DYNALOAD® Air Cooled Electronic Loads

THE XBL® GEN2 ADVANTAGE Testing Tomorrow’s Power Today

TDI POWER DEMANDING APPLICATIONS DEMAND TDI POWER


OVERVIEW DYNALOAD® XBL® GEN2 SERIES To meet industry demands, DYNALOAD has developed a new line of electronic loads that offer cutting-edge functionality at a competitive price. The XBL series is a reliable, precision controlled, high speed load for fuel cell testing, power supply testing, battery testing and custom applications.

6000 W MODEL 4000 W MODEL

(ALSO AVAILABLE IN BLACK)

The XBL® DYNALOAD® Series features 800, 2000, 4000, and 6000 Watt models with wide range voltage inputs and sophisticated computer programming via GPIB, Ethernet, or RS232. These units feature an integrated web page for local system operation and control.

GRAPHIC USER INTERFACE 2000 W MODEL

800 W MODEL

Individual models are available for specialized low voltage or high current applications (models up to 1000 amps are available). All models include easy to apply master slave parallel capabilities and closed box calibration. Higher power models incorporate variable speed forced air cooling to asure a quiet environment.

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


FEATURES & BENEFITS • Programmable Microprocessor smart control -16 bit A/D and D/A architecture for superior control and resolution • True Compatibility of GPIB commands to its predecessor the RBL Series • Fast Response Master/Slave Communications via reliable CANbus and Auto-Sync makes mating and load balancing seamless • AutoHunt in CP and CR mode, automatically compensates for cable IR drop until power matches the selected value - with no operator involvement

• Ultra-Low compliance voltage (0.3V) even at 1000A! (50V models), additional loads can reduce this voltage further • Three Full Scale Voltage and Three Full Scale Current Ranges • More standard interfaces: Ethernet (LAN), GBIB/ IEEE488 and RS-232 • ATE friendly with LabVIEW drivers and SCPI Command Set • Front Panel Lockout (remote or local)

• High Accuracy Pulse mode for all modes of operation: CC, CV, CP and CR

• Three methods of Remote Control - Ethernet or GPIB (TCP, Web Browser* or Virtual Front Panel Application)

• Programmable Slew Rates with high speed and accuracy • Intuitive front panel controls with acceleration mode encoder offers quick set point control and ease of use

• XM Plus Command enables sinusoidal signal injection for impedance characterization • Current Interrupt Feature

• Closed Box Calibration for end user calibration saves money, limits downtime

• Master and Slave Functionality enables single rack system size upwards to 36KW.

• Individual FET protection - isolates power stages • 0 – 10Vdc External Analog Programmable • OV, OC, OP and OT fast self protection safeguards the unit for enhanced reliability

6000 W MODEL 4000 W MODEL

2000 W MODEL

800 W MODEL

(ALSO AVAILABLE IN BLACK)

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


SPECIFICATIONS OPERATING MODES Constant Current: 0 to selected full scale current Prog. Accuracy: 0.1% of setpoint ±5ma Resolution: .0015% of selected full scale

COMMUNICATION READ-BACK Current: Resolution: .0015% of selected full scale Accuracy: 0.1% ± 10ma

Constant Resistance: Constant Resistance mode operates in Amps/Volt, units entered in ohms or A/V Prog. Accuracy: 1% of setpoint Resolution: .0015% of selected full scale

Voltage: Resolution: .0015% of selected full scale Accuracy: 1% ± 10mV

Constant Voltage: 0 to selected selected full scale Prog. Accuracy: 1% of setpoint +- 250mv Resolution: .0015% of selected full scale Constant Power: 0 to full scale power Prog. Accuracy: 1% of setpoint +-2W Resolution: .0015% of full scale power ANALOG MODE External Prog: 0 to 10 Volts input yields 0 to selected full scale current Input Impedance: 330k Ohms PULSE MODE Frequency: 0.1Hz to 10kHz Duty Cycle: 0 - 100% Minimum Pulse Width: 150μsec Adjustable Slew Rate: 10μsec to 0.4 sec OUTPUT SIGNALS Current Sample Output: Scaling:10 Volts = selected full scale Accuracy:±0.5% of selected full scale ±10mV

Power: Resolution: .0015% of selected full scale Accuracy: 1% ± 2W Communication Modes: IEEE 4888 RS 232 Ethernet (HTTP, TCP, & Telnet) MISCELLANEOUS AC Input: User Selectable 100VAC, 120VAC, 200VAC, 240VAC, ±10%, 48 - 62 Hz @ 350W (2000W, 4000W, and 6000W models) User selectable 120VAC, 240VAC, ±10%, 48 - 62Hz @ 350W (800W model) Ambient Temp: 0°C to 40°C Weight: 800W: 26lbs. (39.0kg) 2000W: 59lbs. (26.8kg) 4000W: 86lbs. (39.0kg) 6000W: 112lbs. (50.8kg)

