MedizinTechnik
octors d d n a ts MOS“ T „Patien A n o rely e d i w d l wor
2012 | 2013 Surgical suction devices & thoracic drainage systems
Table of contents OT-Suction systems
ATMOS Record 55 DDS The powerful allrounder!
ATMOS C 451 / ATMOS C 361 Top performance in the OT at a fair price. The new standard in OT suction!
................................................................................................... page
5 to 9
............................................................................................. page
10 to 18
General Consumables
General surgery Other Accessories and Consumables
ATMOS S 351 Top-class drainage/surgical suction devices. The „thinking“ suction system. ............................................................................................. page
19 to 24
............................................................................................. page
Direct-Docking-System (DDS)
DDS-System Secretion management at the highest stage – Innovative container systems from ATMOS ..............................................................................................................page
Symbols
DVD
Helpful information 2
4
DVD to this topic available
25 to 28
MedizinTechnik
Thoracic drainage
Radiofrequency surgery
ATMOS S 201 Thorax / ATMOS E 201 Thorax The new generation of mobile thoracic drainage systems including therapy success monitoring. ............................................................................................. page
29 to 35
ATMOS RS 221 Cutting and coagulation with maximum precision!
............................................................................................. page
36 to 43
Vacuum and Compressed air
Smoke evacuation
AtmoSafe The most powerful smoke evacuation suction system!
ATMOS ZV 60 / ATMOS ZD 60 Vacuum regulator and suction systems for central vacuum supply and central compressed air supply.
............................................................................................. page
............................................................................................. page
44 to 52
53 to 60
Service worldwide
We offer you complete support so you can care for your patients!
............................................................................................. page
61 to 78
ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone +49 7653 689-374 Fax +49 7653 68986-374 ApplicationSolutions@atmosmed.de www.atmosmed.com 3
ATMOS DDS system MedizinTechnik
Secretion management at the highest level – Innovative canister systems from ATMOS DDS-jar handle, PSU DDS-bacterial filter / oversuction stop, hydrophobic, disposable part DDS-hose adaptor set, Ø 6 + 10 mm DDS-jar lid with gaskets DDS-splash protection DDS-collection jar, polysulphone, 3.0 l
The Direct Docking System for quick, hose-free connection of collection jar and pump
Again and again hose connections are mixed up between suction units and secretion canisters; this results in damaged equipment, expensive repairs and a reduced service life for normal surface filters.
The system features are easy handling during use in the OT. The simple DDS system avoids misuse of the equipment while in theatres. Innovations which facilitate your daily work!
In times of technical innovations this must no longer be accepted. ATMOS offers the perfect solution for these problems.
Secretion management with reprocessable containers: The ATMOS Direct-Docking-System (DDS)
The ATMOS DDS is compatible with the following products:
The hose connections between the suction unit and the secretion canister are omitted and with it easy handling is guaranteed.
ATMOS Record 55 DDS
The DDS filter is a high-performance filter with an internal filter surface (> 1m2 per filter) which is much larger than the surface of a usual surface filter.
ATMOS C 361
The DDS filter prevents the penetration of bacteria into the system and with it the contamination of device and environment. The hydrophobic attributes of the DDS filter prevent the penetration of foam, liquid and aerosol into the pump. Oversuction is almost impossible and expensive repairs are not required.
Foam formation is reduced due to the new design of the inlet. In addition the filter service life is increased.
4
ATMOS C 451 ATMOS ZV 60 ATMOS ZD 60
MedizinTechnik
ATMOS Record 55 DDS Top-class, mobile surgical suction device. Strong, silent and powerful!
The silent top performer!
5
ATMOS Record 55 DDS
ATMOS Record 55 DDS The powerful allrounder!
The ATMOS Record 55 DDS is most suitable for the versatile use in OT due to the high suction performance and the powerful vacuum. The ATMOS Record 55 DDS is the first choice when a silent but powerful suction system is required. Improved technology makes the Record 55 a reliable system for many surgical applications: it is particularly effective for aesthetic plastic surgery and liposuction procedures: Visceral surgery Orthopaedic surgery Thorax surgery Vascular surgery, etc. In particular with regard to aesthetic-plastic surgery especially liposcution - the ATMOS Record 55 DDS is most suitable.
6
The advantages of the ATMOS Record 55 DDS at a glance: Powerful: The airflow rate of 55 litres per minute always provides a free vision in the operating field. Almost noiseless: Low operation noise for concentrated work in the OT. Easy handling Hygienic: Modern canister systems and filters protect staff and patients. Reliable: Approved technology guarantees trouble-free operation. No breakdown caused by blocked bacterial filter
MedizinTechnik
Hose connection with twisted inlet, reduces foam formation and thereforee, longer filter duration.
Quick exchange of bacterial filter which has an extended filter surface.
Changeover lever for comfortable selection of the collection jar during trolley operation.
Foot switch available as an option, anaesthetic proof.
7
| OT suction systems | ATMOS Record 55 DDS - User packages
ATMOS Record 55 DDS
User packages Silent, powerful and user-friendly. The surgical suction device with maximum performance!
Top suction performance Almost noiseless Easy handling
Short start-up time
ATMOS Record 55 DDS - User packages
ATMOS Record 55 DDS (2 x 3 l canister) Mobile surgical suction unit for very high demands, Quiet running, infinitely variable vacuum control, damped vacuum display, change-over for canister selection, for direct docking system canisters, connection for foot controller Technical data: Air-flow rate of pump: 55 ± 3 l/min, vacuum -98 kPa/-735 mmHg at sea level, 230 V~, 50/60 Hz, dimensions (H x W x D): 940 x 500 x 390 mm
REF ❁ 444.0930.0
Included in delivery: basic unit, operating instructions, mains cable, 2 DDS canisters 3 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set Ø 6 mm / Ø 10 mm), suction hose Ø = 6 mm, L = 2.10 m
ATMOS Record 55 DDS (2 x 5 l canister)
Included in delivery: basic unit, operating instructions, mains cable, 2 DDS canisters 5 l, 2 DDS canister lids, 2 DDS canister handle, 2 DDS splash protection, 10 DDS-bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), suction hose Ø = 6 mm, L = 2.10 m
❁ 444.0940.0
Included in delivery: basic unit, operating instructions, mains cable, standard rail (assembled)
❁ 443.0700.0
ATMOS Record 55 with standard rail
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 8
MedizinTechnik
➀
Accessories for all ATMOS Record 55 user packages ➀ Foot switch ➁ Foot regulator set For vacuum control ➂ Deposit tray, stainless steel with support for rail system ➃ Hose support, stainless steel for attaching to standard rail
REF
❁ 443.0755.0 ❁ 443.0770.0 ❁ 443.0790.0
❁ 320.0611.0
You can find further accessories from page 25 on
➁
➂
➃
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 9
ATMOS C 451 / ATMOS C 361 MedizinTechnik
ATMOS C 451 / ATMOS C 361 Top performance in the OT at a fair price.
10
The new standard in OT suction! Elegant and powerful!
ATMOS C 451
ATMOS C 361
The standard in OT suction!
The cost-effective solution!
ATMOS C 451 with 2 x 3 l OT package
ATMOS C 361 with practice package 3 l and trolley
ATMOS C 451
ATMOS C 361
The innovation of the ATMOS C 451 lies in the details: With the innovative DDS (Direct Docking System) it is simpleto disconnect canister, filter and suction hose from the suction unit - and when using the DDS canister system - can bw sterilised and used again. And all this within shortest time! In addition errors in hose connection are completely ruled out. At the same time it is possible to conveniently select the canisters by means of a changeover lever.
For suction procedures with less power requirements the ATMOS C 361 is most suitable: Suction pump with at least 36 l/min, max.-91 kPa Operation without foot switch With trolley Apart from that you can benefit from the same advantage as the ATMOS C 451. Decide for yourself!
11
ATMOS C 451 / ATMOS C 361 MedizinTechnik
Characteristics ATMOS C 451 / ATMOS C 361 – at a glance
ATMOS C 451 with system trolley
ATMOS C 451 table-top device
ATMOS C 361 with trolley
ATMOS C 361 table-top device
Suction pump 45 l
|
|
Suction pump 36 l
|
|
Single-canister system
v
|
v
|
v
v
|
|
| |
|
|
|
Double-canister system ATMOS DDS ( 1,5 l, 3 l) Foot controller / switch Antistatic castors Precision vacuum gauge Carrying handle and container lid Changeover lever Infinitely variable vacuum control
= Standard version
12
| = not available
v = optional available
| OT suction systems | ATMOS C 451 Systems with reusable DDS canisters MedizinTechnik
ATMOS C 451 mobile
Mobile versions
The new benchmark in Design and operability
Secretion management Filter technology
ATMOS C 451 Systems with reusable DDS canisters
ATMOS C 451 with 2 x 3 l canister Powerful surgical suction unit for high demands. Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ball-shaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 45 l/min +/-5 l/min, 230 V~, ± 10%, 50/60 Hz, dimensions: (H x W x D): 330 x 240 x 360 mm, with system trolley 1010 x 360 x 440 mm.
REF ❁ 340.0334.0
Included in delivery: basic unit, mains cable, operating instructions, 2 DDS canisters 3 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, DDS changeover docking station, system trolley, suction hose Ø = 6 mm, L = 2.10 m, standard rail adapter
ATMOS C 451 with 2 x 5 l canister
Included in delivery: basic unit, mains cable, operating instructions, 2 DDS canisters 5 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, DDS changeover docking station, system trolley, suction hose Ø = 6 mm, L = 2.10 m, standard rail adapter
❁ 340.0333.0
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 13
| OT suction systems | ATMOS C 451 Systems with reusable DDS canisters
Systems with reusable canisters DDS
ATMOS C 451 with practice package 1.5 l
Included in delivery: basic unit, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister handle, DDS splash protection, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m
❁ 340.0339.0
Included in delivery: basic unit, mains cable, operating instructions, DDS canister 3 l, DDS canister lid, DDS canister handle, DDS splash protection, 10 DDS-bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m
❁ 340.0338.0
ATMOS C 451 with practice package 3 l
ATMOS C 451 mobile with standard rail Designed for continuous operation, silent running, quick mount mechani connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against penetration of liquids, integrated extra large precision vacuum indica loss-free infinitely variable ballshaped vacuum regulator. Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m, standard rail set
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 14
REF
❁ 340.0358.0
MedizinTechnik
➀
➁
➂
Accessories for ATMOS C 451 ➀ DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector ➁ Tray for system trolley ➂ Trolley with standard rail ➃ DDS-standard rail adapter with vacuum connection for the use of disposable systems at the unit Foot switch ➄ Pedal regulator (0...-91 kPa) for infinitely variable vacuum regulation, especially with vacuum extraction, liposuction etc. (can also be retrofitted) DDS-canister set 2 x 3 l consisting of: ▪ 2 DDS secretion canisters 3 l ▪ 2 DDS canister lid sets ▪ 10 DDS-bacterial filters with integrated oversuction stop ▪ 1 suction hose, L = 2 m, Ø 12 mm DDS-canister set 2 x 5 l consisting of: ▪ 2 DDS-collection canister 5 l, polysulphone ▪ 2 DDS-canister lid set ▪ 10 DDS-bacterial filter/oversuction stop ▪ 1 suction hose ➅ DDS-canister lid, complete set consisting of: DDS canister lid, DDS canister handle, DDS splash protection, DDS hose adapter set (Ø 6 mm + Ø 10 mm), DDS bacterial filter oversuction stop, hose holder on DDS canister
REF
❁ 340.0062.0 ❁ 340.0084.0 ❁ 320.0070.1 ❁ 340.0059.0 ❁ 443.0755.0 ❁ 443.0310.1 ❁ 444.0901.0
❁ 444.0902.0
❁ 340.0045.0
You can find further accessories from page 25 on
➃
➄
➅
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 15
| OT suction systems | ATMOS C 451 basic unit
ATMOS C 451 portable
Portable basic unit
The new benchmark in Design and operability
Secretion management Filter technology
ATMOS C 451 basic unit
ATMOS C 451 Powerful surgical suction unit for high requirements. Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ball-shaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 45 l/min +3/-5 l/min, 230 V~, ± 10%, 50/60 Hz, dimensions (H x W x D): 330 x 240 x 360 mm Included in delivery: basic unit, mains cable, operating instructions
ATMOS C 451 portable with standard rail
Technical data
ATMOS C 451 basic unit
Operating time
> 12 h continuous operation without intermittence, within 24 h
Noise level Voltage Weight
Vacuum indicator
Power consumption Capacity of suction
≤ 48 dB (A) @ 1 m (ISO 7779) at max vacuum
230 V~ ± 10%, 50/60 Hz; special voltage: 100 V~ ± 10%, 50/60 Hz; 115 V~ ± 10%, 50/60 Hz; 127 V~ ± 10%, 50/60 Hz approx. 6.7 kg (with secretion container)
-1...0 bar ± 16 mbar (class 1.6) Ø 63 mm max. 173 W
45 l/min +3/5 l/min
The stated technical data are valid at the moment of printing, and are subject to change!
16
REF ❁ 340.0300.0
❁ 340.0357.0
| OT suction systems | ATMOS C 361 Systems with reusable canisters MedizinTechnik
ATMOS C 361
Basic equipment incl. practise package Secretion management - simple, safe and high efficient!
Suction system with at least 36 l /min, - 91 kPa
Can be adapted to trolley with canisters on standard rail system without ATMOS DDS system
ATMOS C 361 Systems with reusable canisters
REF
ATMOS C 361 with practice package 1.5 l Powerful surgical suction unit for high demands. ❁ 340.0351.0 Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ballshaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 36 l/min ± 4 l/min, 230 V~ ± 10%, 50/60 Hz, Dimensions (H x W x D): 330 x 240 x 360 mm Included in delivery: basic unit, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister handle, DDS splash protection, DDS bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m
ATMOS C 361 with practice package 3 l
Included in delivery: basic unit, mains cable, operating instructions, DDS canister 3 l, DDS canister lid, DDS canister handle, DDS splash protection, DDS bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m
❁ 340.0350.0
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 17
| OT suction systems | ATMOS C 361 Systems with reusable canisters
ATMOS C 361 mobile with standard rail Designed for continuous operation, silent running, quick mount mechanism forconnection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, lossfree infinitely variable ball-shaped vacuum regulator, DDS port for the hose-free connection of the pump to the DDS canister.
