VFD-V1K55A00

50

75

CTP1-BYP050-P4

CTP3R-BYP050-P4

VFD-KDRF2L

VFD-KDRF1P

VFD-V1K80A00

60

91

CTP1-BYP060-P4

CTP3R-BYP060-P4

VFD-KDRF4L

VFD-KDRF2P

VFD-V1K80A00

75

110

CTP1-BYP075-P4

CTP3R-BYP075-P4

VFD-KDRF3L

VFD-KDRF3P

VFD-V1K110A00

100

152

CTP1-BYP0100-P4

CTP3R-BYP100-P4

VFD-KDRH3L

VFD-KDRH1P

VFD-V1K130A00

125

183

CTP1-BYP0125-P4

CTP3R-BYP125-P4

VFD-KDRH2L

VFD-KDRI1P

VFD-V1K160A00

Cooling Tower Options Basin Heater Contactor & Spray Pump Starter Basin Heater Contactor Spray Pump Starter kW 3 Phase HP Max Basin Heater Spray Pump 208V 230V 480V Amps 208V 230V 460V 3/4

3/4

2

2.5

CTP-9/HI-2.5

1/2

1/2

1

CTP-9/H-2.5

1

1.5

3

4.0

CTP-9/HI-4

3/4

3/4

2

CTP-9/H-4

2

2

4

6.0

CTP-9/HI-6

1

1.5

3

CTP-9/H-6

2.5

3

6

8.0

CTP-9/HI-8

2

2

5

CTP-9/H-8

3

3.5

8

10.0

CTP-18/HI-10

2

3

5

CTP-18/H-10

4

5

10

13.0

CTP-18/HI-13

3

3

7.5

CTP-18/H-13

6

6.5

14

17.0

CTP-18/HI-17

3

5

10

CTP-18/H-17

7.5

8.5

18

22.0

CTP-32/HI-22

5

7.5

15

CTP-32/H-22

9

10

21

26.0

CTP-32/HI-26

7.5

7.5

15

CTP-32/H-26

11

12

26

32.0

CTP-32/HI-32

7.5

10

20

CTP-32/H-32

25


VARIABLE FREQUENCY DRIVES

ENCLOSED DRIVES FOR ANY ENVIRONMENT Wide range of design options

Door mounted controls, speed pot, HOA, & pilot lights Input or output drive reactors Electronic overload with full phase protection on bypass

Cerus also offfers bypass assemblies for any environment

Fully enclosed drives for any environment W e offer any enclosure type and NEMA ratings (Stainless, fiberglass, watertight, etc.) Dust tight type 12 enclosures include ducting and ventilation for maximum cooling

We respond. And that’s got people talking www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

We offer engineered solutions for our starter and VFD products to suit your specific application requirement. Modifications include a full range of enclosure options capable of withstanding almost any environment, complex multi-motor control, or simply ensuring the controls follow a specific sequence of operations. We respond, often times with same day quotes depending on application complexity and job requirements.

Redundant Drive Configuration

With a Redundant Drive Package you have a backup

Easy set up thanks to 32 character LCD & simplified parameters Maximum Energy Savings with space vector control Versatile features for demanding applications, built in multi-motor control (for up to 4 additional motors) Torque boost and speed search features offer smooth motor starts


VARIABLE FREQUENCY DRIVES

P Series Dimensions *ALL MEASUREMENTS IN INCHES

P-Series Drive CI-007-P2 CI-007-P4

H x W x D, (A x B x C) 11.19”x 5.91” x6.17”

CI-010-P2 CI-010-P4 CI-015-P2

11.18” x 7.87” x 7.16”

CI-015-P4 CI-020-P2 C

CI-020-P4 CI-025-P2

15.16” x 9.84” x 7.94”

CI-025-P4 CI-030-P2 A B

CI-030-P4 CI-040-P2

18.11” x 11.97” x 9.22”

CI-040-P4

5.91”

6.17”

GS Series Dimensions *ALL MEASUREMENTS IN INCHES

GS-Series Drive

H x W x D, (A x B x C)

CI-000-GS2 CI-000-GS4

5.04”x2.76”x5.12”

CI-001-GS2 CI-001-GS4 CI-002-GS2 CI-002-GS4

5.04”x3.94”x5.12”

CI-003-GS2 CI-003-GS4 CI-005-GS2 CI-005-GS4

28

www.cerusind.com 1.800.962.3787

5.04”x5.51”x6.10”


VARIABLE FREQUENCY DRIVES

P-Series UL Type 1 Bypass Dimensions *ALL MEASUREMENTS IN INCHES 12.170”

UL Type 1 P-Drive Bypass

9.968” 9.967”

8.696”

8.000”

H x W x D (A x B x C)

CIE1-BYP001-P4 ~ CIE3R-BYP015-P4/3

40.13”x 8.00” x 8.12”

CIE1-BYP020-P4 ~ CIE1-BYP040-P4/3

50.12” x 9.98” x 8.67”

8.118”

CIE3R-BYP040-P2 50.185”

56.888”

40.125”

CIE3R-BYP040-P4 ~ CIE3R-BYP050-P4/3

56.9” x 12.17” x 9.97”

7.943”

8.256” 9.435”

GS Series UL Type 1 Bypass Dimensions *ALL MEASUREMENTS IN INCHES UL Type 1 GS-Drive Bypass 7.590

5.854

CIE1-BYP000-GS2 ~ CIE1-BYP005-GS2 CIE1-BYP000-GS4 ~ CIE1-BYP005-GS4

H x W x D (A x B x C)

32.00”x7.59”x5.84”

32.000

29 6.826


VARIABLE FREQUENCY DRIVES

P-Series UL Type 3R Bypass Dimensions *ALL MEASUREMENTS IN INCHES

UL Type 3R P-Drive Bypass CIE3R-BYP001-P2 ~ CIE3R-BYP010-P2/3 CIE3R-BYP001-P4 ~ CIE3R-BYP015-P4/3 CIE3R-BYP015-P2 ~ CIE3R-BYP020-P2/3 CIE3R-BYP040-P4 ~ CIE3R-BYP040-P4/3

H x W x D (A x B x C) 35” x 24” x 12”

41” x 24” x 12”

CIE3R-BYP040-P2 CIE3R-BYP040-P4 ~ CIE3R-BYP050-P4/3 CIE3R-BYP075-P4 ~ CIE3R-BYP075-P4/3

47” x 24” x 14”

56” x 36” x 16”

CIE3R-BYP040-P2/3

A

CIE3R-BYP060-P4 ~ CIE3R-BYP060-P4/3

42” x 30” x 16”

CIE3R-BYP100-P4 ~ CIE3R-BYP125-P4/3

67” x 36” x 16”

GS-Series UL Type 3R Bypass Dimensions *ALL MEASUREMENTS IN INCHES UL Type 3R GS-Drive Bypass CIE3R-BYP000-GS2 ~ CIE3R-BYP005-GS2 CIE3R-BYP000-GS4 ~ CIE3R-BYP005-GS4

A

30

www.cerusind.com 1.800.962.3787

H x W x D (A x B x C)

29” x 14” x 12”


VARIABLE FREQUENCY DRIVES

P-Series UL Type 12 Enclosed Dimensions *ALL MEASUREMENTS IN INCHES

12 P-Series Enclosed Drive

B

CIE12-ED007-P2/P4 CIE12-ED010-P2/P4 CIE12-ED015-P2/P4 CIE12-ED020-P2/P4

H x W x D, (A x B x C) 24”x20”x8” 30”x24”x12”

CIE12-ED025-P2/P4 CIE12-ED030-P2/P4

A

CIE12-ED040-P4

36”x24”x12’

CIE12-ED040-P2 CIE12-ED050-P4 CIE12-ED060-P4

36”x30”x16”

CIE12-ED075-P4 C

CIE12-ED100-P4 CIE12-ED125-P4 CIE12-ED150-P4 CIE12-ED200-P4 CIE12-ED250-P4

D

CIE12-ED350-P4 CIE12-ED400-P4

42”x30”x16” 60”x36”x20” 60”x48”x18” 72”x36”x24”

E

GS-Series UL Type 12 Enclosed Dimensions *ALL MEASUREMENTS IN INCHES B

12 GS-Series Enclosed Drive

H x W x D, (A x B x C)

ALL GS NEMA 12 Enclosures

16”x14”x8”

A

C

D

E

31


VARIABLE FREQUENCY DRIVES

P-Series UL Type 3R Enclosed Dimensions *ALL MEASUREMENTS IN INCHES 3R P Series Enclosed Drive

H x W x D, (A x B x C)

CIE3R-ED007-P2/P4

28”x24”x12”

CIE3R-ED010-P2

30”x20”x10”

CIE3R-ED010-P4 CIE3R-ED015-P2 CIE3R-ED015-P4 CIE3R-ED020-P2/P4 CIE3R-ED025-P2/P4 CIE3R-ED030-P2/P4

29”x24”x12” 35”x24”x12” 42”x24”x12’

CIE3R-ED040-P2

47”x24”x12”

CIE3R-ED040-P4

42”x24”x12’

CIE3R-ED050-P4 CIE3R-ED060-P4

47”x24”x14”

CIE3R-ED075-P4 CIE3R-ED100-P4 CIE3R-ED125-P4

A

CIE3R-ED150-P4 CIE3R-ED200-P4

56”x36”x16” 60”x46”x18”

GS-Series UL Type 3R Enclosed Dimensions *ALL MEASUREMENTS IN INCHES

3R GS Series Enclosed Drive H x W x D, (A x B x C) ALL GS NEMA 3R Enclosures

A

32

www.cerusind.com 1.800.962.3787

16”x12”x8”


VARIABLE FREQUENCY DRIVES

Cooling Tower Panel Dimensions *ALL MEASUREMENTS IN INCHES Cooling Tower Panel H x W x D, (A x B x C) Panel Dimensions

Mounting Pattern

35” x 24” x 12”

35.94”x13.00”

41” x 24” x 12”

41.94”x13.00”

47” x 24” x 14”

47.94”x13.00”

56” x 36” x 16”

55.94”x27.00”

67” x 36” x 16”

67.94”x27.00”

A

33


VARIABLE FREQUENCY DRIVES

Optimized Line Reactors 3 Phase, 600V Class UL & CE Marked Open Chassis & UL Type 1

Features

Optimized Line Reactors (200~230V)

Reduces input line distortion Eliminates transient and overvoltage nuisance tripping Provides excellent harmonic mitigation without adding capacitance Improve true power factor Helps to prevent VFD component damage

3%

5%

HP

Open Chassis

UL Type 1 Enclosed

Open Chassis

UL Type 1 Enclosed

1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40

KDRA54L KDRA53L KDRA25L KDRA26L KDRA27L KDRA28L KDRB22L KDRB23L KDRD25L KDRD24L KDRD26L KDRC22L KDRF24L KDRF25L

KDRULA54LE01 KDRULA53LE01 KDRULA25LE01 KDRULA26LE01 KDRULA27LE01 KDRULA28LE01 KDRULB22LE01 KDRULB23LE01 KDRULD25LE01 KDRULD24LE01 KDRULD26LE01 KDRULC22LE01 KDRULF24LE01 KDRULF25LE01

KDRA54H KDRA53H KDRA25H KDRA27H KDRA26H KDRA28H KDRB25H KDRB26H KDRD21H KDRD22H KDRC22H KDRF28H KDRF25H KDRF26H

KDRULA54HE01 KDRULA53HE01 KDRULA25HE01 KDRULA27HE01 KDRULA26HE01 KDRULA28HE01 KDRULB25HE01 KDRULB26HE01 KDRULD21HE01 KDRULD22HE01 KDRULC22HE01 KDRULF28HE01 KDRULF25HE01 KDRULF26HE01