PROTECTION Current Limit: Range: 0-105% of selected full scale Resolution: 0.4% of selected full scale Voltage Limit: Range: 0-105% of selected full scale Resolution: 0.4% of selected full scale Power Limit: 800W Range: 0-840 Watts 2000W Range: 0-2100 Watts 4000W Range: 0-4200 Watts 6000W Range: 0-6300 Watts Thermal: Load disconnect at internal temperature of 90°C Under voltage: Range: Programmable 0-full range (default OV) Resolution: 0-4% of selected full scale

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


SAFE OPERATING AREA & SPECIFICATIONS 800W XBL 50-150-800 AIR

XBL-100-120-800-AIR

OPERATING RANGES (FULL SCALES)

OPERATING RANGES (FULL SCALES)

Voltage: Current: Power: Short Circuit:

CONSTANT RESISTANCE RANGES Range: 10V 20V 50V

2A 0.1 0.05 0.02

High Ohms Mode: 20A 150A 1.0 7.5 0.5 3.75 0.2 1.5

Low Ohms Mode: A/V 2A 20A 150A 1.0 10.0 75.0 0.5 5.0 37.5 0.2 2.0 15.0

Range: 10V 50V 100V

2A 0.1 0.02 0.01

High Ohms Mode: 20A 120A 1.0 6.0 0.2 1.2 0.1 0.6

100

100

VOLTS

1000

10

10

1

1

0.1

0.1

1

10

100

1000

0.1

1

10

XBL 400-120-800 AIR

1000

XBL 600-40-800 AIR

OPERATING RANGES (FULL SCALES)

OPERATING RANGES (FULL SCALES)

Voltage: Current: Power: Short Circuit:

Voltage: Current: Power: Short Circuit:

20 Volts, 200 Volts, 400 Volts 2 Amps, 20 Amps, 120 Amps 800 Watts 0.03 Ohms max.

CONSTANT RESISTANCE RANGES

20 Volts, 200 Volts, 600 Volts 2 Amps, 20 Amps, 40 Amps 800 Watts 0.10 Ohms max.

CONSTANT RESISTANCE RANGES

High Ohms Mode: Range: 2A 20A 120A 20V 0.05 0.5 3.0 200V 0.005 0.05 0.3 400V 0.0025 0.025 0.15

Low Ohms Mode: A/V 2A 20A 120A 0.5 5.0 30.0 0.05 0.5 3.0 0.025 0.25 1.5

INPUT CHARACTERISTICS

High Ohms Mode: Range: 2A 20A 40A 20V 0.05 0.5 1.0 200V 0.005 0.05 0.1 600V 0.001667 0.001667 0.03333

Low Ohms Mode: A/V 2A 20A 40A 0.5 5.0 10.0 0.05 0.5 1.0 0.01667 0.166667 .333333

INPUT CHARACTERISTICS

1000

1000

100

100

VOLTS

VOLTS

100

AMPERES

AMPERES

10

10

1

1

0.1

Low Ohms Mode: A/V 2A 20A 120A 1.0 10.0 60.0 0.2 2.0 12.0 0.1 1.0 6.0

INPUT CHARACTERISTICS

1000

0.1

10 Volts, 50 Volts, 100 Volts 2 Amps, 20 Amps, 120 Amps 800 Watts 0.008 Ohms max.

CONSTANT RESISTANCE RANGES

INPUT CHARACTERISTICS

VOLTS

Voltage: Current: Power: Short Circuit:

10 Volts, 20 Volts, 50 Volts 2 Amps, 20 Amps, 150 Amps 800 Watts 0.004 Ohms max.

0.1

0.1

1

10

100

1000

0.1

AMPERES

1

10

100

1000

AMPERES

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


SAFE OPERATING AREA & SPECIFICATIONS 2000W XBL 50-400-2000 AIR

XBL 100-300-2000 AIR

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

OPERATING RANGES (FULL SCALES)

CONSTANT RESISTANCE RANGES Range: 10V 20V 50V

20A 1.0 0.5 0.2

High Ohms Mode: 200A 400A 10.0 20.0 5.0 10.0 2.0 4.0

Low Ohms Mode: A/V 20A 200A 400A 10.0 100.0 200.0 5.0 50.0 100.0 2.0 20.0 40.0

Range: 10V 50V 100V

20A 1.0 0.2 0.1

100

100

VOLTS

1000

10

1

0.1

1

10 AMPERES

100

0.1

1

10

100

1000

AMPERES

XBL 600-100-2000 AIR

Voltage: Current: Power: Short Circuit:

