2015
PRODUCT CATALOGUE
Autronica Fire and Security AS Petrochemical, Oil & Gas
Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire and gas safety worldwide. Our products ensure safety in applications on land, sea and in the petrochemical, oil and gas sectors. Owned by United Technologies Corporation (UTC), we employ more than 450 people handling the complete value chain, from idea, development and manufacturing to the marketing, sales and servicing of our products. We are an international company with worldwide offices and our HQ is located in Trondheim, Norway’s technology hotspot. Protecting life, environment, and property
2
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Autronica Fire and Security Onshore Global
CONTENTS AutroSafe 4 IFG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Flame detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Panels – AutroSafe 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Panel kits – AutroSafe 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Loop panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Switches and converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 I/O modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 OPC server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Integrated fire and gas (IFG) modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cabinets and racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Mounting accessories for cabinets and racks . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Power supply units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Customer configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Flame detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Cable glands/Blind plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Test equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
AutroMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Software licences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Software modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Software hardcopies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Gas detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Gas detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Toxic gas detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Toxic gas sensor modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Display units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Toxic gas transmitters and termination boxes . . . . . . . . . . . . . . . . . . . . . . . . . 54 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Calibration kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Accessories for calibration kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Other detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Alarmline linear heat detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Aspirating detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Piping ¾’’ (27 mm) – halogen free . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Beam detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Loop units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Input and output units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Manual call points and release stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Alarm units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Door magnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Accessories for loop units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Service tools for detection loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Omicron systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Gas sampling system – OGS 3.1 and OGS 3.11 . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Direct gas sampling system – OGS 2.1 sampling . . . . . . . . . . . . . . . . . . . . . . 68 Water ingress system – OAS WI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Stringent control throughout Autronica Fire and Security AS assures the excellence of our products and services. For a complete overview of our approvals, go to www.autronicafire.com.
Autronica Fire and Security AS Petrochemical, Oil & Gas
3
AUTROSAFE 4 IFG – Ten years with SIL 2 certification
Our task was demanding, yet simple: Take the best fire and gas (F&G) safety system around and make it even better. The new and improved AutroSafe Integrated Fire and Gas (IFG) 4 is designed for the toughest requirements and expands the possibilities of a F&G detection system even further. From offshore platforms to LNG plants to refineries, AutroSafe IFG 4 delivers the most rigorous F&G safety yet. Autronica Fire and Security launched AutroSafe, our high-end fire detection system, in 1999. From day one, AutroSafe has proven its unique stability and reliability in more than 15 000 of installations worldwide, both on- and offshore. AutroSafe IFG 4 provides advanced functionality for a wide range of applications. The system is designed to meet all requirements in the high-end segment of the offshore market. It is certified according to European directives (CPD) requiring EN 54 compliance, and is approved by Factory Mutual (FM) according to NFPA 72. Additionally, the F&G system is approved according to SIL2 requirements by TÜV Nord. Reliable communication is paramount to your safety. That’s why we’re adding AutroNet to the AutroSafe IFG system, an innovative network solution safeguarding communication between panels. AutroNet ensures a redundant and high-speed network, expanding the reach of the AutroSafe IFG system even further. The system can be set up either in a star or ring network, depending on your needs. History proves you can rely on AutroSafe IFG. All existing functionality has stood up to the toughest tests worldwide for more than 10 years. With AutroSafe IFG 4, Autronica has once again taken fire safety to a higher level.
4
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global
Architectural example
HMI: AutroMaster ISEMS
Safety PLC
AutroNet A
Fire & gas control panel AL_Com loop
AutroNet B
Switch
Repeater panel
Information loop panel Standard AutroSafe loop units
PowerLoop
Operator panel
IS isolator unit AutroFlame detector AutroPoint gas detector AutroSafe IS loop units
Controller Repeater panel
AutroPath gas detectors Information loop panel
AutroSafe IFG – a complete solution for fire and gas detection
Autronica Fire and Security AS Petrochemical, Oil & Gas
5
Panels – AutroSafe 4 The AutroSafe 4 family consists of four different panel types. These are: •
Fire alarm control panel, BS-420. BS-420 is the main panel in the AutroSafe family. It can be used as a stand-alone panel as well as part of a network system. All operations, alarm management, indications and other functions within an operation zone are controlled and handled by the panel. The panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special function buttons (e.g. Silence Alarms). Loop driver, input and output modules can be connected. An integrated AutroFieldBus interface makes it possible to connect AutroFieldBus equipment to the panel. All AutroSafe systems must include at least one BS-420 panel.
•
Operator panel, BS-430. As for the BS-420 panel, all operations, alarm management, indications and other functions within an operation zone are controlled and handled by the BS-430 panel. The panel is equipped with a display, light indicators, a numeric keypad, a navigation wheel and special function buttons (e.g. Silence Alarms). No loop driver, input or output modules can be connected to this panel.
•
Controller, BC-420. The BC-420 serves as a connection unit for loop driver modules as well as input and output modules. It is equipped with two light indicators for System Fault and Power. The panel has neither display nor operator buttons. An integrated AutroFieldBus interface makes it possible to connect AutroFieldBus equipment to the panel.
•
Controller rack unit BC-440. Serves as a connection unit for the detection loop, alarm sounders, controls and inputs. It is a variant of the BC-420 prepared for rack installations. Together with the I/O modules the unit will have the full functionality of the BC-420. Equipped with 2 Ethernet ports, one AutroFieldBus port and one serial port.
•
Repeater panel, BU-BV-420. Physical dip-switches on the panel control the BU-BV-420 panel function. As an alarm operation panel it can operate alarms within one or more operation zones. As an information panel no operation of alarms are available. The information panel provides information from one or more operation zones.
In addition to the panels the power cabinet BP-405 is a part of the AutroSafe 4 family. The cabinet includes a 5 A power pack (BPS-405) which provides six 24 VDC / 2 A outputs. The input voltage is 115 / 230 VAC and the total maximum power available is 24 VDC / 5 A. An integrated AutroFieldBus interface makes it possible for the power pack to communicate (send fault messages) with the BS-420 or BC-420 panel. The cabinet provides space for two 12 V / 18 Ah batteries (not included).
6
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global 4 Panel kits – AutroSafe
Panel kits – AutroSafe 4 An Al_Com+ stack can contain up to six loop driver modules (BSD-3xx). By using AutroFieldBus, an additional Al_Com+ stack (with up to six additional loop driver modules) can be added to the system. NOTE! The AutroSafe panels are certified with the Al_Com+ modules mounted inside the panel cabinet.
Image
Part number
Description
116-KIT-BS-420G
Fire alarm control panel kit
116-KIT-BS-420G2
Fire alarm control panel kit approved acc. to IEC 61508 SIL2
116-KIT-BC-420
Controller kit
116-KIT-BC-420G2
Controller kit approved acc. to IEC 61508 SIL2
116-BC-440
Controller rack unit
116-BC-440G2
Controller rack unit approved acc. to IEC 61508 SIL2
116-KIT-BS-430
Operator panel kit
116-KIT-BS-430G2
Operator panel kit approved acc. to IEC 61508 SIL2
116-KIT-BU-BV-420
Repeater panel kit
116-KIT-BU-BV-420G2
Repeater panel kit approved acc. to IEC 61508 SIL2
116-BP-405
Power cabinet
Including
Options
Panel front BSV-420G Cabinet UEA-400 Power supply module BSS-310A Communication module BSL-310 Text foils E-2879/GB-G
Loop driver module BSD-310 Loop driver module H.P. BSD-311 BS-100 loop driver module BSD-330 Output module BSB-310A Output module BSJ-310 Input module BSE-310 Input module BSE-320 Dual power mon. module BSS-311 Dual serial communication ports
Panel front BCV-420 Cabinet UEA-400 Power supply module BSS-310A Communication module BSL-310 Text foils E-2880/GB-G*
Loop driver module BSD-310 Loop driver module H.P. BSD-311 BS-100 loop driver module BSD-330 Output module BSB-310A Output module BSJ-310 Input module BSE-310 Input module BSE-320
–
–
Panel front BSV-420 Cabinet UE-1488 Text foils E-2879/GB-G*
–
Panel front BUV-420 Cabinet UE-1489 Text foils E-2880/GB-G*
–
Cabinet UEA-410 5 A / 24 V power unit BPS-405
Available space for 2 x 12 V / 18 Ah batteries
*: Please specify language GB-G when ordering
Autronica Fire and Security AS Petrochemical, Oil & Gas
7
Loop panels We have now included loop-powered panels in our portfolio, providing our customers a number of advantages: Quicker installation, reduced cabling and cost, and lowered system complexity. A detection loop can accommodate up to eight loop panels.
Image
Part number
Description
Dimensions H x W x D (mm)
Current consumption
Notes
116-KIT-BU-110
Fire brigade loop panel kit*
310 x 154 x 45
<1 mA (idle) 6 mA (max)
Enables silencing the panel’s internal buzzer, silencing alarms, and resetting the system. Alarms only are shown in the display.
116-KIT-BV-110
Information loop panel kit*
310 x 154 x 45
<1 mA (idle) 6 mA (max)
Indication device only. Provides information related to the defined operation zone(s).
* Please specify language when ordering IS = Icelandic GB = English BR = Portuguese E = Spanish F = French PL = Polish H = Hungarian RK = Russian SF = Finnish I = Italian
NL = Dutch DK = Danish S = Swedish N = Norwegian
Switches and converters A network solution (AutroNet) with more than two panels demands the use of switches. Fibre converters are utilized to extend your network where fibre is available. VDSL converters are utilized to make use of existing copper wiring when upgrading old systems. Only the listed Ethernet switches and converters are approved and supported by Autronica Fire and Security AS. The type and number of switches/converters depend on the installation/ network construction (no. of panels and distance between panels and switches/converters).
Image
8
Current consumption (max.) @ 24 VDC
RJ45 ports
Fibre optic ports**
Operating temperature
Part number
Description*
116-5151-030.2127
FL switch SFNT 5TX
120 mA
5
–
-40 - 75°C
116-5151-030.2128
FL switch SFNT 4TX/FX
160 mA
4
1 MM (SC)
-40 - 75°C
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global Loop panels
Switches and converters (cont.)
Image
Current consumption (max.) @ 24 VDC
RJ45 ports
Fibre optic ports**
Operating temperature
Part number
Description*
116-5151-030.2129
FL switch SFNT 8TX
153 mA
8
–
-40 - 75°C
116-5151-030.2130
FL switch SFNT 7TX/FX
175 mA
7
1 MM (SC)
-40 - 70°C
116-5151-030.2131
FL switch LM 5TX
150 mA
5
116-5151-030.2132
FL switch LM 4TX/FX
380 mA
4
1 MM (SC)
-40 - 70°C
116-5151-030.2133
FL switch LM 4TX/2FX
400 mA
4
2 MM (SC)
-40 - 70°C
116-5151-030.2134
FL switch LM 4TX/FX SM
380 mA
4
1 SM (SC)
-40 - 70°C
116-5151-030.2135
FL switch LM 4TX/2FX SM
400 mA
4
2 SM (SC)
-40 - 70°C
* SFNT = Standard Function, Narrow housing, high Temperature range LM = Lean Managed SFNB = Standard Function, Narrow housing, Basic entry level SFN = Standard Function, Narrow housing ** MM = Multi Mode
-40 - 70°C
SM = Single Mode SC = Square Connector (Set and Click, Stab and Click, Standard Connector)
Autronica Fire and Security AS Petrochemical, Oil & Gas
9
Switches and converters (cont.)
