SupplyNet
速
Residential Sprinkler Systems
June 2010
Residential Sprinkler Range Pendent and Recessed Pendent Sprinklers
Available in 68°C and 79°C; Recessed Adjustment up to 16mm (5/8”) 45 (3.1) K-factor
VK435, Part No. 13203 Tech Data Page Sprinkler 140e
Room Size m/ft
• Lowest listed flows 75.7 lpm (20 gpm) • Can optimize NFPA 13 residential designs when combined with larger K factor residential sprinklers.
62 (4.3) K-factor
VK430, Part No. 09530 Tech Data Page Sprinkler 140a • Continually listed by UL since 1995
71 (4.9) K-factor
VK468, Part No. 13637 Tech Data Page Sprinkler 149m • Listed with beam ceilings up to 6.1m x 6.1m (20”)
75 (5.2) K-factor
VK466, Part No. 13781 Tech Data Page Sprinkler 141j • Listed with beam ceilings up to 6.1m x 6.1m (20”)
VK432, Part No. 10050 Tech Data Page Sprinkler 141a • Continually listed by UL since 1997
84 (5.8) K-factor
VK472, Part No. 16130 Tech Data Page Sprinkler 148o • Larger K-Factor provides lowest starting pressure in NFPA 13 applications (0.1 density)
107 (7.4) K-factor
VK458, Part No. 13230 Tech Data Page Sprinkler 140w • Larger K-Factor provides lowest starting pressure in NFPA 13 applications (0.1 density)
0.58 (8.4) 0.72 (10.4)
N/A N/A
N/A N/A
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
45 (12.0) 49 (13.0) 49 (13.0) 64 (17.0) 80 (21.0)
0.54 (7.8) 0.63 (9.1) 0.63 (9.1) 1.08 (15.6) 1.64 (23.9)
68 (18.0) 68 (18.0) 68 (18.0) N/A N/A
1.21 (17.5) 1.21 (17.5) 1.21 (17.5) N/A N/A
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
49 (13.0) 49 (13.0) 49 (13.0) 64 (17.0) 76 (20.0)
0.48 (7.0) 0.48 (7.0) 0.48 (7.0) 0.83 (12.0) 1.15 (16.7)
80 (21.0) 80 (21.0) 80 (21.0) 80 (21.0) 80 (21.0)
1.27 (18.4) 1.27 (18.4) 1.27 (18.4) 1.27 (18.4) 1.27 (18.4)
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
53 (14.0) 53 (14.0) 53 (14.0) 64 (17.0) 76 (20.0)
0.50 (7.2) 76 (20.0) 0.50 (7.2) 76 (20.0) 0.50 (7.2) 76 (20.0) 0.74 (10.7) 761 (20.0) 1.02 (14.8) 761 (20.0)
1.02 (14.8) 1.02 (14.8) 1.02 (14.8) 1.02 (14.8) 1.02 (14.8)
Flows shown for 68°C (155°F); 79°C (175°F).
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
61 (16.0) 72 (19.0) 72 (19.0) 80 (21.0) 91 (24.0)
0.58 (8.5) 80 (21.0) 1.01 (14.6) 0.82 (11.9) 80 (21.0) 1.01 (14.6) 0.82 (11.9) 80 (21.0) 1.01 (14.6) 1.01 (14.6) 83 (22.0) 1.10 (16.0) 1.31 (19.0) 106 (28.0) 1.79 (25.9)
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
61 (16.0) 61 (16.0) 61 (16.0) 64 (17.0) 80 (21.0)
0.52 (7.6) 0.52 (7.6) 0.52 (7.6) 0.59 (8.6) 0.90 (13.1)
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
76 (20.0) 76 (20.0) 76 (20.0) 83 (22.0) 91 (24.0)
0.50 (7.3) 0.50 (7.3) 0.50 (7.3) 0.61 (8.8) 0.73 (10.5)
1
www.vikinggroupinc.com
Sloped Ceiling 33.7° Flow Pressure lpm/gpm bar/psi
3.7 x 3.7 (12 x 12) 34 (9.0) 4.3 x 4.3 (14 x 14) 38 (10.0)
1
79 (5.5) K-factor
Horizontal Ceiling Flow Pressure lpm/gpm bar/psi
761 (20.0) 761 (20.0) 761 (20.0) 871 (23.0) 911 (24.0)
0.50 (7.3) 0.50 (7.3) 0.50 (7.3) 0.67 (9.7) 0.73 (10.5)
Flows shown for 68°C (155°F); see data page for flows at 79°C (175°F).