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

20 Volts, 200 Volts, 400 Volts 20 Amps, 200 Amps, 300 Amps 2000 Watts 0.013 Ohms max.

CONSTANT RESISTANCE RANGES

20 Volts, 200 Volts, 600 Volts 2 Amps, 20 Amps, 100 Amps 2000 Watts 0.04 Ohms max.

CONSTANT RESISTANCE RANGES

High Ohms Mode: 20A 200A 300A 0.5 5.0 7.5 0.05 0.5 0.75 0.025 0.25 0.375

Low Ohms Mode: A/V 20A 200A 300A 5.0 50.0 75.0 0.5 2.5 7.5 0.25 2.5 3.75

INPUT CHARACTERISTICS

High Ohms Mode: Low Ohms Mode: A/V Range: 2A 20A 100A 2A 20A 100A 20V 0.05 0.5 2.5 0.5 5.0 25.0 200V 0.005 0.05 0.25 0.05 0.5 2.5 600V 0.001667 0.016667 0.083333 0101667 0.166667 0.83333

INPUT CHARACTERISTICS

1000

1000

100

100

VOLTS

VOLTS

10

0.1

1000

OPERATING RANGES (FULL SCALES)

10

1

0.1

Low Ohms Mode: A/V 20A 200A 300A 10.0 100.0 150.0 2.0 20.0 30.0 1.0 10.0 15.0

1

XBL 400-300-2000 AIR

Range: 20V 200V 400V

High Ohms Mode: 200A 300A 10.0 15.0 2.0 3.0 1.0 1.5

INPUT CHARACTERISTICS

1000

0.1

10 Volts, 50 Volts, 100 Volts 20 Amps, 200 Amps, 300 Amps 2000 Watts 0.003 Ohms max.

CONSTANT RESISTANCE RANGES

INPUT CHARACTERISTICS

VOLTS

Voltage: Current: Power: Short Circuit:

10 Volts, 20 Volts, 50 Volts 20 Amps, 200 Amps, 400 Amps 2000 Watts 0.00075 Ohms max.

10

1

0.1

0.1

1

10 AMPERES

100

1000

0.1

1

10

100

1000

AMPERES

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


SAFE OPERATING AREA & SPECIFICATIONS 4000W XBL 50-1000-4000 AIR

XBL 100-600-4000 AIR

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

OPERATING RANGES (FULL SCALES)

CONSTANT RESISTANCE RANGES Range: 10V 20V 50V

Voltage: Current: Power: Short Circuit:

10 Volts, 20 Volts, 50 Volts 100 Amps, 500 Amps, 1000 Amps 4000 Watts 0.0004 Ohms max.

CONSTANT RESISTANCE RANGES

High Ohms Mode: 100A 500A 1000A 5.0 25.0 50.0 2.5 12.5 25.0 1.0 5.0 10.0

Low Ohms Mode: A/V 100A 500A 1000A 50.0 250.0 500.0 25.0 125.0 250.0 10.0 50.0 100.0

INPUT CHARACTERISTICS

Range: 10V 50V 100V

VOLTS

1

10

1

0.1

1

10

100

0.1

1000

AMPERES

1

10

100

1000

XBL 600-200-4000 AIR

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

0.1

AMPERES

XBL 400-600-4000 AIR

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

20 Volts, 200 Volts, 400 Volts 20 Amps, 200 Amps, 600 Amps 4000 Watts 0.0065 Ohms max.

CONSTANT RESISTANCE RANGES

20 Volts, 200 Volts, 600 Volts 2 Amps, 20 Amps, 200 Amps 4000 Watts 0.019 Ohms max.

CONSTANT RESISTANCE RANGES

High Ohms Mode: 20A 200A 600A 0.5 5.0 15.0 0.05 0.5 1.5 0.025 0.25 0.75

Low Ohms Mode: A/V 20A 200A 600A 5.0 50.0 150.0 0.5 2.5 15.0 0.25 2.5 7.5

INPUT CHARACTERISTICS

High Ohms Mode: Low Ohms Mode: A/V Range: 2A 20A 200A 2A 20A 200A 20V 0.05 0.5 5.0 0.5 5.0 50.0 200V 0.005 0.05 0.5 0.05 0.5 5.0 600V 0.001667 0.016667 0.166667 0.016667 0.166667 1.666667