REF
❁ 340.0360.0
Included in delivery: Basic device, system trolley, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister carrying handle, DDS splash protection, 10 DDS bacterial filter with integrated overflow protection, DDS hose adapter set, DDS hose holder, suction hose l = 2.1 m
ATMOS C 361 mobile with 3.0 l practice package Designed for continuous operation, silent running, quick mount mechanism forconnection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, lossfree infinitely variable ball-shaped vacuum regulator, DDS port for the hose-free connection of the pump to the DDS canister.
❁ 340.0361.0
Included in delivery: Basic device, system trolley, mains cable, operating instructions, DDS canister 3.0 l, DDS canister lid, DDS canister carrying handle, DDS splash protection, 10 DDS bacterial filter with integrated overflow protection, DDS hose adapter set, DDS hose holder, suction hose l = 2.1 m
ATMOS C 361 mobile with standard rail Designed for continuous operation, silent running, quick mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, loss-free infinitely variable ball-shaped vacuum regulator.
❁ 340.0362.0
Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m
ATMOS C 361 portable with standard rail Designed for continuous operation, silent running, quick mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, loss-free infinitely variable ball-shaped vacuum regulator.
❁ 340.0363.0
Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m, adapter for standard rail system
Accessories for ATMOS C 361 Trolley with standard rail DDS-standard rail adapter with vacuum connection for the use of disposable systems at the unit
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 18
❁ 320.0070.1 ❁ 340.0059.0
MedizinTechnik
ATMOS S 351 Top-class drainage/surgical suction device. The“thinking“ suction system!
The universal suction specialist for: Neurosurgery Cardiac Surgery Gastroenterology Urology General Surgery
19
ATMOS S 351
ATMOS S 351
g
f
h
What are your basic requirements with regard to a suction system in the operating theatre? Considerable demands are made with regard to the reliability of medical technology especially in critical operating situations. During your daily work you are exposed to a noise level, which should not be underestimated – you do not need a rise in noise level due to the suction device employed in this connection! In support of this ATMOS has a suction unit in that range which meets the following requirements: Absolutely stable vacuum due to processor controlled regulation automatism
20
100% precise vacuum setting due to sensor technology Tissue protection function: prevents damage to sensitive tissue caused by adherent cannulas. Whenever a pre-set maximum vacuum limit is reached, a valve opens and the suction system „lets go“. Automatic Standby Function: The system starts up automatically when secretion has to be extracted and stops when the secretion has been completely removed. In brief: small mobile, quiet, safe and secure!
MedizinTechnik
The processor-controlled c automatic control system Simple and rapid vacuum preselection at the touch of a button, no loss of air, unlike mechanical vacuum controllers
d Intermittent suction for drainage applications
Specially designed safety f jar ensures no damage is caused by oversucking Safety jar without filter REF 444.0646.0 Safety jar with filter REF 444.0646.1
g Hydrophobic bacterial filter with filter replacement indicator REF 443.0738.0
display e High-resolution showing desired/actual vacuum choice of mbar, mmHg oder kpa
Double socket nipple for h rapid jar replacement REF 444.0012.0
21
| OT suction systems | ATMOS S 351
ATMOS S 351 OT
Basic equipment The „thinking“ suction system for OT and ward!
Advantages in OT: Protects delicate tissue from suction adherence Vacuum preselection at the touch of a button Almost noiseless
ATMOS S 351
REF
ATMOS S 351 OT basic unit 1.5 l canister (PSU) Microprocessor-controlled suction unit ❁ 444.0461.0 with graphic-LCD-display, automatic vacuum control, standby automatic, filling level control with automatic switching off, suction adherence detection and intermittence for protecting delicate tissue and for gastroscopic and wound drainage, safety canister 250 ml for condensed water, bacterial filter with hydrophobic attribute. Technical data: pump performance: 36 l/min ± 2 l/min, Vacuum 90 kPa/-675 mmHg, 230 V~ ± 10%, 50/60 Hz, Dimensions: (H x W x D): 300 x 330 x 200 mm Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, set with 1.5 l canister (PSU) incl. lid and double socket nipple, hydrophobic bacterial filter, hose holder, hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.3 m
ATMOS S 351 OT set with 2 x 3 l canister (PSU)
Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, set with 2 x 3 l canister (PSU) incl. lid and double socket nipple, hydrophobic bacterial filter, hose holder, hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.3 m
❁ 444.0471.0
ATMOS S 351 - basic unit Microprocessor-controlled suction unit ❁ 444.0460.0 with graphic-LCD-display, automatic vacuum control, standby automatic, filling level control with automatic switching off, suction adherence detection and intermittence for protecting delicate tissue and for gastroscopic and wound drainage, small secretion canister 250 ml incl. bacterial filter with hydrophobic attribute. Technical data: pump performance: 36 l/min ± 2 l/min, Vacuum 90 kPa/-675 mmHg, 230 V~ ± 10%, 50/60 Hz, dimensions (H x W x D): 300 x 330 x 200 mm Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, hydrophobical bacterial filter, hose holder hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.30 m
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 22
MedizinTechnik
➀
➁
➂
Accessories for completing the ATMOS S 351 ➀ Secretion canister lid incl. standard rail holder with overflow electrode and splash protection ➁ Double socket nipple consisting of double socket nipple and hose reduction Graduated secretion canister 1.5 l Height 192 mm, external Ø 115 mm Secretion canister 1.5 l PSU, sterilisable up to 134 °C ➂ Graduated secretion canister 3 l Height 247 mm, Ø 145 mm Secretion canister 3 l PSU, sterilisable up to 136 °C Graduated secretion canister 5 l Height 302 mm, Ø 169 mm Secretion canister 5 l PSU, sterilisable up to 136 °C Standard rail support For disposable system Medi-Vac® 1 l, 1.5 l. Safety canister 250 ml, for condensed water Safety canister 250 ml with integrated DDS-bacterial filter / overflow stop, incl. adapter for arthroscopy (Shaver, Lavagen), oral and maxillofacial surgery, liposuction etc. Hose holder, for attaching to standard rail (plastic, white) Basket for catheters, L = 340 mm Instrument quiver for attachment to standard rail, Ø 60 mm, height 170 mm Catheter quiver for catheter storage, with support for rail system, height 410 mm, Ø 105 mm, for standard rail 10 x 30 mm. Quiver holder incl. standard rail support, height 190 mm, Ø 55 mm, for standard rail 10 x 30 mm.
Technical data
ATMOS S 351 basic unit
Voltage
230 V~ 50/60 Hz; special voltage: 115 V~ 50/60 Hz
Noise level
Dimensions (H x W x D) Weight
Classifications Capacity of suction
REF
❁ 444.0015.0 ❁ 444.0012.0 ❁ 444.0032.0 ❁ 444.0036.0 ❁ 444.0033.0 ❁ 444.0037.0 ❁ 444.0034.0 ❁ 444.0038.0 ❁ 444.0451.0 ❁ 444.0646.0 ❁ 444.0646.1 ❁ 444.0450.0 ❁ 444.0140.0 ❁ 340.0065.0 ❁ 443.0780.0 ❁ 444.0145.0
46 dB (A) @ 1m (acc. to ISO 7779)
300 x 330 x 200 mm, without trolley; 840 x 490 x 520 mm, with trolley
10.2 kg, without secretion jar, without trolley; / with trolley: 24.7 kg
protection category: IPX0; protection class: I; degree of protection: type B, class: IIb (acc. to appendix IX dirctive 93/42 EEC) 44 ± 2 l/min
The stated technical data are valid at the moment of printing, and are subject to change!
23
| OT suction systems | Accessories for completing ATMOS S 351
➀
Accessories for completing ATMOS S 351 ➀ Trolley on 4 castors, self-assembly Attention: Trolley and small suction units cannot be screwed up in standard version! If required, we will deliver a special design of the suction unit. Trolley with antistatic castors ➁ Foot controller electrical, water-proof IPX 8, AP-protected
➁
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 24
REF
❁ 320.0070.0 ❁ 444.0020.0 ❁ 444.0452.0
MedizinTechnik
Miscellaneous accessories and consumables For ATMOS Record 55, ATMOS C 451 und ATMOS C 36
25
| Accessories and consumables for general surgery
Accessories for DDS DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector DDS-secretion canister, plastic, 1.5 l, autoclavable Height 146 mm, external Ø 166 mm DDS-secretion canister, plastic, 3 l, autoclavable Height 247 mm, external Ø 166 mm DDS-secretion canister, plastic, 5 l,autoclavable Height 396 mm, external Ø 166 mm DDS-canister lid, complete set consisting of: DDS canister lid, DDS canister handle, DDS splash protection, DDS hose adapter set, Ø 6 mm + Ø 10 mm, DDS bacterial filter / oversuction stop, hose holder on DDS canister. DDS-canister lid with gaskets DDS-canister handle, grey Canister handle, blue DDS-splash protection, silicone DDS-hose adapter set, Ø 6 mm + Ø 10 mm DDS-hose holder Single-Docking-Station (SDS) Single-docking-station enables the use of DDS-canisters in connection with ZV / ZD systems. Attention: please order canister with lid separately! Consummables DDS Bacterial filter for DDS secretion canister, 10 pcs. disposable, not autoclavable, Change: daily, with same patient: ca. every 14 days DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 26
REF
❁ 340.0062.0 ❁ 340.0050.0 ❁ 340.0051.0 ❁ 340.0052.0 ❁ 340.0040.0
❁ 340.0053.0 ❁ 340.0055.0 ❁ 340.0326.0 ❁ 340.0056.0 ❁ 340.0057.0 ❁ 340.0066.0 ❁ 320.0640.0
❁ 340.0054.0 ❁ 340.0062.0
MedizinTechnik
Accessories Receptal Receptal®-canister set 2 x 1.5 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 1.5 l, 2 Receptal®-suction bag 1.5 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal®-canister 1,5 l Receptal®-canister set 2 x 2 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 2 l, 2 Receptal®-suction bag 2 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal® canister 2 l Receptal®-canister set 2 x 3 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 3 l, 2 Receptal®-suction bag 3 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal® canister 3 l
REF
❁ 444.0022.0
❁ 310.0221.0 ❁ 444.0023.0
❁ 443.0256.0 ❁ 444.0024.0
❁ 444.0157.0
Included in the delivery of Receptal® packages are the same items as included in the Receptal®-canister sets, apart from the Receptal® holder complete which is replaced by 2 Receptal® holders for one canister.
Receptal® package 2 x 1.5 l
❁ 444.0027.0
Receptal® package 2 x 2 l
❁ 444.0028.0
Receptal® package 1 x 2 l Receptal® package 1 x 3 l Receptal® package 2 x 3 l
Consummables Receptal Receptal® suction bag 1.5 l, not autoclavable, 50 pcs. Receptal® disposable bag 2 l, without integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient Receptal® suction bag 2 l, with integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient Receptal® suction bag 3 l, without integrated overflow protection For tandem hose system, not autoclavable, 50 pcs., change: 1 x per patient. Receptal® suction bag 3 l, with integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient.
❁ 444.0030.0 ❁ 444.0031.0 ❁ 444.0029.0 ❁ 310.0222.2 ❁ 443.0257.0 ❁ 443.0257.2 ❁ 444.0153.0 ❁ 444.0154.0
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 27
| Accessories and consumables for general surgery | Further accessories for general surgery
➀
Further accessories for general surgery ➀ Serres® external canister 1 l Serres® suction bag, 1 l, not autoclavable, 36 pcs. with angled connection Serres® canister 2 l Serres® suction bag 2 l with gelling agent not autoclavable, 22 pcs. Serres® canister 3 l Serres® suction bag 3 l with gelling agent not autoclavable, 20 pcs. Serres® dev. holder Accessories MediVac® Medi-Vac® canister 1 l Standard rail support For disposable system Medi-Vac® 1 l, 1.5 l.
➁
➂
➃
Consummables MediVac® Medi-Vac® suction bag 1 l, not autoclavable, 50 pcs.
