The company, our products and our reference markets

Organisation and services

Argoclima S.p.A. specialises in the supply of products and services for the air conditioning, heating and air treatment market. Our range of products are almost all designed and manufactured in the Argoclima factories (in Italy and France), they provide state-of-the-art solutions that stand out for their advanced technology, design and modular nature. These features allow all manner of problems to be quickly resolved and offer excellent solutions with top energy efficiency performance. In addition to the products normally on offer through retail channels (portable and wall-mounted air conditioning systems, dehumidifiers and supplementary heating), our company also offers a range of ARGO brand products. These include direct expansion air-conditioning systems ranging from 2.2 to 150 kW with COP levels of above 5. Segmentation by heat output allows for the quick and easy identification, differentiation and positioning of the range of products, which focus on applications ranging from private homes to office buildings and from small and medium-sized retail outlets to shopping centres... The direct expansion systems all make use of Full DC Inverter technology to create systems with many dozens of indoor units, with over 300 metres of piping and height differences between units of over 50 metres.

Argoclima S.p.A. is specifically organised to best support the needs of various types of customers: the needs of Retail customers, for example, are sometimes similar and sometimes very different to those of Installation Technicians, Wholesalers and B2B operators. Private consumers can also find answers to their questions both via conventional means and services as well as via new computer technologies: our website, www.argoclima.com, provides a large amount of information at different levels of expertise and access in order to satisfy any type of request. An extensive network of After-Sales Service Centres and the European Spare-Parts Centre guarantee a high level of After-Sales Service. The After-Sales Service Centres are linked-up via Internet to specific web applications used to manage the various phases of scheduled or corrective maintenance operations. In order to meet the particular needs of installers who specialise in the sale of centralised systems, Argoclima S.p.A. offers a full-range of services through a wellstructured organisation which reports to the Systems Division:

Condensing units and terminal units, designed using the most advanced design and manufacturing techniques, they work brilliantly within a wide range of outdoor temperatures from -20°C to +43°C. Their mechanical properties facilitate handling and installation, thus reducing the cost of building systems. They can also be controlled using the most advanced building control systems (CIB/BMS), via local, centralised and/or remote controllers with web and fieldbus interfaces (lonworks...).

r JOTQFDUJPO WJTJUT BOE OFFET BOBMZTJT XJUI UIF DVTUPNFS BOE PS designer; r QSPQPTBM BOE PS DIPJDF PG UIF CFTU UFDIOPMPHJDBM TPMVUJPO GPS UIF specific context/system design as a whole; r TVQQPSU JO UIF JOTUBMMBUJPO TUBSU VQ QIBTF PG UIF TZTUFN r "GUFS 4BMFT 4FSWJDF XJUI UBJMPS NBEF NBJOUFOBODF DPOUSBDUT r PO HPJOH UFDIOJDBM DPNNFSDJBM TVQQPSU GPS VQEBUJOH BOE JG OFDFTTBSZ adapting to new technologies. In order to provide the above-mentioned services, Argoclima S.p.A. has a team of qualified technicians and sales personnel, who receive regular training on technological and regulatory matters. Argoclima S.p.A.’s logistics centre is located near the town of Brescia and manages the entire logistics process for incoming and outgoing goods for customers throughout Europe and beyond. Argoclima S.p.A. has been in the marketplace for 80 years, a level of experience that provides absolute assurance of the company’s capacity for Innovation, Quality and Service in the manufacture of the finest Italianmade products.

www.argoclima.com


www.argoclima.com

04

page

43

page

51

page

55

page

67

page

83

ON OFF F

page


I SERIES

A complete system, not just a simple split unit‌

iSERIESTM, a multi-functional integrated system iSERIESTM is the commercial name for the HVAC system (heating, ventilation and air conditioner) manufactured by Argoclima S.p.A.; it comprises of a series of components that allow the creation of mono and multi-split systems, in air/air, air/water and mixed air/air plus air/water configurations, with or without the generation of domestic hot water and combination with thermal and photovoltaic solar systems.

is a system based entirely on renewable energy sources, designed to provide heat even in Nordic areas in installations operating in outside temperatures as low as 30 degrees below zero, and to provide cool air in desert regions in installations operating at over 50 degrees, multifunctional and highly energy efficient.

offers truly integrated applications for comfort, scalability, expandability and modularity; multi-processor electronics control the 180 SVPWM DC Inverter, which modulates the heat energy according to real needs, from a minimum of 10% up to a maximum of 130% of nominal output.

is conceived, designed and built entirely in Italy, in the Argoclima laboratories and main factory in Gallarate in the province of Varese, 40 Km north of Milan and only 5 Km from the international airport of Milan Malpensa.

4

www.argoclima.com


I SER R IES

Outdoor units is a split system with a feature that has never been seen before: the same outdoor units are both mono and multi, they do not change based on the application and are compatible with all the indoor units in the iSERIESTM range. From 2012 six outdoor units will be available to satisfy the needs of the most demanding customers, covering a modulated heat output range from 0.6 kW to over 13 kW; the range will be further extended up to over 22 kW.

HEATING COOLING

AEI1G30

AEI1G40

AEI1G50

AEI1G65

AEI1G80

AEI1G110*

*available in 2012

www.argoclima.com

5


I SERIES

Indoor units The indoor units in the iSERIESTM range are divided into categories by heat output and by application. There are four heat output categories: - size A for heat output up to 4 kW - size B for heat output up to 7 kW - size C for heat output up to 11 kW - size D for heat output up to 14 kW Thanks to the iSERIESTM sophisticated inverter regulation system, the classic references of rated power outputs are replaced by a greater flexibility and the number of product codes and references is reduced by 70%. WALL

FLOOR CEILING

FLOOR

SLIM DUCTED

CASSETTE

DUCTED

HYDROKIT

The application categories are: Air/Air type: t wall mounted t two-way floor mounted t floor mounted - reversible for ceiling mounting

t floor mounted - reversible for recessed ceiling mounting (slim ducted) t cassette for false ceilings t mono and multi-zone ductable

Air/Water type: t Hydrokit for floor-mounted systems, radiators and fan coils

t Domestic hot water

MIXED AIR/AIR + AIR/WATER APPLICATION

All indoor units can be connected individually or used in combination with other units, based on thermal balance criteria aimed at creating an integrated system that fully satisfies the requirements of the end customer.

6

R410A H2O

www.argoclima.com


I SERIES SER IES

Applications Great flexibility in the combination of different types and categories of indoor units allows many different applications to be realised that before required the use of different systems that were difficult to integrate with one another. Below is a summary of possible applications that should give installation technicians an idea of the wide range of possibilities offered by the iSERIESTM system: Air/air mono-split, from a typical high quality residential split unit system to solutions for small service sector applications, offices, restaurants, bars... also multi-zone systems with ductable units... or for special applications such as containers, motor homes... Air/water mono-split, this solution is commonly used for heating and cooling with floor mounted systems, but can also be used with low temperature radiators or fan coils, even in combined and multi-zone combinations. Air/air multi-split, a classic solution for the summer air conditioning of apartments and villas but also for heating and cooling offices, shops and small service sector applications in general. Air/water multi-split mixed with air/air, an unusual solution that offers a extremely wide spectrum of applications. With this system we can create a floor mounted system with two zones and at the same time air condition a cellar and loft conversion with an air/air unit suited to these spaces: wall mounted, floor mounted with two-way flow or maybe even ductable. is a primary and integrated system for heating, air conditioning, air treatment and domestic hot water production, entirely based on a sophisticated technique employing high efficiency inverter heat pumps, a renewable energy source that can be combined with thermal and photovoltaic solar power. The flexibility of the iSERIESTM system satisfies the requirements of the residential market and small service sector applications: from the most simple high quality split unit systems to multi-zone systems with floormounted systems, to multi-split systems for apartments, offices and public spaces...

www.argoclima.com

7


I SERIES

Outdoor units Technical specifications for outdoor units Refrigerant flow/volume regulation via centralised PID control system acting on a vectorial inverter and electronic expansion valves.

SVPWM180°, vectorial inverter with sensor less 180° PWM; this is a purely sinusoidal inverter with extremely low electromagnetic noise emissions. It provides constant control of the permanent magnet synchronous motors throughout their 360° revolution (180°+180°). This optimises torque, a key factor in motor control for compressors in particular, thus providing excellent performance in terms of output, efficiency and quietness, especially at low rotational speeds. Multi-processor platform based on the client/server model, with an operating system controlling the motors and microprocessors dedicated to application management fitted in the outdoor and indoor units.

Standard RS485 bus communication via screened bi-polar cable: the highest level of communication security is ensured thanks to a balanced interface normally used for industrial applications. The bus provides an address for each unit and can be wired either as a bus or in a star configuration starting from the outdoor unit. This allows the system to be expanded and developed whilst still ensuring compatibility between units. One advantage of the RS485 bus is the possibility of supplying the units in the system with power either in a centralised manner or each to unit independently. The range of outdoor operating temperatures is very wide; regulations require full operation from -15°C to +43°C but the iSERIESTM exceeds this: we have heat pump installations working at up to -30°C in Nordic areas and cooling installations in desert regions operating in outside temperatures of over 50°C. The iSERIESTM control system is able to protect itself and implements operational shut down only when the temperature reaches -50°C, practically absurd conditions for a heat pump.

8

www.argoclima.com


agents and equipped with certified hardware protection circuits.

heater coil, controlled by the electronics and software in the outdoor unit controller, cuts in to prevent the compressor Liquid from freezing when the system is inactive in stand by and outdoor temperatures require it.

Diagnostic system for the easy identification of any technical faults, with data logging for technicians accessed directly from bus RS485.

Ice prevention at the base of the outdoor unit; a dedicated electric heater coil is fitted indoor the metal base of the outdoor unit and is activated by the software when temperature conditions require in order to prevent the formation of ice. Non Stop Operation and Intelligent Defrost; the prevention and elimination of ice on the heat exchanger in the outdoor unit is an essential process for an air-condensed heat pump. Thanks to its special control algorithms, iSERIESTM carries out this task in an intelligent way and, unless strictly necessary, without inverting the refrigerating cycle and therefore with a continuous (albeit reduced) heat supply to the heated area.

Compact and sophisticated electronics, built using SMD technology, resin coated for protection from atmospheric

I SERIES SER IES

Compressor Liquid ice prevention; a dedicated

BootLoader for software updates for outdoor and indoor units, with no risk of losing flash eprom data.

Automatic restart following power black outs, with the same operating parameters as before and restart protected against excess pressure.

Heat exchangers in high quality copper/ aluminium with inorganic hydrophilic aluminium, which does not emit odours and provides top performance in heat exchange output and efficiency.

Maximum installation exibility, thanks to the specifications governing difference between units.

pipe

length

and

height

Rust-proof treatment, providing the best protection against corrosion and rust formation even under extreme conditions such as in saline mist.

www.argoclima.com

9


I SERIES

AEI1G30, the smallest outdoor unit in the iSERIES

TM

range, designed for mono-split applications but not only for hiwall and not only for air/air applications (EMIXTM). AEI1G30 is very compact, its heat output is nearly 4 kW and it is built to withstand the worst atmospheric conditions without corrosion. It has a plastic front grille resistant to UV rays covering the entire surface and a silver logo with the brand and a Made in Italy logo. The elegant pipe cover completes the unit, which is one of the most compact and quiet available on the market.

AEI1G40

50

and are built using the same chassis for mono/dual solutions up to 6 kW. Its size provides high performance whilst still remaining quite compact. Corrosion resistant metals prepared for the worst atmospheric conditions and plastics resistant to UV rays complete these particularly quiet outdoor units.

AEI1G65, despite its heat rating of over 8.5 kW, this unit is compact, strong and quiet. Like the other units in the iSERIESTM range, this unit is designed to withstand the worst conditions. It can be used for mono, dual and triple solutions with a wide range of air and/or water indoor units.

AEI1G80

, mono, dual, triple and quadruple configurations in a single outdoor unit compatible with all the multifunction indoor units in the iSERIESTM range, and with a heat output of up to 11 kW. Corrosion resistant metals impervious to saline mist, UV ray resistant plastic and concealed pipe attachments complete this excellent and quiet unit.

AEI1G110*, over 13 kW in a compact chassis with a single fan, for mono, dual, triple and quadruple applications with high heat outputs, this unit is suitable for fully integrated primary solutions for heating and cooling offices and family homes. Corrosion resistant metals impervious to saline mist and UV ray resistant plastic; a top-of-the-range outdoor unit, quiet and flexible with an excellent heat output.

*available in 2012

10

www.argoclima.com


I SERIES SER IES

Technical Data

Outdoor units AEI1G30 Specifications Capacity nominal (min-max) Energy class E.E.R. / C.O.P. Fan speed Sound pressure O.U. (max.) Electrical power supply Power input Annual energy consumption (500h)-Dir. 2002/31/EC Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Length of pipes (with standard charge) Length of pipes (with additional charge) Maximum height difference IU/OU (outdoor unit above or below) Net weight Net dimensions (H./W./D.)

Units kW ABCDEFG (kW/kW) N° dB(A) V/Ph/Hz kW kWh

Cooling 2,65 (1,37-3,6) A 3,96

Heating 2,75 (0,93-3,32) A 4,82 self modulating 40 230/1/50

0,67 335

0,57 Single Rotary R410A 6,35(1/4”) 9,52(3/8”) 7,5 15 10 35 540x700x265

mm (inch") mm (inch") m m m Kg mm

AEI1G40 Specifications Capacity nominal (min-max) Energy class Nominal E.E.R. / C.O.P. Fan speed Sound pressure O.U. (max.) Electrical power supply Power input Annual energy consumption (500h)-Dir. 2002/31/EC Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Length of pipes (with standard charge) Length of pipes (with additional charge) Maximum height difference (outdoor unit above) Maximum height difference (indoor unit above) Net weight Net dimensions (H./W./D.)

Units kW ABCDEFG (kW/kW) N° dB(A) V/Ph/Hz kW kWh

Cooling 3,50 (1,25-4,25) A 3,68

Heating 3,90 (1,20-5,20) A 4,19 self modulating 44 230/1/50

0,950 475

0,930 Rotary R410A 6,35(1/4”) 9,52(3/8”) 15 15 (no additional charge) 7 7 39 630x895x345

mm (inch") mm (inch") m m m m Kg mm

The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CE N.B. Provisional data used at the time of printing

www.argoclima.com

11


I SERIES

Technical Data AEI1G50B Specifications Capacity nominal (min-max) Energy class E.E.R. / C.O.P. nominal value (min.-max.) Fan speed Sound pressure O.U. (max.) Electrical power supply Power input nominal (min-max) Annual energy consumption (500h)-Dir. 2002/31/EC Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Length of pipes (with standard charge) Length of pipes (with additional charge) Length of pipes per unit (with standard charge) Length of pipes per unit (with additional charge) Maximum height difference IU/OU (outdoor unit above or below) Net weight Net dimensions (H./W./D.)

Units kW ABCDEFG (kW/kW) N° dB(A) V/Ph/Hz kW kWh

Cooling 4,55 (0,84-5,18) A 3,35 (4,20-2,93)

Heating 5,19 (0,95-6,00) A 4,29 (5,94-3,43) self modulating 41 230/1/50

1,360 (0,200-1,770) 680

1,210 (0,160-1,750) Twin Rotary R410A 6,35(1/4”) 9,52(3/8”) 15 tot. Dual / 7.5 Mono 30 tot. Dual / 20 Mono 12 (Dual) 25 (Dual) 20 tot. (max. 10m I.U.) 56,5 630x895x345

mm (inch") mm (inch") m m m m m Kg mm

AEI1G65 Specifications Capacity nominal (min-max) Energy class E.E.R. / C.O.P. nominal value (min.-max.) Fan speed Sound pressure O.U. (max.) Electrical power supply Power input nominal (min-max) Annual energy consumption (500h)-Dir. 2002/31/EC Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Length of pipes (with standard charge) Length of pipes (with additional charge) Length of pipes per unit (with standard charge) Length of pipes per unit (with additional charge) Maximum height difference IU/OU (outdoor unit above or below) Net weight Net dimensions (H./W./D.)

Units kW ABCDEFG (kW/kW) N° dB(A) V/Ph/Hz kW kWh

Cooling 6,50 (1,57-8,71) A 3,25 (3,78-3,00)

Heating 7,30 ( 1,82-8,67) A 4,32 (5,05-3,82) self modulating 40 230/1/50

2,0 (0,415-2,90) 1000

1,69 (0,36-2,27) -

Twin Rotary R410A 6,35(1/4”) 9,52(3/8”) / 12,77(1/2”) 30 tot. Dual-Triple / 20 mono 45 tot. Dual-Triple / 35 mono 25 (Dual) 20 (Triple) 30 (Dual) 25 (Triple) 10 tot. Dual-Triple / 10 mono 64 735 x 1030 x 400

mm (“) mm (“) m m m m m Kg mm

AEI1G80 Specifications Capacity nominal (min-max) Energy class Nominal E.E.R. / C.O.P. Fan speed Sound pressure Electrical power supply Power input Annual energy consumption (500h)-Dir. 2002/31/EC Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Length of pipes (with standard charge) Length of pipes (with additional charge) Length of pipes per unit (with standard charge) Length of pipes per unit (with additional charge) Maximum height difference IU/OU (outdoor unit above or below) Net weight Net dimensions (H./W./D.)

Units kW ABCDEFG (kW/kW) N° dB(A) V/Ph/Hz kW kWh

Cooling 8,15 (1,60-9,62) A 3,70 self modulating 47 230/1/50 2,20 1100

2,18 -

mm (“) mm (“) m m m m m

Twin Rotary R410A 6,35(1/4”) 3 x 9.52 (3/8”) / 1 x 12.77 (1/2”) 30 tot. 65 tot. multi / 50 mono 30 50 30 tot. multi / max. 10 per unit

Kg mm

73 835x1190x400

The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CE N.B. Provisional data used at the time of printing

12

Heating 9,21 ( 1,70-11,20) A 4,22

www.argoclima.com


I SERIES SER IES

Combinations APPLICATIONS AEI1G 30

AEI1G 40

AEI1G 50B

AEI1G 65

AEI1G 80

X

X

X

X

X

Air/Water

X

X

X

Air/Air and Air/Water

X

X

X

Air/Air

AIR / AIR COMBINATIONS AEI1G 30

AEI1G 40

AEI1G 50B

AEI1G 65

AEI1G 80

A

A

B

B

B

C

C

Mono Mono Dual

A+A

A+A*

A+A

Dual

A+B

A+B

A+B

B+B

A+C

Dual Dual

B+B

Triple

A+A+A

A+A+A

Triple

A+A+B

A+A+B

Triple

A+B+B

Quadruple

A+A+A+A

Quadruple

A+A+A+B

*Connect to ports A and B inserting the integrated accumulator using the bypass provided with AEI1G65

AIR/ WATER COMBINATIONS AEI1G 50B

AEI1G 65

AEI1G 80

HKBE

HKBE

HKCE

SIZE A

SIZE B

SIZE C

AEI1G 30

AEI1G 40 mono

AEI1G 50B

AEI1G 65

AEI1G 80

multi

multi

multi

Wall

AWIA S8 W/B

mono

Wall

AWIA S87 W/B

mono

Wall

AWIA S7F

mono

multi

multi

multi

Floor

AFIA S11

mono

mono

multi

multi

multi

Floor/Ceiling

FCIA S8

mono

mono

multi

multi

multi

Floor/Ceiling-recess SDIA S8

mono

mono

multi

multi

multi

Cassette

ASIA S8

mono

mono

multi

multi

multi

Wall

AWIB S9

mono/multi

mono/multi

mono/multi

Floor

AFIB S11

mono/multi

mono/multi

mono/multi

Floor/Ceiling

FCIB S9

mono/multi

mono/multi

mono/multi

Floor/Ceiling-recess

SDIB S9

mono/multi

mono/multi

mono/multi

Cassette

ASIB S9

mono/multi

mono/multi

mono/multi

Hydraulic module

HK BE

mono

mono/multi

Ducted

ADIC S10

mono

mono

Cassette

ASIC S10

Hydraulic module

HK CE

mono

mono/multi mono/multi mono/multi

www.argoclima.com

13


I SERIES

Maximum pipe lengths and maximum distances between outdoor unit and indoor units

AEI 1G 30/40

L

AEI 1G 50

The AEI1G50 outdoor unit, equipped with a standard charge of refrigerant (preloaded in the factory), allows for a maximum pipe length of 7.5 metres in mono configuration and up to 15 metres in dual configuration. By adding refrigerant (20 grams per metre in mono configuration and 15 grams per metre in dual configuration), the maximum length is extended to 20 metres in mono configuration and 30 metres in dual configuration. In the event of dual configurations it should be remembered that each of the two indoor units can be positioned at a different distance from the outdoor unit. If the maximum distance of the first indoor unit from the outdoor unit is 12 metres, the second indoor unit must be placed at a maximum distance of 3 metres from the outdoor unit. This is because the maximum pipe length (15 metres), must never be exceeded. Of course in the event of additional refrigerant, the maximum distance of the first indoor unit can be up to 25 metres, and the second, 5 metres. Similar concepts can also be applied to outdoor units AEI1G65 and AEI1G80, and the same shall apply for future outdoor units in the iSeries range. The table below combined with the diagram allows you to easily identify the maximum values for the pipe lengths / maximum distances between outdoor and indoor units. Standard charge

L1 Outdoor unit

L2

L

ConďŹ guration

Tot L

Additional charge

Max L

Tot L

Max L

AEI1G30

mono-split

15

-

15

-

AEI1G40

mono-split

15

-

15

-

AEI1G50B

mono-split

7,5

-

20

-

AEI1G50B

dual-split

15

12

30

25

mono-split

20

-

35

-

AEI 1G 65 AEI1G65

dual-split

30

25

45

30

triple-split

30

20

45

25

mono-split

30

-

50

-

dual-split

40

30

65

30

AEI1G80

L1 L2

30

65

30

30

65

30

Height differences between outdoor and indoor units and between indoor units L

AEI 1G 80

L1 L2 L3 L4

L

14

40 40

Tot L = total length of pipes, given by the sum of pipe lengths for each indoor unit Max L = maximum pipe length per single indoor unit, whether it is no. 1, 2, 3‌.

