||||||||||2010|air|conditioners|retail|catalogue|||||||||| cat_export2010_cons.indd 1
02/02/2010 16.58.36
cat_export2010_cons.indd 2
02/02/2010 16.58.55
www.argoclima.com
|PORTABLE|AIR|CONDITIONERS| Ultra
pages
4-5
Optimo
pages
6-7
Magico
pages
8-9
Mythiko
pages
10-11
Logyko
pages
12-13
O-Twin
pages
14-15
Ulisse - Floor split
pages
16-17
Reflexo DIY - DC Inverter Wall Split
pages
18-19
Feelyin DCI - Single Split
pages
20-21
Feelyin On-Off - Single Split
pages
22-23
Feelyin On-Off - Dual Split
pages
24-25
Rules for the application of the energy label
page
|DO-IT-YOURSELF|AIR|CONDITIONERS||
|single|&|dual|Split|air|conditioners|
26
3
cat_export2010_cons.indd 3
02/02/2010 16.58.56
www.argoclima.com
|||Ultra|||
12000 BTU/h (35째C - 80% RH Beyond A Class 2,87 E.E.R Made of anodized aluminum Top usable to put objects or ornaments... 3-way air diffusion Argo digital remote control Hidden wheels Ifeel function 41 dB(A) of quietness only 940 watt consumption No water tank Distilled water to be recovered
Made in Italy
4
cat_export2010_cons.indd 4
02/02/2010 16.58.58
www.argoclima.com
Ultra is a new Argo idea, with three ways for the air diffusion, able to introduce fresh air throughout the room, with an elegant top, without grids, buttons or displays….you can leave it in the living room all the year long and put on its top a flowerpot or other ornaments, while it cools or dries at your pleasure… its technological heart is silent and its dress is made of anodized aluminium … no one is ULTRA like it!
|||Ultra||| PRODUCT NAME Features Cooling capacity (35°C d.b.; 80% r.h.) Cooling capacity(1) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure (h.-m.-l.) Power supply Running consumption (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.)
Units BTU/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm
ULTRA Cooling 12.000 3,00 / 2,70 A 2,68 / 2,87 290-280-260 1,2 3 45-43-41 230/1/50 1,12 / 0,94 560 / 470 R410A 135 115 1 40 750x440x373
(1) Test conditions according to EN14511 standard
PRELIMINARY DATA - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
5
cat_export2010_cons.indd 5
02/02/2010 16.59.17
www.argoclima.com
|||optimo|| |white|&|black|
9000 9 & 11000 BTU/h (35째C - 80% R.H.) A Class Digital control panel Made in ABS 48 dB(A) of quietness 950 e 1250 watt consumption No water tank Distilled water to be recovered Remote control
6
cat_export2010_cons.indd 6
02/02/2010 16.59.27
www.argoclima.com
Optimo, absolutely new, young style, white or ultra shiny black, multifunctional, trendy, with backlit display characterizing its look… A look incredibly "teenagers"
|||optimo|9/11||| PRODUCT NAME Features Cooling capacity (35°C d.b.; 80% r.h.) Cooling capacity(1) (35°C d.b.; 24°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure (h.-m.-l.) Power supply Running consumption (35°C d.b.; 24°C w.b.) Annual energy consumption (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.)
Units BTU/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm
OPTIMO 9 Cooling 9.000 2,55 A 2,68 280-270-250 1,1 3 52-50-48 230/1/50 0,95 475 R410A 135 115 1 30 740x435x400
OPTIMO 11 Cooling 11.000 2,90 A 2,61 290-280-260 1,2 3 52-50-48 230/1/50 1,11 555 R410A 135 115 1 31 740x435x400
(1) Test conditions according to EN14511 standard
PRELIMINARY DATA - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
7
cat_export2010_cons.indd 7
02/02/2010 16.59.44
www.argoclima.com
|||magico|||
10300 BTU/h (35째C - 80% R.H.) A Class 2,78 E.E.R. Long range air throw High gloss ABS Hidden wheels Argo digital remote control Ifeel feature 41 dB(A) of quietness Only 925 watt consumption No water tank Distilled water to be recovered
Made in Italy
8
cat_export2010_cons.indd 8
02/02/2010 16.59.49
www.argoclima.com
It’s Magico, as it makes a hot day a pleasant day; with its capacity and its very long range air throw it grants a better air diffusion without making noise… magically. Moreover, in the cold season it can be used as a big airflow dehumidifier… in high humidity conditions it can extract from the air up to 51 litres of water a day!
|||magico||| PRODUCT NAME Features Cooling capacity (35°C d.b.; 80% r.h.) Cooling capacity(1) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.-m.-l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.)