General consummables ➁ Suction hose, silicone, Ø 6 mm, L = 2 m, 1 pc Autoclavable at 134 °C, change: after 20 x autoclaving ➂ Suction hose, silicone, Ø 10 mm, L= 2m, 1 pc Autoclavable at 134 °C, change: after 20 x autoclaving Suction hose, disposable, Ø 6 mm, L = 2.10 m, 50 pcs. Change: 1 x per patient Bacterial filter disposable, not autoclavable, change: 1 x per patient Bacterial filter FFG - hydrophobic Bacterial filter disposable, not autoclavable, Change: 1 x per patient ➃ Tissue collector 300 ml, disposable Ø 6 mm, change: 1 x per patient ➄ Collector sieve, disposable 50 ml, change: 1 x per patient Secretion canister lid incl. standard rail holder Socket nipple set consisting of: Double socket nipple, hose reducer, mechanical overflow safety Deposit tray, stainless steel with support for rail system
➄
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 28
REF
❁ 312.0465.0 ❁ 312.0466.0 ❁ 310.0402.0 ❁ 310.0400.0 ❁ 310.0403.0 ❁ 310.0401.0 ❁ 340.0095.0 ❁ 312.0473.0 ❁ 444.0451.0 ❁ 312.0474.0 ❁ 000.0361.0 ❁ 000.0243.0 ❁ 006.0059.0 ❁ 443.0738.0 ❁ 444.0082.0 ❁ 444.0628.0 ❁ 340.0061.0 ❁ 401.0555.0 ❁ 444.0650.0 ❁ 444.0640.0 ❁ 443.0790.0
MedizinTechnik
ATMOS S 201 Thorax / ATMOS E 201 Thorax
The Bülau-drainage with a „brain“
The new generation of mobile thoracic drainage systems including therapy success monitoring 29
ATMOS S / E 201 Thorax
The intelligent thoracic drainage system
ATMOS E 201 Thorax ATMOS S 201 Thorax
Whereas technical developments have progressed at breakneck speed in virtually all other areas of OTs or intensive care and critical care units, thorax drainage procedures are frequently the same as they were 100 years ago - with all the disadvantages that this entails from a modern perspective. Problems: patients experience unnecessarily long periods of immobilisation intensive nursing care risk during transportation within the clinic materials used incur high costs no alarm function in the event of an error etc. The solution: the 2nd ATMOS generation of mobile thorax drainage systems
30
MedizinTechnik
The compact lightweight as a complete solution subsequent therapy success monitoring without unnecessary x-ray complete documentation of vacuum DQG ÀRZ IURP WKH 27 XS WR WKH removal of the drain improved patient safety and therapy success UHGXFHG QXUVLQJ FDUH FRVWV E\ WKH increased capacity of the secretion canister. No constant exchanges of the hoses and canisters the risk of follow-up costs is minimised through rapid mobilisation of the patient improved safety due to easily detec table alarm signaling and connection to the nurse call system eases the burden on the nursing staff
The innovations: More powerful than ever Now with 20 l/min! The new ATMOS thoracic drainage systems ATMOS E 201 Thorax and ATMOS S 201 Thorax with 20 l/min, making them the most powerful electrical drainage systems in the world. 5HDO WLPH ÀRZ PHDVXUHment system 7KH XQLTXH $7026 ÀRZ measurement system enables (real-time) display of WKH DFWXDO ÀRZ FRXQW LQ O PLQ to the second. The nursing staff and doctors are consequently kept LQIRUPHG DERXW WKH ¿VWXOD VWDtus of the patient at all times. Digital therapy control ATMOS S 201 Thorax saves WKH UHDO WLPH ÀRZ PHDVXrement data and shows a progress curve on the colour display. The entire recovery process is thus displayed.
Documentation of the course of treatment The saved data can be read in MS Excel format from an integrated micro SD card and DOORFDWHG WR WKH SDWLHQW ¿OH The course of treatment is thus accessible at all times. Direct vacuum measurement and patient monitoring By means of the ATMOS measuring hose system the set vacuum parameters are measured close to the patient. The „siphon effect“ is excluded because the set parameters are constantly monitored and changes in the status are automatically balanced.. Safe Alarm signalisation The alarm function is designed to make the alarm easily detectable or audible in a noisy environment. The ATMOS S 201 Thorax model may be connected to a nurse call system.
Thorax drainage system
Max. 20 l/min
ATMOS E 201 Thorax
ATMOS S 201 Thorax
z
z
ATMOS disposable container system
z
z
Battery operation
z
z
5HDO WLPH ÀRZ PHDVXUHPHQW
z
z
Flow history
z
Data export via SD card
z
Monitoring function
z
z
Connection to SRS
z
Graphic display
z
z
Colour display
z
z available
|
not available 31
ATMOS S / E 201 Thorax
ATMOS S / E 201 Thorax Mobility is the key
Easy and safe operation
Secretion canister
Connection for secretion hose
Sealing caps for sealing the pop off valve and the secretion hose connection
2 litre secretion chamber with spill over function
Container system for ATMOS E 201 Thorax and ATMOS S 201 Thorax The secretion container different from others - offers maximum safety and mobility for the patient.
32
The very sturdy container has - apart from the spacious secretion chamber with a capacity of 2 litres - an integrated water lock.
The enclosed sealing caps enable safe and hygienic disposal.
MedizinTechnik
Display (graphic mode)
Pop off valve
SD card status
Âż OOHU IRU ZDWHU ORFN
Patient number Current measured vacuum parameter at the patient
Battery charging status
Hydrophobic EDFWHULDO ¿ OWHU ZLWK UHOLDEOH RYHUÀ À RZ protection Vacuum scale
Water lock
Flow value scale H[WHQW RI Âż VWXOD
Time line IURP WKH Âż UVW PLQXWH up to 12 days)
Display ATMOS S 201 Thorax (Graphic mode) Real-time Flow Measuring System:
Digital therapy monitoring:
Documentation:
Direct vacuum measurement
Makes it possible to measure WKH FXUUHQW À RZ SDUDPHWHUV LQ l/min with to-the-second precision (real-time). This means that care personnel and physicians are informed DERXW WKH SDWLHQWœV ¿ VWXOD status at all times.
Data storage from the UHDOWLPH À RZ PHDVXUHPHQW readout on the colour display as progression curve. Therefore the progression of healing can be shown without JDSV IRU WKH ¿ UVW WLPH
Via an integrated SD card, the stored data can be output in Excel format and assigned WR WKH SDWLHQW Âż OH 7KLV PDNHV it possible to trace the progression of treatment at all times.
Through the ATMOS measuring tube system, the vacuum parameter is measured directly at the patient. The risky siphon effect is excluded. Well-thought-out alarm functions and the connection to a nurse call system (ATMOS S 201 Thorax) facilitate daily work in clinics.
33
| Thorax drainage | ATMOS E 201 Thorax / ATMOS S 201 Thorax
ATMOS S 201 Thorax / ATMOS E 201 Thorax
Digital thoracic drainage now with 20 l/min suction performance real-time flow measuring system
digital control of the therapy monitoring
direct vacuum measurement at the patient secure alarm signalling 2 l capacity
Integrated water lock with bacterial filter and oversuction protection
ATMOS E 201 Thorax / ATMOS S 201 Thorax
ATMOS E 201 Thorax Mobile thoracic drainage system of the ATMOS "E-class". Suitable for transport within the hospital and to accompany the patient from the operating room to the end of therapy, Fully electronic monitoring, real-time flow measurement, alarm function, ergonomic monochrome display. Technical data: Pump performance: 20 l/min ± 4 l/min, noise level: max 39 dB (A) 1m (acc. to ISO 7779) dimensions (H x W x D): 366 x 250 x 168 mm
REF ❁ 312.1100.0
Included in delivery: basic unit, micro SD card, carrying strap, mains cable, operating instructions, hose clamp
ATMOS S 201 Thorax Mobile thoracic drainage system of the "S-class". Suitable for transport within the hospital, and to accompany the patient from the operating room to the end of therapy. Fully electronic monitoring, realtime flow measurement, flow history, data export via SD card, alarm function (can be connected to a nurse call system), ergonomic colour display. Technical data: Pump performance: 20 l/min ± 4 l/min, noise level: max 39 dB (A) 1m (acc. to ISO 7779) dimensions (H x W x D): 366 x 250 x 168 mm Included in delivery: basic unit, micro SD card, carrying strap, mains cable, operating instructions, hose clamp
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 34
❁ 312.1000.0
MedizinTechnik
➀
Accessories ➀ Universal bracket Bracket for fastening the ATMOS S 201 Thorax / ATMOS E 201 Thorax on the patient bed, standard rail, wheelchair, tripod, etc Carrying bag for canister Carrying bag for the transport of the canister when using it as gravity drainage. With carrying strap, infinitely variable, 2.5 cm wide. Micro SD card Consumables ➁ OT-Set for ATMOS E/S 201 Thorax consisting of: 10 canisters, 10 hoses (steril) Hose system for ATMOS E/S 201 Thorax, 180 mm length, sterile, for connection to secretion container, REF 312.1150.0 2 l secretion jar, sterile, 10 pcs.
REF
❁ 312.1160.0 ❁ 312.1005.0 ❁ 312.2021.0 ❁ 312.1031.0 ❁ 312.1170.0 ❁ 312.1150.0
➁
Technical data
Operation modes Noise level Voltage
Dimensions (H x W x D) Weight
Classifications Capacity of suction
ATMOS S 201 Thorax
ATMOS E 201 Thorax
Continuous operation with network supply, min. 60 min. at 15 l/min of continuous suction max. 39 dB (A) (acc. to ISO 7779) 100 ... 240 V~ 50/60 Hz 366 x 250 x 168 mm
3.6 kg including empty container
protection type: IPX0; protection class: II; Class: IIa (in accordance with Appendix IX of the Directive 93/42/EEC)
The stated technical data are valid at the moment of printing, and are subject to change!
16 l/min ± 4 l/min
35
Radiofrequency surgery | Application information MedizinTechnik
The problem of previous surgical methods
Radiosurgical interventions with the ATMOS RS 221 Lid plasty Rhinoplasty Epilation Facelift Otoplasty
Excision, Superficial ablation
Mammaplasty
Dermatoplasty
Abdominal plasty
ATMOS RS 221 The Innovation!
36
Aesthetic and plastic surgeons wish – with regard to the patient – to operate with the best methods. Incisions with a scalpel are usually performed with traction and pressure, in doing so the tissue can slip especially in the case of soft or thin skin areas – a perfect aesthetic result is almost impossible. Incisions with laser may damage the surrounding tissue due to the extreme impact of heat – a longer and painful wound healing may be the result.
Is there a better method which is even more favourably-priced? The radiofrequency surgery offers new possibilities and has none of the aforesaid weaknesses. The advantages are the perfect results and the simplicity of the method. More and more plastic surgeons can no longer imagine a surgical intervention without radiowaves – for experienced doctors with radiosurgical systems the advantages compared to the other methods like scalpel, laser or HF surgery are indisputable. Less impact of heat on the tissue speeds up the healing process and has a positive influence on the post-operative well-being. The incisions are smooth without the tissue being squeezed. The incision with the selfsterilizing radiofrequency electrode improves the haemostasis and results in an almost scarless wound healing.
Radiofrequency surgery – The revolution is called “cold” incision
A new dimension of precision Thanks to an innovative technology the ATMOS RS 221 enables incisions without pressure and traction which result in smooth incisions which heal quickly and are considerably less painful. Minimized scarring is the result of less cell damage. Why radiofrequency surgery? There is no damage of the surrounding tissue due to less lateral heating during radiofrequency surgery. This is an essential advantage compared to kHz devices: less tissue necrosis and minimized scarring – thanks to the unexcelled precision even the first incision through the cuticle is now possible with a MHz device! With the new method the histological examination of excised tissue is now possible up to the tissue edge. The ATMOS RS 221 is operated with a frequency of 2.2 MHz because over 3 MHz there could be safety critical antenna effects, and still the medical result is not improved. Radiofrequency surgery versus laser Apart from the fact that the price for laser equipment is ten times more expensive than for the ATMOS RS 221 the applied laser beam develops tissue damaging heat which may cause damage to the surrounding tissue – burnt skin around the wound edges and increased scarring may be the result. Thanks to radiofrequency even skin burning in the case of wetness at the neutral electrode is no longer possible – an important advantage in pediatric surgery. Another important advantage for the OT staff is the reduced laser smoke and herewith the reduced infection risk!
In combination with the ATMOS smoke evacuation system AtmoSafe this adverse effect could be eliminated completely. The multifunctional device for many areas of application Thanks to its invaluable advantages the ATMOS RS 221 radiofrequency surgery device is used mostly for plastic surgery e.g. eyelid lift: with current surgical methods, using a scalpel, laser or electrosurgery, the surgical result in the case of fine skin is insufficient. But even other interventions like rhinophyma or the endoscopic eyebrows lift, hair transplantation, removal of tumours etc. benefit from the use of the ATMOS RS 221. Extensive surgical interventions e.g. mammaplasty, dermatoplasty and abdominal plasty can also be easily performed. 3 operation modes, 3 outlets With the ATMOS RS 221 the surgeon has three different operation modes at his disposal: Cutting (Mono Cut) Cutting and monopolar coagulation (Mono Coag) Coagulation and bipolar coagulation (Bipol Coag) Thanks to the comprehensible symbols the operation of the device is easy – the colour-coded electrodes enable an easy selection of the respective outlet. Without any changeover the surgeon may decide to operate with either tool holder or foot switch Please request therefore alsoour information-DVD: Phone: +49 7653 689-374 ApplicationSolutions@atmosmed.com
37
ATMOS RS 221
ATMOS RS 221
Cutting and coagulation with maximum precision! With the radiofrequency surgical device ATMOS RS 221 ATMOS has added a top-class electrosurgical device to the product portfolio in the business range surgery. During an incision with a scalpel the skin is tightened, the incision itself requires pressure. The result: Imprecise transections, especially in the case of skin unevenness. In case incisions are carried out with conventional HF surgical devices or with laser instead of a scalpel quiet often the result is carbonized wound edges with a delayed wound healing and increased scarring. With the ATMOS RS 221 these disadvantages are eliminated. The incision – even the first incision through the epidermis – is now possible with extremely high precision
38
without traction and pressure. There is no thermal damage to the surrounding tissue and therefore, the wound healing and the scarring are minimized. The consequence is a perfect aesthetic result. With the use of the frequency range of 2.2 MHz tissue is only vaporised where the cutting electrode is in contact with the tissue. The resistance of the tissue prevents the propagation of radiowaves and therefore also a corbonation of the lateral tissue. ATMOS offers a wide range of accessories for the ATMOS RS 221 e.g., electrodes for the incision, coagulation and ablation. For particular safety in the OT the combination of the ATMOS RS 221 and the smoke evacuation system AtmoSafe is perfect.