June 2010
Flat Plate Concealed Pendent Sprinklers
Cover Plate Temp = 57°C (135°F); Adjustment up to 15mm (1/2”) Room Size m/ft 71 (4.9) K-factor
VK456, Part No. 13620A, 13750 Tech Data Page Sprinkler 147e • Sprinkler Temp = 60°C (140°F)
71 (4.9) K-factor
VK457, Part No. 14694A Tech Data Page Sprinkler 147v • Sprinkler Temp = 74°C (165°F) • Available with either standard, large or square cover plate
84 (5.8) K-factor
VK474, Part No. 15709A Tech Data Page Sprinkler 148h • Sprinkler Temp = 74°C (165°F) • Available with either standard, large or square cover plate
Slope up to 9.5° (2/12) Slope up to 33.7° (8/12) Flow Pressure Flow Pressure lpm/gpm bar/psi lpm/gpm bar/psi
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
49 (13) 49 (13) 53 (14) 64 (17) 87 (23)
0.48 (7.0) 0.48 (7.0) 0.56 (8.2) 0.83 (12.0) 1.52 (22.0)
64 (17) 64 (17) 64 (17) 98 (26) 98 (26)
0.83 (12.0) 0.83 (12.0) 0.83 (12.0) 1.94 (28.2) 1.94 (28.2)
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
49 (13) 49 (13) 49 (13) 64 (17) 76 (20)
0.48 (7.0) 0.48 (7.0) 0.48 (7.0) 0.83 (12.0) 1.15 (16.7)
107 (26) 107 (26) 107 (26) 117 (31) 117 (31)
1.94 (28.2) 1.94 (28.2) 1.94 (28.2) 2.76 (40.0) 2.76 (40.0)
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
61 (16) 61 (16) 61 (16) 72 (19) 87 (23)
0.52 (7.6) 0.52 (7.6) 0.52 (7.6) 0.74 (10.7) 1.10 (15.7)
N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
49 (13) 49 (13) 49 (13) 64 (17) 77 (20)
0.48 (7.0) 0.48 (7.0) 0.48 (7.0) 0.83 (12.0) 1.15 (16.7)
981 (26) 981 (26) 981 (26) 981 (26) 981 (26)
1.94 (28.2) 1.94 (28.2) 1.94 (28.2) 1.94 (28.2) 1.94 (28.2)
53 (14) 53 (14) 53 (14) 64 (17) 76 (20)
0.50 (7.2) 0.50 (7.2) 0.50 (7.2) 0.74 (10.7) 1.02 (14.8)
87 (23) 87 (23) 87 (23) 87 (23) 87 (23)
1.35 (19.6) 1.35 (19.6) 1.35 (19.6) 1.35 (19.6) 1.35 (19.6)
3.7 x 3.7 (12 x 12) 76 (20) 4.3 x 4.3 (14 x 14) 76 (20) 4.9 x 4.9 (16 x 16) 76 (20) 5.5 x 5.5 (18 x 18) 87 (23) 6.1 x 6.1 (20 x 20) 106 (28)
0.50 (7.3) 0.50 (7.3) 0.50 (7.3) 0.67 (9.7) 0.99 (14.3)
83 (22) 83 (22) 83 (22) 106 (28) 106 (28)
0.61 (8.8) 0.61 (8.8) 0.61 (8.8) 0.99 (14.3) 0.99 (14.3)
Domed Concealed Pendent Sprinklers
Cover Plate Temp = 57°C (135°F); Adjustment up to 15mm (1/2”) 71 (4.9) K-factor
VK468, Part No. 13637A-X, 12207 Tech Data Page Sprinkler 149q • Sprinkler Temp = 68°C (155°F) and 79°C (175°F)
1
75 (5.2) K-factor
VK466, Part No. 13781A-X Tech Data Page Sprinkler 141r-w • Sprinkler Temp = 68°C (155°F), unless otherwise noted
107 (7.4) K-factor
VK458, Part No. 13230ABX, 12207 Tech Data Page Sprinkler 140q • Sprinkler Temp = 68°C (155°F) • Larger K-Factor provides lowest starting pressure in NFPA 13 applications (0.1 density)
Sloped ceiling listing for 68°C (155°F) only.