Units BTU/h kW ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm
MAGIC0 9.2 Cooling 10.300 2,73 / 2,57 A/A 2,62 / 2,78 310-280-260 1,25 51 3 + Auto / 1 44-41 230/1/50 1,040 / 0,925 520 / 462 R410A 138 115 1 34 965x530x410
(1) Test conditions according to EN14511 standard
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
9
cat_export2010_cons.indd 9
02/02/2010 17.00.08
www.argoclima.com
|||mythiko|||
8600 BTU/h (35°C - 80% R.H.) ..Beyond A class Top level efďŹ ciency: 2,94 E.E.R. Long range air throw High gloss ABS Hidden wheels Argo digital remote control Ifeel feature 41 dB(A) of quietness Only 700 watt consumption No water tank Distilled water to be recovered
Made in Italy
10
cat_export2010_cons.indd 10
02/02/2010 17.00.13
www.argoclima.com
Mythiko, a champion in energy efficiency with the right capacity; able to cool and dehumidify without compromises in winter ... Mythiko never leaves you!
|||mythiko||| PRODUCT NAME Features Cooling capacity (35°C d.b.; 80% r.h.) Cooling capacity(1) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.)
Units BTU/h kW ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm
MYTHIKO / MYTHIKO 8 Cooling 8.600 2,25 / 2,06 A/A 2,81/ 2,94 310-260 1,0 42 2/1 44-41 230/1/50 0,800 / 0,700 400 / 350 R410A 138 115 1 30 860x482x376
(1) Test conditions according to EN14511 standard
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
11
cat_export2010_cons.indd 11
02/02/2010 17.00.39
www.argoclima.com
|||logyko|||
83 BTU/h – 9700 BTU/h – 11300 BTU/h 8300 (35°C - 80% R.H.) A class for all three models E.E.R.: 2,62 - 2,79 - 2,87 Digital control panel Made of ABS 48 dB(A) of quietness 765 watt – 860 watt – 940 watt consumption No water tank Distilled water to be recovered
Designed Italy Made ininItaly
12
cat_export2010_cons.indd 12
02/02/2010 17.00.50
www.argoclima.com
Logyko, available in three versions with capacity up to 11300 BTU/h; all this is Logyko! Choosing it is very easy and using it is even more; equipped with everything you need, Logyko is compact, discreet and keeps its promises.
|||logyko||| PRODUCT NAME Features Cooling capacity (35°C d.b.; 80% r.h.) Cooling capacity(1) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure (h.-m.-l.) Power supply Running consumption (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.)
Units BTU/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm
LOGYKO 7.5 Cooling 8.300 2,20 / 2,00 A/A 2,62 / 2,61 270-260-240 1,0 3 52-50-48 230/1/50 0,840 / 0,765 420 / 383 R410A 135 115 1 30 750x450x375
LOGYKO 9 Cooling 9.700 2,62 / 2,40 A/A 2,62 / 2,79 280-270-250 1,1 3 52-50-48 230/1/50 1 / 0,86 500 / 430 R410A 135 115 1 30 750x450x375
LOGYKO 11 Cooling 11.300 3,00 / 2,70 A/A 2,68 / 2,87 290-280-260 1,2 3 52-50-48 230/1/50 1,12 / 0,94 560 / 470 R410A 135 115 1 31 750x450x375
(1) Test conditions according to EN14511 standard
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
13
cat_export2010_cons.indd 13
02/02/2010 17.01.10
www.argoclima.com
|||o-twin|||
9920 BTU/h & 13670 BTU/h A Class for both models High efficiency: 3,26 Argo digital remote control 33 dB(A) of quietness 890 watt – 1250 watt consumption Automatic condensate vaporization Small condensing case ““AeroQuip” AeroQuipp quick connectors for “do-it-yourself” installation Piping length up to 6 meters
Made in Italy
14
cat_export2010_cons.indd 14
02/02/2010 17.01.17
www.argoclima.com
Oscar Twin, the split portable air conditioner equipped with a small condensing case, easy to be disconnected and re-connected through special quick connectors; great comfort without air hose, even to be installed in a ďŹ xed position, like a standard split. Its features allow to reach 14,000 BTU/h... a big capacity for large areas!