MedizinTechnik
MONO CUT Always the perfect incision performance for every type of tissue
Symbol buttons Left: Symbol for operating mode Right: Symbol for device type acc. to EN 60 601-1 Below: Symbol for neutral electrode (illuminates in case of malfuction)
MONO COAG For the smooth coagulation with definable depth effect Set of electrodes
BIPOL COAG Safe bipolar coagulation
D
DV
39
| HF- and Radiosurgery | ATMOS RS 221
ATMOS RS 221
Basic equipment
Disciplines: Aesthetic plastic surgery
General and reconstructive surgery Dermatology OMS ENT
Gynaecology
Precision
Aesthetic result
ATMOS quality and service Price-performance ATMOS RS 221
ATMOS RS 221 radiosurgery system 2.2 MHz 4 operating modes: cutting, coagulation-cutting, monopolar-coagulation, bipolar-coagulation, automatic switch of outputs: cutting/coagulation alternatively via handpieces or foot switch. Memory function for storing the last used values. Technical data: Cutting performance max. 100 W, coagulation performance max. 90 W, Standard ATMOS-, Martin-, Berchtoldconnections Included in delivery: basic unit, mains cable, maintenance book, operating instructions
Technical data
ATMOS RS 221
Dimensions (H x W x D)
138 mm x 285 mm x 230 mm
Voltage Weight
Classifications Rated frequency Fuses
Output voltage
Working frequency
Max. coagulation performance: Cutting performance Colour
230 V~
4 kg, accessories plus 1.8 kg
protection class: I; degree of protection: type BF; defibrillationproof; class IIb (acc. to appendix IX, directive 93/42/EEC) 50 / 60 Hz
2 x T 1,6 A / H at 230 V~, 2 x T 3,15 A / H at 115 V 500 V max. top level output voltage 2.2 MHz
max. 90 Watt at 1 kOhm max. 100 W at 1 kOhm
grey-white (RAL 9002) / dove-blue (RAL 5014)
The stated technical data are valid at the moment of printing, and are subject to change!
40
REF â? 506.5800.0
MedizinTechnik
Accessories for ATMOS RS 221
ATMOS RS 221 monopolar accessories set autoclavable at 134 °C consisting of: handle, yellow, cutting (for 1.6 mm electrodes), handle, blue, coagulating (for 1.6 mm electrodes), standard set of electrodes (41, 43, 44, 45, 46, 47, 48), neutral electrode with rubber fixation, connection cable for neutral electrode.
➀
➁
ATMOS RS 221 bipolar accessories set ➀ autoclavable at 134 °C consisting of: bipolar tweezers, short, straight, L = 110 mm, width of the tip 0.5 mm, foot switch with 2.5 m cable, bipolar cable, L = 2.5 m. ➁ Handle for cutting, yellow for 1.6 mm electrodes, cable length 2.5 m, autoclavable ➂ Handle for coagulation, blue for 1.6 mm electrodes, cable length 2.5 m, autoclavable Neutral electrode , 168 x 112 mm (185 cm²) cable length 0.5 m, autoclavable up to 134 °C (at least 75 x) Connecting cable for neutral electrode Rubber bandage for neutral electrode, L = 0.5 m Foot switch for grip without a release button, cable L = 2.5 m Bipolar cable, L = 2.5 m, autoclavable (at least 300 x) ➃ Bipolar tweezers, short, straight, L = 110 mm With of the tip 0.5 mm
REF ❁ 506.5850.0
❁ 506.5860.0
❁ 506.5851.0 ❁ 506.5852.0 ❁ 506.5853.0 ❁ 506.5854.0 ❁ 506.5855.0 ❁ 506.5861.0 ❁ 506.5862.0 ❁ 506.5863.0
➂
➃
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 41
| HF- and Radiosurgery | Accessories for ATMOS RS 221
d
e f
g h
c
i
j
Consumables for ATMOS RS 221 ➀ Self-adhesive disposable electrodes Size 104 x 215 mm (for adults) Included in delivery: 50 pcs.
➁ Cable for self-adhesive disposable electrode, length 3 m With plug for the ATMOS RS 221 and clamp connection with twin bolt to the single-use neutral electrode, autoclavable
❁ 506.5877.0
➂ Special electrode for Uvulopalatoplasty Teflon coated, for safe and gentle removal of the uvula and the soft palate. To be used for chronic snorers. Overall length: 100 mm
❁ 506.5886.0
➃ Cutting ENT needle electrode (extra long), #32 Flexible shaft, L = 100 mm, fine wire
❁ 506.5881.0
➄ Coagulation ENT ball-shaped electrode (extra long), #34 Flexible shaft, L = 100 mm, Ø ball 2,3 mm
❁ 506.5883.0
➅ Cutting ENT loop electrode (extra long), #35 Flexible shaft L = 128 mm, Ø loop 9 mm, super-fine wire
❁ 506.5882.0
➆ Coagulation-electrodes, pointed needle electrode, #36 Coated and bent electrode for coagulation of the lingual tonsils and the submucous UPP; also very suitable for the preparation of fat tissue. L = 105 mm, length of needle = 18 mm (12 mm isolated)
❁ 506.5884.0
➇ Multi-tip electrode, with spare wire, #41 with adjustable wire, for depth control (2 pcs.), wire 0.2 mm
❁ 506.5870.0
Included in delivery: 1 pc.
Included in delivery: 2 pcs.
Included in delivery: 2 pcs.
Included in delivery: 2 pcs.
Included in delivery: 1 pc.
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 42
REF
❁ 506.5878.0
MedizinTechnik
c
d e f g
h
i
j
k
➀ Cutting-electrode, round loop, Ø 13 mm, #43
❁ 506.5871.0
➁ Cutting-electrode, round loop, Ø 7 mm, #44
❁ 506.5872.0
➂ Cutting-electrode, rhombical, #45 leg length 7 mm
❁ 506.5873.0
➃ Cutting-electrode, triangle electrode, # 46 leg length 7 mm
❁ 506.5874.0
➄ Coagulation-electrode, thick needle-electrode, #47 needle Ø = 1.5 mm, needle length 1.5 mm
❁ 506.5875.0
➅ Coagulation-electrode, ball-shaped-electrode, Ø ball 2 mm, # 48
❁ 506.5876.0
➆ Electrode for the nasal radioconchotherapy, #52 Bayonet-shaped, total length = 155 mm, length of needle = 26 mm (10 mm isolated), blue shaft
❁ 506.5885.0
➇ Bipolar needle electrode (puncture electrode), # 03 For volume reduction of the nasal concha. Bent on the rear, isolated needles, ergonomic plastic handle. Total length: 188 mm, needles: 16 mm, isolation: 6.5 mm, angled after 97 mm. Angle: 20 degree, autoclavable up to 134°C
❁ 506.5888.0
➈ Bipolar needle electrode (puncture electrode, bent at the top), # 04 For volume reduction of the soft palate and the lingual tonsils. Bent in front, isolated needles, ergonomic plastic handle, total length: 193 mm, needles: 19.5 mm, isolation: 9.5 mm, bent after 169 mm, angle: 55 degree, autoclavable up to 134°C
❁ 506.5887.0
Included in delivery: 2 pcs. Included in delivery: 2 pcs.
Included in delivery: 2 pcs.
Included in delivery: 2 pcs.
Included in delivery: 2 pcs. Included in delivery: 2 pcs.
Included in delivery: 1 pc.
Included in delivery: 1 pc.
Included in delivery: 1 pc.
Unless otherwise specified all electrodes are autoclavable and therefore reusable. For detailed information please see the operating instructions!
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 43
Smoke evacuation | AtmoSafe MedizinTechnik
AtmoSafe The most powerful smoke evacuation suction system!
44
No laser or HF surgery without smoke evacuation.
AtmoSafe
For the safe HF- and Laser surgery! ATMOS has introduced a smoke evacuation system for the OT – the AtmoSafe – a device which is used mainly in the laser and aesthetic surgery. Electrosurgical cutting and coagulation develop toxic fumes and build up unpleasant smells in the operating field - an obscured view and health risks are the result. The smoke evacuation system AtmoSafe protects both staff and patients from these toxic fumes, to the extent that doctors have a clear view in the OT, it prevents unpleasant smells, eliminates airborne viruses and carcinogenic substances. This cannot be done by a usual surgical suction device. The advantage of the AtmoSafe is, that it is almost noiseless and very economical to run due to the special ULPA filters.
Suction can be made available as and when required with the automatic activation of the device. ATMOS grants 6 years guarantee on the brush-free blower. Thanks to the unique combination of the special gas filter with the ULPA filter, staff and patients are also protected from papilloma viruses, ammoniac emissions and hydrogene cyanide vapours. ATMOS also offers a wide range of consumables for the AtmoSafe e.g. suction funnel, suction cannulae, prefilter and a standard rail with the relevant pivot mounted arm.
45
AtmoSafe MedizinTechnik
Main filter unit
Funnel
measures the airflow of the filter and defines the filter life, which is normally more than 35 hours. It consists of ULPA filter, three activated carbon filter layers and a gas filter.
for sucking off smoke gas.
Pre-adjustments
Trolley
The value for operation suction, basic suction and the follow-up time are individually adjustable. By pressing the scroll button the requested parameter to be adjusted, is selected.
for the mobile use.
Handling
Clip-on handle
Start button, manual Stop button, manual
REF 445.0063.0
Suction performance
Pre-filter (HEPA)
With 650 l/min noxious smoke gas is sucked off.
for a longer service life of the main filter
Filter life indication The indication of the filter life gives an overview on the actual filter status.
46
REF 000.0687.0
REF 950.0200.0
for slim-line handpieces
REF 445.0044.0
| Smoke evacuation | AtmoSafe MedizinTechnik
AtmoSafe
User package and accessories The smoke evacuation system for electro and laser surgery!
Creates a clear view in the operating field Prevents unpleasant smells
Removes airborne particles, viruses, gases, and carcinogenic substances Directly from the manufacturer!
AtmoSafe
AtmoSafe OT set Microprocessor-controlled suction unit for removing and filtering surgical smoke, including internal synchronous activation (ISA), automatic shut-down, filter control, and electronically controlled, brushless blower. Technical data: Pump performance: up to 650 l/min, Dimensions: (H x W x D): 210 x 410 x 370 mm
REF ❁ 445.0075.0
Included in delivery: basic unit, operating instructions, mains cable, Main filter device (ULPA), Prefilter set (HEPA), Hose Ø 22 mm, L = 2.10 m (not autoclavable), Hose Ø 22 mm, L = 2.10 m (50 x autoclavable), extraction tube, suction funnel, hose connector Ø 22 mm to Ø 22 mm, hose connector Ø 22 mm (M) to Ø 10 mm (M), hose connector Ø 22 mm (F) to Ø 10 mm (M), Joint arm (with 3 joints, stretched length approx. 1.3 m), 5 hose holders (hose Ø 22 mm), standard rail set (25 x 10 mm / 315 mm for lateral fixation)
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 47
| Smoke evacuation | AtmoSafe
➀
➁
➂
Accessories for AtmoSafe Hose support for air hose inserted in standard rail,(stainless steel), Ø 22 mm ➀ Foot switch ➁ Foot switch (explosion-proof for OT) IPX8, with holding plate Joint arm with 3 joints for fixation to standard rail autoclavable, stretched length approx. 1.3 m, with 5 hose supports for hose Ø 22 mm Standard rail set Dimensions: 25 x 10 mm / 315 mm for internal fixation to AtmoSafe ➂ Trolley with table top and electrically conductive castors, 1 drawer, Dimensions (H x W x D) 800 x 512 x 550mm colour: RAL 7035 (light grey), Handles in RAL 5003 (sapphire-blue) ISA-power cord 2 m with non-heating plug and non-heating socket for device coupling ISA-power cord 40 cm with non-heating plug and non-heating socket for device coupling Interlink cable interface to laser- or HF-surgery Trolley 850 consisting of: Base with ESD-castors (front castors lockable) deposit board with handles drawer (to be arranged in any position) Dimensions (H x W x D): 85 x 55 x 64 cm Information brochure: "Smoke by-products in laser and HF surgery"
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 48
REF
❁ 445.0066.0 ❁ 445.0061.0 ❁ 445.0068.0 ❁ 445.0060.0 ❁ 445.0064.0 ❁ 445.0065.0
❁ 008.0800.0 ❁ 008.0806.0 ❁ 445.0073.0 ❁ 950.0200.0
MedizinTechnik
➀
➁
➂
Consumables for AtmoSafe ➀ Main filter device (ULPA 99,9999% @ 0,01m / 3-steps gas filter) Change: after approx. 150 patients ➁ Pre-filter (HEPA) with connections Ø 22 mm (M/W), sterile, not autoclavable, 50 pcs., to be used for laser ablations Change: 1 x per patient Air suction handle for smoke-evacuation surgery handles, clip-on handle, air hose Ø 10 mm, L = 2,5 m, 25 pcs., Change: 1 x per patient ➂ Funnel flattened on one side, made of PP with connection for Ø 22 mm, autoclavable up to 134 °C, Change: after 50 x autoclaving Suction tube for suction hose Ø 22 mm, autoclavable up to 134 °C Change: after 50 x autoclaving Air hose Ø 22 mm, L = 2.10 m disposable, not autoclavable, made of E.V.A. Change: 1 x per patient Air hose Ø 22 mm, L = 2.10 m multiple applicable, autoclavable up to 132° C, made of Hytrel, Change: after 50 x autoclaving Air hose Ø 22 mm, L = 2.70 m multiple applicable, autoclavable up to 134° C, made of Hytrel, connecting sockets made of silicone Change: after 50 x autoclaving Air hose, internal Ø = 10 mm, L = 1.8 m autoclavable up to 132 °C, made of hytrel, connecting sockets made of silicone, Change: after 50 x autoclaving ➃ Hose connector, straight, Ø 22 mm (m) to Ø 22 mm (m) ➄ Hose connector, straight, Ø 22 mm (m) to Ø 10 mm (m) ➅ Hose connector, straight Ø 22 mm (f) to Ø 10 mm (m)
REF
❁ 445.0040.0 ❁ 445.0044.0 ❁ 445.0063.0 ❁ 000.0687.0 ❁ 445.0055.0 ❁ 005.0200.0 ❁ 005.0203.0 ❁ 005.0201.0 ❁ 005.0204.0 ❁ 000.0683.0 ❁ 000.0689.0 ❁ 000.0688.0
➃
➄
➅
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 49
| Smoke evacuation | AtmoSafe
AtmoSafe
Basic unit
Creates a clear view in the operating field Prevents unpleasant smells
Removes airborne particles, viruses, gases, and carcinogenic substances Directly from the manufacturer!