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
Flush Pendent Sprinklers
Available in 74°C (165°F); Vertical Adjustment up to 16mm (5/8”) 71 (4.9) K-factor
VK476, Part No. 15630 Tech Data Page Sprinkler 145h • Sprinkler Temp = 74°C (165°F) • Listed for ceilings with beams up to 35,6 cm (14”) in depth. See datasheet for complete design and installation guidelines. • Sprinkler and outer ring sold together
June 2010
Room Size m/ft 3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 6.1 x 6.1 (20 x 20)
Slope up to 9.5° (2/12) Slope up to 18.4° (4/12) Flow lpm/gpm
Pressure bar/psi
Flow lpm/gpm
Pressure bar/psi
49 (13) 49 (13) 49 (13) 64 (17) 80 (21)
0.48 (7.6) 0.48 (7.6) 0.48 (7.6) 0.83 (12) 1.27 (18.4)
91 (24) 91 (24) 91 (24) 91 (24) 91 (24)
1.65 (24) 1.65 (24) 1.65 (24) 1.65 (24) 1.65 (24)
www.vikinggroupinc.com
Horizontal Sidewall and Recessed Horizontal Sidewall Sprinklers Available in 68°C (155°F) and 79°C (175°F); Recessed Adjustment up to 16mm (5/8”) 58 (4.0) K-factor
VK452, Part No. 13140 Tech Data Page Sprinkler 143g • Patent-pending “flow shaper” design provides the ultimate combination of low flows and starting pressures
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16)
VK453, Part No. 13389 Tech Data Page Sprinkler 143w
1
VK450, Part No. 12357 Tech Data Page Sprinkler 143j • Unique offset orifice design (patent pending) • Only residential horizontal sidewall to offer a 6.7m (22’) throw
Pressure bar/psi
Flow lpm/gpm
42 (11) 46 (12) 57 (15)
0.52 (7.6) 0.62 (9.0) 0.97 (14.0)
46 (12) 50 (13) 57 (14)
0.62 (9.0) 0.73 (10.6) 0.97 (14.0)
0.62 (9.0) 0.73 (10.6) 1.10 (16.0) 1.25 (18.1) 2.48 (36.0) 1.56 (22.6) 2.48 (36.0)
Flows shown for 68°C (155°F); 79°C (175°F) available at 68.1 (18.0) / 1.39 (20.3).
Down the slope up to 9.5° (2/12) 3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 4.9 x 5.5 (16 x 18) 4.9 x 6.1 (16 x 20) 4.9 x 6.71 (16 x 22) 1
1
45 (12) 53 (14) 68 (18) 68 (18) 83 (22) 98 (26)
0.56 (8.2) 0.77 (11.1) 1.27 (18.4) 1.27 (18.4) 1.89 (27.4) 2.64 (38.3)
76 (20) 76 (20) 76 (20) 76 (20) 95 (25) N/A
1.56 (22.7) 1.56 (22.7) 1.56 (22.7) 1.56 (22.7) 2.44 (35.4) N/A
Down the slope up to 33.7° (8/12) 3.7 x 3.7 (12 x 12) 45 (12) 0.56 (8.2) 76 (20) 4.3 x 4.3 (14 x 14) 53 (14) 0.77 (11.1) 76 (20) 4.9 x 4.9 (16 x 16) 68 (18) 1.27 (18.4) 76 (20) 4.9 x 5.5 (16 x 18) 68 (18) 1.27 (18.4) 76 (20) 4.9 x 6.1 (16 x 20) 83 (22) 1.89 (27.4) 95 (25)
1.56 (22.7) 1.56 (22.7) 1.56 (22.7) 1.56 (22.7) 2.44 (35.4)
Sprinkler available in 68°C (155°F) only and is surface mounted only.
Sprinkler available in 68°C (155°F) only and is surface mounted only.
Across the slope up to 18.4° (4/12) 3.7 x 3.7 (12 x 12) 68 (18) 1.27 (18.4) 76 (20) 4.3 x 4.3 (14 x 14) 68 (18) 1.27 (18.4) 76 (20) 4.9 x 4.9 (16 x 16) 68 (18) 1.27 (18.4) 76 (20) 62 (4.3) K-factor
Pressure bar/psi
Flows shown for 68°C (155°F); 79°C (175°F) available at 68.1 (18.0) / 1.39 (20.3).
Down the slope up to 9.5° (2/12) 3.7 x 3.7 (12 x 12) 42 (11) 0.52 (7.6) 46 (12) 4.3 x 4.3 (14 x 14) 46 (12) 0.62 (9.0) 49 (13) 4.9 x 4.9 (16 x 16) 61 (16) 1.10 (16.0) 61 (16) 4.9 x 5.5 (16 x 18) 61 (16) 1.10 (16.0) 641 (17) 4.9 x 6.1 (16 x 20) 87 (23) 2.28 (33.1) 91 (24) 4.9 x 6.7 (18 x 18) 72 (19) 1.56 (22.6) 72 (19) 5.5 x 6.1 (18 x 20) 92 (24) 2.48 (36.0) 91 (24)
• Patent-pending “flow shaper” design provides the ultimate combination of low flows and starting pressures
60 (4.2) K-factor
Flow lpm/gpm
Down the slope up to 9.5° (2/12)
1
58 (4.0) K-factor
102-152mm down from ceiling 152-305m down from ceiling
Room Size m/ft
VK440, Part No. 09787 Tech Data Page Sprinkler 142d
1.56 (22.7) 1.56 (22.7) 1.56 (22.7)
Down the slope up to 9.5° (2/12) 3.7 x 3.7 (12 x 12) 72 (19) 1.35 (19.5) N/A 4.3 x 4.3 (14 x 14) 80 (21) 1.64 (23.9) N/A
N/A N/A
Down the slope up to 33.7° (8/12) 3.7 x 3.7 (12 x 12) 72 (19) 1.35 (19.5) N/A
N/A
Flat Plate Concealed HSW Sprinklers Cover Plate Temperature = 57°C (135°F) 58 (4.0) K-factor
VK480, Part No. 16116AC Tech Data Page Sprinkler 153a
Room Size m/ft
• Sprinkler Temp = 74°C (165°F) • Uses large cover plate (3-5/16” diameter, p/n 16207
3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 5.5 x 5.5 (18 x 18) 1 2
www.vikinggroupinc.com
102-152mm down from ceiling 152-305m down from ceiling Flow lpm/gpm
Pressure bar/psi
Flow lpm/gpm
Pressure bar/psi
421 (11) 491 (13) 611 (16) 641 (17)
0.52 (7.6) 0.73 (10.6) 1.10 (16.0) 1.25 (18.1)
462 (12) 532 (14) 612 (16) 682 (18)
0.62 (9) 0.84 (12.3) 1.10 (16) 1.40 (20.3)
Centreline of sprinkler located 4-3/8” to 6-3/8” below the ceiling. Centreline of sprinkler located 6-3/8” to 12-3/8” below the ceiling.
June 2010
Horizontal Sidewall and Recessed Horizontal Sidewall Sprinklers (continued) Available in 68°C (155°F) and 79°C (175°F); Recessed Adjustment up to 16mm (5/8”) 79 (5.5) K-factor
VK442, Part No. 12119 Tech Data Page Sprinkler 146a
102-152mm down from ceiling 102-305m down from ceiling
Room Size m/ft
Flow lpm/gpm
Pressure bar/psi
Flow lpm/gpm
Pressure bar/psi
Down the slope up to 9.5° (2/12) 3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 4.9 x 5.5 (16 x 18)
80 (21) 83 (22) 91 (24) 102 (27)
1.01 (14.6) 1.01 (14.6) 1.31 (19.0) 1.66 (24.1)
80 (21) 83 (22) N/A N/A
Down the slope up to 33.7° (8/12) 3.7 x 3.7 (12 x 12) 80 (21) 1.01 (14.6) N/A 4.3 x 4.3 (14 x 14) 83 (22) 1.01 (14.6) N/A 4.9 x 4.9 (16 x 16) 91 (24) 1.31 (19.0) N/A 4.9 x 5.5 (16 x 18) 106 (28) 1.79 (25.9) N/A
84 (5.8) K-factor
VK460, Part No. 13933 Tech Data Page Sprinkler 152d • Patent-pending “flow shaper” design provides the ultimate combination of low flows and starting pressures • Larger K-Factor provides lowest starting pressure in NFPA 13 applications (0.1 density)
1.01 (14.6) 1.10 (16.0) N/A N/A
N/A N/A N/A N/A
102-152mm down from ceiling 102-305m down from ceiling
Room Size m/ft
Flow lpm/gpm
Pressure bar/psi
Flow lpm/gpm
Pressure bar/psi
Down the slope up to 9.5° (2/12) 3.7 x 3.7 (12 x 12) 4.3 x 4.3 (14 x 14) 4.9 x 4.9 (16 x 16) 4.9 x 5.5 (16 x 18) 4.9 x 6.1 (16 x 20) 4.9 x 6.71 (16 x 22) 5.5 x 5.5 (18 x 18) 5.5 x 6.1 (18 x 20) 6.1 x 6.1 (20 x 20) 4.9 x 7.3 (16 x 24) 4.3 x 7.9 (14 x 26) 1
61 (16) 61 (16) 76 (20) 83 (22) 98 (26) 117 (31) 87 (23) 110 (29) 114 (30) 144 (38) 159 (42)
0.52 (7.6) 0.52 (7.6) 0.82 (11.9) 0.99 (14.4) 1.39 (20.1) 1.97 (28.6) 1.10 (15.7) 1.70 (25.0) 1.80 (26.8) 2.96 (42.9) 3.62 (52.4)
61 (16) 68 (18) 91 (24) 102 (27) 121 (32) 140 (37) 110 (29) 133 (35) 136 (36) 159 (42) 174 (46)
0.52 (7.6) 0.67 (9.7) 1.27 (18.4) 1.49 (21.7) 2.10 (30.4) 2.81 (40.7) 1.70 (25.0) 2.51 (36.4) 2.66 (38.5) 3.62 (52.4) 4.34 (62.9)
Flows shown for 68°C (155°F); 79°C (175°F).
