General catalogue Commercial Range

Page 1

General catalogue COMMERCIAL AND TECHNICAL INFORMATION Commercial Range


Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the highest technological standards. For over 30 years BAXI SPA has provided a wide range of cutting-edge solutions, anticipating market evolutions and paying attention to customer needs.

How to read this catalogue In this catalogue we show the high efficiency condensing system complete range of BAXI products. On each page, in addition to the product benefits, there is a detailed list of the appliance characteristics, a technical chart, and coloured icons. These icons refer to the specific pages of the technical section of the catalogue where, by segment, the technical drawings and all the specific accessories are represented.

In the technical section you will find:

Dimensional Flue tube technical accessories drawings Graphs Flue systems

2

Hydraulic accessories

Thermoregulation accessories

Other accessories


High efficiency condensing systems

More details and information on the website By accessing to the www.baxi.it, Reserved Area and then to the Tech Area, just after a quick registration it is possible to display and download the following documents:

• Certifications • Fault Finding List • General Catalogues • General informations catalogues of all Baxi products • Instructions Manuals • PCB Service Instructions • Spare Parts Catalogues • Technical Drawings • Technical INFO

Index High efficiency condensing boilers

6

Built-in heat-boxes - Luna Sat

8

Luna Platinum 12 - 32 kW

10

Luna Duo-tec MP 50 - 110 kW

11

Luna HT 45 - 100 kW

12

Cabinets (GMC)

13

Power HT 45 - 150 kW

15

Power HT 230 - 320 kW

16

Luna Sat

17

Technical section

19

3


Condensing technology is the latest face in boiler innovation. By employing pre-mix burner know how, condensing boilers ensure higher performance (efficiency up to 109,8%) thanks to the recovery of all the heat available through combustion without wasting energy into the air, as happens with traditional boilers.

4


High efficiency condensing systems High efficiency installations Baxi condensing systems represent the ideal solution for installations where high outputs are required. The electronics platform of these boilers allows the control of single and cascade installations and a complete range of thermoregulation accessories. It is therefore possible to have high energetic efficiency system ensuring low emissions and meeting any domestic comfort needs, total control, DHW at the right comfort level always in the maximum respect of the environment.

High modulation ratio The new ranges of high efficiency condensing boilers are distinguished by a wider modulation ratio that grants a better efficiency thanks to reduced switch-on/ switch-off of the boiler.

Cutting edge electronics The sophisticated electronics of the high efficiency condensing boilers allows to manage single or cascade installation up to 16 boilers (Luna Duotec MP or Power HT 230-320). It is just needed to connect the relevant accessories to the boiler’s electronics.

Compact weight and dimensions Compact weight and dimensions of Baxi high efficiency condensing systems, guarantee the maximum flexibility and allow their installation also in small heat generator rooms. 5


High efficiency wall hung condensing boilers Luna Platinum 1.12/1.18

Luna Platinum 1.24

Luna Platinum 1.32

High efficiency wall hung condensing boilers Luna Duo-tec MP 1.50

Luna Duo-tec MP 1.60

High efficiency floor standing condensing boilers Power HT 1.450

Maximum Heat Output

80째/60째 C

32 12/16,9

24

Luna Platinum HT

33,8

45

kW

Luna Duo-tec MP

Maximum Heat Output

34,9

48,6

Luna Platinum HT

Luna Duo-tec MP

36,6

48,7

Luna Duo-tec MP

Power HT

50째/30째 C kW

13,1/18,4

26,1

55

59,4

A wide range of high efficiency solutions

6


High efficiency condensing systems

Luna Luna Luna Duo-tec MP Duo-tec MP Duo-tec MP 1.110 1.90 1.70

Power HT 1.650

Power HT 1.850

Power HT 1.1000

Power HT 1.1150

Power HT 1.1200

Power HT 1.1500

Power HT 1.230

Power HT 1.280

Power HT 1.320

112

120

150

210,1

254,5

294

162

229,8

278,1

321,3

102 65

85

Luna Duo-tec MP

100 Power HT

70,2

91,8

110,2

Luna Duo-tec Luna Duo-tec Luna Duo-tec MP MP MP

70,3

91,6

107,8

Power HT

Power HT

Power HT

121,1 129,7

Baxi high efficiency condensing systems are available in a wide range of outputs from 12 to 320 kW, to satisfy every installation need (wall hung and floor standing).