AtmoSafe
AtmoSafe - Basic unit Microprocessor-controlled suction unit 230 V~ for removing and filtering surgical smoke, including internal synchronous activation (ISA), automatic shut-down, filter control, and electronically controlled, brushless blower Technical data: Pump performance: up to 650 l/min, Dimensions: (H x W x D): 210 x 410 x 370 mm
REF ❁ 445.0000.0
Included in delivery: basic unit, operating instructions, mains cable, Main filter device (ULPA), Prefilter set (HEPA), Hose Ø 22 mm, L = 2.10 m (not autoclavable), Hose Ø 22 mm, L = 2.10 m (50 x autoclavable), extraction tube, suction funnel, hose connector Ø 22 mm to Ø 22 mm, hose connector Ø 22 mm (M) to Ø 10 mm (M), hose connector Ø 22 mm (F) to Ø 10 mm (M),
Technical data
AtmoSafe basic device
Operating time
Continuous operation
Noise level
Power consumption Voltage
52 dB (A) @ 1m (acc. to ISO 7779) approx. 400 W
AtmoSafe Europe: 230 V~ 50/60 Hz; AtmoSafe World switchable: 100 V~ 50-60 Hz or 120 V~ 50-60 Hz or 230 V~ 50-60 Hz
Dimensions (H x W x D)
210 x 410 x 370 mm (without filter); 420 mm (with filter)
Classifications
protection class (EN 60601-1): I; degree of protection: type CF defibrillator protected; protection category: IPX 0; OT-Foot switch: IPX8; Office-Foot switch IPX1; class I; (acc. to appendix IX, directive 93/42/EEC)
Weight
Appliance air flow with 1.8 m hose
14 kg
Controlled 650 l/min ±10%; Turbo up to 800 l/min free blower flow 1600 l/min
The stated technical data are valid at the moment of printing, and are subject to change!
50
MedizinTechnik
Surgical smoke evacuation for the electrical (HF-laser) incision
aerosols
gases
aggregates
H2O-steam
agglomerates
CO2 /CO
secondary particles
NH3 / HCN / H2S
primary particles vapours droplets tissue residues
volatile organic compounds
tissue
pyrolysis products with the medical use of laser
PDFURSKRWRJUDSK RI WKH Âż OWHU VXUIDFH showing deposited contaminants
The situation: Electrosurgical devices and lasers for the coagulation of tissue are nowadays part of the standard procedure and operating processes can no longer be imagined without these instruments. Arising problems: Unfortunately these surgical inventions are often accompanied by considerable disadvantages. The application of electrosurgery leads to the formation of toxic gases, harmful aerosols and transmission of human viruses to the endangering of health of both patients and operating personnel. The formation of smoke also leads to sight obstruction in connection with unpleasant odours. 7KH SUHVV HYHQ UHSRUWHG WKDW IRU WKH ¿ UVW WLPH ODU\QJHDO SDSLOORPDWRVLV KDV EHHQ UHFRJQLVHG DV DQ RFFXSDWLRQDO GLVHDVH RI nurses working in operating theatres. A high risk of disease transmission has been proven several times during the removal of papilloma and condyloma and the resulting infectiousness due to laser fumes. Hence laser fume extraction is indispensable for the protection of the operating personnel. (Source: Laryngo-Rhino-Otology 2003; 82: page 790-793 – Georg Thieme Verlag Stuttgart) To meet these requirements, the implementation of smoke suction extraction systems during treatment involving lasers or electrosurgical instruments is now prescribed in the USA and in many parts of Europe. This trend is proceeding around the world. ATMOS provides the solution: With application of the AtmoSafe the operating personnel are supplied and protected with an effective, economic and medically reliable smoke extraction unit. Unrestricted safety for patients and personnel in the operating theatre is now guaranteed! This is accomplished by means of the flow rate of 650 l/min – equivalent to 10 times the capacity of the most powerful surgical suction extraction.
The use of a smoke evacuation system to prevent damage to health is an international standard of the health and safety at work guidelines and is urgently recommended for your safety by: Â’ Â’ Â’ Â’
NBOSH National Board of Occupational Safety and Health, Schweden NIOSH National Institute for Occupational Safety and Health, USA OSHA Occupational Safety and Health Administration, USA ANSI American National Standard for the Safe Use of Lasers in Health Care facilities, USA
51
Smoke evacuation | AtmoSafe
Information brochure smoke by-products
1. Is normal operating theatre ventilation adequate for evacuating smoke? No, the rate of air circulation in the room - up to 24 x volume/hour - is not sufficient to evacuate locally generated aerosols and gases; the user is still exposed to dangerous laser smoke. 2. Is a normal room suction system (a central vacuum) not good enough? No, the rate of room suction in an operating theatre is too low, at 30-40 l/min. Research has shown that a minimum of 400-600 l/min. is required in the operating field. 3. How high is the risk of becoming infected from biological substances during an operation? Research is currently being undertaken to ascertain the degree of danger that exists from using different lasers and electrosurgical instruments. It has been proven that infectious particles can reach theatre staff and thereby create an acute risk of infection via the mucous membranes and respiratory tracts. 4. Are the particles generated during an operation really dangerous? Airborne viruses such as papilloma viruses, proteins such as prions (BSE pathogens) and other airborne bacteria and funghi are dangerous substances which can lead to direct infection. 5. Do surgical face masks help protect the operating staff? No, surgical face masks offer theatre staff no protection against airborne particles. These masks were designed to protect patients from droplet infections emanating from the operating team. Up to 25 % of the air inhaled in gets through the mask. 6. Are there other reasons for carrying out localised smoke evacuation, apart from the risk of infection? The use of local smoke evacuation, when carried out during endoscopies, minimally invasive surgery and partially open and closed body cavities, gives optimum visibility.
52
Extracted by: „Smoke-by products in the laser and HF surgery“ An information brochure for staff and patients. Please request our information brochure: Phone: +49 7653 689-374 ApplicationSolutions@atmosmed.com
7. How do doctors react to smoke evacuation devices? Smoke evacuation enjoys a high level of acceptance among medics, as they no longer have to contend with an obscured view in the operating field. 8. What effects do particles and gases have on the patient? During laparoscopies in particular, toxic gases diffuse into the patient‘s bloodstream. Small airborne particles in this VPRNH PHDVXULQJ IURP WR P FDXVH RFXODU and upper respiratory tract irritation. 9. Is there a risk to the patient? Medical staff should be aware of the risks to the patient from laser use and diathermic smoke generation during an operation. Some of the smoke inside a closed abdominal cavity can lead to an increase in methaemoglobin content, which reduces the capacity of body tissue to absorb oxygen. 10. Does the suction device have to be operated separately? No, the suction device runs in the background; assistant theatre staff do not need to devote any resources to operating it. The smoke evacuation unit is activated automatically when needed. 11. How high are the running costs of local smoke evacuation? The operating costs of the filter system are less than 1 Euro per surgical procedure and the filter unit has a life of up to 52 hours, depending on flow. 12. Do lasers deactivate dangerous airborne viruses? No, research on retroviruses has shown that infectious viruses and constituents of virus DNA are carried in laser smoke. So it is possible to be infected, for example, by papilloma viruses in the laser smoke.
MedizinTechnik
ATMOS ZV 60 / ATMOS ZD 60 Vacuum regulator and suction systems for central vacuum supply and central compressed air supply
For anaesthesia and intensive care – the perfect system solution for demanding users.
53
ATMOS ZV / ZD 60
ATMOS ZV 60 / ATMOS ZD 60 You are familiar with the situation: You need a reliable and powerful suction system!
Bedridden patients are treated by the in-house vacuum system during their hospital stay. The vacuum supply is adequate but it must be reliably controlled. The solution: ATMOS, as one of the leading manufacturers of suction units worldwide, has been looking into this matter and can now present you with the ATMOS ZV 60 and ATMOS ZD 60. This system solution stands for safety due to - Perfect meter-reading - Suction control at a glance - The cut-off valve for immediate interruption of vacuum supply
54
Furthermore, the single docking station is suitable for economically designed treatment processes. The secrete jars can be used for both, the central vacuum system and in portable suction systems. An advantage is that the nursing staff do not have to be instructed in the use of different jar systems and that the handling of this system is very simple and convenient.
MedizinTechnik
ATMOS ZV 60 / ATMOS ZD 60
Max. flow, 55 l/min (+/-5 l) For all applications in the OT and on the ward. The damped vacuum gauge is easy to read and suction is controlled at a glance.
Single Docking Station for connecting the ATMOS DDS containers. By now the approved Direct Docking Stations are also available for connection to the standard rail system (25x10 mm or 30x10 mm).
The multiple-use container system: The direct docking systems from ATMOS! No more cumbersome tube connections.
55
| Suction system for vacuum and compressed air | ATMOS ZV/ZD 60
ATMOS ZV / ZD 60
Central vacuum and compressed air supply
maximum flow 55 l/min (±5 l) perfect meter-reading
suction control at a glance
cut-off valve for immediate vacuum interruption
ATMOS ZV/ZD 60
ATMOS ZD 60 Vacuum suction regulator for the central compressed air connection, with vacuum regulator, vacuum display and stop valve, CPC coupling for connecting hose, device connecting hose NIST EN 739, incl. standard rail support Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure
REF ❁ 320.0800.0
Included in delivery: basic unit, operating instructions
ATMOS ZV 60 Vacuum suction regulator for the central vacuum connection, with vacuum regulator, vacuum display and stop valve, CPC coupling for connecting hose, device connecting hose NIST EN 739, incl. standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure Included in delivery: basic unit, operating instructions
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 56
❁ 320.0750.0
MedizinTechnik
ATMOS ZD 60 SDS-1 set Mobile suction unit for connection to the central compressed air with vacuum controller, vacuum display and stop valve, CPC coupling for connecting hose with NIST EN 739 connection, including standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure
REF
❁ 320.0745.0
Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions
ATMOS ZV 60 SDS-1 set Mobile suction unit for connection to the central vacuum system Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions
ATMOS ZD 60 SDS-2-Set Mobile suction unit for connection to the central compressed air with vacuum controller, vacuum display and stop valve, CPC coupling for connecting hose with NIST EN 739 connection, including standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure
❁ 320.0740.0
❁ 320.0720.0
Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions, stainless steel trolley (with 2 standard rails)
ATTENTION: DDS canister with lid must be ordered separately!
ATMOS ZV 60 SDS-2-Set Mobile suction unit for connection to the central vacuum system
Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions, stainless steel trolley (with 2 standard rails)
❁ 320.0730.0
Please order connecting hoses separately!
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 57
| Suction system for vacuum and compressed air | ATMOS ZV/ZD 60
➀
Accessories for completing the ZV / ZD versions ➀ Trolley Stainless steel frame with plastic castors, dimensions (with castors) H x W x D: 844 x 450 x 435 mm, roller Ø 55 mm ➁ Single-Docking-Station (SDS) Single-docking-station enables the use of DDS-canisters in connection with ZV / ZD systems. Attention: please order canister with lid separately! Hose C 401 ground connection canister Accessories for ATMOS ZD / ZV 60
Connection hoses for vacuum ➂ Connection hose 1.5 m for ZV 60 (DIN adapter) Connection hose 3 m for ZV 60 (DIN adapter) Connection hose 5 m for ZV 60 (DIN adapter)
REF
❁ 320.0450.0 ❁ 320.0640.0
❁ 340.0083.0
❁ 320.0765.0 ❁ 320.0832.0 ❁ 320.0831.0
➁
➂ ➃ Connection hose 1.5 m for ZV 60 (British standard)
❁ 320.0766.0
Connection hose 5 m for ZV 60 (British standard)
❁ 320.0827.0
Connection hose 3 m for ZV 60 (British standard)
❁ 320.0834.0
➃ ➄ Connection hose 1.5 m for ZV 60 (AFNOR connection)
❁ 320.0844.0
Connection hose 5 m for ZV 60 (AFNOR connection)
❁ 320.0823.0
Connection hose 3 m for ZV 60 (AFNOR connection)
❁ 320.0839.0
➄ ➅ Connection hose 1.5 m for ZV 60 (US OHMEDA connection)
❁ 320.0846.0
Connection hose 5 m for ZV 60 (US OHMEDA connection)
❁ 320.0826.0
Connection hose 3 m for ZV 60 (US OHMEDA connection)
➅
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 58
❁ 320.0836.0
MedizinTechnik
➀ Connection hose 1.5 m for ZV 60 (Scandinavian connection)
❁ 320.0843.0
Connection hose 5 m for ZV 60 (Scandinavian connection)
❁ 320.0822.0
Connection hose 3 m for ZV 60 (Scandinavian connection)
❁ 320.0840.0
➀
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 59
| Suction system for vacuum and compressed air | Accessories for ATMOS ZD / ZV 60
Supply hoses for compressed air ➀ Connection hose 1.5 m for ZD 60 (DIN adapter) Connection hose 3 m for ZD 60 (DIN adapter) Connection hose 5 m for ZD 60 (DIN adapter)
REF
❁ 320.0815.0 ❁ 320.0833.0 ❁ 320.0830.0
➀ ➁ Connection hose 1.5 m for ZD 60 (British standard)
❁ 320.0816.0
Connection hose 5 m for ZD 60 (British standard)
❁ 320.0829.0
Connection hose 3 m for ZD 60 (British standard)
❁ 320.0835.0
➁ ➂ Connection hose 1.5 m for ZD 60 (AFNOR)
❁ 320.0845.0
Connection hose 5 m for ZD 60 (AFNOR)
❁ 320.0824.0
Connection hose 3 m for ZD 60 (AFNOR)
❁ 320.0838.0
➂ ➃ Connection hose 1.5 m for ZD 60 (US OHMEDA)
❁ 320.0847.0
Connection hose 5 m for ZD 60 (US OHMEDA)
❁ 320.0825.0
Connection hose 3 m for ZD 60 (US OHMEDA)
❁ 320.0837.0
➃ ➄ Connection hose 1.5 m for ZD 60 (Scandinavian)
❁ 320.0842.0
Connection hose 5 m for ZD 60 (Scandinavian)
❁ 320.0821.0
Connection hose 3 m for ZD 60 (Scandinavian)
➄
Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 60
❁ 320.0841.0
MedizinTechnik
ATMOS Service worldwide
7HFKQLFDO WUDLQLQJ 0DLQWHQDQFH DQG VHUYLFLQJ 6HUYLFH DQG UHSDLU
We offer you complete support so you can care for your patients! 61
MedizinTechnik
Training and instructions Â’ ,QVWUXFWLRQV IRU XVH
Â’ 3URGXFW WUDLQLQJ
The ATMOS product and introductory training courses will clearly and comprehensively prepare your staff for practical operation. We ensure that important knowledge and skills concerning maintenance and care are communicated and if required, this training can be carried out on customer premises.