|||o-twin|||| PRODUCT NAME Features Capacity Energy label class E.E.R. Air flowrate (h.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)
Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm
OSCAR TWIN 11A Cooling 2,91 9.920 2.500 A 3,26 420-300 1,0 3 + Auto / 1 37-35-33 45 230/1/50 0,890 445 R410A 2 2-4 1,2 5,2 40/9,5 800x470x310 435x440x230
OSCAR TWIN 14A Cooling 4,01 13.670 3.450 A 3,21 460-350 1,6 3 + Auto / 1 40-39-39 42 230/1/50 1,250 625 R410A 2 2-4 1,2 5,2 41/13 800x470x310 490x525x250
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
15
cat_export2010_cons.indd 15
02/02/2010 17.01.31
www.argoclima.com
|||ulisse|||
10160 BTU/h-13640 B BTU/h – cooling capacity 11390 BTU/h - heating capacity A Class for all three models Argo digital remote control 29 dB(A) of quietness Automatic condensate vaporization Small condensing case “AeroQuip” “AeroQuii quick connectors for “do-it-yourself” installation Piping length up to 6 meters
Made in Italy
16
cat_export2010_cons.indd 16
02/02/2010 17.01.37
www.argoclima.com
Great capacity and functionality in just 24 cm depth! All this and much more is the “evergreen” Ulisse Argo. Quiet, efficient and very practical to use thanks to its multifunction remote control with digital 24 hours timer ... You set it and don’t think about it anymore! Ulisse Cools, Heats, Dehumidifies... It’s extremely quiet and doesn’t take too space! A product actually not replaceable!
|||ulisse||| PRODUCT NAME Features Capacity Energy label class E.E.R. /C.O.P. Air flowrate (h.)/(h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)
Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm
ULISSE 10CLA Cooling 2,98 10.160 2.560 A 3,22 370 1,2 3 + Auto / 1 36-36-34 45 230/1/50 0,925 463 R410A 2 2-4 1,2 5,2 44/9,5 790x580x245 435x440x230
ULISSE 10HLA Cooling Heating 2,98 3,34 10.160 11.390 2.560 2.870 A A 3,22 3,67 370 1,2 3 + Auto / 1 35-31-29 39 230/1/50 0,925 0,910 463 R410A 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250
ULISSE 13PCLA Cooling 4,00 13.640 3.440 A 3,21 400-375-335 1,9 3 + Auto / 1 37-36-34 42 230/1/50 1,25 625 R410A 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
17
cat_export2010_cons.indd 17
02/02/2010 17.02.00
www.argoclima.com
|||reflexo|diy|dci|9/12|||
FULL DC Inverter technology 180° - 9 &12 KBTU/h Cooling capacity up to 12700 BTU/h Heating capacity up to 15850 BTU/h Efficiency in cooling up to 4,57 Efficiency in heating up to 5,48 Beyond AA ClassArgo digital remote control 23 dB(A) of quietness Room temperature to be set from +10°C to +32°C Outdoor operating limits from -15°C to +43°C Special quick connectors on both indoor and outdoor unit Integrated piping and electrical connection kit Pre-charged refrigerant pipe up to 5 meters
Made in Italy
18 8
cat_export2010_cons.indd 18
02/02/2010 17.02.08
www.argoclima.com
Capacity and technology together with extremely elegant design and metalized look make Reflexo a very important component in the modern environment in which even the smallest detail is studied and designed according to the personal taste of persons who pretend more and more for their home ... Obviously, in perfect Made in Italy style ...
|||reflexo|diy|dci|9/12|| PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity
nominal (min.-max.)
