Product Catalog
ATEN NRGence™ Energy Intelligence PDU for Data Centers
2015
2016
Simply Better Connections
I
Our Vision “Simply Better Connections” has always been at the heart of the ATEN brand. It means providing innovative solutions for you to make better connections, efficiently and seamlessly, to the information that you value. As a result, ATEN connects you to the world, anytime and anywhere, by providing technologies that enable you to share and to care. ATEN makes professional and personal life easier and better connected.
About ATEN ATEN, established in 1979, specializes in connectivity management solutions for accessing and sharing technologies. ATEN consolidates all of its products under the ATEN brand to provide a standard of consistent service under one name. The ATEN brand consists of innovative solutions applied to IT infrastructure access management, professional audio/video, green energy products for consumers, small/home offices (SOHO), small to medium sized business (SMB) and enterprise customers. ATEN’s Altusen™ IT infrastructure access management solutions offer connectivity and control capabilities for SMB and Enterprise customers that allow people to effectively manage IT equipment from anywhere in the world. ATEN’s VanCryst™ professional audio/video solutions offer signal management and system control for home and professional audio/video installations with a variety of applications in corporate, education, government, hospitality and home theater environments. ATEN’s NRGence™ Green Energy line offers sensor-enabled energy-saving hardware and software solutions for the data center with a range of intelligent power and cooling distribution units that provide real-time energy management and performance indicators locally and remotely. ATEN specializes in connectivity and management solutions. We distribute our products through a global sales network to meet a broad range of customer needs. ATEN delivers with quality and we care about our customers. We are committed to the best customer support in the industry.
SOHO / SMB Solutions
Altusen
™
Enterprise Solutions
VanCryst
™
Professional A / V Solutions
NRGence
™
Green Energy Business
Consumer Electronics
KVM Switches
Over IP Solutions
AV & Digital Home
Control Center
Digital Media Matrix Solutions
Green Data Center
Cable KVM
Remote Energy Control
Computer Accessories
Desktop KVM
KVM over IP
Media Matrix Solutions
Indoor Air Quality
Mobility
Rack KVM
Serial Console Server
HVAC Balance System
Networking
LCD KVM
Power
Media Distribution Solutions
Smart Energy
KVM & KVMP
Video Matrix Switches
KVM Switches
Video Switches
Secure KVM
Matrix KVM
Video Splitters
USB Solutions
High-Density KVM
Video Extenders
Data Communications
Dual Rail LCD KVM
Video Converters
KVM Extenders
Resources Pipeline Distribution Note: IOGEAR brand is only available in North & South America and limited countries
Our Core Value Integrity
with pragmatism as our philosophy
Caring
with respect as our spirit
Ambition
with optimism as our attitude
Novelty
with added-value as our achievement
II
Contents PDUs for International Regions (IEC System) 01
Metered 1U PDU
PE5108G / PE5208G
03
Metered-Switched 1U PDU
PE6108G / PE6208G
05
Outlet-Metered 1U PDU
PE7108G / PE7208G
07
Outlet-Metered-Switched 1U PDU
PE8108G / PE8208G
09 00
Metered Ready PDU
PE1216G / PE1324G / PE1213G * / PE1316G * PE2220G * / PE2340G *
13
Metered PDU (16A)
PE5216G * / PE5220sG *
15
Metered PDU (32A)
PE5324G * / PE5324LG * PE5340sG / PE5340SLG * / PE5312sGL * / PE5312sGR *
19
Switched PDU
PE6216G / PE6324G / PE6324LG *
21
Outlet-Metered PDU
PE7214G * / PE7216G / PE7324G *
23
Outlet-Metered-Switched PDU
PE8216G / PE8316G * / PE8324G *
25
Outlet-Metered-Critical-Load PDU
PE9216G * / PE9222G * / PE9324G * / PE9330G *
Energy Monitoring Device 27
EC1000 / EC2004 *
Energy & DCIM Management Software 29
eco Sensors
Optional Accessories 33
Environment Sensors Mounting Kits Lok-U-Plug
* Products available on demand. Contact sales@aten.be for further information and the latest product availability schemes.