Image
Current consumption (max.) @ 24 VDC
RJ45 ports
Fibre optic ports**
Operating temperature
Part number
Description*
116-5151-030.2142
FL switch SFNB 4TX/FX SM 20
185 mA
4
1 SM (SC)
0 - 60°C
116-5151-030.3001
Jetcon 1301-S single mode fibre converter
150 mA
1
1 SM (SC)
-40 - 70°C
116-5151-030.3002
Jetcon 1301-M multi mode fibre converter
150 mA
1
1 MM (SC)
-40 - 70°C
116-5151-030.3003
Jetcon 2502 ethernet/VDSL 2 converter
210 mA
2
–
-40 - 70°C
* SFNT = Standard Function, Narrow housing, high Temperature range LM = Lean Managed SFNB = Standard Function, Narrow housing, Basic entry level SFN = Standard Function, Narrow housing
** MM = Multi Mode SM = Single Mode SC = Square Connector (Set and Click, Stab and Click, Standard Connector)
Printer
Image
–
10
Part number
Description
116-BUP-400
Log printer unit for AutroSafe 4
116-1712-012.0001
Printer paper 57 x 46 x 13 mm / 25 m
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global I/O modules
I/O modules AutroSafe IFG features input and output modules for different applications (monitored alarm loops, servicing relays and LEDs, control inputs, etc.). The modules have the same format, mount onto the panels’ DIN-mounting rail and plug into one another. Important note on module capacity. Each fire alarm panel/controller contains a power supply module BSS-310A and a communication module BSL-310. The BS-420 and BC-420 panels have space for up to 12 modules totally inside the cabinet. An Al_Com+ stack can contain up to six loop driver modules (BSD-3xx) By using AutroFieldBus, an additional Al_Com+ stack (with up to six additional loop driver modules) can be added to the system.
Monitors short circuits •
Loop driver module
–
–
•
•
116-BSD-310/N
Loop driver module
–
–
•
•
116-BSD-311
Loop driver module H.P.
–
–
•
•
Output module
116-BSD-310
Autronica Fire and Security AS Petrochemical, Oil & Gas
Maximum per panel
Total outputs 4
116-BSB-310A
Amplified power output
Total inputs 0
Description
For use in EX zone 2 only
Monitored outputs •
Part number
Monitored inputs
Image
Ensures loop communication
NOTE! The AutroSafe panels are certified with the Al_Com+ modules mounted inside the panel cabinet.
Notes
Requires external 24V
•
•
6/12
Max. 127 loop units
6/12
Max. 127 loop units
6/12
11
12
4
0
Input module
8
0
Galvanically insulated inputs
116-BSJ-310
Output module
0
8
Open transistor outputs
116-BSS-310A
Power supply module
4
0
116-BSS-311
Dual power monitoring module
4
4
116-BSE-310
Input module
116-BSE-320
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
Maximum per panel
Ensures loop communication •
BS-100 loop driver module
Amplified power output
Monitors short circuits •
116-BSD-330
For use in EX zone 2 only
Total outputs –
Description
Monitored outputs
–
Part number
Monitored inputs
Image
Total inputs
I/O modules (cont.)
Notes
8
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global Communication
Communication
Image
Part number
Description
116-BSD-321/1
AutroFieldBus protocol converter Interface between AutroFieldBus and Al_Com+. Enables communication between all Al_Com+ modules in an Al_Com+ stack connected to AutroFieldBus. The module enables AutroSafe DualSafety configuration, with both ordinary Al_Com communication and AutroFieldBus.
116-BSL-310
AutroSafe communication module, serves as an interface for the common internal communication line between all the different I/O modules. Part of the fire alarm control panel.
116-BSL-321
Multi mode fibre optic converter Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre optic modem. The converter ensures reliable communication for distances of up to 3000 m. Uses multi-mode (62.5/125 µm or 50/125 µm) fibre-optic cable. Degree of protection: IP20
116-BSL-322
Single mode fibre optic converter Amplifier for AUTROLON/AutroFieldBus networks, which acts as a fibre-optic modem. The converter ensures reliable communication for distances of up to 15000 m. Uses single-mode (9/125 µm) fibre-optic cable. Degree of protection: IP20
116-BSL-325
AUTROLON/AutroFieldBus communication amplifier Amplifier for communication signals on networks. The amplifier ensures reliable communication in systems where there is great distance between the system panels, and in applications where there are many panels. The amplifier increases maximum cable length from 1000 m to 2800 m. Degree of protection: IP20
116-BSL-336
Voyage data recorder interface Allows AutroSafe fire and gas detection systems data to be logged on voyage data recording systems. Converts standard AutroSafe AutroCom messages to NMEA-0183 standards-compliant strings, allowing events to be written to the VDR. Degree of protection: IP20
116-BSL-337
AutroSafe BU-70 interface module Enables the connection of BU-70/BU-100/BU-101 to AutroSafe. This is a simple, cost effective way to upgrade BS-100 systems to AutroSafe. The RS232/20 mA current loop converter BSL-12/2 must be used to convert RS232 to 20 mA current loop communication. Degree of protection: IP20
Autronica Fire and Security AS Petrochemical, Oil & Gas
13
OPC server
Part number
Description
116-AS-OPC-SERVER/CD1
AutroSafe OPC server CD V1.2 incl. access code for access level 1. Includes read access to all status information for detectors, output and alarm devices. This level of license will also make it possible to send (write) Silence, Reset and SetTime commands to the AutroSafe system. Within this level you can also Disable/Enable detectors.
116-AS-OPC-SERVER/CD2
AutroSafe OPC server CD V1.2 incl. access code for access level 2. Includes all functionality in level 1, plus the possibility to Activate/Deactivate and Enable/Disable outputs and alarm devices via OPC write commands.
116-AS-OPC-SERVER/CD3
AutroSafe OPC server CD V1.2 incl. access code for access level 3. Includes all functionality in level 1 and 2. This level also provides additional information for points, for example AMEAS, Temp, Smoke, Alarm limits and Engineering values.
14
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Global Integrated Onshore fire and gas (IFG) modules
Integrated fire and gas (IFG) modules
Image
Part number
Description
116-BN-342/1
PowerLoop 4-20 mA input unit, rack mounted A general-purpose PowerLoop interface designed for third-party detectors connected to the AutroSafe IFG system. The unit has a 4-20 mA input galvanically isolated from the PowerLoop. 19â&#x20AC;? 3U rack version, bare PCB with 19â&#x20AC;? rack front panel, no DC/DC. Degree of protection: IP20
116-BN-342/2
PowerLoop 4-20 mA input unit, DIN rail mounted A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe IFG system. The unit has a 4-20 mA input galvanically isolated from the PowerLoop. DIN rail version, bare PCB in an open DIN rail box, no DC/DC. Degree of protection: IP20
116-BN-342/EX
PowerLoop 4-20 mA input unit, field mounted A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe IFG system. The unit has a 24 VDC/400 mA supply output providing power to the connected detectors, plus a 4-20 mA input galvanically isolated from the PowerLoop. EEX me version including 9,5 W 24 VDC/DC for external detector power supply. Cable entry, PowerLoop: 2 x M25. Cable entry, 4-20 mA input: 1 x M25 Degree of protection: IP66
116-BSD-340/1
PowerLoop driver module, rack mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Degree of protection: IP20
116-BSD-340/2
PowerLoop driver module, DIN rail mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Degree of protection: IP20
116-BSD-340/EX
PowerLoop driver, for hazardous areas, zone 1 and 2, field mounted The module has a capacity of up to 15 detectors connected directly with protocol interface or through interface unit (BN-342/XX). The number of detectors must be verified by means of a PowerLoop calculator. Up to 31 BSD-340 units can be connected to one alarm panel through the AutroFieldBus driver (EAU-341). Dimensions of entries: 5 x M20, 1 x M25. Degree of protection: IP66
Autronica Fire and Security AS Petrochemical, Oil & Gas
15
Cabinets and racks
Dimensions HxWxD (mm)
Part number
Description
116-UEA-323/1
Cabinet for flush mounting BS-410/-420/BC-420
116-BT-400/1
Termination cabinet for AutroSafe 4
116-BT-401/B
Battery cabinet 2 x 12 V/12 Ah
346 x 195 x 107
116-BT-423/B
Battery cabinet 2 x 12 V/27 Ah
152 x 420 x 142
Notes
320 x 320 x 140
Mounting accessories for cabinets and racks Module height unit = 44.5 mm. Width unless specified otherwise = 48.3 mm. Rittal cabinets or equivalent are available on request.
Dimensions (mm)
Height units
19” subrack, Europe
w = 160
3
116-UW-1454
Mounting kit for 19’’ cabinet/rack. Front panel.
h = 399
9
For BS-420
116-UW-1482
Mounting kit for 19’’ cabinet/rack. Front panel
h = 266
6
For BU-BV-420
116-UW-1514
Mounting plate for flush mounting panel front in 19” cabinet/ rack
h = 399
9
For BS-420/-430 and BC-420
116-UW-1516/1
Dummy plate 19”
h x w = 128 x 60
3
For BC-440
116-UW-1518
Mounting plate
h x w = 622 x 455
–
For mounting AutroSafe 4 front panel on double BS-100 cabinet
116-UE-1662
Spacer (between 2 rack mounted panels)
h x w = 80 x 137.5
–
Part number
Description
116-UB-383
16
Autronica Fire and Security AS Petrochemical, Oil & Gas
Notes
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global Batteries
Batteries Autronica Fire and Security AS offers accumulator batteries for every Autronica fire alarm system. Generally, 24 VDC back-up is used, this requires two batteries per panel. All batteries are sealed and can be placed in cabinets.
Voltage
Dimensions LxWxH
Part number
Description
Weight
116-4160-001.
FIAMM FG20721
12 V / 7.2 Ah
2,4 kg
79 x 56 x 106 mm
116-4160-002.
FIAMM FG21803
12 V / 18 Ah
5,9 kg
181 x 76 x 167 mm
116-4160-003.
FIAMM FG22703
12 V / 27 Ah
8,7 kg
166 x 175 x 125 mm
116-4160-004.
FIAMM FG24204
12 V / 42 Ah
13,8 kg
196 x 163 x 174 mm
116-4160-005.0001
FIAMM FG21202
12 V / 12 Ah
4,0 kg
151 x 98 x 99 mm
116-4160-005.0003
FIAMM FG20341
12 V / 3 Ah
1,41 kg
134 x 67 x 60 mm
116-4160-006.
