ATMOS Surgery catalogue 2012 / 2013 - english

Page 1

MedizinTechnik

octors d d n a ts MOS“ T „Patien A n o rely e d i w d l wor

2012 | 2013 Surgical suction devices & thoracic drainage systems


Table of contents OT-Suction systems

ATMOS Record 55 DDS The powerful allrounder!

ATMOS C 451 / ATMOS C 361 Top performance in the OT at a fair price. The new standard in OT suction!

................................................................................................... page

5 to 9

............................................................................................. page

10 to 18

General Consumables

General surgery Other Accessories and Consumables

ATMOS S 351 Top-class drainage/surgical suction devices. The „thinking“ suction system. ............................................................................................. page

19 to 24

............................................................................................. page

Direct-Docking-System (DDS)

DDS-System Secretion management at the highest stage – Innovative container systems from ATMOS ..............................................................................................................page

Symbols

DVD

Helpful information 2

4

DVD to this topic available

25 to 28


MedizinTechnik

Thoracic drainage

Radiofrequency surgery

ATMOS S 201 Thorax / ATMOS E 201 Thorax The new generation of mobile thoracic drainage systems including therapy success monitoring. ............................................................................................. page

29 to 35

ATMOS RS 221 Cutting and coagulation with maximum precision!

............................................................................................. page

36 to 43

Vacuum and Compressed air

Smoke evacuation

AtmoSafe The most powerful smoke evacuation suction system!

ATMOS ZV 60 / ATMOS ZD 60 Vacuum regulator and suction systems for central vacuum supply and central compressed air supply.

............................................................................................. page

............................................................................................. page

44 to 52

53 to 60

Service worldwide

We offer you complete support so you can care for your patients!

............................................................................................. page

61 to 78

ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone +49 7653 689-374 Fax +49 7653 68986-374 ApplicationSolutions@atmosmed.de www.atmosmed.com 3


ATMOS DDS system MedizinTechnik

Secretion management at the highest level – Innovative canister systems from ATMOS DDS-jar handle, PSU DDS-bacterial filter / oversuction stop, hydrophobic, disposable part DDS-hose adaptor set, Ø 6 + 10 mm DDS-jar lid with gaskets DDS-splash protection DDS-collection jar, polysulphone, 3.0 l

The Direct Docking System for quick, hose-free connection of collection jar and pump

Again and again hose connections are mixed up between suction units and secretion canisters; this results in damaged equipment, expensive repairs and a reduced service life for normal surface filters.

The system features are easy handling during use in the OT. The simple DDS system avoids misuse of the equipment while in theatres. Innovations which facilitate your daily work!

In times of technical innovations this must no longer be accepted. ATMOS offers the perfect solution for these problems.

Secretion management with reprocessable containers: The ATMOS Direct-Docking-System (DDS)

The ATMOS DDS is compatible with the following products:

The hose connections between the suction unit and the secretion canister are omitted and with it easy handling is guaranteed.

ATMOS Record 55 DDS

The DDS filter is a high-performance filter with an internal filter surface (> 1m2 per filter) which is much larger than the surface of a usual surface filter.

ATMOS C 361

The DDS filter prevents the penetration of bacteria into the system and with it the contamination of device and environment. The hydrophobic attributes of the DDS filter prevent the penetration of foam, liquid and aerosol into the pump. Oversuction is almost impossible and expensive repairs are not required.

Foam formation is reduced due to the new design of the inlet. In addition the filter service life is increased.

4

ATMOS C 451 ATMOS ZV 60 ATMOS ZD 60


MedizinTechnik

ATMOS Record 55 DDS Top-class, mobile surgical suction device. Strong, silent and powerful!

The silent top performer!

5


ATMOS Record 55 DDS

ATMOS Record 55 DDS The powerful allrounder!

The ATMOS Record 55 DDS is most suitable for the versatile use in OT due to the high suction performance and the powerful vacuum. The ATMOS Record 55 DDS is the first choice when a silent but powerful suction system is required. Improved technology makes the Record 55 a reliable system for many surgical applications: it is particularly effective for aesthetic plastic surgery and liposuction procedures: Visceral surgery Orthopaedic surgery Thorax surgery Vascular surgery, etc. In particular with regard to aesthetic-plastic surgery especially liposcution - the ATMOS Record 55 DDS is most suitable.

6

The advantages of the ATMOS Record 55 DDS at a glance: Powerful: The airflow rate of 55 litres per minute always provides a free vision in the operating field. Almost noiseless: Low operation noise for concentrated work in the OT. Easy handling Hygienic: Modern canister systems and filters protect staff and patients. Reliable: Approved technology guarantees trouble-free operation. No breakdown caused by blocked bacterial filter


MedizinTechnik

Hose connection with twisted inlet, reduces foam formation and thereforee, longer filter duration.

Quick exchange of bacterial filter which has an extended filter surface.

Changeover lever for comfortable selection of the collection jar during trolley operation.

Foot switch available as an option, anaesthetic proof.

7


| OT suction systems | ATMOS Record 55 DDS - User packages

ATMOS Record 55 DDS

User packages Silent, powerful and user-friendly. The surgical suction device with maximum performance!

Top suction performance Almost noiseless Easy handling

Short start-up time

ATMOS Record 55 DDS - User packages

ATMOS Record 55 DDS (2 x 3 l canister) Mobile surgical suction unit for very high demands, Quiet running, infinitely variable vacuum control, damped vacuum display, change-over for canister selection, for direct docking system canisters, connection for foot controller Technical data: Air-flow rate of pump: 55 ± 3 l/min, vacuum -98 kPa/-735 mmHg at sea level, 230 V~, 50/60 Hz, dimensions (H x W x D): 940 x 500 x 390 mm

REF ❁ 444.0930.0

Included in delivery: basic unit, operating instructions, mains cable, 2 DDS canisters 3 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set Ø 6 mm / Ø 10 mm), suction hose Ø = 6 mm, L = 2.10 m

ATMOS Record 55 DDS (2 x 5 l canister)

Included in delivery: basic unit, operating instructions, mains cable, 2 DDS canisters 5 l, 2 DDS canister lids, 2 DDS canister handle, 2 DDS splash protection, 10 DDS-bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), suction hose Ø = 6 mm, L = 2.10 m

❁ 444.0940.0

Included in delivery: basic unit, operating instructions, mains cable, standard rail (assembled)

❁ 443.0700.0

ATMOS Record 55 with standard rail

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 8


MedizinTechnik

Accessories for all ATMOS Record 55 user packages ➀ Foot switch ➁ Foot regulator set For vacuum control ➂ Deposit tray, stainless steel with support for rail system ➃ Hose support, stainless steel for attaching to standard rail

REF

❁ 443.0755.0 ❁ 443.0770.0 ❁ 443.0790.0

❁ 320.0611.0

You can find further accessories from page 25 on

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 9


ATMOS C 451 / ATMOS C 361 MedizinTechnik

ATMOS C 451 / ATMOS C 361 Top performance in the OT at a fair price.

10

The new standard in OT suction! Elegant and powerful!


ATMOS C 451

ATMOS C 361

The standard in OT suction!

The cost-effective solution!

ATMOS C 451 with 2 x 3 l OT package

ATMOS C 361 with practice package 3 l and trolley

ATMOS C 451

ATMOS C 361

The innovation of the ATMOS C 451 lies in the details: With the innovative DDS (Direct Docking System) it is simpleto disconnect canister, filter and suction hose from the suction unit - and when using the DDS canister system - can bw sterilised and used again. And all this within shortest time! In addition errors in hose connection are completely ruled out. At the same time it is possible to conveniently select the canisters by means of a changeover lever.

For suction procedures with less power requirements the ATMOS C 361 is most suitable: Suction pump with at least 36 l/min, max.-91 kPa Operation without foot switch With trolley Apart from that you can benefit from the same advantage as the ATMOS C 451. Decide for yourself!

11


ATMOS C 451 / ATMOS C 361 MedizinTechnik

Characteristics ATMOS C 451 / ATMOS C 361 – at a glance

ATMOS C 451 with system trolley

ATMOS C 451 table-top device

ATMOS C 361 with trolley

ATMOS C 361 table-top device

Suction pump 45 l

|

|

Suction pump 36 l

|

|

Single-canister system

v

|

v

|

v

v

|

|

| |

|

|

|

Double-canister system ATMOS DDS ( 1,5 l, 3 l) Foot controller / switch Antistatic castors Precision vacuum gauge Carrying handle and container lid Changeover lever Infinitely variable vacuum control

= Standard version

12

| = not available

v = optional available


| OT suction systems | ATMOS C 451 Systems with reusable DDS canisters MedizinTechnik

ATMOS C 451 mobile

Mobile versions

The new benchmark in Design and operability

Secretion management Filter technology

ATMOS C 451 Systems with reusable DDS canisters

ATMOS C 451 with 2 x 3 l canister Powerful surgical suction unit for high demands. Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ball-shaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 45 l/min +/-5 l/min, 230 V~, ± 10%, 50/60 Hz, dimensions: (H x W x D): 330 x 240 x 360 mm, with system trolley 1010 x 360 x 440 mm.

REF ❁ 340.0334.0

Included in delivery: basic unit, mains cable, operating instructions, 2 DDS canisters 3 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, DDS changeover docking station, system trolley, suction hose Ø = 6 mm, L = 2.10 m, standard rail adapter

ATMOS C 451 with 2 x 5 l canister

Included in delivery: basic unit, mains cable, operating instructions, 2 DDS canisters 5 l, 2 DDS canister lids, 2 DDS canister handles, 2 DDS splash protections, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, DDS changeover docking station, system trolley, suction hose Ø = 6 mm, L = 2.10 m, standard rail adapter

❁ 340.0333.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 13


| OT suction systems | ATMOS C 451 Systems with reusable DDS canisters

Systems with reusable canisters DDS

ATMOS C 451 with practice package 1.5 l

Included in delivery: basic unit, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister handle, DDS splash protection, 10 DDS-bacterial filters with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m

❁ 340.0339.0

Included in delivery: basic unit, mains cable, operating instructions, DDS canister 3 l, DDS canister lid, DDS canister handle, DDS splash protection, 10 DDS-bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m

❁ 340.0338.0

ATMOS C 451 with practice package 3 l

ATMOS C 451 mobile with standard rail Designed for continuous operation, silent running, quick mount mechani connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against penetration of liquids, integrated extra large precision vacuum indica loss-free infinitely variable ballshaped vacuum regulator. Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m, standard rail set

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 14

REF

❁ 340.0358.0


MedizinTechnik

Accessories for ATMOS C 451 ➀ DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector ➁ Tray for system trolley ➂ Trolley with standard rail ➃ DDS-standard rail adapter with vacuum connection for the use of disposable systems at the unit Foot switch ➄ Pedal regulator (0...-91 kPa) for infinitely variable vacuum regulation, especially with vacuum extraction, liposuction etc. (can also be retrofitted) DDS-canister set 2 x 3 l consisting of: ▪ 2 DDS secretion canisters 3 l ▪ 2 DDS canister lid sets ▪ 10 DDS-bacterial filters with integrated oversuction stop ▪ 1 suction hose, L = 2 m, Ø 12 mm DDS-canister set 2 x 5 l consisting of: ▪ 2 DDS-collection canister 5 l, polysulphone ▪ 2 DDS-canister lid set ▪ 10 DDS-bacterial filter/oversuction stop ▪ 1 suction hose ➅ DDS-canister lid, complete set consisting of: DDS canister lid, DDS canister handle, DDS splash protection, DDS hose adapter set (Ø 6 mm + Ø 10 mm), DDS bacterial filter oversuction stop, hose holder on DDS canister

REF

❁ 340.0062.0 ❁ 340.0084.0 ❁ 320.0070.1 ❁ 340.0059.0 ❁ 443.0755.0 ❁ 443.0310.1 ❁ 444.0901.0

❁ 444.0902.0

❁ 340.0045.0

You can find further accessories from page 25 on

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 15


| OT suction systems | ATMOS C 451 basic unit

ATMOS C 451 portable

Portable basic unit

The new benchmark in Design and operability

Secretion management Filter technology

ATMOS C 451 basic unit

ATMOS C 451 Powerful surgical suction unit for high requirements. Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ball-shaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 45 l/min +3/-5 l/min, 230 V~, ± 10%, 50/60 Hz, dimensions (H x W x D): 330 x 240 x 360 mm Included in delivery: basic unit, mains cable, operating instructions

ATMOS C 451 portable with standard rail

Technical data

ATMOS C 451 basic unit

Operating time

> 12 h continuous operation without intermittence, within 24 h

Noise level Voltage Weight

Vacuum indicator

Power consumption Capacity of suction

≤ 48 dB (A) @ 1 m (ISO 7779) at max vacuum

230 V~ ± 10%, 50/60 Hz; special voltage: 100 V~ ± 10%, 50/60 Hz; 115 V~ ± 10%, 50/60 Hz; 127 V~ ± 10%, 50/60 Hz approx. 6.7 kg (with secretion container)

-1...0 bar ± 16 mbar (class 1.6) Ø 63 mm max. 173 W

45 l/min +3/5 l/min

The stated technical data are valid at the moment of printing, and are subject to change!

16

REF ❁ 340.0300.0

❁ 340.0357.0


| OT suction systems | ATMOS C 361 Systems with reusable canisters MedizinTechnik

ATMOS C 361

Basic equipment incl. practise package Secretion management - simple, safe and high efficient!

Suction system with at least 36 l /min, - 91 kPa

Can be adapted to trolley with canisters on standard rail system without ATMOS DDS system

ATMOS C 361 Systems with reusable canisters

REF

ATMOS C 361 with practice package 1.5 l Powerful surgical suction unit for high demands. ❁ 340.0351.0 Designed for continuous operation, silent running, quick-mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra-large precision-vacuum indication, loss-free, infinitely variable ballshaped vacuum regulator. DDS system for hose-free coupling of the pump to the DDS canister. Technical data: Vacuum 0 up to -91 kPa/-682 mmHg, pump performance: 36 l/min ± 4 l/min, 230 V~ ± 10%, 50/60 Hz, Dimensions (H x W x D): 330 x 240 x 360 mm Included in delivery: basic unit, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister handle, DDS splash protection, DDS bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m

ATMOS C 361 with practice package 3 l

Included in delivery: basic unit, mains cable, operating instructions, DDS canister 3 l, DDS canister lid, DDS canister handle, DDS splash protection, DDS bacterial filter with integrated oversuction stop, DDS hose adapter set (Ø 6 mm / Ø 10 mm), DDS hose holder on canister, suction hose Ø = 6 mm, L = 2.10 m

❁ 340.0350.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 17


| OT suction systems | ATMOS C 361 Systems with reusable canisters

ATMOS C 361 mobile with standard rail Designed for continuous operation, silent running, quick mount mechanism forconnection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, lossfree infinitely variable ball-shaped vacuum regulator, DDS port for the hose-free connection of the pump to the DDS canister.