7


Wireless and M-BUS built-in heat boxes Without pump (mixing valve)

With pump

To manage 2 zones

Luna SAT RC - Luna SAT RC-MB Luna SAT R/1 - Luna SAT R/1-MB Luna SAT RH - Luna SAT RH-MB Luna SAT RH1 - Luna SAT RH1-MB Luna SAT RHG1 - Luna SAT RHG1-MB

Luna SAT RP/1 - Luna SAT RP/1-MB Luna SAT RPH - Luna SAT RPH-MB Luna SAT RPB - Luna RPB-MB Luna SAT RPE - Luna SAT RPE-MB Luna SAT RPEH - Luna SAT RPEH-MB

Luna SAT R2Z Luna SAT R2Z-MB

Luna SAT RS - Luna SAT RS-MB Luna SAT RST-MB

Luna SAT RSP - Luna SAT RA Luna SAT RSP-MB Luna SAT R60 WH-MB (for wall hung installation with integrated cylinder)

Luna SAT RS2Z - Luna SAT RA2Z

Heating only

Combi

Heating and cooling

Luna SAT R2H - Luna SAT R2H-MB

- Luna Sat R/1, RH, RPB, RPE, RPEH, RH1 and RHG1 and RHG1 are available also with built-in flow-meters (M-BUS models as well) - RH1 and RH1-MB models are available also with pressure reducer on the flow-meters.

8


High efficiency condensing systems

High efficiency condensing systems Thermal systems for cascade installations Wall hung boilers - Luna Platinum - Luna Duo-tec MP - Luna HT (range available only for installation in GMC) - Cabinets with condensing high efficiency boilers (GMC)

10 11 12 13

Floor standing boilers - Power HT (outputs from 45 to 150 kW) - Power HT (outputs from 230 to 320 kW)

15 16

Wireless and M-BUS built-in heat boxes - Luna Sat-Heating only models - Luna Sat-Heating and DHW production models

17 18

9


Technical pages 20-28 33-39

40

41-42

Luna Platinum 12-32 kW • Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Integrated control of a solar system* • Complete soundproofing of the generator • Circulating pump with full modulation • Frontal access for advanced diagnostics

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhaced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Multi-speeds low energy pump of the heating circuit with builtin air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Cascade system installation option Room sensor, central heating and sanitary timers included in the control panel

Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital central heating pressure gauge *in case of contemporary control of a solar system and a zone by the wallmounted control panel, it is necessary to install a programmable clip in/external module THINK.

10

Product code

1.12

1.18

1.24

1.32

7102665

7108435

7106583

7108436

Maximum heating heat input

kW

12,4

17,4

24,7

33

Maximum heating heat output 80/60°C

kW

12

16,9

24

32 34,9

Maximum heating heat output 50/30°C

kW

13,1

18,4

26,1

Minimum heating heat output 80/60°C

kW

2

2,4

2,4

3,2

Minimum heating heat output 50/30°C

kW

2,2

2,7

2,7

3,5

´´´´

´´´´

´´´´

´´´´

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,8

97,7

97,6

97,6

Nominal efficiency 50/30°C

%

105,8

105,8

105,7

105,7

Efficiency 30%

%

107,8

107,7

107,6

107,6

5

5

5

5

-5

-5

-5

-5

Energetic efficiency (92/42/CEE)

NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge

°C l/bar

8/0,8

8/0,8

8/0,8

10/0,8

Heating temperature range.

°C

25/80

25/80

25/80

25/80

Maximum pressure heating circuit

bar

3

3

3

3

m

10

10

10

10

Coaxial flue system Ø 60/100 max length

m

80

80

80

80

Maximum flue mass flow rate

Dual flue system Ø 80 max length

kg/s

0,006

0,008

0,012

0,016

Minimum flue mass flow rate

kg/s

0,001

0,001

0,001

0,002

Maximum flue temperature

°C

75

75

80

80

Dimensions (h x w x d)

mm

Net weight

kg

34,5

34,5

760 x 450 x 345

Gas type Power consumption Grade of protection

34,5

37,5

Natural Gas W

108

122

120

130

IPX5D

IPX5D

IPX5D

IPX5D


High efficiency condensing systems Technical pages 21-30 33-39 39-40 41-43

Luna Duo-tec MP 50-110 kW • Stainless steel AISI 316L single chamber (50 – 60 – 70 kW) and double chamber (90 – 110 kW) exchanger: high output in compact size, reliability and long life. • High modulation ratio (1÷9): better efficiency thanks to reduced switch-on/switch-off of the boiler • Digital control panel with push buttons and wide LCD display (numbers and symbols) • Compact size and minimal weight • Complete range of accessories for single and cascade installations