L3

(Ln) Individual lengths (L) Individual lengths

triple-split quadruple-split

The maximum height difference between the outdoor unit and indoor unit/s does not depend on the distances and/or the pipe lengths described above. It depends instead on the total height difference between the various units (both outdoor and indoor) that make up the split or multi-split system. In multi-split configurations there is also a relationship between the maximum height difference between the outdoor unit and indoor units (sum of height differences). For example, if the total maximum height difference between the outdoor unit and indoor units as declared by the manufacturer is 10 metres and the maximum height difference between the two indoor units is 5 metres, in a dual configuration with the outdoor unit on the ground floor, the first indoor unit can be installed at up to 7 metres above (or below), but the second unit may only be fitted a maximum of 3 metres above (or below). This is so as not to exceed 10 metres (7+3 = 10) and at the same time to not exceed the 5 metres of maximum height difference between the two indoor units (7-3 = 4). On the other hand, it is not possible to position the first indoor unit at 8 metres and the other at 1 metre from the outdoor unit. This is because even though the sum of height differences is less than the maximum height difference of 10 metres (8+1 = 9), the height difference between the two indoor units would however reach 7 metres, exceeding the maximum permitted height difference. Where the same dual configuration outdoor unit is positioned at a height in between the two indoor units, the first indoor unit can also be installed one metre below the outdoor unit. In this case the second indoor unit can be installed at a maximum of 4 metres above the outdoor unit because the maximum height difference of 5 metres between indoor units cannot be exceeded. With this type of installation the two indoor units are in fact usually placed at a height difference of 2.5 metres with respect to the outdoor unit.

Maximum height difference (sum of height differences) AEI1G30 and AEI1G40 = 7 m AEI1G50 = 20 m AEI1G65 = 30 m AEI1G80 = 40 m

www.argoclima.com

Maximum height difference between two indoor units (only for multi-split systems) AEI1G50 = 5 m AEI1G65 = 5 m AEI1G80 = 5 m


I SERIES SER IES

Indoor units Technical speciďŹ cations for indoor units Every indoor unit in the iSERIESTM system has its own specific features but there are also features common to all units in the range, these are listed here below.

Dynamic Cold Draft, an active protection system preventing the emission of air that is noticeably colder than ambient temperature during heating operation and particularly during defrost stages. Antifreeze, this protection system prevents the formation of ice on the indoor unit heat exchanger when the system is working in cooling mode and there are particular temperature and humidity conditions. Temperature settings from +10°C to +32°C both in cooling and heating modes; the units can therefore be used for indoor low ambient temperature applications such as in cellars, server rooms and radio stations... They can also be used to maintain a minimum temperature in spaces that are unused during weekends such as offices and shops, or places that are unused during the week such as holiday homes in the mountains or at the seaside...

iFEEL function, a comparative function that ensures optimum temperature settings based on the values read at the remote control sensor, the sensor in the indoor unit and the resulting ambient temperature stratification conditions, which are always different from one room to another.

Wide range IR receiver, this receives the remote control signal even under difficult conditions. It is equipped with a noise canceller for complete immunity from interference generated by low energy consumption fluorescent bulbs. Hardware or software addressing of units for recognition on communication bus RS485. Remote control addressing for the management of one or more grouped indoor units, up to a maximum of four units. This function is useful where several indoor units are situated in a large space (open space offices, hotel reception rooms, restaurants, etc...), and need to be controlled either by one or several remote controls.

www.argoclima.com

15


I SERIES

Five operating modes: automatic, cool, heat, dehumidify and fan. Night Function for maximum operating economy during the night without compromising comfort. High Power Function, when maximum power is required straight away. Active/passive air ďŹ lters: all air/air units are equipped with washable mesh filters and can be fitted with an activated charcoal filter; some units are fitted as standard with a titanium dioxide photocatalytic anti-bacterial filter, activated via remote control by invisible dedicated LEDs fitted indoor the unit, fully compliant with EU regulations concerning UV emissions. Intelligent air ap control based on operating mode, which when combined with the iFEEL function offers the maximum in comfort to counter air temperature stratification effects.

Automatic fan (or manual fan) to provide maximum heat (when required) and the right amount of cool, without creating annoying cold air draughts or excessive amounts of hot air.

Timer for programming the operating times of each individual indoor unit, with weekend* and holiday* controls. Wireless and wired universal remote control for all iSERIESTM indoor units, with multi-function keypad, LCD graphic display, wall mount and wired* connection. Elegant ergonomic interface with discreet micro LEDs that can be deactivated via remote control, particularly useful for those that prefer complete darkness at night.

Protective grilles, which offer the maximum in safety in compliance with standard EN60335. This allows for installation even at low heights where children could otherwise potentially touch moving parts such as fans and motors.

* this last function is available with the new remote control for 2012

16

www.argoclima.com


does not emit odours and provides top performance in heat exchange output and efficiency.

Plastic materials with high quality looks and functional properties (improved thermal stability). As green as possible thanks to the use of noble acrylics such as PMMA, pure ABS for the parts on view and recycled PS for the internal structures. Hydrokit with heat exchanger with plates made from AISI316L stainless steel for heat exchange between the refrigerant and water, built-in module for additional electrical heating, automatically controlled by software in three steps, controlled by thermal-magnetic switches that can be deactivated manually, safety thermostats, pressure switch, high performance water pump and water flow rate control device. Controller for hydrokit , with climatic curve control and control of the various applications of the hydronic circuit (floor, fan coils, radiators, mixed...), with the possibility of separation into areas with different settings. Wide range of hydronic accessories to suit various different system configurations. Generation of domestic hot water using the EMIXTM module, the internal unit for the iSERIESTM system, which is able to provide hot water from a thermo-dynamic source all year round. EMIXTM will become available in 2012 and will have its own illustrated manual explaining the functions and operating modes in connection with the iSERIESTM system.

www.argoclima.com

17

I SERIES SER IES

Heat exchangers in high quality copper/aluminium with inorganic hydrophilic aluminium, which


I SERIES A8, a wall-mounted indoor unit with a distinctive design, ideal for modern spaces and also compatible with more conventional styles. Combines easily with many different styles and colours found in the ofďŹ ce and at home.

18

www.argoclima.com


I SERIES SER IES

84 mm

A8 is available in size A, and at 21 dB(A) is extremely quiet. The unit is equipped with an active photocatalytic filter, which is able to significantly reduce the bacterial load in the environment thanks to the titanium dioxide oxidation process activated by completely concealed special UV LEDs that are fully compliant with EU standards.

A8 is designed to provide high energy efficiency and has one very important feature: it can be recess fitted using the dedicated wall mounting kit.

The front panel made from PMMA, a prized acrylic material, is dual coated on the back and available in satin white or carbon fibre black; the transparent border along the panel perimeter creates a bright frame that responds to colour changes in the environment. The horizontal central strip in silver conceals the noiseless remote control signal receiver and the extremely elegant blue and white micro LEDs. These are very discreet and can also be deactivated using a function developed specifically for those that prefer complete darkness at night.

A8 is also easy to install, thanks to the possibility of being able to connect the refrigerant pipes either to the horizontal compartment or to the right side; the bilateral condensation discharge pipe and the possibility of fitting the unit at below two metres in height (thanks to the protection grille), complete the flexibility of this high quality indoor unit.

Titanium Dioxide ďŹ lters and Air Quality

This filter uses the oxidising power of Titanium Dioxide (TiO2) to destroy bacteria and inhibit viruses. It also effectively reduces dust and dirt particles and helps to prevent unpleasant odours.

very quiet:

only 21 dB(A) Heat exchanger in odourless inorganic hydrophilic aluminium Organic compounds, odours, bacteria, viruses...

www.argoclima.com

19


I SERIES Elegant and discreet, available in sizes A (A7) and B (A9), an indoor unit to suit all tastes, suitable for all settings both in terms of design and heat output.

20

www.argoclima.com


I SERIES SER IES The casing for model A7/A9 is treated using a photo engraving technique to obtain a satin effect on the plastic, this is done during the injection stage and no further treatments are applied. You can see the quality of the material and manufacturing process used with the naked eye, this sets the A7/A9 unit apart from other white wall-mounted indoor units.

A7/A9 allows condensation discharge to the right or left, it has LEDs that can be deactivated and washable filters, it is compact and easy to install.

Mesh ďŹ lters with optional odour-capturing activated charcoal ďŹ lter

The optional activated charcoal filter is comprised of a layer of synthetic material folded to increase the filtering surface area and treated with a professional anti-bacterial solution, combined with an activated charcoal mesh. Activated charcoal is a material mainly made up of carbon in the form of graphite micro crystals treated in such a way as to create a porous structure with a vast internal surface area. When the forced air flow passes through the filter element, the charge of static energy allows the filter to trap even the smallest particles of pollutants and allergens, down to a size of 0.01 microns. The activated charcoal layer attracts and absorbs the organic molecules responsible for unpleasant odours, eliminating them completely.

very quiet: only

23 dB(A)

Heat exchanger in odourless inorganic hydrophilic aluminium

www.argoclima.com

21


I SERIES A refined console for low wall installation, at just a few centimetres from the floor and with two-way air flow, up and down, for maximum comfort in summer and winter.

22

www.argoclima.com


I SERIES SER IES AF is very sophisticated, it is equipped with a DC motor (DCM), and in stand by consumes only 70 mW. It is equipped with a humidity sensor that is used to differentiate the use of the two air flows based on the sensed temperature index. t LED operation can be deactivated by remote control

AF is available in sizes A and B, whilst still maintaining the same structure and dimensions. It filters and purifies the air using a washable mesh filter and a titanium dioxide photocatalytic filter that can be activated via remote control. At 22 dB(A), the unit is extremely quiet thanks to its speciallydesigned structure and two tangential fans managed by inverter-controlled DC motors. AF is the newest model and is also the first in its class within the iSERIESTM range of indoor units. Compact and made from pure ABS, it is well suited for installation under windows or mid-wall, occupying the smallest space possible. t LED operation can be deactivated by remote control

very quiet: only

22 dB(A)

www.argoclima.com

23


I SERIES FC and SD, two versions of the same unit, reversible for oor or ceiling installation, they can be ďŹ tted on view (FC) or concealed in dedicated spaces (SD) created using plasterboard or wood or in false ceilings.

24

www.argoclima.com


I SERIES SER IES t Easy installation and condensation discharge t Easy maintenance

t Fits anywhere!!!

FC and SD are available in sizes A and B, whilst still maintaining the same structure and dimensions. They are easy to install and maintain thanks to washable filters that are easy to access on both versions. SD, despite being designed for recessed and therefore concealed fitting, can be controlled by the iSERIESTM universal remote control in either wireless or wired mode.

t Ceiling installation t LED operation can be deactivated by remote control

t Condensation anti-drip system

ONLY 18.9 cm!!!

The depth of only 19 cm and quiet operation at 24 dB(A), make these two iSERIESTM units an excellent solution for villas, offices, hotel rooms, restaurants and public spaces etc.

very quiet:

only 24 dB(A) Heat exchanger in odourless inorganic hydrophilic aluminium

t Vertical installation

www.argoclima.com

25


I SERIES AS, the cassette unit for false ceilings that we can often observe above our heads in public spaces, ofďŹ ces, shops and restaurants. It is certainly also suitable for private dwellings as it was originally designed with this application in mind, however it is more common to see it used in service sector applications.

26

www.argoclima.com


I SERIES SER IES t Easy installation and discharge t Perfect integration!

t Flocked anti-condensation aps

Available in sizes A and B, and with slightly larger dimensions (80x80) also in size C, this unit is built with great attention to detail: insulated metal, four flocked anti-condensation flaps, carefully calibrated fan, quality plastic grille and a large filter that is easy to access for cleaning. AS is designed for air exchange with the outside, which is mandatory for installations in public spaces, and is equipped with a condensation discharge pump.

t Body in anti-corrosion metal

t Simple and convenient maintenance

As with all the other units in the iSERIESTM range, AS is controlled using the universal remote control. In the contexts in which this cassette unit is installed the remote control is able to express some of its more special features, such as the option for wired connection instead of wireless control and the ability to control groups of units, which is very useful for open space offices, restaurants, and hotel reception areas.

very quiet:

only 35 dB(A) Heat exchanger in odourless inorganic hydrophilic aluminium ASIA/ASIB www.argoclima.com

ASIC

27


I SERIES AD, the high prevalence ductable unit, to be combined with purpose built plenums with or without the aid of the three-way duct built into the unit.

28

www.argoclima.com


I SERIES SER IES t Plenum for channelling the air into 3 spaces

t Removable ďŹ lters

t Perfect distribution

t Standard integration

AD, as with the cassette units, this unit is mainly designed for use in service sector applications and is built with great care from carefully selected materials. Available in size C, it is equipped with high quality centrifugal fans and a condensation discharge pump. It is also fitted with washable filters that are easy to access and can be controlled using the iSERIESTM universal remote control in wired or wireless mode.

www.argoclima.com

29


I SERIES Hydrokit HKE, available in sizes B and C, is the indoor unit to be combined with the iSERIESTM outdoor units to create heating and air conditioning solutions with oor, wall or ceiling mounted radiator systems.

The iSERIESTM system is able to control air-condensed indoor units simultaneously with Hydrokit to create a mixed air/water and air/air system. The wide range of possibilities for use both as a mixed system and as a conventional split inverter air/water heat pump system, should be very interesting to installation technicians who will discover the unique versatility of the iSERIESTM system.

Hydrokit, installed indoor the building as if it were a wall-mounted boiler, is equipped with high quality plate heat exchangers made from AISI316L stainless steel, a high efficiency water pump and a module for additional electrical heating with three power steps (2+2+2 kW). The system is fully controlled by the unit’s software according to heat requirements but can also be manually deactivated using the dedicated thermal-magnetic switches. A pressure gauge displays the water pressure in the circuit and there are also safety pressure switches and a device that controls the water flow rate.

30

www.argoclima.com


t heating and air conditioning with mono and multi-zone floor, wall or ceiling mounted radiator systems; t heating using low temperature radiators, also in combination with floor mounted radiator systems; t air conditioning using hydronic terminal units or fan coils, also in combination with floor mounted radiator systems.

It should be remembered that the installation of air/air indoor units in the same area as a floor mounted radiator system avoids the need to install dehumidifiers for the cooling cycles and accelerates arrival at the desired set point in both heating and cooling modes. Hydrokit is provided with an area controller, a sensor to be fitted on the building exterior and a water filter. The controller manages both the climatic curve and the entire hydronic system; it can be connected to other similar controllers to manage separate areas with the aid of the multi-zone module. Other accessories for the hydronic system are available on request to satisfy special requirements.

EMIXTM is the innovative indoor unit in the iSERIESTM range, able to provide domestic hot water from a thermo-dynamic source all year round, i.e. independently of the system’s operating mode. EMIXTM works simultaneously with the other units in the system, both in air/air and air/water configurations or in mixed air/air and air/water combinations, an absolute first.

EMIXTM will become available in 2012 and will have its own illustrated operating manual demonstrating the possible combinations with other indoor units and connection configurations with outdoor units in the iSERIESTM range.

www.argoclima.com

31

I SERIES SER IES

In addition to mixed air/water and air/air configurations, unique to the iSERIESTM system, Hydrokit is also able to control many hydronic applications:


I SERIES

Universal Digital Remote Control All air conditioner operating parameters can be controlled from the remote control: operating modes (auto or cooling only, heat pump only, dehumidification only, fan only), 1h and 24h timer, desired temperature, ambient temperature reading, TiO2 filter activation (where fitted), fan speed, flap oscillation for optimum air distribution in the room and economy or night functions. Many operations can be set automatically or managed when needed, including the deactivation of the LED indicators for those that prefer complete darkness at night.

32

www.argoclima.com


I SERIES SER IES

t Dual transmitter t Wide range of operation. The presence of a dual infrared transmitter ensures a very wide range of operation: just place the remote control where you like for “made-to-measure” comfort in that area.

t Built-in temperature sensor.

t Wide display with graphic symbols and alphanumeric indicators.

t iFeel function a comparative function that ensures optimum temperature settings based on the values read at the remote control sensor, the sensor in the indoor unit and the resulting ambient temperature stratification conditions, which are always different from one room to another.

t iFlap Function The air flow can be released into the room in an “intelligent” way based on whether the unit is set to heating or cooling mode, thanks to a special system that controls the oscillation of the horizontal flap.

t )J QPXFS UVSCP GVODUJPO when maximum power is required straight away.

Adjustable set point from 10° to 32° C both in cooling and heat pump modes

t .VMUJ EJSFDUJPOBM The remote control can be set to control four different units in an open space for unified control, or customised according to temperature, timer, operating mode, and all other functions.

One for all

One to One

www.argoclima.com

33


I SERIES

Technical Data

Indoor units

MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

AWIAS8 W/B 250-410-480-600

m³/h

250-410-480-600

Dehumidification

l/h

1,5

1,5

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.)

dB(A)

21-29-36-39

21-29-36-39

V/Ph/Hz

230/1/50

230/1/50

kW

0,031

0,031

Current consumption

A

0,13

0,13

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

mm (“)

9,52(3/8”)

9,52(3/8”)

kg

10,5

10,5

mm

305x895x195/110

305x895x195/110

Electrical power supply Power input

Net weight I.U. Net dimensions I.U. (H./W./D.D of recess-fitted I.U.)

34

AWIAS87 W/B

www.argoclima.com


I SERIES SER IES

Dati Tecnici

MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

AWIA S7F

AWIB S9 410-580-710-880

m³/h

390-430-470-450

Dehumidification

l/h

1,5

2,0

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.)

dB(A)

23-29-36-39

29-35-43-47

V/Ph/Hz

230/1/50

230/1/50

kW

0,031

0,086

Current consumption

A

0,13

0,40

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

mm (“)

9,52(3/8”)

12,7(1/2”)

kg

8

12

mm

270x805x215

285x995x240

AFIA S11

AFIB S11 615-665-760-830

Electrical power supply Power input

Net weight I.U. Net dimensions I.U. (H./W./D.)

MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

m³/h

450-500-590-700

Dehumidification

l/h

1,3

2,3

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.)

dB(A)

22/26/30/37

28/30/37/45

V/Ph/Hz

230/1/50

230/1/50

kW

0,017

0,019

Current consumption

A

0,07

0,08

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

mm (“)

9,52(3/8”)

12,7(1/2”)

kg

18

18

mm

600x750x220

600x750x220

Electrical power supply Power input

Net weight I.U. Net dimensions I.U. (H./W./D.)

www.argoclima.com

35


I SERIES

Dati Tecnici

MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

FCIB S9 615-665-760-830

m³/h

450-500-590-700

Dehumidification

l/h

1,3

2,3

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.)

dB(A)

24-26-30-37

35-40-46-49

V/Ph/Hz

230/1/50

230/1/50

kW

0,037

0,075

Current consumption

A

0,17

0,33

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

mm (“)

9,52(3/8”)

12,7(1/2”)

kg

23,5

23,5

mm

680x900x190

680/900/190

SDIA S8

SDIB S9 470-520-600-680

Electrical power supply Power input

Net weight I.U. Net dimensions I.U. (H./W./D.)

MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

m³/h

300-340-380-470

Dehumidification

l/h

1,3

3,3

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.)

dB(A)

24-26-30-37

35-40-46-49

V/Ph/Hz

230/1/50

230/1/50

kW

0,037

0,075

Current consumption

A

0,17

0,33

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

mm (“)

9,52(3/8”)

12,7(1/2”)

kg

25

25

mm

585x890x190

585x890x190

Electrical power supply Power input

Net weight I.U. Net dimensions I.U. (H./W./D.)

36

FCIA S8

www.argoclima.com


I SERIES SER IES MODEL Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

ASIA S8

ASIB S9

ASIC S10

m³/h

470-500-600-700

500-530-630-750

680/840/1020/1140

Dehumidification

l/h

1,2

2,3

3,6

Fan speed

Auto + 3 remote control settings

Auto + 3 remote control settings Auto + 3 remote control settings

dB(A)

35-37-40-44

35-37-40-44

41/44/45/46

V/Ph/Hz

230/1/50

230/1/50

230/1/50

kW

0,087

0,087

0,175

Current consumption

A

0,41

0,41

0,77

Liquid pipe diameter

mm (“)

6,35(1/4”)

6,35(1/4”)

15,88(5/8”)

Gas pipe diameter

mm (“)

9,52(3/8”)

12,7(1/2”)

12,7(1/2”)

kg

19

20,5

22

Net dimensions I.U. (H./W./D.)

mm

296x575x575

296x575x575

338x860x860

Net dimensions of grille (H./W./D.)

mm

41x730x730

41x730x730

41x730x730

Sound pressure I.U. (sl.-l.-m.-h.) Electrical power supply Power input

Net weight

MODEL

ADIC S10

Specifications

Units

Air flow rate I.U. (sl.-l.-m.-h.)

m³/h

500/600/700/1000

Dehumidification

l/h

2,5

Fan speed

Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) Electrical power supply Power input

dB(A)

35-40-46-49

V/Ph/Hz

230/1/50

kW

0,114

Current consumption

A

0,51

Liquid pipe diameter

mm (“)

6,35(1/4”)

Gas pipe diameter

mm (“)

12,7(1/2”)

Net weight I.U. Net dimensions I.U. (H./W./D.)

kg

23,5

mm

680 x 900 x 190

www.argoclima.com

37


I SERIES

Type

Applications

Outdoor Units

domestic hot water

air/water mono-split

AEI1G65

AEI1G80

AEI1G110

Wall

Floor

Floor/Ceiling

Floor/Recess-Fitted Ceiling

Cassette

Ducted

x

x

x

x

x

x

x

x

x

x

x

Unit for DHW

AEI1G50B

x

HydroKit

AEI1G40

x

x

x

x

x

x

x

two floor areas

x

x

x

x

x

one fan coil area

x

x

x

x

x

one floor area and one fan coil area

x

x

x

x

x

one floor area and one radiator area

x

x

x

x

x

one radiator area

x

x

x

x

x

one radiator area and domestic hot water

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

air/air and domestic hot water

x

x

x

x

x

x

x

x

x

x

air/air and air/water

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

air/air, air/water and domestic hot water

38

x

one floor area

air/air multi-split

mixed multisplit

AEI1G30

air/air mono-split

Indoor Units

www.argoclima.com

x

x


I SERIES SER IES

iSERIESTM applications

AEI1G50B + HKBE water temperature at inlet/outlet

outdoor air temperature Minimum

Heating 30/35 °C

+7 °C

30/35 °C

-7 °C

45/50 °C

+7 °C

45/50 °C

-7 °C

40/45 °C

+7 °C

40/45 °C

-7 °C

20/25 °C

+7 °C

20/25 °C

-7 °C

+35 °C

7/12 °C

+35 °C

Maximum 6,23

Kw

0,95

5,27

COP

*

4,14

Kw

*

4,02

COP

*

2,38

*

Kw

*

4,78

5,27

COP

*

2,96

*

4,73

Kw

*

3,10

3,65

COP

*

1,92

*

Kw

*

4,93

5,80

COP

*

3,31

*

Kw

*

3,70

4,35

COP

*

2,3

*

Kw

*

6,20

7,30

COP

*

5,36

*

Kw

*

3,16

3,72

COP

*

2,73

*

Minimum

Nominal

Maximum

Kw

0,84

4,50

5,73

EER

*

3,57

*

Kw

*

3,15

3,47

EER

*

1,97

*

Cooling 18/23 °C

Nominal

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests. In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided. Preliminary data at catalogue date

www.argoclima.com

39


I SERIES

iSERIESTM applications

AEI1G65B + HKBE water temperature at inlet/outlet

outdoor air temperature Minimum

Nominal

Maximum

Kw

1,82

8,20

9,33

COP

*

4,2

*

Heating 30/35 °C

+7 °C

30/35 °C

-7 °C

50/55 °C

+7 °C

50/55 °C

-7 °C

40/45 °C

+7 °C

40/45 °C

-7 °C

20/25 °C

+7 °C

20/25 °C

-7 °C

Kw

*

4,99

5,41

COP

*

2,64

*

Kw

*

5,65

6,50

COP

*

2,63

*

Kw

*

3,50

3,89

COP

*

1,58

*

Kw

*

7,10

7,60

COP

*

3,2

*

Kw

*

4,20

4,55

COP

*

2,06

*

Kw

*

8,70

9,45

COP

*

5,48

*

Kw

*

4,50

5,26

COP

*

2,7

*

Minimum

Nominal

Maximum

Kw

1,57

6,00

7,00

EER

*

3,6

*

Kw

*

5,20

5,64

EER

*

2,58

*

Cooling 18/23 °C

+35 °C

7/12 °C

+35 °C

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests. In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided. Preliminary data at catalogue date

40

www.argoclima.com


I SERIES SER IES

iSERIESTM applications

AEI1G80B + HKCE water temperature at inlet/outlet

outdoor air temperature Minimum

Nominal

Maximum

Kw

1,70

9,42

11,30

COP

*

4,03

*

Heating 30/35 °C

+7 °C

30/35 °C

-7 °C

50/55 °C

+7 °C

50/55 °C

-7 °C

40/45 °C

+7 °C

40/45 °C

-7 °C

20/25 °C

+7 °C

20/25 °C

-7 °C

Kw

*

5,65

6,65

COP

*

2,5

*

Kw

*

6,40

7,53

COP

*

2,49

*

Kw

*

3,90

4,60

COP

*

1,49

*

Kw

*

8,10

9,55

COP

*

3,06

*

Kw

*

5,18

6,10

COP

*

1,95

*

Kw

*

10,24

12,05

COP

*

5,03

*

Kw

*

5,12

6,02

COP

*

2,56

*

Minimum

Nominal

Maximum

Kw

1,60

7,98

9,40

EER

*

4,01

*

Kw

*

6,87

8,10

EER

*

2,84

*

Cooling 18/23 °C

+35 °C

7/12 °C

+35 °C

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests. In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided. Preliminary data at catalogue date

www.argoclima.com

41


I SERIES

Notes:

42

www.argoclima.com


XF FE ETTO

Attractive, slim, versatile and… with no outdoor unit Made from ABS with a high-gloss pearl finish, Xfetto has a modern yet linear design that fits well in any space. www.argoclima.com

43


XF FE ETTO

AIR / AIR Only 2 holes in the wall are needed‌ to connect the air-condensed Xfetto model with the outside, as long as the holes are in a perimeter wall. Xfetto air/ air houses an outdoor unit within its single case and in order to operate correctly requires a constant exchange of air with the outside because it uses air to cool the condenser. This air exchange takes place via two 16 cm holes (1 intake hole and 1 outflow hole), to be made in the installation wall, which therefore must be a perimeter wall. Thanks to the special grilles the unit can be installed very easily even from indoor the room, through walls or structures up to 2 metres thick or directly onto large windows with no loss of performance... Xfetto is also designed to allow recessed wall installation and in this instance its visible depth is reduced to only 10 centimetres. When Xfetto operates in cooling mode or dehumidification only, the condensation is released by internal evaporation in the condenser: therefore there is no need to provide a condensation discharge pipe for the cooling-only models. Condensation discharge is however required for models with a heat pump, even though its use is limited to heat pump operation. The condensation can be drawn either indoor or outside the room using the dedicated duct indoor the device’s chassis.

Air condensed

16 cm

only 26 cm thick 44

www.argoclima.com


COP up to 4.68

Can also be installed on non-perimeter walls Xfetto water-condensed still eliminates the problem of the outdoor unit by housing it within its single case, but it uses water instead of air to cool the condenser. This solution has the advantage of not requiring holes in the wall and thus allows the device to be installed on any type of wall, perimeter or not. The advantages of this application include: great energy efficiency (COP up to 4.68), low power consumption (630 watts to achieve a heat output of over 3 kW) and extremely quiet operation thanks to the fact that the condenser, being water-cooled, has no ventilation system. The water-condensed version of Xfetto consumes just one cubic metre of water per day (less than one euro’s worth). Unique and special, it provides solutions for niche applications that arise much more often than you may think... From residences in historic buildings with large supplies of water, to systems with cooling towers, heat pumps and/or boilers on closed-circuit loops even when controlled by BMS, such as Lyon Airport.

Mains water use

Closed circuit water use

The ideal application for areas with strict regulations governing modifications to building facades and without limitations on water use. The system nevertheless has a low level of water consumption that may reach up to one cubic metre of water per day under normal summer operating conditions, with a daily cost of less than one euro. It only requires connection to two water pipes, inflow and outflow.

Xfetto can also operate as a terminal in a closed circuit water loop system with water at 30°C in accordance with EN14511 specifications. The water used to cool the condenser is fed into a circuit and drawn to a cooling tower where it is cooled and then reused by the device.

Water condensed

Key

Mains water

Recirculated water

Tap Flow rate valve 0.5 mm mechnical mesh filter Water inlet hose Flow switch Solenoid Water outlet hose Water heat exchanger Water inlet Water outlet

www.argoclima.com

45

XF FE ETTO

WATER / AIR


goodbye outdoor unit... With the hydraulic module, as a radiator substitute XF FE ETTO

A real advantage for on/off versions, both air or water-condensed, is the ability to connect Xfetto to a central heating system and use it as a radiator connected to the heating system circuit using the dedicated hydraulic module (optional), which also includes a three-way bypass valve. To use the radiator function Xfetto must be connected to the central heating system, whether it is centralised or autonomous. Suitable checks should first be carried out on the system to determine the water flow rate conditions in terms of volume and heat output. The connection can be made using the dedicated optional kit, which in concept represents a kind of interface module between xfetto and the central heating system. Without this kit, xfetto can still be installed with the maximum flexibility as an air conditioner/heat pump without an outdoor unit (for example in places where no central heating system is installed due to climatic conditions). The connection kit to the central heating system is symmetrical and can be fitted on the left or right of the device. It is designed to adapt to various different existing situations (pipes on the right, pipes on the left, delivery on the right and return on the left, delivery above and return below...). This means that the same kit can be used for both sides. The size and shape of the kit elegantly covers most types of hydraulic connection. The kit is comprised of a plastic casing and all the components (electronic and hydraulic) required for radiator operation. The installer need only make the hydraulic connections to the central heating system delivery and return pipes.

Installation with the hydraulic module for connection to a boiler

Radiator function!

46

www.argoclima.com


XF FE ETTO

DCI SPL/HPL

t SVPWM 180° full DC inverter technology t Heat pump with cool, heat, dehumidify and fan functions t Universal multifunction remote control with LCD display, Feel sensor, wall mount and transmitter with a wide range of operation t Temperature check comparison between remote control sensor and unit sensor t iFeel function t ECO and High Power functions t Horizontal deflector with 6 positions set via remote control and iFlap function for intelligent air distribution t Automatic fan speed and/or three set speeds available via remote control

t Condensing with variable speed fan t Intelligent Cold draft and Defrost functions t Additional electrical heating (820 watts) activated by the software in auto mode when the unit is unable to balance the thermal load, or manually activated/deactivated via remote control as a booster for the heat pump or as a Fan Heater t Auto-restart following black outs and excess pressure protection devices t High efficiency rotary compressor covered by a 5-year warranty t Optional feet for floor installation (windows, loft conversions...)

PRODUCT NAME Features Cooling capacity Additional electrical resistance Energy label class E.E.R. / C.O.P. Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure (h.-m.-l.) Power supply Runnig consumption Annual energy cons. - A/C (500h)-Dir. 2002/31/CE Refrigerant type Ducts diameter Condensate discharge Net weight Net dimension (H./W./D.)

Units kW kW ABCDEFG (kW/kW) m3/h litres/h n° dB(A) V/Ph/Hz kW kWh mm Kg mm

XFETTO DCI Cooling Heating 1,85 (1,10-2,93) 2,27 (0,90-3,05) 0,85 A A 3,17 2,61 330-300-280 1,0 3 + Auto 43-38-35 230/1/50 0,710 0,715 355 R410A 162 by duct, outside or inside the room 49 735x839x260-280

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

www.argoclima.com

47


Air condensed

XF FE ETTO

245C cooling only 235H heat pump t Installation on a perimeter wall t Automatic switching from cooling to heating action based on the set temperature (235H) t Radiator operation when connected to the heating system circuit using the dedicated hydraulic module (optional), which includes a three-way bypass valve t Remote control with digital 24h thermostat/timer and up to 4 addresses t Dual temperature sensor (on the unit and on the remote control) t iFeel & Night functions t Horizontal deflector that can be switched between fixed and oscillating positions via remote control t Condensing with variable speed outdoor fan for maximum quietness

PRODUCT NAME Features

t Tangential fan with three programmable speeds or automatic speed control t Device that prevents the release of cold air into the room by activating heat pump mode during defrosting cycles (235H) t Device that prevents the circulation of air in the room when the heating water temperature is below 40°C in radiator mode t Precision thermostat with settings from 6°C to 40°C in radiator mode t Auto restart following power black outs t Electronic protection against excess pressure t High efficiency rotary compressor covered by a 5-year warranty t Optional feet for floor installation (windows, loft conversions...)

Units kW BTU/h kcal/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh kW

Cooling/Heating capacity (A/Conditioner mode) Heating capacity (Water Radiator mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure in Air/Conditioner mode (h.-m.-l.) Sound pressure in Water radiator mode (h.-m.-l.) Power supply Running consumption in Air/Conditioner mode Annual energy cons.- A/C(500h)-Directive 2002/31/EC Running consumption in Water radiator mode Refrigerant type Ducts diameter Hydraulic connection diameter on the heating plant (W.R.mode) Condensate discharge Condensate drain connection diameter (outside) Net weight Net dimensions (H./W./D.)

mm inch mm Kg mm

XFETTO 245C Cooling 2,45 8.360 2.110 2,10 A 2,62 330-300-280 1,2 3 + Auto 45-43-41 42-39-32 230/1/50 0,935 468 0,027 R410A 162 1/2"

XFETTO 235H Cooling 2,35 8.020 2.020 2,10 A 2,61

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

48

www.argoclima.com

C 2,65 330-300-280 1,0 3 + Auto 45-43-41 42-39-32 230/1/50

0,900 450

0,850 0,027 R410A 162 1/2" gas F

not requested

by duct, outside or inside the room

50 735/839/260-280

18 52 735x839x260-280

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

Heating 2,25 7.700 1.935


XF FE ETTO

Water condensed

245SC H2O cooling only 235HP H2O heat pump

PRODUCT NAME Operation Features Cooling/Heating capacity (Air-Conditioner mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.-m.-l.) Dehumidification Fan speeds Sound pressure in Air-Conditioner mode (h.-m.-l.) Power supply Running consumption in Air-Conditioner mode Annual energy cons.- A/C(500h)-Directive 2002/31/EC Water flowrate for the heat exchanger Pressure drops Refrigerant type Water connection diameter (in/out) Condensate drain connection diameter (inside or outside) Heat transferred to water Heat moved from water Heating capacity in Water Radiator mode Running consumption in Water radiator mode Water flowrate in Water Radiator mode Pressure drops in Water Radiator mode Hydraulic connection diameter to the heating plant (W.R.mode) Sound pressure in Water radiator mode (h.-m.-l.) Net weight Net dimensions (H./W./D.)

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h litri/h n° dB(A) V/Ph/Hz kW kWh m³/h KPa inch mm kW kW kW kW m³/h kPa inch dB(A) Kg mm

t Dual temperature sensor (on the unit and on the remote control) t Dry, Fan Only, iFeel and Night Functions t Horizontal deflector that can be switched between fixed and oscillating positions via remote control t Washable air filters t Tangential fan with three programmable speeds or automatic speed control t Device that prevents the release of cold air into the room, in heat pump mode (235HP) t Device that prevents the circulation of air in the room when the heating water temperature is below 40°C in radiator mode t Precision thermostat with settings from 6°C to 40°C in radiator mode t Auto restart following power black outs t Electronic protection against excess pressure t High efficiency rotary compressor covered by a 5-year warranty t Optional feet for floor installation (windows, loft conversions...) XFETTO 245SCH2O Water loop(*) Town water Raffreddamento 2,83 2,7 9.650 9.200 2.430 2.320 B 4,42 4,15 330-300-280 1,2 1,2 3 + Auto 3 + Auto 44-42-41 44-42-41 230/1/50 0,640 0,650 325 0,150 0,525 2,9 38,0 R410A R410A 1/2" (gas) F 1/2" (gas) F 13/18 13/18 3,47 3,35 2,1 0,027 0,19 2,9 1/2" F 42-39-32 46 735/839/260-280

XFETTO 235HPH2O Water loop(*) Town water Raffr. Risc. Raffr. Risc. 2,95 3,15 3,00 3,56 10.060 10.740 10.230 12.140 2.540 2.710 2.580 3.060 A C 4,68 3,80 4,41 4,14 330-300-280 330-300-280 1,3 1,3 3 + Auto 3 + Auto 44-42-41 44-42-41 230/1/50 0,630 0,830 0,680 0,860 340 0,150 0,525 2,9 40,3 R410A R410A 1/2" (gas) F 1/2" (gas) F 13/18 13/18 3,58 3,68 2,04 2,7 2,1 0,027 0,19 2,9 1/2" (gas) F 42-39-32 48 735x839x260-280

water loop: standard conditions EN14511

t Can t Can be installed on any wall, even non-perimete non-perimeter er walls, walls because it does not require holes in the wall t Designed to work with mains water or a well/groundwater source, it can also operate as a terminal in a closed circuit water loop system with water at 30°C in accordance with EN14511 specifications t Very high levels of efficiency (EER up to 4.68) t Automatically switches from cooling to heating based on the set temperature (235HP) t Operates as a radiator when connected to the heating system circuit using the dedicated hydraulic module (optional), which includes a three-way bypass valve t High efficiency plate heat exchanger with a solenoid to cut off mains water circulation when the compressor is off t Antifreeze protection on condensation water circuit t Installation of a viewable filter on the mains water inlet (to be completed by installer) recommended t Remote control with digital 24h thermostat/timer and up to 4 addresses

Mains water - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 18°C - out 36°C / Heat pump: Amb. temp. 20 °C d.b. - Water temp. in 18°C - out 6°C Water loop - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 30°C - out 35°C / Heat pump: Amb. temp. 20°C d.b. - Water temp. 15°C Radiator - Amb. temp. 20°C - Water temp. in 70°C - out 60°C

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

www.argoclima.com

49


Notes:

XF FE ETTO 50

www.argoclima.com


X1 www.argoclima.com

51


Wall-mounted split unit air conditioner and heat pump

X1

t Wall-mounted split unit with heat pump t Elegant design in PMMA (high quality material) t Environmentally-friendly refrigerant R410A t Automatic switching between cooling and heating t Equipped with a multi-function remote control with digital timer, which allows operating cycles to be programmed over 24 hours t Tangential fan with three programmable speeds or automatic speed control t Remote-controlled horizontal deflector: with 5 set positions or automatic oscillation t Manually adjustable vertical deflector t Washable air filters t Activated carbon filters t BIO photocatalytic filter t Easily removable front panel secured by magnets t Automatic adaptation to night-time temperature variations function with 4 different programmes t Dehumidify only function t Turbo function for instant coolness/warmth t Automatic restart following power black outs t Electronic compressor protection t High efficiency rotary compressor

t Easy magnetic placement

PRODUCT NAME

X1 G 25

Indoor Unit

X1 G 25HL

X1 G 35HL

Outdoor Unit

X1 G 25SH

X1 G 35SH

Specifications

X1 G 35

Units

Cooling

Heating

Cooling

kW

2,7

2,85

3,5

Heating 3,8

BTU/h

9200

9720

12000

12960

Capacity Energy Class

ABCDEFG

A

A

A

A

E.E.R. / C.O.P.

