CP TOOLBOX PORTABLE CATHODIC PROTECTION TEST RECTIFIER
POWERFUL PORTABLE CATHODIC PROTECTION POWER SUPPLY The CP Toolbox is a rugged air cooled rectifier used as a portable cathodic protection power supply in a variety of testing scenarios. The system is very powerful and lightweight, providing up to 50 volts and 50 amps maximum DC output for under 25 pounds. A digital interrupt allows for easy user control of On and Off time settings.
Features: • Portable Power DC output up to 50 volts and 50 amps of on-site power • Under 25 Pounds! CP Toolbox utilizes advanced Switch-mode Converter Technology to provide a lightweight portable test rectifier weighing in at under 25 pounds • Rugged and Durable This case is ideal for transporting test equipment with a comfortable carrying handle and padlock feature to lock the case while testing • Compact Design 22” Length x 9” Height x 14” Width • Output Interruption Advanced control for output interruption provides the user with unlimited On and Off time configurations • Test Points Current and voltage measurement points provided on the front panel • LED Displays Easily visible LED displays, even when used in direct sunlight
@copyright 2015, Astrodyne, Inc
www.AstrodyneTDI.com | +1 908-850-5088
This document is believed to be correct at time of publication and Astrodyne, Inc accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice
CP TOOLBOX PORTABLE CATHODIC PROTECTION TEST RECTIFIER
Specifications AC INPUT Input Voltage
90VAC-132VAC (Line to Line or Line to Neutral)
Input Cable
C20 IEC Inlet with a 8ft 120VAC 20A power cord (included)
Input Current
20A max
Efficiency
Greater than 90% at nominal operation
DC Output Output Voltage
0 -50V
Output Current
0 -50A, adjustable
Output Power
2,000W max
MECHANICAL Case Dimensions
L22in x W14in x H9in
Weight
Less than 25 lbs
Padlock Feature
Yes, designed into case
Transport Vibration
MIL-STD-810G
USER INTERFACE PANEL Digital Displays
Output voltage and current visible in direct sunlight on LED displays
Test Points
Precision test points provides for shunt measurements
21.90
13.98
ALARMS AND CONTROL Interrupt Timer
The user can set an adjustable timer which will interrupt the output with user-defined on and off times
On & Off range
Both On & Off settings range from 1.0 second to 60 minutes
Fault LEDs
LEDs show the state of the output as enabled, disabled, or in fault
9.00
PROTECTION FEATURES Output Over-Voltage
Output protected with over-voltage shutdown circuitry
Output Over-Current
Internally fused
Over-Temperature
Internal thermostat shuts down unit if temperatures exceed safe
ENVIRONMENTAL CONDITIONS Cooling
Air cooled
Operational Temperature
-20 to 55째C in a semi-sheltered environment, not directly subjected to rain
Storage Temperature
-40째C to +85째C