Installation & Removal Tools Mirage® Concealed Cover Installer Tool. Enables the installation of a flat concealed cover plate from the floor without the need to use a ladder. Two sizes available p/n 14412 regular diameter, p/n 14867 large diameter.
Cabinet Wrench & Sprinkler Cap Removal Tool Designed to install Viking Concealed Residential Sprinklers VK456, VK457 & VK474 from floor without the need for a ladder. Optional for the removal of Sprinkler Caps, p/n 13619
June 2010
Escutcheon Installer Tool Designed to install Viking Model E-1 Recessed and F-1 Adjustable Escutcheons from the floor without the need for a ladder, p/n 15166
Installation tools and a length of CPVC pipe (all sold separately)
www.vikinggroupinc.com
Flat Cover Plate Finishes Residential flat cover plates are available in nine standard finishes. Prices and lead times may vary. Flat cover plates are 70mm (2¾”) diameter.
Antique Brass
Brushed Copper
Brushed Chrome
Bright Brass
White
Ivory
Brushed Brass
Black
Polished Chrome
Custom Colours
available for cover plates and frame style sprinklers.*
Cover Plates
Tech Data Page 136a Standard (left) Part No. 13750 70mm (2¾” )
Square Part No. 15394 84mm (3-5/16”)
Domed Part No. 12207 80mm (3-1/8”)
Large Part No. 14934 Part No. 16207 (for VK480)
Recessed and Sloped Ceiling Escutcheons Tech Data Page Sprinkler 135a
• E-1 Slip-On (Part No. 11123, 06419A, 06420A • E-2 Threaded (Part No. 11038, 11625 • F-2 Adjustable (Part No. 06911A, 06912A) (Refer to sprinkler datasheet for approved escutcheons)
G-1 Sloped (p/n 14315), Slip-On The Model G-1 Recessed Escutcheon allows horizontal sidewall sprinklers to be recessed up to 12.7 mm (½”) for sloped ceiling applications with ceilings sloped up to a maximum of 33.7° (8/12)
Special Painted Cover Plates and Frame Style Sprinklers *Special order only. Additional charges will apply. Orders covering special painted products are not subject to cancellation except by written permission and then only upon agreement to make payment for work already performed. Viking reserves the right to over ship special painted products produced in excess of order quantity at no charge. No return of these products is allowed. Changes to products may result in the loss of listings or approvals. For systems designed to NFPA 13D and 13R, or designed to NFPA 13 prior to 1999 Edition: Apply the listed areas of coverage and minimum water supply requirements shown in the most recent data sheet. For systems designed to the 1999 and 2002 editions of NFPA 13: The minimum required discharge from each of the design sprinklers is to be the greater of the following: • The flow rates given in the appropriate data page for NFPA 13D and 13R applications for each listed maximum area of coverage; or • A minimum discharge of 0.1 gpm/sq. ft. over the “design area” for each of the design sprinklers. NOTE: The As = S x L method must be used to determine the sprinkler protection area of coverage. See 2002 NFPA 13 paragraphs 8.5.2.1 and 11.2.3.5 (2). All data pages showing complete details of listings are available on the Viking web site at www.vikinggroupinc.com. In some cases, Sprinkler Identification Numbers may apply to more than one sprinkler. Please use part numbers when placing orders.
www.vikinggroupinc.com
June 2010
CPVC Pipe, Fittings and Accessories CPVC Pipe Manufactured by Viking Plastics Size
Part Number
DN20
34PIPE10
DN25
1PIPE10
DN32
114PIPE10
DN40
112PIPE10
DN50
2PIPE10
DN65
212PIPE10
DN80
3PIPE10
BlazeMaster® CPVC fittings are manufactured/supplied for Viking SupplyNet by NIBCO, Inc.