Outputs from 50 to 110 kW Hydraulic system Modulating pump included in the boiler System to prevent pump sticking operating every 24 hours Flow and return NTC sensors Water tray for condensate drain from supply air duct

Thermoregulation system Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (high and low temperatures) installation option Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the control panel

Product code

1.50

1.60

1.70

1.90

1.110

7104050

7104051

7104052

7104651

7104652

Maximum heating heat input

kW

46,3

56,6

66,9

87,4

104,9

Maximum heating heat output 80/60°C

kW

45

55

65

85

102

Maximum heating heat output 50/30°C

kW

48,6

59,4

70,2

91,8

110,2

Minimum heat output 80/60°C

kW

5

6,1

7,2

9,4

11,4

Minimum heat output 50/30°C

kW

5,4

6,6

7,8

10,2

12,3

Energetic efficiency 92/42/CEE

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,2

97,2

97,2

97,2

97,2

Nominal efficiency 50/30°C

%

105

105

105

105

105

Efficiency at 30%

%

107,8

107,4

107,1

107,5

107,4

5

5

5

5

5

NOx class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

-5

Water content

lt

4

5

6

9

10

Heating system max pressure

bar

4

4

4

4

4

Safety valve intervention pressure

bar

4

4

4

4

4

Regulation of water temperature in heating circuit

°C

25/80

25/80

25/80

25/80

25/80

Control system Full electronic anti-frost device Electronic thermometer Central heating pressure gauge Flow over-temperature thermostat

Coaxial flue system max length

m

10 (Ø 80/125)

10 (ø 80/125)

10 (ø 80/125)

10 (ø 110/160)

10 (ø 110/160)

Dual flue system max length

m

60 (ø 80)

60 (ø 80)

60 (ø 80)

27 (ø 110)

27 (ø 110)

Maximum flue mass flow rate

kg/s

0,021

0,026

0,031

0,04

0,047

Minimum flue mass flow rate

kg/s

0,002

0,003

0,004

0,005

0,005

Maximum flue temperature

°C

80

80

74

70

70

Dimensions (h x w x d)

mm

766x450x377

766x450x377

766x450x505

952x600x584

952x600x584

Net weight

kg

40

40

50

83

93

Nat. gas/LPG

Gas type Power consumption Grade of protection

W

190

210

210

275

320

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

11


Luna HT 45-100 kW • Stainless steel double chamber exchanger: high output in compact size, reliability and long life • Digital control panel “advanced CPS system” with push buttons and wide LCD display with text and symbols • Minimal weight and size • Complete range of accessories for the climatic control • Range available only for installation in GMC

Outputs from 45 to 100 kW Hydraulic system Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue exchanger System to prevent pump sticking operating every 24 hours

Thermoregulation system Remote controller and climatic regulator (supplied as optional) Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (low and high temperature) installation option Cascade system installation option NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the

1.450 Product code

1.450P*

1.550

1.650

1.850

1.1000

HSB 43545300 43545364 43555300 43565300 43508500 43510000

Maximum heating heat input

kW

46,4

46,4

56,7

67

87,2

105

Maximum heating heat output 80/60°C

kW

45

45

55

65

85

102

Maximum heating heat output 50/30°C

kW

48,7

48,7

59,5

70,3

91,6

110,3

Minimum heat output 80/60°C

kW

14,5

14,5

15,5

19,3

25,7

29

Minimum heat output 50/30°C

kW

15,8

15,8

16,8

21

27,8

31,4

Energetic efficiency 92/42/CEE

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,3

97,3

97,4

97,4

97,5

97,4

Nominal efficiency 50/30°C

%

105,1

105,1

105,0

105,2

105,1

105,1

Efficiency at 30%

%

107,6

107,6

107,5

107,6

107,3.

107,4

5

5

5

5

5

5

NOx class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

-5

-5

Water content

lt

5,1

5,1

5,6

6,5

13,7

21

Heating system max pressure

bar

4

4

4

4

4

4

Safety valve intervention pressure

bar

3

3

3

3

3

3

Regulation of water temperature in heating circuit

°C

25/80

25/80

25/80

25/80

25/80

25/80

Control system

Coaxial flue system max length

m

10 (ø 80/125) 10 (Ø 80/125) 10 (ø 80/125)

10 (ø 80/125) 10 (ø 110/160) 10 (ø 110/160)

Central heating and indirect cylinder timer Hydraulic pressure switch to prevent boiler operating in the event of low water Full electronic anti-frost device Electronic thermometer Central heating pressure gauge