Introductory training courses for ATMOS products )XQGDPHQWDO HOHPHQWV RI $7026 SURGXFWV DQG V\VWHP DSSOLFDWLRQV $SSOLFDWLRQ LQ FRPSOLDQFH ZLWK XVHU LQVWUXFWLRQV IXQFWLRQLQJ PRGH DXWKRULVHG DFFHVVRULHV RSSRUWXQLWLHV IRU FRPELQDWLRQ ZLWK RWKHU SURGXFWV VDIHW\ IXQFWLRQV FDUH PDLQWHQDQFH DQG K\JLHQH PHDVXUHV SUDFWLFDO H[HUFLVH Confirmation of participation in a course by means of instruction certificate!
Location
Product
Price
Participants
2Q VLWH
6XFWLRQ SURGXFWV1) WDEOH WRS XQLWV1) FKDLUV1) XQLWV1)
$FFRUGLQJ WR DJUHHPHQW
PD[
Target group: 8VHUV RI $7026 SURGXFWV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU (Appoints according to agreement).
Technical product training for ATMOS Products ,QLWLDO WUDLQLQJ LQ XQLW DSSOLFDWLRQ EDVLF WHFKQLFDO NQRZOHGJH RQ WKH XQLW PDLQWH QDQFH LQVSHFWLRQ DQG FDUH K\JLHQH PHDVXUHV WLSV IRU WURXEOH IUHH RSHUDWLRQ UHSDLU ZRUN SUDFWLFDO H[HUFLVH Confirmation of participation in the course by means of certificate!
Location /HQ]NLUFK 2Q VLWH
Duration
Price
Participants
GD\
1)
±
GD\
1)
PD[
Target group: 0HGLFDO WHFKQLFLDQV ZRUNLQJ LQ KRVSLWDOV DQG FOLQLFV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU 3DUWLFLSDQW LV D PHGLFDO WHFKQLFLDQ (Appointment according to agreement).
1)
62
)RU SULFHV DQG VSHFLDO RIIHUV SOHDVH FRQWDFW \RXU ORFDO GHDOHU
z Reprocessing
z Consulting
Our regular training courses dealing with the preparation of suction units provide our partners with the necessary know-how required to prepare ATMOS medical products both functionally and hygienically.
Reprocessing training courses for ATMOS small suction units Reprocessing in accordance with BVMed- und ATMOS guidelines, legal basis (MPG (Medical Product Law), RKI (Robert Koch Institute) technical principles, simple repair work as well as practical exercise. Confirmation of participation in the training course by means of certificate!
Location /HQ]NLUFK 2Q VLWH
Duration
Price
Participants
GD\
1)
Âą
GD\
1)
PD[
Target group: 6HUYLFH WHFKQLFLDQV ZLWK HOHFWUR WHFKQLFDO WUDLQLQJ DQG PHGLFDO WHFKQLFLDQV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU 3DUWLFLSDQW FDQ SURYH WKDW KH VKH SRVVHVVHV HOHFWRU WHFKQLFDO VNLOOV &HUWLILFDWLRQ LQ DFFRUGDQFH ZLWK ,62
The new conference room in the ATMOS Academy
Advice and services all around your ATMOS products Â’ Â’ Â’ Â’
1)
&HUWLILFDWH RI YDOXDWLRQ 9DOXH UHWHQWLRQ UHSRUW &HUWLILFDWH LQ WKH VFRSH RI LQGHSHQGHQW SUHVHUYDWLRQ RI HYLGHQFH 3URMHFW DFFRPSDQ\LQJ DQG DGYLVRU\ DFWLYLWLHV $GYLFH ZLWK UHJDUG WR FOHDQLQJ FDUH DQG ZDWHU K\JLHQH
)RU SULFHV DQG VSHFLDO RIIHUV SOHDVH FRQWDFW \RXU ORFDO GHDOHU 63
MedizinTechnik
Maintenance and inspection We recommend preventive maintenance – because malfunction means downtime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egal requirements to be fulfilled by the treating doctor Safety-related inspections Ä7KH RSHUDWRU RI PHGLFDO SURGXFWV KDV WR DELGH E\ WKH VDIHW\ UHODWHG FRQWUROV SUHVFULEHG E\ WKH PDQXIDFWXUHU DQG LQ DFFRUGDQFH WR WKHLU VSHFLILFDWLRQV DQG JHQHUDO UHJXODWLRQV 7KHVH QHFHVVDU\ PDLQWHQDQFH PHDVXUHV KDYH WR EH SHUIRUPHG ZLWKLQ WKH GHDGOLQH VWDWHG DQG KDYH WKHP LPSOHPHQWHG ³ *HUPDQ UHJXODWLRQ
6HUYLFH
'HVFULSWLRQ
$QQXDO VHUYLFH LV SHUIRUPHG RQ VLWH IUHH RI FKDUJH
$ERXW IRXU ZHHNV LQ DGYDQFH $7026 DUUDQJHV DQ DSSRLQWPHQW ZLWK \RX 7KH KRXUV RI ZRUN DQG WKH WUDYHO FRVWV DUH LQFOXGHG
)XQFWLRQDO FKHFN
$OO WKH IXQFWLRQV RI WKH FRPSOHWH V\VWHP DQG WKH EXLOW LQ PRGXOHV DUH FKHFNHG $Q LQVSHFWLRQ RI DOO WKH PHFKDQLFDO SDUWV LV SHUIRUPHG $OO WKH FDEOHV DQG SOXJ LQ FRQQHFWRUV DUH FKHFNHG
6DIHW\UHOHYDQW FKHFN
6DIHW\ UHOHYDQW FKHFNV LQFOXGLQJ HOHFWULFDO LQVSHFWLRQ DFFRUGLQJ WR † 0HGLFDO 'HYLFHV 2SHUDWRU 2UGLQDQFH DFFRUGLQJ WR ',1 (1
9
9*
9*
)LWWLQJ RI 'XULQJ WKH DQQXDO PDLQWHQDQFH FKHFN ZH RSWLRQV IUHH RI ZLOO UHWUR¿ W RSWLRQV IUHH RI FKDUJH ZKLFK FKDUJH PD\ EH RUGHUHG IURP RXU FDWDORJXH
9*
GLVFRXQW
)RU DOO VSDUH SDUWV DQG MRXUQH\
9
3URORQJDWLRQ RI WKH JXDUDQWHH IRU DQRWKHU \HDU
\HDU LQVWHDG RI D \HDU JXDUDQWHH IRU D PDLQWHQDQFH FRQWUDFW ZKLFK LV PDGH ZKHQ D QHZ $7026 6 LV ERXJKW
9
$GYLFH SHU KHOS ZLWK WHFKQLFDO SUREOHPV LQ DYDLODEOH WHOHSKRQH DQG IUHH RI FKDUJH SHU WHOHSKRQH RU YLD H PDLO H PDLO GXULQJ EXVLQHVV KRXUV
64
$7026 6WDQGDUG
Your advantages: „ 5HGXFHV GRZQWLPHV „ &RQVHUYDWLRQ RI YDOXHV RI \RXU LQYHQWRU\ „ 'LVFRXQWV RQ UHSDLUV DQG QR FDOO RXW IHH „ 4XLFN WURXEOHVKRRWLQJ „ 3URORQJDWLRQ RI ZDUUDQW\ „ 3UHVFULEHG VDIHW\ FKHFN DFFRUGLQJ WR
† 0HGLFDO 'HYLFHV 2SHUDWRU 2UGLDQFH
Reprocessing of small ATMOS suction devices
The reprocessing of ATMOS suction devices is our speciality!
6FRSH 'HYHORSPHQW PDQXIDFWXUH VDOHV DQG VHUYLFH RI PHGLFDO GHYLFHV IRU WUHDWPHQW GLDJQRVWLFV DQG WKHUDS\ LQ FOLQLF SUDFWLFH DQG KRPHFDUH DV ZHOO DV reprocessing of suction devices
:H DUH FHUWLILHG IRU WKH UHSURFHVVLQJ RI VXFWLRQ GHYLFHV DFFRUGLQJ WR (1 ,62 DQG (1 ,62 6HQG \RXU $7026 VXFWLRQ GHYLFH WR RXU VHUYLFH GHSDUWPHQW ZLWK WKH UHPDUN ³UHSURFHVVLQJ´ <RXU GHYLFH ZLOO EH SURFHVVHG HIILFLHQWO\ DQG FRPSHWHQWO\ ZLWK WKH DSSURSULDWH K\JLHQH SURFHGXUH
ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone: +49 7653 689-222 Fax: +49 7653 689-292 Service@atmosmed.de
Our Service team: Eckhardt Stender, Olaf Marx, Michael Weis, Egon Blessing, Christian König, Klaus Bendkowski, Kian Schwuchow (back) Jean-Luc Imhoff, Manuela Schmidt, Claudia Tritschler, Kerstin Wehrle, Winfried Link (front)
65
ATMOS Partners worldwide Around the globe. Around the clock. Anytime.
66
ATMOS Partners worldwide
MedizinTechnik
MedizinTechnik
ATMOS Sales & Service team Managing Director Sales
Sales Manager Germany
Headquarters:
Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch
Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch
Ludwig-Kegel-Str. 12, 14-16, 18
Maik Greiser Phone
+49 7653 689 215
MGreiser@atmosmed.de
Area Sales Manager Ralf Kühnemund France, Benelux, Italy, USA, Canada, Marocco, Tunisia, Algeria, South africa Phone +49 7653 689-311 E-Mail RKuehnemund@atmosmed.de
Area Sales Manager Axel Kanefeyer NE-Europ, Switzerland, Austria, Middel East, China, Egypt Phone +49 7653 689-330 E-Mail
Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch Bernd Schley Sales Phone E-Mail
DGebele@atmosmed.de
Regional Sales Manager Matthias Straub Asia & Ozeanien Phone E-Mail
Region North
Max-Nonne-Str. 45
Jan Carmienke Service North E-Mail J.Carmienke@agh-diagnostics.de
22419 Hamburg/Germany Tel: +49 40 5332 685-0 Rainer Holzem Teamleader Sales North (SI) Phone Mobile E-Mail
Daniel Gebele Great Britain, Spain, Portugal, Latin america
+49 7653 689-355 BSchley@atmosmed.de
Region North
Area Sales Manager +49 7653 689-340
+ 49 4231 936155 + 49 171 7640648 RHolzem@atmosmed.de
Jochen Kaufels Sales representative North (AS) Nordstr. 28a 06862 Dessau-Roßlau Phone +49 34901 947 58 Fax –59 Mobile + 49 160 96367338 E-Mail JKaufels@atmosmed.de
Ulrich Kraut Service Northwest E-Mail UKraut@atmosmed.de
Matthias Wolf Service Northeast E-Mail MWolf@atmosmed.de
Region South Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch Roland Vöstel Teamleader Sales South (SI) Phone +49 7653 689-310 E-Mail RVoestel@atmosmed.de
+60 (3) 6274 7400 MStraub@atmosasia.com
Area Sales Manager Andreas Käfer Sales representative Southwest (SI) Schwaigernerstr. 2 75050 Gemmingen Phone +49 7267 914610 Fax –629 Mobile +49 175 2905410 E-Mail AKaefer@atmosmed.de
Philipp Rellermeier Indien, Asien, Oceania, Central Africa Phone +49 7653 689-325 E-Mail PRellermeier@atmosmed.de
Sales Support Manager
Region South Horst Delling Service Southeast E-Mail HDelling@atmosmed.de
Wolfgang Heiß Sales representative Southeast (SI) Zeisigweg 13 86420 Diedorf-Anhausen Phone +49 8238 958342 Fax –624 Mobile +49 171 3049490 E-Mail WHeiss@atmosmed.de
Julia Schumacher Phone E-Mail
ATMOS MedizinTechnik GmbH & Co. KG Tel. +49 7653 689-222 E-Mail service@atmosmed.de
Business Unit Manager Sales (AS)
AKanefeyer@atmosmed.de
Phone
79853 Lenzkirch
Michael Schindler Sales Manager Germany Phone +49 7653 689 350 Mobile +49 151 11714220 E-Mail MSchindler@atmosmed.de
+49 7653 689-327 JSchumacher@atmosmed.de
Region Middle Luisenstraße 21 53721 Siegburg Georg Grünefeld Teamleader Sales West (SI) Phone +49 2241 1279146 Mobile +49 171 3616181 E-Mail GGruenefeld@atmosmed.de
Region Middle Robert Bach Service West E-Mail
RBach@atmosmed.de
Sven Schlimgen Sales representative West (AS) Phone +49 2241 1461253 Mobile +49 170 7632967 E-Mail SSchlimgen@atmosmed.de
SI = System Integration AS = Application Solutions
67
MedizinTechnik
Your contact person at the parent company in Lenzkirch Business Unit Manager OEM
Business Unit Manager Application Solutions
Business Unit Manager System Integration
Ulrich Jehle Tel. +49 7653 689- 600 UJehle@atmosmed.de
Urich Jehle Phone +49 7653 689-600 UJehle@atmosmed.de
Jรถrg Pahlke Phone +49 7653 689-642 JPahlke@atmosmed.de
Product Manager OEM
Product Manager Suction devices and Drainage systems Simon Wegner Phone +49 7653 689-644 SWegner@atmosmed.de
Product Manager ENT
Product Manager Suction devices and Drainage systems Julian Fitz Phone +49 7653 689-643 JFitz@atmosmed.de
Junior Product Manager ENT
Dominik Birkenmaier Tel. +49 7653 689- 651 DBirkenmaier@atmosmed.de
Jenny M. Doan Phone +49 7653 689-647 JDoan@atmosmed.de
Florian Betz Phone +49 7653 689-641 FBetz@atmosmed.de Product Manager Gynaecology Daniel Notheis Phone +49 7653 689-646 DNotheis@atmosmed.de
The Managing Directors a strong family team Therewith the generation change has been initiated. From left to right:
Maik Greiser Peter Greiser Gerlinde Greiser Frank Greiser
68
MedizinTechnik
Europe
Endovision B.V.B.A.
