Raxton Brochure

Page 1

ELECTRICAL THREAD CONVERSIONS FOR HAZARDOUS AREAS


Company Overview Raxton Limited have been manufacturers of Electrical Thread Adaptors, Reducers, Stopping Plugs and accessories since 1976. Today Raxton remain committed to products designed to solve the fundamental difficulties which exist due to the variety of thread forms currently in use within the electrical industry. Problems caused by dissimilar threads can occur in both hazardous and industrial environments. Raxton products are fully approved to meet these requirements, being EExd and EExe certified as ATEX, CSA, IECE and GOST Standards. Many products such as Cable Glands, Drain Plugs, Insulating and Earth devices have been added over the years. Raxton now has a worldwide distribution base for its extensive range. Experience shows that our customers are unable to cope with extended deliveries. We recognise the need to respond quickly and have established a reputation throughout the industry for prompt despatch of orders, however large or small. Raxton will continue to offer, alongside its standard range, a bespoke and specials manufacturing service to meet the needs of the market it serves.

Contents EExd Adaptors Insulated Adaptors Right Angle Adaptors Unions Male to Male & Female to Female Adaptors Reducers Stopping Plugs Breather Drain Plugs Compound Stopper Box/Adaptors

4 6 7 8 9 10 12 14 19

Whilst the company continues to expand and develop, Raxton’s principal objective will always be to maintain its high standards of customer satisfaction.

EExe Adaptors Reducers Stopping Plugs Breather - Drain Plugs Earth Lead Adaptors & Threaded Earth Plates

5 11 13 15 18

Accessories Earth Tags Washers Locknuts/Lockrings Screwed Nippling Bushes Shrouds Serrated (Shakeproof ) Washers

16 16 16 17 17 17 17

Technical Information Thread Dimensions Chart Raxton Part Number System Hazardous Area Information Ingress Protection Information

2

20 21 22 23

3


Adaptors EExd

EExe Adaptors

Quality

Quality

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton EExd Adaptors provide a means of connection between dissimilar thread forms or sizes. Certified Adaptors should be used following the basic rules in line with good engineering practice:- No more than one conversion Adaptor should be used at one time on any given cable entry.

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Standard Adaptors have a hexagonal body, where space is a critical factor, Adaptors can be offered with a round body with a diameter equal to the A/F dimension of the standard item. Raxton Adaptors are marked with the applicable approval number and size.

Materials

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton EExe Adaptors provide a means of connection between dissimilar thread forms or sizes. Certified Adaptors should be used following the basic rules in line with good engineering practice:- No more than one conversion Adaptor should be used at one time on any given cable entry. Stopping Plugs should be fitted directly into unused entries of the equipment and not into an Adaptor.

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Metallic Adaptors are supplied with a hexagonal body as standard. Where space is a critical factor Adaptors with a round body can be offered the diameter is equal to the across flat dimensions of the hexagonal body. Nylon Adaptors are produced with a round body.

Materials

EExe Adaptors are supplied fitted with an ‘O’ ring to maintain the IP integrity of the installation.

Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

Type AB HEX

Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104 Nylon: 30% Glass filled Nylon 66

Raxton Adaptors are marked with the applicable approval number and size. Independently tested to IP68.

APPROVALS SIRA 00ATEX1073U

APPROVALS

TYPE AB HEX

IECEx SIR07.0010X

SIRA 00ATEX1073U IECEx SIR07.0010X

CSA 1003277U

GOST POCC GB.M Л14.B00104

GOST POCC GB.M Л14.B00104

Plating

Plating

Raxton Metallic Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Raxton Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Thread Identification

Thread Identification

Type AJ ROUND

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Selection Table on page 20 identifies the standard thread variations produced and is designed to assist the user in the selection process.

Temperature

TYPE AJ ROUND

Temperature

The item is classified as a component and is therefore not given a temperature rating. Nylon temperature range -20°c to 60°c 'O' ring -50°c to 100°c GF Nylon is UL rated @ H.B. @ 1.5mm

The item is classified as a component and is therefore not given a temperature rating.

*

*

*

*

4

Minimum 8 full threads parallel 5 full threads taper

* Thread M20 M25 M32 M40 M50 M63 M75

MALE THREAD MAX BORE MM 14.3 20.5 26.8 33.5 44.0 55.2 66.7

FEMALE THREAD A/F DIMENSION MM 23.37 27.94 37.59 47.24 56.39 70.10 80.01

thread female M16 M20 M25 M32 M40 M50 M63 M75

BORE NYLON 8.0 12.5 17.5 24.5 32.5 42.5 53.0 64.0

BORE head dia head a/f METALLIC nylon mm metallic mm 11.0 24.0 20.8 14.3 27.5 23.4 20.5 35.5 28.0 26.8 41.0 37.6 33.5 50.0 47.2 44.0 60.0 55.9 52.2 75.0 70.0 66.7 85.0 80.0

* Minimum length of thread 10mm

5


EExd Right Angle Adaptors

Insulated Adaptors EExd

Quality

Quality SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton Insulated Adaptors provide a means to isolate the earth of the supply cable from the load equipment thus reducing the risk of damage to electronic equipment within the enclosure in the event of a short circuit to ground through the enclosure. Insulated Adaptors also reduce the problems of electrical noise on the armour affecting the clean earth required by some sensitive instruments. Single point grounding can reduce the circulating current that can cause heating of high capacity cables.

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Cable gland and cable can still be earthed externally with the use of an earth tag fitted between the cable gland and the Insulated Adaptor.

Materials Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104 Nylon: 30% Glass filled Nylon 66

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton Right Angle Adaptors provide a means of connection where protrusion space is limited whilst simultaneously, if necessary, converting the entry thread to that of a different type or reducing size and/or gender of the female thread.

Thread Specification

Right Angle Adaptors can be supplied either with male or female thread entries, or alternatively with female to female thread entries and are marked with the applicable approval number and size.

Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Protrusion dimensions are shown in the table below.

Raxton Insulated Adaptors are marked with the appropriate approval number and size.

Materials Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

TYPE FG Male-Female

TYPE DB

APPROVALS

APPROVALS

SIRA 00ATEX1073U

SIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

GOST POCC GB.M Л14.B00104

Plating

Plating Raxton Insulated Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Raxton Right Angle Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

TYPE FN Female-Female

Thread Identification

Thread Identification

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Temperature

Temperature

The item is classified as a component and is therefore not given a temperature rating. Nylon temperature range max 135°c to -20°c min GF Nylon is UL rated @ H.B. @ 1.5mm

*

* Minimum 6 full threads parallel 5 full threads taper

8 full threads parallel * Minimum 5 full threads taper

6

*

*

*

The item is classified as a component and is therefore not given a temperature rating.

thread protrusion mm M16 45 M20 45 M25 45 M32 45 M40 45 M50 45 M63 45 M75 45

BORE 11.0 14.3 20.5 26.8 33.5 44.0 55.2 66.7

dia mm 30 42 47 54 62 77 87 102

thread Assembly BORE Height mm M16 45 11.0 M20 51 14.3 M25 57 20.5 M32 66 26.8 M40 75 33.5 M50 86 44.0 M63 101.5 55.2 M75 119 66.7

Male Bore Size mm 9 15 20.8 26.8 33.5 44 55 66.5

7


EExd Male to Male and Female to Female Adaptors

Unions EExd Quality

Quality

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton Unions are designed to provide a running joint whilst eliminating exposed threads and are particularly suitable for use where a coupler would be impractical. Unions are available in a variety of thread forms and can be supplied with male to female or female to female thread entries. The female connection thread of the Union shall step not more than one size up from the male connection thread, or equal to one size up in the case of a thread gender change. Eg M20(M) to M25(F) or M20(M) to 3/4 NPT(F).

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Raxton Unions are marked with the appropriate approval number and size.

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Male to Male Adaptors provide a connection between two female threads of the same or dissimilar thread forms. Female to Female Adaptors provide a connection between two male threads of the same or dissimilar thread forms.

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

In each case, thread combinations can reduce by one size of the same thread form or to the equivalent of another form. Eg M25 x M20 M25 x 1/2"NPT Both Male to Male and Female to Female Adaptors are marked with the appropriate approval number and size.

Materials Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

Materials

TYPE FB Male-Female

Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

TYPE AX ROUND

APPROVALS SIRA 00ATEX1073U

APPROVALS

GOST POCC GB.M Л14.B00104

SIRA 00ATEX1073U

Plating

GOST POCC GB.M Л14.B00104

Raxton Unions are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Plating

Thread Identification

Raxton Male to Male and Female to Female Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

TYPE FL Female-Female

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Thread Identification

Temperature

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

TYPE AU HEX

The item is classified as a component and is therefore not given a temperature rating.

Temperature

#

*

*

*

The item is classified as a component and is therefore not given a temperature rating.

* NB for chart below. Bore size on female products is root diameter of the thread.

NB for chart below. Bore size on female products is root diameter of the thread.