FIAMM FG27004
12 V / 70 Ah
22,7 kg
350 x 166 x 174 mm
116-4160-006.0001
Sonnenschein A512/115
12 V / 115 Ah
40,0 kg
286 x 269 x 230 mm
116-4160-006.0003
Sonnenschein A512/85
12 V / 80 Ah
31,0 kg
330 x 171 x 236 mm
116-4160-006.0004
Sonnenschein A115/200
12 V / 200 Ah
70,0 kg
518 x 274 x 242 mm
Power supply units
Part number
Description
Output voltage
116-BPS-405/BOXED
Power supply unit for AutroSafe 4
24 VDC / 5 A
116-BPS-410/BOXED
Power supply unit for AutroSafe 4
24 VDC / 10 A
116-BPS-410/115/BOXED
Power supply unit for AutroSafe 4, 115 VAC
24 VDC / 10 A
116-BSS-103A
Power supply for AutroSafe 3, including cover
27,3 VDC / 3 A
116-BSS-103A/02
Power supply, without cover, with NTC resistor. Temperature compensated battery charging
27,3 VDC / 3 A
116-4550-012.2410
Power supply for AutroSafe, for additional power. Temperature compensated battery charging
27,3 VDC / 10 A
116-4660-016.0001
DC/DC converter MINI-PS 12-24 DC / 24 DC1
116-4660-055.0001
DC/DC converter
24 VDC / 1 A 24 VDC / 6,3 A
Autronica Fire and Security AS Petrochemical, Oil & Gas
17
Cables
Part number
Description
116-XJA-027
Connection cable for AS 2000; for connection between PC and fire alarm panel (AS窶全YSUTILPAC includes this item)
116-XJA-033
Connection cable for EAU-321, for PC module interconnection
116-XGE-1/10-XX
Ribbon cable. Optional lengths: 40 or 110 cm. Replace XX with length
116-XL-073
Conversion cable from AutroSafe 3 to AutroSafe 4
Relays
Part number
Description
116-7624-030.0001
Relay PLC RSC 24 DC/21, single change-over contact
116-7624-030.0002
Relay PLC RSC 24 DC/21-21, double change-over contact
Customer configuration
Part number
Description
116-PROG-AUTROSAFE
Customer specific software for AutroSafe
116-TXT-AUTROSAFE
Customer texts/controls
18
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroSafe 4 IFG Autronica Fire and Security Onshore Global Cables
Autronica Fire and Security AS Petrochemical, Oil & Gas
19
AUTROMASTER â&#x20AC;&#x201C; a fully integrated safety and emergency management system
The AutroMaster is an integrated safety and emergency management system combining the strengths of a powerful fire detection system with control and monitoring functions dedicated to make sure you are in control in case of an emergency. Graphical user interface The AutroMaster provides an intuitive control and monitoring interface built to save valuable time when every second counts. Status information is displayed in real-time with easy-to-understand graphical representation. Navigation is fast and instinctual and the powerful zoom functions allow you to monitor all areas in great detail. AutroMaster displays values for smoke density and heat in dynamic colours, making it easy to perform the necessary actions during emergencies. Interoperability Control and monitoring of third party systems can easily be performed via serial protocols or network interfaces. They provide connection to basically any source â&#x20AC;&#x201C; network time servers, telephone systems for text messaging, public address systems for automated voice messaging, emergency lights, access control systems, CCTV, automation systems and so on. Logging and reporting The AutroMaster keeps track of all events in the system and has a built-in report generator. This provides a cost-effective system log for maintenance and documentation purposes. Decision-making tools In high-risk environments around the world, a seemingly innocuous fire can quickly escalate into an emergency of large proportions. When disaster strikes and you only have seconds to make the proper decisions, the right safety and emergency management system is an invaluable asset. The AutroMaster includes a Decision Support System (DSS) that will help you make the right decisions at the right time.
Easy to use, provides full overview and saves valuable time
20
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroMaster Autronica Fire and Security Onshore Global Cables
AutroMaster editions AutroMaster ISEMS is the complete AutroMaster edition, including all functionality. In addition, we offer a market specific edition with the modules most relevant for the oil and gas market
AutroMaster POG edition
AutroMaster ISEMS
Fire management basic functions
•
•
MultiSensor control
•
•
Report generator
•
•
Control and monitoring of emergency lights/LLL
•
•
AutroSafe IFG unit support
•
•
Touch screen support
•
•
Modules/functions Basic functionality
Extended functionality
Decision support system/incident manager
•
Electronic plotting table
•
Training/simulation module
•
Event record and replay module
•
Video module (live video support CCTV)
•
•
Remote connect function
•
Message centre module
•
Interfaces Hernis CCTV interface
•
System-S interface
•
NMEA interface
•
Saia PLC support
•
VDR output
•
Siemens S7 PLC support
•
MODBUS interface
•
ESPA 4.4.4 interface
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
21
Software licences
Part number
Description
116-PROG-AUTROMASTER-POG
AutroMaster Oil & Gas Edition – For the Petrochemical, Oil and Gas market applications, support for the SIL2 approved AutroSafe IFG panel is mandatory. The AutroMaster Oil & Gas Edition is specially designed to use the AutroSafe IFG functionality to among other functions provide gas trending and LEL indication.
116-PROG-AUTROMASTERISEMS
AutroMaster ISEMS – Provides the full range of functionality – every possible add-on module is included in this package, making it the perfect choice for demanding applications and professional customers.
116-PROG-AM-UPGRADE
Upgrade of AutroMaster to most recent version – Existing AutroMaster customers can upgrade their license to the most recent version of AutroMaster. Requires change of AutroMaster configuration data.
Software modules
Part number
Description
116-PROG-AM-MOD-DSS
Decision Support System (DSS) – An interactive incident management system for AutroMaster. The DSS gives operators access to customer-specified checklists. The checklists are organized as checkpoints with one or more action items that can be used to manage operations, and these can be marked off as actions are completed.
116-PROG-AM-MOD-EPTABLE
Electronic fire control plotting table – gives you a dynamic plotting table to keep track of actors events during an emergency or drill. All EPT activity is logged in the Decision Support System and is available for later reviews.
116-PROG-AM-MOD-TSIM
Training/Simulation module – A tool to simulate pre-configured events. During a simulation it is possible to pause, stop/end, and continue the simulation. Running the simulation tool is similar to running a live event, alarms and faults are acknowledgeable and resettable. Every event is logged, and after a simulation (or a stop), a full log can created and it is possible to replay the simulation using the Event record/replay module.
116-PROG-AM-MOD-EVENT
Event Record/Replay module – Offers a screenshot-based replay of incidents on AutroMaster and can be configured to start recording manually or on pre-configured events as pre-warning, alarm or simulation. Recordings are available for replay, and under replay the operator can start, stop, pause, fast-forward and fast backwards. It is possible to export stored events.
116-PROG-AM-MOD-VIDEO
Video interface module – Includes display of live video in AutroMaster from IP based video cameras.
116-PROG-AM-MOD-REMOTE
Remote Connect function – The Remote Connect Module enables a remote connection to AutroMaster from any location using a server/client technology.
116-PROG-AM-MOD-MC
Message Centre module – In the Message Centre the user can send text messages to telephone systems and other AutroMaster PCs. The user can also send pre-recorded voice messages to PA systems. Requires ESPA 4.4.4. interface.
22
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 AutroMaster Autronica Fire and Security Onshoremodules Global Interface
Interface modules
Part number
Description
116-PROG-AM-MOD-HERNIS
Hernis CCTV interface – Interface enables use of AutroMaster together with video cameras and servers from Hernis.
116-PROG-AM-MOD-NMEA
NMEA interface – A protocol used for interface in between maritime electronic equipment, and AutroMaster has built-in support for this in the NMEA interface module. Interface towards GPS is the most common application.
116-PROG-AM-MOD-SAIAPLC
Saia PLC support – With the Saia PLC support, the AutroMaster can interface towards PLCs using Saia as protocol.
116-PROG-AM-MOD-VDROUTPUT
VDR output – Used in maritime applications for giving output to the Voyage Data Recorder. Configuration of which data and status messages to send to the VDR is done by project engineering.
116-PROG-AM-MOD-S7PLC
Siemens S7 PLC support – With the Siemens S7 PLC support, the AutroMaster can interface towards PLCs using S7 as protocol.
116-PROG-AM-MOD-MODBUS
MODBUS interface – With the MODBUS interface AutroMaster can be connected to almost any kind of electronic equipment for monitoring and control.
116-PROG-AM-MOD-ESPA444
ESPA 4.4.4 interface – Offers a serial protocol intended for the interconnection of paging equipment with telephone exchanges or computer systems. The protocol used is message-based and is built upon the ISO1745 transport specification. Required if Message Centre module is used.
Software hardcopies
Part number
Description
116-AUTROMASTER-POG-CD
AutroMaster POG back-up CD without licence
116-AUTROMASTERISEMS-CD
AutroMaster ISEMS back-up CD without licence
Engineering
Part number
Description
116-PROSJAMD
Adding of detectors to drawings
116-PROSJAMDF
Adding of color fill for analog values
Autronica Fire and Security AS Petrochemical, Oil & Gas
23
Hardware
Part number
Description
116-AUTROMASTER-PC-11
PC , desktop version, convertible minitower. Model subject to change without prior notice.
116-AUTROMASTER-RACKPC
19" rack mounted PC
116-5151-020.0210
Industrial PC w/SSD
116-5151-020.1951
19" standard LCD monitor (1280 x 1024 resolution)
116-5151-020.2405
24" widescreen LCD monitor (1920 x 1200 resolution)
116-5151-200.0023
20â&#x20AC;? monitor, console mounted, JH20T17 MMD
116-5151-017.0002
Keyboard - UK/English character set
116-5151-020.0400
Mouse - USB - 3 buttons
116-5760-050.2003
Laser printer, colour, network and USB
116-5151-020.0732
Network card TG-3468 10/100/1000
116-5151-020.0800
3Com switch 5 sp 10/100 109379
116-5151-020.2029
Moxa 4-port serial PCIE
24
Autronica Fire and Security AS Petrochemical, Oil & Gas
LOOP UNITS – a wide range covering your basic fire detection needs
We provide a wide range of loop units for our fire detection systems. Our detectors, manual call points, I/O units, control units and alarm units are developed and approved according to European directives (CPD) requiring EN 54 compliance and other appropriate worldwide regulations. The loop units are available both with and without SelfVerify function. SelfVerify solves all issues of manual maintenance, leaving time consuming and costly physical testing no longer necessary. With AutroSafe SelfVerify®, the system checks all detectors, interfaces, connections and cables – from detector chamber to alarm output – every single day. Not only does the system test whether a detector is capable of provoking an alarm, it even verifies the sensitivity of every detector with a calibrated signal. The SelfVerify system ensures that each detector always responds to the correct alarm level. In the event of irregularities, the display on the operating panel will accurately pinpoint the source of any problem. SelfVerify ensures that you have the safest and most reliable fire safety system available – a system ensuring optimal detection.
SelfVerify ensures optimal detection
26
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global Input and output units
Input and output units
116-BN-180
AutroKeeper
•
Degree of protection*
For use in EX areas
SelfVerify
Requires external PSU
Inputs/outputs
Description
Monitored output
Part number
Monitored input
Image
Configurable input
AutroSafe offers a wide range of input and output units for many different applications. The system features Exn-, Exia- and Exd approved input and output units for high risk applications. All input and output units feature automatic addressing and short-circuit protection.
IP30
Notes
Use two units to access one loop from two loop controllers. DIN rail mounting in cabinet.
•
•
IP54 IP67
116-BN-201
Monitoring unit
116-BN-221/01
Extinguishing control unit
116-BN-221/02
Output unit with 7 A relay
116-BN-300
Input unit
•
•
1/0
•
116-BN-300M
Modular input unit
•
•
1/0
•
•
1/0
For external units
•
2/1
•
IP67
•
0/1
•
IP67
Loop controlled FAD unit
IP54 IP67
For interfacing external units, clean contacts, alarm relays, etc.