REF

❁ 340.0360.0

Included in delivery: Basic device, system trolley, mains cable, operating instructions, DDS canister 1.5 l, DDS canister lid, DDS canister carrying handle, DDS splash protection, 10 DDS bacterial filter with integrated overflow protection, DDS hose adapter set, DDS hose holder, suction hose l = 2.1 m

ATMOS C 361 mobile with 3.0 l practice package Designed for continuous operation, silent running, quick mount mechanism forconnection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, lossfree infinitely variable ball-shaped vacuum regulator, DDS port for the hose-free connection of the pump to the DDS canister.

❁ 340.0361.0

Included in delivery: Basic device, system trolley, mains cable, operating instructions, DDS canister 3.0 l, DDS canister lid, DDS canister carrying handle, DDS splash protection, 10 DDS bacterial filter with integrated overflow protection, DDS hose adapter set, DDS hose holder, suction hose l = 2.1 m

ATMOS C 361 mobile with standard rail Designed for continuous operation, silent running, quick mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, loss-free infinitely variable ball-shaped vacuum regulator.

❁ 340.0362.0

Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m

ATMOS C 361 portable with standard rail Designed for continuous operation, silent running, quick mount mechanism for connection to system trolley without the use of tools, two vacuum attachments, easy to clean surfaces with additional protection against the penetration of liquids, integrated extra large precision vacuum indication, loss-free infinitely variable ball-shaped vacuum regulator.

❁ 340.0363.0

Included in delivery: Basic device, system trolley, mains cable, suction hose l = 2.1 m, adapter for standard rail system

Accessories for ATMOS C 361 Trolley with standard rail DDS-standard rail adapter with vacuum connection for the use of disposable systems at the unit

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 18

❁ 320.0070.1 ❁ 340.0059.0


MedizinTechnik

ATMOS S 351 Top-class drainage/surgical suction device. The“thinking“ suction system!

The universal suction specialist for: Neurosurgery Cardiac Surgery Gastroenterology Urology General Surgery

19


ATMOS S 351

ATMOS S 351

g

f

h

What are your basic requirements with regard to a suction system in the operating theatre? Considerable demands are made with regard to the reliability of medical technology especially in critical operating situations. During your daily work you are exposed to a noise level, which should not be underestimated – you do not need a rise in noise level due to the suction device employed in this connection! In support of this ATMOS has a suction unit in that range which meets the following requirements: Absolutely stable vacuum due to processor controlled regulation automatism

20

100% precise vacuum setting due to sensor technology Tissue protection function: prevents damage to sensitive tissue caused by adherent cannulas. Whenever a pre-set maximum vacuum limit is reached, a valve opens and the suction system „lets go“. Automatic Standby Function: The system starts up automatically when secretion has to be extracted and stops when the secretion has been completely removed. In brief: small mobile, quiet, safe and secure!


MedizinTechnik

The processor-controlled c automatic control system Simple and rapid vacuum preselection at the touch of a button, no loss of air, unlike mechanical vacuum controllers

d Intermittent suction for drainage applications

Specially designed safety f jar ensures no damage is caused by oversucking Safety jar without filter REF 444.0646.0 Safety jar with filter REF 444.0646.1

g Hydrophobic bacterial filter with filter replacement indicator REF 443.0738.0

display e High-resolution showing desired/actual vacuum choice of mbar, mmHg oder kpa

Double socket nipple for h rapid jar replacement REF 444.0012.0

21


| OT suction systems | ATMOS S 351

ATMOS S 351 OT

Basic equipment The „thinking“ suction system for OT and ward!

Advantages in OT: Protects delicate tissue from suction adherence Vacuum preselection at the touch of a button Almost noiseless

ATMOS S 351

REF

ATMOS S 351 OT basic unit 1.5 l canister (PSU) Microprocessor-controlled suction unit ❁ 444.0461.0 with graphic-LCD-display, automatic vacuum control, standby automatic, filling level control with automatic switching off, suction adherence detection and intermittence for protecting delicate tissue and for gastroscopic and wound drainage, safety canister 250 ml for condensed water, bacterial filter with hydrophobic attribute. Technical data: pump performance: 36 l/min ± 2 l/min, Vacuum 90 kPa/-675 mmHg, 230 V~ ± 10%, 50/60 Hz, Dimensions: (H x W x D): 300 x 330 x 200 mm Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, set with 1.5 l canister (PSU) incl. lid and double socket nipple, hydrophobic bacterial filter, hose holder, hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.3 m

ATMOS S 351 OT set with 2 x 3 l canister (PSU)

Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, set with 2 x 3 l canister (PSU) incl. lid and double socket nipple, hydrophobic bacterial filter, hose holder, hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.3 m

❁ 444.0471.0

ATMOS S 351 - basic unit Microprocessor-controlled suction unit ❁ 444.0460.0 with graphic-LCD-display, automatic vacuum control, standby automatic, filling level control with automatic switching off, suction adherence detection and intermittence for protecting delicate tissue and for gastroscopic and wound drainage, small secretion canister 250 ml incl. bacterial filter with hydrophobic attribute. Technical data: pump performance: 36 l/min ± 2 l/min, Vacuum 90 kPa/-675 mmHg, 230 V~ ± 10%, 50/60 Hz, dimensions (H x W x D): 300 x 330 x 200 mm Included in delivery: basic unit, mains cable, operating instructions, safety canister 250 ml, hydrophobical bacterial filter, hose holder hose Ø 10 mm, L = 2 m, hose Ø 6 mm, L = 1.30 m

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 22


MedizinTechnik

Accessories for completing the ATMOS S 351 ➀ Secretion canister lid incl. standard rail holder with overflow electrode and splash protection ➁ Double socket nipple consisting of double socket nipple and hose reduction Graduated secretion canister 1.5 l Height 192 mm, external Ø 115 mm Secretion canister 1.5 l PSU, sterilisable up to 134 °C ➂ Graduated secretion canister 3 l Height 247 mm, Ø 145 mm Secretion canister 3 l PSU, sterilisable up to 136 °C Graduated secretion canister 5 l Height 302 mm, Ø 169 mm Secretion canister 5 l PSU, sterilisable up to 136 °C Standard rail support For disposable system Medi-Vac® 1 l, 1.5 l. Safety canister 250 ml, for condensed water Safety canister 250 ml with integrated DDS-bacterial filter / overflow stop, incl. adapter for arthroscopy (Shaver, Lavagen), oral and maxillofacial surgery, liposuction etc. Hose holder, for attaching to standard rail (plastic, white) Basket for catheters, L = 340 mm Instrument quiver for attachment to standard rail, Ø 60 mm, height 170 mm Catheter quiver for catheter storage, with support for rail system, height 410 mm, Ø 105 mm, for standard rail 10 x 30 mm. Quiver holder incl. standard rail support, height 190 mm, Ø 55 mm, for standard rail 10 x 30 mm.

Technical data

ATMOS S 351 basic unit

Voltage

230 V~ 50/60 Hz; special voltage: 115 V~ 50/60 Hz

Noise level

Dimensions (H x W x D) Weight

Classifications Capacity of suction

REF

❁ 444.0015.0 ❁ 444.0012.0 ❁ 444.0032.0 ❁ 444.0036.0 ❁ 444.0033.0 ❁ 444.0037.0 ❁ 444.0034.0 ❁ 444.0038.0 ❁ 444.0451.0 ❁ 444.0646.0 ❁ 444.0646.1 ❁ 444.0450.0 ❁ 444.0140.0 ❁ 340.0065.0 ❁ 443.0780.0 ❁ 444.0145.0

46 dB (A) @ 1m (acc. to ISO 7779)

300 x 330 x 200 mm, without trolley; 840 x 490 x 520 mm, with trolley

10.2 kg, without secretion jar, without trolley; / with trolley: 24.7 kg

protection category: IPX0; protection class: I; degree of protection: type B, class: IIb (acc. to appendix IX dirctive 93/42 EEC) 44 ± 2 l/min

The stated technical data are valid at the moment of printing, and are subject to change!

23


| OT suction systems | Accessories for completing ATMOS S 351

Accessories for completing ATMOS S 351 ➀ Trolley on 4 castors, self-assembly Attention: Trolley and small suction units cannot be screwed up in standard version! If required, we will deliver a special design of the suction unit. Trolley with antistatic castors ➁ Foot controller electrical, water-proof IPX 8, AP-protected

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 24

REF

❁ 320.0070.0 ❁ 444.0020.0 ❁ 444.0452.0


MedizinTechnik

Miscellaneous accessories and consumables For ATMOS Record 55, ATMOS C 451 und ATMOS C 36

25


| Accessories and consumables for general surgery

Accessories for DDS DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector DDS-secretion canister, plastic, 1.5 l, autoclavable Height 146 mm, external Ø 166 mm DDS-secretion canister, plastic, 3 l, autoclavable Height 247 mm, external Ø 166 mm DDS-secretion canister, plastic, 5 l,autoclavable Height 396 mm, external Ø 166 mm DDS-canister lid, complete set consisting of: DDS canister lid, DDS canister handle, DDS splash protection, DDS hose adapter set, Ø 6 mm + Ø 10 mm, DDS bacterial filter / oversuction stop, hose holder on DDS canister. DDS-canister lid with gaskets DDS-canister handle, grey Canister handle, blue DDS-splash protection, silicone DDS-hose adapter set, Ø 6 mm + Ø 10 mm DDS-hose holder Single-Docking-Station (SDS) Single-docking-station enables the use of DDS-canisters in connection with ZV / ZD systems. Attention: please order canister with lid separately! Consummables DDS Bacterial filter for DDS secretion canister, 10 pcs. disposable, not autoclavable, Change: daily, with same patient: ca. every 14 days DDS adapter for tissue collector connects the ATMOS DDS canister to the tissue collector

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 26

REF

❁ 340.0062.0 ❁ 340.0050.0 ❁ 340.0051.0 ❁ 340.0052.0 ❁ 340.0040.0

❁ 340.0053.0 ❁ 340.0055.0 ❁ 340.0326.0 ❁ 340.0056.0 ❁ 340.0057.0 ❁ 340.0066.0 ❁ 320.0640.0

❁ 340.0054.0 ❁ 340.0062.0


MedizinTechnik

Accessories Receptal Receptal®-canister set 2 x 1.5 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 1.5 l, 2 Receptal®-suction bag 1.5 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal®-canister 1,5 l Receptal®-canister set 2 x 2 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 2 l, 2 Receptal®-suction bag 2 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal® canister 2 l Receptal®-canister set 2 x 3 l consisting of: Receptal®-holder complete, 2 canisters for Receptal®-suction bags 3 l, 2 Receptal®-suction bag 3 l, one of them with integrated overflow valve filter, connection hose L = 12 cm Basic unit must be ordered separately! Receptal® canister 3 l

REF

❁ 444.0022.0

❁ 310.0221.0 ❁ 444.0023.0

❁ 443.0256.0 ❁ 444.0024.0

❁ 444.0157.0

Included in the delivery of Receptal® packages are the same items as included in the Receptal®-canister sets, apart from the Receptal® holder complete which is replaced by 2 Receptal® holders for one canister.

Receptal® package 2 x 1.5 l

❁ 444.0027.0

Receptal® package 2 x 2 l

❁ 444.0028.0

Receptal® package 1 x 2 l Receptal® package 1 x 3 l Receptal® package 2 x 3 l

Consummables Receptal Receptal® suction bag 1.5 l, not autoclavable, 50 pcs. Receptal® disposable bag 2 l, without integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient Receptal® suction bag 2 l, with integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient Receptal® suction bag 3 l, without integrated overflow protection For tandem hose system, not autoclavable, 50 pcs., change: 1 x per patient. Receptal® suction bag 3 l, with integrated overflow protection Not autoclavable, 50 pcs., change: 1 x per patient.

❁ 444.0030.0 ❁ 444.0031.0 ❁ 444.0029.0 ❁ 310.0222.2 ❁ 443.0257.0 ❁ 443.0257.2 ❁ 444.0153.0 ❁ 444.0154.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 27


| Accessories and consumables for general surgery | Further accessories for general surgery

Further accessories for general surgery ➀ Serres® external canister 1 l Serres® suction bag, 1 l, not autoclavable, 36 pcs. with angled connection Serres® canister 2 l Serres® suction bag 2 l with gelling agent not autoclavable, 22 pcs. Serres® canister 3 l Serres® suction bag 3 l with gelling agent not autoclavable, 20 pcs. Serres® dev. holder Accessories MediVac® Medi-Vac® canister 1 l Standard rail support For disposable system Medi-Vac® 1 l, 1.5 l.

Consummables MediVac® Medi-Vac® suction bag 1 l, not autoclavable, 50 pcs.