# Flamepath in accordance with appropriate standard

8 full threads parallel * Minimum 5 full threads taper

8

thread Protrusion BORE mm M16 53 11.0 M20 53 14.3 M25 53 20.5 M32 53 26.8 M40 53 33.5 M50 53 44.0 M63 53 55.2 M75 53 66.7

dimension A/F mm 30.5 33.0 37.6 47.2 56.0 65.0 80.0 90.0

thread Length BORE Dimension mm A/F mm M16 38 11.0 18.0 M20 38 14.3 23.4 M25 38 20.5 28.0 M32 38 26.8 37.6 M40 40 33.5 41.3 M50 40 44.0 53.0 M63 42 55.2 70.0 M75 42 66.7 80.0

8 full threads parallel * Minimum 5 full threads taper

9


EExe Reducers

Reducers EExd

Quality

Quality SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Raxton EExd Reducers effectively reduce the threaded entry diameter of an enclosure to accept a gland or fitting with a smaller thread. Reducers may also be supplied to accept smaller glands of alternative threads forms.

Raxton EExe Reducers effectively reduce the threaded entry diameter of an enclosure to accept a gland or fitting with a smaller thread. Reducers may also be supplied to accept smaller glands of alternative threads.

Following the basic rules in line with good engineering practices no more than one Reducer should be used at any one time.

Following the basic rules in line with good engineering practices no more than one Reducer should be used at any one time. Stopping Plugs should be fitted directly into unused entries of the equipment and not into a Reducer.

Standard item has a hexagonal head where space is a critical factor Reducers with a circular head can be offered having a diameter equal to the across flats dimension of the hexagonal head (see table below).

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Brass Reducers are supplied with a hexagonal head as standard where space is a critical factor Adaptors with a circular head can be offered with a diameter equal to the across flats dimension of the hexagonal head.

Raxton Reducers are marked with the applicable approval number and size.

Materials

Nylon Reducers are designed with a circular head.

Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

TYPE BJ ROUND

EExe Reducers are supplied with an ‘O’ ring to maintain the IP integrity of the installation. Raxton EExe Reducers are marked with the applicable approval number and size.

APPROVALS

Independently tested to IP68.

SIRA 00ATEX1073U

TYPE BB HEX

IECEx SIR07.0010X

Materials Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104 Nylon: 30% Glass filled Nylon 66

APPROVALS SIRA 00ATEX1073U IECEx SIR07.0010X

CSA 1003277U

GOST POCC GB.M Л14.B00104

GOST POCC GB.M Л14.B00104

TYPE BB HEX

Plating

Plating Raxton Metallic Reducers are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Raxton Reducers are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Selection Table on page 22 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Selection Table on page 22 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Temperature The item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

*

Temperature

* Minimum 8 full * threads parallel 5 full threads taper

NB for chart below. Bore size on female products is root diameter of the thread.

thread

10

Thread Identification

TYPE BJ ROUND

Thread Identification

M16 M20 M25 M32 M40 M50 M63 M75

A/F mm 19.0 23.3 28.0 37.6 47.2 55.9 70.0 80.0

NB for chart below. Bore size on female products is root diameter of the thread.

* Minimum length of thread

The item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c Nylon -20°c to 60°c

10mm

thread head dia head a/f female nylon mm metallic mm M16 22 19.0 M20 25 20.3 M25 30 28.0 M32 38 37.6 M40 46 47.2 M50 56 55.9 M63 70 70.0 M75 81 80.0

11


Stopping Plugs EExd

EExe Stopping Plugs Quality

Quality SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Thread Specification

The range covers four design types:-

Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Tamperproof PLUG Type CF

Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

Thread Specification

Raxton Plugs should be fitted directly into any tapped or untapped entry in the enclosure - mushroom headed plugs are fastened by means of an allen key.

Tamperproof Plugs are inserted from the outside with the allen key towards the enclosure and then tightened from the inside to leave a flush finish to prevent unauthorised removal.

Materials

SIRA (0518) 02 ATEX M207 EN ISO 9001: 2000

Raxton EExe Stopping Plugs are designed to close any unused entries in electrical equipment. Available either with a mushroom head or a hexagonal head they are supplied complete with an ‘O’ ring to ensure that the IP rating of the installation is maintained.

Raxtons' comprehensive range of Stopping Plugs are designed to close any unused entries in electrical equipment without revoking existing certification.

Isometric (ISO) to BS3643:1981 or ISO 965 Pts 1&3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Raxton EExe Plugs are marked with the appropriate approval number and size. Tested to IP68

Materials Brass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 BS2874:1986 CA104 Nylon: 30% Glass filled Nylon 66

HEXAGON HEAD Type CK

Hexagon Head Plugs are inserted from the outside and tightened with a spanner. They are fitted with an 'O' ring as a norm but can be used with a washer if preferred.

RX PLUG Type CB

RX Plugs are inserted with the allen key pointing away from the box and tightened from the outside.

APPROVALS SIRA 00ATEX1073U

APPROVALS

IECEx SIR07.0010X

SIRA 00ATEX1073U

CSA 1003277U

IECEx SIR07.0010X (metalic only)

Hexagon Head Plug Type CK

GOST POCC GB.M Л14.B00104

GOST POCC GB.M Л14.B00104

Hexagon Headed Plugs are inserted from the outside and fastened by means of a spanner. (Across flats dimensions are listed below).

Plating Raxton Stopping Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Plating DOME HEAD TYPE CQ

They can be fitted with a washer to increase the IP rating of the assembly

Thread Identification

DOME HEAD PLUG TYPE CQ

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Raxton Metallic Stopping Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Dome Head Plugs are inserted from the outside using an allen key. They are fitted with an 'O' ring as a norm but can be used with a washer if preferred.

Can be offered as an alternative to the Hexagon Headed version

Thread Identification Selection Table on page 22 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Temperature The item is classified as a component and is therefore not given a temperature rating.

Temperature 8 * Minimum full threads parallel 5 full threads taper

*

The item is classified as a component and is therefore not given a temperature rating. 'O' ring -20°c to 60°c Nylon -50°c to 100°c

Following the basic rules in line with good engineering practice Raxton Stopping Plugs should be inserted directly into the unused entry and not into a thread Reducer or thread Adaptor.

#

*

*

12

*

thread RX & TP DOME Hexagon head allen key allen key A/F mm M16 6 6 19.0 M20 10 10 23.3 M25 10 10 28.0 M32 10 10 37.5 M40 10 19 47.0 M50 10 19 56.0 M63 10 19 70.0 M75 10 19 80.0

thread A/F DOME head dia mushroom hex plug mm ALLEN KEY plug mm M16 19.0 6 20.5 M20 20.8 10 25.0 M25 28.0 10 30.0 M32 37.6 10 38.0 M40 47.2 19 46.0 M50 55.9 19 56.0 M63 70.0 19 69.0 M75 80.0 19 81.0

* 15mm Standard across flats for M16 to M32. # 10mm 19mm across flats for M40 to M75

13


Breather - Drain Plugs EExd

EExe Breather - Drain Plugs

Quality

Quality

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Thread Specification Isometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 National Pipe Thread (NPT) to ANSI/ASME:1983

a) into a chamfered plain hole using drainage washer and locknut or castellated locknut on the inside of the enclosure.

The 'O' ring will seal against the enclosure face enhancing the I.P. rating of the Plug.

APPROVALS SIRA 00ATEX1288U

Brass: BS2874: 1985 CZ121 Nylon: 30% Glass filled Nylon 66 Stainless Steel: BS970 PT3 316 S11

The Drain Plug can be supplied with either a serrated washer and locknut allowing the condensation to drain whilst ensuring the Plug is shakeproof or with a castellated locknut.

Tested to IP66

Plating

Materials

b) directly into a threaded hole provided that, if the thread protrudes, the drainage hole is visible.

The Breather/Drain Plug has an impact resistance of 20 Nm and can operate at temperatures between -50°c to +230°c

IECEx SIR08.0127U

Isometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

The Drain Plug can be fitted:

The plug is an assembled item and must not be taken apart at any stage of installation.

Brass: BS2874: 1985 CZ121 Stainless Steel: BS970 PT3 316 S11

Thread Specification

Fastened by means of an allen key the Drain Plug should be fitted at the lowest point of the enclosure.

The Plug is fastened to the lowest point of the enclosure by means of a spanner.

Materials

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Raxton EExe Drain Plugs effectively drain any moisture build-up present within the enclosure whilst allowing air in the enclosure to breathe with the surrounding atmosphere minimising moisture build up within the enclosure.

The Raxton Exd Breather/Drain Plug is designed to: 1) effectively drain moisture from an enclosure, 2) allow air from the enclosure to vent into the surrounding atmosphere thereby minimising moisture build up and 3) provide the explosionproof safety required by a hazardous area environment.

APPROVALS

The Drain Plug is fitted with an ‘O’ ring as standard ensuring that the IP integrity of the installation is maintained.

Raxton Metallic Drain Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

SIRA 00ATEX3074U GOST POCC GB.M Л14.B00104

Raxton Drain Plugs are marked with the appropriate approval number and size.