Energy label class E.E.R. /C.O.P. nominal (min.-max.) Air flowrate Indoor (h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.-sl.) Sound pressure Outdoor (max.) Power supply Power input nominal (min.-max.) Annual energy cons.-cooling(500h)-Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)
Units kW BTU/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh
mm(inch") mm(inch") m m gr/m m m Kg mm mm
REFLEXO 09 DIY REF 09 DIY AEI 09 DIY Cooling Heating 2,85 (1,05-3,15) 3,24 (1,15-4,0) 9.730(3.580-10.750) 11.060(3.930-13.650) A A 3,65 (4,57-2,86) 4,10 (5,48-3,20) 450-400-370 1,2 4/auto 39-36-29-23 37 230/1/50 0,78 (0,23-1,1) 0,79 (0,21-1,25) 390 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 8/35 270x805x205 540x700x265
REFLEXO 12 DIY REF 12 DIY AEI 12 DIY Cooling Heating 3,25 (1,1-3,7) 3,40 (1,25-4,65) 11.100(3.760-12.630) 11.600(4.270-15.870) A A 3,32 (4,4-2,78) 3,82 (5,21-3,0) 470-430-390 1,5 4/auto 39-36-29-23 40 230/1/50 0,98 (0,25-1,33) 0,89 (0,24-1,55) 490 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 8 / 35 270x805x205 540x700x265
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
19
cat_export2010_cons.indd 19
02/02/2010 17.02.33
www.argoclima.com
|||feelyin|DCI||
DC C Inverter technology 9 & 12 KBTU/h Cooling up to 14000 BTU/h Heating up to 17400 BTU/h Cooling efficency up to 4,4 Heating efficency up to 4,7 AA Class Digital remote control 32 dB(A) of quietness Active carbon filters Photocatalytic Bio Filter ABS elegant design
20 0
cat_export2010_cons.indd 20
02/02/2010 17.02.42
www.argoclima.com
DC Inverter technology, performance and controls that ensure the best conditions of temperature for the highest level of comfort..... And what about the incredible silence? This means Feelyin DCI... This is what we mean as consumption reduction!
|||feelyin|dc|inverter|| PRODUCT NAME Indoor unit Outdoor unit
FeelYin 9 DCI
FeelYin 12
FY DCI 09 UI
FY DCI 12 UI
FY DCI 09 UE
Features
Units
Cooling/Heating capacity nominal (min.-max.)
Cooling
FY DCI 12 UE Heating
kW
2,50(1,2-4,0)
2,90(1,4-5,0)
BTU/h
8.550(4.100-13.650)
9.900(4,8-17.100)
Cooling
Heating
3,20(1,30-4,10)
3,80(1,50-5,10)
10.920(4.440-14.000) 13.000(5.120-17.400)
kcal/h
2.150(1.032-3.440)
2.500(1.204-4.300)
2.752(1.118-3.530)
Energy label class
ABCDEFG
A
A
A
A
E.E.R. /C.O.P. nominal (min.-max.)
(kW/kW)
3,29(4,4-2,9)
3,63(4,7-3,1)
3,23(2,9-4,1)
3,62(3,0-4,4)
3.270(1.290-4.390)
m³/h
450-400-320
Dehumidification
l/h
0,8
1,2
Fan speeds (Indoor / Outdoor)
n°
3/1
3/1 40-37-34
Air flowrate Indoor (h.-m.-l.)
Sound pressure Indoor
(h.-m.-l.)
Sound pressure Outdoor (h.) Power supply Power input nominal (min.-max.) Annual energy cons.-cooling(500h)-Dir.2002/31/CE Compressor type
500-450-380
dB(A)
38-35-32
dB(A)
50
51
V/Ph/Hz
230/1/50
230/1/50
kW kWh
0,76 (0,27-1,36) 0,8 (0,3-1,6) 380 (135-680) Rotary
0,99(0,34-1,43) 495(170-715)
1,05(0,35-1,70) Rotary
R410A
R410A
Liquid pipe diameter
mm(inch")
6,35(1/4")
6,35(1/4")
Gas pipe diameter
12,7 (1/2")
Refrigerant type mm(inch")
9,52(3/8")
Max. pipe lenght with gas standard charge
m
7
7
Max. pipe lenght
m
10
10
Max. height between units (Outdoor on top)
m
5
5
Max. height between units (Indoor on top)
m
5
5
Net dimension Indoor (H./W./D.)