General consummables ➁ Suction hose, silicone, Ø 6 mm, L = 2 m, 1 pc Autoclavable at 134 °C, change: after 20 x autoclaving ➂ Suction hose, silicone, Ø 10 mm, L= 2m, 1 pc Autoclavable at 134 °C, change: after 20 x autoclaving Suction hose, disposable, Ø 6 mm, L = 2.10 m, 50 pcs. Change: 1 x per patient Bacterial filter disposable, not autoclavable, change: 1 x per patient Bacterial filter FFG - hydrophobic Bacterial filter disposable, not autoclavable, Change: 1 x per patient ➃ Tissue collector 300 ml, disposable Ø 6 mm, change: 1 x per patient ➄ Collector sieve, disposable 50 ml, change: 1 x per patient Secretion canister lid incl. standard rail holder Socket nipple set consisting of: Double socket nipple, hose reducer, mechanical overflow safety Deposit tray, stainless steel with support for rail system

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 28

REF

❁ 312.0465.0 ❁ 312.0466.0 ❁ 310.0402.0 ❁ 310.0400.0 ❁ 310.0403.0 ❁ 310.0401.0 ❁ 340.0095.0 ❁ 312.0473.0 ❁ 444.0451.0 ❁ 312.0474.0 ❁ 000.0361.0 ❁ 000.0243.0 ❁ 006.0059.0 ❁ 443.0738.0 ❁ 444.0082.0 ❁ 444.0628.0 ❁ 340.0061.0 ❁ 401.0555.0 ❁ 444.0650.0 ❁ 444.0640.0 ❁ 443.0790.0


MedizinTechnik

ATMOS S 201 Thorax / ATMOS E 201 Thorax

The Bülau-drainage with a „brain“

The new generation of mobile thoracic drainage systems including therapy success monitoring 29


ATMOS S / E 201 Thorax

The intelligent thoracic drainage system

ATMOS E 201 Thorax ATMOS S 201 Thorax

Whereas technical developments have progressed at breakneck speed in virtually all other areas of OTs or intensive care and critical care units, thorax drainage procedures are frequently the same as they were 100 years ago - with all the disadvantages that this entails from a modern perspective. Problems: patients experience unnecessarily long periods of immobilisation intensive nursing care risk during transportation within the clinic materials used incur high costs no alarm function in the event of an error etc. The solution: the 2nd ATMOS generation of mobile thorax drainage systems

30


MedizinTechnik

The compact lightweight as a complete solution subsequent therapy success monitoring without unnecessary x-ray complete documentation of vacuum DQG ÀRZ IURP WKH 27 XS WR WKH removal of the drain improved patient safety and therapy success UHGXFHG QXUVLQJ FDUH FRVWV E\ WKH increased capacity of the secretion canister. No constant exchanges of the hoses and canisters the risk of follow-up costs is minimised through rapid mobilisation of the patient improved safety due to easily detec table alarm signaling and connection to the nurse call system eases the burden on the nursing staff

The innovations: More powerful than ever Now with 20 l/min! The new ATMOS thoracic drainage systems ATMOS E 201 Thorax and ATMOS S 201 Thorax with 20 l/min, making them the most powerful electrical drainage systems in the world. 5HDO WLPH ÀRZ PHDVXUHment system 7KH XQLTXH $7026 ÀRZ measurement system enables (real-time) display of WKH DFWXDO ÀRZ FRXQW LQ O PLQ to the second. The nursing staff and doctors are consequently kept LQIRUPHG DERXW WKH ¿VWXOD VWDtus of the patient at all times. Digital therapy control ATMOS S 201 Thorax saves WKH UHDO WLPH ÀRZ PHDVXrement data and shows a progress curve on the colour display. The entire recovery process is thus displayed.

Documentation of the course of treatment The saved data can be read in MS Excel format from an integrated micro SD card and DOORFDWHG WR WKH SDWLHQW ¿OH The course of treatment is thus accessible at all times. Direct vacuum measurement and patient monitoring By means of the ATMOS measuring hose system the set vacuum parameters are measured close to the patient. The „siphon effect“ is excluded because the set parameters are constantly monitored and changes in the status are automatically balanced.. Safe Alarm signalisation The alarm function is designed to make the alarm easily detectable or audible in a noisy environment. The ATMOS S 201 Thorax model may be connected to a nurse call system.

Thorax drainage system

Max. 20 l/min

ATMOS E 201 Thorax

ATMOS S 201 Thorax

z

z

ATMOS disposable container system

z

z

Battery operation

z

z

5HDO WLPH ÀRZ PHDVXUHPHQW

z

z

Flow history

z

Data export via SD card

z

Monitoring function

z

z

Connection to SRS

z

Graphic display

z

z

Colour display

z

z available

|

not available 31


ATMOS S / E 201 Thorax

ATMOS S / E 201 Thorax Mobility is the key

Easy and safe operation

Secretion canister

Connection for secretion hose

Sealing caps for sealing the pop off valve and the secretion hose connection

2 litre secretion chamber with spill over function

Container system for ATMOS E 201 Thorax and ATMOS S 201 Thorax The secretion container different from others - offers maximum safety and mobility for the patient.

32

The very sturdy container has - apart from the spacious secretion chamber with a capacity of 2 litres - an integrated water lock.

The enclosed sealing caps enable safe and hygienic disposal.


MedizinTechnik

Display (graphic mode)

Pop off valve

SD card status

Âż OOHU IRU ZDWHU ORFN

Patient number Current measured vacuum parameter at the patient

Battery charging status

Hydrophobic EDFWHULDO ¿ OWHU ZLWK UHOLDEOH RYHUÀ À RZ protection Vacuum scale

Water lock

Flow value scale H[WHQW RI Âż VWXOD

Time line IURP WKH Âż UVW PLQXWH up to 12 days)

Display ATMOS S 201 Thorax (Graphic mode) Real-time Flow Measuring System:

Digital therapy monitoring:

Documentation:

Direct vacuum measurement

Makes it possible to measure WKH FXUUHQW À RZ SDUDPHWHUV LQ l/min with to-the-second precision (real-time). This means that care personnel and physicians are informed DERXW WKH SDWLHQWœV ¿ VWXOD status at all times.

Data storage from the UHDOWLPH À RZ PHDVXUHPHQW readout on the colour display as progression curve. Therefore the progression of healing can be shown without JDSV IRU WKH ¿ UVW WLPH

Via an integrated SD card, the stored data can be output in Excel format and assigned WR WKH SDWLHQW Âż OH 7KLV PDNHV it possible to trace the progression of treatment at all times.

Through the ATMOS measuring tube system, the vacuum parameter is measured directly at the patient. The risky siphon effect is excluded. Well-thought-out alarm functions and the connection to a nurse call system (ATMOS S 201 Thorax) facilitate daily work in clinics.

33


| Thorax drainage | ATMOS E 201 Thorax / ATMOS S 201 Thorax

ATMOS S 201 Thorax / ATMOS E 201 Thorax

Digital thoracic drainage now with 20 l/min suction performance real-time flow measuring system

digital control of the therapy monitoring

direct vacuum measurement at the patient secure alarm signalling 2 l capacity

Integrated water lock with bacterial filter and oversuction protection

ATMOS E 201 Thorax / ATMOS S 201 Thorax

ATMOS E 201 Thorax Mobile thoracic drainage system of the ATMOS "E-class". Suitable for transport within the hospital and to accompany the patient from the operating room to the end of therapy, Fully electronic monitoring, real-time flow measurement, alarm function, ergonomic monochrome display. Technical data: Pump performance: 20 l/min ± 4 l/min, noise level: max 39 dB (A) 1m (acc. to ISO 7779) dimensions (H x W x D): 366 x 250 x 168 mm

REF ❁ 312.1100.0

Included in delivery: basic unit, micro SD card, carrying strap, mains cable, operating instructions, hose clamp

ATMOS S 201 Thorax Mobile thoracic drainage system of the "S-class". Suitable for transport within the hospital, and to accompany the patient from the operating room to the end of therapy. Fully electronic monitoring, realtime flow measurement, flow history, data export via SD card, alarm function (can be connected to a nurse call system), ergonomic colour display. Technical data: Pump performance: 20 l/min ± 4 l/min, noise level: max 39 dB (A) 1m (acc. to ISO 7779) dimensions (H x W x D): 366 x 250 x 168 mm Included in delivery: basic unit, micro SD card, carrying strap, mains cable, operating instructions, hose clamp

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 34

❁ 312.1000.0


MedizinTechnik

Accessories ➀ Universal bracket Bracket for fastening the ATMOS S 201 Thorax / ATMOS E 201 Thorax on the patient bed, standard rail, wheelchair, tripod, etc Carrying bag for canister Carrying bag for the transport of the canister when using it as gravity drainage. With carrying strap, infinitely variable, 2.5 cm wide. Micro SD card Consumables ➁ OT-Set for ATMOS E/S 201 Thorax consisting of: 10 canisters, 10 hoses (steril) Hose system for ATMOS E/S 201 Thorax, 180 mm length, sterile, for connection to secretion container, REF 312.1150.0 2 l secretion jar, sterile, 10 pcs.

REF

❁ 312.1160.0 ❁ 312.1005.0 ❁ 312.2021.0 ❁ 312.1031.0 ❁ 312.1170.0 ❁ 312.1150.0

Technical data

Operation modes Noise level Voltage

Dimensions (H x W x D) Weight

Classifications Capacity of suction

ATMOS S 201 Thorax

ATMOS E 201 Thorax

Continuous operation with network supply, min. 60 min. at 15 l/min of continuous suction max. 39 dB (A) (acc. to ISO 7779) 100 ... 240 V~ 50/60 Hz 366 x 250 x 168 mm

3.6 kg including empty container

protection type: IPX0; protection class: II; Class: IIa (in accordance with Appendix IX of the Directive 93/42/EEC)

The stated technical data are valid at the moment of printing, and are subject to change!

16 l/min ± 4 l/min

35


Radiofrequency surgery | Application information MedizinTechnik

The problem of previous surgical methods

Radiosurgical interventions with the ATMOS RS 221 Lid plasty Rhinoplasty Epilation Facelift Otoplasty

Excision, Superficial ablation

Mammaplasty

Dermatoplasty

Abdominal plasty

ATMOS RS 221 The Innovation!

36

Aesthetic and plastic surgeons wish – with regard to the patient – to operate with the best methods. Incisions with a scalpel are usually performed with traction and pressure, in doing so the tissue can slip especially in the case of soft or thin skin areas – a perfect aesthetic result is almost impossible. Incisions with laser may damage the surrounding tissue due to the extreme impact of heat – a longer and painful wound healing may be the result.

Is there a better method which is even more favourably-priced? The radiofrequency surgery offers new possibilities and has none of the aforesaid weaknesses. The advantages are the perfect results and the simplicity of the method. More and more plastic surgeons can no longer imagine a surgical intervention without radiowaves – for experienced doctors with radiosurgical systems the advantages compared to the other methods like scalpel, laser or HF surgery are indisputable. Less impact of heat on the tissue speeds up the healing process and has a positive influence on the post-operative well-being. The incisions are smooth without the tissue being squeezed. The incision with the selfsterilizing radiofrequency electrode improves the haemostasis and results in an almost scarless wound healing.


Radiofrequency surgery – The revolution is called “cold” incision

A new dimension of precision Thanks to an innovative technology the ATMOS RS 221 enables incisions without pressure and traction which result in smooth incisions which heal quickly and are considerably less painful. Minimized scarring is the result of less cell damage. Why radiofrequency surgery? There is no damage of the surrounding tissue due to less lateral heating during radiofrequency surgery. This is an essential advantage compared to kHz devices: less tissue necrosis and minimized scarring – thanks to the unexcelled precision even the first incision through the cuticle is now possible with a MHz device! With the new method the histological examination of excised tissue is now possible up to the tissue edge. The ATMOS RS 221 is operated with a frequency of 2.2 MHz because over 3 MHz there could be safety critical antenna effects, and still the medical result is not improved. Radiofrequency surgery versus laser Apart from the fact that the price for laser equipment is ten times more expensive than for the ATMOS RS 221 the applied laser beam develops tissue damaging heat which may cause damage to the surrounding tissue – burnt skin around the wound edges and increased scarring may be the result. Thanks to radiofrequency even skin burning in the case of wetness at the neutral electrode is no longer possible – an important advantage in pediatric surgery. Another important advantage for the OT staff is the reduced laser smoke and herewith the reduced infection risk!

In combination with the ATMOS smoke evacuation system AtmoSafe this adverse effect could be eliminated completely. The multifunctional device for many areas of application Thanks to its invaluable advantages the ATMOS RS 221 radiofrequency surgery device is used mostly for plastic surgery e.g. eyelid lift: with current surgical methods, using a scalpel, laser or electrosurgery, the surgical result in the case of fine skin is insufficient. But even other interventions like rhinophyma or the endoscopic eyebrows lift, hair transplantation, removal of tumours etc. benefit from the use of the ATMOS RS 221. Extensive surgical interventions e.g. mammaplasty, dermatoplasty and abdominal plasty can also be easily performed. 3 operation modes, 3 outlets With the ATMOS RS 221 the surgeon has three different operation modes at his disposal: Cutting (Mono Cut) Cutting and monopolar coagulation (Mono Coag) Coagulation and bipolar coagulation (Bipol Coag) Thanks to the comprehensible symbols the operation of the device is easy – the colour-coded electrodes enable an easy selection of the respective outlet. Without any changeover the surgeon may decide to operate with either tool holder or foot switch Please request therefore alsoour information-DVD: Phone: +49 7653 689-374 ApplicationSolutions@atmosmed.com

37


ATMOS RS 221

ATMOS RS 221

Cutting and coagulation with maximum precision! With the radiofrequency surgical device ATMOS RS 221 ATMOS has added a top-class electrosurgical device to the product portfolio in the business range surgery. During an incision with a scalpel the skin is tightened, the incision itself requires pressure. The result: Imprecise transections, especially in the case of skin unevenness. In case incisions are carried out with conventional HF surgical devices or with laser instead of a scalpel quiet often the result is carbonized wound edges with a delayed wound healing and increased scarring. With the ATMOS RS 221 these disadvantages are eliminated. The incision – even the first incision through the epidermis – is now possible with extremely high precision

38

without traction and pressure. There is no thermal damage to the surrounding tissue and therefore, the wound healing and the scarring are minimized. The consequence is a perfect aesthetic result. With the use of the frequency range of 2.2 MHz tissue is only vaporised where the cutting electrode is in contact with the tissue. The resistance of the tissue prevents the propagation of radiowaves and therefore also a corbonation of the lateral tissue. ATMOS offers a wide range of accessories for the ATMOS RS 221 e.g., electrodes for the incision, coagulation and ablation. For particular safety in the OT the combination of the ATMOS RS 221 and the smoke evacuation system AtmoSafe is perfect.