Dräger Medical Belgium N.V.
Tommy De Saeger
Marc Notez
Arseus Health
Eric Salden
Belgium / Luxembourg
Phone +32 24626211 Fax +32 26095240 E-Mail tommy.desaeger@draeger.com www.draeger.com Belgium / Luxembourg
Phone +32 475 510559 Fax +32 3 8252370 E-Mail Eric.salden@arseus-medical.be www.arseus-medical.be Belgium / Luxembourg
Medical Technic Eng. Ltd.
Seelen Care ApS
Otoplug OY
Phone +32 1640 7010 Fax +32 1640 7066 E-Mail info@endovision.be
Lise von Seelen Weis
Dimitar Konov
Kerkko Penttilä
Bulgaria
Phone +45 70 9742229 Fax +45 70 97401396 E-Mail seelen@seelen-care.dk www.seelen-care.dk Denmark
Phone +358 33 647215 Fax +358 33 647815 E-Mail NHUNNR SHQWWLOD#RWRSOXJ ¿ ZZZ RWRSOXJ ¿ Finland
ATMOS MEDICAL FRANCE
Papapostolou Ltd.
ATMOS Medical Ltd.
Phone +31 359 2 9712845 Fax +31 359 2 8734943 E-Mail konov@mte-bg.com
Julie Siafarika
Nicolas Perusin Phone +33 491 443294 Fax +33 491 443968 E-Mail atmosfrance@atmosfrance.fr www.atmosmed.fr France MedizinTechnik
Phone +30 210 6790000 Fax +30 210 6790100 E-Mail jsiafarika@papapostolou.gr www.papapostolou.gr Greece
David Butchart Phone +44 1489 611 739 Fax +44 1489 611 612 E-Mail david.butchart@atmosmedical.com www.atmosmedical.com Great Britain MedizinTechnik
69
MedizinTechnik
Europe
ATMOS Medical Ltd.
ICEPHARMA
Arnar Adalsteinsson
David Butchart MedizinTechnik
ATMOS ITALIA S.R.L
Matteo Bertoletti
Phone +44 1489 611 739 Fax +44 1489 611 612 E-Mail david.butchart@atmosmedical.com www.atmosmedical.com Ireland
Phone +354 5 204310 Fax +354 5 408001 E-Mail arnar@icepharma.is www.icepharma.is Iceland
Phone +39 02 48402262 Fax +39 02 48402506 E-Mail m.bertoletti@atmosmed.it www.atmosmed.it Italy
INEL Medicinska Tehnika
UAB Biomedika
Pharma-Cos. Limited
Vilko Klindic
Kestutis Liegus
Phone +385 165 20546 Fax +385 165 20966 E-Mail vilko.klindic@inel-mt.hr www.inel-mt.hr Croatia
Phone +370 8 5 2709055 Fax +370 8 5 2709056 E-Mail kestutis@biomedika.lt www.biomedika.lt Lithuania
Vinora d.o.o. Skopje
Entercare BV
MedizinTechnik
Marcel K. Mifsud Phone +356 21 441977 Fax +356 21 441388 E-Mail info@pharma-cos.com www.pharma-cos.com Malta
Tefa-Portanje B.V.
Mirjam Schouten Alexandar Nikolovski Phone +389 2 3177914 Fax +389 2 3177914 E-Mail vinoramk@unet.com.mk www.vinora.com.mk Macedonia
Phone +31 348 420142 Fax +31 348 420142 E-Mail lchoogstraten@entercare.nl www.entercare.nl Netherlands
OrtoMedic AS
Neuroth AG
Morten Hansen Phone +47 67 518600 Fax +47 67 518599 E-Mail mh@ortomedic.no www.ortomedic.no Norway 70
Luc C. Hoogstraten
Karl Osobsky Phone +43 1 5455 013100 Fax +43 1 5455 013500 E-Mail karl.osobsky@neuroth.at www.neuroth.at Austria
Phone +31 348 495 882 Fax +31 348 495 799 E-Mail m.schouten@tefa-portanje.opg.nl http://www.tefa-portanje.nl Netherlands
Medicus App. i Instrumenty Medyczne
Janusz Surma Phone +48 71 3472100 Fax +48 71 3472111 E-Mail jsurma@medicus.wroc.pl www.medicus.wroc.pl Poland
MedizinTechnik
Europe
Medist S.R.L.
ATMOS Medica S.L.
Daniel Romo
Bogdan Niculescu MedizinTechnik
OOO ATMOS Medikal
Andrey Sorokin
Phone +34 902193580 Fax +34 937414672 E-Mail dromo@atmosmed.es www.atmosmed.es Portugal
Phone +40 21 4115003 Fax +40 21 4105446 E-Mail bogdan.niculescu@medist.ro www.medist.ro Romania
Phone +7 495 2580894 Fax +7 495 2580894 E-Mail atmosmed@telsycom.ru www.atmosmed.ru Russia
ATMOS Medical AG
ULTRAMED s.r.o.
Dräger Slovenija d.o.o.
Juraj Varga
Jacky Noll Phone +41 616914151 Fax +41 61 6910992 E-Mail info@atmosmed.ch www.atmosmed.ch Switzerland
MedizinTechnik
ATMOS Medica S.L.
MedizinTechnik
Robert Pristavec
Phone +421 456761318 Fax +421 456761317 E-Mail juraj.varga@ultramed.sk www.ultramed.sk Slovakia
Phone +386 4 561 2263 Fax +386 1 561 2264 E-Mail robert.pristavec@draeger.com www.draeger.com/slovenija Slovenia
HIST Medical s.r.o.
ATMOS Medikal Ltd.
Jaromir Hink
Daniel Romo
Timur Arslan
Phone +34 902193580 Fax +34 937414672 E-Mail dromo@atmosmed.es www.atmosmed.es Spain
Phone +420 737329835
Czech Republic
Phone +90 2165756414 Fax +90 216575635 E-Mail TArslan@atmosmed.de www.atmosmed.de Turkey
ATMOS HÖR-KA KFT.
TAHAT
Costas Papaellinas Org.
MedizinTechnik
E-Mail hist.medical@seznam.cz
Siarhei Shmyk
István Nyitó Phone +36 1 335 6028 Fax +36 1 335 6028 E-Mail inyito@atmosmed.hu www.atmosmed.hu Hungary
MedizinTechnik
Phone +375 17 296 54 99 Fax +375 17 296 39 99 E-Mail tahat@mail.bn.by Belarus
MedizinTechnik
Nicos Mylonas Phone +357 22 863100 Fax +357 22 675136 E-Mail nicos.mylonas@papaellinas.com www.papaellinas.com Cyprus 71
MedizinTechnik MedizinT
North- / South America
ATMOS Inc.
DEWIMED S.A.
Gernd von Dewitz
Ingo Riedl MedizinTechnik
Pablo Guzovsky
Tel. +1 610 351-7221 Fax +1 610 351-6827 E-Mail IRiedl@atmosmed.com www.atmosmed.com USA / Canada
Phone +52 55 56060777 Fax +52 55 56060520 E-Mail gvdewitz@dewimed.com.mx www.dewimed.com.mx Mexico
Phone +55 11 32894600 Fax +55 11 32844484 E-Mail pablo@panmedica.com.br www.panmedica.com.br Brazil
Ferrari Medical Ltd.
Representaciones Médicas „Mary“ S.R.Ltda.
Panadex S.A.
Ronaldo Luiz Ferrari
Mary Tafur
Phone +55 11 3205-6200 Fax +55 11 3205-6211 E-Mail ronaldo@ferrarimedical.com.br www.ferrarimedical.com.br Brazil
Phone +51 1 6140600 Fax +51 1 6140603 E-Mail int.supplier@medicasmary.com www.medicasmary.com Peru
Auditron Argentina S.A.
Auditron Chile
Hugo Wainerman Phone +54 11 43739800 Fax +54 11 43736560 E-Mail info@auditron.com.ar www.auditron.com.ar Argentina
72
Panmédica
Daniel Nocetti Phone +56 22366838 Fax +56 22366877 E-Mail danielnocetti@auditron.cl www.auditron.cl Chile
Ariel Panduro P. Phone +51 223 0412 Fax +51 223 0414 E-Mail ariel@panadex.com www.panadex.com Peru
MedizinTechnik
Africa, Middle East
Egyptian Group Co. S.A.E.
MEDICALEX
S.E.H.L.
Mohammed Ben Sadik
Yazzine Azzouz
Ayman Younis Phone +002 0222687712-13 Fax +002 0222687714 E-Mail ayounis@eggroup-eg.com www.eggroup.com.eg Egypt
Phone +213 21690551 Fax +213 21690551 E-Mail azzouz_medicalex@yahoo.fr
Phone +212 522 200356 Fax +212 522 263988 E-Mail mbensadik@gmail.com
Algir
Morocco
TDW Medical (Pty.) Ltd.
General Business Trading
General Medicals W.L.L
Tahar Somai
Terry Wiegand
K. Sridhar
Phone +27 11 7643438 Fax +27 11 7643438 E-Mail terryw@tdwmed.co.za www.tdwmed.co.za South Africa
Phone +216 71704200 Fax +216 20437417 E-Mail tahar.somai@gbtrade.com Tunisia
Phone +973 17 727600-213 Fax +973 17 728274 E-Mail sridhar.medics@intercol.com www.intercol.com Bahrain
X-Ray Iran Co. Ltd.
DANEL Medical Equipment
Hekmamed
Ori Danel
Mehdi Mohseni
Dr. Naser Tiari
Phone +98 21 66957185 Fax +98 21 66417190 E-Mail info@xrayiran.com
Phone +972 3 6326353 Fax +972 3 7600684 E-Mail ori@danelmedical.com
Phone +218 21 3608493 Fax +218 21 3611339 E-Mail hekmamed@hotmail.com
Iran
Israel
Libya
73
MedizinTechnik
Middle East
SAM MEDICAL CORPORATION.
Technomedics Co. LTD
Nizar S. Al-Kubati
Sami Aggad
Sherif Shehata
Phone +967 4 218111 Fax +967 4 218113 E-Mail info@sammedical-ye.com www.sammedical.com.ye Yemen
Phone +962 6 5532395 Fax +962 6 5533294 E-Mail techno@nets.com.jo Jordan
Phone +974 403 9550 Fax +974 403 9551 E-Mail sherif.shehata@aamalmed.com www.ebnsina.com.qa Qatar
Central Circle Co.
Ibn-Sina Pharmacy LLC
Intermed PAL.
Hani Hamad
Ramesh Prakash
Omer Fittiani Phone +965 2 411748 Fax +965 2 411758 E-Mail cencico@qualitynet.net
Phone +968 24822108 Fax +968 24813472 E-Mail ibnsina@omantel.net.om
Phone +972 2 2409616 Fax +972 2 2409790 E-Mail info@intermed-pal.com
Kuwait
Oman
Palestine
Wisam Medical Equipment
Alphamed Co.
Al-Jeel Medical & Trading Co. Ltd.
Abdul Kader Al-Kodsi
Alaa Hamdan Phone +966 1 2168222-236 Fax +966 1 2168566 E-Mail ayasin@aljeel.com www.aljeel.com.sa Saudi Arabia
74
AAMAL MEDICAL CO.
Phone +963 11 2311159 Fax +963 11 2311634 E-Mail wisam-me@scs-net.org Syria
Haitham Mafouz Phone +971 267 30114 Fax +971 267 31224 E-Mail Haitham.T@akigroup.com www.alphamedgroup.com UAE
MedizinTechnik MedizinT echnik
Asia
ATMOS Shanghai Representative Office
Medicorp. Sdn Bhd
Rohit Surgical PVT. LTD.
Rohit Grover
Lily Yan
Priscilla Hue
Phone +91 11 25753575 Fax +91 11 25754575 E-Mail rohitsur@ndf.vsnl.net.in
Brunei
Phone +86 21 64260679 Fax +86 21 64260679 E-Mail SYingYan@atmosmed.de www.atmosmed.com.cn China
MNE TECHNOLOGIES
PT. Surgika Alkesindo
Wako Shoji Co. Ltd.
Phone +673 265 2339 Fax +673 265 2329 E-Mail phue@medicorp.biz
MedizinTechnik
Handy Gunawan
N. Chelvadorai
MedizinTechnik
India
Fumio Osada
Phone +91 80 40545050 Fax +91 80 25590943 E-Mail sales@mneindia.com www.mneindia.com India
Phone +62 21 4253634 Fax +62 21 4253635 E-Mail surgika@cbn.net.id www.surgika.com Indonesia
Phone +81 466 842485 Fax +81 466 842484 E-Mail f.osada@wako-shoji.com www.wako-shoji.com Japan
ATMOS Asia SDN BHD
Europ Continents My.
United BMEC
Christophe Debroise
Matthias Straub Phone +006 03 20727107 Fax +006 03 20728109 E-Mail mstraub@atmosasia.com www.atmosmed.de Malaysia
MedizinTechnik
Phone +95 15 243301 Fax +95 15 05209 E-Mail europcomya@mptmail.net.mm www.europcontinents.com Myanmar/Cambodia/Vietnam/Laos
Vincent Tan Phone +65 63052500 Fax +65 63052549 E-Mail TanVincent@uwhpl.com www.unitedbmec.com Singapore
75
MedizinTechnik MedizinT echnik
Asia
Total Technologies (Pvt) Ltd.