CPVC Standard Fittings Tee
Reducing Tee
Test Plug
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5011-007
250
DN25
V5011-010
100
2”
V5011-020
2
DN32
V5011-012
25
2-1/2”
V5011-025
1
DN40
V5011-015
25
3”
V5011-030
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20 x DN20 x DN25
V5011R-102
10
DN25 x DN20 x DN20
V5011R-125
100
DN40 x DN40 x DN32
V5011R-212
5
DN25 x DN20 x DN25
V5011R-126
10
DN40 x DN40 x DN50
V5011R-213
5
DN25 x DN25 x DN20
V5011R-131
100
DN50 x DN50 x DN20
V5011R-248
2
DN32 x DN25 x DN20
V5011R-157
5
DN50 x DN50 x DN25
V5011R-249
10
DN32 x DN25 x DN25
Tee (continued)
Reducing Tees (continued)
V5011R-158
25
DN50 x DN50 x DN32
V5011R-250
2
DN32 x DN25 x DN32
V5011R-159
5
DN50 x DN50 x DN40
V5011R-251
2
DN32 x DN32 x DN20
V5011R-167
25
DN65 x DN65 x DN25
V5011R-289
1
DN32 x DN32 x DN25
V5011R-168
25
DN65 x DN65 x DN32
V5011R-290
1
DN32 x DN32 x DN40
V5011R-169
5
DN65 x DN65 x DN40
V5011R-291
1
DN40 x DN32 x DN20
V5011R-201
5
DN65 x DN65 x DN50
V5011R-292
1
DN40 x DN32 x DN25
V5011R-202
5
DN80 x DN80 x DN40
V5011R-337
1
DN40 x DN40 x DN20
V5011R-210
25
DN80 x DN80 x DN50
V5011R-338
1
DN40 x DN40 x DN25
V5011R-211
25
DN80 x DN80 x DN65
V5011R-339
1
Size
Part Number
Box Qty.
DN15
V450-005
50
‘Refer to manufacturers datasheets and design manual for technical specifications, approval information and installation instructions’ June 2010
www.vikinggroupinc.com
90° Elbow
45° Elbow
Cross
Coupling
Reducing Coupling
Bushing
Cap
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5007-007
250
DN25
V5007-010
100
DN32
V5007-012
25
DN80
V5007-030
1
DN40
V5007-015
25
DN25 x DN20
V5007R-131
100
DN50
V5007-020
10
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5006-007
250
DN25
V5006-010
100
DN50
V5006-020
2
DN32
V5006-012
5
DN65
V5006-025
1
DN40
V5006-015
5
DN80
V5006-030
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5035-007
10
DN25
V5035-010
100
DN32
V5035-012
90° Elbow (continued) V5007-025
DN65
1
45° Elbow (continued)
Cross (continued) 4
DN65
V5035-025
5
DN80
V5035-030
1
DN25 x DN25 x DN32 x DN32
V5035R-131
10
Size
Part Number
Box Qty.
DN40
V5035-015
6
DN50
V5035-020
4
Size
Part Number
Box Qty.
DN20
V5001-007
250
DN25
V5001-010
100
DN50
V5001-020
10
DN32
V5001-012
25
DN65
V5001-025
1
DN40
V5001-015
25
DN80
V5001-030
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN25 x DN20
V5001R-131
10
DN32 x DN25
V5001R-168
5
DN40 x DN32
V5001R-212
5
DN40 x DN20
V5001R-210
5
DN50 x DN25
V5001R-249
2
DN40 x DN25
V5001R-211
5
DN50 x DN40
V5001R-251
2
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN25 x DN20
V5018-131
100
DN32 x DN20
V5018-167
25
DN50 x DN32
DN32 x DN25
Coupling (continued)
Reducing Coupling (continued)
Bushing (continued) V5018-250
2
V5018-168
25
DN50 x DN40
V5018-251
2
DN40 x DN20
V5018-210
5
DN65 x DN32
V5018-290
1
DN40 x DN25
V5018-211
25
DN65 x DN40
V5018-291
1
DN40 x DN32
V5018-212
25
DN65 x DN50
V5018-292
1
DN50 x DN20
V5018-248
2
DN80 x DN50
V5018-338
1
DN50 x DN25
V5018-249
2
DN80 x DN65
V5018-339
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5017-007
250
DN25
V5017-010
100
DN50
V5017-020
2
DN32
V5017-012
5
DN65
V5017-025
1
DN40
V5017-015
5
DN80
V5017-030
1
Cap (continued)
‘Refer to manufacturers datasheets and design manual for technical specifications, approval information and installation instructions’ www.vikinggroupinc.com
June 2010
CPVC Sprinkler Head Adapters Female Sprinkler Head Adapter with Metal Thread Insert
Size
Part Number
Box Qty.
DN20 x DN15
V5003SBI-101
100
DN25 x DN15
V5003SBI-130
50
DN25 x DN20
V5003SBI-131
10
Size
Part Number
Box Qty.
DN20 x DN15
V50032SBI-101
100
DN25 x DN15
V50032SBI-130
50
Size
Part Number
Box Qty.