MedizinTechnik

MONO CUT Always the perfect incision performance for every type of tissue

Symbol buttons Left: Symbol for operating mode Right: Symbol for device type acc. to EN 60 601-1 Below: Symbol for neutral electrode (illuminates in case of malfuction)

MONO COAG For the smooth coagulation with definable depth effect Set of electrodes

BIPOL COAG Safe bipolar coagulation

D

DV

39


| HF- and Radiosurgery | ATMOS RS 221

ATMOS RS 221

Basic equipment

Disciplines: Aesthetic plastic surgery

General and reconstructive surgery Dermatology OMS ENT

Gynaecology

Precision

Aesthetic result

ATMOS quality and service Price-performance ATMOS RS 221

ATMOS RS 221 radiosurgery system 2.2 MHz 4 operating modes: cutting, coagulation-cutting, monopolar-coagulation, bipolar-coagulation, automatic switch of outputs: cutting/coagulation alternatively via handpieces or foot switch. Memory function for storing the last used values. Technical data: Cutting performance max. 100 W, coagulation performance max. 90 W, Standard ATMOS-, Martin-, Berchtoldconnections Included in delivery: basic unit, mains cable, maintenance book, operating instructions

Technical data

ATMOS RS 221

Dimensions (H x W x D)

138 mm x 285 mm x 230 mm

Voltage Weight

Classifications Rated frequency Fuses

Output voltage

Working frequency

Max. coagulation performance: Cutting performance Colour

230 V~

4 kg, accessories plus 1.8 kg

protection class: I; degree of protection: type BF; defibrillationproof; class IIb (acc. to appendix IX, directive 93/42/EEC) 50 / 60 Hz

2 x T 1,6 A / H at 230 V~, 2 x T 3,15 A / H at 115 V 500 V max. top level output voltage 2.2 MHz

max. 90 Watt at 1 kOhm max. 100 W at 1 kOhm

grey-white (RAL 9002) / dove-blue (RAL 5014)

The stated technical data are valid at the moment of printing, and are subject to change!

40

REF â? 506.5800.0


MedizinTechnik

Accessories for ATMOS RS 221

ATMOS RS 221 monopolar accessories set autoclavable at 134 °C consisting of: handle, yellow, cutting (for 1.6 mm electrodes), handle, blue, coagulating (for 1.6 mm electrodes), standard set of electrodes (41, 43, 44, 45, 46, 47, 48), neutral electrode with rubber fixation, connection cable for neutral electrode.

ATMOS RS 221 bipolar accessories set ➀ autoclavable at 134 °C consisting of: bipolar tweezers, short, straight, L = 110 mm, width of the tip 0.5 mm, foot switch with 2.5 m cable, bipolar cable, L = 2.5 m. ➁ Handle for cutting, yellow for 1.6 mm electrodes, cable length 2.5 m, autoclavable ➂ Handle for coagulation, blue for 1.6 mm electrodes, cable length 2.5 m, autoclavable Neutral electrode , 168 x 112 mm (185 cm²) cable length 0.5 m, autoclavable up to 134 °C (at least 75 x) Connecting cable for neutral electrode Rubber bandage for neutral electrode, L = 0.5 m Foot switch for grip without a release button, cable L = 2.5 m Bipolar cable, L = 2.5 m, autoclavable (at least 300 x) ➃ Bipolar tweezers, short, straight, L = 110 mm With of the tip 0.5 mm

REF ❁ 506.5850.0

❁ 506.5860.0

❁ 506.5851.0 ❁ 506.5852.0 ❁ 506.5853.0 ❁ 506.5854.0 ❁ 506.5855.0 ❁ 506.5861.0 ❁ 506.5862.0 ❁ 506.5863.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 41


| HF- and Radiosurgery | Accessories for ATMOS RS 221

d

e f

g h

c

i

j

Consumables for ATMOS RS 221 ➀ Self-adhesive disposable electrodes Size 104 x 215 mm (for adults) Included in delivery: 50 pcs.

➁ Cable for self-adhesive disposable electrode, length 3 m With plug for the ATMOS RS 221 and clamp connection with twin bolt to the single-use neutral electrode, autoclavable

❁ 506.5877.0

➂ Special electrode for Uvulopalatoplasty Teflon coated, for safe and gentle removal of the uvula and the soft palate. To be used for chronic snorers. Overall length: 100 mm

❁ 506.5886.0

➃ Cutting ENT needle electrode (extra long), #32 Flexible shaft, L = 100 mm, fine wire

❁ 506.5881.0

➄ Coagulation ENT ball-shaped electrode (extra long), #34 Flexible shaft, L = 100 mm, Ø ball 2,3 mm

❁ 506.5883.0

➅ Cutting ENT loop electrode (extra long), #35 Flexible shaft L = 128 mm, Ø loop 9 mm, super-fine wire

❁ 506.5882.0

➆ Coagulation-electrodes, pointed needle electrode, #36 Coated and bent electrode for coagulation of the lingual tonsils and the submucous UPP; also very suitable for the preparation of fat tissue. L = 105 mm, length of needle = 18 mm (12 mm isolated)

❁ 506.5884.0

➇ Multi-tip electrode, with spare wire, #41 with adjustable wire, for depth control (2 pcs.), wire 0.2 mm

❁ 506.5870.0

Included in delivery: 1 pc.

Included in delivery: 2 pcs.

Included in delivery: 2 pcs.

Included in delivery: 2 pcs.

Included in delivery: 1 pc.

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 42

REF

❁ 506.5878.0


MedizinTechnik

c

d e f g

h

i

j

k

➀ Cutting-electrode, round loop, Ø 13 mm, #43

❁ 506.5871.0

➁ Cutting-electrode, round loop, Ø 7 mm, #44

❁ 506.5872.0

➂ Cutting-electrode, rhombical, #45 leg length 7 mm

❁ 506.5873.0

➃ Cutting-electrode, triangle electrode, # 46 leg length 7 mm

❁ 506.5874.0

➄ Coagulation-electrode, thick needle-electrode, #47 needle Ø = 1.5 mm, needle length 1.5 mm

❁ 506.5875.0

➅ Coagulation-electrode, ball-shaped-electrode, Ø ball 2 mm, # 48

❁ 506.5876.0

➆ Electrode for the nasal radioconchotherapy, #52 Bayonet-shaped, total length = 155 mm, length of needle = 26 mm (10 mm isolated), blue shaft

❁ 506.5885.0

➇ Bipolar needle electrode (puncture electrode), # 03 For volume reduction of the nasal concha. Bent on the rear, isolated needles, ergonomic plastic handle. Total length: 188 mm, needles: 16 mm, isolation: 6.5 mm, angled after 97 mm. Angle: 20 degree, autoclavable up to 134°C

❁ 506.5888.0

➈ Bipolar needle electrode (puncture electrode, bent at the top), # 04 For volume reduction of the soft palate and the lingual tonsils. Bent in front, isolated needles, ergonomic plastic handle, total length: 193 mm, needles: 19.5 mm, isolation: 9.5 mm, bent after 169 mm, angle: 55 degree, autoclavable up to 134°C

❁ 506.5887.0

Included in delivery: 2 pcs. Included in delivery: 2 pcs.

Included in delivery: 2 pcs.

Included in delivery: 2 pcs.

Included in delivery: 2 pcs. Included in delivery: 2 pcs.

Included in delivery: 1 pc.

Included in delivery: 1 pc.

Included in delivery: 1 pc.

Unless otherwise specified all electrodes are autoclavable and therefore reusable. For detailed information please see the operating instructions!

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 43


Smoke evacuation | AtmoSafe MedizinTechnik

AtmoSafe The most powerful smoke evacuation suction system!

44

No laser or HF surgery without smoke evacuation.


AtmoSafe

For the safe HF- and Laser surgery! ATMOS has introduced a smoke evacuation system for the OT – the AtmoSafe – a device which is used mainly in the laser and aesthetic surgery. Electrosurgical cutting and coagulation develop toxic fumes and build up unpleasant smells in the operating field - an obscured view and health risks are the result. The smoke evacuation system AtmoSafe protects both staff and patients from these toxic fumes, to the extent that doctors have a clear view in the OT, it prevents unpleasant smells, eliminates airborne viruses and carcinogenic substances. This cannot be done by a usual surgical suction device. The advantage of the AtmoSafe is, that it is almost noiseless and very economical to run due to the special ULPA filters.

Suction can be made available as and when required with the automatic activation of the device. ATMOS grants 6 years guarantee on the brush-free blower. Thanks to the unique combination of the special gas filter with the ULPA filter, staff and patients are also protected from papilloma viruses, ammoniac emissions and hydrogene cyanide vapours. ATMOS also offers a wide range of consumables for the AtmoSafe e.g. suction funnel, suction cannulae, prefilter and a standard rail with the relevant pivot mounted arm.

45


AtmoSafe MedizinTechnik

Main filter unit

Funnel

measures the airflow of the filter and defines the filter life, which is normally more than 35 hours. It consists of ULPA filter, three activated carbon filter layers and a gas filter.

for sucking off smoke gas.

Pre-adjustments

Trolley

The value for operation suction, basic suction and the follow-up time are individually adjustable. By pressing the scroll button the requested parameter to be adjusted, is selected.

for the mobile use.

Handling

Clip-on handle

Start button, manual Stop button, manual

REF 445.0063.0

Suction performance

Pre-filter (HEPA)

With 650 l/min noxious smoke gas is sucked off.

for a longer service life of the main filter

Filter life indication The indication of the filter life gives an overview on the actual filter status.

46

REF 000.0687.0

REF 950.0200.0

for slim-line handpieces

REF 445.0044.0


| Smoke evacuation | AtmoSafe MedizinTechnik

AtmoSafe

User package and accessories The smoke evacuation system for electro and laser surgery!

Creates a clear view in the operating field Prevents unpleasant smells

Removes airborne particles, viruses, gases, and carcinogenic substances Directly from the manufacturer!

AtmoSafe

AtmoSafe OT set Microprocessor-controlled suction unit for removing and filtering surgical smoke, including internal synchronous activation (ISA), automatic shut-down, filter control, and electronically controlled, brushless blower. Technical data: Pump performance: up to 650 l/min, Dimensions: (H x W x D): 210 x 410 x 370 mm

REF ❁ 445.0075.0

Included in delivery: basic unit, operating instructions, mains cable, Main filter device (ULPA), Prefilter set (HEPA), Hose Ø 22 mm, L = 2.10 m (not autoclavable), Hose Ø 22 mm, L = 2.10 m (50 x autoclavable), extraction tube, suction funnel, hose connector Ø 22 mm to Ø 22 mm, hose connector Ø 22 mm (M) to Ø 10 mm (M), hose connector Ø 22 mm (F) to Ø 10 mm (M), Joint arm (with 3 joints, stretched length approx. 1.3 m), 5 hose holders (hose Ø 22 mm), standard rail set (25 x 10 mm / 315 mm for lateral fixation)

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 47


| Smoke evacuation | AtmoSafe

Accessories for AtmoSafe Hose support for air hose inserted in standard rail,(stainless steel), Ø 22 mm ➀ Foot switch ➁ Foot switch (explosion-proof for OT) IPX8, with holding plate Joint arm with 3 joints for fixation to standard rail autoclavable, stretched length approx. 1.3 m, with 5 hose supports for hose Ø 22 mm Standard rail set Dimensions: 25 x 10 mm / 315 mm for internal fixation to AtmoSafe ➂ Trolley with table top and electrically conductive castors, 1 drawer, Dimensions (H x W x D) 800 x 512 x 550mm colour: RAL 7035 (light grey), Handles in RAL 5003 (sapphire-blue) ISA-power cord 2 m with non-heating plug and non-heating socket for device coupling ISA-power cord 40 cm with non-heating plug and non-heating socket for device coupling Interlink cable interface to laser- or HF-surgery Trolley 850 consisting of: Base with ESD-castors (front castors lockable) deposit board with handles drawer (to be arranged in any position) Dimensions (H x W x D): 85 x 55 x 64 cm Information brochure: "Smoke by-products in laser and HF surgery"

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 48

REF

❁ 445.0066.0 ❁ 445.0061.0 ❁ 445.0068.0 ❁ 445.0060.0 ❁ 445.0064.0 ❁ 445.0065.0

❁ 008.0800.0 ❁ 008.0806.0 ❁ 445.0073.0 ❁ 950.0200.0


MedizinTechnik

Consumables for AtmoSafe ➀ Main filter device (ULPA 99,9999% @ 0,01m / 3-steps gas filter) Change: after approx. 150 patients ➁ Pre-filter (HEPA) with connections Ø 22 mm (M/W), sterile, not autoclavable, 50 pcs., to be used for laser ablations Change: 1 x per patient Air suction handle for smoke-evacuation surgery handles, clip-on handle, air hose Ø 10 mm, L = 2,5 m, 25 pcs., Change: 1 x per patient ➂ Funnel flattened on one side, made of PP with connection for Ø 22 mm, autoclavable up to 134 °C, Change: after 50 x autoclaving Suction tube for suction hose Ø 22 mm, autoclavable up to 134 °C Change: after 50 x autoclaving Air hose Ø 22 mm, L = 2.10 m disposable, not autoclavable, made of E.V.A. Change: 1 x per patient Air hose Ø 22 mm, L = 2.10 m multiple applicable, autoclavable up to 132° C, made of Hytrel, Change: after 50 x autoclaving Air hose Ø 22 mm, L = 2.70 m multiple applicable, autoclavable up to 134° C, made of Hytrel, connecting sockets made of silicone Change: after 50 x autoclaving Air hose, internal Ø = 10 mm, L = 1.8 m autoclavable up to 132 °C, made of hytrel, connecting sockets made of silicone, Change: after 50 x autoclaving ➃ Hose connector, straight, Ø 22 mm (m) to Ø 22 mm (m) ➄ Hose connector, straight, Ø 22 mm (m) to Ø 10 mm (m) ➅ Hose connector, straight Ø 22 mm (f) to Ø 10 mm (m)

REF

❁ 445.0040.0 ❁ 445.0044.0 ❁ 445.0063.0 ❁ 000.0687.0 ❁ 445.0055.0 ❁ 005.0200.0 ❁ 005.0203.0 ❁ 005.0201.0 ❁ 005.0204.0 ❁ 000.0683.0 ❁ 000.0689.0 ❁ 000.0688.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 49


| Smoke evacuation | AtmoSafe

AtmoSafe

Basic unit

Creates a clear view in the operating field Prevents unpleasant smells

Removes airborne particles, viruses, gases, and carcinogenic substances Directly from the manufacturer!