mm
290x800x186
290x800x186
Net dimension Outdoor (H./W./D.)
mm
520x770x280
520x770x280
Kg
10/32
10/37
Net weight Indoor / Outdoor
PRELIMINARY DATA - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
21
cat_export2010_cons.indd 21
02/02/2010 17.03.03
www.argoclima.com
|||feelyin||||
Cooling capacity 9200 – 12000 17750 – 24250 BTU/h Heating capacity 9720 – 12960 20500 – 26650 BTU/h A Class Standard on/off optimized technology Digital remote control 34 dB(A) of quietness Active carbon filters Photocatalytic BioFilter ABS elegant design
22
cat_export2010_cons.indd 22
02/02/2010 17.03.09
www.argoclima.com
White, beautiful and modern ... easy to program, reliable, complete of everything you need for your comfort. Feelyin is the typical air conditioner that works so well to become part of your daily habits...
|||feelyin|on/off|| FeelYin 9
PRODUCT NAME
FeelYin 12
FeelYin 18
Indoor unit
F Y 09 UI
F Y 12 UI
F Y 18 UI
Outdoor unit
F Y 09 UE
F Y 12 UE
F Y 18 UE
Features Cooling/Heating capacity
F Y 24 UI F Y 24 UE
Units
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
kW
2,7
2,85
3,5
3,8
5,20
6,00
7,10
7,80
BTU/h
9200
9720
12000
12960
17.750
20.500
24.250
26.650
kcal/h
2300
2450
3010
3270
4.470
5.160
6.100
6.700
Energy label class
ABCDEFG
A
E.E.R. / C.O.P.
(kW/kW)
3,25
m3/h
Air flowrate Indoor (h.m.l.)
FeelYin 24
A
A
3,61
3,33
450-400-320
B
A
3,42
3,22
500-450-380
Heating
A
A
B
3,64
3,23
3,53
850-700-650
1100-980-880
Dehumidification
l/h
0,8
1,2
2,2
3
Fan speeds (Indoor / Outdoor)
n째
3/1
3/1
3/1
3/1
dB(A)
40-37-34
40-37-34
43-40-37
50-46-43
Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Power input Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type
dB(A)
50
51
56
58
V/Ph/Hz
230/1/50
230/1/50
230/1/50
230/1/50
kW kWh
0,83 415
0,79 Rotary
Refrigerant type
R410A
1,05 525
1,11 Rotary R410A
1,615 807,5
1,65 Rotary R410A
2,2 1.100
2,21 Rotary R410A
Liquid pipe diameter
mm(inch")
6,35(1/4")
6,35(1/4")
6,35(1/4")
9,52 (3/8")
Gas pipe diameter
mm(inch")
9,52(3/8")
12,7 (1/2")
12,7(1/2")
15,88 (5/8")
Max. pipe lenght with gas standard charge
m
7
7
7
7
Max. pipe lenght with gas additional charge
m
15
15
10
15
Max. height between units (Outdoor on top)
m
4
4
5
8
Max. height between units (Indoor on top)
m
8
8
5
8
mm
290x800x186
290x800x186
293x860x203
330x1080x220
mm
500x665x295
552x835x310
680x845x310
680x845x310
Kg
10/26
10/37
12/50
15/60
Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Net weight Indoor / Outdoor
PRELIMINARY DATA - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
23 2
cat_export2010_cons.indd 23
02/02/2010 17.03.27
www.argoclima.com
|||feelyin|dual|||
Cooling capacity (BTU/h): 9220+9220 - 9220+12000 - 11770+11770 9220+92 Heating capacity (BTU/h): 9930+9930 - 9930+12630 - 12290+12290 9930+99 Standard on/off optimized technology Digital remote control 40 dB(A) of quietness Active carbon ďŹ lters Photocatalytic Bio Filter ABS elegant design
24
cat_export2010_cons.indd 24
02/02/2010 17.03.32
www.argoclima.com
High capacity, combined with a wide range of features make special this incredibly simple dual split Feelyin Dual: install it and you'll forget it!