DN20 x DN15
V50073SBI-101
100
DN25 x DN15
V50073SBI-130
50
DN25 x DN20
V50073SBI-131
10
DN32 x DN15
V50073SBI-166
5
Size
Part Number
Box Qty.
DN25 x DN25 x DN25
V5012SBI-010
50
Sprinkler Head Tee w/Metal Thread Inserts (continued)
DN20 x DN20 x DN15
V5012SBI-101
10
DN25 x DN20 x DN15
V5012RSBI-124
10
DN25 x DN25 x DN15
V5012SBI-130
50
DN32 x DN25 x DN15
V5012RSBI-156
5
DN32 x DN32 x DN15
V5012SBI-166
5
DN40 x DN32 x DN15
V5012RSBI-199
5
DN40 x DN40 x DN15
V5012SBI-209
5
DN50 x DN40 x DN15
V5012RSBI-237
2
DN50 x DN50 x DN15
V5012SBI-247
2
DN25 x DN15 x DN25*
V5014RSBI-122*
10
Part Number
Box Qty.
Spigot Female Sprinkler Head Adapter with Metal Thread Insert
Sprinkler Head 90 with Metal Thread Insert
Sprinkler Head Tee with Metal Thread Insert
Size
Part Number
Box Qty.
*Socket x FNPT x Socket Sprinkler Head Back to Back Cross with Metal Thread Insert
Back to Back Tee with Metal Threads Insert
Size
Part Number
Box Qty.
DN25 x DN25 x DN15 x DN15 1-1/8”
V50283SBIS-130
1
DN25 x DN25 x DN15 x DN15 1-15/16”
V50283SBIL-130
1
Size
Part Number
Box Qty.
DN15 x DN15 x DN25 1-1/8”
V501133SBIS-075
48
DN15 x DN15 x DN25 1-15/16” V501133SBIL-075
48
CPVC Transition Fittings Female Adapter with Metal Thread Insert
Spigot Female Adapter with Metal Thread Insert
Size
Size
Part Number
Box Qty.
DN20
V5003BI-007
10
DN25
V5003BI-010
50
DN40
V5003B1-015
5
DN32
V5003BI-012
5
DN50
V5003B1-020
2
Size
Part Number
Box Qty.
DN20
V50032BI-007
10
DN25
V50032BI-010
10
Female Adapter w/Metal Thread Inserts (continued)
‘Refer to manufacturers datasheets and design manual for technical specifications, approval information and installation instructions’ June 2010
www.vikinggroupinc.com
Male Adapter with Metal Thread Insert
Grooved Coupling Adapter
Standard Union
Transition Union with Metal Thread Insert
Flange - Solid
Blind Flange - Solid
Flange - Van Stone with Socket
Flange - Van Stone with Spigot
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5004BI-007
10
DN25
V5004BI-010
10
DN40
V5004BI-015
5
DN32
V5004BI-012
5
DN50
V5004BI-020
2
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN32
V5001G-012
30
DN40
V5001G-015
25
DN65 / 76mm
V5001G-065
10
DN50
V5001G-020
15
DN80
V5001G-030
8
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5033E-007
1
DN25
V5033E-010
1
DN50
V5033E-020
1
DN32
V5033E-012
1
DN65
V5033E-025
1
DN40
V5033E-015
1
DN80
V5033E-030
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5033E3-007
1
DN25
V5033E3-010
1
DN50
V5033E3-020
1
DN32
V5033E3-012
1
DN80
V5033E3-030
1
DN40
V5033E3-015
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5051H-007
1
DN25
V5051H-010
1
DN50
V5051H-020
1
DN32
V5051H-012
1
DN65
V5051H-025
1
DN40
V5051H-015
1
DN80
V5051H-030
1
Size
Part Number
Box Qty.
Size
Part Number
Box Qty.
DN20
V5019H-007
1
DN25
V5019H-010
1
DN50
V5019H-020
1
DN32
V5019H-012
1
DN65
V5019H-025
1
DN40
V5019H-015
1
DN80
V5019H-030
1
Size
Part Number
Box Qty.
DN80
V5051A-030
1
Size
Part Number
Box Qty.
