Sheet Name
G 1.0
General Information
Z 1.0 – 1.6
Zoning Analysis
C 1.0 -1.4
Site Analysis
S 1.0 – 1.1
Structural System
A 1.0
First Floor Plan
A 1.1
Second Floor Plan
A 1.2
Additional Plans
A 1.3
Perspectives, Site Plan
A 1.4
Perspective
M 1.0
Mechanical Systems
P 1.0 – 1.1
Plumbing Systems
FP 1.0
Fire Protection Systems
AP 1.0
Acceptance Panel
New residential facility located on the Grand River in Grand Rapids, Michigan. Situated in the blooming Arena South district adjacent to downtown this residence creates a new community incorporated into the new expanded riverfront development. This mixed income housing complex strives to reconnect the people of Grand Rapids with their river.
Design Criteria: Occupancy Classification, per IBC 2009 Use and Occupancy Classification: Primary Use Groups: B- Business R-2- Residential A-2- Assembly M- Mercantile
Means of Egress:
DECISIONS:
Occupancy Load: B- Business = 100 gsf = 21,318 / 100 = 213.2 R-2- Residential = 200 gsf = 82,440 / 200 = 412.2 M- Mercantile = 30gsf = 45,450 / 30 = 1515
Incidental Use Groups: Storage rooms over 100 square square feet Automated Parking Garage with One Hour fire seperstion and automatic fire extinguishing system With Sprinkler System: Stairways = 0.3 in General Building Height and Areas: Other Egress Components = 0.2 in B- Business 21,318 R-2- Residential 82,440 B- 213.2 x 0.2in = 42.64 inches A-2- Assembly 3,553 M- 1515 x 0.2in = 303 inches M- Mercantile 45,450 Exit access tavel distance with sprinkler system: 250 feet Allowable Area: Unlimited, per table 503 IBC
Type of Construction Type 1A Fire Protection (per IBC 2009) Fire Supression System Yes, automated sprin kler throughout Smoke Detection Yes Occupancy Seperation 1 hour, or automated sprinkler system in incidental use occupancies 3 hourhorizontal seperation between S-2 and R-2
PRIMARY BUILDING CODES: IBC-INTERNATIONAL BUILDING CODE 2009 NFPA- NATIONAL FIRE PROTECTION ASSOCIATION; nfpa-101 “life safety code” 2009 IECC- INTERNATIONAL ENERGY CONSERVATION CODE NEC- NATIONAL ELECTRIC CODE IPC- ILLINOIS PLUMBING CODE IMC- INTERNATIONAL MECHANICAL CODE ASME- ELEVATOR ASME FEDERAL AGANCIES: ATBCB- ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD EPS- ENVIRONMENTAL PROTECTION AGENCY OSHA- OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION; OCCUPATIONAL SAFETY AND HEALTH ACT NATIONAL ORGANIZATIONS: ACI- AMERICAN CONCRETE INSTITURE AISC- AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI- AMERICAN IRON AND STEEL INSTITUTE ANSI- AMERICAN NATIONAL STANDARDS INSTITUTE ASCE/SEI- AMERICAN SOCIETY OF CIVIL ENGINEERS/ STRUCTURAL ENGINEERING INSTITUTE ASHRE- AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIT CONDITIONING ENGINEERS; ENERGY CONSERVATION IN NEW BUILDINGS ASME- AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASPE- AMERICAN SOCIETY OF PLUMBING ENGINEERS ASTM- AMERICAN SOCIETY OF TESTING MATERIALS; STANDARDS AND CERTIFICAIONS NCMA- NATIONAL FIRE PROTECTION ASSOCIATION PCA- PORTLAND CONCRETE ASSOCIATION CODE ABBREVATIONS: ACI- AMERICAN CONCRETE INSTITUTE ADAAG- AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES PCI- PRECAST/PRESTRESSED CONCRETE INSTITUTE UL- UNDERWRITERS LABORATORIES
I. Grayson
G 1.0
Allowable Height: Unlimited, per Downtown Height Overlay District
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
2.Characteristics. The valued characteristics of the built environment of a Traditional Neighborhood include: a. A pattern of small blocks, alleys and a connected street grid system; b. Smaller building footprints on small sites with variable lot sizes; c. Human-scaled buildings with high quality exterior materials; d. Front façades oriented parallel to the street; e. Pedestrian and transit orientation, with widespread provision of on-street parking and off-street surface parking areas that are located to the rear of the lot; f. Integrated residential and nonresidential land uses located in the same building or in proximity to one another without extensive buffering; g. Well-defined building entries and windows constituting at least fifty (50) percent of the front façade; and h. Other building elements and architectural patterns. City Center (CC):
Apartments will reside above storefronts, within a centralized neighborhood Characteristics:small blocks, alleys, small bld. footprints, human scale, front facade to street, Pedestrian and transit orientation, to reduce need for on-site parking Well defined building entrances recessed Preserve and reuse older blds. Employment opportunities for downtown residents Balconies sixteen (16) foot head clearance, five (5) feet over public sidewalk
City Center acknowledges downtown Grand Rapids as the business and cultural heart of the metropolitan region. A dense development pattern focused on the close proximity of services, a diversity of uses and dynamic building styles characterize this Zone District. The compatibility of such intense development with surrounding neighborhoods is emphasized through the use of a transitional Zone District.
Most of site conforms to eighty-five (85) foot height overlay. Except portion between Grandville Ave and river has no height limit, but must contend with riverfront development overlay.
TN-CC, Traditional Neighborhood - City Center Zone District. The intent of this District is to maintain and enhance the vitality of downtown, reinforce its intense development pattern, provide services in close proximity to one another, allow diverse uses, and maintain the presence of older, often historic, buildings. The compact development pattern of downtown establishes a pedestrian-oriented and transit-friendly environment. The City Center Zone District stresses pedestrian circulation, urban and civic design, protection of natural features, and encourages the reuse of existing buildings. Specific objectives are intended to:
Waste recepticals need to be full inclosed, and at the rear of the building. In areas with multipal fronts, prefer recepticals to be incorperated into building footprint.
1. Accommodate and promote commercial, residential, entertainment, educational, cultural, artistic, health care-related and governmental uses within the City Center Zone District; 2. Improve mobility options downtown, and to reduce the need for on-site parking by encouraging alternative means of transportation, including use of mass transit, bicycle use and other traffic demand management options; 3. Preserve and reuse older buildings, as well as establish standards for the construction of new ones; 4. Expand the employment base and residential population of downtown; 5. Improve walkability and pedestrian interest; 6. Reinforce the unique physical character of downtown, focusing on the design context; 7. Express the community’s special commitment to the visual quality of downtown by establishing minimum criteria for building design compatibility while promoting amenities necessary to attract business, residents and visitors.