Temperature

TYPE CTA

Plating

Tested to IP66

Raxton Metallic Drain Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

-50°c to 230°c

TYPE CV

Thread Identification Selection Table on page 22 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Temperature The item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

TYPE CTE

*

8 full threads parallel * 5Minimum full threads taper

14

*

THREAD HEX A/F M20 27.0 (1.062) M25 31.75 (1.25) 1/2” NPT 27.0 (1.062) 3/4” NPT 27.94 (1.1)

THREAD LENGTH 16 16 20.0 20.0

OAL 31 31 35 35

Thread diameter allen mm key mm M20 25.4 10 M25 30.5 10 M32 38.0 10 1/2” NPT 25.4 10 3/4” NPT 30.5 10 1” NPT 38.0 10

head protrusion mm 14 14 14 14 14 14

* 10mm Standard

15


Accessories

Accessories Earth Tags

Raxton Earth Tags provide a means of connecting a flexible earth bond with the gland, thread Adaptor or thread Reducer in any required position whilst ensuring suitable earth continuity. Available in Brass, Aluminium and Stainless Steel and supplied self colour as standard additional plating is available if required.

Screwed Nippling

Supplied 50mm long as standard, alternative lengths can be supplied as required. Available in a variety of thread forms (see page 22). Materials include Brass, Mild Steel, Stainless Steel, Aluminium and Nylon. Metallic finishes can be plated to requirements.

Couplers

Available in round or hexagonal. Manufactured in Brass as standard, they can be supplied with either similar or dissimilar threads at each end in a wide combination of thread forms and sizes.

Bushes

Male and Female Bushes are available in a variety of thread forms (see page 22). Materials include Brass, Mild Steel, Stainless Steel, Aluminium and may be plated to requirements.

Washers

To maintain the IP rating of the equipment Raxton offer a wide variety of entry thread sealing Washers and ‘O’ rings. Materials include Nylon, Teflon, Neoprene, Fibre, and Rubber. In addition Raxton can offer a non setting universal jointing sealant.

Locknuts/Lockrings

Raxton offer a large variety of Locknuts/Lockrings which are often recommended for securing cable glands, thread Adaptors or thread Reducers to a gland plate or into equipment. Locknuts are available in Brass, Mild Steel, Stainless Steel, Aluminium or Nylon.

Shrouds

Raxton offer a range of push on Shrouds which are used to minimise the risk of dirt or foreign substances gathering on the cable gland body and /or point of cable to the gland interface. Supplied as standard in black PVC they are suitable for all leading makes of glands.

16

Serrated (Shakeproof) Washers

Raxton Serrated Washers are available in both Mild Steel Zinc plated and Stainless Steel and prevent the risk of attachments becoming loose when used in conjunction with a Locknut.

17


Earth Lead Adaptors Threaded Earth Plates EExe

EExd Compound Stopper Box/Adaptor

Quality

Quality

SIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

Earth lead Adaptors

Raxton EExe Earth Lead Adaptors allow for earth continuity to be maintained by providing an earth lead which can be terminated inside the enclosure. Earth Lead Adaptors are produced with an undercut and supplied complete with an ‘O’ ring to maintain the IP integrity of the installation. Earth Lead Adaptors are marked with the appropriate approval number and size.

Thread Specification Isometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3 National Pipe Thread (NPT) to ANSI/ASME:1983

Materials Brass: BS2874: 1985 CZ121 Stainless Steel: BS970 PT3 316 S11

TYPE DG Adaptors Type DN Reducers

APPROVALS

Raxton Compound Stopper Box is designed to seal conductors at the entry to the enclosure via conduit or to enable an existing compression gland to be converted to a barrier gland. This is achieved by forming a barrier between the individual insulated conductors within the cable to prevent an explosion within the enclosure. The Compound Stopper Box allows compound to be packed around individual insulated conductors. Assembly of the component compresses the packing material and distributes the compound evenly to effect a barrier at point of entry into the enclosure. The Compound Stopper Box is supplied with compound in a pack, complete with making off instructions and gloves. Raxton Compound Stopper Box is marked with the appropriate approval number and size.

SIRA 00ATEX1073U GOST POCC GB.M Л14.B00104

Plating

SIRA (0518) 02 ATEX M207 EN ISO 9001: 2000

Thread Specification Isometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

Materials Brass: BS2874: 1985 CZ121 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

APPROVALS

Raxton Earth Lead Adaptors/Plates are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

SIRA 00ATEX1073U GOST POCC GB.M Л14.B00104

Thread Identification

TYPE EG

Threaded Earth Plate

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

Plating

Raxton EExe Threaded Earth Plates are designed to ensure earth continuity when terminating brass glands into non metallic enclosure. The additional use of a locknut is recommended to ensure pressure is maintained with the wall enclosure. Threaded Earth Plates are marked with the appropriate approval number and size.