Mounting on TS-35 rail
*: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be ordered (see page 43) Autronica Fire and Security AS Petrochemical, Oil & Gas
27
116-BN-304
116-BN-305
Input/output unit
Dual monitored input/ output unit
116-BN-307
Monitored Fire Alarm Device Control Unit
116-BN-310
Relay output unit
116-BN-320
Interface unit
•
•
•
•
•
•
1/0
•
•
•
•
•
•
1/1
•
2/2
•
Degree of protection*
For use in EX areas
SelfVerify
Requires external PSU
116-BN-303
Single monitored input unit
Inputs/outputs
Description
Monitored output
Part number
Monitored input
Image
Configurable input
Input and output units (cont.)
IP54 IP67
IP54 IP67
IP54 IP67
•
IP54 IP67
0/1
•
IP54 IP67
2/1
•
IP54 IP67
0/1
•
Notes
Function selectable via dip switch Limited approvals (Not SIL2/FM/USCG)
Function selectable via dip switch Limited approvals (Not SIL2/FM/USCG)
Function selectable via dip switch Limited approvals (Not SIL2/ FM/USCG)
Limited approvals (Not SIL2/ FM/USCG)
*: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be ordered (see page 43)
28
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global Input and output units
Degree of protection*
For use in EX areas
SelfVerify
Requires external PSU
Inputs/outputs
Monitored output
Monitored input
Image
Configurable input
Input and output units (cont.)
Part number
Description
116-BN-320/2
Door control unit
•
2/1
•
IP54 IP67
116-BN-320/4
Standard control unit
•
2/1
•
IP54 IP67
116-BN-320/5
Sprinkler monitoring unit
•
1/0
•
IP54 IP67
116-BNB-330A
Loop adapter unit for conventional loops
•
1/1
•
•
IP20
Replacement unit for BNB330 in existing AutroSafe 3 systems
116-BNB-331
Loop adapter unit for conventional loops
•
1/1
•
•
IP20
AutroSafe ver. 4.4.1
116-BN-500/EX
Input unit
•
1/0
IP54 IP67
For interfacing external units, clean contacts, alarm relays, etc. Zones 0, 1 & 2
•
•
•
Notes
Control of external equipment
*: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be ordered (see page 43)
Autronica Fire and Security AS Petrochemical, Oil & Gas
29
SelfVerify
For use in EX areas
Degree of protection*
Monitored input
116-BN-500/N
Input unit
•
•
1/0
•
•
IP54 IP67
For interfacing external units, clean contacts, alarm relays, etc. Zone 2
116-BN-505/EXD
Input unit with BNB300
•
•
1/0
•
•
IP66
Zones 1 & 2 only
Inputs/outputs
Description
Monitored output
Part number
Configurable input
Image
Requires external PSU
Input and output units (cont.)
Notes
*: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be ordered (see page 43)
30
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Control Global units
Control units
Disablement unit
2
116-BW-201/XX
Disablement unit
0
116-BW-202/XX
Daytime/Nighttime unit
2
116-BW-203/XX
Daytime/Nighttime unit
0
116-BU-200
Alarm controller unit
2
•
•
•
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
Degree of protection
116-BW-200/XX
For AutroSafe only
Description
Configurable delay
Part number
For external control
Image
Number of buttons
AutroSafe offers control units for enabling and disabling of detectors, as well as daytime/nighttime units. Available in several language versions. Replace XX with country code.
Notes
IP66
Available in Swedish, English and Russian
•
IP66
Available in Swedish and English
•
IP66
Up to two units can be powered from detector loop. To connect more units, external 24 VDC power is required. Available in English only.
•
IP66
Up to two units can be powered from detector loop. To connect more units, external 24 VDC power is required. Available in English only.
•
IP66
31
Detectors AutroSafe offers a wide range of detectors for many different applications, with or without SelfVerify. The following series are available: •
200 series, standard interactive addressable detectors
•
300 series with SelfVerify, interactive addressable detectors
•
500 series with SelfVerify, interactive addressable detectors for use in hazardous areas
•
•
•
•
•
•
IP56
116-BD-501/N
•
•
•
•
•
•
IP56
116-BD-55/XXXEXD
•
•
•
116-BD-55/XXXEXDN
•
•
•
116-BD-505/140EXD
•
•
•
•
•
IP66
60 ºC, non-configurable class, explosion proof
116-BD-505/160EXD
•
•
•
•
•
IP66
70 ºC, non-configurable class, explosion proof
116-BD-505/190EXD
•
•
•
•
•
IP66
90 ºC, non-configurable class, explosion proof
116-BD-501/EX
• •
•
•
Degree of protection IP56
SIL 2 certified •
Sealed unit •
High sensitivity
•
For use in EX zone 2 only
•
•
For use in EX areas
Environmentally protected
•
116-BD-501
SelfVerify
•
•
MultiSensor
•
116-BD-200M
Smoke
•
Part number
Heat
Image
Including base
The system also offers Exn- and Exia approved versions of detectors designed for use in high risk applications. S series smoke detectors are specially designed for applications where high sensitivity is required.
IP56
Notes For galleys/cold areas (-30 ºC)
IP66/67
* Conventional
IP66/67
** Conventional
*: Available with the following alarm temperatures (replace XXX with °F): 140 °F (60 °C), 160 °F (70 °C), 190 °F (90 °C), 225 °F (110 °C), 325 °F (165 °C), 360 °F (180 °C), and 450 °F (230 °C) **: Available with the following alarm temperatures (replace XXX with °F): 225 °F (110 °C), 275 °F (135 °C), 325 °F (165 °C), 360 °F (180 °C), and 450 °F (230 °C)
32
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015
•
116-BDH-500
•
•
•
116-BDH-500/EX
•
•
•
116-BDH-500/N
•
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
•
IP44D
•
•
IP44D
•
•
IP44D
•
IP44D
•
IP44D
•
IP44D
•
IP44D
Sealed unit
•
High sensitivity
For use in EX zone 2 only
Degree of protection
•
SIL 2 certified
116-BDH-300
For use in EX areas
Environmentally protected
Including base
SelfVerify
MultiSensor
Part number
Smoke
Image
Heat
Loop Autronica Fireunits and Security Onshore Global Detectors
• •
116-BHH-300
•
•
116-BHH-500
•
•
•
116-BHH-500/EX
•
•
•
116-BHH-500/N
•
•
•
116-BHH-500/S
•
•
•
116-BHH-500/S/EX
•
•
•
116-BHH-500/S/N
•
•
•
116-BHH-320
•
•
116-BHH-520
•
•
•
116-BHH-520/EX
•
•
•
116-BHH-520/N
•
•
•
116-5815-021.0001
•
•
116-5861-033.0150
•
•
• •
• •
• •
•
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
•
Notes
IP54
Thermostat ATHF-SE-2, 20-150°C For use in Safe Area or Ex zone 2 Suitable for use in sauna
IP65
SWM-1KL 140°C
33
Manual call points and release stations AutroSafe offers a wide range of manual call points for different applications, every unit features SelfVerify. Two main series are available: • •
300 series with SelfVerify, interactive addressable manual call points. 500 series with SelfVerify, interactive addressable manual call points for use in special environments.
Manual call point
116-BF-500/N
Manual call point
116-BF-501
Manual call point
116-BF-501/EX
Manual call point
116-BF-501/N
Manual call point
*: Degree of protection, inner housing
34
Autronica Fire and Security AS Petrochemical, Oil & Gas
•
Degree of protection*
116-BF-500V2/EX
•
Duty label, ref. E-2327
Manual call point
Glass NOT included
116-BF-510WP-H
Metal connection box
Manual call point
LED indicator
116-BF-300V2
Extreme environments
Description
Watertight / outdoor model
Part number
For use in EX zone 2 only
Image
For use in EX areas
The system features Exn- and Exia approved versions for high risk applications. All our manual call points can be delivered with a double-action cover.
•
IP42D*
•
IP52*
•
IP44D*
•
•
•
•
IP44D*
•
•
IP66
•
•
IP66
•
•
IP66
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Global Manual callOnshore points and release stations
Manual call point
116-BF-503/0100
Manual call point
116-BF-503/EX/0100
Manual call point
116-BF-503/N/0100
Manual call point
116-BF-503/EX/0200
CO2 release station
116-BF-503/N/0200
CO2 release station
116-KIT-BF-503/EX/0300
Release station
116-KIT-BF-503/N/0300
Release station
116-KIT-BF-503/EX/0400
Release station
116-KIT-BF-503/N/0400
Release station
116-BF-503/0500
Release station
116-KIT-BF-503/EX/0500
Release station
116-KIT-BF-503/N/0500
Release station
116-BFG-3/XX
*XX replacements: No ending = No text D = German GB = English GB/AR = English and Arabic
•
•
•
•
•
•
•
•
•
•
•
•
•
IP66
•
•
IP66
•
•
N/A
IP66
•
•
N/A
IP66
•
•
N/A
IP66
•
•
N/A
IP66
•
•
N/A
IP66
•
•
N/A
•
IP66
•
•
N/A
•
IP66
•
•
N/A
•
IP66
•
•
N/A
•
IP66
•
•
N/A
•
•
N/A
•
IP66
•
•
N/A
•
IP66
Degree of protection
116-BF-502/N
•
IP66
Duty label, ref. E-2327
Manual call point
•
Glass not included
116-BF-502/EX
•
Metal connection box
Manual call point
LED indicator
116-BF-502
Extreme environments
Description
Watertight / outdoor model
Part number
For use in EX zone 2 only
Image
For use in EX areas
Manual call points and release stations (cont.)
IP66
Glass for call point, available in several languages. Replace XX with country code*.
GB/D = English and German GB/P = English and Portuguese H = Hungarian N/GB = Norwegian and English P = Portuguese
Autronica Fire and Security AS Petrochemical, Oil & Gas
RC/GB = Chinese and English SF = Finnish SU = Russian
35
MEDC manual call points and release stations
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request. These products are produced according to customer specifications.
36
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global Alarm units
Alarm units
116-BBR-7M
Alarm bell 6”
•
116-BBR-130
Combined detector base and addressable sounder.
•
116-BBR-230
Sounder
•
•
•
•
•
•
•
Degree of protection
•
Light output (c/j)*
Beacon
Sound output (dBA/1 m)
116-BBL-100/IP
Light
•
Sound
Beacon
Watertight
116-BBL-100
Configurable
Description
Signal presets
Part number
Electronic
Alarm output mounted
Image
Loop mounted/addressable
AutroSafe offers a wide range of alarm units for connection to detection loops or dedicated alarm outputs.