|||feelyin|dual||| PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.) Sound pressure Outdoor (h.) Power supply Power input Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Net weight Indoor / Outdoor
Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW kWh
mm(inch") mm(inch") m m m mm mm Kg
FeelYin 9+9 2 x FY 09 UI D FY 18 UE D Cooling Heating 2,7+2,7 2,91+2,91 9.220+9.220 9.930+9.930 2.322+2.322 2.500+2.500 A B 3,21 3,42 450-400-320 0,8 3 + Auto/1 38-35-32 57 230/1/50 0,84+0,84 0,85+0,85 840 Rotary R410A 6,35(1/4")/6,35(1/4") 9,52(3/8")/9,52(3/8") 10 5 5 290x800x186 680x813x310 10 / 56
FeelYin 9+12 FY 09 UI D+ FY 12 UI D FY 21 UE D Cooling Heating 2,7+3,52 2,91+3,7 9.220+12.000 9.930+12.630 2.322+3.030 2.500+3.182 B D 3,02 2,87 450-400-320/500-450-380 0,8 / 1,2 3 + Auto/1 38-35-32 / 40-37-34 58 230/1/50 0,84+1,22 0,85+1,45 1.030 Rotary R410A 6,35(1/4")/6,35(1/4") 9,52(3/8")/12,7(1/2") 10 5 5 290x800x186 680x813x310 10 / 56
FeelYin 12+12 2 x FY 12 UI D FY 24 UE D Cooling Heating 3,45+3,45 3,6+3,6 11.770+11.770 12.290+12.290 2.970+2.970 3.096+3.096 C D 2,82 2,82 500-450-380 1,2 3 + Auto/1 40-37-34 59 230/1/50 1,225+1,225 1,275+1,275 1.225 Rotary R410A 6,35(1/4")/6,35(1/4") 12,7(1/2")/12,7(1/2") 15 7 7 290x800x186 680x813x310 10 / 62
PRELIMINARY DATA - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
25
cat_export2010_cons.indd 25
02/02/2010 17.03.51
www.argoclima.com The energy label shows the belonging class: “A” class is the best one and it is assigned on the basis of specific tables that put in relation the thermal capacity and the energy consumption for each product. The ratios used to assign the energy class are the following: E.E.R. = Energy Efficiency Ratio, is the relation between the cooling capacity (kW) and the power consumption in cooling mode (kW) C.O.P. = Coefficient Of Performance, is the relation between the heating capacity (kW) and the power consumption in heating mode (kW)
|Rules|for|the|application|of|the|energy|label|
Example of energy label: 1) generic part - coloured
2) ) specific part - black/white
Our air conditioners are fully compliant to the most recent European regulations concerning the reduction of the energy consumption and the lessening of the atmosphere pollution. The energy labels, indicating the energy efficiency class, have been introduced by the European Directive 2002/31/EC, which makes reference to the standard EN14511 for the determination of the energy class. The energy labels must be applied on products (air-conditioners air-to-air up to 12 kW of cooling capacity) in exposition on the points of sale, with the objective of giving information on the energy efficiency of the air-conditioners to the final user. The energy label is divided in two parts: one is coloured and generic, the other, adhesive and black and white, contains the technical and efficiency data of each product or combination of indoor/outdoor units and must be sticked on the one, in the empty space. Our company supplies both parts of the energy label: the one, coloured, is delivered directly to the points of sale (responsible for the application of the energy label on the products in exposition), the other (black and white) with technical and efficiency data is put directly inside the product carton box at the end of the production process (to make easier for the seller the application of the right label). If the black & white part of the energy label is lost, each point of sale can immediately download it from the dedicated section in our Web Site, or ask for it to our Marketing Department.
26
cat_export2010_cons.indd 26
02/02/2010 17.03.54
cat_export2010_cons.indd 27
02/02/2010 17.04.07
702010008-02/10
www.argoclima.com
argo clima
S.p.A.
headquarter Via Varese, 90 21013 Gallarate (VA) ITALY Tel: +39 0331 755111 Fax: +39 0331 776240 www.argoclima.com
The manufacturing company doesn’t assume any responsibility for mistakes or omissions contained in this catalogue and reserves the right to make at any time, even without notice, any change considered suitable for technical or commercial purposes to its products.
28
cat_export2010_cons.indd 28
Argo is a brand of argo clima S.p.A a company of AER.FI. group, European leader in Air Conditioning, Heating and Air Treatment.
02/02/2010 17.04.08