Optimized Line Reactors (380~480V) 3%

Industrial Surge Arrestors Description

Part Number

3-Wire 1Ø 0~250V

LA-302

4-wire 3Ø 0~600V

LA-603

Specifications

34

Maximum current: 100kA Maximum energy: 3000J Unlimited number of surges Response times to clamp: - 1 mA test: 5 ns - 10kA: 10 ns - 50kA: 25 ns

www.cerusind.com 1.800.962.3787

5%

HP

Open Chassis

UL Type 1 Enclosed

Open Chassis

UL Type 1 Enclosed

1/2 3/4 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400

KDRA6L KDRA7L KDRA8L KDRA9L KDRA1L KDRA2L KDRA3L KDRA4L KDRA5L KDRB2L KDRB1L KDRD1L KDRD2L KDRC1L KDRF2L KDRF4L KDRF3L KDRH3L KDRH2L KDRH1L KDRG3L KDRG1L KDRG2L KDRJ2L KDRJ1L

KDRULA6LE01 KDRULA7LE01 KDRULA8LE01 KDRULA9LE01 KDRULA1LE01 KDRULA2LE01 KDRULA3LE01 KDRULA4LE01 KDRULA5LE01 KDRULB2LE01 KDRULB1LE01 KDRULD1LE01 KDRULD2LE01 KDRULC1LE01 KDRULF2LE01 KDRULF4LE01 KDRULF3LE01 KDRULH3LE01 KDRULH2LE01 KDRULH1LE01 KDRULG3LE01 KDRULG1LE01 KDRULG2LE01 KDRULJ2LE01 KDRULJ1LE01

KDRA6H KDRA7H KDRA8H KDRA9H KDRA1H KDRA2H KDRA3H KDRA4H KDRA5H KDRB2H KDRC3H KDRC1H KDRE2H KDRF4H KDRF1H KDRF2H KDRH2H KDRH1H KDRG3H KDRG1H KDRJ1H KDRL1H KDRL2H KDRL3H KDRL4H

KDRULA6HE01 KDRULA7HE01 KDRULA8HE01 KDRULA9HE01 KDRULA1HE01 KDRULA2HE01 KDRULA3HE01 KDRULA4HE01 KDRULA5HE01 KDRULB2HE01 KDRULC3HE01 KDRULC1HE01 KDRULE2HE01 KDRULF4HE01 KDRULF1HE01 KDRULF2HE01 KDRULH2HE01 KDRULH1HE01 KDRULG3HE01 KDRULG1HE01 KDRULJ1HE01 KDRULL1HE01 KDRULL2HE01 KDRULL3HE01 KDRULL4HE01


VARIABLE FREQUENCY DRIVES

Drive Output Reactors & Filters 3 Phase, 600V Class UL & CE Marked UL Type 1 & 3R Available

Output Reactors

dV/dT Output Filters

Protection for motor leads between 50 - 100 ft Protects VFD output by dampening peak voltage overshoot Extends motor life by reducing heat and audible noise Helps prevent VFD instantaneous overcurrent trips

Optimized Output Reactors Horsepower 240V

480V

3/4 1 2 3 5 7.5 10 15 20 25 30 40 -

2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400

Protection for motor leads exceeding 100 ft Ensures smooth VFD sinusoidal output to motor Extends motor life by reducing heat, audible noise and insulation breakdown Reduces “reflective wave” effect by limiting peak voltage and rise time Helps prevent VFD instantaneous overcurrent trips

Optimized dV/dT Output Filter

Open Chassis

UL Type 1 Enclosed

KDRA1P KDRA2P KDRA3P KDRA4P KDRB1P KDRD1P KDRD2P KDRD3P KDRD4P KDRC1P KDRF1P KDRF2P KDRF3P KDRH1P KDRI1P KDRI2P KDRG1P KDRJ1P KDRJ2P KDRL1P KDRL2P

KDRULA1PE01 KDRULA2PE01 KDRULA3PE01 KDRULA4PE01 KDRULB1PE01 KDRULD1PE01 KDRULD2PE01 KDRULD3PE01 KDRULD4PE01 KDRULC1PE01 KDRULF1PE01 KDRULF2PE01 KDRULF3PE01 KDRULH1PE01 KDRULI1PE01 KDRULI2PE01 KDRULG1PE01 KDRULJ1PE01 KDRULJ2PE01 KDRULL1PE01 KDRULL2PE01