(kW/kW)

3,21

3,61

3,21

3,61

Indoor unit air flow rate (h.m.l.)

m³/h

450-400-320

Dehumidification

l/h

0,8

1,2

Fan speed (Indoor / Outdoor)

3/1

3/1

Sound pressure Indoor (h.m.l.)

dB(A)

40-37-34

40-37-34

Sound pressure Outdoor (h.)

dB(A)

49

49

V/Ph/Hz

230/1/50

230/1/50

Power supply Power input

kW

0,84

0,79

1,09

1,05

Annual energy consumption (500h)

kWh

420

-

545

-

Compressor type

Rotary

Refrigerant type

R410A

Rotary R410A

Liquid pipe diameter

mm (inch")

6,35(1/4”)

6,35(1/4”)

Gas pipe diameter

12,7 (1/2”)

mm (inch")

9,52(3/8”)

Length of pipes (with standard charge)

m

7

7

Length of pipes (with additional charge)

m

10

10

Maximum height difference (outdoor unit above)

m

5

5

Maximum height difference (indoor unit above)

m

5

5

Net dimensions Indoor (H./W./D.)

mm

290x800x186

290x800x186

Net dimensions Outdoor (H./W./D.)

mm

480x600x250

540x700x255

Net weight Indoor/Outdoor

Kg

10/26

10/30

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

52

500-450-380

www.argoclima.com


Wall-mounted split unit air conditioner and heat pump – DC Inverter

X1

t Wall-mounted split unit with heat pump t DC Inverter technology for maximum comfort t Elegant design in PMMA (high quality material) t Environmentally-friendly refrigerant R410A t Automatic switching between cooling and heating t Equipped with a multi-function remote control with digital timer, which allows operating cycles to be programmed over 24 hours t Tangential fan with three programmable speeds or automatic speed control t Remote-controlled horizontal deflector: with 5 set positions or automatic oscillation t Manually adjustable vertical deflector t Washable air filters t Activated carbon filters t BIO photocatalytic filter t Easily removable front panel secured by magnets t Automatic adaptation to night-time temperature variations function with 4 different programmes t Dehumidify only function t Turbo function for instant coolness/warmth t Automatic restart following power black outs t Electronic compressor protection t High efficiency rotary compressor

t Easy magnetic placement

X1l G 25

PRODUCT NAME

X1l G 35

Indoor Unit

X1I G 25HL

X1I G 35HL

Outdoor Unit

X1I G 25SH

X1I G 35SH

Specifications

Units

Cooling

Heating

Cooling

Heating

kW

2,60 (1,45-4,0)

2,90 (1,4-5,0)

3,60 (1,84-4,10)

3,80 (1,50-5,10)

BTU/h

8.870 (4.950-13.650)

9.900 (4,8-17.100)

12.280 (6.280-14.000)

13.000 (5.120-17.400)

Capacity nominal (min-max) Energy Class E.E.R. / C.O.P. - nominal (min-max) Indoor unit air flow rate (h.m.l.)

ABCDEFG

A

A

A

A

(kW/kW)

3,42 (4,53-2,94)

3,67 (4,7-3,1)

3,43 (2,87-4,18)

3,62 (3,0-4,4)

m³/h

450-400-320

Dehumidification

l/h

0,8

1,2

Fan speed (Indoor / Outdoor)

3/1

3/1

Sound pressure Indoor (h.m.l.)

dB(A)

38-35-32

40-37-34

Sound pressure Outdoor (h.)

dB(A)

51

52

V/Ph/Hz

230/1/50

230/1/50

Power supply

500-450-380

Power input - nominal (min-max)

kW

0,76 (0,32-1,36)

0,8 (0,3-1,6)

1,050 (0,44-1,43)

1,05 (0,35-1,70)

Annual energy consumption (500h)

kWh

380

-

525

-

Compressor type

Rotary

Refrigerant type

R410A

Rotary R410A

Liquid pipe diameter

mm (inch")

6,35(1/4")

6,35(1/4")

Gas pipe diameter

12,7 (1/2")

mm (inch")

9,52(3/8")

Length of pipes (with standard charge)

m

7

7

Length of pipes (with additional charge)

m

10

10

Maximum height difference (outdoor unit above)

m

5

5

Maximum height difference (indoor unit above)

m

5

5

Net dimensions Indoor (H./W./D.)

mm

290x800x186

290x800x186

Net dimensions Outdoor (H./W./D.)

mm

540x700x255

540x700x255

Net weight Indoor/Outdoor

Kg

10/26

11/30

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

www.argoclima.com

53


Notes:

X1 54

www.argoclima.com


ON OFF Split and package on/off, heat pump and low ambient, up to 14 kW of thermal capacity for mono and multi applications, hi-wall, oor/ceiling or built-in (cassette) types.

www.argoclima.com

55


eco

R410A

OZONE FRIENDLY

Ulisse 13 PCL - 10 CLA Cooling only

ON OFF

t Floor console, cooling only t Only 24 cm depth, suitable for fixed or moveable floor installations t Small condensing case, specifically projected to be placed on balcony or window t Automatic condensate vaporization through the case t Infrared remote control with 24h digital timer and 4-addressing possibility, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor indoor the remote control t Double temperature sensor (on remote control / on indoor unit) t “I Feel” feature t Dry function t Three-speed fan by remote control

t Frontal air-intake, making possible its placement even between two walls t AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation t Adjustable air louver, granting the best fresh air diffusion t Washable air filters t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Accessories for the outside fixed installation of the case supplied with the unit t Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m)

PRODUCT NAME Features Capacity

ULISSE 10CLA

ULISSE 13PCLA

Units

Cooling

Cooling

kW

2,98

4,00

BTU/h

10.160

13.640 3.440

kcal/h

2.560

Energy label class

ABCDEFG

A

A

E.E.R. /C.O.P.

(kW/kW)

3,22

3,21 400-375-335

m K

370

Dehumidification

l/h

1,2

1,9

Fan speeds (Indoor / Outdoor)

3 + Auto / 1

3 + Auto / 1

Sound pressure Indoor (h.m.l.)

dB(A)

36-36-34

37-36-34

Sound pressure Outdoor (h.)

dB(A)

45

42

V/Ph/Hz

230/1/50

230/1/50

Running consumption

kW

0,925

1,25

Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE

kWh

463

625

R410A

R410A

Air flowrate (h./h.-m.-l.)

Power supply

Refrigerant type Standard pipe lenght

m

2

2

Additional pipe lenght

m

2-4

2-4

Max. height between units (Outdoor on the top)

m

1,2

1,2

Max. height between units (Indoor on the top)

m

5,2

5,2

Net weight Indoor / Outdoor

Kg

44/9,5

44/15

Net dimension Indoor (H./W./D.)

mm

790x580x245

790x580x245

Net dimension Outdoor (H./W./D.)

mm

435x440x230

490x525x250

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

56

www.argoclima.com


eco

R410A

OZONE FRIENDLY

Ulisse 10 HLA Heat pump

t Frontal air-intake, making possible its placement even between two walls t AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation t Adjustable air louver, granting the best fresh air diffusion t Washable air filters t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Accessories for the outside fixed installation of the case supplied with the unit t Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m)

PRODUCT NAME

ON OFF

t Floor console, cooling and heat pump t Only 24 cm depth, suitable for fixed or moveable floor installations t Small condensing case, specifically projected to be placed on balcony or window t Infrared remote control with 24h digital timer and 4-addressing possibility, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor indoor the remote control t Double temperature sensor (on remote control / on indoor unit) t “I Feel” feature t Dry function t Three-speed fan by remote control

ULISSE 10HLA

Features Capacity

Units

Cooling

kW

2,98

Heating 3,34

BTU/h

10.160

11.390 2.870

kcal/h

2.560

Energy label class

ABCDEFG

A

A

E.E.R. /C.O.P.

(kW/kW)

3,22

3,67

m K

Air flowrate (h./h.-m.-l.)

370

Dehumidification

l/h

1,2

Fan speeds (Indoor / Outdoor)

3 + Auto / 1

Sound pressure Indoor (h.m.l.)

dB(A)

35-31-29

Sound pressure Outdoor (h.)

dB(A)

39

V/Ph/Hz

230/1/50

Power supply Running consumption

kW

0,925

Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE

kWh

463

0,910 R410A

Refrigerant type Standard pipe lenght

m

2

Additional pipe lenght

m

2-4

Max. height between units (Outdoor on the top)

m

1,2

Max. height between units (Indoor on the top)

m

5,2

Net weight Indoor / Outdoor

Kg

44/15

Net dimension Indoor (H./W./D.)

mm

790x580x245

Net dimension Outdoor (H./W./D.)

mm

490x525x250

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

57


eco

R410A

AW 726/735 H

ifeel

Heat pump

ON OFF

t Automatic change-over between cooling and heating modes t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed tangential fan by remote control t Night set-back capability t Usable also without remote control t Horizontal flap by remote control: swinging or six fixed positions

PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

t Vertical flap with rear protection grille, allowing a safe installation of the indoor unit also at low distance from the floor (min. 1,7 mt) t Washable filters; active carbon filters (optional) t Double condensate discharge (right/left) to make easier the installation t Auto restart after a power supply black out t Electronic protection of the indoor units: anti-freeze; heating function disabled during defrosting cycle, electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

AW726H AW726HL/F AE726SH Cooling Heating 2,65 3,00 9.040 10.230 2.280 2.580 A A 3,44 3,80 450-400-370 1,2 3 + Auto/1 41-36-32 37 230/1/50 0,770 0,790 3,50 3,60 385 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 20 7 7 8/35 270x805x214 540x700x265

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

58

www.argoclima.com

AW735H AW735HL/F AE735SH Cooling Heating 3,4 3,7 11.600 12.620 2.920 3.180 A A 3,21 3,61 470-430-390 1,5 3 + Auto/1 41-36-32 40 230/1/50 1,025 1,060 5,40 5,20 530 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 8/35 270x805x214 540x700x265

3speed


eco

R410A

AW 752/764H/764H3

ifeel

3speed

Heat pump

PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

t Washable air filters; active carbon filters (optional) t Double condensate discharge (right/left) to make easier the installation t Auto restart after a power supply black out t Electronic protection of the indoor units: anti-freeze; heating function disabled during defrosting cycle, electronic protection against over-pressures t Anti-freeze protection of the outdoor unit t High efficiency rotary compressor t Self-diagnostic functions t Single-phase and three-phase (764H3) power supply

ON OFF

t Automatic change-over between cooling and heating modes t Available in single-phase and three-phase versions (764H3) t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed tangential fan by remote control t Night set back capability t Usable also without remote control t Horizontal flap by remote control: swinging or six fixed positions t Vertical flap with rear protection grille, allowing a safe installation of the indoor unit also at low distance from the floor (min. 1,7 mt)

AW752H AW752HL AE752SH Cooling Heating 5,00 5,80 17.100 19.780 4.300 4.990 A A 3,23 3,82 880-710-580 1,5 3 + Auto/1 46-43-38 43 230/1/50 1,55 1,52 7,00 6,70 775 Rotary R410A 6,35(1/4") 12,7(1/2") 10 20 20 15 15 12/57 285x995x240 630x830x305

AW764H AW764HL AE764SH Cooling Heating 6,60 7,80 22.500 26.600 5.676 6.710 A A 3,22 3,63 880-710-580 2,0 3 + Auto/1 49-43-38 47 230/1/50 2,05 2,15 9,20 9,50 1025 Rotary R410A 6,35(1/4") 15,88(5/8") 12,5 30 25 15 15 12/71 285x995x240 735x940x340

AW764H3 AW764HL AE764SH3 Cooling Heating 6,80 8,00 23.200 27.280 5.848 6.880 A A 3,24 3,64 880-710-580 2,0 3 + Auto/1 49-43-38 47 400/3N/50 2,10 2,20 4,10 4,30 1050 Rotary R410A 6,35(1/4") 15,88(5/8") 12,5 30 25 15 15 12/71 285x995x240 735x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

59


3speed

eco

OZONE FRIENDLY

R410A

AW 726/735 CL

ifeel

active carbon filter

ON OFF

t Able to operate with an outdoor air temperature up to -15°C t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed tangential fan by remote control t Night set-back capability t Usable also without remote control t Horizontal flap by remote control: swinging or six fixed positions t Vertical flap with rear protection grille, allowing safe installations

of the indoor unit even at any height from the floor (min. 1,7 m.) (EN60335 safety standard) t Washable filters; active carbon filters (optional) t Double condensate discharge (right/left) to make easier the installation t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions

Units kW ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

AW726CL AW726CL/F AE726SCL Cooling 2,70 A 3,51 450-400-370 0,8 3 + Auto/1 41-36-32 37 230/1/50 0,770 3,40 385 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 20 7 7 8/34 270x805x214 540x700x265

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

60

+43°C

-15°C

Cooling only

MATCHING Indoor unit Outdoor unit Features Cooling capacity Energy label class E.E.R. Air flowrate Indoor (h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.- cooling (500h) - Dir.2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

washable filters

www.argoclima.com

AW735CL AW735CL/F AE735SCL Cooling 3,40 A 3,24 470-430-390 1,5 3 + Auto/1 41-36-32 40 230/1/50 1,050 4,70 525 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 8/34 270x805x214 540x700x265


3speed

eco

OZONE FRIENDLY

R410A

AW 752 CL/CL3 -AW 764 CL3

ifeel

active carbon filter

washable filters

+43°C

-15°C

t Able to operate with an outdoor air temperature up to -15°C t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed tangential fan by remote control t Night set-back capability t Usable also without remote control t Horizontal flap by remote control: swinging or six fixed positions

t Vertical flap with rear protection grille, allowing safe installations of the indoor unit even at any height from the floor (min. 1,7 m.) (EN60335 safety standard) t Washable filters; active carbon filters (optional) t Double condensate discharge (right/left) to make easier the installation t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions t Single-phase and three-phase versions

www.argoclima.com

61

ON OFF

Cooling only


3speed

eco

OZONE FRIENDLY

R410A

FC 735/752 CL

ifeel

active carbon filter

washable filters

-15°C

Cooling only

ON OFF

t Able to operate with an outdoor air temperature up to -15°C t Single-phase (230V-1-50Hz) power supply t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed centrifugal fan by remote control t Night set-back capability

PRODUCT NAME Indoor unit Outdoor unit Features Cooling capacity Energy label class E.E.R. Air flowrate Indoor (h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

t Usable also without remote control t Horizontal flap swinging or to be set to on of the six possible fixed position by remote control t Vertical flap by manual control t Washable filters; active carbon filters (optional) t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions

Units kW ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

FC735CL FC735CL AE735SCL Cooling 3,40 A 3,24 670-550-450 1,5 3 + Auto/1 47-44-39 40 230/1/50 1,05 4,70 525 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 23,5/34 680x900x190 540x700x265

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

62

+43°C

www.argoclima.com

FC752CL FC752CL AE752SCL Cooling 5,00 A 3,23 715-610-510 1,8 3 + Auto/1 49-47-40 43 230/1/50 1,55 7,00 775 Rotary R410A 6,35(1/4") 12,7(1/2") 10 20 20 15 15 23,5/55 680x900x190 630x830x305


3speed

eco

OZONE FRIENDLY

R410A

FC 752/764 CL3

ifeel

active carbon filter

washable filters

+43°C

-15°C

t Able to operate with an outdoor air temperature up to -15°C t Three-phase (400-3N-50Hz) power supply t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed centrifugal fan by remote control t Night set-back capability

PRODUCT NAME Indoor unit Outdoor unit Features Cooling capacity Energy label class E.E.R. Air flowrate Indoor (h.-m.-l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.-cooling(500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

t Usable also without remote cotrol t Horizontal flap swinging or to be set to on of the six possible fixed position by remote control t Vertical flap by manual control t Washable filters; active carbon filters (optional) t Auto restart after a power supply black out t Electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions

Units kW ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

FC752CL3 FC752CL AE752SCL3 Cooling 5,00 A 3,23 715-610-510 1,8 3 + Auto/1 49-47-40 44 400/3N/50 1,55 3,20 775 Rotary R410A 6,35(1/4") 12,7(1/2") 10 20 20 15 15 23,5/55 680x900x190 630x830x305

FC764CL3 FC764CL AE764SCL3 Cooling 6,50 B 3,13 890-790-640 2,0 3 + Auto/1 51-49-46 47 400/3N/50 2,08 4,20 1040 Rotary R410A 6,35(1/4") 15,88(5/8") 12,5 30 25 15 15 23,5/71 680x900x190 735x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

63

ON OFF

Cooling only


3speed

eco

OZONE FRIENDLY

R410A

AS 71/100/125 CL3

ifeel

active carbon filter

washable filters

-15°C

Cooling only

ON OFF

t Able to run with an outdoor air temperature up to -15°C t Three-phase (400-3-50 Hz) power supply t Infrared remote control; 24h digital timer; 4-addressing possibility t Double temperature sensor (on the unit and indoor the remote control) t “I Feel” feature, granting the best comfort conditions t Dry function t Three-speed centrifugal fan by remote control t Special system to avoid condensate dripping from air outlet ribs t Night set-back capability

PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (l.-m.-h.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.-m.-l.) Sound pressure Outdoor (h.) Power supply Power input Running consumption Annual energy cons.- cooling (500h)-Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.)

