2 minute read

SHOPES

PUBLIC/PRIVATE SPACE

OF ALL THE THINGS CONSIDERED WHEN DESIGNING, WHETHER ARCHITECTURE OR CITY PLANNING, AMONG THE MOST IMPORTANT ARE PRIVATE AND PUBLIC SPACE, AND THE TRANSITION BETWEEN THE TWO. THERE ARE TIMES WHEN THE NEED IS OBVIOUS, PRIVATE SPACE IN A RESIDENCE FOR INSTANCE, AND OTHER TIMES WHEN IT'S MORE AMBIGUOUS, SUCH AS IN THE CASE OF PRIVATELY OWNED PUBLIC SPACES WHERE WHO THE "PUBLIC" IS CAN BE WIDELY INTERPRETED. THE MOVE BETWEEN PRIVATE AND PUBLIC SPACES CAN ALSO VARY FROM A WELL DEFINED BOUNDARY TO A MORE LOOSE TRANSITION. THESE AMBIGUITIES ARE INCREASING ESPECIALLY IN THIS TIME OF INCREASED CONNECTIVITY.

Advertisement

CONSIDERATIONS

• THE WIDTH OF THE FRONT AND REAR SETBACK, IF LEFT AT ANY POINT OF THE BUILDING,

SHALL NOT BE EQUAL TO ONE FOURTH OF THE HEIGHT OF THE BUILDING (MINIMUM 2M)

AND THE WIDTH OF THE SIDE BACK IF LEFT AT ANY POINT OF THE BUILDING SHALL BE EQUAL

TO ONE FIFTH OF THE HEIGHT OF THE BUILDING ( MINIMUM 1.5 M). • DWELLING UNIT DENSITY: - PERMISSIBLE DWELLING UNIT DENSITY FOR NEW/UNDEVELOPED

AREAS IS 330 UNITS/HA. (CLAUSE NO. 3.3.6 OF GROUP HOUSING. SUB CLAUSE NO. VI). • PARKING SHALL NOT BE COVERED FROM THREE SIDES OTHERWISE IT WILL BE COUNTED IN

FAR SO THIRD SIDE CAN BE SEMI COVERED WITH JALIS TO PROVIDE MORE PROTECTION

• THE TOTAL AREA UNDER PARKING IS NOT TO BE LESS THAN 10% OF THE AREA OF THE SITE

PLUS 10% OF THE AREA OF THE COVERED AREA ON ALL THE FLOORS . EVERY BUILDING

SHOULD HAVE A EMERGENCY FIRE EXIT STAIR CASE .

• TURNING RADIUS OF ROADS: - MINIMUM 4.5M TURNING RADIUS WILL BE REQUIRED FOR 18M ROADS. (CLAUSE NO. 2.3.3 OF ROAD/PATHWAYS AND CYCLE TRACKS. SUB CLAUSE NO.

IV). BLOCK LENGTH: - MAXIMUM LENGTH OF THE BLOCK WILL BE 200M (CLAUSE NO. 2.3.4 OF

ROAD PATHWAYS AND CYCLE TRACKS).

• DIMENSION RISER 250MMTREAD 150MMWIDTH 1250MM • ACCORDING TO LUCKNOW BUILDING BYE LAWS (AMENDED 2011/2016)> FLOOR AREA RATIO:

MAXIMUM PERMISSIBLE F.A.R. FOR NEW/UNDEVELOPED AREAS IS 2.5. (CLAUSE NO. 3.3.6 OF

GROUP HOUSING. SUB CLAUSE NO. III). • REFUGE AREA SHOULD BE GIVEN IN EVERY BUILDING IN FIRE STAIR CASE.

• MAXIMUM 4% OF HABITABLE FLOOR AREA IS TAKEN. MINIMUM AREA SHOULD BE TAKEN 15SQ.M 1SQ.M PER PERSON SHOULD BE TAKEN

• IF THE BALCONY WIDTH IS 1500MM THEN IT WILL NOT INCLUDE IN F.A.R. • THE STILT FLOOR HEIGHT MINIMUM IS 240MM.STILT FLOOR SHOULD BE OPEN MINIMUM

FROM 3SIDE .

• GROUND COVERAGE: - MAXIMUM PERMISSIBLE GROUND COVERAGE IS 40% OF THE

TOTALSITE AREA. (CLAUSE NO. 3.3.6 OF GROUP HOUSING, SUB CLAUSE NO. 1). • SET BACK: - REQUIRED SET BACK FOR MORE THAN 55 M BUILDINGS IS 16 M FROM ALL

FOURSIDES OF THE SITE. (CLAUSE NO. 3.4.5 OF SET BACK, SUB CLAUSE NO. 1).THE MAXIMUM

AREA FOR THE GUARD ROOM IS 1.5SQ.M.

This article is from: