STANDARD FEATURES • P-Series VFD with Space Vector Pulse Width Modulation • High interruption, lockable MMS Disconnect • Door mounted HOA and Bypass switches • Smoke purge and run enable • Available in 2 or 3 contactor configurations • Standard control power transformer (CPT) • UL 508C rating with all drive models for maximum motor protection • Integrated ModBus RTU (additional comms options available)
Enclosure Options • UL Type 1 (NEMA 1) slimline enclosure • UL Type 3R (NEMA 3R) outdoor-rated enclosure with integrated ducting, ventilation and thermostat for maximum cooling
Optional Features • Door mounted VFD keypad, speed control and pilot lights • Line (Input) or Load (Output) drive reactors to mitigate harmonics • Input circuit breaker (MCCB style) • Communication card options for RS485, N2, BACnet or LonWorks • Electronic overload with full phase protection on bypass • Panel space heaters available for ambient temperatures below 32°F
Date
Project Name
Rep Firm Contractor Engineering Firm
Submitted Equipment Schedule
Selected Options CI-R4-COM RS485 Communication Card
* Carefully review your submitted selections based on the desired package configuration. An example part number is displayed below to confirm your selections.
CI N2-COM N2 Communication Card CI-BN-COM BACnet communication Card CI-LW-COM LonWorks Communication Card VFD-KDR### 3% Input Line Reactor VFD-RPL Run Pilot Light (Green Standard) VFD-BPL Bypass Pilot Light (Amber Standard) VFD-FLT Fault Pilot Light (Red Standard) VFD-OFF Off Pilot Light (Red Standard) VFD-EOL Electronic Overload VFD-LTA Lightning Arrestor VFD-KPD Door Mounted Keypad VFD-KPD/4X Keypad with Type 4X Cover VFD-SPD Door Mounted Speed Potentiometer
QTY
TAG
BYPASS CONFIGURATION
PART NUMBER
HP
VOLTAGE
ENCLOSURE RATING
Date Rep Firm Contractor Engineering Firm
Project Name
Date Rep Firm Contractor Engineering Firm
P-Series VFD Specifications
Project Name
Date Rep Firm Contractor Engineering Firm
Main Power Circuits
Project Name
Date Rep Firm Contractor Engineering Firm
Control Power Circuits
Project Name
Date Rep Firm Contractor Engineering Firm
P-Series VFD Wiring
Project Name
Date Rep Firm Contractor Engineering Firm
Sensor Wiring - 7.5HP-40HP
Project Name
Date Rep Firm Contractor Engineering Firm
Bypass Contactor Specifications
Project Name
Date
Project Name
Rep Firm Contractor Engineering Firm
Motor Circuit Protector Disconnect Specifications
Date
Project Name
Rep Firm Contractor Engineering Firm
MCP Short Circuit Thermal Limits Thermal limit in KA in the magnetic operating zone (Ue=415V) CMS-32H/HI
Thermal limit in KA in the magnetic operating zone (Ue=415V) CMS-63H/HI
Date Rep Firm Contractor Engineering Firm
Physical Dimensions - UL Type 1
Project Name
Date
Project Name
Rep Firm Contractor Engineering Firm
Physical Dimensions - UL Type 3R