Units kW ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW A kWh

mm(inch") mm(inch") m m m m Kg mm mm

t Usable also without remote cotrol t Four horizontal flap by remote control: swinging or six fixed positions t Washable filters t Integrated pump for condensate discharge t Auto restart after a power supply black-out t Electronic protection against over-pressures t High efficiency rotary compressor t Self-diagnostic functions

AS71CL3 AS71CL AE71SCL3 Cooling 7,80 B 3,02 680-840-1.020 3,0 3 + Auto/ 2-3 (Auto) 47-45-44 48 400/3N/50 2,58 5,10 1290 Rotary R410A 6,35(1/4") 15,88(5/8") 7,5 30 15 15 22/71 338x860x860 735x940x340

AS100CL3 AS100CL AE100SCL3 Cooling 10,40 A 3,21 1.320-1.680-1.920 3,5 3 + Auto/ 2-3 (Auto) 54-51-47 50 400/3N/50 3,30 6,60 1.650 Rotary R410A 9,52(3/8") 19,05(3/4") 7,5 40 25 25 27/104 368x1.150x860 1.235x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

64

www.argoclima.com

+43°C

AS125CL3 AS125CL AE125SCL3 Cooling 14,10 not under Energy labelling

2,82 1.320-1.680-1.920 5,0 3 + Auto/ 2-3 (Auto) 54-51-47 51 400/3N/50 5,00 9,70 not under Energy labelling

Scroll R410A 9,52(3/8") 19,05(3/4") 7,5 40 25 25 27/128 368x1.150x860 1.235x940x340


ON OFF

Notes:

www.argoclima.com

65


Notes:

ON OFF 66

www.argoclima.com


PACKAGE Package DC Inverter up to 14 kW of thermal capacity for single and multi applications, for high-wall, oor/ceiling or built-in type (cassette and ducted)

www.argoclima.com

67


eco

auto restart

R410A ifeel

AWS 71 PH/H3

t PAM DC Inverter technology t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function t New three-speed tangential fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set to a fixed position by remote control

PACKAGE

PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

3speed

+43°C

-15°C

t Vertical flap by manual control t Washable air filters t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single-phase (230/1/50) and Three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh

mm(inch") mm(inch") m m gr/m m m Kg mm mm

AWS71PH/H3/H3B AWS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,01 3,54 1.140-1.020-840 4,0 3 + Auto / 3 (Auto) 41-37-34 49 230/1/50-400/3/50 2,36 2,26 1.180 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 21/58 330x1.140x228 780x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

68

washable filters

www.argoclima.com


eco

auto restart

R410A ifeel

ASS 71/100 PH/H3

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

3speed

+43°C

-15°C

position by remote control t Washable filters t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic t Valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single-phase (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh

mm(inch") mm(inch") m m m m Kg mm mm

ASS71PH/H3/H3B ASS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 A A 3,33 3,86 1.140-1.020-840 3,6 3 + Auto / variable 47-45-41 47 49 230/1/50 - 400/3/50 2,13 2,07 1.065 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 28/58 338x860x860 780x940x340

ASS100PH/H3/H3B ASS100PH AES100PIH/H3/H3B Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 A A 3,21 3,78 1.920-1.680-1.320 4,6 3 + Auto / variable 53-50-46 51 52 230/1/50 - 400/3/50 3,12 2,96 1.560 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 35/65 338x1.150x860 780x940x340

PACKAGE

t PAM DC Inverter technology t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Special system to avoid condensate dripping from air outlet ribs t Four horizontal flaps swinging or to be set on a fixed

washable filters

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

69


eco

auto restart

R410A ifeel

ASS 125 PH/H3B

t PAM DC Inverter technology t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Special system to avoid condensate dripping from air outlet ribs

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features

PACKAGE

Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

3speed

+43°C

-15°C

t Four horizontal flaps swinging or to be set on a fixed position by remote control t Washable filters t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic t Valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single-phase (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³ / h l/ h n° dB ( A ) dB( A ) V / Ph / Hz kW kWh

mm(inch") mm(inch") m m m m Kg mm mm

ASS125PH/H3B ASS125PH AES125PIH/H3B Heating Cooling 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 2,81 3,32 1 . 9 2 0 -1 . 6 8 0 -1 . 3 2 0 6,3 3 + Auto / variable 53-50-46 52/51 53/54 230/1/50 / 400/3/50 3,86/4,45 3,83/4,22 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 35/ 100 3 3 8 x 1 .1 5 0 x 8 6 0 1.230x940x340 / 910x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

70

washable filters

www.argoclima.com


eco

auto restart

R410A ifeel

ADS 71 PH/H3

PAM DC Inverter technology Three-way duct connection Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

3speed

+43°C

-15°C

t Possibility to increase the Static Pressure t New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m K l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh

mm(inch") mm(inch") m m m m mm Kg mm mm

ADS71PH/H3/H3B ADS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 C C 2,83 3,35 1.080-900-780 3,5 5-10 3 + Auto / variable 43-39-36 34-30-27 20 47 49 230/1/50 - 400/3/50 2,51 2,39 1.255 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 200 32/58 310x1.000x630 780x940x340

PACKAGE

t t t t

integrated plenum

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

71


eco

auto restart

R410A ifeel

ADS 100 PH/H3

t t t t t

t t t

PAM DC Inverter technology Four-way duct connection Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function Possibility to increase the Static Pressure

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features

PACKAGE

Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

3speed

+43°C

-15°C

t Integrated pump for condensate discharge t New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m K l/h mm W.C. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh

mm(inch") mm(inch") m m m m mm Kg mm mm

ADS100PH/H3/H3B ADS100PH AES100PIH/H3/H3B Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 C C 2,82 3,39 1.800-1.560-1.260 4,2 5-10 3 + Auto / variable 47-42-40 38-33-31 20 51 52 230/1/50 3,55 3,30 1.775 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 200 47/65 310x1.480x630 780x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

72

integrated plenum

www.argoclima.com


eco

auto restart

R410A ifeel

ADS 125 PH/H3B

t

t t t

PAM DC Inverter technology Four-way duct connection Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function Possibility to increase the Static Pressure

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features

3speed

+43°C

-15°C

t Integrated pump for condensate discharge t New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

ADS125PH/H3B ADS125PH AES125PIH/H3B

Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3 /h l/ h mm W.C. n° dB(A) dB ( A ) dB(A) dB( A ) V / Ph / H z kW kWh

mm(inch") mm(inch") m m m m mm Kg mm mm

Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 2,87/2,43 3,26/2,81 1.980-1.560-1.320 6,6 5 -1 0 3 + Auto / variable 49-46-42 40-37-33 <20 53/54 52/51 230/1/50 / 400/3/50 4,29/4,85 4,36/5,14 2.180/2.570 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 200 47-100/76 3 1 0 x 1 .4 8 0 x 6 3 0 1.230x940x340 / 910x940x340

PACKAGE

t t t t

integrated plenum

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

73


eco

auto restart

R410A

ACS 71/100 PH/H3

t PAM DC Inverter technology t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function t Three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features Cooling/Heating capacity - nominal (min-max)

PACKAGE

Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply (1ph-3ph) Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.)

Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh

mm(inch") mm(inch") m m m m Kg mm mm

washable filters

3speed

+43°C

-15°C

t Horizontal flap swinging or to be set on a fixed position by remote control, with automatic positioning according to selected mode (cooling or heating) t Washable air filters t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single-phase (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

ACS71PH/H3/H3B ACS71PH AES71PIH/H3/H3B Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,02 3,56 1.098-900-840 3,0 3 + Auto / variable 38-36-33 47 49 230/1/50 - 400/3/50 2,35 2,25 1.175 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 25/58 210x1.180x680 780x940x340

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

74

ifeel

www.argoclima.com

ACS100PH/H3/H3B ACS100PH AES100PIH/H3/H3B Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 B A 3,04 3,67 1.650-1.380-1.200 3,9 3 + Auto / variable 41-38-35 51 52 230/1/50 - 400/3/50 3,29 3,67 1.645 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 30 15 33/65 210x1.595x680 780x940x340


eco

auto restart

R410A ifeel

ACS 125 PH/H3

t PAM DC Inverter technology t Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Among controls available for this kind of indoor unit (all optional): the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the best comfort conditions (“I Feel” feature); a special wired controller with configuration, diagnostic and weekly timer capabilities t Night set back capability t Dry function t Three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

washable filters

3speed

+43°C

-15°C

t Horizontal flap swinging or to be set on a fixed position by remote control, with automatic positioning according to selected mode (cooling or heating) t Washable air filters t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes t Single-phase (230/1/50) and three-phase (400/3/50) power supply t High efficiency Twin rotary compressor

ACS125PH/H3B ACS125PH AES125PIH/AES125PIH3B Units Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) kW Cooling/Heating capacity - nominal (min-max) BTU/h 42.500 48.000 10.750 12.040 kcal/h ABCDEFG Energy label class (kW/kW) E.E.R. / C.O.P. 3,03/2,36 3,44/3,15 m³ / h 1 . 8 0 0 -1 . 5 6 0 -1 . 3 2 0 Air flowrate Indoor (h.m.l.) Dehumidification l/ h 5,6 n° Fan speeds (Indoor / Outdoor) 3 + Auto / variable 43-40-37 dB ( A ) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) dB( A ) 52/51 53/54 230/1/50 / 400/3/50 Power supply (1ph-3ph) V / Ph / Hz Running consumption kW 4,12/5,29 4,07/4,45 2.060/2645 kW h Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type DCInverter Twin Rotary R410A Refrigerant type 9,52(3/8") Liquid pipe diameter mm(inch") Gas pipe diameter mm(inch") 15,88(5/8") m 30 Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge m 50 m 30 Max. height between units (Outdoor on top) m 15 Max. height between units (Indoor on top) Net weight Indoor / Outdoor Kg 33/ 100 mm 2 1 0 x 1 .5 9 5 x 6 8 0 Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) mm 1.230x940x340 / 910X940X340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

www.argoclima.com

PACKAGE

PRODUCT NAME Indoor unit Outdoor unit (1ph/3ph) Features

75


Multipackage DC Inverter

AES 71 PIH/H3(B) Cooling: 7,1 kW Heating: 8 kW

AES 100 PIH/H3(B) Cooling: 10 kW Heating: 11,2 kW

AES 125 PIH/H3

AES 125 PIH/H3B

Cooling: Heating:

Cooling: 12,5 kW Heating: 14 kW

12,5 kW 14 kW

Outdoor/Indoor units Matching AES71PIH/H3/H3B

OUTDOOR UNIT MODEL Cooling Indoor unit models

Type AWS71PH

1 unit Connectable Indoor units 2 units also mixed

High-wall

Indoor capacity (kW)

Heating Total capacity

Indoor capacity (kW)

B

C

D

kW

A

B

C

D

kW

7,10

-

-

-

7,1 (2,2-8,0)

8,00

-

-

-

8,0 (2,2-9,0)

-

-

-

7,1 (2,2-8,0)

8,00

-

-

-

8,0 (2,2-9,0)

7,1 (2,2-8,0)

8,00

7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0)

8,00 4,00 4,00

4,00 4,00

-

-

8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0)

ASS71PH

Cassette

7,10

ACS71PH

Underceiling

7,10

ADS71PH AWS36PH ASS36PH

Ducted High-wall Cassette

7,10 3,55 3,55

3,55 3,55

-

-

8,0 (2,2-9,0)

ADS36PH

Ducted

3,55

3,55

-

-

7,1 (2,2-8,0)

4,00

4,00

-

-

8,0 (2,2-9,0)

FC36PHG

Floor/Ceiling

3,55

3,55

-

-

7,1 (2,2-8,0)

4,00

4,00

-

-

8,0 (2,2-9,0)

AES100PIH/H3/H3B

OUTDOOR UNIT MODEL Cooling Indoor unit models

1 unit

Connectable Indoor units

2 units also mixed

PACKAGE

3 units also mixed

Type ASS100PH

Cassette

Indoor capacity (kW)

Heating Total capacity

Indoor capacity (kW)

B

C

D

kW

A

B

C

D

kW

10,00

-

-

-

10,0 (2,2-11,2)

11,20

-

-

-

11,2 (2,2-12,5) 11,2 (2,2-12,5)

ACS100PH

Underceiling

10,00

-

-

-

10,0 (2,2-11,2)

11,20

-

-

-

ADS100PH

Ducted

10,00

-

-

-

10,0 (2,2-11,2)

11,20

-

-

-

11,2 (2,2-12,5)

AWS56PH

High-wall

5,00

5,00

-

-

10,0 (2,2-11,2)

5,60

5,60

-

-

11,2 (2,2-12,5) 11,2 (2,2-12,5)

ASS56PH

Cassette

5,00

5,00

-

-

10,0 (2,2-11,2)

5,60

5,60

-

-

ADS56PH

Ducted

5,00

5,00

-

-

10,0 (2,2-11,2)

5,60

5,60

-

-

11,2 (2,2-12,5)

FC56PHG AWS36PH ASS36PH

Floor/Ceiling High-wall Cassette

5,00 3,55 3,55

5,00 3,55 3,55

3,55 3,55

-

10,0 (2,2-11,2) 10,65 10,65

5,60 4,00 4,00

5,60 4,00 4,00

4,00 4,00

-

11,2 (2,2-12,5) 12,0 12,0

ADS36PH

Ducted

3,55

3,55

3,55

-

10,65

4,00

4,00

4,00

-

12,0

FC36PHG

Floor/Ceiling

3,55

3,55

3,55

-

10,65

4,00

4,00

4,00

-

12,0

AES125PIH/H3/H3B Cooling

Indoor unit models

2 units also mixed Connectable Indoor units 3 units

4 units also mixed

76

Total capacity

A

OUTDOOR UNIT MODEL

1 unit

Total capacity

A

Type

Indoor capacity (kW)

Heating Total capacity

Indoor capacity (kW)

Cassette Underceiling

ADS125PH

Ducted

12,50

-

-

-

12,5 (2,7-14,0)

14,00

-

-

-

14,0 (2,7-16,0)

AWS71PH

High-wall

6,25

6,25

-

-

12,5 (2,7-14,0)

7,00

7,00

-

-

14,0 (2,7-16,0)

ASS125PH ACS125PH

B -

C -

D -

kW 12,5 (2,7-14,0) 12,5 (2,7-14,0)

A 14,00 14,00

B -

C -

Total capacity

A 12,50 12,50

D -

kW 14,0 (2,7-16,0) 14,0 (2,7-16,0)

ASS71PH

Cassette

6,25

6,25

-

-

12,5 (2,7-14,0)

7,00

7,00

-

-

14,0 (2,7-16,0)

ACS71PH

Underceiling

6,25

6,25

-

-

12,5 (2,7-14,0)

7,00

7,00

-

-

14,0 (2,7-16,0)

ADS71PH AWS45PH ASS45PH

Ducted High-wall Cassette

6,25 4,16 4,16

6,25 4,16 4,16

4,16 4,16

-

12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0)

7,00 4,66 4,66

7,00 4,66 4,66

4,66 4,66

-

14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0)

ADS45PH

Ducted

4,16

4,16

4,16

-

12,5 (2,7-14,0)

4,66

4,66

4,66

-

14,0 (2,7-16,0)

FC45PHG

Floor/Ceiling

4,16

4,16

4,16

-

12,5 (2,7-14,0)

4,66

4,66

4,66

-

14,0 (2,7-16,0)

AWS36PH

High-wall

3,12

3,12

3,12

3,12

12,5 (2,7-14,0)

3,50

3,50

3,50

3,50

14,0 (2,7-16,0)

ASS36PH

Cassette

3,12

3,12

3,12

3,12

12,5 (2,7-14,0)

3,50

3,50

3,50

3,50

14,0 (2,7-16,0)

ADS36PH

Ducted

3,12

3,12

3,12

3,12

12,5 (2,7-14,0)

3,50

3,50

3,50

3,50

14,0 (2,7-16,0)

FC36PHG

Floor/Ceiling

3,12

3,12

3,12

3,12

12,5 (2,7-14,0)

3,50

3,50

3,50

3,50

14,0 (2,7-16,0)

Note n.1

Indoor units names contain one number identifying their nominal capacity in kW (i.e.: 71=7,1kW=25000 BTU/h)

Note n.2

The Indoor units here indicated have the same caracteristics as the Indoor units used with the MultiSet DCInverter systems described in the following pages; the only difference is the type of pcb installed.

Note n.3

The control systems (wireless, wired, weekly timer, system controller, etc...) are equal to those used for the MultiSet DCInverter systems described in the following pages.

www.argoclima.com


Multipackage DCI features

t Straight cooling and heat pump Package DC Inverter R410A can be set with two, three or four indoor units operating simultaneously; this type of installation is the best for big shops, open space offices, restaurants,... t The installation of more indoor units in one only big room allows a better diffusion of the conditioned air

HIGH WALL INDOOR UNITS

t The MultiPackage DC Inverter R410A control systems allow a sophisticated control of single and multi-package configurations by zones, with a maximum of 256 indoor units being managed by one only intelligent controller t In addition to single-Package DC Inverter R410A features, change-over functionality and Cluster control, both in cooling and heating modes t Two-unit matchings (duo) are realized with a 2-way distribution joint kit t Three-unit matchings (trio) are realized with a 3-way distribution joint kit t Four-unit matchings (quartet) are realized with 3 distribution joint kits (2-way), in tree configuration (1 > 2 > 4)

CASSETTE INDOOR UNITS

t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t “I Feel” feature, granting the best comfort conditions t Night set back capability t All MultiPackage DC Inverter R410A systems may be controlled by infrared remote control with digital 24h timer and temperature sensor indoor or by a special wired controller with configuration, diagnostic and weekly timer capabilities; in the following pages are shown all the MultiPackage DC Inverter R410A control systems

DUCTED INDOOR UNITS

t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

PACKAGE

t Auto restart after a power supply black out t Electronic protection against over-pressures t Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes

CEILING INDOOR UNITS

t Single-phase (230/1/50) and Three-phase (400/3/50) power supply thanks to DC Inverter technology low consumption t Double rotary compressor

FLOOR/CEILING INDOOR UNITS

www.argoclima.com

77


Pipe lines

PIPES LENGHT AND DIFFERENCES BETWEEN UNITS IN DUO, TRIO AND QUARTET CONFIGURATIONS Description

Duo L+l1

Trio L+l1, L+l2

Quartet L+L1+l1, L+L1+l2

Tubing lenght from the Outdoor unit to the farthest Indoor unit

L+l2

L+l3

L+L2+l3, L+L2+l4

l1,l2

Tubing lenght after the first distribution

l1,l2,l3

l1>l2

15

L2+l3, L2+l4 Max: L2+l4 Min: L1+l1

l1-l2 l1-l3

l1-l2

50

L1+l1, L1+l2

l1>l2>l3

Difference between maximum and minimum tubing lenght , after the first distribution

Lenght (m)

10

(L2+l4)-(L1+l1)

l2-l3

Max. tubing lenght difference at distribution joint no. 1

-

-

L2>L1 L2-L1

10

Max. tubing lenght difference at distribution joint no. 2

-

-

l2>l1 l4>l3 l2-l1 l4-l3

10

PACKAGE

Max. height difference between units (Outdoor on top)

H1

30

Max. height difference between units (Indoor on top)

H1

15

Max. height difference between Indoor units

H2

H2, H3, H4

H2, H3, H4, H5, H6, H7

0,5

PIPES DIAMETER (I.U.) 36

45

56

71

100

125

Liquid pipe diameter

mm(inch")

6,35(1/4")

6,35(1/4")

6,35(1/4")

9,52(3/8")

9,52(3/8")

9,52(3/8")

Gas pipe diameter

mm(inch")

12,7(1/2")

12,7(1/2")

12,7(1/2")

15,88(5/8")

15,88(5/8")

15,88(5/8")

Type capacity of indoor units -->

78

www.argoclima.com


Indoor units table

AWS36PH AWS45PH AWS56PH AWS71PH

Air flowrate (h.m.l.) m3/h 720-600-420 m3/h 720-600-420 m3/h 780-660-480 m3/h 1140-1020-840

Hi-wall units Fan speeds Dry l/h 1,9 3 + Auto l/h 1,9 3 + Auto l/h 2,1 3 + Auto l/h 4,0 3 + Auto

Sound pressure(h.m.l.) dB(A) 35-31-27 dB(A) 35-31-27 dB(A) 38-34-30 dB(A) 41-37-34

Dimension (HxWxD) mm 285x995x203 mm 285x995x203 mm 285x995x203 mm 330x1.140x228

Net weight kg 12 kg 12 kg 12 kg 21

ASS36PH ASS45PH ASS56PH ASGM0918 (grille) ASS71PH (with grille) ASG0025E (grille) ASS100PH (with grille) ASS125PH (with grille) ASG3648E (grille)

m3/h 700-600-500 m3/h 750-630-530 m3/h 750-630-530 m3/h 1140-1020-840 m3/h 1920-1680-1320 m3/h 1920-1680-1320 -