•
-
2c
IP32C
Supported only by AutroSafe version 4.3 or later
•
-
2c
IP66
Supported only by AutroSafe version 4.3 or later
93
–
IP55
90
–
IP32C
Supported only by AutroSafe version 4.3 or later
100
–
IP32C
Supported only by AutroSafe version 4.3 or later
Notes
*: Candela (c), Joule (j) **: If loop driver BSD-311 is used, max. no. of units per loop is 40 If loop driver BSD-310 is used, max. no. of units per loop is 21
Autronica Fire and Security AS Petrochemical, Oil & Gas
37
90
2c
IP21C
Supported only by AutroSafe version 4.3 or later
•
•
100
2c
IP32C
Supported only by AutroSafe version 4.3 or later
•
•
100
2c
IP65
Supported only by AutroSafe version 4.3 or later
•
–
–
IP30
10112
–
IP54
Base sounder w/ beacon
•
•
•
116-BBQ-230
Sounder/beacon
•
•
116-BBQ-230/IP
Sounder/beacon
•
•
116-BU-47
Conventional alarm indicator
•
116-7770-009.0002
Roshni LP, shallow base
Autronica Fire and Security AS Petrochemical, Oil & Gas
•
Degree of protection
•
116-BBQ-130
•
Light output (c/j)*
IP65
•
•
Sound output (dBA/1 m)
–
•
•
Light
Watertight
Sound
100
Sounder
•
•
Notes
Supported only by AutroSafe version 4.3 or later
116-BBR-230/IP
*: Candela (c), Joule (j)
38
Configurable
Signal presets
Description
Electronic
Part number
Alarm output mounted
Image
Loop mounted/addressable
Alarm units (cont.)
•
•
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global Alarm units
Sound output (dBA/1 m)
Light output (c/j)*
Degree of protection
–
IP65
•
•
101
0,7 j
IP54
•
•
101
0,7 j
IP65
110
–
IP66 /67
–
5j
Roshni LP, shallow base
•
•
•
•
•
116-7770-009.0005
Roshni, deep base
•
•
•
•
•
116-7780-004.0001
Flashni, shallow base
•
•
•
116-7780-004.0002
Flashni, deep base
•
•
•
Configurable
116-7770-009.0004
Light
102
Sound
Watertight
IP54
Signal presets
–
Description
Electronic
102
Part number
Alarm output mounted
Image
Loop mounted/addressable
Alarm units (cont.)
Notes
48 VDC 116-7782-001.0003
Sounder
•
116-4340-006.0201
Xenon beacon
•
•
•
ATEX approval Ex II 2GD EExd IIC T5
*: Candela (c), Joule (j)
Autronica Fire and Security AS Petrochemical, Oil & Gas
39
Light
Sound output (dBA/1 m)
Light output (c/j)*
Degree of protection
•
•
•
–
2,5 c
IP54
116-4340-006.0925
Solex beacon, deep base
•
•
•
–
2,5 c
IP65
116-4340-006.0926
Solex beacon, shallow base
•
•
–
2,5 c
IP54
116-4340-007.0001
Solista LX beacon, wall mounted , deep base
•
•
•
•
–
W2.47.5
IP65
Red flash
116-4340-007.0002
Solista LX beacon, ceiling mounted, shallow base
•
•
•
•
•
–
C-37.5
IP33C
Red flash
116-4340-007.0005
Symphoni LX WP conventional base beacon, wall mounted
•
•
•
•
•
–
W2.47.5
IP66
Red flash
•
*: Candela (c), Joule (j)
40
Autronica Fire and Security AS Petrochemical, Oil & Gas
Sound
Solex beacon, shallow base
Watertight
Electronic
116-4340-006.0924
Configurable
Description
Signal presets
Part number
Alarm output mounted
Image
Loop mounted/addressable
Alarm units (cont.)
•
•
•
Notes
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global Alarm units
Configurable
Light
Sound output (dBA/1 m)
•
•
•
•
•
–
C-37.5
IP33C
Red flash
116-4340-007.0008
Symphony G1 LX, wall
•
•
•
•
•
–
W2.47.5
IP21C
Red flash
116-4340-007.0009
Symphony G1 LX, wall
•
•
•
•
•
–
W2.47.5
IP21C
Red flash
Degree of protection
Signal presets
Solista LX wall, shallow base
Light output (c/j)*
Electronic
116-4340-007.0007
Sound
Description
Watertight
Part number
Alarm output mounted
Image
Loop mounted/addressable
Alarm units (cont.)
Notes
*: Candela (c), Joule (j)
MEDC beacons, sounders, and combination units
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request. These products are produced according to customer specifications.
Autronica Fire and Security AS Petrochemical, Oil & Gas
41
Door magnet
Image
Part number
Description
116-6731-017.0002
Door magnet armature. Type AG w/adjustable socket. For use with part no: 116-6731-017.0005
116-6731-017.0005
Door holding magnet. GPT, holdpower 650 N, 1 W, 40 mA. Manual release push button. DNV approved. For use with part no: 116-6731-017.0002
Accessories for loop units
Suitable for EX installations
Part number
Description
116-BWA-100
Base for interactive detector heads, mandatory
116-BWB-110
Base adapter for analogue addressable detectors mounted on interactive loops
116-BWP-100/20
Drip proof conduit box with M20 glands
•
116-BWP-100/25
Drip proof conduit box with holes for M25 glands
•
116-BWP-143A
Ventilation duct adapter, for interactive systems
•
116-BJ-358/100
Pipe kit, L=100 mm
•
116-BJ-358/150
Pipe kit, L=150 mm
•
116-BJ-358/300
Pipe kit, L=300 mm
•
116-BJ-358/550
Pipe kit, L=550 mm
•
116-BJ-358/800
Pipe kit, L=800 mm
•
116-BJ-358/1000
Pipe kit, L=1000 mm
•
116-BWP-145
Heated detector base
116-8142-983.5115
Transformer 230/48 V for up to 10 BWP-45/BWP-145
116-WBW-100
Bypass unit for BWA-100
•
116-WBW-101
Mounting plate for false ceilings
•
116-BZ-500
Galvanic barrier for Exia approved detectors, for field mounting
116-BZ-500/01
Galvanic barrier for Exia approved detectors, for cabinet mounting
116-4860-011.0100
Polycarbonate cover for manual call point BF-300V2
116-4890-021.0001
Lift flap in polycarbonate for manual call point 116-BF-502, all versions
•
116-4890-021.0010
Lift flap in stainless steel for manual call point 116-BF-502, all versions
•
116-4890-022.0001
Lift flap in polycarbonate for manual call point 116-BF-501, all versions
•
116-4890-022.0010
Lift flap in stainless steel for manual call point 116-BF-501, all versions
•
42
Autronica Fire and Security AS Petrochemical, Oil & Gas
•
PRODUCTS 2015 PRODUCTS 2015 Loop Autronica Fireunits and Security Onshore Global loops Service tools for detection
Accessories for loop units (cont.)
Suitable for EX installations
Part number
Description
116-6571-011.1920
Cable gland M20-1.5 for degree of protection IP67 for I/O units. NB! Order with 116-6531-006.1920
116-6531-006.1920
Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008
Power base 230 V for Roshni alarm unit
Service tools for detection loops
Suitable for EX installations
Part number
Description
116-WAS-2000
AS2000, loop diagnostic tool
116-WBJ-5/01
Test gas dispenser for smoke detectors, excluding pole
•
116-WBJ-5/02
Telescopic pole, 1,26 m to 4,5 m, 1,8 kg
•
116-WBJ-5/03
Expansion pole, 1,13 m. 0,5 kg
•
116-WBJ-5/04
Test gas for smoke detectors
•
116-WBJ-6/01
Heat detector test kit, battery operated, 2 x batteries and charger included (for WBJ-5/02)
116-WBJ-10
Testifire smoke/heat detector test kit (head unit 2 x battery baton and fast charger)
116-WBJ-10/01
Testifire smoke/heat head unit
116-WBJ-10/02
Smoke capsule for WBJ-10 (6 pack)
116-WBJ-10/03
Solo 760 battery baton
116-WBJ-10/04
Solo 725 universal fast battery charger
116-WBJ-140
Installation/extraction tool for AutroSafe detectors
Autronica Fire and Security AS Petrochemical, Oil & Gas
•
43
FLAME DETECTION – keeping a close watch
Autronica’s flame detectors are solutions for applications in which risk to personnel is high and where fire might result in a large loss of equipment. Beyond critical life-safety concerns, our products have proven to minimize total cost of ownership while minimizing false alarms. Our industrial and commercial applications include oil and gas pipelines, turbine enclosures, offshore platforms, and Floating Production Storage and Offloading (FPSO) vessels. Bottom line – no other company offers more flame-detection technologies with wider area coverage, higher false-alarm immunity, reduced response times, and the appropriate global approvals. And to improve ease of use, all X-Series flame detectors have HART-protocol options.
Protecting life, environment and property by any means necessary
44
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Flame detection Autronica Fire and Security Onshore Global Flame detectors
Flame detectors
SIL 2 approved
With HART protocol
Cert. -55 °C to +125 °C for T4
For PowerLoop
Combination unit with camera av.
Addressable (built-in BNB-300)
Aluminium housing
Image
Stainless steel housing
All flame detectors have 4 x M25 cable entries, unless otherwise specified. Swivel mount, glands and blind plugs are not included. All detectors have an ambient temperature range of -55°C to + 60°C for T6 and -55°C to + 75°C for T5, unless otherwise specified. Degree of protection all detectors and cameras: IP66
Part number
Description
116-5861-011.4310
AutroFlame X33AF multisp. IR
•
•
116-5861-011.4316
AutroFlame X33AF multisp. IR
•
•
116-5861-011.4320
AutroFlame X33AF multisp. IR
•
•
116-5861-011.4322
AutroFlame X33AF multisp. IR
•
•
High sense
116-5861-011.4323
AutroFlame X33AF multisp. IR
•
•
Low sense
116-5861-011.4340
AutroFlame X33AF multisp. IR
•
116-5861-011.4341
AutroFlame X33AF multisp. IR
•
116-5861-011.4360
AutroFlame X33AF multisp. IR
•
116-5861-011.4361
AutroFlame X33AF multisp. IR
•
116-5861-011.4371
AutroFlame X33AF multisp. IR
•
116-5861-011.4373
AutroFlame X33AF multisp. IR
116-5861-011.4381
AutroFlame X33AF multisp. IR
116-5861-011.4383
AutroFlame X33AF multisp. IR
116-5861-011.4384
AutroFlame X33AF multisp. IR
116-5861-011.4385
AutroFlame X33AF multisp. IR
116-5861-011.4391
AutroFlame X33AF multisp. IR
116-5861-011.4392
AutroFlame X33AF multisp. IR
•
•
116-5861-011.4393
AutroFlame X33AF multisp. IR
•
•
116-5861-011.4410
AutroFlame X33AF PL multisp. IR
•
•
116-5861-011.4411
AutroFlame X33AF PL multisp. IR
•
•
116-5861-011.4420
AutroFlame X33AF PL multisp. IR
•
•
116-5861-011.4421
AutroFlame X33AF PL multisp. IR
•
•
116-5861-011.4440
AutroFlame X33AF PL multisp. IR
116-5861-011.4460
AutroFlame X33AF PL multisp. IR
Low sense
• •
• •
• •
•
• •
• • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
Notes
•
UL Brazil approved 3/4” NPT •
3/4” NPT
Low sense
•
•
•
•
45
•
116-5861-011.3980
AutroFlame X98 single IR
•
116-5861-011.3981
AutroFlame X98 single IR
•
116-009585-001
xWatch surveillance camera
•
116-009587-001
xWatch surveillance camera
Autronica Fire and Security AS Petrochemical, Oil & Gas
Notes Hydrogen flame detection
•
•
SIL 2 approved
AutroFlame X32AF multisp. IR
With HART protocol
116-009011-002
Cert. -55 °C to +125 °C for T4
AutroFlame X32AF multisp. IR
For PowerLoop
116-009009-002
Combination unit with camera av.