Site Map
DECISIONS:
Projections into the Public Right-of-Way.
I. Grayson
Z 1.0
Grand Rapids, Michigan Zip Code: 49503 Latitude: 42° 57’ 44” N, Longitude: 85° 40’ 19” W
Traditional Neighborhoods (TN): 1.Background. Developed prior to society’s dependence on the automobile, these neighborhoods were designed to provide residents with a variety of commercial, institutional and residential options within a short walking distance. Residents find housing options such as single-family homes and apartments above storefronts, as well as commercial and institutional uses integrated into a central neighborhood design. Diversity in building size and use enhances the vitality of these neighborhoods.
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
1. Balconies. A balcony with a minimum ground clearance of sixteen (16) feet above finished grade may extend five (5) feet over a public sidewalk, provided an encroachment permit is obtained from the City Engineer. 2. Awnings. An awning with a minimum ground clearance of eight (8) feet may extend over a public right-of-way, provided and encroachment permit is obtained from the City Engineer. 3. Canopies. Canopy support posts shall not be permitted in a public right-of-way. See also Section 5.2.24. (Ord. No. 2009-09, § 4-6, 03-24-2009), (Ord. No. 2009-48, § 4, 09-15-2009), (Ord. No. 2011-54,§ 2-6, 11-29-2011)
D.Size. The waste receptacle base shall be at least nine (9) feet by six (6) feet in area, constructed on six (6) inches of reinforced concrete pavement. The base shall extend six (6) feet beyond the waste receptacle pad or gate to support the front axle of a refuse vehicle. The enclosure shall have a minimum height of six (6) feet or one (1) foot above the height of the waste receptacle, whichever is greater. The enclosure shall have at least three (3) feet of space on each side of the waste receptacle. E. Placement. 1. Preferred Placement. When possible, the back side of the waste receptacle enclosure should be placed against the building. In this circumstance the wall may act as one side of the enclosure.
DECISIONS: Stormwater Credit: no more than twenty five (25) percent can come from prevous surfaces. Retention of one hundred (100) percent of stormwater on site could allow for a reduction of requird greenspace. Use durable building materials, aknowledge transparency requirements.
2. Front yard. Waste receptacles and enclosures shall not be placed in the front yard. A. Measurement. When specified in feet, building height shall be measured as the vertical distance from the average grade adjacent to the structure to the highest point of a flat roof; to the deck line of a mansard roof; and to the average height between the eave and ridge of the highest roof section for a gable, hip or gambrel roof. See Section 5.16.02.G. for definition of average grade. B.Exceptions The height and area requirements of all Zone Districts shall be subject to the following exceptions: parapet walls not exceeding four (4) feet in height, chimneys, cooling towers, elevator bulkheads, fire towers, gas tanks, utility penthouses, stacks, stage towers or scenery lofts, monuments, cupolas, domes and spires and necessary mechanical appurtenances. 2. Dual Height Requirements. The TN-CC Zone District assigns two (2) different building height boundaries within the District through the use of the OD–DT Downtown Height Overlay District, Section 5.8.02. The height of buildings in the TNCC Zone District shall comply with the following: a. Base District. Structures in the base Zone District are not subject to a height limitation. b. Height Overlay District. Structures in the Height Overlay District shall not exceed eighty five (85) feet in height, except that a project may qualify for increased height based upon the bonus height allowance(s) provided in Section 5.8.02.C. Commercial Waste Receptacles and Enclosures. A.Applicability. The requirements of this Section shall apply to all non-residential properties, residential multi-family buildings of six (6) or more units, and to group living facilities with thirteen (13) or more adult residents.
3. Rear and side yards. Waste receptacles and enclosures shall be located in the rear or side yard not closer than three (3) feet from the rear or side lot line, unless otherwise approved by the Planning Director. 4. Residential use adjacent. Waste receptacles and enclosures shall be placed a minimum of twenty (20) feet from an adjacent residential use. 5. Landscape Buffer. A waste receptacle enclosure shall not be placed within a required landscape buffer area, as described in Section 5.11.11. F. Access. Waste receptacles shall be easily accessed by refuse vehicles without the potential to damage automobiles parked in designated parking spaces or interfering with the normal movement of vehicles on or off the site.
A clearly defined and usable building entrance required for every sixty (60) feet of builfing frontage on primary street. A horizontal Expression Line should distinguish the pedestrian environment at the base of a building. Downtown Height Overlay eighty five (85) foot height restriction in TN-CC Zone No height restrictions in OD-DH District
Minimum Required Greenspace. Stormwater Credit. No more than twenty five (25) percent of pervious surfaces, such as grass pavers, uncovered decks, brick pavers with a sand base, pervious concrete and asphalt, may be applied toward the greenspace requirements of this Section. Exception. A reduction of not more than fifty (50) percent of the required greenspace listed in Table 5.6.07.A. is permitted for development projects that satisfy at least one of the following criteria: a. The submission of a stormwater mitigation plan that retains one hundred (100) percent of all stormwater on site, as approved by the City’s Environmental Protection Services Department (EPSD); and submittal of a LEED checklist and proof of registration that demonstrates the intent to apply for LEED building certification, or other generally recognized sustainable building certification.
B.Enclosure. All outdoor waste, recycling and compostreceptacles, including grease barrels, shall be enclosed on three (3) sides and screened. The fourthside of the enclosure shall consist of a gate, made ofwood, vinyl, or other high quality material, asdetermined by the Planning Director. If the wastereceptacle is a dumpster it shall have an enclosing lid or cover.
b. Payment in lieu to the Grand Valley Regional Biosolids Authority Purchase of Development Rights (PDR) program. The payment shall be the percentage of the Market Value of the total amount of property equivalent to that percent of the property being used for the greenspace reduction. For example, a given property with a Market Value of $200,000 and a 10% greenspace requirement may reduce greenspace by 5% with a payment of $10,000 to the Regional Biosolids Authority (5% of $200,000).
C.Materials. The enclosure shall be constructed of brick or decorative textured block wall to recognize the permanence of the structure, reduce maintenance requirements and lessen the opportunity for graffiti or vandalism. The enclosure shall be consistent with the building materials of the main building. Steel or concrete bollards shall be installed to assist in the positioning of dumpsters and to protect the enclosure.
Building Element Requirements. Building Height Dual Height Requirements. The TN-CC Zone District assigns two (2) different building height boundaries within the District through the use of the OD–DT Downtown Height Overlay District, Section 5.8.02. The height of buildings in the TNCC Zone District shall comply with the following:
I. Grayson
Z 1.1
Building Height.