Dual flue system max length

m

60 (ø 80)

60 (ø 80)

60 (ø 80)

60 (ø 80)

Maximum flue mass flow rate

kg/s

0,022

0,022

0,027

0,032

0,041

0,050

Minimum flue mass flow rate

kg/s

0,007

0,007

0,008

0,010

0,013

0,015

Maximum flue temperature

°C

74

74

78

75

74

79

Dimensions (h x w x d)

mm

950x600x466

950x600x466

950x600x466

950x600x466

950x600x650

950x600x650

Net weight

kg

64

64

68

72

94

98

control panel

Nat. gas/LPG

Gas type Power consumption Grade of protection

12

(*) Model with integrated pump

27 (ø 110) 27 (ø 110)

W

75

75

80

125

150

200

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D


High efficiency condensing systems Technical pages

22

Cabinets with condensing high efficiency boilers (GMC) • Minimum overall dimensions and maximum compactness • Easy installation in heating systems renovation • High flexibility: possibility to connect up to 3 cabinets with flow and return hydraulic connections on the left or on the right side • Easy installation and quick connection • Easy handling with a mechanical power-lift option • Suitable for outdoor installation • Hydraulic accessories for cascade installation

CABINET made of:

N° of installed Boilers

LUNA HT possible configuration

1.450 1.550 1.650

Hydraulic system Hydraulic connections between boilers and copper collectors Integration of the hydraulic safety accessories Expansion vessels included Flow/return right or left side

2

or

doors* 1.850 1.1000

3

1.450 1.550 1.650

or

doors* 1.850 1.1000

Tot. installed kW

45 55 65 85 90 100 110 120 130 170 185 200

90 100 110 120 130 135 145 155 165 170 175 185 195 200 255 270 285 300

* to install the hydraulic compensator and the system accessories sheltered from the bad weather it is possible to order an additional cabinet

13


Integrated and compact system by Baxi for centralized, commercial installations and buildings Baxi has developed cabinets where Luna HT boilers can be installed to have high performance (efficiency up to 109,8%) and low pollutant emissions. The range of Baxi cabinets allows solutions up to 3 doors, from 45 kW (1 cabinet with 2 doors 1x45 kW) to 600 kW ( 2 cabinets with 3 doors 3x100 kW). They are ideal for centralized, commercial applications and buildings. It is possible to integrate them with the Baxi wide range of heat-boxes, LUNA SAT.

Dual flue terminal

Hydraulic separator (not included). It is made of: - frame - pipes - separator

Condensing trap

Return manifold

Eletric box (not included)

Holes for handling Flow manifold

14

Cabinet

Manifold (flow/return/gas)


High efficiency condensing systems

Power HT 45-150 kW

Technical pages 23-31 35-39

40

41-43

• Stainless steel double chamber exchanger: high output in compact size, reliability and long life • Digital control panel “advanced CPS system” with push buttons and wide LCD display with text and symbols • Complete range of temperature regulation accessories • Minimal weight and size • Complete range of accessories for single and cascade installations

Outputs from 45 to 150 kW

Hydraulic system Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue exchanger System to prevent pump sticking operating every 24 hours

Thermoregulation system Remote controller and climatic regulator (supplied as optional) Built-in weather compensation function (outdoor sensor supplied as optional) Mixed zones systems (low and high temperature) installation option Cascade system installation option NTC sensor for DHW cylinder control option

Control system Central heating and indirect cylinder timer Hydraulic pressure switch to prevent boiler operating in event of low water Full electronic anti-frost device Electronic thermometer Central heating pressure gauge

1.450 Product code

WHS

1.650

1.850

1.1000

1.1150

1.1200

1.1500

43104560 43106560 43108560 43110060 43111260 43112060 43115060

Maximum heating heat input

kW

46,4

67

87,2

102,7

115

123,2

154

Maximum heating heat output 80/60°C

kW

45

65

85

100

112

120

150

Maximum heating heat output 50/30°C

kW

48,7

70,3

91,6

107,8

121,1

129,7

162

Minimum heat output 80/60°C

kW

11,8

13,4

32,2

35,8

39

39

40,4

Minimum heat output 50/30°C

kW

12,8

14,5

34,9

38,8

42,1

42,1

43,7

Energetic efficiency 92/42/CEE

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,3

97,3

97,5

97,4

97,4

97,4

97,4

Nominal efficiency 50/30°C

%

105,2

105,3

105,1

105

105,3

105,3

105,2

Efficiency at 30%

%

107,6

107,6

107,3

107,4

107,5

107,5

107,2

5

5

5

5

5

5

5 -5

NOx class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

-5

-5

Safety valve intervention pressure

bar

3

3

3

3

3

3

3

Heating system max pressure

bar

4

4

4

4

4

4

4

Regulation of water temperature in heating circuit

°C

25/80

25/80

25/80

25/80

25/80

25/80

25/80

Primary circuit water flow (∆T=20°C)