Description
Addressable (built-in BNB-300)
Part number
*: Other lenses available.
46
Aluminium housing
Image
Stainless steel housing
Flame detectors (cont.)
Hydrogen flame detection
•
•
For use with any flame detector above. M20 PAL video output. For use in EX areas FM/ CSA approved 768 x 484 px 90° optical lens*
PRODUCTS 2015 PRODUCTS 2015 Flame detection Autronica Fire and Security Globalplugs CableOnshore glands/Blind
Cable glands/Blind plugs
Part number
Description
116-6332-032.1925
Blind plug M25, polyamid, Eexe, degree of protection: IP67
116-6530-030.0020
SPMH/NP/M20 blind plug nickle plated brass
116-6530-030.0025
SPMH/NP/M25 blind plug nickle plated brass
116-6571-016.2520
Cable gland adapter M20/M25
116-6571-018.2025
EEXDE adapter M25-20 nickle plated brass
116-6571-070.2025
Cable gland A2LBFM25NP, Brass - nickel plated, Exd/Exe, Degree of protection: IP66/68
116-6571-071.2500
Cable gland M25, polyamid, Eexe, degree of protection: IP67
116-6571-080.0001
501/453/UNIV/B M25 nickle plated brass
116-6571-080.0002
501/421/B M25 EEXE nickle plated brass
116-6571-080.0004
501/453/UNIV/OS-M20 nickle plated brass
116-6571-080.0005
501/453/UNIV/O-M20 nickle plated brass
116-6571-080.0006
501/453/UNIV/A-M20 nickle plated brass
116-6571-080.0007
501/421/Os M20 EEXE nickle plated brass
116-6571-080.0008
501/421/O M20 EEXE nickle plated brass
116-6571-080.0009
501/421/A M20 EEXE nickle plated brass
Accessories
Part number
Description
116-001680-001
K1003A1006 Window cleaner for flame detectors (6 pcs.)
116-004404-002
Q9001H8001 swivel for xWatch camera SS
116-002099-003
Q9001B1175 swivel for xWatch camera alu.
116-5861-011.9050
Q9033B Swivel mount for AutroFlame detectors, stainless steel
116-5861-011.9051
Q9033A Swivel mount for AutroFlame detectors, aluminium
116-007338-010
Q2033A10R 10 degree field-of-view limiter
116-007338-020
Q2033A20R 20 degree field-of-view limiter
116-007338-030
Q2033A30R 30 degree field-of-view limiter/Weather shield (maintains standard field-of-view)
116-007240-001
Q1116A air shield assembly
116-009199-001
Q1198A dual air shield/flange mount assembly
Autronica Fire and Security AS Petrochemical, Oil & Gas
47
Test equipment
Part number
Description
116-006439-004
W8067S Long range test lamp IR/UVIR, (non-EX)
116-004000-006
W867C Portable test lamp 220 V, UV, UV/IR & Single IR
116-007255-001
Q1201C Laser holder for AutroFlame X33AF, UV/IR and UV flame detectors
116-006097-001
Laser aimer (non-EX) for AutroFlame detectors incl. battery
116-009997-001
Charger and battery, for test lamp 116-004000-006
116-007819-001
W6300B Inspector connector for connection to PC utilizing an integral RS485 to RS232 converter for communication
116-009207-001
Inspector monitor software. To be used together with inspector connector
116-009208-001
O/I replacement kit for AutroFlame X33AF with black reflector plate*
116-010831-001
O/I replacement kit for AutroFlame X33AF with stainless steel reflector plate*
116-009208-002
O/I replacement kit for AutroFlame X22, X52 and X98
116-102740-002
Test magnet for AutroFlame X33AF
116-007739-001
Test magnet and extension pole
*Please note: AutroFlame X33AF models are supplied with either a black or a stainless steel reflector plate. These plates are not interchangeable. Order the replacement that matches the reflector plate on your AutroFlame X33AF detector.
48
Autronica Fire and Security AS Petrochemical, Oil & Gas
GAS DETECTION – when every second counts
When it comes to detecting toxic gas would you rather be alerted in 30 seconds... or 5 seconds? In the demanding environments of the petrochemical oil and gas industry, fire and gas detection has to deliver optimal results at all times. Autronica offers traditional detectors with 4-20 mA and/or relay output, but we have also taken the IR point gas detection a step further. By introducing the two wire intelligent communication on our IFG PowerLoop we allow for centralized control of all diagnostic data. Analogue readings and detector self testing features are available from our AutroPoint IR gas detectors. The open path IR gas sensing technology surpasses other alternatives, both with respect to the life cycle cost as well as operational tangibles of a more technical nature. Our AutroPath HC600 open path infrared beam system delivers reliable, combustible gas monitoring for all types of applications. The FlexSonic Acoustic Gas Leak Detector hears gas leaks that others don’t – the instant they occur. It is the first non-contact gas leak detector of its kind that recognizes unique sound “fingerprints,” analyzing 24 discrete ultrasonic bands, while ignoring nuisance ultrasonic sources. A high-fidelity microphone continuously monitors for the distinct ultrasound emitted by pressurized gas leaks across the widest spectrum of frequencies. With our AutroTox toxic gas detector family, you get a gas detector that continuously monitors the atmosphere for potentially hazardous gas leaks and oxygen depletion. An array of sensor models detect a variety of gases in various concentration ranges. Autronica delivers the performance, quality, and reliability you can depend on to keep you safe and satisfied.
50
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 GasFire detection Autronica and Security Onshore Global Gas detectors
Gas detectors
HART protocol included
Cable entries
•
2 x M25
•
2 x M25
•
2 x 3/4" NPT
•
•
2 x M25
•
•
2 x M25
With relay output
With hydrophobic filter*
SIL 2 approved
Acoustic
Image
Infrared hydrocarbon
All gas detectors are delivered with stainless steel housing.
Part number
Description
116-5861-011.5100
AutroPoint HC200
•
116-5861-011.5101
AutroPoint HC200
•
116-5861-011.5102
AutroPoint HC200
•
116-5861-011.5200
AutroPoint HC200
•
116-5861-011.5201
AutroPoint HC200
•
116-010195-232
AutroPoint HC200
•
•
116-010195-233
AutroPoint HC200
•
•
116-010195-234
AutroPoint HC200
•
•
•
116-010195-235
AutroPoint HC200
•
•
•
116-5861-011.5300
AutroPoint HC300PL
•
116-5861-011.5301
AutroPoint HC300PL
•
116-GD10-P00-17DG0XH-00
GD-10P
•
116-5861-011.6100
AutroPath HC600
•
116-Z-02104N4011
Searchline Excel IR gas detector
•
116-Z-02104NXSSA
Searchline Excel IP gas detector
•
116-012152-001
FlexSonic AC100/ ATX kit
•
•
•
3/4” NPT
116-012153-001
FlexSonic AC100/ ATX kit
•
•
•
M25
•
•
Notes
Cepel approved
2 x M25 •
2 x M25 2 x M25
•
2 x M25 2 x M25
Addressable, PowerLoop version
2 x M25
Addressable, PowerLoop version
•
2xM20
1 sec. response
•
2 x M25
•
With SNX universal transmitter
•
*: Recommended for areas with high levels of airborne particulates or humidity. Other detectors available on request.
Autronica Fire and Security AS Petrochemical, Oil & Gas
51
Toxic gas detectors
116-5861-011.6603
AutroTox GTD w/AutroVu AV10 display unit
•
Eex d certified
•
RS485 output
AutroTox GTD w/AutroVu AV10 display unit
With relay output
116-5861-011.6601
Aluminium housing
Description
Stainless steel housing
Part number
NTMOS
Image
Electrochemical
Autronica provides toxic gas detectors for a wide range of gases. These detectors must be combined with a toxic gas sensor module, listed below. The detectors each have a 4-20 mA output and four open ports. HART protocol is included.
•
•
•
•
•
•
•
•
Toxic gas sensor modules
Image
Part number
Description
Range
116-009471-001
GTS H2S 20P
0 – 20 ppm
116-009471-002
GTS H2S 50P
0 – 50 ppm
116-009471-003
GTS H2S 100P
0 – 100 ppm
116-009471-004
GTS Cl2 10P
0 – 10 ppm
116-009471-006
GTS NH3 500P
0 – 500 ppm
116-009471-008
GTS H2 1000P
0 – 1000 ppm
116-009471-009
GTS O2 25V
0 – 25 % by volume
116-009471-010
GTS CO 100P
0 – 100 ppm
116-009471-011
GTS CO 500P
0 – 500 ppm
116-009471-013
GTS SO2 20P
0 – 20 ppm
116-009471-014
GTS SO2 100P
0 – 100 ppm
116-009471-503
GTS H2S 100PTD, DNV approved
0 – 100 ppm
116-009471-509
GTS O2 25VTD, DNV approved
0 – 25 % by volume
116-009471-510
GTS CO 100PWD, DNV approved
0 – 100 ppm
116-009471-511
GTS CO 500PWD, DNV approved
0 – 500 ppm
INMETRO approved versions available
52
Autronica Fire and Security AS Petrochemical, Oil & Gas
Notes
PRODUCTS 2015 PRODUCTS 2015 GasFire detection Autronica and Security Onshore Global Display units
Display units
AutroVu AV10
•
116-011780-081
AutroVu AV10
•
116-011780-082
AutroVu AV10
•
116-5861-011.6401
AutroVu AV10
•
116-5861-011.6403
AutroVu AV10
•
116-011780-003
AutroVu AV10 CGS
•
116-011780-004
AutroVu AV10 CGS
•
Cable entries
116-011780-002
SIL 2 approval
•
Eex d
AutroVu AV10
Relay output
116-011780-001
RS485 output
Description
Aluminium housing
Part number
Stainless steel housing
Catalytic combustible
NTMOS
Image
Electrochemical
All display units have 4-20 mA output and HART protocol included
•
•
•
•
•
5xM25
•
•
•
•
5xM25
•
•
•
•
3/4 NPT
INMETRO (Brazil)
•
•
•
•
3/4 NPT
INMETRO (Brazil)
•
•
•
5xM25
•
•
•
5xM25
•
•
•
5xM25
•
•
•
5xM25
• • • • •
Autronica Fire and Security AS Petrochemical, Oil & Gas
• •
Notes
53
54
Description
Eex d certified
116-009480-004
GTX Transmitter
•
•
•
116-226365-603
STB Termination Box
•
•
•
116-009910-004
NTM1B10W NTMOS H2S Sensor (0-100 ppm)
•
•
•
116-009958-002
GDTB Termination Box
•
•
•
Autronica Fire and Security AS Petrochemical, Oil & Gas
NTMOS
Part number
Electrochemical
Image
Stainless steel housing
Toxic gas transmitters and termination boxes
Notes
For GT3000, M25, SS, 5 ports
PRODUCTS 2015 PRODUCTS 2015 GasFire detection Autronica and Security Onshore Global Accessories
Accessories
Part number
Description
116-007525-003
Direct duct mount kit for point gas detectors AutroPoint HC200 and HC300PL
116-012513-001
Q912 Duct mount M25 with 1 ft. inlet
116-012513-003
Q912 Duct mount M25 with 3 ft. inlet
116-012513-006
Q912 Duct mount M25 with 3 ft. inlet
116-012513-010
Q912 Duct mount M25 with 10 ft. inlet
116-012513-013
Q912 Duct mount M25 with 13 ft. inlet
116-007902-002
System test film 1.1-1.5 LFL - Low alarm
116-007902-003
System test film 1.9-2.5 LFL - High alarm
116-008987-001
Aperture kit for HC600, SS, for distances of 5 to 30 meters
116-009296-001
Aperture kit for HC600, plastic, for distances of 5 to 30 meters
116-009104-001
Alignment telescope for AutroPath HC600
116-226365-111
Toxic sensor termination box and separation kit. JBOX, SEP, AL, M20 CENELEC toxic
116-226365-127
Toxic sensor termination box and separation kit. JBOX, SEP, AL, M25 CENELEC Infinity
116-US-843
Rain and sun shield for point gas detectors AutroPoint HC200 and HC300PL
116-Z-475HP1EKL9GMT
Emerson 475 HART communicator. Instrument for calibration of AutroPoint HC200 and AutroPath HC600 gas detectors. Certified intrinsically safe by CENELEC/ATEX, FM, CSA, FISCO and IECEx
116-Z-GD10-ADAPT1
Duct adapter for point gas detector GD-10P
116-Z-499815712
Sunshade, GD10/PGD10PE
116-Z-ES-244
Gas detector test point
For cable glands and blind plugs, see flame detector section, page 47.