III
01
Metered 1U PDU
PE5108G / PE5208G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
PE5108G
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
PE5208G Outlet Switch Control •
Always On
Special Features • •
Lok-U-Plug – easily secures power cable to PDU 1U rack space
432.4
44
PE5108G
44
PE5208G
432.4
PDUs for International Regions (IEC System)
Specifications Model
PE5108G
PE5208G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
10A(Max)
16A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
2300 VA(Max)
3680 VA(Max)
Outlet Type
Total: 8 x IEC320 C13
Total: 7 x IEC320 C13 + 1 x IEC320 C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
10A(Max)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
10A(Max)
16A(Max)
Maximum Output Current (Total)
10A(Max)
16A(Max)
1 x 10A Non-Fuse Breaker
1 x 16A Non-Fuse Breaker
Breakers Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
None
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
43.24 x 4.40 x 21.93 cm
Shipping Dimensions ( H x W x D)
53 x 14 x 31 cm
Weight / Shipping Weight
2.82 / 5.6 kg
2.79 / 5.6 kg
Power Cord Length
3m
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE5108G
PE5208G
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
02
03
Metered-Switched 1U PDU
PE6108G / PE6208G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
PE6108G
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
PE6208G Outlet Switch Control Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power • Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order • •
Special Features Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices • Lok-U-Plug – easily secures power cable to PDU • 1U rack space •
44
PE6108G
44
PE6208G
432.4 mm
PDUs for International Regions (IEC System)
Specifications Model
PE6108G
PE6208G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
10A(Max)
16A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
2300 VA(Max)
3680 VA(Max)
Outlet Type
Total: 8 x IEC320 C13
Total: 7 x IEC320 C13 + 1 x IEC320 C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
10A(Max)
16A(Max)
Maximum Output Current (Total)
10A(Max)
16A(Max)
1 x 10A Non-Fuse Breaker
1 x 16A Non-Fuse Breaker
Breakers Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
Yes
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
43.24 x 4.40 x 21.93 cm
Shipping Dimensions ( H x W x D)
53 x 14 x 31 cm
Weight / Shipping Weight
2.82 / 5.6 kg
2.79 / 5.6 kg
Power Cord Length
3m
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, CE-LVD, GOST, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE6108G
PE6208G
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
04
05
Outlet-Metered 1U PDU
PE7108G / PE7208G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
PE7108G
Metering PDU and outlet level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
PE7208G Outlet Switch Control •
Always On
Special Features • •
Lok-U-Plug – easily secures power cable to PDU 1U rack space
432.4
44
PE7108G
44
PE7208G
432.4
PDUs for International Regions (IEC System)
Specifications Model
PE7108G
PE7208G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
10A(Max)
16A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
2300 VA(Max)
3680 VA(Max)
Outlet Type
Total: 8 x IEC320 C13
Total: 7 x IEC320 C13 + 1 x IEC320 C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
10A(Max)
16A(Max)
Maximum Output Current (Total)
10A(Max)
16A(Max)
1 x 10A Non-Fuse Breaker
1 x 16A Non-Fuse Breaker
Breakers Metering
Outlet Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
None
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
43.24 x 4.40 x 21.93 cm
Shipping Dimensions ( H x W x D)
53 x 14 x 31 cm
Weight / Shipping Weight
2.87 / 5.8 kg
Power Cord Length
3m
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE7108G
PE7208G
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
06
07
Outlet-Metered-Switched 1U PDU
PE8108G / PE8208G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
PE8108G
Metering PDU and outlet level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
PE8208G Outlet Switch Control Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups Outlet groups supported at the PDU level • Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power • Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order • •
Special Features Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices • Lok-U-Plug – easily secures power cable to PDU • 1U rack space •
44
PE8108G
44
PE8208G
432.4 mm
PDU for International Region (IEC System)
Specifications Model
PE8108G
PE8208G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
10A(Max)
16A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
2300 VA(Max)
3680 VA(Max)
Outlet Type
Total: 8 x IEC320 C13
Total: 7 x IEC320 C13 + 1 x IEC320 C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
10A(Max)
16A(Max)
Maximum Output Current (Total)
10A(Max)
16A(Max)
1 x 10A Non-Fuse Breaker
1 x 16A Non-Fuse Breaker
Breakers Metering
Outlet Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
Yes
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
43.24 x 4.40 x 21.93 cm
Shipping Dimensions ( H x W x D)
53 x 14 x 31 cm
Weight / Shipping Weight
2.87 / 5.8 kg
Power Cord Length
3m
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, CE-LVD, GOST, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE8108G
PE8208G
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
08
09
Metered Ready PDU
PE1216G / PE1324G / PE1213G / PE1316G
Features Connections Via EC1000 Energy Box Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2&V3 • Supports multi-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more Note: Refer to page 27 for EC1000 product details. • •
Metering Via EC1000 Energy Box •
Bank level current metering and monitoring
Outlet Switch Control •
Always On
Special Features • •
Lok-U-Plug – easily secures power cable to PDU Environment monitoring via EC1000
PE1216G
44
51.4
44
PE1216G
730 mm
PE1324G
1340
PE1213G 44
730
44
PE1324G
44
1340 1300
44
44
PE1316G
47
44
103.1 81.9
44
1300
PDUs for International Regions (IEC System)
Specifications Model
PE1216G
PE1324G
PE1213G
PE1316G
16A(Max)
32A(Max)
IEC 60309 32A
Electrical Nominal Input Voltage
100–240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
IEC 60309 32A
IEC60320 C20
Input Power
3680 VA(Max)
7360 VA(Max)
3680 VA(Max)
7360 VA(Max)
Total: 10 x IEC320 C13 + 3 x IEC320 C19
Total: 10 x IEC320 C13 + 6 x IEC320 C19 Bank1: Outlet 1 – 8; 5 x C13 + 3 x C19 Bank2: Outlet 9 – 16; 5 x C13 + 3 x C19
Outlet Type
Total: 16 x IEC320 C13
Total: 24 x IEC320 C13 Bank1: Outlet 1 – 12; 12 x C13 Bank2: Outlet 13 – 24; 12 x C13
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
C13: 10A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total) Breakers
16A(Max) 1 x 16A Non-Fuse Breaker
Metering
32A(Max)
16A(Max)
32A(Max)
2 x 16A UL489 Breaker
1 x 16A Non-Fuse Breaker
2 x 16A UL489 Breaker
Bank Level Current Monitoring (Via EC1000 Energy Box)
Outlet Switching
None
Environment Sensor Port
0
Metering Accuracy
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Mechanical Dimensions (H x W x D) Shipping Dimensions ( H x W x D)
73 x 4.4 x 4.4 cm
134 x 4.4 x 4.4 cm
73 x 4.4 x 4.4 cm
134 x 4.4 x 4.4 cm
83 x 20.8 x 12.7 cm
148.2 x 22.4 x 17 cm
83 x 20.8 x 12.7 cm
148.2 x 22.4 x 17 cm
1.3 / 4.9 kg
3.5 / 5.9 kg
1.3 / 4.9 kg
3.5 / 5.9 kg
3m
1.6 m
3m
1.6 m
Weight / Shipping Weight Power Cord Length
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, C-Tick, Others by Request
CE, Others by Request
Safety Verification
TUV-CB, GOST, Others by Request
CE-LVD, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Part No.
Description
EA1140
Temperature
EA1240
Temperature / Humidity
EA1340
Differential Pressure / Temperature
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07 2X-EA08 2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
Refer to page 33 for more information. PE1216G
PE1324G
PE1213G
PE1316G
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
•
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
•
10
11
Metered Ready PDU
PE2220G / PE2340G
Features Connections Via EC2004 Energy Box Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • Supports multi-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more Note: Refer to page 27 for EC2004 product details. • •
Metering Via EC2004 Energy Box •
Bank level current & power metering and monitoring
Outlet Switch Control •
Always On
Special Features • •
Lok-U-Plug – easily secures power cable to PDU Environment monitoring and door sensors via EC2004
PE2220G
PE2340G
691.4
44
79.2
66
PE2220G
44
66
PE2340G
1325
PDUs for International Regions (IEC System)
Specifications Model
PE2220G
PE2340G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
3680 VA(Max)
7360 VA(Max)
Total: 20 x IEC320 C13
Total: 40 x IEC320 C13 Bank1: Outlet 1 – 20; 20 x C13 Bank2: Outlet 21 – 40; 20 x C13
Outlet Type
IEC 60309 32A
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total) Breakers
16A(Max)
32A(Max)
1 x 16A Non-Fuse Breaker
2 x 16A UL489 Breaker
Metering
Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box)
Outlet Switching
None
Environment Sensor Port
0
Metering Accuracy
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Mechanical Dimensions (H x W x D) Shipping Dimensions ( H x W x D)
56.6 x 6.6 x 4.4 cm
132.5 x 6.6 x 4.4 cm
77.9 x 16.7 x 17.3 cm
143.3 x 24.8 x 19.4 cm
4 / 8.1 kg
4.2 / 8.4 kg
3m
1.6 m
Weight / Shipping Weight Power Cord Length
Environmental Temperature (Operating / Storage)
0–40˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Part No.
Description
EA1140
Temperature
EA1240
Temperature / Humidity
EA1340
Differential Pressure / Temperature
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07 2X-EA08 2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G 2X-018G 2X-019G
Side Panel Double Mount Kit
Refer to page 33 for more information. PE2220G
PE2340G
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
Button Mount Kit
•
•
Side Panel Mount Kit
•
•
12
13
Metered PDU (16A)
PE5216G / PE5220sG
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control •
Always On
Special Features PE5220sG
•
Lok-U-Plug – easily secures power cable to PDU
1324.8 mm
66
PE5216G
44
69 76.4
PE5216G
66
PE5220sG
PE5216G
PE5220sG
44
691.4
PDUs for International Regions (IEC System)
Specifications Model
PE5216G
PE5220sG
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
3680 VA(Max) Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Outlet Type Nominal Output Voltage
Total: 20 x IEC320 C13 100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
C13: 10A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
16A(Max)
Breakers
1 x 16A Non-Fuse Breaker
Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
None
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
132.5 x 6.6 x 4.4 cm
69.1 x 6.6 x 4.4 cm
142 x 16 x 17 cm
77.9 x 16.7 x 17.3 cm
Shipping Dimensions ( H x W x D) Weight / Shipping Weight
3.5 / 7.5 kg
2.1 / 4 kg
Power Cord Length
3m
Environmental Temperature (Operating / Storage)
0–50°C UL 60950
0–40°C / -20–60°C
Humidity (Operating , Storage)
( EN 60950 de-rated 0-30˚C ) / -20–60°C
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, C-Tick, Others by Request
CE, Others by Request
Safety Verification
TUV-CB, GOST, Others by Request
TUV-CB, CE-LVD, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE5216G
PE5220sG
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
•
•
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
• •
•
14
15
Metered PDU (32A)
PE5324G / PE5324LG
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control •
Always On
Special Features •
Lok-U-Plug – easily secures power cable to PDU Low profile dimension: PE5324LG
1775 mm
79.2 119.2
44
1775
66
PE5324LG
44
PE5324LG PE5324G
66
PE5324G
55
•
PDUs for International Regions (IEC System)
Specifications Model
PE5324G
PE5324LG
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
32A(Max)
Input Frequency
50-60 Hz
Connection
IEC 60309 32A
Input Power
7360 VA(Max)
Outlet Type
Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
32A(Max)
Breakers
2 x 16A UL489 Breaker
Metering
2 x 16A Slim Breaker
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
None
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
177.5 x 6.6 x 4.4 cm
Shipping Dimensions ( H x W x D)
189 x 21x 17 cm
Weight / Shipping Weight
6 / 10 kg
5.9 / 9.9 kg
Power Cord Length
1.6 m
Environmental Temperature (Operating / Storage)
0–40°C / -20–60°C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, C-Tick, Others by Request
CE, Others by Request
Safety Verification
TUV-CB, GOST, Others by Request
CE-LVD, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE5324G
PE5324LG
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
2X-015G
Double Mount Rail
•
•
2X-016G
Slide Rail Kit
•
•
2X-017G
Button Mount Kit
•
•
2X-018G
Side Panel Mount Kit
•
•
2X-019G
Side Panel Double Mount Kit
•
•
16
17
Metered PDU (32A)
PE5340sG / PE5340SLG / PE5312sGL / PE5312sGR
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control •
Always On
Special Features • •
Lok-U-Plug – easily secures power cable to PDU Low profile dimension: PE5340SLG
1359.8 mm
79.2
44
47
66
PE5340sG
1359.8
44
PE5340sG
55
66
PE5340SLG
1359.8
66
PE5312sGL
44
79.2
PE5340SLG
1359.8
79.2
44
66
PE5312sGR
PDUs for International Regions (IEC System)
Specifications Model
PE5340sG
PE5340SLG
PE5312sGL
PE5312sGR
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC 60309 32A
Input Power
7360 VA(Max) Total: 40 x IEC320 C13 Bank1: Outlet 1 – 20; 20 x C13 Bank2: Outlet 21 – 40; 20 x C13
Outlet Type
Total: 12 x UK BS1363 Bank1: Outlet 1 – 6; 6 x UK BS1363 Bank2: Outlet 7 – 12; 6 x UK BS1363
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max)
BS1363: 13A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
32A(Max)
Breakers
2 x 16A UL489 Breaker
Metering
2 x16A Slim Breaker
2 x16A UL489 Breaker
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
None
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
135.9 x 6.6 x 4.4 cm
Shipping Dimensions ( H x W x D)
147 x 24.8 x 19.4 cm
Weight / Shipping Weight
4.6 / 9 kg
4.5 / 8.9 kg
Power Cord Length
5.4 / 8.1 kg 1.6 m
Environmental Temperature (Operating / Storage)
0–40°C / -20–60°C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request CE-LVD,TUV-CB, Others by Request
Safety Verification
CE-LVD, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE5340sG
PE5340SLG
PE5312sGL
PE5312sGR
EA1140
Temperature
•
•
•
•
EA1240
Temperature / Humidity
•
•
•
•
EA1340
Differential Pressure / Temperature
•
•
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
•
2X-015G
Double Mount Rail
•
•
•
•
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
•
•
2X-019G
Side Panel Double Mount Kit
• •
•
18
19
Switched PDU
PE6216G / PE6324G / PE6324LG
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering Bank level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power • Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order • •
Special Features Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices • Lok-U-Plug – easily secures power cable to PDU • Low profile dimension: PE6324LG •
PE6216G
1324.8 mm
44
69 76.4
66
PE6216G
1775
79.2 119.2
44
1775
55
66
PE6324LG
44
PE6324G
66
PE6324G
PDUs for International Regions (IEC System)
Specifications Model
PE6216G
PE6324G
PE6324LG
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
3680 VA(Max)
7360 VA(Max)
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Outlet Type
IEC 60309 32A
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
16A(Max)
Breakers
32A(Max)
1 x 16A Non-Fuse Breaker
Metering
2 x 16A UL489 Breaker
2 x 16A Slim Breaker
Bank Level Current, Voltage, VA, PF and kWh Monitoring
Outlet Switching
Yes
Environment Sensor Port
2
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D) Shipping Dimensions ( H x W x D)
132.5 x 6.6 x 4.4 cm
177.5 x 6.6 x 4.4 cm
142 x 16 x 17 cm
189 x 21 x 17 cm
Weight / Shipping Weight
3.7 / 7.7 kg
Power Cord Length
6.3 / 10.3 kg
6.2 / 10.2 kg
3m
1.6 m
Environmental Temperature (Operating / Storage)
0–50˚C / -20–60˚C
0–40˚C / -20–60˚C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, C-Tick, Others by Request
Safety Verification
TUV-CB, GOST, Others by Request
CE, Others by Request
TUV-CB, CE-LVD, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
CE-LVD, Others by Request
Refer to page 33 for more information.
Part No.
Description
PE6216G
PE6324G
PE6324LG
EA1140
Temperature
•
•
•
EA1240
Temperature / Humidity
•
•
•
EA1340
Differential Pressure / Temperature
•
•
•
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
2X-015G
Double Mount Rail
•
•
•
2X-016G
Slide Rail Kit
•
•
2X-017G
Button Mount Kit
•
•
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
•
•
•
•
•
20
21
Outlet-Metered PDU (16A)
PE7214G / PE7216G / PE7324G / PE7328G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering PDU and outlet level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control •
Always On
Special Features •
Lok-U-Plug – easily secures power cable to PDU
66
PE7214G
44
606.9 mm
1324.8
44
69 76.4
66
PE7216G
1775 mm
66
PE7324G
44
79.2 119.2
PE7324G
1359.8
79.2 119.2
66
PE7328G
47 44
PE7216G
PDUs for International Regions (IEC System)
Specifications Model
PE7214G
PE7216G
PE7324G
PE7328G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
3680 VA(Max)
Outlet Type
IEC 60309 32A 7360 VA(Max) Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 - 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 - 16; 7 x C13 + 1 x C19
Total: 12 x IEC320 C13 + 2 x IEC320 C19 Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
16A(Max)
Breakers
32A(Max)
1 x 16A Non-Fuse Breaker
Metering
Total: 24 x IEC320 C13 + 4 x IEC320 C19 Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19 Bank2: Outlet 15 – 28; 12 x C13 + 2 x C19
2 x 16A UL489 Breaker
Outlet Level Current, Voltage, VA, PF, kWh Monitoring
Outlet Switching
None
Environment Sensor Port
4
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
90.96 x 6.6 x 4.4 cm
132.5 x 6.6 x 4.4 cm
177.5 x 6.6 x 4.4 cm
135.9 x 6.6 x 4.4 cm
Shipping Dimensions ( H x W x D)
100 x 18.7 x 16.6 cm
142 x 16 x 17 cm
189 x 21 x 17 cm
142 x 16 x 17 cm
3.7 / 7.7 kg
6.2 / 10.2 kg
Weight / Shipping Weight
2.7 / 3.8 kg
Power Cord Length
3m
4.1 / 7.9 kg 1.6 m
Environmental Temperature (Operating / Storage)
0–40°C / -20–60°C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification Safety Verification
CE, Others by Request CE-LVD, Others by Request
CE-LVD, TUV-CB, Others by Request
Optional Accessories Type
Environment Sensors Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE7214G
PE7216G
PE7324G
PE7328G
EA1140
Temperature
•
•
•
•
EA1240
Temperature / Humidity
•
•
•
•
EA1340
Differential Pressure / Temperature
•
•
•
•
EA1440
Photo Door Sensor
•
•
•
•
EA1441
Inductive Proximity Door Sensor
•
•
•
•
EA1442
Reed Door Sensor
•
•
•
•
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
•
2X-015G
Double Mount Rail
•
•
•
•
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
• • •
•
•
•
•
•
22
23
Outlet-Metered-Switched PDU
PE8216G / PE8316G / PE8324G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering PDU and outlet level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups Outlet groups supported at the PDU level • Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power • Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order • •
Special Features Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices • Lok-U-Plug – easily secures power cable to PDU •
1324.8 mm
66
PE8216G
44
69 76.4
PE8216G
1359.8
66
PE8316G
44
79.2
PE8324G
1775
79.2 119.2
44
66
PE8324G
PDUs for International Regions (IEC System)
Specifications Model
PE8216G
PE8316G
PE8324G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
IEC 60309 32A
Input Power
3680 VA(Max)
7360 VA(Max)
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total) Breakers
Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Total: 6 x IEC320 C13 + 10 x IEC320 C19 Bank1: Outlet 1 – 8; 3 x C13 + 5 x C19 Bank2: Outlet 9 – 16; 3 x C13 + 5 x C19
16A(Max)
32A(Max)
1 x 16A Non-Fuse Breaker
2 x 16A UL489 Breaker
Metering
Outlet Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
Yes
Environment Sensor Port
4
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D) Shipping Dimensions ( H x W x D) Weight / Shipping Weight
132.5 x 6.6 x 4.4 cm
136 x 6.6 x 4.4 cm
177.5 x 6.6 x 4.4 cm
142 x 16 x 17 cm
147 x 24.8 x 19.4 cm
189 x 21 x 17 cm
3.9 / 7.9 kg
5.1 / 7.7 kg
6.5 / 10.5 kg
Power Cord Length
3m
1.6 m
Environmental Temperature (Operating / Storage)
0–40°C / -20–60°C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification Safety Verification
CE, Others by Request TUV-CB, CE-LVD, Others by Request
CE-LVD, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
TUV-CB, CE-LVD, Others by Request
Refer to page 33 for more information.
Part No.