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
Materials. 1. Durable building materials, simple configurations and solid craftsmanship are required. Fifty (50) percent of walls visible from public streets, exclusive of wall areas devoted to meeting transparency requirements shall be constructed of: brick, glass; fiber cement siding, metal (beams, lintels, trim elements and ornamentation only); wood lap, stucco, splitfaced block, or stone. EIFS, and vinyl or aluminum siding should only be used for accents. Metal siding may be used as a primary building material if allowed by the Planning Commission with Special Land Use approval. 2. Administrative Departure. The Planning Director may approve materials of equivalent or better quality, as determined appropriate for the building, site, and area. Entrances. 1. Identifiable Entrance. A clearly identifiable and usable building entrance is required for every sixty (60) feet of a building’s frontage on a primary street. 2. Recessed Doorways. Where the building entrance is located on or within five (5) feet of a lot line, doorways shall be recessed into the face of the building to provide a sense of entrance and to add variety to the streetscape. a. The entrance recess shall not be less than the width of the door(s) when opened outward b. The entrance recess may not exceed the entrance width; and c. The entrance may not exceed two (2) stories in height. Expression Line (EL) 1. A horizontal line on the façade known as the Expression Line (EL) shall distinguish the base of the building from the remainder to enhance the pedestrian environment. The EL shall be created by a change in material, a change in design, or by a continuous setback, recess, or projection above or below the Expression Line. Such elements as cornices, belt courses, corbelling, molding, stringcourses, ornamentation, and changes in material or color or other sculpturing of the base, are appropriate design elements for ELs. 2. If applicable, the height of the Expression Line shall be related to the prevailing scale of development in the area. A change of scale may require a transitional design element between existing and proposed features. Transparency. 1.Purpose. The first floors of all buildings shall be designed to encourage and complement pedestrian-scale activity and crime prevention techniques. It is intended that this be accomplished principally by the use of windows and doors arranged so that active uses within the building are visible from or accessible to the street, and parking areas are visible to occupants of the building.
B. Height Requirements. The TN-CC Zone District assigns two (2) different building height boundaries. Structures within the B Height Area of the OD-DH Zone District are not subject to a height limitation. Structures within the A Height Area of the OD-DH shall not exceed eighty five (85) feet in height, except as provided in Section 5.8.02.C. below. C. Bonus Height Allowance. Height bonuses are offered as incentives to encourage uses and amenities that implement the Master Plan. A bonus height allowance permits a project to extend beyond building height limitations as permitted in Table 5.6.08.A., Building Elements Table, where the project includes certain desirable features. Buildings shall qualify for a bonus height allowance based upon the gross floor area of the development devoted to such features and the criteria established in this Section. Total combined bonus height allowances shall not exceed ninety (90) feet or seven (7) stories, whichever is less. Grand River Overlay District (OD-GR). A.Purpose. As Grand Rapids’ most significant natural asset, the Grand River plays an important role in enhancing the quality of life of its residents. The Grand River Overlay District is intended to capitalize on the value of the Grand River as an essential economic, recreational and environmental resource by encouraging land use changes from industrial to open space and mixed-use development. The Grand River Overlay District seeks to remedy past development practices and land use patterns that limited the extent to which people could view, access and enjoy the riverfront by providing opportunities for viewsheds, easements and recreational opportunities. It is intended that: 1. Visibility of the Grand River shall be expanded and enhanced by requiring building setbacks that will provide for greater sight distances. 2. Existing river walk segments shall be extended along the entire length of the Grand River to allow for a continuous connection alongside the River for recreational and environmental quality purposes through donation, acquisition and easements. 3. Wildlife corridors along the River’s edges shall be supported through a continuous network
DECISIONS: Grand River Overlay: Encourage land use changes from industrial to open space and mixed use development. Larger building setbacks, for greater sight distances Creation of people-oriented destination along river Activity on both street and river side of property Parking areas and parking structures shall be seperated from the river by intervening buildings, unless retail provided on ground floor Land between building and river will be designed as open space for pedestrian use Mechanical equipment , noise, smoke, and oders are not to be located on the river side of a building
B A
Downtown Height Overlay District (OD–DH). A.Purpose. The purpose of the Downtown Height Overlay District (OD–DH) is to allow building heights to exceed eighty five (85) feet where mixed-use redevelopment is provided within the TN-CC Zone District, also known as Downtown. A diversity of uses is essential for the creation of a vibrant, successful and economically sustainable central business district. Residential, retail and greenspace uses create a pedestrian-friendly environment that enhances property values, contributes to quality of life and sustains the Downtown as a regional asset. High-rise buildings shall comply with all necessary building code requirements to ensure proper fire protection.
I. Grayson
Downtown Overlay District
Z 1.2
OVERLAY DISTRICTS
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
of greenspaces. Water quality shall be improved with the introduction of less-intense, mixed land uses that are setback from the River’s edge as opposed to present, directly abutting industrial uses and paved surfaces. 4. A variety of people-oriented destinations shall be created along the river walk to provide visual interest, activity and vibrancy. Mixed-use development and highdensity residential construction are essential components for encouraging pedestrian activity and public safety. B.Applicability. The requirements of this Overlay District shall apply to any lot or parcel shown on the Grand River Overlay map, from the ordinary high water mark, floodwall or dock line, whichever is applicable as determined by the Planning Director, on each side of and paralleling the Grand River. This Overlay District shall not be construed to be separate from the base Zone District. In all cases, applicants for building permits in the Grand River Overlay District shall meet all requirements of the base Zone District, and shall also conform to the additional provisions, requirements and restrictions of the ODGR. Where there is conflict between other provisions of this Chapter and those specifically applied in the OD-GR, the latter shall control. C.Uses. All uses in the TN-Transitional City Center (TN-TCC) Zone District are allowed in the OD-GR District. D.Site Layout and Building Placement Requirements. 1. Where a property directly abuts the Grand River, buildings shall be sited to encourage pedestrian activity on both the street side and river side of the property. 2. All development in the OD-GR District shall comply with the requirements in Table 5.8.03.D. unless otherwise expressly stated. Where specified, these requirements supersede the site layout and building placement requirements of the base Zone District. E. Building Elements. 1. All development in the OD-GR District shall comply with the requirements in Table 5.8.03.E. unless otherwise expressly stated. Where specified, these requirements super-
sede the building element requirements of the Zone District. Where not specified, the requirements of the underlying zone district shall prevail. 2. A general similarity in building heights is encouraged along the river corridor to provide a sense of visual continuity. Building heights should be configured to provide views to the Grand River and other significant landmarks while allowing an appropriate density. 3. Parking areas and parking structures shall be separated from the river by intervening buildings, except: a. Where retail space is provided on the ground floor of the parking structure, and at least fifty (50) percent of its façade is used as display windows; or b. Where a mural or other public art approved by the Planning Commission is provided on the parking structure, or in a landscaped area along the river. c. Where (a) or (b) apply, the parking area or structure shall have a minimum required front setback of thirty (30) feet from the Grand River. 4. Land between the building and the river shall be landscaped, and designed as an urban open space for pedestrian use. 5. Pedestrian walkways that connect to the river’s edge shall be provided betweenbuildings, parking areas or structures, and other built features such as outdoor plazas and courtyards. 6. Service areas and mechanical equipment shall be visually unobtrusive and shall be integrated with the design of the site and building. a. Utility boxes shall be positioned so they cannot be seen from the river or primary street by locating them on the sides of buildings and away from pedestrian and vehicular routes. b. Air intake and exhaust systems, or other mechanical equipment that generates noise, smoke or odors shall not be located on the river side of buildings. (Ord. No. 2009-48, § 18, 09-15-2009), (Ord. No. 2010-20, § 12, 05-11-2010)
DECISIONS: Minimum greenspace applies to off-street parking, stacking and loading areas. Street surfacing: asphalt, concrete, brick, stone, pavers, or equivalent No parking lot to exceed the required parking spaces by more than twenty (20) percent. Approval required for extra parking, in this instance all stormwater runoff created must be retained on site.