Autronica Fire and Security AS Petrochemical, Oil & Gas
55
Calibration kits
Part number
Gas type
Concentration
Notes
116-006468-001
Methane CH4
50 % LEL
AutroPoint HC200/-300
116-007098-005
Hydrogen Sulphide H2S
50 ppm
12 x ampoules, NTMOS detectors
116-010274-001
Hydrogen Sulphide H2S
10 ppm
GT3000 series
116-010274-002
Hydrogen Sulphide H2S
25 ppm
GT3000 series
116-010274-004
Chlorine Cl2
5 ppm
GT3000 series
116-010274-005
Ammonia NH3
50 ppm
GT3000 series
116-010274-006
Ammonia NH3
250 ppm
GT3000 series
116-010274-008
Hydrogen H2
500 ppm
GT3000 series
116-010274-009
Oxygen O2
20,90 %
GT3000 series
116-010274-010
Carbon Monoxide CO
50 ppm
GT3000 series
116-010274-011
Carbon Monoxide CO
250 ppm
GT3000 series
116-010274-013
Sulfur Dioxide SO2
10 ppm
GT3000 series
116-010274-014
Sulfur Dioxide SO2
50 ppm
GT3000 series
116-225130-005
Hydrogen H2
50 % LEL
AutroPoint H2
116-225130-009
Without gas
â&#x20AC;&#x201C;
AutroPoint H2
Accessories for calibration kits
Part number
Description
116-004976-001
Calibration cup for catalytic detectors, stainless steel
116-005964-001
Calibration cup for point gas detectors AutroPoint H2S, O2 and TX50
116-006672-002
Windshield calibration bag for AutroPoint HC200/-300
116-225741-001
Extra ampoules for 116-007098-005 NTMOS Calibration Kit H2S Ampoule, 50 ppm
116-227117-001
GT3000 replacement cylinder H2S 50 ppm
116-227117-006
GT3000 replacement cylinder O2 20,90%
116-227117-012
GT3000 replacement cylinder H2S 25 ppm
116-227117-018
GT3000 replacement cylinder H2 500 ppm
116-Z-00670
Step regulator with 0,5 L constant flow
116-Z-00671
Step regulator with 1 L constant flow
116-Z-00678
Carrying case for 2 bottles
116-Z-1200674
2.5 LPM constant flow regulator
116-Z-1711020
Test gas, 65 % LEL methane in N2. 110 L
116-Z-1501020
Test gas, 50 ppm H2S. 110 L
116-Z-1404010
Test gas, 50 % LEL H2. 110 L
116-Z-499810874.8
Sample Flow Housing for point gas detector GD-10P
116-Z-03150
Viton hose pr. meter
116-Z-1200673
Reg. valve 0.3-3.0 L/min
Other concentrations and test gases available on request.
56
Autronica Fire and Security AS Petrochemical, Oil & Gas
OTHER DETECTORS – completing the fire detection system
Alarmline linear heat detection (LHD) is a cable-based system providing economical temperature monitoring at the precise point of risk. The system is reliable, flexible and has the ability to detect abnormal temperature variances before fire breaks out. The comprehensive LHD product portfolio allows a vast range of commercial and industrial fire and overheat risks to be protected, in ambient temperatures of 68°C to 174°C. Other options/alarm temperatures available on request. Aspirating detectors function by sampling air via a network of pipes, sampled air is passed through a dust filter and into a detector chamber where the air is analyzed for traces of smoke. Typical applications include laboratories, large open spaces, corrosive environments, archives/ historical buildings and industrial areas. Every detector is “trainable” for the specific environment in which it is installed. Common to all AutroSense detectors is that they are capable of detecting the small amounts of smoke that are generated in the initial phases of a smouldering fire, ensuring the earliest possible warning of a potential fire. At the same time, AutroSense detectors distinguish real smoke from dust and pollutants, reducing unwanted alarms to a minimum. AutroSense 200, AutroSense Micra 25 and Micra 100 are stand-alone aspirating detectors, that can also be connected to fire alarm systems. These units feature built-in intelligence that ensures optimal detection capability. Beam detectors are used in large open areas instead of a quantity of point smoke detectors. The detector protects a given area by sending signals (infrared light beam) between a transmitter and receiver, and detect dimmer or changes in frequency by heat or smoke. Beam detectors are suited to applications in open spaces where costs associated with point smoke detectors would be prohibitive.
58
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Other detectors Autronica Fire and Security Onshore Global Alarmline linear heat detectors
Alarmline linear heat detectors
Image
Part number
Description
116-5843-005.0001
Alarmline analogue cable, K82017
116-5843-005.0003
Alarmline analogue cable, bronze, K82078
116-5843-006.0006
Control unit for analogue cables, LWM-1
116-5843-005.3100
Alarmline digital cable, 68 ยบC nominal, H8040
116-5843-005.3200
Alarmline digital cable, 68 ยบC nominal, H8040N
116-5843-005.2101
Alarmline digital cable, 85 ยบC nominal, H8045
116-5843-005.0101
Alarmline digital cable, 105 ยบC nominal, H8028
116-5843-005.1101
Alarmline digital cable, 174 ยบC nominal, H8069
Recommended interface unit for Alarmline linear heat detectors is BN-303 (see page 28)
Accessories
Part number
Description
116-5843-005.9002
Alarmline L-bracket
116-5843-005.9003
Alarmline edge clip
116-5843-005.9004
Alarmline T-clip
116-5843-005.9005
Alarmline pipe clip
116-5843-006.0010
Termination kit K82023
116-5843-007.0001
EEXE Junction box tank roof
116-5843-007.0002
Automatic cable reel
116-5843-007.0003
Neoprene sleeve B6782-08
116-5843-007.0004
Cable ties B6782-121
Autronica Fire and Security AS Petrochemical, Oil & Gas
59
Part number
Description
Max. sampling holes
Alarm levels
Relays
Image
Sampling pipe inlets
Aspirating detectors
116-5861-018.2000
AutroSense 200
0,0015–25%
200 m
2000 m²
500 m²
4
100
4
5
116-5861-018.1007
AutroSense Micra 25
0,0015–25%
25 m
450 m²
450 m²
1
10
1
2
116-5861-018.1107
AutroSense Micra 100
0,0015–25%
100 m
1600 m²
500 m²
2
50
1
2
Sensitivity (obsc./m)
Max. length piping
Max. coverage Max. BS6266 coverage (Hot Wire (FG) Test)
Recommended interface unit for AutroSense 200 is BN-305 (see page 28) Recommended interface unit for AutroSense Micra is BN-303 (see page 28)
60
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Other detectors Autronica Fire and Security Onshore Global Accessories
Accessories
Part number
Description
116-5861-018.2110
AutroSense command module w/o PSU
116-5861-018.4110
AutroSense Micra relay card w/inputs
116-5861-018.9027
AutroSense 200 dust filter
116-5861-018.9028
AutroSense Micra 25 and 100 dust filter
116-5861-018.3051
Wire burn unit
116-5861-018.9999
Cable for “hot wire” test (roll @ 100 m)
116-BW-75/04
Condensation bottle
116-BW-75/06
Filter
116-BWP-144
AutroSense, detector housing for sampling pipes with detector base BWA-100
116-BWP-44
AutroSense, detector housing for sampling pipes with detector base BWA-40A/1
116-E-2446/1
Label for “DET. POINT”
116-E-2446/2
Label for sampling pipe “Warning”
Piping ¾’’ (27 mm) – halogen free
Image
–
Part number
Description
116-5862-001.0025
Water hose in coil, 25 mm PE50 NT10. Please specify desired length: 50 or 300 meters
116-5861-910.0027
Straight pipe L = 3 m, red, CM10900
116-5861-962.0001
Normal bend 45°, red, CM10905
Autronica Fire and Security AS Petrochemical, Oil & Gas
61
Piping ¾’’ (27 mm) – halogen free (cont.)
Image
62
Part number
Description
116-5861-912.0027
Normal bend 90°, red, CM10906
116-5861-914.1027
Joining socket, red, CM10908
116-5861-964.0001
T-piece, red, CM10909
116-5861-964.0002
End cap, red, CM10927
116-5861-964.0006
Pipe clip, red, CM10954
116-5861-915.1027
Socket union, red, CM10915
116-5861-935.0002
Solvent cement 250 ml w/brush, CM10950
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Other detectors Autronica Fire and Security Onshore Global Accessories
Piping ¾’’ (27 mm) – halogen free (cont.)
Image
Part number
Description
116-5861-922.0010
Sampling hole warning label, CM10960
116-5861-910.0078
10 mm nylon tube, red, 21888-K078
116-5861-922.0007
10mm capillary sampling point, 21888-K068
116-5861-965.0001
Adapter ¾” - 25 mm, red, CM10946
116-5861-965.0002
Adapter ¾” - 25 mm, red, CM10931
116-5861-964.0008
25 mm female / ¾” male adapter, red, CM10952
116-5861-018.9021
Capillary sampling point kit flush, 21888-K074
Autronica Fire and Security AS Petrochemical, Oil & Gas
63
Beam detectors
Image
Part number
Description
Detection distance
Degree of protection
116-5861-021.1001
AutroBeam 100, transmitter (Tx)
5 – 150 m
IP40
116-5861-021.2001
AutroBeam 100, receiver (Rx)
5 – 150 m
IP40
116-5861-023.5101
FireRay 5000-101 Auto aligning infrared optical beam smoke detector. Transmitter/receiver in the same housing, plus reflector.
5 – 50 m
IP54
116-5861-023.5102
FireRay 5000-102 Auto aligning infrared optical beam smoke detector. Transmitter/receiver in the same housing, plus reflector.
50 – 100 m
IP54
116-5861-023.3000
FireRay 3000-101 End to end infrared optical beam smoke detector system. Transmitter, receiver and compact lowlevel controller.