Description
PE8216G
PE8316G
PE8324G
EA1140
Temperature
•
•
•
EA1240
Temperature / Humidity
•
•
•
EA1340
Differential Pressure / Temperature
•
•
•
EA1440
Photo Door Sensor
•
•
•
EA1441
Inductive Proximity Door Sensor
•
•
•
EA1442
Reed Door Sensor
•
•
•
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
2X-015G
Double Mount Rail
•
•
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
• • •
•
•
• •
24
25
Outlet-Metered-Critical-Load PDU (16A)
PE9216G / PE9222G / PE9324G / PE9330G
Features Connections Built-in 10/100 Mbps Ethernet port Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, V3 • 2-level account and password security, IP/MAC filters, SSL 128-bit data encryption, RADIUS • Supports eco Sensors software and browser access via IE, Firefox, Chrome, Safari and more • •
Metering PDU and outlet level power metering and monitoring Environment monitoring via external sensors for rack temperature and humidity readings and alerts • Current, voltage, power, power dissipation, temperature and humidity metering with threshold settings • •
Outlet Switch Control Remote power outlet control (On/Off, Power Cycle) by individual outlet or outlet groups Outlet groups supported at the PDU level • Supports multiple power control methods – Wake on LAN, Safe Shutdown, and Kill the Power • Power-on sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order • Critical load outlet – keeps power always on for critical load devices • •
Special Features Proactive Overload Protection (POP) automatically powers off outlets when current overloads to protect connected devices • Lok-U-Plug – easily secures power cable to PDU •
1324.8 mm
44
69 76.4
66
PE9216G
66
PE9222G
44
1324.6
79.2 119.2
44
PE9330G
1775
79.2 119.2
66
PE9324G
44
PE9216G
1775
66
PE9324G
PDU for International Region (IEC System)
Specifications Model
PE9216G
PE9222G
PE9324G
PE9330G
Electrical Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
16A(Max)
32A(Max)
Input Frequency
50-60 Hz
Input Connection
IEC60320 C20
Input Power
3680 VA(Max)
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
IEC 60309 32A 7360 VA(Max) Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Total: 19 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 14; 12 x C13 + 2 x C19 Bank1-2: Outlet 15 – 22; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
16A(Max)
Breakers
32A(Max)
1 x 16A Non-Fuse Breaker
Metering
Total: 26 x IEC320 C13 + 4 x IEC320 C19 Bank1-1: Outlet 1 – 14; 12 x C13 + 2 x C19 Bank1-2: Outlet 15 – 22; 7 x C13 + 1 x C19 Bank2: Outlet 23 – 30; 7 x C13 + 1 x C19
2 x 16A UL489 Breaker
Outlet Level Current, Voltage, VA, PF, kWh Monitoring
Outlet Switching
Bank1-1: None; Bank1-2: Yes
Bank1-1: None; Bank1-2: Yes; Bank2: Yes
Environment Sensor Port
4
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Mechanical Dimensions (H x W x D)
132.5 x 6.6 x 4.4 cm
Shipping Dimensions ( H x W x D)
142 x 16 x 17 cm
Weight / Shipping Weight
143 x 20.6 x 19.4 cm
3.8 / 7.8 kg
Power Cord Length
177.5 x 6.6 x 4.4 cm 189 x 21 x 17 cm
3.9 / 7.9 kg
6.4 / 10.4 kg
6.6 / 10.6 kg
3m
1.6 m
Environmental Temperature (Operating / Storage)
0–40°C / -20–60°C
Humidity (Operating , Storage)
0–80% RH, Non-Condensing
Compliance EMC Verification
CE, Others by Request TUV-CB, CE-LVD, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
CE-LVD, Others by Request
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
PE9216G
PE9222G
PE9324G
PE9330G
EA1140
Temperature
•
•
•
•
EA1240
Temperature / Humidity
•
•
•
•
EA1340
Differential Pressure / Temperature
•
•
•
•
EA1440
Photo Door Sensor
•
•
•
•
EA1441
Inductive Proximity Door Sensor
•
•
•
•
EA1442
Reed Door Sensor
•
•
•
•
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
•
•
•
•
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
•
•
•
•
2X-015G
Double Mount Rail
•
•
•
•
2X-016G
Slide Rail Kit
•
•
2X-017G
Button Mount Kit
•
•
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
•
•
•
•
•
•
26
27
Energy Monitoring Device
EC1000 / EC2004
Features Operation Space saving 1U rack mounting with front and rear mounting 4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents (0A to 32A per port, 2 Current Energy Sensors Ports, 2 Current / Voltage Energy Sensors Ports for EC2004) • 4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents for EC1000 (0A to 32A per port) • 4 RJ-11 Environment Sensor Ports to monitor temperature, humidity, and differential pressure* • 4-pin dry contact Rack Door Sensor status monitor (EC2004) • Maximum Amperage Monitor 32A@100V~240V (Energy Box) • 3 digit 7 segment front panel LED displays current/sensor/IP address information • Threshold monitoring for: - Current, Voltage - Temperature* - Humidity* - Differential pressure* • Threshold alerting through: - Local: audible alarm and LED lights - Remote: SMTP/SNMP trap/Syslog •
EC1000
EC2004
•
Management Front panel LED indicators for current, temperature*, humidity*, differential pressure*, and IP address information at the Energy Box • Remote real-time current/voltage, temperature*, humidity*, and differential pressure* monitoring and management • Management through eco Sensors Energy Management Software or 3r party SNMP manager • Supports name assignment for individual Energy PDUs • Event Logging – 128 line event log • Syslog support • F/W upgradable •
Remote Access Remote management via TCP/IP using built in 10/100Mbps Ethernet port Management via built in browser based GUI • Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping • Supports SNMP Manager V1, V2, V3 • •
Security Strong security features include password protection and advanced encryption technologies – utilizing 128 bit SSL • RADIUS authorization and authentication •
* Requires external sensors
Energy Monitoring Device
Specifications Function
EC1000
EC2004
Power
1 x DC Jack
Current Monitor
4 x RJ-45
Voltage / Current Monitor
Connectors
2 x RJ-45
N/A
2 x RJ-45
Env. Sensor
4 x RJ-11
Door Sensor
N/A
LAN
4 Pin Dry Contact
1 x RJ-45 Female with LEDs (Silver/LED Orange/Green)
Monitored PDU Status
4 (Orange)
Port Numbers
1 digit 7-segment (Orange)
Energy / Env. / IP Selection
3 (Green)
Current /Sensor / Voltage/ IP Address
3 digit 7-segment (Orange)
Power
LEDs
1 (Blue)
Door Sensor
1 (Red)
10M / 100 Mbps LAN
1 (Orange/Green)
Link
1 (Green)
Env. Sensor Status
4 (Green)
Reset
Switches
1 x Semi-recessed Pushbutton
Selection
1 x Selection Button, 1 x Up, 1 x Down 100–240V~; 50/60Hz; 0A to 32A, LED Display Resolution 0.1A Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Monitoring Range
Operating Temperature
0–50°C
Storage Temperature
-20–60°C
Operating / Storage Humidity
0–80% RH, Non-Condensing
Housing
Metal
Weight
0.64 kg
Size ( W × D x H )
20.00 x 7.59 x 4.20 cm
Optional Accessories Type Environment Sensors
Door Sensors
Cable Holders
Mounting Kits
Refer to page 33 for more information.