Section 5.10.03. General Standards for Off-Street Parking, Stacking and Loading Areas. B. Location. All off-street parking areas shall be provided on the same lot as the use it serves. However, parking may be allowed on another lot where there are practical difficulties in the location of the parking area or if public safety or public convenience is better served by another location. Required parking shall be provided no further than three-hundred (300) feet from the nearest point of the building to the nearest point of the parking facility along public rights-of-way. Parking may be owned, leased or shared by the owner of the building with another building owner upon providing evidence of agreements or easements to the Planning Director. C.No On-Street Parking. Public right-of-way shall not be used to satisfy the minimum number of required off-street parking spaces, except as allowed in Section 5.10.05.B. D.Minimum Size. Each off-street parking space shall have an area of not less than one hundred forty (140) square feet, exclusive of access drives or aisles, and conform with the Dimensional Standards in Table 5.10.04.D. E.Curbs and Vehicle Stops. All off-street parking lots, access drives and aisles, and other vehicle maneuvering areas shall provide curbs or similar devices to prevent vehicles from overhanging on or into public right-of-way, sidewalks, walkways, adjacent property, or landscape areas.
J. Outdoor Lighting. New or redeveloped off-street parking, stacking and loading areas shall comply with the standards of Section 5.2.25. regarding Outdoor Lighting.
Grand River Overlay District
K. Landscaping and Streetscape Elements. 1. All parking areas shall be landscaped in accordance with Article 11. Required landscape areas shall be protected from vehicular encroachment and damage by curbs or pinned wheel stops. 2. Streetscape elements (e.g. benches, trash receptacles, light fixtures, bollards, fountains,
I. Grayson
Z 1.3
F.Defined Areas. Off-street parking areas of three (3) or more spaces and off-street loading areas shall include painted lines, curbs, vehicle stops or other similar identifiers to delineate parking and loading areas.
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
M. Minimum Greenspace. Off-street parking, stacking and loading areas are subject to minimum greenspace calculations as established within each Zone District. N. Surfacing. 1. All off-street parking, stacking, loading areas and drive approaches from the alley or street shall be surfaced with asphalt, concrete, brick, stone, pavers, or an equivalent material in accordance with 1993 City of Grand Rapids Standard Construction Specifications as amended. Surfaces such as pervious asphalt, pervious concrete or turf blocks are permitted; subject to Chapter 32 of the City Code and other City policies pertaining to stormwater management. O. Access. 1. All off-street parking, stacking and loading areas shall be arranged for convenient access and safety of pedestrians, bicyclists, and vehicles. Where a parking area abuts an alley, access to the parking area shall be obtained from the alley. Where a parking area does not abut an alley, and abuts two (2) or more streets, access to the parking area shall be from the street with the lower traffic volumes. An Administrative Departure may be granted if, due to the particular situation of the parcel, this requirement cannot be satisfied. P. Large Parking Lots (200 or more parking spaces). 1. Large off-street parking lots shall be designed to simulate a grid pattern through the placement of landscape islands, buildings, and drive aisles. 2. Large off-street parking lots shall include primary drive aisles that are designed to appear as an extension of the public street network, extending the full length of the main building façades. 3. Utility placement on sites with large parking lots shall be configured to allow for future new buildings on the site. T. Parking Demand Study. The Planning Director may require the submittal of an independent parking demand study that analyzes parking demand based on the recommendations of the Institute of Traffic Engineers (ITE), and includes relevant data collected from uses or combinations of uses that are the same or comparable to the proposed use in terms of density, scale, bulk, area, type of activity and location. (Ord. No. 2009-09, § 49, 03-24-2009), (Ord. No. 2009-48, § 31, 09-15-2009), (Ord. No. 2010-20, § 31, 05-11-2010) Section 5.10.04. Parking Requirements. B. Maximum Parking. To minimize excessive areas of pavement no parking lot shall exceed the required number of parking spaces by more than twenty (20) percent, except as approved by the Planning Director. In granting additional spaces, the Planning Director shall determine that the parking is needed, based on documented evidence of actual use and demand provided by the applicant. All stormwater runoff created as a result of the additional parking area shall be completely retained onsite for any rainfall that is less than or equal to the 25 year, 24 hour rainfall. Stormwater facilities shall be reviewed and approved by the City’s Environmental Services Department. D. Traditional Neighborhood City Center (TN-CC) Zone District Parking Requirements. 1. Off-street parking shall not be required for any building or structure constructed prior to January 1, 1998 within the TN-CC Zone District, nor for new buildings or cumulative additions to existing buildings with a gross floor area of ten thousand (10,000) square feet or less. 2. Off-street parking spaces in the TN-CC Zone District shall be provided for all new buildings or structures and for additions to existing buildings or structures with a gross floor area of more than ten thousand (10,000) square feet. The number of spaces required for all uses shall be one (1) space for each one thousand (1,000) square feet of Gross Floor Area for all non-residential buildings and hotels, and one (1) space per dwelling unit for all dwellings. 3. If an existing building in the TN-CC Zone District is changed to a new permitted use,
no increase in the number of required parking spaces is required for the building. 4. Vehicular access from surface or structured parking areas to or from Monroe Center Street is prohibited. F. Mixed-Use Parking Coefficient. Where the Planning Director determines that a mix of land uses could reduce the number of required parking spaces, Table 5.10.05.F. below shall be used. To calculate mixed-use parking requirements, the required parking for each use shall be totaled, and then divided by the appropriate mixed use coefficient: Section 5.10.06. Loading/Unloading Spaces. A. Purpose. In all Zone Districts, every building or part thereof which is to be occupied by one or more uses that require the receipt or distribution of materials or merchandise by vehicles shall provide and maintain off-street loading spaces as required by this Section.