Horsepower 240V

480V

1/2 3/4 1-1.5 2 3 5 7.5 10 15 20 25-30 40 -

3/4 1-1.5 2 3 5 7.5 10 10 15 15 20 25 30 40 50 - 60 75 100 125 150 200 250 300 350 400

Open Chassis

UL Type 1 Enclosed

V1K2A00 V1K3A00 V1K4A00 V1K6A00 V1K8A00 V1K12A00 V1K16A00 V1K18A00 V1K21A00 V1K25A00 V1K27A00 V1K35A00 V1K45A00 V1K55A00 V1K80A00 V1K110A00 V1K130A00 V1K160A00 V1K200A00 V1K250A00 V1K305A00 V1K362A00 V1K420A00 V1K480A00

V1K2A01 V1K3A01 V1K4A01 V1K6A01 V1K8A01 V1K12A01 V1K16A01 V1K18A01 V1K21A01 V1K25A01 V1K27A01 V1K35A01 V1K45A01 V1K55A01 V1K80A01 V1K110A01 V1K130A01 V1K160A01 V1K200A01 V1K250A01 V1K305A01 V1K362A01 V1K420A01 V1K480A01

35


VARIABLE FREQUENCY DRIVES

Gage Pressure Sensors 0~500 PSIG Models Stainless Steel Construction 36” Wire Leads, 1/4”-18 NPT

Accurate, Reliable & Versatile Cerus pressure sensors are ideal for industrial and commercial applications where measurement and performance are critical. Additionally, these micro-machined sensors are compact in size, constructed of rugged materials designed to meet the highest standards of chemical compatibility.

Engineered for Superior Accuracy & Performance

±0.5% overall full scale at room temperature ±1% overall full scale over -40°C to 105°C for 75 PSI to 200 PSI Includes repeatability, hysteresis and linearity Custom ASIC provides signal conditioning for calibration and temperature compensation Optional electrical connectors available (Packard, Deutsch, Mini DIN, M12, Integral Harness)

Solid Construction Laser-welded stainless steel design for optimal media isolation Withstands up to three times full scale burst pressure Reverse voltage protected Gage Pressure Sensors

36

0-5VDC Output

4-20mA Output

Pressure Range

Part Number

Part Number

0-15 PSIG

PG-15SB

PG-15SC

0-25 PSIG

PG-25SB

PG-25SC

0-50 PSIG

PG-50SB

PG-50SC

0-75 PSIG

PG-75SB

PG-75SC

0-100 PSIG

PG-100SB

PG-100SC

0-250 PSIG

PG-250SB

PG-250SC

0-300 PSIG

PG-300SB

PG-300SC

0-500 PSIG

PG-500SB

PG-500SC

www.cerusind.com 1.800.962.3787


VARIABLE FREQUENCY DRIVES

Differential Pressure Transducers 0~2” & 0~25” WC Models Dual Output Signals (4-20mA & 0-5/10VDC) Open Frame & NEMA 4 Enclosure Options

Intrinsic Flow Measurement Technology for High Accuracy

Intrinsic flow measurement results in optimal performance No gravity effect allows mounting in any position LCD display for easy setup and commissioning Switch-selectable pressure ranges Applications include static pressure measurement, variable air volume system control and monitoring filter status

Differential Pressure Transducers - 0”~2” WC Pressure Range 0~1"

Specifications 12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output)

Power Supply Output Type

0~2”

Dual, 4-20mA & 0-5/10VDC (3-wire) 0-1” (Selectable 0.1, 0.5, 1.0) uni or bi-directional

Output Scaling

Pressure Range

32° to 122°F (0-50°C)

0~10"

Media compatibility

Dry, oil-free air, N2

Sensor Type

Digital CMOS intrinsic flow differential pressure

0~25"

Performance Position Effects

Part Number

Open Frame

PDP30-001

NEMA 4

PDP31-001

NEMA 4 w/ Probe

PDP32-001

Open Frame

PDP30-002

NEMA 4

PDP31-002

NEMA 4 w/ Probe

PDP32-002

Differential Pressure Transducers - 0”~25” WC

0-2” (Selectable 0.5, 1”, 2”) uni or bi-directional

Calibrated Temperature Range

Enclosure Type

Enclosure Type

Part Number

NEMA 4

PDP31-010

NEMA 4 w/ Probe

PDP32-010

NEMA 4

PDP31-025

NEMA 4 w/ Probe

PDP32-025

None - position insensitive Zero drift

Zero point Accuracy 0.5 Pa Span Accuracy 3% of reading

NEMA 4 enclosed Cerus Pressure Transducer shown with probe.