AtmoSafe

AtmoSafe - Basic unit Microprocessor-controlled suction unit 230 V~ for removing and filtering surgical smoke, including internal synchronous activation (ISA), automatic shut-down, filter control, and electronically controlled, brushless blower Technical data: Pump performance: up to 650 l/min, Dimensions: (H x W x D): 210 x 410 x 370 mm

REF ❁ 445.0000.0

Included in delivery: basic unit, operating instructions, mains cable, Main filter device (ULPA), Prefilter set (HEPA), Hose Ø 22 mm, L = 2.10 m (not autoclavable), Hose Ø 22 mm, L = 2.10 m (50 x autoclavable), extraction tube, suction funnel, hose connector Ø 22 mm to Ø 22 mm, hose connector Ø 22 mm (M) to Ø 10 mm (M), hose connector Ø 22 mm (F) to Ø 10 mm (M),

Technical data

AtmoSafe basic device

Operating time

Continuous operation

Noise level

Power consumption Voltage

52 dB (A) @ 1m (acc. to ISO 7779) approx. 400 W

AtmoSafe Europe: 230 V~ 50/60 Hz; AtmoSafe World switchable: 100 V~ 50-60 Hz or 120 V~ 50-60 Hz or 230 V~ 50-60 Hz

Dimensions (H x W x D)

210 x 410 x 370 mm (without filter); 420 mm (with filter)

Classifications

protection class (EN 60601-1): I; degree of protection: type CF defibrillator protected; protection category: IPX 0; OT-Foot switch: IPX8; Office-Foot switch IPX1; class I; (acc. to appendix IX, directive 93/42/EEC)

Weight

Appliance air flow with 1.8 m hose

14 kg

Controlled 650 l/min ±10%; Turbo up to 800 l/min free blower flow 1600 l/min

The stated technical data are valid at the moment of printing, and are subject to change!

50


MedizinTechnik

Surgical smoke evacuation for the electrical (HF-laser) incision

aerosols

gases

aggregates

H2O-steam

agglomerates

CO2 /CO

secondary particles

NH3 / HCN / H2S

primary particles vapours droplets tissue residues

volatile organic compounds

tissue

pyrolysis products with the medical use of laser

PDFURSKRWRJUDSK RI WKH Âż OWHU VXUIDFH showing deposited contaminants

The situation: Electrosurgical devices and lasers for the coagulation of tissue are nowadays part of the standard procedure and operating processes can no longer be imagined without these instruments. Arising problems: Unfortunately these surgical inventions are often accompanied by considerable disadvantages. The application of electrosurgery leads to the formation of toxic gases, harmful aerosols and transmission of human viruses to the endangering of health of both patients and operating personnel. The formation of smoke also leads to sight obstruction in connection with unpleasant odours. 7KH SUHVV HYHQ UHSRUWHG WKDW IRU WKH ¿ UVW WLPH ODU\QJHDO SDSLOORPDWRVLV KDV EHHQ UHFRJQLVHG DV DQ RFFXSDWLRQDO GLVHDVH RI nurses working in operating theatres. A high risk of disease transmission has been proven several times during the removal of papilloma and condyloma and the resulting infectiousness due to laser fumes. Hence laser fume extraction is indispensable for the protection of the operating personnel. (Source: Laryngo-Rhino-Otology 2003; 82: page 790-793 – Georg Thieme Verlag Stuttgart) To meet these requirements, the implementation of smoke suction extraction systems during treatment involving lasers or electrosurgical instruments is now prescribed in the USA and in many parts of Europe. This trend is proceeding around the world. ATMOS provides the solution: With application of the AtmoSafe the operating personnel are supplied and protected with an effective, economic and medically reliable smoke extraction unit. Unrestricted safety for patients and personnel in the operating theatre is now guaranteed! This is accomplished by means of the flow rate of 650 l/min – equivalent to 10 times the capacity of the most powerful surgical suction extraction.

The use of a smoke evacuation system to prevent damage to health is an international standard of the health and safety at work guidelines and is urgently recommended for your safety by: Â’ Â’ Â’ Â’

NBOSH National Board of Occupational Safety and Health, Schweden NIOSH National Institute for Occupational Safety and Health, USA OSHA Occupational Safety and Health Administration, USA ANSI American National Standard for the Safe Use of Lasers in Health Care facilities, USA

51


Smoke evacuation | AtmoSafe

Information brochure smoke by-products

1. Is normal operating theatre ventilation adequate for evacuating smoke? No, the rate of air circulation in the room - up to 24 x volume/hour - is not sufficient to evacuate locally generated aerosols and gases; the user is still exposed to dangerous laser smoke. 2. Is a normal room suction system (a central vacuum) not good enough? No, the rate of room suction in an operating theatre is too low, at 30-40 l/min. Research has shown that a minimum of 400-600 l/min. is required in the operating field. 3. How high is the risk of becoming infected from biological substances during an operation? Research is currently being undertaken to ascertain the degree of danger that exists from using different lasers and electrosurgical instruments. It has been proven that infectious particles can reach theatre staff and thereby create an acute risk of infection via the mucous membranes and respiratory tracts. 4. Are the particles generated during an operation really dangerous? Airborne viruses such as papilloma viruses, proteins such as prions (BSE pathogens) and other airborne bacteria and funghi are dangerous substances which can lead to direct infection. 5. Do surgical face masks help protect the operating staff? No, surgical face masks offer theatre staff no protection against airborne particles. These masks were designed to protect patients from droplet infections emanating from the operating team. Up to 25 % of the air inhaled in gets through the mask. 6. Are there other reasons for carrying out localised smoke evacuation, apart from the risk of infection? The use of local smoke evacuation, when carried out during endoscopies, minimally invasive surgery and partially open and closed body cavities, gives optimum visibility.

52

Extracted by: „Smoke-by products in the laser and HF surgery“ An information brochure for staff and patients. Please request our information brochure: Phone: +49 7653 689-374 ApplicationSolutions@atmosmed.com

7. How do doctors react to smoke evacuation devices? Smoke evacuation enjoys a high level of acceptance among medics, as they no longer have to contend with an obscured view in the operating field. 8. What effects do particles and gases have on the patient? During laparoscopies in particular, toxic gases diffuse into the patient‘s bloodstream. Small airborne particles in this VPRNH PHDVXULQJ IURP WR P FDXVH RFXODU and upper respiratory tract irritation. 9. Is there a risk to the patient? Medical staff should be aware of the risks to the patient from laser use and diathermic smoke generation during an operation. Some of the smoke inside a closed abdominal cavity can lead to an increase in methaemoglobin content, which reduces the capacity of body tissue to absorb oxygen. 10. Does the suction device have to be operated separately? No, the suction device runs in the background; assistant theatre staff do not need to devote any resources to operating it. The smoke evacuation unit is activated automatically when needed. 11. How high are the running costs of local smoke evacuation? The operating costs of the filter system are less than 1 Euro per surgical procedure and the filter unit has a life of up to 52 hours, depending on flow. 12. Do lasers deactivate dangerous airborne viruses? No, research on retroviruses has shown that infectious viruses and constituents of virus DNA are carried in laser smoke. So it is possible to be infected, for example, by papilloma viruses in the laser smoke.


MedizinTechnik

ATMOS ZV 60 / ATMOS ZD 60 Vacuum regulator and suction systems for central vacuum supply and central compressed air supply

For anaesthesia and intensive care – the perfect system solution for demanding users.

53


ATMOS ZV / ZD 60

ATMOS ZV 60 / ATMOS ZD 60 You are familiar with the situation: You need a reliable and powerful suction system!

Bedridden patients are treated by the in-house vacuum system during their hospital stay. The vacuum supply is adequate but it must be reliably controlled. The solution: ATMOS, as one of the leading manufacturers of suction units worldwide, has been looking into this matter and can now present you with the ATMOS ZV 60 and ATMOS ZD 60. This system solution stands for safety due to - Perfect meter-reading - Suction control at a glance - The cut-off valve for immediate interruption of vacuum supply

54

Furthermore, the single docking station is suitable for economically designed treatment processes. The secrete jars can be used for both, the central vacuum system and in portable suction systems. An advantage is that the nursing staff do not have to be instructed in the use of different jar systems and that the handling of this system is very simple and convenient.


MedizinTechnik

ATMOS ZV 60 / ATMOS ZD 60

Max. flow, 55 l/min (+/-5 l) For all applications in the OT and on the ward. The damped vacuum gauge is easy to read and suction is controlled at a glance.

Single Docking Station for connecting the ATMOS DDS containers. By now the approved Direct Docking Stations are also available for connection to the standard rail system (25x10 mm or 30x10 mm).

The multiple-use container system: The direct docking systems from ATMOS! No more cumbersome tube connections.

55


| Suction system for vacuum and compressed air | ATMOS ZV/ZD 60

ATMOS ZV / ZD 60

Central vacuum and compressed air supply

maximum flow 55 l/min (±5 l) perfect meter-reading

suction control at a glance

cut-off valve for immediate vacuum interruption

ATMOS ZV/ZD 60

ATMOS ZD 60 Vacuum suction regulator for the central compressed air connection, with vacuum regulator, vacuum display and stop valve, CPC coupling for connecting hose, device connecting hose NIST EN 739, incl. standard rail support Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure

REF ❁ 320.0800.0

Included in delivery: basic unit, operating instructions

ATMOS ZV 60 Vacuum suction regulator for the central vacuum connection, with vacuum regulator, vacuum display and stop valve, CPC coupling for connecting hose, device connecting hose NIST EN 739, incl. standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure Included in delivery: basic unit, operating instructions

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 56

❁ 320.0750.0


MedizinTechnik

ATMOS ZD 60 SDS-1 set Mobile suction unit for connection to the central compressed air with vacuum controller, vacuum display and stop valve, CPC coupling for connecting hose with NIST EN 739 connection, including standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure

REF

❁ 320.0745.0

Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions

ATMOS ZV 60 SDS-1 set Mobile suction unit for connection to the central vacuum system Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions

ATMOS ZD 60 SDS-2-Set Mobile suction unit for connection to the central compressed air with vacuum controller, vacuum display and stop valve, CPC coupling for connecting hose with NIST EN 739 connection, including standard rail support. Technical data: Vacuum performance 0...-85 kPa, suction performance max. 55 l/min ± 5 l/min, depending on supply pressure

❁ 320.0740.0

❁ 320.0720.0

Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions, stainless steel trolley (with 2 standard rails)

ATTENTION: DDS canister with lid must be ordered separately!

ATMOS ZV 60 SDS-2-Set Mobile suction unit for connection to the central vacuum system

Included in delivery: basic unit, Single-Docking-Station (SDS), operating instructions, stainless steel trolley (with 2 standard rails)

❁ 320.0730.0

Please order connecting hoses separately!

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 57


| Suction system for vacuum and compressed air | ATMOS ZV/ZD 60

Accessories for completing the ZV / ZD versions ➀ Trolley Stainless steel frame with plastic castors, dimensions (with castors) H x W x D: 844 x 450 x 435 mm, roller Ø 55 mm ➁ Single-Docking-Station (SDS) Single-docking-station enables the use of DDS-canisters in connection with ZV / ZD systems. Attention: please order canister with lid separately! Hose C 401 ground connection canister Accessories for ATMOS ZD / ZV 60

Connection hoses for vacuum ➂ Connection hose 1.5 m for ZV 60 (DIN adapter) Connection hose 3 m for ZV 60 (DIN adapter) Connection hose 5 m for ZV 60 (DIN adapter)

REF

❁ 320.0450.0 ❁ 320.0640.0

❁ 340.0083.0

❁ 320.0765.0 ❁ 320.0832.0 ❁ 320.0831.0

➂ ➃ Connection hose 1.5 m for ZV 60 (British standard)

❁ 320.0766.0

Connection hose 5 m for ZV 60 (British standard)

❁ 320.0827.0

Connection hose 3 m for ZV 60 (British standard)

❁ 320.0834.0

➃ ➄ Connection hose 1.5 m for ZV 60 (AFNOR connection)

❁ 320.0844.0

Connection hose 5 m for ZV 60 (AFNOR connection)

❁ 320.0823.0

Connection hose 3 m for ZV 60 (AFNOR connection)

❁ 320.0839.0

➄ ➅ Connection hose 1.5 m for ZV 60 (US OHMEDA connection)

❁ 320.0846.0

Connection hose 5 m for ZV 60 (US OHMEDA connection)

❁ 320.0826.0

Connection hose 3 m for ZV 60 (US OHMEDA connection)

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 58

❁ 320.0836.0


MedizinTechnik

➀ Connection hose 1.5 m for ZV 60 (Scandinavian connection)

❁ 320.0843.0

Connection hose 5 m for ZV 60 (Scandinavian connection)

❁ 320.0822.0

Connection hose 3 m for ZV 60 (Scandinavian connection)

❁ 320.0840.0

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 59


| Suction system for vacuum and compressed air | Accessories for ATMOS ZD / ZV 60

Supply hoses for compressed air ➀ Connection hose 1.5 m for ZD 60 (DIN adapter) Connection hose 3 m for ZD 60 (DIN adapter) Connection hose 5 m for ZD 60 (DIN adapter)

REF

❁ 320.0815.0 ❁ 320.0833.0 ❁ 320.0830.0

➀ ➁ Connection hose 1.5 m for ZD 60 (British standard)

❁ 320.0816.0

Connection hose 5 m for ZD 60 (British standard)

❁ 320.0829.0

Connection hose 3 m for ZD 60 (British standard)

❁ 320.0835.0

➁ ➂ Connection hose 1.5 m for ZD 60 (AFNOR)

❁ 320.0845.0

Connection hose 5 m for ZD 60 (AFNOR)

❁ 320.0824.0

Connection hose 3 m for ZD 60 (AFNOR)

❁ 320.0838.0

➂ ➃ Connection hose 1.5 m for ZD 60 (US OHMEDA)

❁ 320.0847.0

Connection hose 5 m for ZD 60 (US OHMEDA)

❁ 320.0825.0

Connection hose 3 m for ZD 60 (US OHMEDA)

❁ 320.0837.0

➃ ➄ Connection hose 1.5 m for ZD 60 (Scandinavian)

❁ 320.0842.0

Connection hose 5 m for ZD 60 (Scandinavian)

❁ 320.0821.0

Connection hose 3 m for ZD 60 (Scandinavian)

Please contact us via: ApplicationSolutions@atmosmed.de | Phone: +49 7653 689-374 | Fax: +49 7653 68986-374 60

❁ 320.0841.0


MedizinTechnik

ATMOS Service worldwide

7HFKQLFDO WUDLQLQJ 0DLQWHQDQFH DQG VHUYLFLQJ 6HUYLFH DQG UHSDLU

We offer you complete support so you can care for your patients! 61


MedizinTechnik

Training and instructions Â’ ,QVWUXFWLRQV IRU XVH

Â’ 3URGXFW WUDLQLQJ

The ATMOS product and introductory training courses will clearly and comprehensively prepare your staff for practical operation. We ensure that important knowledge and skills concerning maintenance and care are communicated and if required, this training can be carried out on customer premises.