DECISIONS: Loading/unloading docks should not be directly visiable from the street Loading/unloading cannot interfere with normal vehical and pedestrian traffic. Turning raddi must be show on site plan for largest intended truck.
B. Location. 1. Loading/unloading areas and docks shall be prohibited in the front yard or on any building side facing and directly visible from a street. 2. Loading/unloading operations shall not interfere with the normal movement of vehicular and pedestrian traffic in public rights-of-way, off-street parking areas or internal drives and sidewalks. 3. No loading space that is adjacent to a residential Zone District shall be located closer than thirty (30) feet to the Zone District line unless it is contained within a completely enclosed building, or enclosed on all sides by a wall or solid fence not less than six (6) feet in height. 4. The vehicular path and turning radii to the loading area must be shown on the site plan to verify truck maneuverability for the largest truck intended to serve the use. C. All required loading/unloading spaces shall be at least twelve (12) feet in width, thirty (30) feet in length, and have fourteen (14) feet of clearance. Each additional required loading space shall be at least ten (10) feet in width, forty five (45) feet in length, and have fourteen (14) feet of clearance. D. The minimum number of loading spaces shall be provided in accordance with Table 5.10.06.D. Loading Space Requirements below. Section 5.11.02. Applicability. A. Type of Projects. The requirements of this Article shall apply to all development projects that require a Land Use and Development Services (LUDS) permit, are subject to Chapter 32 of the City Code, or for any change to the use of a lot, building or structure per the provisions for nonconformities in Article 3 of this Chapter. C. No Action Before LUDS Permit. Where a LUDS permit is required, no removal of vegetation, ground cover or trees shall be undertaken prior to the issuance of a LUDS permit. Section 5.11.03. Landscape Plan Submittal Requirements. A landscape plan shall be submitted as part of plan approval. The final plan shall include, but not necessarily be limited to, the following. A. Contour Lines. Existing and proposed site contours on the project site and one hundred (100) feet beyond the site lot lines, at intervals not to exceed two (2) feet. B. Cross Section. Typical cross section, including slope, height and width, of berms and the type of ground cover to be placed on them. C. Existing Vegetation. Location, size, general type and quality of existing vegetation, including specimen trees. D. Protection. Methods and details for protecting existing vegetation during construction. E. Removal or Preservation. Identification of existing trees and other landscape elements to be removed or preserved.
I. Grayson
Z 1.4
bicycle racks, etc.) shall be compatible with the architectural features of buildings or structures in the Neighborhood Classification to help establish a unifying theme for the Zone District. Where an adopted Streetscape Plan exists, the plan shall be followed.
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
F. Plant Materials. Location, size, spacing, and species of proposed plant material, including plant lists showing the required and proposed quantities. G. Minimum Compliance. 1. Calculations verifying the minimum landscaping required for the site under this Article. Required trees or plant materials shall not be double counted. 2. Calculations verifying the minimum percentage of required landscape area(s). H. Irrigation. Description of irrigation methods for landscape areas. I. Wetlands. Delineation of wetlands, streams and other water bodies. J. Walls. Location, height and type of any fences or walls measuring thirty (30) inches or higher. K. Maintenance. Description of landscape maintenance program, including statement that all diseased, damaged or dead materials shall be replaced in accordance with the requirements of this Article. Maintenance of rain gardens shall comply with the policies of the City’s EPSD. Section 5.11.05. General Standards for Landscaping. A. Required Vegetation. All areas not covered by buildings, parking areas, driveways, walkways, pedestrian plazas or other pedestrian-oriented impervious surfaces or water surfaces shall be planted with living vegetation, including canopy trees, shrubbery and ground covers. B. Topsoil. Topsoil shall be installed with a minimum depth of four (4) inches for lawn areas, and eight (8) to twelve (12) inches within planting beds. C. Stabilization. All landscape planting areas shall be stabilized and maintained with seed, sod, ground covers, mulches or other approved materials to prevent soil erosion and allow rainwater infiltration. D. Planting Beds. Bark used as mulch shall be maintained at a minimum depth of two (2) inches. Planting beds shall be edged with plastic, metal, brick or stone in residential Zone Districts and metal edging in all other Zone Districts.
tion thereof. Landscape islands that contain a tree must be a minimum of one hundred sixty (160) square feet and a minimum of nine (9) feet wide. All other landscape areas shall not be less than twenty (20) square feet. 3. Landscape area may be aggregated. Landscaped corners may count toward the required number of islands. 4. If a pedestrian pathway is included as a component of a landscape island, the island shall be a minimum of eleven (11) feet wide. The pathway shall be five (5) feet wide, with three (3) feet wide landscape areas. C. Minimum Landscape Buffer Standards. 1. The following minimum standards shall apply to Zone Districts in the three Neighborhood Classifications shown in Table 5.11.11.C.1. 3. A minimum of forty (40) percent of the required trees shall be deciduous canopy trees, except columnar trees or other vegetation recommended by the City forester may be used in areas with existing overhead utilities; 4. At least fifty (50) percent of the required trees shall be of an evergreen variety; and 5. At least seventy five (75) percent of all shrubs shall be evergreen or a dense variety of deciduous bush that provides year-round screening. Section 5.11.14. Alternative Energy. A. Wind Energy Systems. For the purposes of this Section, an “On Site Use Wind Energy System” is intended to primarily serve the needs of the consumer, but may be connected to the utility grid under certain circumstances. “Utility Grid Wind Energy Systems” are intended to serve the needs of the community and are connected to the utility grid. Applicable screening and buffering requirements shall apply. Wind energy systems are permitted as an accessory use in all districts, subject to the requirements of Table 5.11.14.A.
DECISIONS: One canopy tree required per twenty five (25) parking spaces. Landscape islands with trees should be one hundred and sixty (160) square feet. Other landscape areas no smaller than twenty (20) square feet. Minimum of forty (40) percent of required trees should be deciduous canopy. Minimum of fifty (50) percent of required trees shall be of an evergreen variety. Minimum of seventy five (75) percent of all shrubs shall provide dence year round screening.
B. Solar Energy. 1. Accessory Use. Solar energy systems are permitted as an accessory use in all Zone Districts. In Residential Zone Districts, solar energy systems may be installed on the roof of a primary or accessory structure, subject to the requirements of this Chapter. 2. Placement. The placement of any solar collection system shall be affixed so as not to adversely affect the pleasure and enjoyment of nearby residential uses.
Section 5.11.06. Plant Material Requirements. A. Plant Materials. All plant material shall be hardy to the Grand Rapids area, be free of disease and insects and conform to the American Standard for Nursery Stock of the American Nurserymen.