DN80
V50512A-030
1
Male Adapter w/Metal Thread Inserts (continued)
Grooved Coupling Adapter (continued)
Standard Union (continued)
Transition Union w/Metal Thread Inserts (continued)
Flange - Solid (continued)
Blind Flange - Solid (continued)
‘Refer to manufacturers datasheets and design manual for technical specifications, approval information and installation instructions’ www.vikinggroupinc.com
June 2010
Waterflow Switches for CPVC Pipe Standard Glued - VSR-SFG Size
Part Number
DN25 / 1” DN32 / 1¼” DN40 / 1½” DN50 / 1”
VSR-SFG
Size
Part Number
DN25 / 1” DN32 / 1¼” DN40 / 1½” DN50 / 1”
VSR-SFT
Size
Part Number
DN50 / 2”
VSRF0200
Standard Threaded - VSR-SFT
Clamped - VSR
DN65 / 2½”
VSRF0250
DN80 / 3”
VSRF0300
Tools for CPVC Pipe Wheel Cutter (Quick Release)
Includes one spare wheel in knob Minimum Pipe Size
Maximum Pipe Size
Part Number
10 mm
63 mm
31647
25 mm
75 mm
36592
50 mm
110 mm
31657
Minimum Pipe Size
Maximum Pipe Size
Part Number
32 mm
100 mm
04430
40 mm
76 mm
64962
100 mm
100 mm
64967
Minimum Pipe Size
Maximum Pipe Size
Part Number
6 mm
36 mm
29993
12 mm
54 mm
20101
Minimum Pipe Size
Maximum Pipe Size
Part Number
DN20 / ¾”
DN80 / 3”
02247
Minimum Pipe Size
Maximum Pipe Size
Part Number
DN20 / ¾”
DN100 / 4”
04452
Deburrer (Internal / External)
Reamers (Internal & External)
Strap Clamp
Chain Vise
June 2010
www.vikinggroupinc.com
Hangers & Pipe Clamps for CPVC Pipe Hanger/Restrainer “Stand-Off”
Size
Part Number
Box Qty.
DN20 / ¾”
597811
100
DN25 / 1”
597812
100
DN32 / 1¼”
597813
100
DN40 / 1½”
597814
100
DN50 / 2”
597815
100
Size
Part Number
Box Qty.
DN20 / ¾”
597827
100
DN25 / 1”
597828
100
DN32 / 1¼”
597829
100
DN40 / 1½”
597831
100
DN50 / 2”
597832
100
Size
Part Number
Box Qty.
DN20 / ¾”
597822
100
DN25 / 1”
597823
100
DN32 / 1¼”
597824
100
DN40 / 1½”
597825
100
DN50 / 2”
597826
100
Size
Part Number
Box Qty.
DN20 / ¾”
597816
100
DN25 / 1”
597817
100
DN32 / 1¼”
597818
100
DN40 / 1½”
597819
100
DN50 / 2”
597821
100
Hanger/Restrainer 109
Hanger/Restrainer 108
Hanger/Restrainer 107
Loop Hanger Model FCN112
Size
Thread
Part Number
Box Qty.
Size
Thread
Part Number
Box Qty.
DN15 / ½”
M10
297860
100
DN65 / 2½”
M10
297920*
100
DN20 / ¾”
M10
297870
100
DN80 / 3”
M10
297930
50
DN25 / 1”
M10
297880
100
DN100 / 4”
M10
297940
50
DN32 / 1¼”
M10
297890
100
DN125 / 5”
M12
297950
25
DN40 / 1½”
M10
297900
100
DN150 / 6”
M12
297960**
20
DN50 / 2”
M10
297910
100
DN200 / 8”
M12
297970
15
The FCN112 has a unique design that allows the hanger to be used with both CPVC and steel pipes. * Suitbale for 73.0 mm & 76.1 mm ** Suitable for 165 mm & 168 mm
Pipe Clamp with Insulation 240 Easy one-hand installation
www.vikinggroupinc.com
Size
Part Number
Box Qty.
DN20 / ¾”
400081
100
DN25 / 1”
400082
75
DN32 / 1¼”
400083
50
DN40 / 1½”
400085
50
DN50 / 2”
400086
50
June 2010
Accessories for CPVC Pipe FP-1000 One-Step Cement Size
Part Number
473 ml / 1 US Pint
V5097P
946 ml / 1 US Quart
V5097Q
25 mm Brush Cap Size
Part Number
25 mm / 1”
V5096
Size
Part Number
20 mm / ¾”
V5093-S
20 mm Dauber
37 mm Dauber Cap Size
Part Number
37 mm / 1½”
V5093-L
Size
Part Number
75 mm / 3”
V5097
Size
Part Number
300ml Tube
P35860-323
75 mm Roller
“Caulk&Walk” Firestopping Sealant for CPVC Piping
June 2010
www.vikinggroupinc.com
SupplyNet
速
Viking SupplyNet Ltd. G6 Bellwin House Bellwin Drive Flixborough Industrial Estate Flixborough Scunthorpe North Lincolnshire DN15 8SN Tel.: 01724 295 300 Fax: 01724 295 301 E-mail: vikinguk@vikingcorp.com Web: www.vikinggroupinc.com