Part No.
Description
EC1000
EC2004
EA1140
Temperature
•
•
EA1240
Temperature / Humidity
•
•
EA1340
Differential Pressure / Temperature
•
•
EA1440
Photo Door Sensor
•
EA1441
Inductive Proximity Door Sensor
•
EA1442
Reed Door Sensor
•
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
28
29 Strategic Operational Dashboard
DCie
RCI-HI
eco Sensors - A Comprehensive Solution for Data Center Optimization
What is eco Sensors software? eco Sensors software gives you the tools to create a fully optimized, energy efficient data center. The software combines ATEN’s cutting edge eco-technology with an intuitive GUI to deliver the best Data Center Infrastructure Management (DCIM) software on the market. ATEN’s eco Sensors software not only gives you the means to assess, diagnose and estimate your energy saving potential, it provides advice on the best way to do it.
Overview ATEN’s eco Sensors perfectly synergize with NRGence ™ Energy Intelligence PDUs to provide the mechanisms you need to optimize your data center energy needs. The software and PDU can measure the Dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI). This allows data center administrators to analyze the operational efficiency of equipment versus the cost of cooling, in order to better manage power allocation. These indexes have been incorporated into the U.S. Department of Energy DC Pro software tools for data center energy assessments and the Data Center Energy Practitioner program. Using ATEN’s NRGence™ Energy Intelligence PDU and eco Sensors energy & DCIM management software, an administrator’s data center is equipped with real time monitoring, measurements and EnPIs analysis, that produce reports of power usage, PUE, RCI and RTI to meet the ISO 50001 requirements. With these critical indexes, you can generate customized reports about your data center’s status that include energy saving suggestions. Following these suggestions allows you to optimize energy usage to save energy without harming your IT equipment’s reliability. Real-time Rack Status Monitoring ATEN’s eco Sensors software is available in a Master and Client version. The Master version offers the full functionalities of the eco Sensors software, and is capable of managing the PDU through SNMP and managing the client node through TCP/IP. This allows multiple users to log in to the master node concurrently to manage PDUs in different authorized zones, making distributed PDU management much more efficient under one centralized environment. With the Client version, users are allowed to log in to a master node to monitor PDU status and control each outlet on the PDUs. Having a Master and Client version allows data centers to optimize their performance and centralize their management.
Master Version Offers full functionalities of eco Sensors Manage clients through TCP/IP Manage PDUs through SNMP Client Version Users are allowed to log in to the Master version Real time functions: Dashboard / Power Control / Group Control eco Sensors Client Version eco Sensors Client Version
eco Sensors Master Version
eco Sensors Client Version IP Network
MySQL
IP Network
eco Sensors Master & Client Version
30
The Benefits of Using eco Sensors Power Measurement and Scheduling By Zone – eco Sensors allows you to group racks in your data center in up to 128 zones, or define areas that you wish to get readings for. Administrators can schedule power on & off by zone or monitor the real-time stats such as peak and average power usage per zone.
Power Analysis Report – eco Sensors offers comprehensive power analysis reports which can be separated by departments and locations. It displays trend charts in real-time or according to the day, month, year, or grasp the power consumption needs for each of the four seasons. By knowing actual power consumption trends, you can allocate power resources without waste and prevent wasted power capacity. Optimum Data Center Energy Management – When used in conjunction with Sensor-enabled eco PDUs, eco Sensors Energy Management Software provides administrators with a real time Rack Cooling Index ® and dynamic power analysis to protect IT equipment from excess heat or insufficient power capacity.
Fan Energy Saving & Chiller Energy Saving – eco Sensors software provides real-time power measurements and environment monitoring information of your data center in a variety of formats, such as zone, rack, device or outlet level. By generating customized reports about your data center’s status, administrators can evaluate the potential Fan Energy Saving & Chiller Energy Saving percentage. Furthermore, administrators can also realize how long it will take to recover the invested resources, confirming the investment returns.
Energy Saving Estimates
Zone Setting
Temperature Sensor
Unreachable
Normal
1
2
3
4
Warning
6
5
Critical
7
8
9
Differential Pressure Sensor
1
5
10
A 1
5
10
15
20
25
Internet/ LAN
Report Title: Sales Department IT Power Analysis
IT Office
Daily Report: 2011/1/1 – 2011/5/5 by Bill Li
IT Power Usage Chart kWH
IT Power Load Chart kWH
- Sales 3
6
6
4 2
IT Office eco PDU Sensor Probes
Server Storage
4
- Sales 2
Sales
2
- Sales 1 1/1 2/2 3/3 4/4 5/5
1/1 2/2 3/3 4/4 5/5
IT Inventory List in Report No.
Name Peak Watts
Peak
CO2e/Hrs
Yearly Power Cost
Yearly CO2e Cost
Location
01
Web Server
3
1.8 kg
1200
600
L25
02
Log Server
6
3.6 kg
3600
1800
L27
31
PE1216GSoftware / PE1324G/ eco PE1213G/ PE1316G Metered Energy & Ready DCIM Management PDU Sensors
Features • Automatic discovery of all PE devices within the same intranet • Remote real-time power measurement and monitoring -PDU level current / voltage / power dissipation / power consumption -Outlet ON / OFF / Recycle status • Second window to monitor data center status including PUE, RTI, RCI, Power, Carbon Footprint and rack status • Remote real-time power outlet management* -Power outlet ON / OFF / Cycle switching by outlet or user-defined group -Power outlet ON / OFF / Cycle switching with pre-defined schedule -User-defined outlet level delays for sequential power up -Current / Voltage / Power Dissipation / Power Consumption threshold level setting -User access assignment for every outlet -Name assignment to individual outlets • Remote real-time environment sensor monitoring -Temperature / Temperature + Humidity reading / Temperature + Differential Pressure -Temperature and Humidity threshold level setting • Plotting/Monitoring of all PE devices -Add data center server racks -Add PE devices for each server rack -Manage device/device outlet status for each plot • Offers essential data center indices including Rack Intake Temperature, Rack Exhaust Temperature, Rack Equipment Temperature Difference, RCI ( Rack Cooling Index ), RTI ( Return Temperature Index ), RHI ( Rack Humidity Index ), RPI ( Rack Pressure Index ), RAI ( Rack Airflow Index ) • Power analysis report for optimiz nter energy management – including power usage, power load, power cost, CO2 cost, power capacity and trend • Exceed threshold alert through SMTP and System log • 10240 line event log • System log provision • Two-level password security • Strong security features include password protection and advanced encryption technologies – 128 bit SSL *Not all functions are supported by all eco PDU PE models. Please see www.aten.com for more details.
Temperature Sensor Number
Overall Rack Cooling Effectiveness
Power Control
Energy & DCIM Management Software
Functions
Energy
User
Device
System
Log
Master Version
Client Version
Dash Board
Real time monitor power usage information, temperature and humidity
•
•
Power Control
Monitor PDU status and control power outlet
•
•
Group Control
Control power outlet by group
•
•
Power Analysis
Power Usage Analysis by hour, day, month or quarter
•
Thermal Analysis
Thermal Analysis by hour, day, month or quarter
•
Account
Account Management, access right by function, device and group
•
Zone Define
Define data center zone
•
Rack Install
Install server rack in data center
•
Device Setup
Setup PDU or Energy Box in data center
•
Define Data Group
Define data group for report analysis, group control and schedule control
•
In-Synergy Gateway
Support external gateway for CT meter
•
Sys Settings
System parameters, SNMP and SMTP Settings
•
Maintenance
PDU and energy box firmware upgrade
•
Database
Database settings, capacity management, import/export, config backup/restore
•
Task
Scheduling group outlet control and config backup
•
Billing
Electricity billing report
•
System Log
View system log
•
Log Options
Log Settings
•
Events
Event Settings
•
Hardware Requirements Operating System CPU Display Memory Disk Network
Master Version
Client Version
Windows 7/Windows Server 2003 and later
Windows 7/Windows Server 2003 and later
2.5 GHz Quad Core
2.0 GHz Dual Core
Larger than 1024x768
Larger than 1024x768
4GB
2GB
500GB
100GB
10/100 Mbps Ethernet
10/100 Mbps Ethernet
System Parameter Master Version
Max Account Number Concurrent Login Max PDU Number Data Center Layout
128 8 2500 45x30 72x48 90x60
Max Rack Number
2500
Max Zone Number
128
Power Report Data
At least 3 years
Real Time Dashboard Data
300GB
32
33
Metered Ready Optional Accessories PDU
Type
PE1216G / PE1324G/ PE1213G/ PE1316G
Part No.
Description
EA1140
Temperature
EA1240
Temperature / Humidity
EA1340
Differential Pressure / Temperature
EA1440
Photo Door Sensor
Images
Installation
Environment Sensors
Inside Rack Door
EA1441
Inductive Proximity Door Sensor
Door Sensors
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
Cable Holders
Rack Frame Door
Optional Accessories
Type
Part No.
Description
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
Mounting Kits
Images
Installation
34
Belgian Subsidiary ATEN Infotech N.V. Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgium ahttp://www.aten.eu E-mail: sales@aten.be
Corporate Headquarters ATEN International Co., Ltd. 3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan Phone: +886-2-8692-6789 Fax: +886-2-8692-6767 http://www.aten.com E-mail: marketing@aten.com
Belgian Subsidiary ATEN Infotech N.V.
Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgium Phone: +32-11-531543 Fax: +32-11-531544 http://www.aten.eu E-mail: sales@aten.be
Corporate Headquarters ATEN International Co., Ltd.
3F., No.125, Sec. 2, Datong Rd., Sijhih District., New Taipei City 221, Taiwan Phone: +886-2-8692-6789 Fax: +886-2-8692-6767 http://www.aten.com E-mail: marketing@aten.com
© Copyright 2015 ATEN® International Co., Ltd.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners.
Printed 03/2015 V1.1