Section 5.11.07. Parking and Loading Area Landscape Requirements. E. Interior Landscape Standards. Landscape islands and shade trees shall be located throughout the parking lot to relieve and shade expanses of parking, and contribute to the orderly circulation of motor vehicle and pedestrian traffic. 1. Any parking lot designed for a capacity of twenty five (25) vehicles or more shall provide interior landscape areas at regular intervals. The required landscape area shall be a minimum of twenty (20) square feet per parking space. 2. There shall be a minimum of one (1) canopy tree per twenty five (25) parking spaces or frac-
Setbacks
I. Grayson
Z 1.5
F. Unaccredited Trees. Table 5.11.06.F. Unaccredited Trees lists species that are permitted but shall not be credited toward required landscaping because of their brittleness, susceptibility to disease and insects, overly expansive root structure, excessive litter, and or other undesirable characteristics. The planting of these species is not encouraged. Prohibited Species. Planting the species as listed in Table 5.11.06.G. is prohibited in the City due to their invasive nature. Other species that shall be avoided may be viewed at http://www.invasivespeciesinfo. gov/ (Ord. No. 2009-48, § 34, 09-15-2009)
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS:
A
Fourteen (14) foot setback Area available for most types of development
B
Flood Plain: 100 year, at 600 FASL 500 yeat, at 630 FASL
References: grcity.us/design-and-development-services/ Planning-Department/Pages/Zoning-Ordiance-Text-and-Maps.aspx fema.gov
Flood Zone
grcity.us, Crime in Grand Rapids, 2012, PDF
Police Station Fire Station
Hospital Municipalities
I. Grayson
Z 1.6
A- 100 year flood, 600 FASL B- 500 year flood, 630 FASL
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS:
1
Unpleasent sound and sight lines to south of site near highway 131 Views to downtown skyline to the north
3
College campus views to west across river, as well as hobo camp at rivers edge. Steam power plant in middle of site. Large Arena space bring in people in large groups and egresses them the same. Ionia street, entertainment districe, good place for resturant and night life development. Close proximity to transit terminal to the south. Future green corridor along river, with public space development
2
End of Site, View From Downtown Hotel
2 South End of Site on Grandville, Looking towards Downtown at Sunset
3 North East Corner of Site, Looking Down Ionia Street into the Entertainment District
I. Grayson
C 1.0
1 Grand River and Parking Lot at West
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: Reference passive solar design. Large hill to east may prolong sunrise Clear views to the south, except near the raised portion of Highway 131 Long shadows produced in evening and morning around stadium.
I. Grayson
Shadow Studies December 21, 3pm
Shadow Studies December 21, 8am
Shadow Studies June 21, 7pm
C 1.1
Shadow Studies June 21, 5am
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS:
534 Cooling Degree Days 6973 Heating Degree Days 75 inches of Snow 39 inches of Snow Annual Average Annual Average
96 Partly Cloudy Days
64 Days of Sun
Weather Data
Real estate along skyway should cater to conferences and arena event crowds. Skywalk is not heavily used by public, and acts a visual barrior between the south side of the site and downtown. Development around arena may consider tapping into existing steam lines. Consider snow loads when designing roofs
Heating will requre the most energy use Cooling requirements are relatively low, all efforts should be made to perform cooling passively.
Skywalk Route
I. Grayson
Underground Steam Plant Access
C 1.2
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
345°
Wind Frequency (Hrs)
0.6%
0.3%
0.8%
0.7%
1.4%
1.7%
1.3%
1.7%
0.5% 30 km/h 0.4%
57 51
40 km/h 0.1%
0.3%
0.1%
285°
64+ 30°
315°
300°
15°
330°
Location: Grand Rapids, USA (42.9°, -85.5°) Date: 1st December - 28th February Time: 00:00 - 24:00 © Weather Tool
hrs
44
45°
38
0.1%
0.4% 0.8% 0.5% 20 km/h
0.2% 0.3% 2.0% 1.3% 1.4% 1.0% 1.1% 0.1% 0.1% 1.4% 2.5% 1.3% 0.3% 0.1% 0.0% 0.1% 0.2% 0.8% 0.0% 0.5% 2.4% 1.2% 2.9% 0.1% 0.0% 1.1% 1.0% 0.9% 1.3% 1.6% 0.0% 1.1% 0.9%0.8%0.6% 1.2% 1.9% 0.2% 0.6% 0.3% 255° 1.6% 0.9% 2.0% 1.3% 0.2% 0.1% 1.9% 1.3% 0.4% 0.0% 1.1% 1.3% 2.6% 0.5% 0.2% 1.5% 0.8% 0.3% 3.0% 240° 1.3% 0.3% 0.1% 1.3% 0.8% 0.2% 0.1% 0.4% 0.1% 225° 135°
75°
[Duration shown as percentages]
Prevailing Winds
345°
© Weather Tool
NORTH
50 km/h
120°
hrs 30°
59 52
40 km/h
0.2%
0.3%
0.8% 1.1% 0.4%
46
45°
0.0%
39
0.5%
0.8% 0.7% 0.5% 20 km/h 1.1% 1.7% 1.1%
19 13
0.3%
<6
0.4%
0.0% 1.4% 0.1% 1.3% 1.1%1.1%1.2% 1.5% 1.3% 0.5% 10 km/h0.9% 1.4% 1.7% 0.9% 0.2% 0.4% 0.2% 1.6% 1.6% 0.5% 1.2% 1.5% 0.0% 0.2% 0.1% 0.0% 0.1% 0.2% 1.1% 2.3% 2.5% 2.9% 1.2% 0.3% 0.3% 2.8% 3.0% 1.6% 0.9% 0.1% WEST 0.4% 0.5% 1.3% 0.4% 0.6% 1.8% 2.2% 1.8% 0.4% 0.5% 0.6% 2.4% 0.4% 1.3% 1.4% 1.7% 0.2% 2.4% 1.9%2.5%2.0% 1.3% 0.9% 0.2% 255° 1.6% 0.6% 2.1% 2.0% 0.1% 3.2% 1.1% 0.0% 1.0% 0.4% 1.8% 0.4% 0.0% 1.2% 0.3% 0.1% 1.0% 240° 0.8% 0.0% 0.4% 0.2% 0.0%