Cassette units l/h 1,2 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,6 3 + Auto l/h 4,6 3 + Auto l/h 6,3 3 + Auto -

dB(A) 43-40-37 dB(A) 44-40-37 dB(A) 44-40-37 dB(A) 47-45-41 dB(A) 53-50-46 dB(A) 53-50-46 -

mm 273x575x575 mm 273x575x575 mm 273x575x575 mm 41x730x730 mm 338x860x860 mm 30x860x860 mm 338x1150x860 mm 338x1150x860 mm 30x1150x860

kg 16 kg 18 kg 18 kg 2,5 kg 22 kg 6 kg 27 kg 27 kg 8

ADS36PH 2-way duct (200 mm each) Plenum ADS45PH ADS56PH 3-way duct (200 mm each) Plenum ADS71PH ADS100PH ADS125PH

m3/h 600-510-440 m3/h 875-600-400 m3/h 875-600-400 m3/h 1080-900-780 m3/h 1800-1560-1260 m3/h 1980-1560-1320

Ducted units l/h 1,5 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,5 3 + Auto l/h 4,2 3 + Auto l/h 6,6 3 + Auto

dB(A) 45-43-40 dB(A) 45-38-33 dB(A) 45-38-33 dB(A) 34-30-27 dB(A) 38-33-31 dB(A) 40-37-33

mm 266x926x571 mm 266x926x200 mm 266x1132x571 mm 266x1132x571 mm 266x1132x200 mm 310x1000x630 mm 310x1480x630 mm 310x1480x630

kg 30 kg 6 kg 35 kg 35 kg 7,5 kg 32 kg 47 kg 47

FC36PHG FC45PHG FC56PHG

m3/h 700-590-500 m3/h 830-760-665 m3/h 830-760-665

Floor/ceiling units l/h 1,3 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto

dB(A) 47-43-38 dB(A) 52-49-46 dB(A) 52-49-46

mm 680x900x190 mm 680x900x190 mm 680x900x190

kg 23,5 kg 23,5 kg 23,5

ACS71PH ACS100PH ACS125PH

m3/h 1098-900-840 m3/h 1650-1380-1200 m3/h 1800-1560-1320

Ceiling units l/h 3,0 3 + Auto l/h 3,9 3 + Auto l/h 5,6 3 + Auto

dB(A)38-36-33 dB(A) 41-38-35 dB(A) 43-40-37

mm 210x1180x680 mm 210x1595x680 mm 210x1595x680

kg 25 kg 33 kg 35

PACKAGE

NB: For the indoor units capacity see the matching table.

www.argoclima.com

79


Controls & accessories

Infrared remote controller / i.u. HIGH-WALL Infrared remote controller to be used with high-wall indoor units

Infrared remote controller / i.u. AS-FC Infrared remote controller to be used with cassette and oor/ceiling indoor units

Infrared remote controller / i.u. AC Infrared remote controller to be used with underceiling indoor units

Infrared remote controller with receiver Infrared remote controller to be used, in matching with a special infrared receiver, with the full range of indoor units; it shows the operation status of the air-conditioner

Standard wired remote controller Standard wired remote controller with full features control, self-diagnostic and centralized programming capabilities

PACKAGE

SimpliďŹ ed wired remote controller SimpliďŹ ed wired remote controller to be used with the full range of indoor units; it controls all the main features

Remote sensor Remote sensor to be used with the full range of indoor units to detect the room temperature when no remote controller sensor or body sensor is used: suggested for air-conditioner systems without remote controller

Schedule timer Schedule timer able to manage up to 64 indoor units with customized programming of all features, on/off cycles, etc.

80

www.argoclima.com


Optional distribution joint kit

Capacity after distribution joint is 16.0 kW or less

DTVP

Capacity after distribution joint is 28.0 kW or less

PACKAGE

DDVI 16

www.argoclima.com

81


Notes:

PACKAGE 82

www.argoclima.com


www.argoclima.com

VRF VR F

Two/T Two/Three way modular systems for ins installations up to 135 kW/48HP max 3 outdoor units & 40 indoor units

83


Multiset V.R.F. DC Inverter Multiset DC Inverter systems demand the respect of precise rules in the engineering of a refrigerant circuit Argoclima gives to system engineers all support and accessories necessary for a correct implementation of an air conditioner system. t Engineering and design software t Distribution kits t Expansion valves with electronic control t Accessories to change the air with outside

Argoclima Multiset design support software

VRF

Our organization of Argo technicians and engineers is at Your disposal for the development of projects, the realization of CAD designs, the test/start of the system and the after-sale technical service. 84

www.argoclima.com


Multiset Vrf Systems Advantages FOR THOSE WHO DESIGN AND WHO PROPOSE CONSIDERABLE FLEXIBILITY OF THE TRACK: The high length of refrigerant pipes between indoor and outdoor units makes easier the installation adjustment to the configuration of the building; also the large distances between indoor and outdoor units allow to easily choose the best location for the condensing units. VERSATILE CONTROL SYSTEM: The control system allows numerous combinations of individual control, group control and system control. EASY MODIFICATIONS AND IMPLEMENTATIONS: If it was intended in the design phase, you can expand the system with the addition of indoor and outdoor units in a simple and practical way. FLEXIBILE MANAGEMENT: The system can have a power ratio between indoor and outdoor units from 50% to 130%.

FOR THOSE WHO PURCHASE AND WHO INSTALL COST REDUCTION The system uses only two pipes (three in case of systems with heat recovery): the cost and installation time are thus reduced. EASY INSTALLATION OF CONTROL SYSTEM: The control system uses a transmission circuit formed by two wires without polarity; in this way, you avoid errors and significantly reduces the time required for the connection. MINIMAL INVASIVENESS IN THE BUILDING: Pipes small sizes don’t allow to excessively pollute the building in which the system will be installed. This advantage is particularly important in case of structures already existing or under renovation. INSTALLATION TIME REDUCTION: The accessories for connecting pipes and the modular type of mounting facilitate and accelerate the time required for installation.

FOR THOSE WHO USE AND WHO MAKE MAINTENANCE CUSTOMIZED SELECTION: The user can select at will the environmental conditions of each area or room to obtain an optimal climate. A COMFORTABLE ENVIRONMENT: The temperature control reduces the time necessary to achieve the desired conditions, keeping them steadily. EASY USE OF THE REMOTE CONTROL: Remote Control allows you to obtain very easily maximum performances from each indoor unit. You can easily select the operation mode (dry/cooling/heating/ ventilation), the desired temperature, the air flow volume and direction, etc. HIGH PERFORMANCE ROTARY COMPRESSORS: The advanced design of the compressors together with the LONG-LIFE system, using cyclic compressors in multiple installations, offer extended service life.

www.argoclima.com

VRF VR F

SELF-DIAGNOSIS FUNCTION: In case of failure, both the remote devices and the outdoor units provide the information necessary to become aware of the location and characteristics of the failure, reducing repair and maintenance time.

85


Mini Multiset V.R.F. DC

AES04MMIH/H3 AES05MMIH/H3 AES06MMIH/H3

The Mini Multiset V.R.F. DC Inverter System is the new frontier of technology, specifically thought for residential and light commercial applications DCI High efficiency DC Inverter Compressor, circuit DCI PAM (Dc Inverter Pulse Amplitude modulation), maximum of 9 indoor units connectable to 1 outdoor unit (model AES06MMIH). DC Inverter Fan V.R.F. Variable Refrigerant Flow: continuous regulation of the refrigerant flow rate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (E.E.R. up to 4,06 - model AES04MMIH) R410A The most ecological and efficient refrigerant available for air conditioning systems of this level of thermal capacity COMPACT Reduced dimensions of the outdoor unit WIDE RANGE Three sizes available: 4-5-6 HP 230/400 VOLT Single-phase (230/1/50) and Three-phase (400/3/50) power supply

11,2 kW 12,5 kW 14 kW 16 kW 15,5 kW 17,6 kW

150 m Refrigerant circuit of a maximum length of 150 m, to be realized with a big save of time thanks to the reduced pipe dimension and to the simple tree structure that makes widening easy, not requiring any installation of expensive concentrator apparatus LAN (Local Area Network) For the interconnection of all the indoor/outdoor units and the system controls, realized with two wiring cables without polarization; the intelligent controllers are able to auto set all the units, simplifying and reducing to minimum the time-to-start SILENCE Low sound levels thanks to the special fans and to the careful study of the air movements in suction WIDE LIMITS The wide range of outdoor air temperature supported allows the operation even in extreme conditions: from -10°C to +43°C in cooling mode from -20°C to +15°C in heating mode MATCHIN & CONTROLS Indoor units, controllers (all optional) and accessories are the same as those of 2 and 3 way Multiset V.R.F.DCI

VRF 86

Cooling: Heating: Cooling: Heating: Cooling: Heating:

www.argoclima.com


Mini Multiset V.R.F. DC

Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. number of connectable indoor units Max. pipe lenght Gas standard charge Max. distance between indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.)

units HP kW BTU/h kcal/h (kW/kW) m続/h dB(A) V/Ph/Hz kW

mm(inch") mm(inch") no. m Kg m m m Kg mm

AES04MMIH/H3 Cooling Heating 4 11,2 12,5 38.200 42.700 9.630 10.750 4,06 4,34 6.000 51/48 230/1/50 - 400/3/50 2,76 2,88 DC Inverter R410A 9,52(3/8") 15,88(5/8") 6 150 3,5 15 50 40 104 1.200x940x340

AES05MMIH/H3 Cooling Heating 5 14,0 16,0 47.800 54.600 12.040 13.760 3,66 4,1 6.000 51/48 230/1/50 - 400/3/50 3,83 3,90 DC Inverter R410A 9,52(3/8") 15,88(5/8") 8 150 3,5 15 50 40 104 1.200x940x340

www.argoclima.com

AES06MMIH/H3 Cooling Heating 6 15,5 17,6 52.900 60.000 13.330 15.140 3,39 3,84 6.000 52/49 230/1/50 - 400/3/50 4,57 4,58 DC Inverter R410A 9,52(3/8") 19,05 (3/4") 9 150 3,5 15 50 40 104 1.200x940x341

VRF VR F

INVERTER outdoor units Features

87


Multiset V.R.F. DC DCI + SAC DC Inverter Compressor + Scroll AC Compressor, the perfect matching for a high efficiency system with capacity up to 48HP, automatically modulated by the DCI PAM (Dc Inverter Pulse Amplitude modulation) circuit on a maximum of 40 indoor units connected. V.R.F. Variable Refrigerant Flow: continuous regulation of the refrigerant flow rate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (COP up to 4,09). R410A The most ecological and efficient refrigerant available for air conditioning systems of this level of thermal capacity. TWO WAY Two-way system with possibility of condensing and indoor units increase thanks to the simple tree refrigerant circuit. THREE WAY New three-way solution with heat recovery, giving the possibility of a simultaneous independent operation in cooling and/or heating modes of each indoor unit. HFC= -21% Reduction of the total refrigerant volume of about 21% in comparison with the previous systems. 300 m Refrigerant circuit of a maximum length of 300 m, to be realized with a big save of time thanks to the reduced pipe dimension and to the simple tree structure that makes widening easy, not requiring any installation of expensive concentrator apparatus. LAN (Local Area Network) for the interconnection of all the indoor/ outdoor units and the system controls, realized with two wiring cables without polarization; the intelligent controllers are able to auto set all the units, simplifying and reducing to minimum the time-to-start. LONG LIFE A special electronic system controls the operating cycles of the compressors, distributing the load and extending the efficiency in the time. BACK UP The system is able to activate the automatic back-up of the condensing units in error or stopped; the sophisticated control system compensates the bad operation of the blocked outdoor unit, distributing the thermal power to the other outdoor units of the multiple configuration system. SILENCE For the first time the sound levels are lower than 52 dB; thanks to the special fans and to the careful study of the air movements in suction, the sound levels have been reduced of more than 4 dB in comparison with the previous models. WIDE RANGE The wide range of outdoor air temperature supported allows the operation even in extreme conditions: from -10°C to +43°C in cooling mode from -20°C to +15°C in heating mode FREE PLACE The condensing units in multiple configuration can be installed at a distance of only 10 cm or very far one from the other, even on different stages of the building; this feature makes the system more adaptable to the various circumstances.

VRF 88

www.argoclima.com


Outdoor Units 2-Way Systems Main features: - compactness, making units easier to position; - smaller pipe works, making material costs lower; - flexibility of installation; - high efficiency (C.O.P. at the top of the range: 3,90 average cooling/heating for the 8HP units) - reduced life cycle costs; - accurate capacity control; - possibility to choose among a wide range of control options.

VRF VR F

t Maximum number of Outdoor units connectable: 3. t Maximum total power of the system: 135 kW (48 HP). t Maximum number of Indoor units connectable: 40. t Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies. t R410A HFC refrigerant. t Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation up to 16 steps in spite of the usual 4 steps of the alternate current motors; this performance increases the efficiency of the thermodynamic system which is able to best adapt to the variations of temperature and thermal load of the rooms. t The use of a special oil sensor allows, for the first time in the world, to keep under control the lubrification of the mechanical parts of the compressor. t Special air intakes and Double Chamber construction technology allowed to unify the dimensions of the units, making easier the closing up for multiple installations in which two units can be placed at a distance of only 10 cm one from the other, the smaller distance available. t Low sound level thanks to a special fan made of resin and a particular resin grille, designed and used for these units in order to minimize air pressure drops. t New high efficiency Cross-Arranged heat exchanger with three-way suction, divided in two sections with double control of defrosting cycle. t Pressure control automatic and by software on PC. t Pipe connection indoor the unit frame through a special space to be closed back when the installation is finished. t Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case of total stop of one condensing unit. t Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance of the compressors activity. t Wide range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode. t Maximum length of the refrigerant circuit extended to 300 m. t The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units. t Three-phase auto sense power supply 380-415/3N/50Hz.

www.argoclima.com

89


Technical data 2-way INVERTER OUTDOOR UNIT Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Running consumption (cooling/heating) Running current Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Balance pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) mÂł/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° m m Kg mm

2-way INVERTER OUTDOOR UNIT Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Running consumption (cooling/heating) Running current Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Balance pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) mÂł/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° m m Kg mm

AES08MI2HA

AES10MI2HA

AES12MI2HA

22,40 / 25,00 3,74 / 4,05 9.000 54,5 / 51,5 65,5 400/3N/50 5,99 / 6,17 9,20 / 9,50 Twin Rotary DCI (N°1) R410A 9,52(3/8") 19,05(3/4") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 13 50 40 245 1.887x890(+60)x890

28,00 / 31,50 3,54 / 4,06 9.600 55 / 52 66,5 400/3N/50 7,90 / 7,75 12,30 / 12,00 Twin Rotary DCI+Scroll(N°2) R410A 9,52(3/8") 22,22(7/8") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 16 50 40 295 1.887x890(+60)x890

33,50 / 37,50 3,50 / 3,91 10.800 56 / 53 67,5 400/3N/50 9,58 / 9,60 14,90 /14,90 Twin Rotary DCI+Scroll(N°2) R410A 12,70(1/2") 25,40(1") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 19 50 40 295 1.887x890(+60)x890

AES14MI2HA

AES16MI2HA

40,00 / 45,00 3,45 / 3,91 12.000 61 / 58 71,5 400/3N/50 11,60 / 11,50 18,60 /18,50 Twin Rotary DCI+Scroll(N°3) R410A 12,70(1/2") 25,40(1") 6,35(1/4") 300 13 -10 a a 50 - 130 23 50 40 345 1.887x890(+60)x890

45,00 / 50,00 3,38 / 3,79 13.200 62 / 59 72 400/3N/50 13,30 / 13,20 21,30 /21,20 Twin Rotary DCI+Scroll(N°3) R410A 12,70(1/2") 28,58(1-1/8") 6,35(1/4") 300 13 -10 a a 50 - 130 26 50 40 345 1.887x890(+60)x890

VRF 90

www.argoclima.com


CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

18 HP AES10+AES08 MI2HA

20 HP AES10+AES10 MI2HA

22 HP AES12+AES10 MI2HA

50,40 / 56,50 3,63 / 4,06 9.600 + 9.000 58 / 55 69 400/3N/50 13,9 / 13,9 21,60 / 21,60 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 6,35(1/4") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 29 295 + 245 1.887x1.880x890(+60)

56,00 / 63,00 3,54 / 3,80 9.600 x 2 58 / 55 69,5 400/3N/50 15,8 / 15,5 24,7 / 24,2 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 6,35(1/4") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 33 295 x 2 1.887x1.880x890(+60)

61,50 / 69,00 3,51 / 3,97 10.800 + 9.600 58,5 / 55,5 69,5 400/3N/50 17,5 / 17,4 27,2 / 27,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 6,35(1/4") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 36 295 x 2 1.887x1.880x890(+60)

24 HP AES14+AES10 MI2HA

26 HP AES16+AES10 MI2HA

28 HP AES16+AES12 MI2HA

68,00 / 76,50 3,49 / 3,96 12.000 + 9.600 62 / 59 72,5 400/3N/50 19,5 / 19,3 30,8 / 30,4 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 6,35(1/4") 300 13,0 + 12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 1.887x1.880x890(+60)

73,00 / 81,50 3,44 / 3,88 13.200 + 9.600 63 / 60 73 400/3N/50 21,2 / 21,0 33,6 / 33,3 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 31,75(1-1/4") 6,35(1/4") 300 13,0 + 12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 1.887x1.880x890(+60)

78,50 / 87,50 3,43 / 3,84 13.200 + 10.800 63 / 60 73,5 400/3N/50 22,9 / 22,8 36,3 / 36,2 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 31,75(1-1/4") 6,35(1/4") 300 13,0 + 12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 1.887x1.880x890(+60)

30 HP AES16+AES14 MI2HA

32 HP AES16+AES16 MI2HA

34 HP AES 14+10+10 MI2HA

85,00 / 95,00 3,41 / 3,85 13.200 + 12.000 64,5 / 61,5 74,5 400/3N/50 24,9 / 24,7 39,9 / 39,6 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 31,75(1-1/4") 6,35(1/4") 300 13,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 2 1.887x1.880x890(+60)

90,00 / 100,00 3,38 / 3,79 13.200 x 2 65 / 62 75 400/3N/50 26,6 / 26,4 42,7 / 42,3 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 31,75(1-1/4") 6,35(1/4") 300 13,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 2 1.887x1.880x890(+60)

96,00 / 108,00 3,50 / 4,00 12.000 + 9.600 x 2 63 / 60 73,5 400/3N/50 27,4 / 27,0 43,1 / 42,5 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 31,75(1-1/4") 6,35(1/4") 300 13,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 x 2 1.887x2.870x890(+60)

www.argoclima.com

VRF VR F

Outdoor units matchings - technical data

91


Outdoor units matchings - technical data CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings

VRF

Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

92

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

36 HP AES 16+10+10 MI2HA

38 HP AES 16+12+10 MI2HA

40 HP AES 16+14+10 MI2HA

101,00 / 113,00 3,47 / 3,94 13.200 + 9.600 x 2 63,5 / 60,5 74 400/3N/50 29,1 / 28,7 45,8 / 45,2 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 x 2 1.887x2.870x890(+60)

107,00 / 119,00 3,47 / 3,68 13.200 +10.800 + 9.600 63,5 / 60,5 74,5 400/3N/50 30,8 / 30,6 48,0 / 48,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50-130 40 345 + 295 x 2 1.887x2.870x890(+60)

113,00 / 127,00 3,45 / 3,91 13.200 +12.000 + 9.600 65 / 62 75 400/3N/50 32,8 / 32,5 52,0 / 52,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 2 + 295 1.887x2.870x890(+60)

42 HP AES 16+16+10 MI2HA

44 HP AES 16+16+12 MI2HA

118,00 / 132,00 3,42 / 3,86 13.200 x 2 + 9.600 65,5 / 62,5 75,5 400/3N/50 34,5 / 34,2 55,0 / 54,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 2 + 295 1.887x2.870x890(+60)

124,00 / 138,00 3,43 / 3,83 13.200 x2 + 10.800 65,5 / 62,5 76 400/3N/50 36,2 / 36,0 57,0 / 57,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 2 + 295 1.887x2.870x890(+60)