Zero point repeatability 0.1 Pa Span repeatability 0.5% of reading Temp offset None (less than resolution) Temp span shift < 0.5% of reading per 10°C

Selectable Ranges, Outputs and Stable Dry Media Operation

Zero drift technology ensures precision measurement LCD display for easy setup and commissioning Auto zero pushbutton input and auto zero control contact for system accuracy Applications include duct pressure monitoring and air-flow stations

Specifications Power Supply Output Type Output Scaling Calibrated Temperature Range Media Sensor Type Performance Accuracy (Linearity, hysteresis, temperature) Auto-zero input

12-30VDC/24VAC, 30mA maximum (13VDC min for 10V full scale output) Dual, 4-20mA & 0-5/10VDC (3-wire) 0-10” (Selectable 2.5, 5, 10"WC) 0-25” (Selectable 10, 15, 25"WC) 50° to 140°F (10-60°C) Dry, oil-free air, N2 Integrated, micro machined silicon piezoresistive

2.5% full scale Pushbutton and contact closure input provided

37


VARIABLE FREQUENCY DRIVES

DRIVE INSTALLATION A,B,C’s

A drive is a sensitive piece of power electronics that when installed properly will provide you with years of trouble-free operation. While our drives have many built-in protective features, if the installation or application is incorrect, failures due to improper protection or installation will not be covered under warranty. To avoid this ugly situation we have developed the Drive Installation A, B, C’s. Know these basic A,B,C’s with every drive you purchase.

Ambient Temperature: The maximum ambient temperature for a drive installation is either 40°C (104°F) or 50°C (122°F). Here are some recommendations to help keep your drive “cool”: 1. Derating for Temperature: If the drive is installed in an environment where the ambient temperature will be near or exceed 40°C or 104°F and the drive is rated for 40°C or the drive is in an enclosure and the ambient temperature will be over 90° F you will need to derate the drive to meet the temperature requirements. For our P, S and H series drive you can derate the drive 20% to increase the temperature rating by 20%. For example a 50 Hp P Series Drive which is normally rated for 40°C, when derated by 20% by use with a 40 Hp motor, can operate up to 50°C or 122°F. 2. Reduce the heat load on the Drive: Mount the drive or drive panel away from direct sunlight. 3. Exhaust and Intake Clearance: Make sure the drive is mounted in a place where the intake and exhaust air is free from obstructions and the intake air is not near another heat source such as transformers orheating elements. Never install one drive such that the exhaust from one blows into the intake of another. 4. Mount the drive in a Separate Enclosure: A simple step that can save a lot of headaches is to mount the drive separately from other electrical equipment. Just a few extra devices in an enclosure can add significant heat that can push the internal ambient temperature of the cabinet beyond what is acceptable for the drive.

Bonding Nothing is more important for a drive than proper grounding. Improper grounding can cause everything from unexplained shutdowns to erratic operation. Where we see the most problems with grounding are in remote locations (like an irrigation pump) or isolated installations such as cranes or roof tops for HVAC. There are three critical things to remember about grounding your drive: 1. Size of the ground cable. The ground bonding cable must be the proper size to meet the impedance requirements as specified in our manual. A good practice is to use the same size as your input power input. 2. Dedicated, direct cable. The grounding cable should be dedicated and as short as possible from the bonding point. Longer cable runs will require larger cable to meet the impedance requirements. This is where following the recommendations above will serve you well. Under no circumstances should you use a mechanical connection such as conduit or electrical cabinets for your ground source. 3. Bonding to the source input. Ideally the grounding and source input are electrically connected such as when there is an isolation transformer with a neutral to ground bonding point.