Temperature

Raxton Stopper Boxes are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

Thread Identification

The item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

Selection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

TYPE DK

Temperature The item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

*

*

* Minimum length of thread 10mm

18

thread Material cable x earth plate size (mm) 300mm (mm2) M16 22 2.5 M20 30.0 2.5 M25 32.0 4.0 M32 38.0 6.0 M40 50.8 10.0 M50 63.5 16.0 M63 76.0 25.0 M75 102.0 25.0

thread length earth Lead X earth lead mm 300mm (mm2) M16 38 2.5 M20 38 2.5 M25 38 4.0 M32 38 6.0 M40 39 10.0 M50 39 16.0 M63 39 25.0 M75 39 25.0

thread Bore thread protrusion min mm length mm mm M16 7.20 15 32.0 M20 12.50 15 34.5 M25 18.25 15 34.5 M32 24.30 15 34.5 M40 30.00 17 35.0 M50 41.60 17 37.0 M63 53.25 17 37.0 M75 65.00 17 37.0

8 full threads parallel * Minimum 5 full threads taper

19


Thread Dimension Chart

Raxton Part Number System FEMALE THREAD

16.93

1.5

11.0

16

M16

16.93

1.5

15.0

20

M20

16.93

1.5

20.5

25

M25

16.93

1.5

26.8

32

M32

16.93

1.5

33.5

40

M40

16.93

1.5

44.0

50

M50

16.93

1.5

55.2

63

M63

16.93

1.5

66.7

75

M75

14

1.81

14.3

21.34

1/2” NPT

14

1.81

20.5

26.67

3/4” NPT

111/2

2.20

26.8

33.40

1” NPT

111/2

2.20

33.5

42.16

1 1/4” NPT

111/2

2.20

41.0

48.26

1 1/2” NPT

111/2

2.20

54.0

60.33

2” NPT

8

3.175

64.5

73.03

2 1/2” NPT

8

3.175

79.0

88.90

3” NPT

8

3.175

90.0

101.60

3 1/2” NPT

8

3.175

101.0

114.30

14

1.81

P T 15.5 14.3

14

1.81

14 11

4” NPT

3 1/2” NPT

3” NPT/BSP

2 1/2” NPT/BSP

2” NPT/BSP

1 1/2” NPT/BSP

1 1/4” NPT/BSP

1” NPT/BSP

3/4” NPT/BSP

1/2” NPT/BSP

M75/3” ET

M63/21/2” ET

PLUGS

INSULATING AND EARTHING

CABLE RETENTION

CODE

BRASS ALUMINIUM STEEL COPPER & NON-ASB STAINLESS STEEL PVC NYLON BLACK NYLON GREY SILICONE NYLON BLUE LEAD GLASS FILLED NYLON NYLON 66 RED FIBRE TEFLON EPDM NYLON WHITE SPECIAL

A B C

M-F HEX

AB

M-F ROUND

AJ

M-M

AR

F-F HEX

AU

F-F ROUND

AX

M-F HEX

BB

M-F ROUND

BJ

RX

CB

TAMPERPROOF

CF

HEX HEAD

CK

DOME HEAD

CQ

SLOTTED

CS

DRAIN

CV

INSULATED M x F

DB

INSULATED M x M

DD

INSULATED F x F

DE

EARTH LEAD M x F

DG

EARTH PLATE

DK

EARTH TAG

DM

GC

1.81

21.5 20.0

26.44

3/4” BSP

LOCKNUT CASTELLATED

GD

2.31

26.8 25.5

33.25

1” BSP

WASHERS

HA

O RINGS

HB

SHROUD

HC

75.18

2.31 2.31

66.0 62.0 77.0 73.0

87.88

ACCESSORIES

3” BSP Reducers

Adaptors

Not Certified

3/4"

53

63

44

1"

54

64

M12

04

1 1/4"

45

1 1/4"

55

65

M16

11

1 1/2"

46

1 1/2"

56

66

M20

12

2"

47

2"

57

67

M22

07

2 1/2"

48

2 1/2"

58

68

M24

08

3"

49

3"

59

69

M25

13

3 1/2"

86

4"

79

89

M28

09

4"

87

SPECIAL

50

60

M32

14

5"