75°
EAST
105°
120°
135°
345°
Wind Frequency (Hrs)
[Duration shown as percentages]
© Weather Tool
SOUTH
165°
35
0.3%
0.3%
28
60°
0.0% 300°
0.4%
Light fairly regular winds, possiable energy harvesting system. For summer ventulation look to the South West
SOUTH
NORTH
50 km/h
150° 165°
hrs
15°
108+ 30°
315°
0.6%
0.1% 1.0%
0.4%
0.3% 30 km/h 0.6%
97 86
54
0.0%
[Duration shown as percentages]
195°
SOUTH
150° 165°
43
60°
0.2%
0.0%
64
0.1%
0.3% 0.0% 0.6% 0.6% 0.2% 20 km/h 0.1% 1.1% 1.2% 1.0% 0.5%
210°
75
45°
1.2% 0.0% 1.1% 0.2% 1.8% 0.1% 2.1% 0.4%0.9%0.7% 1.1% 285° 2.3% 0.1% 10 km/h1.3% 0.7% 1.2% 0.3% 0.2% 0.0% 0.1% 1.8% 1.4% 1.2% 0.0% 0.7% 0.0% 0.0% 0.1% 0.2% 0.4% 0.4% 1.7% 1.5% 1.8% 2.8% 1.3% 0.1% 0.1% 1.6% 2.2% 0.9% 0.3% 0.1% 0.1% 0.0% WEST 0.1% 0.2% 0.8% 0.0% 0.1% 2.3% 2.2% 1.8% 0.3% 0.0% 0.2% 1.5% 0.8% 1.0% 2.0% 1.0% 0.2% 1.2% 1.5%2.9%2.4% 1.6% 1.3% 0.1% 0.3% 255° 0.9% 0.9% 3.1% 1.9% 0.2% 5.3% 1.1% 0.1% 0.0% 2.5% 1.0% 3.2% 1.0% 0.1% 1.6% 0.6% 0.1% 1.4% 240° 0.4% 0.2% 0.1% 0.5% 0.3% 0.1% 0.2% 0.3% 225° 135°
150° 195°
42
0.1%
0.1%
40 km/h 0.1%
0.1% 210°
49
45°
0.0%
330°
Location: Grand Rapids, USA (42.9°, -85.5°) Date: 1st September - 30th November Time: 00:00 - 24:00
26
60°
0.3%
285°
225°
195°
Prevailing Winds
33
0.2%
56
0.0%
[Duration shown as percentages]
66+
0.5% 30 km/h 0.8%
63
0.1%
210°
15°
315°
300°
105°
165°
330°
0.3%
0.4%
0.6%
0.1%
SOUTH
0.1% 30 km/h 0.1%
0.5%
0.2%
150° 195°
Location: Grand Rapids, USA (42.9°, -85.5°) Date: 1st June - 31st August Time: 00:00 - 24:00
EAST
0.1%
210°
71+
21 0.3% 0.6% 1.1% 14 0.0% 20 km/h 0.7% 1.0% 0.0% 0.9% <7 0.6% 0.1% 1.0% 0.6% 0.7% 0.6% 0.5% 0.6% 1.6% 1.2% 1.0% 0.6%1.3%0.6% 1.0% 285° 75° 1.4% 1.5% 10 km/h0.6% 0.7% 1.1% 1.6% 0.1% 0.0% 0.1% 1.1% 1.2% 0.0% 0.5% 0.3% 0.1% 0.2% 0.3% 0.2% 0.4% 0.5% 1.6% 2.1% 1.7% 2.1% 1.4% 0.1% 0.4% 1.7% 2.0% 2.3% 1.8% 2.2% 0.5% 0.5% 0.2% WEST EAST 0.0% 0.0% 1.1% 0.5% 0.6% 1.3% 2.3% 1.5% 0.1% 0.1% 0.4% 1.8% 1.2% 0.9% 1.0% 1.7% 0.3% 1.2% 1.0%1.6%1.0% 1.1% 1.2% 0.1% 0.9% 0.2% 255° 105° 1.0% 0.8% 1.8% 1.1% 0.5% 0.1% 3.3% 0.3% 0.4% 0.7% 0.2% 1.2% 0.2% 2.1% 0.4% 0.5% 1.0% 0.3% 0.2% 2.3% 240° 120° 0.9% 0.4% 0.3% 1.7% 0.2% 0.3% 0.1% 0.1% 0.0% 0.0% 225° 135°
<6
WEST
Wind Frequency (Hrs)
0.1%
12
0.8%
40 km/h 0.1%
0.0%
0.4%
300°
15° 30°
315°
19
hrs
330°
Location: Grand Rapids, USA (42.9°, -85.5°) Date: 1st March - 31st May Time: 00:00 - 24:00 0.0% © Weather Tool
25
60°
0.7%
0.0% 1.1% 0.2% 0.1% 1.4% 1.0% 1.9% 0.7% 0.6% 0.3% 1.9% 0.5% 1.6% 0.7%0.4%0.2% 0.9% 1.7% 0.5% 10 km/h0.9% 1.3% 1.9% 1.0% 0.1% 0.1% 0.1% 1.4% 1.3% 0.1% 0.7% 0.8% 0.1%
0.1%
345°
Wind Frequency (Hrs)
32
0.0%
0.6%
Prevailing Winds
DECISIONS:
NORTH
50 km/h
32 21 <10 75°
EAST
105°
120°
I. Grayson
C 1.3
Prevailing Winds
NORTH
50 km/h
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: Entire site has been developed prior Surrounding soils are sandy, use pilings to reach bedrock Low Earthquake Risk
78—Urban land Map Unit Setting Mean annual precipitation: 30 to 36 inches Mean annual air temperature: 45 to 48 degrees F Frost-free period: 140 to 150 days Map Unit Composition Urban land: 100 percent
81B—Urban land-Spinks complex, 0 to 8 percent slopes Map Unit Composition Urban land: 60 percent Spinks and similar soils: 35 percent Minor components: 5 percent Typical profile 0 to 10 inches: Sand 10 to 16 inches: Loamy sand 16 to 60 inches: Loamy sand, sand
I. Grayson
Earthquake Risk
C 1.4
Urban Land is defined as soil covered by fill material to a depth of 18” or more, or most of the soil has been cut away (Reybold and Matthews, 1976)
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: B
C
D
E
F
G
H
I
J
K
10
Steel framing with mtl. decking and concrete floors attached to steel collums sitting ontop piles ancored into bedrock
11
1
1
2
2
3
4
5
5
E
6
F
G
H
6
First thru Fith Floor Framing Plan 7
7
8
8
9
9
A
B
I
J
K
10
11
Ancor into bedrock because of nearness to river with potential for poor soil and erosion during flooding. Steel Pipe Lateral Cross Bracing shown in red Portions with soft story will utalize moment connections to satasfy seismic requirements Primary Collum Grid North South at 40’-0” East West at 30’-0”
D
I. Grayson
Structural Perspective
S 1.0
A
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: A
B
C
D
E
F
A
G
B
H
C
D
I
E
J
K
F
10
G
Steel Pipe Lateral Cross Bracing shown in red
11
1
H
1
I
J
K
10
Portions with soft story will utalize moment connections to satasfy seismic requirements
1
2
2
2 3
Primary Collum Grid North South at 40’-0” East West at 30’-0”
4
4 5
5
5
E
6
6
7
F
G
H
I
J
E
Seventh thru Thirteenth Floor Framing Plan 6
6
7
7
8
8
9
9
10
K
F
11
G
H
I
J
K
7
8
8
9
9
B
D
Sixth Floor Framing Plan
Apartment Structural Perspective A
B
D
I. Grayson
Office Corner Structural Perspective
S 1.1
A
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
10
DECISIONS:
UP