Introductory training courses for ATMOS products )XQGDPHQWDO HOHPHQWV RI $7026 SURGXFWV DQG V\VWHP DSSOLFDWLRQV $SSOLFDWLRQ LQ FRPSOLDQFH ZLWK XVHU LQVWUXFWLRQV IXQFWLRQLQJ PRGH DXWKRULVHG DFFHVVRULHV RSSRUWXQLWLHV IRU FRPELQDWLRQ ZLWK RWKHU SURGXFWV VDIHW\ IXQFWLRQV FDUH PDLQWHQDQFH DQG K\JLHQH PHDVXUHV SUDFWLFDO H[HUFLVH Confirmation of participation in a course by means of instruction certificate!

Location

Product

Price

Participants

2Q VLWH

6XFWLRQ SURGXFWV1) WDEOH WRS XQLWV1) FKDLUV1) XQLWV1)

$FFRUGLQJ WR DJUHHPHQW

PD[

Target group: 8VHUV RI $7026 SURGXFWV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU (Appoints according to agreement).

Technical product training for ATMOS Products ,QLWLDO WUDLQLQJ LQ XQLW DSSOLFDWLRQ EDVLF WHFKQLFDO NQRZOHGJH RQ WKH XQLW PDLQWH QDQFH LQVSHFWLRQ DQG FDUH K\JLHQH PHDVXUHV WLSV IRU WURXEOH IUHH RSHUDWLRQ UHSDLU ZRUN SUDFWLFDO H[HUFLVH Confirmation of participation in the course by means of certificate!

Location /HQ]NLUFK 2Q VLWH

Duration

Price

Participants

GD\

1)

±

GD\

1)

PD[

Target group: 0HGLFDO WHFKQLFLDQV ZRUNLQJ LQ KRVSLWDOV DQG FOLQLFV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU 3DUWLFLSDQW LV D PHGLFDO WHFKQLFLDQ (Appointment according to agreement).

1)

62

)RU SULFHV DQG VSHFLDO RIIHUV SOHDVH FRQWDFW \RXU ORFDO GHDOHU


z Reprocessing

z Consulting

Our regular training courses dealing with the preparation of suction units provide our partners with the necessary know-how required to prepare ATMOS medical products both functionally and hygienically.

Reprocessing training courses for ATMOS small suction units Reprocessing in accordance with BVMed- und ATMOS guidelines, legal basis (MPG (Medical Product Law), RKI (Robert Koch Institute) technical principles, simple repair work as well as practical exercise. Confirmation of participation in the training course by means of certificate!

Location /HQ]NLUFK 2Q VLWH

Duration

Price

Participants

GD\

1)

Âą

GD\

1)

PD[

Target group: 6HUYLFH WHFKQLFLDQV ZLWK HOHFWUR WHFKQLFDO WUDLQLQJ DQG PHGLFDO WHFKQLFLDQV Prerequisites: &RPSDQ\ SDUWLFLSDWLQJ LV DQ $7026 FXVWRPHU 3DUWLFLSDQW FDQ SURYH WKDW KH VKH SRVVHVVHV HOHFWRU WHFKQLFDO VNLOOV &HUWLILFDWLRQ LQ DFFRUGDQFH ZLWK ,62

The new conference room in the ATMOS Academy

Advice and services all around your ATMOS products Â’ Â’ Â’ Â’

1)

&HUWLILFDWH RI YDOXDWLRQ 9DOXH UHWHQWLRQ UHSRUW &HUWLILFDWH LQ WKH VFRSH RI LQGHSHQGHQW SUHVHUYDWLRQ RI HYLGHQFH 3URMHFW DFFRPSDQ\LQJ DQG DGYLVRU\ DFWLYLWLHV $GYLFH ZLWK UHJDUG WR FOHDQLQJ FDUH DQG ZDWHU K\JLHQH

)RU SULFHV DQG VSHFLDO RIIHUV SOHDVH FRQWDFW \RXU ORFDO GHDOHU 63


MedizinTechnik

Maintenance and inspection We recommend preventive maintenance – because malfunction means downtime! 2XU WUHDWPHQW XQLWV DUH GHVLJQHG IRU UHOLDEOH DQG GXUDEOH XVH LQ \RXU HYHU\GD\ ZRUN :H GHPDQG KLJK VWDQGDUGV RI K\JLHQH DQG VDIHW\ RI RXU GHYLFHV FRPELQHG ZLWK WKH FRPSOLDQFH RI VWDWXWRU\ SURYLVLRQV 7KHUHIRUH WKRXVDQGV RI GRFWRUV UHO\ RQ WKH GXUDELOLW\ RI RXU SURGXFWV HYHU\ VLQJOH GD\ :H ZRXOG DOVR OLNH WR EH DYDLODEOH IRU \RX DW DQ\ WLPH DIWHU VDOHV LQ RUGHU WR VHFXUH WKH YDOXH RI \RXU LQYHVWPHQW ,QVSHFWLRQ DQG PDLQWHQDQFH DUH SUHYHQWLYH PHDVXUHV H J H[FKDQJH RI ZHDU DQG WHDU SDUWV LQ WLPH LQ RUGHU WR DYRLG H[SHQVLYH GRZQWLPHV ,QVSHFWLRQ DQG PDLQWHQDQFH SURYLGH WKH EDVLV IRU HOHFWULFDO VDIHW\ DQG IRU D K\JLHQLFDOO\ SHUIHFW SURGXFW ,W LV D PDWWHU RI VDIHW\ IRU \RXU SDWLHQWV 2XU PDLQWHQDQFH FRQWUDFWV PHHW OHJDO UHTXLUHPHQWV ZLWK UHJDUG WR VDIHW\ UHODWHG LQVSHFWLRQV HQVXUH D SHUIHFW ZRUNIORZ DQG SURYLGH D KLJK VWDQGDUG LQ K\JLHQH DQG WHFKQLFDO VDIHW\ :LWK RXU SUHPLXP FRQWUDFW ZH JXDUDQWHH D PD[LPXP UHVSRQVH WLPH RI K Legal requirements to be fulfilled by the treating doctor Safety-related inspections Ä7KH RSHUDWRU RI PHGLFDO SURGXFWV KDV WR DELGH E\ WKH VDIHW\ UHODWHG FRQWUROV SUHVFULEHG E\ WKH PDQXIDFWXUHU DQG LQ DFFRUGDQFH WR WKHLU VSHFLILFDWLRQV DQG JHQHUDO UHJXODWLRQV 7KHVH QHFHVVDU\ PDLQWHQDQFH PHDVXUHV KDYH WR EH SHUIRUPHG ZLWKLQ WKH GHDGOLQH VWDWHG DQG KDYH WKHP LPSOHPHQWHG ³ *HUPDQ UHJXODWLRQ

6HUYLFH

'HVFULSWLRQ

$QQXDO VHUYLFH LV SHUIRUPHG RQ VLWH IUHH RI FKDUJH

$ERXW IRXU ZHHNV LQ DGYDQFH $7026 DUUDQJHV DQ DSSRLQWPHQW ZLWK \RX 7KH KRXUV RI ZRUN DQG WKH WUDYHO FRVWV DUH LQFOXGHG

)XQFWLRQDO FKHFN

$OO WKH IXQFWLRQV RI WKH FRPSOHWH V\VWHP DQG WKH EXLOW LQ PRGXOHV DUH FKHFNHG $Q LQVSHFWLRQ RI DOO WKH PHFKDQLFDO SDUWV LV SHUIRUPHG $OO WKH FDEOHV DQG SOXJ LQ FRQQHFWRUV DUH FKHFNHG

6DIHW\UHOHYDQW FKHFN

6DIHW\ UHOHYDQW FKHFNV LQFOXGLQJ HOHFWULFDO LQVSHFWLRQ DFFRUGLQJ WR † 0HGLFDO 'HYLFHV 2SHUDWRU 2UGLQDQFH DFFRUGLQJ WR ',1 (1

9

9*

9*

)LWWLQJ RI 'XULQJ WKH DQQXDO PDLQWHQDQFH FKHFN ZH RSWLRQV IUHH RI ZLOO UHWUR¿ W RSWLRQV IUHH RI FKDUJH ZKLFK FKDUJH PD\ EH RUGHUHG IURP RXU FDWDORJXH

9*

GLVFRXQW

)RU DOO VSDUH SDUWV DQG MRXUQH\

9

3URORQJDWLRQ RI WKH JXDUDQWHH IRU DQRWKHU \HDU

\HDU LQVWHDG RI D \HDU JXDUDQWHH IRU D PDLQWHQDQFH FRQWUDFW ZKLFK LV PDGH ZKHQ D QHZ $7026 6 LV ERXJKW

9

$GYLFH SHU KHOS ZLWK WHFKQLFDO SUREOHPV LQ DYDLODEOH WHOHSKRQH DQG IUHH RI FKDUJH SHU WHOHSKRQH RU YLD H PDLO H PDLO GXULQJ EXVLQHVV KRXUV

64

$7026 6WDQGDUG

Your advantages: „ 5HGXFHV GRZQWLPHV „ &RQVHUYDWLRQ RI YDOXHV RI \RXU LQYHQWRU\ „ 'LVFRXQWV RQ UHSDLUV DQG QR FDOO RXW IHH „ 4XLFN WURXEOHVKRRWLQJ „ 3URORQJDWLRQ RI ZDUUDQW\ „ 3UHVFULEHG VDIHW\ FKHFN DFFRUGLQJ WR

† 0HGLFDO 'HYLFHV 2SHUDWRU 2UGLDQFH


Reprocessing of small ATMOS suction devices

The reprocessing of ATMOS suction devices is our speciality!

6FRSH 'HYHORSPHQW PDQXIDFWXUH VDOHV DQG VHUYLFH RI PHGLFDO GHYLFHV IRU WUHDWPHQW GLDJQRVWLFV DQG WKHUDS\ LQ FOLQLF SUDFWLFH DQG KRPHFDUH DV ZHOO DV reprocessing of suction devices

:H DUH FHUWLILHG IRU WKH UHSURFHVVLQJ RI VXFWLRQ GHYLFHV DFFRUGLQJ WR (1 ,62 DQG (1 ,62 6HQG \RXU $7026 VXFWLRQ GHYLFH WR RXU VHUYLFH GHSDUWPHQW ZLWK WKH UHPDUN ³UHSURFHVVLQJ´ <RXU GHYLFH ZLOO EH SURFHVVHG HIILFLHQWO\ DQG FRPSHWHQWO\ ZLWK WKH DSSURSULDWH K\JLHQH SURFHGXUH

ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone: +49 7653 689-222 Fax: +49 7653 689-292 Service@atmosmed.de

Our Service team: Eckhardt Stender, Olaf Marx, Michael Weis, Egon Blessing, Christian König, Klaus Bendkowski, Kian Schwuchow (back) Jean-Luc Imhoff, Manuela Schmidt, Claudia Tritschler, Kerstin Wehrle, Winfried Link (front)

65


ATMOS Partners worldwide Around the globe. Around the clock. Anytime.

66

ATMOS Partners worldwide

MedizinTechnik


MedizinTechnik

ATMOS Sales & Service team Managing Director Sales

Sales Manager Germany

Headquarters:

Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch

Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch

Ludwig-Kegel-Str. 12, 14-16, 18

Maik Greiser Phone

+49 7653 689 215

E-Mail

MGreiser@atmosmed.de

Area Sales Manager Ralf Kühnemund France, Benelux, Italy, USA, Canada, Marocco, Tunisia, Algeria, South africa Phone +49 7653 689-311 E-Mail RKuehnemund@atmosmed.de

Area Sales Manager Axel Kanefeyer NE-Europ, Switzerland, Austria, Middel East, China, Egypt Phone +49 7653 689-330 E-Mail

Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch Bernd Schley Sales Phone E-Mail

DGebele@atmosmed.de

Regional Sales Manager Matthias Straub Asia & Ozeanien Phone E-Mail

Region North

Max-Nonne-Str. 45

Jan Carmienke Service North E-Mail J.Carmienke@agh-diagnostics.de

22419 Hamburg/Germany Tel: +49 40 5332 685-0 Rainer Holzem Teamleader Sales North (SI) Phone Mobile E-Mail

Daniel Gebele Great Britain, Spain, Portugal, Latin america

E-Mail

+49 7653 689-355 BSchley@atmosmed.de

Region North

Area Sales Manager +49 7653 689-340

+ 49 4231 936155 + 49 171 7640648 RHolzem@atmosmed.de

Jochen Kaufels Sales representative North (AS) Nordstr. 28a 06862 Dessau-Roßlau Phone +49 34901 947 58 Fax –59 Mobile + 49 160 96367338 E-Mail JKaufels@atmosmed.de

Ulrich Kraut Service Northwest E-Mail UKraut@atmosmed.de

Matthias Wolf Service Northeast E-Mail MWolf@atmosmed.de

Region South Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch Roland Vöstel Teamleader Sales South (SI) Phone +49 7653 689-310 E-Mail RVoestel@atmosmed.de

+60 (3) 6274 7400 MStraub@atmosasia.com

Area Sales Manager Andreas Käfer Sales representative Southwest (SI) Schwaigernerstr. 2 75050 Gemmingen Phone +49 7267 914610 Fax –629 Mobile +49 175 2905410 E-Mail AKaefer@atmosmed.de

Philipp Rellermeier Indien, Asien, Oceania, Central Africa Phone +49 7653 689-325 E-Mail PRellermeier@atmosmed.de

Sales Support Manager

Region South Horst Delling Service Southeast E-Mail HDelling@atmosmed.de

Wolfgang Heiß Sales representative Southeast (SI) Zeisigweg 13 86420 Diedorf-Anhausen Phone +49 8238 958342 Fax –624 Mobile +49 171 3049490 E-Mail WHeiss@atmosmed.de

Julia Schumacher Phone E-Mail

ATMOS MedizinTechnik GmbH & Co. KG Tel. +49 7653 689-222 E-Mail service@atmosmed.de

Business Unit Manager Sales (AS)

AKanefeyer@atmosmed.de

Phone

79853 Lenzkirch

Michael Schindler Sales Manager Germany Phone +49 7653 689 350 Mobile +49 151 11714220 E-Mail MSchindler@atmosmed.de

+49 7653 689-327 JSchumacher@atmosmed.de

Region Middle Luisenstraße 21 53721 Siegburg Georg Grünefeld Teamleader Sales West (SI) Phone +49 2241 1279146 Mobile +49 171 3616181 E-Mail GGruenefeld@atmosmed.de

Region Middle Robert Bach Service West E-Mail

RBach@atmosmed.de

Sven Schlimgen Sales representative West (AS) Phone +49 2241 1461253 Mobile +49 170 7632967 E-Mail SSchlimgen@atmosmed.de

SI = System Integration AS = Application Solutions

67


MedizinTechnik

Your contact person at the parent company in Lenzkirch Business Unit Manager OEM

Business Unit Manager Application Solutions

Business Unit Manager System Integration

Ulrich Jehle Tel. +49 7653 689- 600 UJehle@atmosmed.de

Urich Jehle Phone +49 7653 689-600 UJehle@atmosmed.de

Jรถrg Pahlke Phone +49 7653 689-642 JPahlke@atmosmed.de

Product Manager OEM

Product Manager Suction devices and Drainage systems Simon Wegner Phone +49 7653 689-644 SWegner@atmosmed.de

Product Manager ENT

Product Manager Suction devices and Drainage systems Julian Fitz Phone +49 7653 689-643 JFitz@atmosmed.de

Junior Product Manager ENT

Dominik Birkenmaier Tel. +49 7653 689- 651 DBirkenmaier@atmosmed.de

Jenny M. Doan Phone +49 7653 689-647 JDoan@atmosmed.de

Florian Betz Phone +49 7653 689-641 FBetz@atmosmed.de Product Manager Gynaecology Daniel Notheis Phone +49 7653 689-646 DNotheis@atmosmed.de

The Managing Directors a strong family team Therewith the generation change has been initiated. From left to right:

Maik Greiser Peter Greiser Gerlinde Greiser Frank Greiser

68


MedizinTechnik

Europe

Endovision B.V.B.A.