INPUT CHARACTERISTICS 1000

1000

100

VOLTS

100

VOLTS

Low Ohms Mode: A/V 20A 200A 600A 10.0 100.0 300.0 2.0 20.0 60.0 1.0 10.0 30.0

100

10

10

10

1

1

0.1

High Ohms Mode: 200A 600A 10.0 30.0 2.0 6.0 1.0 3.0

1000

100

VOLTS

20A 1.0 0.2 0.1

INPUT CHARACTERISTICS

1000

Range: 20V 200V 400V

10 Volts, 50 Volts, 100 Volts 20 Amps, 200 Amps, 600 Amps 4000 Watts 0.0016 Ohms max.

0.1 0.1

1

10

100

1000

0.1

AMPERES

1

10

100

1000

AMPERES

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice

TDI POWER


SAFE OPERATING AREA & SPECIFICATIONS 6000W XBL 100-600-6000 AIR

XBL 400-600-6000 AIR

OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

OPERATING RANGES (FULL SCALES)

CONSTANT RESISTANCE RANGES Range: 10V 50V 100V

20A 1.0 0.2 0.1

20 Volts, 200 Volts, 400 Volts 20 Amps, 200 Amps, 600 Amps 6000 Watts 0.0065 Ohms max.

CONSTANT RESISTANCE RANGES

High Ohms Mode: 200A 600A 10.0 30.0 2.0 6.0 1.0 3.0

Low Ohms Mode: A/V 20A 200A 600A 10.0 100.0 300.0 2.0 20.0 60.0 1.0 10.0 30.0

INPUT CHARACTERISTICS

Range: 20V 200V 400V

High Ohms Mode: 20A 200A 600A 0.5 5.0 15.0 0.05 0.5 1.5 0.025 0.25 0.75

Low Ohms Mode: A/V 20A 200A 600A 5.0 50.0 150.0 0.5 5.0 15.0 0.25 2.5 7.5

INPUT CHARACTERISTICS

1000

1000

100

100

VOLTS

VOLTS

Voltage: Current: Power: Short Circuit:

10 Volts, 50 Volts, 100 Volts 20 Amps, 200 Amps, 600 Amps 6000 Watts 0.0016 Ohms max.

10

1

10

1

0.1

1

10

100

1000

0.1

0.1

AMPERES

1

10

100

1000

AMPERES

XBL 600-200-6000 AIR OPERATING RANGES (FULL SCALES) Voltage: Current: Power: Short Circuit:

20 Volts, 200 Volts, 600 Volts 2 Amps, 20 Amps, 200 Amps 6000 Watts 0.015 Ohms max.

CONSTANT RESISTANCE RANGES High Ohms Mode: Low Ohms Mode: A/V Range: 2A 20A 200A 2A 20A 200A 20V 0.05 0.5 5.0 0.5 5.0 50.0 200V 0.005 0.05 0.5 0.05 0.5 5.0 600V 0.001667 0.016667 0.166667 0.166667 0.166667 1.666667

INPUT CHARACTERISTICS 1000

VOLTS

100

10

1

0.1 0.1

1

10

100

1000

AMPERES

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 © Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice REV 5-3-2014

TDI POWER


OUTLINE DRAWINGS 800W OUTLINE

2000W OUTLINE

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 Š Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice REV 5-3-2014

TDI POWER


OUTLINE DRAWINGS 4000W OUTLINE

6000W OUTLINE

DEMANDING APPLICATIONS DEMAND TDIPOWER www.tdipower.com | +1 908-850-5088 Š Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice REV 5-3-2014

TDI POWER


ABOUT TDI POWER TDI Power is a leading, private manufacturer of highly reliable and technologically advanced electrical power solutions. Built on a 50 year history of engineering innovation, TDI is recognized as a market driven organization that focuses on our competitive strengths to meet our customers’ needs. Our diverse capabilities allow us to serve the automotive, military/aerospace, industrial, medical and test and measurement markets. Our commitment is to deliver high-end, problem solving solutions where and when needed. From our state-of-the-art shop floor manufacturing control system, to our philosophy of conservative design practices, TDI Power’s very structure is built around creating the highest possible quality products. Design Verification Testing, Highly Accelerated Life Testing (HALT), Highly Accelerated Stress Screening (HASS) and internal labs for solar and EMI testing add to our analytical capabilities and dedication to continuous improvement, higher reliability, and lower overall program costs.

TDIPower.com

Corporate Headquarters 36 Newburgh Rd. Hackettstown, NJ 07840 U.S.A. P: +1.908.850.5088 E: sales@tdipower.com

DEMANDING APPLICATIONS DEMAND TDI POWER www.tdipower.com

© Copyright 2014, Transistor Devices, Inc.

This document is believed to be correct at time of publication and Transistor Devices, Inc. accepts no responsibility for consequences from printing errors or inaccuracies. Specifications are subject to change without notice REV 5-3-2014

TDI POWER


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.