Value-Rx, Inc.
Shoukat Ali Phone +92 42 757-7897 Fax +92 42 753-6586 E-Mail medl@wol.net.pk www.totalgroup.com.pk Pakistan
Endomed (1999) Co. Ltd.
Padon Thuvanalin Phone +66 2731 567-4 Fax +66 2376 0982 E-Mail padon@endomedgroup.com www.endomed.co.th Thailand
76
Mervynsons (PVT) LTD.
Ranil M. Weliwitigoda
Daniel Geiger Phone +63 2 396-5220 Fax +63 2 634-2085 E-Mail danielgeiger@gmail.com
Phone +94 11 2686789 Fax +94 11 2699618 E-Mail mervynsons@asianet.lk
Philippines
Sri Lanka
MedizinTechnik
Australia
Lateral Medical
David Fenech Phone +61 7 31391207 Fax +61 7 30366187 E-Mail david@lateralmedical.com www.lateralmedical.com Australia
77
Medical technology for a better life! ATMOS MedizinTechnik GmbH & Co. has evolved into an exemplary company in the medical technology sector and thus obtained great acceptance. ATMOS stands for: 1. Ongoing growth of ATMOS. We grow at a higher rate than the medical technology market. ATMOS has attained a significant market position in its business units and defined regional markets. We are among the market leaders. 2. ATMOS offers innovative and complete solutions (products and services) which inspire our customers. 3. The success of our company gives us flexibility and the freedom of decision. 4. We are resting solidly on at least 3 „main pillars“ (business units). ENT and Gynaecology workstations digital suction and drainage systems OEM business 5. ATMOS has modern, ideal “business processes”. We have a process oriented organisation. 6. ATMOS has an exemplary „company culture“, the employees enjoy working for ATMOS. Target orientation and transparency of the strategic alignment are important for us. The company and our employees should benefit from our success, this has become reality. 7. The ATMOS trademark is and will remain a strong „brand“ in the field of medical technology, standing for quality and innovation. 8. Competence. Customers, business partners, opinion leaders, salesmen, subsidiaries and agencies enjoy the level of co-operation with ATMOS. They are perfectly trained. 9. ATMOS employees are highly motivated, team-orientated, modern and international thinking, they will go through ‘fire and water’ for their ATMOS. In our region we an esteemed company with good employee opportunities, this also applies to our subsidiaries 10. We are an esteemed enterprise with good employee opportunities, this also applies to all subsidiaries ,Q WKH ¿ HOG RI PHGLFDO WHFKQRORJ\ $7026 LV D JOREDO SOD\HU ZLWK Centres of excellence in Germany and Asia as well as 11 sales companies around the world.
78
ATMOS General terms and conditions MedizinTechnik
1. General:
case. Should the delivery delay be caused by a culpable infringement
also applies in the case of our culpable infringement of substantial
Our General Standard Terms and Conditions apply exclusively. Clientâ&#x20AC;&#x2122;s
of non-substantial contractual duties, our client is also entitled to claim a
contractual duties The indispensable conditions of German Liability Law remain unaffected thereby.
terms and conditions which are contrary to or deviate from our General
one-off damage compen-sation worth 3 percentage points of the delivery
Standard Terms and Conditions are not recognised unless their validity
value of the goods for each weekâ&#x20AC;&#x2122;s delay, up to a maximum which is no
is explicitly confirmed in writing. Our General Standard Terms and
higher than 15 percentage points of the delivery value of the goods
to a period of twelve months.
7. Delivery - Familiarisation
10. Reservation of Ownership
- For second-hand equipment, the period of warranty shall be reduced
Conditions also apply even if we deliver to clients without reservation, in the knowledge of the clientâ&#x20AC;&#x2122;s contrary terms and conditions. Our General Standard Terms and Conditions also apply to all future business with that client. 2. Proposal - Order Confirmation
In the case of the delivery of devices for the medico-technical industry
We retain ownership of our goods until the receipt of all payments
which require assembly and/or familiarisation for the final customer using
arising from the business relationship, including all demands arising
specialist trade personnel (such as Ear, Nose and Throat Apparatus and
from installation orders, subsequent orders, repairs, accessory deliveries
Suction Units), we reserve the right to deliver the goods exclusively to
and replacement orders. Should we have agreed upon payment on the
Our proposals are subject to change without notice unless otherwise
the relevant specialist traders. Should the trader not carry out assembly
basis of cheque and bill transactions, the ownership reservation applies
stated in our order confirmation. Each order is only accepted by us
and/or familiarisation for the final customer, this is carried out by us. In
until the cheque received by us has been paid in, and does not expire
following our written order confirmation. 3. Orders Every order requires an exact description of all of our productâ&#x20AC;&#x2122;s details. We assume no liability for errors and damage caused by inaccurate or
such cases, we reserve the right to charge the client for the additionally
through our credit upon receiving the clientâ&#x20AC;&#x2122;s cheque. In the case of
created costs. Our specialist traders operate a recording system so
a breach of contract by the client, especially payment arrears, we are
that, if necessary, our products can be traced to the final customer. The
entitled to repossess our goods. Repossession of our goods repre-sents
specialist trader undertakes to immediately report to us all events and
a withdrawal from the contract, unless explicitly declared in writing by
risks which must be reported in connection with our products.
us. We have the right to utilise the product after its repossession, whilst
8. Passage of Risk - Packaging
deducting appropriate utilisation costs.The client is responsible for
incomplete ordering details. 4. Prices
the income form such use is balanced against the clientâ&#x20AC;&#x2122;s arrears, after Unless otherwise stated in our order confirmation, delivery is agreed
handling the goods with care. Should maintenance and inspection work
Unless otherwise stated in the order confirmation, our prices in the
ex factory. The risk of the goodsâ&#x20AC;&#x2122; damage or loss is therefore transferred
be necessary, the client must carry these out punctually at his own cost.
order confirmation are ex factory prices and exclude packaging and
to the client as soon as the goods leave the factory or the client is in
Our client is entitled to sell the goods he has bought from us in a proper
value added tax. Packaging is charged separately at cost price in the
default of acceptance of the goods. This also applies to cases where we
sale transaction. However, he must immediately assign all outstanding
invoice. Value added tax is charged separately in the invoice according
confirm prepaid carriage. Transport packaging and all other packaging
claims to the value of the final invoice sum (including value added tax)
to the legal rate on the invoice date. We reserve the right to change
according to the packaging regulations is not returnable. Our client is
of our claims to his customers or third parties. The client is entitled to
prices appropriately should price reductions or increases, especially
responsible for disposing the packaging at its own cost. Our deliveries are
collect this claim even after such assignment. Our right to collect the
due to wage settlements, changes in the price of materials or currency
insured by us at the clientâ&#x20AC;&#x2122;s expense unless explicitly otherwise agreed.
claim ourselves remains unaffected thereby.We undertake to release
fluctuations, be incurred. Proof of such changes will be provided for the
No insurance is arranged in the case of goods which are collected by
the securities to which we are entitled if requested to do so by the
client on request.
our clients. In the case of transport damage, claims are only handled if
client should the realisable value of the our securities be more than 10
the client receives confirmation of any damage, reduced weight or loss
percentage points higher than the outstanding claims. We reserve the
by the shipping company before accepting the delivery.
right to choose the securities to be released.
9. Warranty
11. Plans and Illustrations
5. Payment Conditions - Balancing Unless otherwise stated in the order confirmation, our invoices are payable with a 3% discount within 10 days (except for repair and assembly services) or within 21 days from the invoice date net cash;
The client is responsible for examining the delivered goods
We retain ownership of and copyrights to all plans, illustrations,
money receipts is decisive for complying with this term. We are entitled
immediately after receiving them to determine any eventual deficiencies
calculations and other documents which are attached to our proposals.
to charge interest after the due date at a rate 2% above the relevant
or delivery errors, and to report these immediately. Should the client
The client must receive explicit written permission before passing these
basic interest rate of the German Federal Bank. Should the client have
fulfil this examining and reporting responsibility, and should payment
on to third parties. Imitating our legally patented products is forbidden
payment arrears, we are entitled to charge interest on arrears at a rate
conditions be fulfilled, we shall be liable to the client within the scope
and will be prosecuted.
5% above the relevant basic interest rate of the German Federal Bank.
of legal regulations. Our period of warranty shall in all cases be two
Should we be able to prove higher damages due to arrears, we are also
years. Our client can make use of the warranty as follows, so long as
entitled to claim these. The client only has the right to balance invoices
he can provide first buyer proof (in the form of an invoice or delivery
Our central office is the place of performance for all disputes in
against its own claims should such claims be confirmed in a court of
note) and provided that the product still has the original, unchanged
connection with these General Standard Terms and Conditions and
law or recognised by us. The client does not have the right of retention
serial number:
12. Jurisdiction and Place of Performance
the contracts closed with clients under them. This jurisdiction excludes
due to disputed counterclaims.
a. We choose whether to fulfil our guarantee by providing repair
other jurisdiction relating to persons or subject-matter. Furthermore, our
services free of charge - either on the clientâ&#x20AC;&#x2122;s premises or in our factory
client is not entitled to bring charges against us in another court should
6. Delivery Periods
- or replacing the product. We can also provide these guarantee
Fulfilment of our delivery duties requires the punctual and proper
he file counter-charges, carry out counterbalancing or declare retention.
services through an authorised company;
We, however, are entitled to bring charges against our client at their general place of jurisdiction or at another relevant court recognised by
fulfilment of the clientâ&#x20AC;&#x2122;s duties. The right to defense on the grounds of an
b. Should a product be returned to us, the client agrees to send
unfulfilled contract is reserved.Should the client default in accepting the
the product in its original or similar packaging, offering the same
German or foreign law.Unless otherwise stated in the order confirmation,
goods delivery or breach other cooperation duties, we are entitled either
protection as the original packaging, to our address or any address
our central office is the place of performance.
to withdraw from the contract or claim compensation for any increased
notified by us.
costs incurred up to that time without setting a further deadline. The
c. Our guarantee ceases to apply if changes of any kind have been
right to make further claims is reserved. Furthermore, in such cases,
made to our product, unless such changes have been made by us
Lenzkirch, September 2008
the risk of coin-cidental destruction or a coincidental deterioration in
or a company authorised by us, or have been previously agreed
ATMOS MedizinTechnik GmbH & Co. KG
the quality of the delivered goods is transferred to the client in the case
upon in writing by us. Our guarantee also ceases to apply if third
79853 Lenzkirch/Germany
of default in accepting such goods or payment arrears. Acts of God or
parties have carried out repairs to our products or replaced parts
stoppages (due to insufficient supplies of material, industrial disputes
thereof. This applies regardless of the fact whether these measures
etc.) entitle us either to demand an appropriate extension of delivery
individually or collectively led to a deficiency of the product;
periods or to partly or entirely dissolve the delivery contract. This does
d. We accept no responsibility for damage defects caused by
not give the client the right to claim damages. We have fulfilled delivery
- operational wear and tear;
periods if the delivery goods have left our factory or the client has been
- incorrect installation or incorrect or insufficient maintenance;
informed of the goodsâ&#x20AC;&#x2122; readiness for delivery within such delivery periods.
- incorrect operation of the product (in contradiction to the handbook
Delivery periods stipulated by the client are not recognised by us unless
delivered with the product); - improper use or operating faults; -
they form part of our order confirmation. We adhere to legal terms and
inappropriate or negligent handling and care, especially with respect
conditions in cases where, as a result of an undue delay in the delivery
to dirt, lime, suction of fluids, inappropriate cleaning and sterilisation;
for which we are liable, the client is entitled to claim that his interests
- using accessories and/or replacement parts which are not explicitly
in a continued fulfilment of the contract have ceased. We also adhere
approved;
to legal terms and conditions should a delay in delivery be caused by
- incorrect assembly and/or initial operation by the client or third
deliberate or grossly negligent action by us or our representatives for
parties; - the clientâ&#x20AC;&#x2122;s negligence in handling the product; - unacceptable
which we are responsible. We are also responsible for such actions by
operating conditions, such as humidity, temperatures, the power supply,
our representatives or agents. Should the delivery delay not be caused
vibrations.
by our deliberate infringement of contractual duties for which we are
- accidents, acts of God, especially lightening, water, fire, public
responsible, our liability is limited to damage which is regarded as typical
unrest and insufficient ventilation. We are not liable for damage to
for that case. We are liable according to the legal terms and conditions if
other objects apart from our product itself, except in the case of any
and in so far as the delivery delay for which we are responsible is caused
deliberate or grossly negligent actions by us or our representatives or
by an infringement of a substantial contractual duty. In such cases, our
agents. Should no deliberate breach of contract be claimed, our liability
liability is also limited to damage which is regarded as typical for that
is limited to damage which is regarded as typical for tthat case. This
7KLV FDWDORJXH LV FRS\ULJKWHG 'XSOLFDWLRQ WUDQVODWLRQV PLFURÂżOPLQJ DQG VDYLQJV RQ HOHFWURQLF V\VWHPV SDUWLFXODUO\ IRU FRPPHUFLDOSXUSRVHV are illegal without prior agreement of the manufacturer. All compiled data are based on manufacturers instructions. All logos, product names and designations used in this catalogue are property of the respective manufacturer. :H GR QRW WDNH RYHU DQ\ ZDUUDQW\ DQG OLDELOLW\ LQ WKH FDVH RI PLVVLQJ LQVFULSWLRQV 6XEMHFW WR PRGLÂżFDWLRQV DQG DPHQGPHQWV
MedizinTechnik
www.atmosmed.com Your ATMOS Partner
ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone +49 7653 689-374 Fax +49 7653 68986-374 ApplicationSolutions@atmosmed.de www.atmosmed.com REF
2011-12 Index: 01