Dräger Medical Belgium N.V.

Tommy De Saeger

Marc Notez

Arseus Health

Eric Salden

Belgium / Luxembourg

Phone +32 24626211 Fax +32 26095240 E-Mail tommy.desaeger@draeger.com www.draeger.com Belgium / Luxembourg

Phone +32 475 510559 Fax +32 3 8252370 E-Mail Eric.salden@arseus-medical.be www.arseus-medical.be Belgium / Luxembourg

Medical Technic Eng. Ltd.

Seelen Care ApS

Otoplug OY

Phone +32 1640 7010 Fax +32 1640 7066 E-Mail info@endovision.be

Lise von Seelen Weis

Dimitar Konov

Kerkko Penttilä

Bulgaria

Phone +45 70 9742229 Fax +45 70 97401396 E-Mail seelen@seelen-care.dk www.seelen-care.dk Denmark

Phone +358 33 647215 Fax +358 33 647815 E-Mail NHUNNR SHQWWLOD#RWRSOXJ ¿ ZZZ RWRSOXJ ¿ Finland

ATMOS MEDICAL FRANCE

Papapostolou Ltd.

ATMOS Medical Ltd.

Phone +31 359 2 9712845 Fax +31 359 2 8734943 E-Mail konov@mte-bg.com

Julie Siafarika

Nicolas Perusin Phone +33 491 443294 Fax +33 491 443968 E-Mail atmosfrance@atmosfrance.fr www.atmosmed.fr France MedizinTechnik

Phone +30 210 6790000 Fax +30 210 6790100 E-Mail jsiafarika@papapostolou.gr www.papapostolou.gr Greece

David Butchart Phone +44 1489 611 739 Fax +44 1489 611 612 E-Mail david.butchart@atmosmedical.com www.atmosmedical.com Great Britain MedizinTechnik

69


MedizinTechnik

Europe

ATMOS Medical Ltd.

ICEPHARMA

Arnar Adalsteinsson

David Butchart MedizinTechnik

ATMOS ITALIA S.R.L

Matteo Bertoletti

Phone +44 1489 611 739 Fax +44 1489 611 612 E-Mail david.butchart@atmosmedical.com www.atmosmedical.com Ireland

Phone +354 5 204310 Fax +354 5 408001 E-Mail arnar@icepharma.is www.icepharma.is Iceland

Phone +39 02 48402262 Fax +39 02 48402506 E-Mail m.bertoletti@atmosmed.it www.atmosmed.it Italy

INEL Medicinska Tehnika

UAB Biomedika

Pharma-Cos. Limited

Vilko Klindic

Kestutis Liegus

Phone +385 165 20546 Fax +385 165 20966 E-Mail vilko.klindic@inel-mt.hr www.inel-mt.hr Croatia

Phone +370 8 5 2709055 Fax +370 8 5 2709056 E-Mail kestutis@biomedika.lt www.biomedika.lt Lithuania

Vinora d.o.o. Skopje

Entercare BV

MedizinTechnik

Marcel K. Mifsud Phone +356 21 441977 Fax +356 21 441388 E-Mail info@pharma-cos.com www.pharma-cos.com Malta

Tefa-Portanje B.V.

Mirjam Schouten Alexandar Nikolovski Phone +389 2 3177914 Fax +389 2 3177914 E-Mail vinoramk@unet.com.mk www.vinora.com.mk Macedonia

Phone +31 348 420142 Fax +31 348 420142 E-Mail lchoogstraten@entercare.nl www.entercare.nl Netherlands

OrtoMedic AS

Neuroth AG

Morten Hansen Phone +47 67 518600 Fax +47 67 518599 E-Mail mh@ortomedic.no www.ortomedic.no Norway 70

Luc C. Hoogstraten

Karl Osobsky Phone +43 1 5455 013100 Fax +43 1 5455 013500 E-Mail karl.osobsky@neuroth.at www.neuroth.at Austria

Phone +31 348 495 882 Fax +31 348 495 799 E-Mail m.schouten@tefa-portanje.opg.nl http://www.tefa-portanje.nl Netherlands

Medicus App. i Instrumenty Medyczne

Janusz Surma Phone +48 71 3472100 Fax +48 71 3472111 E-Mail jsurma@medicus.wroc.pl www.medicus.wroc.pl Poland


MedizinTechnik

Europe

Medist S.R.L.

ATMOS Medica S.L.

Daniel Romo

Bogdan Niculescu MedizinTechnik

OOO ATMOS Medikal

Andrey Sorokin

Phone +34 902193580 Fax +34 937414672 E-Mail dromo@atmosmed.es www.atmosmed.es Portugal

Phone +40 21 4115003 Fax +40 21 4105446 E-Mail bogdan.niculescu@medist.ro www.medist.ro Romania

Phone +7 495 2580894 Fax +7 495 2580894 E-Mail atmosmed@telsycom.ru www.atmosmed.ru Russia

ATMOS Medical AG

ULTRAMED s.r.o.

Dräger Slovenija d.o.o.

Juraj Varga

Jacky Noll Phone +41 616914151 Fax +41 61 6910992 E-Mail info@atmosmed.ch www.atmosmed.ch Switzerland

MedizinTechnik

ATMOS Medica S.L.

MedizinTechnik

Robert Pristavec

Phone +421 456761318 Fax +421 456761317 E-Mail juraj.varga@ultramed.sk www.ultramed.sk Slovakia

Phone +386 4 561 2263 Fax +386 1 561 2264 E-Mail robert.pristavec@draeger.com www.draeger.com/slovenija Slovenia

HIST Medical s.r.o.

ATMOS Medikal Ltd.

Jaromir Hink

Daniel Romo

Timur Arslan

Phone +34 902193580 Fax +34 937414672 E-Mail dromo@atmosmed.es www.atmosmed.es Spain

Phone +420 737329835

Czech Republic

Phone +90 2165756414 Fax +90 216575635 E-Mail TArslan@atmosmed.de www.atmosmed.de Turkey

ATMOS HÖR-KA KFT.

TAHAT

Costas Papaellinas Org.

MedizinTechnik

E-Mail hist.medical@seznam.cz

Siarhei Shmyk

István Nyitó Phone +36 1 335 6028 Fax +36 1 335 6028 E-Mail inyito@atmosmed.hu www.atmosmed.hu Hungary

MedizinTechnik

Phone +375 17 296 54 99 Fax +375 17 296 39 99 E-Mail tahat@mail.bn.by Belarus

MedizinTechnik

Nicos Mylonas Phone +357 22 863100 Fax +357 22 675136 E-Mail nicos.mylonas@papaellinas.com www.papaellinas.com Cyprus 71


MedizinTechnik MedizinT

North- / South America

ATMOS Inc.

DEWIMED S.A.

Gernd von Dewitz

Ingo Riedl MedizinTechnik

Pablo Guzovsky

Tel. +1 610 351-7221 Fax +1 610 351-6827 E-Mail IRiedl@atmosmed.com www.atmosmed.com USA / Canada

Phone +52 55 56060777 Fax +52 55 56060520 E-Mail gvdewitz@dewimed.com.mx www.dewimed.com.mx Mexico

Phone +55 11 32894600 Fax +55 11 32844484 E-Mail pablo@panmedica.com.br www.panmedica.com.br Brazil

Ferrari Medical Ltd.

Representaciones Médicas „Mary“ S.R.Ltda.

Panadex S.A.

Ronaldo Luiz Ferrari

Mary Tafur

Phone +55 11 3205-6200 Fax +55 11 3205-6211 E-Mail ronaldo@ferrarimedical.com.br www.ferrarimedical.com.br Brazil

Phone +51 1 6140600 Fax +51 1 6140603 E-Mail int.supplier@medicasmary.com www.medicasmary.com Peru

Auditron Argentina S.A.

Auditron Chile

Hugo Wainerman Phone +54 11 43739800 Fax +54 11 43736560 E-Mail info@auditron.com.ar www.auditron.com.ar Argentina

72

Panmédica

Daniel Nocetti Phone +56 22366838 Fax +56 22366877 E-Mail danielnocetti@auditron.cl www.auditron.cl Chile

Ariel Panduro P. Phone +51 223 0412 Fax +51 223 0414 E-Mail ariel@panadex.com www.panadex.com Peru


MedizinTechnik

Africa, Middle East

Egyptian Group Co. S.A.E.

MEDICALEX

S.E.H.L.

Mohammed Ben Sadik

Yazzine Azzouz

Ayman Younis Phone +002 0222687712-13 Fax +002 0222687714 E-Mail ayounis@eggroup-eg.com www.eggroup.com.eg Egypt

Phone +213 21690551 Fax +213 21690551 E-Mail azzouz_medicalex@yahoo.fr

Phone +212 522 200356 Fax +212 522 263988 E-Mail mbensadik@gmail.com

Algir

Morocco

TDW Medical (Pty.) Ltd.

General Business Trading

General Medicals W.L.L

Tahar Somai

Terry Wiegand

K. Sridhar

Phone +27 11 7643438 Fax +27 11 7643438 E-Mail terryw@tdwmed.co.za www.tdwmed.co.za South Africa

Phone +216 71704200 Fax +216 20437417 E-Mail tahar.somai@gbtrade.com Tunisia

Phone +973 17 727600-213 Fax +973 17 728274 E-Mail sridhar.medics@intercol.com www.intercol.com Bahrain

X-Ray Iran Co. Ltd.

DANEL Medical Equipment

Hekmamed

Ori Danel

Mehdi Mohseni

Dr. Naser Tiari

Phone +98 21 66957185 Fax +98 21 66417190 E-Mail info@xrayiran.com

Phone +972 3 6326353 Fax +972 3 7600684 E-Mail ori@danelmedical.com

Phone +218 21 3608493 Fax +218 21 3611339 E-Mail hekmamed@hotmail.com

Iran

Israel

Libya

73


MedizinTechnik

Middle East

SAM MEDICAL CORPORATION.

Technomedics Co. LTD

Nizar S. Al-Kubati

Sami Aggad

Sherif Shehata

Phone +967 4 218111 Fax +967 4 218113 E-Mail info@sammedical-ye.com www.sammedical.com.ye Yemen

Phone +962 6 5532395 Fax +962 6 5533294 E-Mail techno@nets.com.jo Jordan

Phone +974 403 9550 Fax +974 403 9551 E-Mail sherif.shehata@aamalmed.com www.ebnsina.com.qa Qatar

Central Circle Co.

Ibn-Sina Pharmacy LLC

Intermed PAL.

Hani Hamad

Ramesh Prakash

Omer Fittiani Phone +965 2 411748 Fax +965 2 411758 E-Mail cencico@qualitynet.net

Phone +968 24822108 Fax +968 24813472 E-Mail ibnsina@omantel.net.om

Phone +972 2 2409616 Fax +972 2 2409790 E-Mail info@intermed-pal.com

Kuwait

Oman

Palestine

Wisam Medical Equipment

Alphamed Co.

Al-Jeel Medical & Trading Co. Ltd.

Abdul Kader Al-Kodsi

Alaa Hamdan Phone +966 1 2168222-236 Fax +966 1 2168566 E-Mail ayasin@aljeel.com www.aljeel.com.sa Saudi Arabia

74

AAMAL MEDICAL CO.

Phone +963 11 2311159 Fax +963 11 2311634 E-Mail wisam-me@scs-net.org Syria

Haitham Mafouz Phone +971 267 30114 Fax +971 267 31224 E-Mail Haitham.T@akigroup.com www.alphamedgroup.com UAE


MedizinTechnik MedizinT echnik

Asia

ATMOS Shanghai Representative Office

Medicorp. Sdn Bhd

Rohit Surgical PVT. LTD.

Rohit Grover

Lily Yan

Priscilla Hue

Phone +91 11 25753575 Fax +91 11 25754575 E-Mail rohitsur@ndf.vsnl.net.in

Brunei

Phone +86 21 64260679 Fax +86 21 64260679 E-Mail SYingYan@atmosmed.de www.atmosmed.com.cn China

MNE TECHNOLOGIES

PT. Surgika Alkesindo

Wako Shoji Co. Ltd.