88

M38

05

M40

15

M50

16

M63

17 18

10

SERRATED WASHERS

2 1/2” BSP

43

1"

SPECIAL

5/8” BSP

2” BSP

3/4"

03

A D E

22.91

59.61

02

Atex EExde Atex EExd Atex EExe Mining Group 1 CSA © Exd11C CSA (US) Class 1 Zone 1 AExd 11C IECEx Exd 1/11C IECEx Exe 1/11 Gost Exde 11CU Gost Exde 1/11CU Gost Exd11CU Gost Exe11U

MALE BUSH LONG

JA

MALE BUSH SHORT

JB

FEMALE BUSH

JC

NIPPLE

JD

NIPPLE LONG

JE

NIPPLE BARREL

JF

COUPLER ROUND

JG

COUPLER HEX

JH

COUPLER FLANGE

JJ

All codes marked

J K L N P T U V W

CODE

M8

82

M

SIZE

M10

81

17.5 16.3

53.0 50.0

62

M90

GB

2.31

52

M100

GA

11

1/2"

APPROVALS

LOCKNUTS

1 1/2” BSP

42

DIGIT 8

LOCKRINGS

47.80

1/2"

EK

1/2” BSP

41.0 39.0

01

FB

20.96

2.31

M6

UNION M-F

FK

11

N U P Q R S

CODE

STOPPER BOX F-F

RIGHT ANGLE M-M

1 1/4” BSP

M

SIZE

80

4” NPT

41.91

F G H J K L

BSP P

CODE

M80

FN

35.0 33.0

E

BSP T

SIZE

EG

RIGHT ANGLE F-F

I.P. AIDS

D

NPT

CODE

STOPPER BOX M-F

FG

LOCKING

ISOMETRIC SIZE

EB

RIGHT ANGLE M-F

FEMALE DIGIT 6 + 7

THREAD REFERENCES AS TABLE BELOW

GLAND

FL

ADAPTING AIDS

MALE DIGIT 4 + 5

M75

FE

CERTIFIED

20

M50/2” ET

M40/11/2” ET

REDUCERS

DIGIT 3

UNION F-F

2.31

11

ADAPTORS

CODE

UNION M-M

11

11

M32/11/4” ET

Size

M25/1” ET

PITCH

MAJOR BORE Size DIAMETER MAX MM

M20/3/4” ET

ThreadS PER INCH

M16/5/8” ET

MALE THREAD

DIGIT 1+2

Normally male thread is specified first (4+5) Female thread second (6+7) with items then both M-M or F-F sets of digits will be used Pg & ET thread components are still available please consult sales department for advice. SPECIAL

40 Examples

1/2”NPT M20F Adaptor Brass EExd AB A 42 12 D

Reducer BB

GF Nylon M50 M M 16

Locknut GA

Brass A

Hex Head Plug CK

ST/ST E

1”NPT F 44

- M63 00 17 2”BSPT 57

EExe E

PART NUMBER = ABA4212D

= BBM1644E

- l

= GAA0017

- GOST EExd 11CU 00 V = CKE5700V

cover products which are not certified or have any associated approvals

21


Hazardous Area

Ingress Protection Information

Grouping of Electrical Apparatus for potentially explosive atmospheres GROUP I GROUP II

ELECTRICAL APPARATUS FOR MINING, TYPIFIED BY THE GAS METHANE (FIREDAMP) ELECTRICAL APPARATUS FOR SURFACE INDUSTRY Group II may be further divided into three gas groups: IIA - Representative Gas Propane IIB - Representative Gas Ethylene IIC - Representative Gas Hydrogen Gas Group IIC covers the most hazardous gases and as such, apparatus marked IIC may be used in IIA and IIB applications.

DUST

ZONE

0

20

ZONE

1

21

ZONE

2

22

Zone in which an explosive atmosphere is constantly present, or present for long periods. (Rough guide: hazard present for more than 1000 hours/year). Zone in which an explosive atmosphere is likely to occur in normal operation. (Rough guide: hazard present between 10 & 1000 hours/year).

60079-11

61241-11

60079-18

61241-18

0

2

3 CODE

GAS

PROTECTION CONCEPT

Ex d Ex p Ex q Ex o Ex e Ex ia Ex ib

Ex ma Ex mb

ZONE

DUST

Ex tD Ex pD

Ex iaD Ex ibD

Ex nA Ex nL Ex nR Ex nC Ex nP

60079-15

0

Zone in which an explosive atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. (Rough guide: hazard present for less than 10 hours/year). Guidance in the classification of hazardous areas is given in BS EN 60079-10:1996, IEC79-10.