5 – 120 m
IP54
Notes
Will be released in 2015
The AutroBeam 100 is delivered with interface unit BN-40A. Recommended interface units for FireRay detectors are BN-303 or BN-305 (see page 28)
Accessories
Part number
Description
116-5861-021.3002
Calibration tool for AutroBeam 100
116-5861-021.3003
SAC alarm simulator for AutroBeam 100
116-5861-023.5002
FireRay 5000-002: 50 m detector – detector head and 1 x reflector
116-5861-023.5039
FireRay 5000-03: 100 m detector – detector head and 4 x reflector
116-5861-023.5003
FireRay 5000-003: System controller
116-5861-023.5005
FireRay 5000-005: Universal bracket for use with FireRay 5000 detector head or reflector mounting plate (FireRay 5000007/5000-008)
116-5861-023.5006
FireRay 5000-006: Surface mounting plate for 1 or 4 reflectors
116-5861-023.5007
FireRay 5000-007: Mounting plate for 4 reflectors for use with bracket FireRay 5000-005
116-5861-023.5008
FireRay 5000-008: Mounting plate for 1 reflector for use with bracket FireRay 5000-005
116-5861-023.5004
50-100 m kit for FireRay 5000, included in FireRay 5000-102
116-5861-023.1018
Protection cage for FireRay 5000
116-5861-023.3001
FireRay 3000-015: Pair of detectors (transmitter and receiver) for use with FireRay 3000 system
116-5861-023.3002
FireRay 3000-201: Adjustment bracket for use with FireRay detectors
64
Autronica Fire and Security AS Petrochemical, Oil & Gas
OMICRON SYSTEMS – solutions you can trust
The Omicron systems by Autronica include high level/overfill alarm systems, gas detection systems, tank and vapour pressure systems, temperature alarms and calibration equipment. Since delivery of the first generation independent high level system in 1989, we have developed a range of high-tech systems for the shipping and offshore industry. More than 5000 vessels are using system equipment. The systems are designed to attract minimum maintenance overheads. We deliver reliable, service-friendly systems to meet owners’ and regulatory requirements. The systems fulfil IMO, IACS, EC, USCG and classification societies’ regulations. The Omicron systems are based largely on tailor made solutions for FPSOs. Therefore, we give you a short description of the complete systems rather than a description on part number level. Please contact us for more information.
Premium quality safety monitoring and environmental surveillance
66
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Omicron Autronica Fire systems and Security Onshore Global Gas sampling system – OGS 3.1 and OGS 3.11
Gas sampling system – OGS 3.1 and OGS 3.11
For total solutions in gas sampling Omicron gas sampling system OGS 3.1 is our advanced model for special requirements. Different models and options cover most applications you will find in the market today. All delivered parts are completely assembled ready for interconnection to on-site application. OGS 3.1 is based on a scanning method, which means that sample points are being connected to sensor(s) in a cyclic sequence. The operator panel has an LCD display and individual LED lamps indicating each measuring point status. To minimize scanning cycle time and guarantee fresh samples at all times, the system has two vacuum pumps. One main pump, continuously sucking from all sample points and a smaller sample pump taking samples from the actual point according to the sequence. This insures quick response if gas is detected. Purging of sample line is done immediately after each sampling is finished.
New design of the well known OGS 3.1 gas sampling system (smaller and more compact). Gas sampling systems can be used in all spaces where gas detection is requested, and they can handle several gasses simultaneously. Our systems have the unique automatic ”blow-back feature”, which together with two sampling pumps create a rapid and clean sampling cycle. Hence, for gas tankers we are able to handle more points and still maintain the 30 minute rule of IMO Gas Code.
Standard features: • Infrared hydrocarbon sensor with range 0 - 100 % L.E.L
Optional features: • Up to 5 additional units with control transfer function.
•
Low and high gas alarms
•
Multiple operating panels
•
Flame arrestor and shut-off valve for each sampling tube
•
•
Automatic and sequential purging of each sampling tube
Remote alarm unit. Simple alarm status panel with LEDs and buzzer (e.g. for Bridge)
•
Manual disconnection of sampling points not in use (e.g. when water in ballast tanks)
•
Aux. relay outputs. Up to 32 relay outputs, freely configurable to any sample point
•
Two vacuum pumps (main and sample)
•
Standby pump with manual switch over
Non-return valves mounted on deck for ballast tanks in order to avoid liquid entering into the system
•
Dual purge supply (E.g. nitrogen and instrument air)
•
Multi-gas detection. Up to 3 different gas sensors can be installed
Extensive hardware and software system monitoring
•
Alarm printer
•
Bulkhead penetrations
•
Automatic disconnection of sample line when sample point is manually disconnected from scanning cycle
•
RS 485/422 MODBUS RTU serial line output to external computer
•
Custom made systems on request
• •
Autronica Fire and Security AS Petrochemical, Oil & Gas
67
Direct gas sampling system – OGS 2.1 sampling Gas detection in harsh areas such as shale shaker rooms etc. Omicron direct gas sampling system OGS 2.1 sampling is specially made for “direct detection” of harsh areas. Principle The direct gas sampling system consists of two cabinets; one detector cabinet approved for mounting in a Zone 1 area, and one electronic cabinet with power supply, barrier units and alarm panel typically mounted in the cargo control room (CCR). The dual sampling lines cover the same “sampling location”. A built-in purging feature, cleaning the lines sequentially with overlapping detection (line 1 & 2), provides continuous and reliable detection at the monitored area.
Ventilation pipe
Gas alarm
Flow fault
Vacuum pump
High pressure air
Tube/pipe flushing
68
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Omicron Autronica Fire systems and Security Onshore Global Water ingress system – OAS WI
Water ingress system – OAS WI For high level and overfill The Omicron water ingress system has been specially designed and manufactured for detecting the presence of water in the inner bottom in any holds reaching a height of 0,5 m and another height of not less than 15 % of the depth of hold but not more than 2 m. Furthermore, also holds located partially or totally forward of the foremost cargo hold, and ballast tanks located forward of the foremost cargo hold, collision bulkhead of Bulk carrier, in conformity with SOLAS regulation XII/ 12 rule requirement The system consists of a main alarm panel with cabinet and level sensor operated by detecting the conductivity in a liquid when present. The sensor and the alarm panel are connected together with an intrinsically safe barrier. When the presence of water has reached the detecting points (ref. rule requirement) of level sensor installed at the preset level in the cargo hold or other space, the electric signals which are activated on the level switches are transmitted to the main alarm panel. At the same time, the audible and visual alarms are activated on the main alarm panel. The system has also all necessary functions like loop monitoring of sensors and power failure. An overriding device ensures that the alarm can be deactivated or reactivated for the detector installed in the tank and holds used for carriage of water ballast according to the SOLAS regulation XIII 12.1. The main power and standby power are prepared in such way that if the main power fails, the standby power will provide continuous power to the alarm panel, and an alarm will be given.
The sensor: Type WI-22 designed for various locations onboard a bulk carrier. The construction is unique with the following advantages: • Complete unit in stainless steel. •
Non movable parts due to “conductivity principle”.
•
Classified as “simple apparatus”
•
IP68/ 2.5 bar with 35 m signal cable and mounting bracket included.
•
Tested working temperature -25 to 120 °C.
•
Easy to function test.
•
Designed without any active electronic components on deck.
•
Can operate in all sorts of bulk cargoes.
The alarm cabinet: Type OAS is a complete signal monitoring and alarm unit which is delivered for three alarm sensors per cargo hold. The third channel (free of charge ) can be used for alarm sensor on top of the cargo for covering water penetration through hatch covers. • Intrinsically safe connections to sensors. •
Potential free contacts for common external alarms and light & horn.
•
All normal alarm functions.
•
Optional RS485/-422 serial line communication with host computer.
•
The Alarm Panel can either be mounted in the front door of the alarm cabinet or in a common console.
•
Power supply: 115/230 VAC, Emergency power supply 24 VDC
Autronica Fire and Security AS Petrochemical, Oil & Gas
69
CONTACT INFORMATION HEAD OFFICE STAVANGER, NORWAY
UNITED KINGDOM
MIDDLE EAST/SAUDI ARABIA
Autronica Fire and Security AS
Autroncia Fire and Security AS
UTC Fire Safety Middle East
Div. Oil & Gas
Div. Oil & Gas UK
Office 202, Palladium Bldg
Lagerveien 24
c/o Chubb Fire & Security
(Next to KIA car showroom)
NO-4033 Stavanger
UTC Building & Industrial Systems
Sheik Zayed Road
Norway
Littleton Road
PO Box 30791
Phone: +47 90 90 55 00
Ashford
Al Barsha 1, Dubai
Middlesex
The United Arab Emirates
TW15 1TZ
Phone: +971 0 491 99000
England Phone: +44 (0) 1753 825 800 Mobile: +44 (0) 7796 26 26 92
EUROPE & RUSSIA
THE AMERICAS & WEST AFRICA
SOUTH KOREA
Autronica Fire and Security AS
Autronica Fire and Security AS,
Autronica Fire and Security AS
Div. Oil & Gas Europe
Div. Oil & Gas Americas
#B 5F, Saesam B/D
Stalsbergv. 9
10607 Haddington Drive, Suite 100
Sesil-ro, Haeundae-gu
NO-3128 Nøtterøy
Houston, Texas 77043
Busan
Norway
USA
Rep. Of Korea 612-824
Phone: +47 90 90 55 00
Phone: +1 713-290-8624
Phone: +82 70 71229170
E-mail: afs.houston@autronicafire.no Original Spare Parts: Houston.orders@autronicafire.no
AUSTRALIA Autronica Fire and Security AS Division Oil & Gas Australia Level 1, 271-273 Wellingston Road, Mulgrave VIC 3170, Australia Phone: +61 3 9518 5588 Mobile:+ 61 420 538 500
WORLDWIDE SERVICE ASSISTANCE
SPARE PARTS
24 HOUR SUPPORT - END USERS ONLY
Phone: +47 915 09753
Phone: +47 90 90 55 00
Phone: +47 48 25 80 00
E-mail:service.oilgas@autronicafire.no
E-mail: oil.gas@autronicafire.no
For general sales conditions, go to www.autronicafire.com.
70
Autronica Fire and Security AS Petrochemical, Oil & Gas
72
Autronica Fire and Security AS Petrochemical, Oil & Gas
PRODUCTS 2015 PRODUCTS 2015 Omicron Autronica Fire systems and Security Onshore Global
Autronica Fire and Security AS Petrochemical, Oil & Gas
73
Oil and gas installations around the world are becoming a safer place to work. We are bold enough to take some of the credit. For years we have been a preferred supplier of fire and gas safety systems in the petrochemical, oil and gas market throughout the world We make world class products, but believe that even the very best can get better. Appreciative of this, we continuously develop new products whilst providing safety to an entire industry, where thousands of lives depend on them every single day and night. Protecting life, environment, and property
Autronica Fire and Security AS Division Petrochemical, Oil & Gas | Lagerveien 24, NO-4033 Stavanger, Norway +47 90 90 55 00 | oil.gas@autronicafire.no | www.autronicafire.com Org.no.: NO 979 975 503 (MVA/VAT) 116-P-OILANDGAS/SGB, rev. A, 2015-03-09 | Errors and omissions excepted. Changes may occur without warning.