Clean Power, Correct Sizing & Clean Air Correct Sizing: How your drive performs is dependent upon sizing the drive properly for the application. Your load is either constant torque or variable torque. Most Cerus drives are dual rated - the variable torque rating is always higher capacity than the constant torque rating. Here are some examples of variable and constant torque applications:

38

Constant Variable Conveyer Belt Fan Most Mixers Pump Grinder Some Mixers Lathe 1.800.962.3787 www.cerusind.com

High Inertia Oil Pump Jack Centrifuge Any Flywheel Crane and Hoist


VARIABLE FREQUENCY DRIVES

The A,B,C’s: • Ambient Temperature- of the installation • Bonding- make sure your grounding is correct • Clean Power and Air flow- for proper cooling • Correct Sizing- for the application When sizing a drive you also must consider the inertia of the load. High inertia loads are hard to accelerate and decelerate. This resistance to speed change can cause the drive to trip out on DC overvoltage, as the inertia from the load reverses into the drive and causes the DC bus voltage to rise. When this happens the drive will trip on an overvoltage fault. Resetting the fault and putting the drive back in operation in this situation will void your warranty if done repetitively. In all such cases a dynamic braking unit with a dynamic breaking resistor should be used. Dynamic braking units are standard on many of our small drives and are optional on all of our larger drives. Correct Settings: To protect your drive and to insure proper operation, follow our quick start guide which includes settings for most applications. Clean Air: A drive that becomes coated with dust or debris cannot cool itself properly and will lead to premature failure of the drive. Make sure the drive has clean, dry air for cooling. If it is installed in an enclosure make sure to replace or properly clean the air filters once a month to make sure the drive runs at peak performance. Clean Power: The drive will need to be protected from input power problems and load related power issues (mainly due to long cable runs or bad utility power). There are unique issues regarding both input power and output power protection:

1. Input Power Surge Protection or Lightning Arrestor: Semiconductors on the front end of any drive have a very limited ability to withstand high voltage surges or spikes. While there is built in protection in the drive, it is preferable to have surge protection installed at the drive input source (the closer to the utility input the better). This way, any type of surge or spike is eliminated before it gets to the drive. See our drive accessories page for our recommended solutions. If your drive is going into a commercial building, often this type of protection has already been installed for other sensitive equipment such as computer servers or UPS equipment. 2. Input Line Reactor: As a rule of thumb, an input line reactor may be required when the drive is installed directly to the utility source and the utility KVA rating is 10 times higher than that of the drive rating. In more specific terms if the source impedance is lower than 2.5%, a line reactor is required. When installed, an input line reactor adds impedance between the source and the drive. This has two benefits- first it helps to filter the drive harmonics from the rest of the installation and in turn protects the drive from line noise and transients. Secondly, line reactor’s additional impedance reduces the voltage stress on the input power circuits caused by the drive operation. 3. Output Power Protection: In some cases you may need an output line reactor to protect the drive and motor from output related voltage spikes. Some applications that require this type of protection include:

• Downwell pump motors • Large motors above 100 hp • Motors with leads longer than 35’ or SO cords • Older motors or motors that are wound without “inverter duty” insulation. If you have a motor load that meets any of these conditions, please contact our customer service personnel for recommendations. There are no universal rules that can be applied with respect to output line reactors, despite what you may have heard. In any application, whether a line reactor is required is simply a function of physics with the motor winding, the switching voltage and power cabling. Every switch on or off from the output of the inverter transistor will cause a voltage overshoot that may be enough to exceed the insulation breakdown of the motor windings or exceed the transistor breakdown voltage of the inverter or both. Our staff is knowledgeable with most applications and can provide you with the correct recommendation for your specific situation. 39


22995 NW Evergreen Pkwy Hillsboro, OR 97124

PRSRT STD US POSTAGE PAID BEAVERTON, OR PERMIT NO. 50

In addition to our top quality drives, we offer a wide variety of starters for constant volume applications.