Protection Concepts STANDARD IEC/EN GAS DUST 60079-0 61241-0 60079-1 61241-1 60079-2 61241-2 60079-5 60079-6 60079-7

Second Number - Water

1

CLASSIFICATIONS GAS

First Number - DUST

Ex maD Ex mbD

GAS General Requirements Flameproof Enclosure Pressurised Powder Filled Oil Filled Increased Safety Intrinsic Safety Non-sparking Energy Limited Restricted breathing Enclosed break Pressurisation

2

Encapsulation

0 1

50

12.5

Protected against solid foreign objects of 50mm ø and greater. The object probe, sphere of 50mm ø, shall not fully penetrate†

Protected against solid foreign objects of 12.5mm ø and greater. The object probe, sphere of 12.5mm ø, shall not fully penetrate†

Protected against solid foreign objects of 2.5mm ø and greater. The object probe, sphere of 2.5mm ø, shall not fully penetrate† at all.

Non-protected

Protected against vertically falling water drops.

1

Vertically falling drops shall have no harmful effects.

Protected against vertically falling water drops when enclosure tilted up to 15º.

2

Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15º on either side of the vertical.

Protected against spraying water.

3

Water sprayed at an angle up to 60º on either side of the vertical shall have no harmful effects.

DUST

1 1 1 1 1 0 1

Non-protected

20/21/22 21/22

4

Protected against solid foreign objects of 1.0mm ø and greater. The object probe, sphere of 1.0mm ø, shall not fully penetrate† at all.

Protected against splashing water.

4

Water splashed against the enclosure from any direction shall have no harmful effects.

Dust Protected.

20 21

5

Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of apparatus or to impair safety.

6

Dust-tight

Protected against water jets.

5

Water projected in jets against the enclosure from any direction shall have no harmful effects.

Protected against powered water jets. No ingress of dust

6

Water projected in jets against the enclosure from any direction shall have no harmful effects.

20 21

*in some countries the methods of protection a & q are allowed in Zone 1.

7

Temperature Class Explosion protected electrical apparatus must be designed and tested to ensure that the maximum surface temperature of any part(s) of the products are below the ignition temperature of the explosive atmosphere concerned. Group II electrical apparatus is divided into temperature classes according to the maximum permissible surface temperature of the apparatus. The preferable classification of temperatures is given in the following table:Unless otherwise specified the maximum ambient temperature is taken to be 400ºC.

Temperature Class

22

T1 T2 T3 T4 T5 T6

8 † The full diameter of the object probe shall not pass through an opening of the enclosure

15CM MIN 1M

Protected against the effect of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible when enclosure is temporarily immersed in water under standardised conditions of pressure and time. Protected against the effect of continuous immersion in water. Ingress of water in quantities causing harmful effects shall not be possible when enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7.

Maximum Surface Temperature (Degrees Celsius) 450 300 200 135 100 85

23


A5

12

LIChFIELd

Cannock A5

M6

A5

Brownhills

M54

Raxton Limited Westgate, Aldridge, West Midlands WS9 8FS Tel: +44 (0) 1922 450400 Fax: +44 (0) 1922 450401 Email: enquiries@raxton.co.uk Web site: www.raxton.co.uk

A452

10a

WOLVErhAMpTON

A38 A5

A5127

A34

ALdrIdgE

A454

A454

TAMWOrTh

WALSALL

9

A452

10

Sutton ColdямБeld

7

8

9

A452 A38

1

6

5

8

4a

7 7a 4

BIrMINghAM

2

A5

M42

A38

M6

M5

West Bromwich

A5

A38

A452

M6

10

dudLEY

A38

A5

M6

A38

M5

6 M42

B 4 152

A 46

1

d rOA ALL

NOrThgATE

LS WA

LIC h

FIEL

dr

B4 1 5 2

OAd

54 B41

STu BBE rS

LS

NE

NE

grE EN

LA

S

AC h

d pAd

LA

54 gE rd A4 ALdrId A454

YL

O Ck

ST

AN

E

A454 LIT

Nr

S TO

A rY L

BO

rF A

A TLE

E

dEr

54

B

41

W hA

rd Od

BL E

d LAN E

LEI gh WO

pp

rO

A46 1

du M

NE LA

W EN

rOA d

N

AT STg WE

Y

LIChFIE Ld rO Ad

E rL TE WI

dA

BAr

B4152

BArN LANE

d

d A4 54

54 B41

A461

A

LA

Lr

pE

LL

WALS A

L

B415 4

issue 09


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.