Phone +673 265 2339 Fax +673 265 2329 E-Mail phue@medicorp.biz

MedizinTechnik

Handy Gunawan

N. Chelvadorai

MedizinTechnik

India

Fumio Osada

Phone +91 80 40545050 Fax +91 80 25590943 E-Mail sales@mneindia.com www.mneindia.com India

Phone +62 21 4253634 Fax +62 21 4253635 E-Mail surgika@cbn.net.id www.surgika.com Indonesia

Phone +81 466 842485 Fax +81 466 842484 E-Mail f.osada@wako-shoji.com www.wako-shoji.com Japan

ATMOS Asia SDN BHD

Europ Continents My.

United BMEC

Christophe Debroise

Matthias Straub Phone +006 03 20727107 Fax +006 03 20728109 E-Mail mstraub@atmosasia.com www.atmosmed.de Malaysia

MedizinTechnik

Phone +95 15 243301 Fax +95 15 05209 E-Mail europcomya@mptmail.net.mm www.europcontinents.com Myanmar/Cambodia/Vietnam/Laos

Vincent Tan Phone +65 63052500 Fax +65 63052549 E-Mail TanVincent@uwhpl.com www.unitedbmec.com Singapore

75


MedizinTechnik MedizinT echnik

Asia

Total Technologies (Pvt) Ltd.

Value-Rx, Inc.

Shoukat Ali Phone +92 42 757-7897 Fax +92 42 753-6586 E-Mail medl@wol.net.pk www.totalgroup.com.pk Pakistan

Endomed (1999) Co. Ltd.

Padon Thuvanalin Phone +66 2731 567-4 Fax +66 2376 0982 E-Mail padon@endomedgroup.com www.endomed.co.th Thailand

76

Mervynsons (PVT) LTD.

Ranil M. Weliwitigoda

Daniel Geiger Phone +63 2 396-5220 Fax +63 2 634-2085 E-Mail danielgeiger@gmail.com

Phone +94 11 2686789 Fax +94 11 2699618 E-Mail mervynsons@asianet.lk

Philippines

Sri Lanka


MedizinTechnik

Australia

Lateral Medical

David Fenech Phone +61 7 31391207 Fax +61 7 30366187 E-Mail david@lateralmedical.com www.lateralmedical.com Australia

77


Medical technology for a better life! ATMOS MedizinTechnik GmbH & Co. has evolved into an exemplary company in the medical technology sector and thus obtained great acceptance. ATMOS stands for: 1. Ongoing growth of ATMOS. We grow at a higher rate than the medical technology market. ATMOS has attained a significant market position in its business units and defined regional markets. We are among the market leaders. 2. ATMOS offers innovative and complete solutions (products and services) which inspire our customers. 3. The success of our company gives us flexibility and the freedom of decision. 4. We are resting solidly on at least 3 „main pillars“ (business units). ENT and Gynaecology workstations digital suction and drainage systems OEM business 5. ATMOS has modern, ideal “business processes”. We have a process oriented organisation. 6. ATMOS has an exemplary „company culture“, the employees enjoy working for ATMOS. Target orientation and transparency of the strategic alignment are important for us. The company and our employees should benefit from our success, this has become reality. 7. The ATMOS trademark is and will remain a strong „brand“ in the field of medical technology, standing for quality and innovation. 8. Competence. Customers, business partners, opinion leaders, salesmen, subsidiaries and agencies enjoy the level of co-operation with ATMOS. They are perfectly trained. 9. ATMOS employees are highly motivated, team-orientated, modern and international thinking, they will go through ‘fire and water’ for their ATMOS. In our region we an esteemed company with good employee opportunities, this also applies to our subsidiaries 10. We are an esteemed enterprise with good employee opportunities, this also applies to all subsidiaries ,Q WKH ¿ HOG RI PHGLFDO WHFKQRORJ\ $7026 LV D JOREDO SOD\HU ZLWK Centres of excellence in Germany and Asia as well as 11 sales companies around the world.

78


ATMOS General terms and conditions MedizinTechnik

1. General:

case. Should the delivery delay be caused by a culpable infringement

also applies in the case of our culpable infringement of substantial

Our General Standard Terms and Conditions apply exclusively. Client’s

of non-substantial contractual duties, our client is also entitled to claim a

contractual duties The indispensable conditions of German Liability Law remain unaffected thereby.

terms and conditions which are contrary to or deviate from our General

one-off damage compen-sation worth 3 percentage points of the delivery

Standard Terms and Conditions are not recognised unless their validity

value of the goods for each week’s delay, up to a maximum which is no

is explicitly confirmed in writing. Our General Standard Terms and

higher than 15 percentage points of the delivery value of the goods

to a period of twelve months.

7. Delivery - Familiarisation

10. Reservation of Ownership

- For second-hand equipment, the period of warranty shall be reduced

Conditions also apply even if we deliver to clients without reservation, in the knowledge of the client’s contrary terms and conditions. Our General Standard Terms and Conditions also apply to all future business with that client. 2. Proposal - Order Confirmation

In the case of the delivery of devices for the medico-technical industry

We retain ownership of our goods until the receipt of all payments

which require assembly and/or familiarisation for the final customer using

arising from the business relationship, including all demands arising

specialist trade personnel (such as Ear, Nose and Throat Apparatus and

from installation orders, subsequent orders, repairs, accessory deliveries

Suction Units), we reserve the right to deliver the goods exclusively to

and replacement orders. Should we have agreed upon payment on the

Our proposals are subject to change without notice unless otherwise

the relevant specialist traders. Should the trader not carry out assembly

basis of cheque and bill transactions, the ownership reservation applies

stated in our order confirmation. Each order is only accepted by us

and/or familiarisation for the final customer, this is carried out by us. In

until the cheque received by us has been paid in, and does not expire

following our written order confirmation. 3. Orders Every order requires an exact description of all of our product’s details. We assume no liability for errors and damage caused by inaccurate or

such cases, we reserve the right to charge the client for the additionally

through our credit upon receiving the client’s cheque. In the case of

created costs. Our specialist traders operate a recording system so

a breach of contract by the client, especially payment arrears, we are

that, if necessary, our products can be traced to the final customer. The

entitled to repossess our goods. Repossession of our goods repre-sents

specialist trader undertakes to immediately report to us all events and

a withdrawal from the contract, unless explicitly declared in writing by

risks which must be reported in connection with our products.

us. We have the right to utilise the product after its repossession, whilst

8. Passage of Risk - Packaging

deducting appropriate utilisation costs.The client is responsible for

incomplete ordering details. 4. Prices

the income form such use is balanced against the client’s arrears, after Unless otherwise stated in our order confirmation, delivery is agreed

handling the goods with care. Should maintenance and inspection work

Unless otherwise stated in the order confirmation, our prices in the

ex factory. The risk of the goods’ damage or loss is therefore transferred

be necessary, the client must carry these out punctually at his own cost.

order confirmation are ex factory prices and exclude packaging and

to the client as soon as the goods leave the factory or the client is in

Our client is entitled to sell the goods he has bought from us in a proper

value added tax. Packaging is charged separately at cost price in the

default of acceptance of the goods. This also applies to cases where we

sale transaction. However, he must immediately assign all outstanding

invoice. Value added tax is charged separately in the invoice according

confirm prepaid carriage. Transport packaging and all other packaging

claims to the value of the final invoice sum (including value added tax)

to the legal rate on the invoice date. We reserve the right to change

according to the packaging regulations is not returnable. Our client is

of our claims to his customers or third parties. The client is entitled to

prices appropriately should price reductions or increases, especially

responsible for disposing the packaging at its own cost. Our deliveries are

collect this claim even after such assignment. Our right to collect the

due to wage settlements, changes in the price of materials or currency

insured by us at the client’s expense unless explicitly otherwise agreed.

claim ourselves remains unaffected thereby.We undertake to release

fluctuations, be incurred. Proof of such changes will be provided for the

No insurance is arranged in the case of goods which are collected by

the securities to which we are entitled if requested to do so by the

client on request.

our clients. In the case of transport damage, claims are only handled if

client should the realisable value of the our securities be more than 10

the client receives confirmation of any damage, reduced weight or loss

percentage points higher than the outstanding claims. We reserve the

by the shipping company before accepting the delivery.

right to choose the securities to be released.

9. Warranty

11. Plans and Illustrations

5. Payment Conditions - Balancing Unless otherwise stated in the order confirmation, our invoices are payable with a 3% discount within 10 days (except for repair and assembly services) or within 21 days from the invoice date net cash;

The client is responsible for examining the delivered goods

We retain ownership of and copyrights to all plans, illustrations,

money receipts is decisive for complying with this term. We are entitled

immediately after receiving them to determine any eventual deficiencies

calculations and other documents which are attached to our proposals.

to charge interest after the due date at a rate 2% above the relevant

or delivery errors, and to report these immediately. Should the client

The client must receive explicit written permission before passing these

basic interest rate of the German Federal Bank. Should the client have

fulfil this examining and reporting responsibility, and should payment

on to third parties. Imitating our legally patented products is forbidden

payment arrears, we are entitled to charge interest on arrears at a rate

conditions be fulfilled, we shall be liable to the client within the scope

and will be prosecuted.

5% above the relevant basic interest rate of the German Federal Bank.

of legal regulations. Our period of warranty shall in all cases be two

Should we be able to prove higher damages due to arrears, we are also

years. Our client can make use of the warranty as follows, so long as

entitled to claim these. The client only has the right to balance invoices

he can provide first buyer proof (in the form of an invoice or delivery

Our central office is the place of performance for all disputes in

against its own claims should such claims be confirmed in a court of

note) and provided that the product still has the original, unchanged

connection with these General Standard Terms and Conditions and

law or recognised by us. The client does not have the right of retention

serial number:

12. Jurisdiction and Place of Performance

the contracts closed with clients under them. This jurisdiction excludes

due to disputed counterclaims.

a. We choose whether to fulfil our guarantee by providing repair

other jurisdiction relating to persons or subject-matter. Furthermore, our

services free of charge - either on the client’s premises or in our factory

client is not entitled to bring charges against us in another court should

6. Delivery Periods

- or replacing the product. We can also provide these guarantee

Fulfilment of our delivery duties requires the punctual and proper

he file counter-charges, carry out counterbalancing or declare retention.

services through an authorised company;

We, however, are entitled to bring charges against our client at their general place of jurisdiction or at another relevant court recognised by

fulfilment of the client’s duties. The right to defense on the grounds of an

b. Should a product be returned to us, the client agrees to send

unfulfilled contract is reserved.Should the client default in accepting the

the product in its original or similar packaging, offering the same

German or foreign law.Unless otherwise stated in the order confirmation,

goods delivery or breach other cooperation duties, we are entitled either

protection as the original packaging, to our address or any address

our central office is the place of performance.

to withdraw from the contract or claim compensation for any increased

notified by us.

costs incurred up to that time without setting a further deadline. The

c. Our guarantee ceases to apply if changes of any kind have been

right to make further claims is reserved. Furthermore, in such cases,

made to our product, unless such changes have been made by us

Lenzkirch, September 2008

the risk of coin-cidental destruction or a coincidental deterioration in

or a company authorised by us, or have been previously agreed

ATMOS MedizinTechnik GmbH & Co. KG

the quality of the delivered goods is transferred to the client in the case

upon in writing by us. Our guarantee also ceases to apply if third

79853 Lenzkirch/Germany

of default in accepting such goods or payment arrears. Acts of God or

parties have carried out repairs to our products or replaced parts

stoppages (due to insufficient supplies of material, industrial disputes

thereof. This applies regardless of the fact whether these measures

etc.) entitle us either to demand an appropriate extension of delivery

individually or collectively led to a deficiency of the product;

periods or to partly or entirely dissolve the delivery contract. This does

d. We accept no responsibility for damage defects caused by

not give the client the right to claim damages. We have fulfilled delivery

- operational wear and tear;

periods if the delivery goods have left our factory or the client has been

- incorrect installation or incorrect or insufficient maintenance;

informed of the goods’ readiness for delivery within such delivery periods.

- incorrect operation of the product (in contradiction to the handbook

Delivery periods stipulated by the client are not recognised by us unless

delivered with the product); - improper use or operating faults; -

they form part of our order confirmation. We adhere to legal terms and

inappropriate or negligent handling and care, especially with respect

conditions in cases where, as a result of an undue delay in the delivery

to dirt, lime, suction of fluids, inappropriate cleaning and sterilisation;

for which we are liable, the client is entitled to claim that his interests

- using accessories and/or replacement parts which are not explicitly

in a continued fulfilment of the contract have ceased. We also adhere

approved;

to legal terms and conditions should a delay in delivery be caused by

- incorrect assembly and/or initial operation by the client or third

deliberate or grossly negligent action by us or our representatives for

parties; - the client’s negligence in handling the product; - unacceptable

which we are responsible. We are also responsible for such actions by

operating conditions, such as humidity, temperatures, the power supply,

our representatives or agents. Should the delivery delay not be caused

vibrations.

by our deliberate infringement of contractual duties for which we are

- accidents, acts of God, especially lightening, water, fire, public

responsible, our liability is limited to damage which is regarded as typical

unrest and insufficient ventilation. We are not liable for damage to

for that case. We are liable according to the legal terms and conditions if

other objects apart from our product itself, except in the case of any

and in so far as the delivery delay for which we are responsible is caused

deliberate or grossly negligent actions by us or our representatives or

by an infringement of a substantial contractual duty. In such cases, our

agents. Should no deliberate breach of contract be claimed, our liability

liability is also limited to damage which is regarded as typical for that

is limited to damage which is regarded as typical for tthat case. This

7KLV FDWDORJXH LV FRS\ULJKWHG 'XSOLFDWLRQ WUDQVODWLRQV PLFURÂżOPLQJ DQG VDYLQJV RQ HOHFWURQLF V\VWHPV SDUWLFXODUO\ IRU FRPPHUFLDOSXUSRVHV are illegal without prior agreement of the manufacturer. All compiled data are based on manufacturers instructions. All logos, product names and designations used in this catalogue are property of the respective manufacturer. :H GR QRW WDNH RYHU DQ\ ZDUUDQW\ DQG OLDELOLW\ LQ WKH FDVH RI PLVVLQJ LQVFULSWLRQV 6XEMHFW WR PRGLÂżFDWLRQV DQG DPHQGPHQWV


MedizinTechnik

www.atmosmed.com Your ATMOS Partner

ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Str. 12, 14-16, 18 79853 Lenzkirch/Germany Phone +49 7653 689-374 Fax +49 7653 68986-374 ApplicationSolutions@atmosmed.de www.atmosmed.com REF

2011-12 Index: 01


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.