46 HP AES 16+16+14 MI2HA

48 HP AES 16+16+16 MI2HA

130,00 / 145,00 3,40 / 3,83 13.200 x 2 + 12.000 66,5 / 63,5 76,5 400/3N/50 38,2 / 37,9 61,0 / 61,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0 x 3 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 3 1.887x2.870x890(+60)

135,00 / 150,00 3,38 / 3,79 13.200 x 3 67,0 / 64,0 77 400/3N/50 39,9 / 39,6 64,0 / 64,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 38,10(1-1/2") 6,35(1/4") 300 13,0 x 3 -10 ~ +43 / -20 ~ +15 50-130 40 345 x 3 1.887x2.870x890(+60)

www.argoclima.com


Outdoor Units 3-Way Systems

Main features:

VRF VR F

t Automatic change-over between cooling and heating modes for each indoor unit; this feature, based on the three-way technology with heat recovery, allows a fully independent operation of each indoor unit. t R410A HFC refrigerant. t Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies, matching with a Scroll Constant-Speed compressor . t Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation up to 16 steps in spite of the usual 4 steps of the alternate current motors; this performance increases the efficiency of the thermodynamic system which is able to best adapt to the variations of temperature and thermal load of the rooms . t The use of a special oil sensor allows, for the first time in the world,to keep under control the lubrification of the mechanical parts of the compressor. t Special air intakes and Double Chamber construction technology allowed to unify the dimensions of the units, making easy the closing up for multiple installations in which two units can be placed at a distance of only 10 cm one from the other, the smaller distance available. t Low sound level thanks to a special fan made of resin and a particular resin grille, designed and used for these units in order to minimize air pressure drops. t New high efficiency Cross-Arranged heat exchanger with three-way suction, divided in two sections with double control of defrosting cycle. t Pressure control automatic and by software on PC. t Pipe connection indoor the unit frame through a special space to be closed back when the installation is finished. t Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case of total stop of one condensing unit. t Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance of the compressors activity. t “On Demand” feature allows to best use the characteristics of DC Inverter technology, setting three different levels of electric power on which are automatically based the control microprocessors so that to achieve the maximum performances with reduction of electric consumption. t Extra range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode. t Maximum length of the refrigerant circuit extended to 300 m. t The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units. t Three-phase auto sense power supply 380-415/3N/50Hz.

www.argoclima.com

93


Technical data

3-way INVERTER OUTDOOR UNITS Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Gas pipe diameter (discharge) Balance pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % no. m m Kg mm

3-way INVERTER OUTDOOR UNITS Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Gas pipe diameter (discharge) Balance pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % no. m m Kg mm

AES08MI3H

AES10MI3H

AES12MI3H

22,40 / 25,00 3,78 / 4,09 9.000 54,5/51,5 65,5 400/3N/50 5,93 / 6,11 9,20 / 9,50 Twin Rotary DCInv.+ Scroll CS R410A 9,52(3/8") 19,05(3/4") 15,88(5/8") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 13 50 40 290 1.887x890x890(+60)

28,00 / 31,50 3,45 / 3,95 9.600 55/52 66 400/3N/50 8,12 / 7,97 12,30 / 12,0 Twin Rotary DCInv.+ Scroll CS R410A 9,52(3/8") 22,22(7/8") 19,05(3/4") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 16 50 40 290 1.887x890x890(+60)

33,50 / 37,50 3,41 / 3,81 10.800 56/53 67 400/3N/50 9,82 / 9,84 14,9 / 14,9 Twin Rotary DCInv.+ Scroll CS R410A 12,70(1/2") 25,40(1") 19,05(3/4") 6,35(1/4") 300 12 -10 ~ +43 / -20 ~ +15 50 - 130 19 50 40 290 1.887x890x890(+60)

AES14MI3H

AES16MI3H

40,00 / 45,00 3,45 / 3,91 12.000 60/57 71 400/3N/50 11,6 /11,5 19,0 / 18,9 Twin Rotary DCInv.+ Scroll CS R410A 12,70(1/2") 25,40(1") 22,22(7/8") 6,35(1/4") 300 15 -10 ~ +43 / -20 ~ +15 50 - 130 23 50 40 350 1.887x890x890(+60)

45,00 /50,00 3,38 / 3,79 13.200 61/58 72 400/3N/50 13,3 /13,2 21,8 / 21,6 Twin Rotary DCInv.+ Scroll CS R410A 12,70(1/2") 28,58(1-1/8") 22,22(7/8") 6,35(1/4") 300 15 -10 ~ +43 / -20 ~ +15 50 - 130 26 50 40 350 1.887x890x890(+60)

VRF 94

www.argoclima.com


Outdoor units matchings - technical data

Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Discharge pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Discharge pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

18 HP AES 10+08 MI3H

20 HP AES 10+10 MI3H

22 HP AES 12+10 MI3H

24 HP AES 14+10 MI3H

50,40 / 56,50 3,57 / 4,01 9.600 + 9.000 58 / 55 69 400/3N/50 14,1 / 14,1 22,6 / 22,6 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 22,22((7/8") 9,52(3/8") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 29 295 + 245 1.887x1.880x890(+60)

56,00 / 63,00 3,46 / 3,96 9.600 x 2 58 / 55 69 400/3N/50 16,2 / 15,9 26,0 / 25,5 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 22,22((7/8") 9,52(3/8") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 33 295 x 2 1.887x1.880x890(+60)

61,50 / 69,00 3,44 / 3,88 10.800 + 9.600 58,5 / 55,5 69,5 400/3N/50 17,9 / 17,8 28,7 / 28,5 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 25,4(1") 9,52(3/8") 300 12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 36 295 x 2 1.887x1.880x890(+60)

68,00 / 76,50 3,45 / 3,92 12.000 + 9.600 58 / 55 72,5 400/3N/50 19,7 / 19,5 31,9 / 31,6 Twin Rotary+Scroll Electr. Exp. Valve R410A 15,88(5/8") 28,58(1-1/8") 25,4(1") 9,52(3/8") 300 13,0 + 12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 345 + 295 1.887x1.880x890(+60)

26 HP AES 16+10 MI3H

28 HP AES 16+12 MI3H

30 HP AES 16+14 MI3H

32 HP AES 16+16 MI3H

73,00 / 81,50 3,41 / 3,84 13.200 + 9.600 60 / 57 73 400/3N/50 21,4 / 21,2 34,7 / 34,4 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 28,58(1-1/8") 25,4(1") 9,52(3/8") 300 15,0 + 12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 640 1.887x1.880x890(+60)

78,50 / 87,50 3,40 / 3,80 13.200 + 10.800 60,5 / 57,5 73,5 400/3N/50 23,1 / 23,0 37,5 / 37,3 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-3/8" 28,58(1-1/8") 9,52(3/8") 300 15,0 + 12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 640 1.887x1.880x890(+60)

85,00 / 95,00 3,41 / 3,85 13.200 + 12.000 61 / 58 74,5 400/3N/50 24,9 / 24,7 40,8 / 40,5 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-3/8" 28,58(1-1/8") 9,52(3/8") 300 13,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 40 700 1.887x1.880x890(+60)

90,00 / 100,00 3,38 / 3,79 13.200 x 2 61,5 / 58,5 75 400/3N/50 26,6 / 26,4 43,6 / 43,3 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-3/8" 28,58(1-1/8") 9,52(3/8") 300 15,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 40 700 1.887x1.880x890(+60)

VRF VR F

CAPACITY CLASSES (HP) Outdoor units matchings

www.argoclima.com

95


Outdoor units matchings - technical data

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Discharge pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

CAPACITY CLASSES (HP) Outdoor units matchings Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Sound power (normal mode) Power supply Power input (cooling/heating) Running current (cooling/heating) Compressor type Refrigerant control Refrigerant type Liquid pipe diameter after 1° distributor kit Gas pipe diameter after 1° distributor kit Discharge pipe diameter after 1° distributor kit Diameter of balancing pipe Max. pipe lenght Gas standard charge Operating limits (cooling/heating) Capacity ratio of indoor unit to outdoor unit Connectable indoor units Net weight Outdoor Net dimension Outdoor (H./W./D.)

Units kW (kW/kW) m³/h dB(A) dB(A) V/Ph/Hz kW A

mm(inch") mm(inch") mm(inch") mm(inch") m Kg °C % N° Kg mm

34 HP AES 14+10+10 MI3H

36 HP AES 16+10+10 MI3H

38 HP AES 16+12+10 MI3H

40 HP AES 14+14+10 MI3H

96,00 / 108,00 3,45 / 3,93 12.000 + 9.600 x 2 61 / 58 73,5 400/3N/50 27,8 / 27,5 45,1 / 44,6 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-3/8" 28,58(1-1/8") 9,52(3/8") 300 15,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 40 930 1.887x2.870x890(+60)

101,00 / 113,00 3,41 / 3,88 13.200 + 9.600 x 2 61,5 / 58,5 74 400/3N/50 29,1 / 28,7 48,0 / 47,2 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 28,58(1-1/8") 9,52(3/8") 300 15,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 40 930 1.887x2.870x890(+60)

107,00 / 119,00 3,42 / 3,84 13.200 +10.800 + 9.600 61,5 / 58,5 74 400/3N/50 31,3 / 31,0 51,0 / 50,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0+12,0 x 2 -10 ~ +43 / -20 ~ +15 50 - 130 40 930 1.887x2.870x890(+60)

113,00 / 127,00 3,42 / 3,88 13.200 +12.000 + 9.600 62 / 59 75,5 400/3N/50 33,0 / 32,7 54,0 / 54,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 990 1.887x2.870x890(+60)

42 HP AES 16+16+10 MI3H

44 HP AES 16+16+12 MI3H

46 HP AES 16+16+14 MI3H

48 HP AES 16+16+16 MI3H

118,00 / 132,00 3,40 / 3,84 13.200 x 2 + 9.600 62,5 / 59,5 75,5 400/3N/50 34,7 / 34,4 57,0 / 56,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 990 1.887x2.870x890(+60)

124,00 / 138,00 3,41 / 3,81 13.200 x2 + 10.800 62,5 / 59,5 76 400/3N/50 36,4 / 36,2 60,0 / 59,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0 x 2+12,0 -10 ~ +43 / -20 ~ +15 50 - 130 40 990 1.887x2.870x890(+60)

130,00 / 145,00 3,40 / 3,83 13.200 x 2 + 12.000 63 / 60 76,5 400/3N/50 38,2 / 37,9 63,0 / 62, 0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0 x 3 -10 ~ +43 / -20 ~ +15 50 - 130 40 1050 1.887x2.870x890(+60)

135,00 / 150,00 3,38 / 3,79 13.200 x 3 63 / 60 77 400/3N/50 39,9 / 39,6 65,0 / 65,0 Twin Rotary+Scroll Electr. Exp. Valve R410A 19,05(3/4") 1-5/8" 1-3/8" 9,52(3/8") 300 15,0 x 3 -10 ~ +43 / -20 ~ +15 50 - 130 40 1050 1.887x2.870x890(+60)

VRF 96

www.argoclima.com


VRF VR F

Control Systems / Dimensions

www.argoclima.com

97


Mini Multiset V.R.F. DC Position

part A

part B

part C

part D

part E

part F

part G

part H

part I

Dimension

Liquid pipe

Gas pipe

insulator

insulator

Gas pipe

Gas pipe

insulator

insulator

Liquid pipe

Liquid pipe

insulator

insulator

Gas pipe

Liquid pipe

insulator

insulator

Liquid pipe

Gas pipe

insulator insulator

VRF 98

www.argoclima.com

part J


Solenoid valve kits for 3 - way sy

M3 EVV 22-56B (for 22-56 models of indoor units) It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 5,6 kW. All the indoor units of the group will operate in the same mode (cooling or heating) M3 EVV 73-140B (for 73-140 models of indoor units) It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 14 kW. All the indoor units of the group will operate in the same mode (cooling or heating) In case 1 only solenoid valve kit is used to control a group of indoor units, only 1 control must be used for the whole group

Solenoid valve controller

VRF VR F

M3 EVVC (B)

www.argoclima.com

99


Distribution joint kits for 3 - way systems p

p

g

(

Position

Part A

Part B

Part C

Part D

Part E

Part F

Part G

Part H

Part I

Part J

Dimension

ø38.1

ø31.75

ø28.58

ø25.4

ø22.22

ø19.05

ø15.88

ø12.7

ø9.52

ø6.35

)

M3DDV22 Discharge pipe

210 G H

GH

55

235

H

H

40

I H

H

92

145

I H

G

55

G H

G

H

H

F F

7

F

HI

77

F

12

F

G F

Liquid pipe

186

69

Suction pipe

136

Insulator

Insulator

Insulator

M3DDV68 Discharge pipe

300 126

112 74 230

55

Insulator

H G

G

55 C A

B

BA

B B

B

90

45

C

C

105

C

HI

50

112

Insulator

Suction pipe

Discharge pipe

490

Liquid pipe I H G

490 300

300 C

C

DE F

ED C

126

C C

112 C

230

G

340

DE F

Insulator

C

EFG

GF E

I H

B

M3DDVE68

G

F E

C

C A F E D

I H G

Liquid pipe

F E D

F

50

Insulator

Insulator

M3DDV135 Suction pipe Discharge pipe

HI

340

D D

C

D

D

EFG

101

83 D

C

D

D E F

E F G

230

Insulator

G

G

F E

GF E

E FG G HI

I H

126

230

G H

EFG G

GF E

E F F

G

F E

I H

D

F

G

16

D

C

D E F

G

130

C

I H G

130

112

D D EF

FED C C

126

DE F

55

16

C

C

FED C C

Liquid pipe

300

130

Suction pipe

50

340

Insulator

Insulator

M3DDVE135 Discharge pipe

Liquid pipe

615 490

375 B

A C C DE F

105

112

C C

D C C

C

DE F

G

G

F E EFG G

GFE

I H

HI

340

50

C

B

315

C

112

B C D

C

53

126

B

180

B A

112

300 B B

I H G

130

Suction pipe

B

A

230

D E F

66

Insulator Insulator

Insulator

VRF

LEGENDA : letter in circle letter not in circle

F F 100

www.argoclima.com

= female side = male side


AWF 22 - 28 - 36 / AWS 56 - 73

AWF 22 - 28 - 36

AWS 56 - 73

VRF VR F

t High wall indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems t New flat panel unit for 2,2 – 2,8 and 3,6 kW models: compact and elegant with its white pearl coloured panel, this new unit can be easily integrated in every type of furniture t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed tangential fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set to a fixed position by remote control t Vertical flap by manual control t Washable air filter t Three-way condensate discharge (right, central and left) t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

101


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

AWF22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 540-450-360 1,3 3 + Auto 35-32-28 46-43-39 230/1/50 0,037 0,038 R410A 6,35(1/4") 12,70(1/2") 10,0 285x825x217

AWS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 720-600-480 2,3 3 + Auto 36-32-28 47-33-39 230/1/50 0,033 0,033 R410A 6,35(1/4") 12,70(1/2") 14 285x995x203

VRF 102

www.argoclima.com

AWF28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 540-450-360 1,6 3 + Auto 35-32-28 46-43-39 230/1/50 0,037 0,038 R410A 6,35(1/4") 12,70(1/2") 10,0 285x825x217

AWS73MH Cooling Heating 7,30 8,00 24.890 27.280 6.280 6.880 960-840-600 4,0 3 + Auto 42-38-35 53-49-46 230/1/50 0,052 0,052 R410A 9,52(3/8") 15,88(5/8") 21 330x1.140x228

AWF36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 600-510-390 2,0 3 + Auto 37-33-29 48-44-40 230/1/50 0,043 0,044 R410A 6,35(1/4") 12,70(1/2") 10,0 285x825x217


ASS 22-28-36-45-56

VRF VR F

t Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set on a fixed position by remote control t Washable air filter t Integrated pump for condensate discharge t Special anti-dripping system on the four air outlets t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

103


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm

ASS22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 700-600-500 0,9 3 + Auto 43-40-37 52-49-46 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 296x575x575 41x730x730

ASS28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 700-600-500 1,0 3 + Auto 43-40-37 52-49-46 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 296x575x575 41x730x730

ASS36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 700-600-500 1,2 3 + Auto 43-40-37 52-49-46 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 296x575x575 41x730x730

ASS45MH Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 750-630-530 2,3 3 + Auto 44-40-37 53-49-46 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 18/2,5 296x575x575 41x730x730

ASS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 750-630-530 2,3 3 + Auto 44-40-37 53-49-46 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 18/2,5 296x575x575 41x730x730

VRF 104

www.argoclima.com


ASS 73 - 106 - 140

VRF VR F

t Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set on a fixed position by remote control t Special system to avoid condensate dripping from air outlet ribs t Washable air filter t Integrated pump for condensate discharge t Special anti-dripping system on the four air outlets t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

105


Technical data PRODUCT NAME Features

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW

Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

mm(inch") mm(inch") Kg mm mm

PRODUCT NAME Features

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW

Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

mm(inch") mm(inch") Kg mm mm

PRODUCT NAME Features

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW

Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) at 2 m Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.)

VRF

ASS 73 ASS 106/140

ASS 73 ASS 106/140

106

mm(inch") mm(inch") Kg mm mm

ASS73MH Cooling Heating 7,30 8,00 24.890 27.280 6.280 6.880 1.140-1.020-840 3,6 3 + Auto 47-45-41 56-54-50 230/1/50 0,175 0,120 R410A 9,52(3/8") 15,88(5/8") 22/6 338x860x860 30x860x860

ASS106MH Cooling Heating 10,60 11,40 36.150 38.880 9.120 9.800 1.920-1.680-1.320 4,6 3 + Auto 53-50-46 62-59-55 230/1/50 0,210 0,150 R410A 9,52(3/8") 15,88(5/8") 27/8 338x1.150x860 30x1.150x860

ASS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.920-1.680-1.320 6,3 3 + Auto 53-50-46 62-59-55 230/1/50 0,210 0,150 R410A 9,52(3/8") 15,88(5/8") 27/8 338x1.150x860 30x1.150x860

A (mm)

B (mm)

820 1 110

566 856

A (mm)

B (mm)

C (mm)

D (mm)

E (mm)

157 157

182 182

261 291

308 338

124 124

www.argoclima.com

Weight (kg)

28 35


ADS 22 - 28 - 36

VRF VR F

t Ducted indoor unit with optional two-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.) t Washable air filter t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

107


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.-m.-l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.-m.-l.) at plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.-m.-l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.-m.-l.) at plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity

VRF

Air flowrate Indoor (h.-m.-l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.-m.-l.) at plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

108

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

ADS22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 600-510-440 0,8 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771

ADS28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 600-510-440 0,8 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771

ADS36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 600-510-440 1,5 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771

www.argoclima.com


ADS 45 - 56 - 64

VRF VR F

t Ducted indoor unit with optional three-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.) t Washable air filter t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

109


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.-m.-l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.-m.-l.) Sound pressure Indoor (h.-m.-l.) at plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity

VRF

Air flowrate Indoor (h.-m.-l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.-m.-l.) at plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.)

110

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm

AD45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 875-600-400 2,3 5-7 3 + Auto 54-47-42 45-38-33 < 20 230/1/50 0,138 0,138 R410A 6,35(1/4") 12,7(1/2") 200 35 266x1.132x571 266x1.132x771

ADS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 875-600-400 2,3 5-7 3 + Auto 54-47-42 45-38-33 < 20 230/1/50 0,138 0,138 R410A 6,35(1/4") 12,7(1/2") 200 35 266x1.132x571 266x1.132x771

AD64MHG Cooling Heating 6,40 7,00 21.850 23.870 5.500 6.020 1000-700-600 2,6 5-7 3 + Auto 57-49-46 48-40-37 < 20 230/1/50 0,136 0,136 R410A 9,52(3/8") 15,88(5/8") 200 35 266x1.132x571 266x1.132x771

www.argoclima.com


ADS 73 - 106 - 140

ADS 106 - 140

ADS 73

VRF VR F

t Three/Four way Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel� feature and temperature sensor indoor the remote control t Dry function t Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm W.C.) t Integrated pump for condensate discharge t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

111


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity

VRF

Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.)