Lobby Leasing Office
Mercantile
Mercantile
Mercantile
Mercantile
Mercantile
Laundry
First Floor Plan I. Grayson
A 1.0
Gallery
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS:
Lobby
Laundry
Second thru Fifth Floor Plan I. Grayson
A 1.1
Office
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS:
Office
Lobby
Office
Lobby
Roof Access
Mechanical
Sixth thru Seventh Floor Plan
530 sqft
830 sqft
Laundry 1,000 sqft 600 sqft
I. Grayson
Detail Apartment Floorplans
A 1.2
Fifth Floor Plan
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
I. Grayson
A 1.3
DECISIONS:
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
I. Grayson
A 1.4
DECISIONS:
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: Building will utalize a mini split heating and cooling system Apartments opperable windows for enhanced climate control
Summer SolsticeSolar Study
Mini Split
Air Intake
System Output
I. Grayson
Mini Split System Layout per Apartment
M1.0
Winter Solstice Solar Study
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
DECISIONS: UP
The main water line should be installed below frost line There must be sufficient pressure at each fixture to ensure satisfactory operation Copper piping in order to prevent corrosion Hot water pipes should be insulated Photovoltaic water heating on sixth floor roof to suppliment boiler use
Vertical Plumbing Chase
I. Grayson
To Boiler
P 1.0
Water Supply Waste Line Hot Water
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
Fixture Calculations: Business
Men
Women
Occupancy (30)
15
15
Water Closet
1 / 15 = 1
1 / 15 = 1
Urinal
1
n/a
Lavatory
1 /15 = 1
1 /15 = 1
Drinking Fountain
1 / 75 = 1
Other
1 service sink
Mercantile
Men
Women
Occupancy (31)
16
16
Water Closet
1 / 100 = 1
1 / 100 = 1
Urinal
1
n/a
Lavatory
1 / 200 = 1
1 / 200 = 1
Drinking Fountain
1 / 100 = 1
Other
1 service sink
Determined using Illinois plumbing code, reference section 890.Appendix A
Occupancy
2-3
Water Closet
1
Lavatory
1
Drinking Fountain
n/a
Other
1 Double Sink, 1 Laundry tray or 1 Automated wash machine for each 4 units
P 1.1
Residential
DECISIONS: UP
Every room will be equiped with smoke detection and fire supression system, intergerated into a building system, with adequate audiableand visual warning. Wayfinding signage will be included capable of sustaining illumination during power outage. Located above and next to, near floor level, all exit points, and intersections.
Main Fire Panel
One hour fire rating will be acheved between mixed use occupancies. Level of Egress will bethe First Floor The enire building will be covered under a automated sprinkler system
First Floor Primary Fire Exit Smoke Detector Exit Sign Egress Routes
I. Grayson
Detail Apartment Floorplans Primary Egress Routes
FP 1.0
Primary Egress Routes
ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
I. Grayson ARC 541-001 ARC. SYSTEMS AND ENVIRONMENTS SOUTHERN ILLINOIS UNIVERSITY SCHOOL OF ARCHITECTURE FALL2013
AP 1.0
ISAAC GRAYSON
HIGH DENSITY HOUSING: HOW TO CREATE COMMUNITY, TO EASE PEOPLE INTO HIGH DENSITY URBAN HOUSING. CREATING SENCE OF COMMUNITY OWNERSHIP.
36% DUTCH HERITAGE
NOT INTERESTED IN EXPANDING SKYWALKS, WANTED TO ENCOURAGE PEOPLE TRAFFIC ON THE SIDEWALK
GENTRIFICATION
2012’ GRAND RAPIDS BREWING CO. 2010’ MCFADDEN’S SALOON 2009’ STELLA’S LOUNGE 2008’ HOPCAT
Dutchland
ACCESSED SITE ENTIRELY WITH TRANSIT, AND BEGAN THE FOCUS ON TRANSPORTATION. THE CITY WAS ALREADY MOVING TOWARDS PUBLIC TRANSPORTATION INFASTRUCTURE UPGRADES, WHILE ACKNOWLEDGING THE SOCIAL ASPECTS OF TRANSPORTATION. WANTING TO CREATE A DOWNTOWN THAT WILL ATTRACT PEOPLE OUT OF THE SPRAWL AND INTO A DOWNTTOWN URBAN SETTING BY PROMOTING CONVIENCE AND CREATING AMMENITIES. WHILE TAKING ADVANTAGE OF THE CURRENT ENTERTAINMENT AND ATTRACTIONS.
2
WEST ELEVATION
NORTH EAST PERSPECTIVE
IF YOUR NOT CLOSE ENOUGH TO HEAR THE RIVER, SHOULD YOU BE ABLE TO HEAR WATER WHEN YOU SEE THE RIVER
MULTI-TIER WALKING EXPERIENCE ALONG THE RIVER
E G A L I TA R I A N I S M - P I E RRECHARLES L’ENFANT, MAINTAIN THAT ALL HUMANS ARE EQUAL IN FUNDAMENTAL WORTH OR SOCIAL STATUS
SECOND FLOOR
FIFTH FLOOR
SEVENTH FLOOR
SOUTH WEST PERSPECTIVE
FIRST FLOOR
WEST APARTMENTS
EAST APARTMENTS
NORTH/SOUTH APARTMENTS
CREATING PUBLIC ACCESS TO THE RIVER AND PLANTING A COMMUNITY ADJACENT TO THIS SITE, AFFORDS THE OPPORTUNITY TO MORE INDIVIDUALS AND FAMILIES TO INTERACT WITH THE RIVER DEVELOPING A COMMUNITY IN THE URBAN CENTER OF GRAND RAPIDS
NORTH ELEVATION
NORTH WEST PERSPECTIVE
HEART
DECISIONS:
Final Comments:
A lot of work done this semester and very little to show for it. I was slow at making desisions for fear of making bad decisions, and as such did not allot myself enough time to complete a suitable project. Particularly one that I am happy with, it works but I am dont know for sure that it is what Grand Rapids needs.
Moving forward I need to work on making decisions quicker, hopefuly that will come more naturally as my knowledge basis grows.