112

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm Kg mm

Units kW BTU/h kcal/h m3/h l/h mm W.G. n째 dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm Kg mm

www.argoclima.com

ADS73MH Cooling Heating 7,3 8,0 24.890 27.280 6.280 6.880 1.080-900-780 3,5 5,1-9,4 3 + Auto 43-39-36 34-30-27 < 20 230/1/50 0,195 0,183 R410A 9,52(3/8") 15,88(5/8") 200 32 310x1.000x630

ADS106MH Cooling Heating 10,6 11,4 36.140 38.880 9.120 9.800 1.800-1.560-1.260 4,2 8,1-12,4 3 + Auto 47-42-40 38-33-31 < 20 230/1/50 0,327 0,315 R410A 9,52(3/8") 15,88(5/8") 200 47 310x1.480x630

ADS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.980-1.560-1.320 6,6 8-11,5 3 + Auto 49-46-42 40-37-33 < 20 230/1/50 0,325 0,313 R410A 9,52(3/8") 15,88(5/8") 200 47 310x1.480x630


ACS 73 - 106 - 140

VRF VR F

t Underceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set on a fixed position by remote control t Vertical flap by manual control t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

113


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Sound power Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

VRF 114

www.argoclima.com

ACS73MH Cooling Heating 7,3 8,0 24.890 27.280 6.280 6.880 1.098-900-840 3,0 3 + Auto 38-36-33 49-47-44 230/1/50 0,043 0,042 R410A 9,52(3/8") 15,88(5/8") 25,0 210x1.180x680

ACS106MH Cooling Heating 10,6 11,4 36.140 38.880 9.120 9.800 1.650-1.380-1.200 3,9 3 + Auto 41-38-35 52-49-46 230/1/50 0,074 0,073 R410A 9,52(3/8") 15,88(5/8") 33 210x1.595x680

ACS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.800-1.560-1.320 5,6 3 + Auto 43-40-37 54-51-48 230/1/50 0,086 0,085 R410A 9,52(3/8") 15,88(5/8") 33,0 210x1.595x680


FC 22 - 28 - 36 - 45 - 56 - 64

VRF VR F

t Floor/ceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Horizontal flap swinging or to be set on a fixed position by remote control t Vertical flap by manual control t Washable air filter t Optional active carbon filters t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

115


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

FC22MHG Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 700-590-500 1,0 3 + Auto 47-43-38 55-51-46 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190

FC28MHG Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 700-590-500 1,2 3 + Auto 47-43-38 55-51-46 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190

FC36MHG Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 700-590-500 1,3 3 + Auto 47-43-38 55-51-46 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190

FC45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 830-760-665 2,3 3 + Auto 52-49-46 60-57-54 230/1/50 0,088 0,088 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190

FC56MHG Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 830-760-665 2,3 3 + Auto 52-49-46 60-57-54 230/1/50 0,088 0,088 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190

FC64MHG Cooling Heating 6,40 7,00 21.850 23.870 5.500 6.020 830-760-665 2,3 3 + Auto 52-49-46 60-57-54 230/1/50 0,088 0,088 R410A 9,52(3/8") 15,88(5/8") 23,5 680x900x190

VRF 116

www.argoclima.com


SD 22 - 28 - 36 - 45 - 56 - 64

VRF VR F

t Slim ducted indoor unit, available for floor or wall or ceiling installation, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t Especially projected for hotel applications t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) t “I Feel” feature and temperature sensor indoor the remote control t Dry function t New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion t Washable air filter t Optional active carbon filters t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor

www.argoclima.com

117


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.-m.-l.) at 2m Sound power Indoor (h.-m.-l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.)

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

Units kW BTU/h kcal/h m3/h l/h n째 dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm

SD22MHG Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 470-380-340 1,0 3 + Auto 37-30-26 45-38-34 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190

SD28MHG Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 470-380-340 1,2 3 + Auto 37-30-26 45-38-34 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190

SD36MHG Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 470-380-340 1,3 3 + Auto 37-30-26 45-38-34 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190

SD45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 620-540-450 2,3 3 + Auto 45-41-33 53-49-41 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190

SD56MHG Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 620-540-450 2,3 3 + Auto 45-41-33 53-49-41 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190

SD64MHG Cooling Heating 6,40 7,00 21.850 23.870 5.500 6.020 680-600-520 3,3 3 + Auto 49-45-40 57-53-48 230/1/50 0,088 0,088 R410A 9,52(3/8") 15,88(5/8") 25 585x890x190

VRF 118

www.argoclima.com


ADPS 140 - 224 - 280

ADPS 140

ADPS 224 - 280

VRF VR F

t Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems t High static pressure, low noise t Easy placement in any type of environment t Automatic change-over between cooling and heating modes t Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room t Night set back capability t To be managed by wired and wireless controllers of Multiset V.R.F. DC Inverter systems (all optional) t “I Feel� feature and temperature sensor indoor the remote control t Dry function t Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor t Valve Kit to prevent gas accumulation: with the exception of mono systems, it takes 2 valves each unit of models 224 and 280 if connected to the same outdoor unit in a multi-system

www.argoclima.com

119


Technical data PRODUCT NAME Features Cooling/Heating capacity Air flowrate (h.m.l.) External static pressure (max) Fan speeds Sound power (h.m.l.) Sound pressure (h.m.l.) Power supply Running consumption (min.-med.-max.) Running current (min.-med.-max.) Liquid pipe diameter Gas pipe diameter Net weight Net dimensions (H./W./D.)

ADPS140MH Units kW m K Pa n째 dB(A) dB(A) V/Ph/Hz kW A mm(inch") mm(inch") Kg mm

Cooling Heating 14,0 16,0 2160/2100/1980 167 3 + Auto 47/46/44 58/57/55 230/1/50 0,60/0,66/0,71 0,60/0,66/0,71 2,80/2,90/3,00 2,80/2,90/3,00 9,52(3/8") 15,88(5/8") 54 450/1065/620

Units kW m K Pa n째 dB(A) dB(A) V/Ph/Hz kW A mm(inch") mm(inch") Kg mm

Cooling Heating 22,4 25 3360/3190/2980 176 3 + Auto 48/47/46 59/58/57 230/1/50 0,87/0,90/0,93 0,87/0,90/0,93 4,50/4,06/4,07 4,05/4,06/4,07 9,52(3/8") 19,05(3/4") 110 467/1428/1230

Units kW m K Pa n째 dB(A) dB(A) V/Ph/Hz kW A mm(inch") mm(inch") Kg mm

Cooling Heating 28,0 31,50 4320/4200/3960 216 3 + Auto 51/50/49 62/61/60 230/1/50 1,27/1,33/1,39 1,27/1,33/1,39 6,04/6,06/6,07 6,04/6,06/6,07 9,52(3/8") 22,22 (7/8") 120 467/1428/1230

PRODUCT NAME Features Cooling/Heating capacity Air flowrate (h.m.l.) External static pressure (max) Fan speeds Sound power (h.m.l.) Sound pressure (h.m.l.) Power supply Running consumption (min.-med.-max.) Running current (min.-med.-max.) Liquid pipe diameter Gas pipe diameter Net weight Net dimensions (H./W./D.)

ADPS224MH

PRODUCT NAME Features Cooling/Heating capacity Air flowrate (h.m.l.) External static pressure (max) Fan speeds Sound power (h.m.l.) Sound pressure (h.m.l.) Power supply Running consumption (min.-med.-max.) Running current (min.-med.-max.) Liquid pipe diameter Gas pipe diameter Net weight Net dimensions (H./W./D.)

ADPS280MH

VRF 120

www.argoclima.com


Controlli controls and accessories

Schedule timer able to manage up to 64 indoor units with customized programming of all features, on/off cycles, etc.

Infrared remote controller to be used with cassette and floor/ceiling indoor units

System controller to be used to manage only on/off cycles for a system up to 16 groups / 64 indoor units, to be used in matching with other controllers (remote controllers, system controllers, etc.)

Infrared remote controller to be used with underceiling indoor units

System controller to be used to manage and program a system up to 16 groups / 64 indoor units, with or without remote controllers; it can be matched with schedule timer and intelligent controller

Infrared remote controller to be used, in matching with a special infrared receiver, with the full range of indoor units; it shows the operation status of the air-conditioner

Interface PLC for outdoor units: can control up to 4 outdoor units. Required for “Demand” control, typical of 3-way systems

Standard wired remote controller with full features control, self-diagnostic and centralized programming capabilities

New standard wired remote controller equipped with weekly timer,caracterized by full features control, selfdiagnostic and centralized programming capabilities.

Simplified wired remote controller to be used with the full range of indoor units; it controls all the main features

New Touch Screen Intelligent Controller for WEB: to be used to manage and program a system up to 256 indoor units, organized in 4 groups of 64 units each, also without wired controllers; it can be matched with the schedule timer and in case of three/fourgroup installations it must be connected with the communication adapter on the outdoor unit. User friendly touch screen operation. Web browser: it allows to control VRF system by its own PC at home using an Internet connection with a LAN cable.

Remote sensor to be used with the full range of indoor units to detect the room temperature when no remote controller sensor or body sensor is used: suggested for air-conditioner systems without remote controller

www.argoclima.com

VRF VR F

Infrared remote controller to be used with high-wall indoor units

121


Multiset v.r.f. controls functions

INDIVIDUALS CONTROLS

TIMER

Picture

Description

Standard wired Control

Model

REM HW standard

Standard wired Control + Timer REM HW TM

Simplified wired Control

Infrared remote Control

Weekly Timer

REM HWS

REM HL

REM HW T -

17 / 27 °C

17 / 27 °C

17 / 27 °C

17 / 27 °C

16 / 26 °C

16 / 26 °C

16 / 26 °C

16 / 26 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

3 + auto

3 + auto

3 + auto

3 + auto

-

-

Functions

-

-

temperaure +/-

temperature +/-

temperature +/-

temperature +/-

flap

flap

flap

flap

timer 72

Other

N° of units controlled

weekly timer

timer 72 h

sensor t.(2)

sensor t.(2)

sensor t.(2)

Fault alarm

Fault alarm

Fault alarm

Dirty filter

Dirty filter

Dirty filter

max. 8

max. 8

It works only with a secondary control

It works only with a secondary control

max. 8

It works only with a secondary control

VRF 122

www.argoclima.com

sensor t.(2)

weekly timer Interdiction to use indoor unit control functions

-

-

-

-

max. 8

1 group with 64 units 8 groups with 8 units 4 groups with 16 units

It works only with a secondary control

6 daily programs x 7 days + holiday

You can select 6 different addresses

Power supply by REM HW-64 S or T10-PCB indoor unit connector


Multiset v.r.f. controls functions

GROUP CONTROLS

Picture

Description

System control

ON/OFF System control

Intelligent touch controller

Model

REM HW 64S

REM HW 16S

REM HW 256S

Adapter for control system

LonWorks Interface

PLC Interface

REM HWAS

LWI

IEM

17 / 27 °C

17 / 27 °C

16 / 26 °C

16 / 26 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

18 / 30 °C

3 + auto

3 + auto

temperature +/-

temperature +/-

flap

flap

-

-

-

-

-

-

18 / 30 °C

18 / 30 °C

Functions

16 / 26 °C

-

-

18 / 30 °C

3 + auto

3 + auto

temperature +/-

temperature +/-

flap

Interdiction to use indoor unit control functions

17 / 27 °C

16 / 26 °C

18 / 30 °C

-

17 / 27 °C

flap

-

-

timer Interdiction to use indoor unit control functions

-

Malfunctions report

Fault alarm -

-

Fault alarm

-

-

-

16 groups of 4 units (max 64 units)

16 groups of 4 units (max 64 units)

The control central can perform functions of remote control and system control, Intelligent Controller

You must use the individual controls

Dirty filter 16 groups of 4 units (max 64 units)

16 groups of 4 units (max 64 units)

64 units x 4 systems max 256 indoor units 2 systems, 64 units x 2 30 units x 4 systems max 128 units max 120 outdoor units Over 3 systems to use with you must use REMHW256S REMHWAS (max 7) (+3 systems) Monitoring and calculation of consumption distribution

VRF VR F

Other

N° of units controlled

www.argoclima.com

123


REC 03/06/10/14/19/25/30/40

t REC heat recovery units, characterized by small size and easy to install, are suitable for residential and commercial applications t Regulations require forced ventilation in realizing air conditioning and air treatment systems, with expulsion of air treated and consequent increase in energy consumption and costs. t In all these cases REC heat recovery units allow over 50% of energy saving and ensure an adequate environmental comfort through the use of a static heat exchanger made of aluminium. t REC heat recovery units are available in 8 sizes with airows from 300 to 4000 m3 /h and high static pressure. t They work both in the summer and in winter. t Particularly suitable for false ceiling installation, they may be appropriately ducted allowing air supply and air suction directly in the room. t High efďŹ ciency aluminium plated heat recovery, with airows separated by special seals. t The side panels are fully removable, made of double-layer plate with thermal and sound insulation in polyethylene / polyester with an average thickness of 10 mm for models REC 03-06-10 and 20mm for the other models. t In the lower part of the recovery unit is installed a condensate tank in stainless steel, with drain downward. t The fan group consists of 2 centrifugal fans with double inlet (for the REC 03 model single inlet) separated, one for the recovery fresh air, the other for the exhaust air. t Single-phase electric motors (3-phase only for REC 40), 2 or 3 speeds. t The fans are mounted on anti-vibration easy removable support, which ensures a very low noise even at maximum speed. t They are also equipped with air ďŹ lters with performance class G3, easily removable from each side of the unit and regenerate. t REC heat recovery units are available also in vertical version.

VRF

MAIN ACCESSORIES t 4QFFE DPOUSPM 3&$ $/5- 4 $76 t 3FNPUF DPOUSPM QBOFM 1$3 t "EEJUJPOBM )FBUJOH SFTJTUBODF &) t *OUFSOBM XBUFS IFBUJOH DPJM 4,8 t )JHI FGmDJFODZ mMUFST '5, t 3PVOE BEBQUFS GPS DJSDVMBS EVDU #$$

124

www.argoclima.com


03

06

10

14

19

25

30

40

990 750 270 162 100 275 153 195 195 170 197 ½” 39

990 750 270 162 100 275 153 195 195 170 197 ½” 41

1150 860 385 230 240 218 330 267 245 205 238 225 ½” 68

1350 900 410 230 240 270 337 267 241 241 224 241 ½” 91

1450 900 470 280 240 270 337 327 241 241 284 241 ½“ 99

1700 1230 490 305 306 270 502 347 323 323 290 323 ½“ 140

1700 1230 530 305 339 297 502 387 308 345 331 323 ½“ 155

1700 1230 630 405 339 297 502 487 308 345 377 323 ½“ 179

TYPE A INSIDE

OUTSIDE

Fresh air

Exhaust air

A90

R90

E90

M90

Return air

Supply air

VRF VR F

MODELLO MODEL A mm B mm C mm D mm L mm H mm L1 mm H1 mm E mm E1 mm F mm G mm I kg

www.argoclima.com

125


MODELS Airflow rate

External static pressure

Max Med Min Max Med Min

m3/h

Pa

Max 1 m sound pressure level

Recovery efficiency(1)

Saved power(1)

Med Min Max Med Min Max Med Min

dB (A)

%

kW

REC 03 300 200 100 100 160 167

REC 06 500 300 150 100 129 127

REC 10 1000 900 800 90 70 47

51,1

51,1

52,2

62,3

49,7

47,4

48,8

56,9

44,3 52,0 57,0 66,4 1,4 1,0 0,6

41,0 56,1 62,5 71,1 2,6 1,7 1,0

45,3 53,4 54,8 56,3 4,9 4,5 4,1

45,6 52,1 53,5 58,4 6,7 6,1 4,5

8,0

9,0

8,4

8,0

9,3

10,6

8,7

8,4

11,6

12,8

9,1

9,6

Max Supply temperature(1)

Med

°C

Min

REC 14 1400 1250 850 145 133 113

FAN Shaft power

W

2x60

2x60

2x147

2x350

Maximum current

A

1,2

1,4

3

5,8

Fan speeds

3

3

3

3

Poles

2

2

4

4

Protection degree - minimum

IP

20

V/ph/Hz

230/1/50

B

Temperature class - minimum Power supply DIMENSIONS / WEIGHT - REC Width/Length/Height

mm

990/750/270

990/750/270

1150/860/385

1350/900/410

Net weight

Kg

39

41

68

91

(1)

At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.

MODELS Airflow rate

External static pressure

Max Med Min Max Med Min

m3/h

Pa

Max 1 m sound pressure level

Recovery efficiency(1)

Saved power(1)

Med Min Max Med Min Max Med Min

dB (A)

%

kW

Max Supply temperature(1)

Med

°C

Min

REC 19 1900 1570 1340 120 121 119

REC 25 2500 1830 1100 110 112 112

REC 30 3200 2500 1800 170 159 144

REC 40 4000 3000 170 147 62,1

58,4

56,0

58,8

53,7

51,0

53,5

-

42,1 51,8 54,1 56,1 9,0 7,8 6,9

44,6 57,6 61,5 67,7 13,2 10,3 8,6

51,1 56,0 59,0 63,1 16,4 13,5 10,4

54,9 55,7 59,2 20,3 16,2

7,9

9,4

9,0

8,9

8,5

10,4

9,8

-

9,0

11,9

10,8

9,8

FAN Shaft power

W

2x350

2x350

2x550

2x750

Maximum current

A

6,2

6

11,4

6,2

Fan speeds

3

3

3

2

Poles

4

4

4

4

Protection degree - minimum

IP

20 B

Temperature class - minimum Power supply

230/1/50

V/ph/Hz

400/3/50

DIMENSIONS / WEIGHT - REC

VRF

Width/Length/Height

mm

1450/900/470

1700/1230/490

1700/1230/530

1700/1230/630

Net weight

Kg

99

140

155

179

(1)

126

At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.

www.argoclima.com


VRF VR F

Notes:

www.argoclima.com

127


Notes:

VRF 128

www.argoclima.com


VRF VR F

Notes:

www.argoclima.com

129


Notes:

VRF 130

www.argoclima.com


Regulations on energy efďŹ ciency labelling Argo air conditioners are compliant with the most recent European Standards for the reduction of energy consumption and atmospheric pollution. The labels that indicate the energy efficiency class were introduced with European Community directive 2002/31/EC, which makes reference to standard EN14511, which in turn provides precise reference tables for the energy efficiency class classification. Energy efficiency labels are applied to products (air conditioners with a cooling power of up to 12 kW) on display at retail outlets. They are provided to inform customers of the efficiency of the product they intend to purchase. The label is divided into two parts, a generic coloured label and an adhesive black and white label that must be applied over the coloured one. Our company provides both the labels mentioned above. The generic label is supplied directly at retail outlets, whilst the specific one is placed inside the packaging of each air conditioner sold. In the event that the specific label has been lost, each retail outlet should be able to provide another immediately by downloading it from the Internet or requesting it from our marketing dept. The energy efficiency label indicates the energy class; class A is the highest and is awarded based on tables that compare thermal efficiency and energy consumption. The indicators of the above ratio are known as: E.E.R. = Energy Efficiency Ratio: this is the ratio between cooling power (in kw) and power consumption in cooling mode (in kw). C.O.P. = coefficient of performance: this is the ratio between heating power (in kw) and power consumption in heating mode (in kw).

Example of an energy efďŹ ciency label:

1) generic - coloured

2) specific - black/white

131


702012201 - 03/2012

w w w. a r g o c l i m a . c o m

The manufacturing company doesn’t assume any responsibility for mistakes or omissions contained in this catalogue and reserves the right to make at any time, even without notice, any change considered suitable for technical or commercial purposes to its products.

Argo is a brand of

, European leader in Air Conditioning, Heating and Air Treatment.

orangotown.com

headquarter Via Varese, 90 21013 Gallarate (VA) ITALY Tel: + 39 0331 755111 Fax: + 39 0331 776240 www.argoclima.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.