l/h

1.935

2.795

3.700

4.300

4.800

5.200

6.500

l

5,1

6,5

13,7

21

23,3

23,3

25,3

ø mm

80

80

100

100

100

100

100

Water content Flue tube

m

30

20

20

20

20

20

20

Maximum flue mass flow rate

Flue ducts max length

kg/s

0,022

0,031

0,041

0,049

0,054

0,059

0,073

Minimum flue mass flow rate

kg/s

0,006

0,007

0,016

0,018

0,019

0,019

0,02

Maximum flue temperature

°C

72

73

78

80

72

77

75

Dimensions (h x w x d)

mm

850x450x621

850x450x693

850x450x801

850x450x871

850x450x1024

850x450x1024

850x450x1132

kg

60

68

75

83

95

95

103

128

135

235

Net weight Gas type Power consumption

Nat. gas/LPG W

90

110

100

160

15


Technical pages 25-31 37-38

43

Power HT 230-320 kW • Aluminium-Silicon exchanger with glass wool insulation: high efficiency and reliability • High modulation ratio (1÷6) • Digital control panel with knob, buttons and wide backlighted LCD display with text and symbols • Easy to transport and to install • Quiet operation

Outputs from 230 to 320 kW

Hydraulic system Hydraulic connections on the rear side Sticking pump check system Flow and return NTC sensors Premixed low-emissions burner

Thermoregulation system Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (high and low temperatures) installation option Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the control panel

Control system Full electronic anti-frost device Electronic thermometer Flow over-temperature thermostat

Power HT 1.230

Power HT 1.280

Power HT 1.320

Product code

LSX

411230600 .

411280600 .

411320600 .

Nominal heat output

kW

215,0

260,0

300,0

Maximum heating heat output 80/60°C

kW

210,1

254,5

294,0

Maximum heating heat output 50/30°C

kW

229,8

278,1

321,3

Minimum heat output 80/60°C

kW

33,5

40,2

45,9

Minimum heat output 50/30°C

kW

37,4

44,9

51,4

´´´´

´´´´

´´´´

Average efficiency (DIN 4702-T8)

%

109,6

109,7

109,7

Nominal efficiency 80/60°C

%

97,9

98,0

98,0

Nominal efficiency 50/30°C

%

106,9

107,0

107,1

Efficiency at 30%

%

105,4

105,6

105,7

5

5

5

Energetic efficiency 92/42/CEE

NOx Class (EN 483) Minimum working temperature

°C

-5

-5

-5

Heating system max pressure

bar

6

6

6

Water content

lt

38

45

53

Flue ducts max length

m

60 (Ø200)

60 (Ø200)

60 (Ø200)

Maximum flue mass flow rate

kg/s

0,097

0,118

0,136

Minimum flue mass flow rate

kg/s

0,016

0,019

0,021

Maximum flue temperature

°C

61

60

60

Dimensions (h x w x d)*

mm

1458x692x1231

1458x692x1324

1458x692x1417

Net weight

kg

285

314

344

Gas type Power consumption (*) Flue ducts and hydraulic pipes included

16

Natural Gas / LPG W

330

350

410


High efficiency condensing systems Info Tech pages 44-45

Luna Sat-Heating only models

RC: KSV 71413111 RC-MB: KSV 71413121

R/1: KSV 71411151 R/1-MB: KSV 71411541

RP/1: KSV 71411161 RP/1-MB: KSV 71411551

R2Z: KSV 71410101 R2Z-MB: KSV 71411901

RH: KSV 71411321 RH-MB: KSV 71411591

RPH: KSV 71411331 RPH-MB: KSV 71411601

RPB: KSV 71411171 RPB-MB: KSV 71411581

RPE: KSV 71411911 RPE-MB: KSV 71411921

RH1: KSV 71411811 RH1-MB: KSV 71411851

RPEH: KSV 71412451 RPEH-MB: KSV 71412461

RHG1: KSV 71412361 R2H: KSV 71412041 RHG1-MB: KSV 71412371 R2H-MB: KSV 71412051

RC

R/1

RP/1

R2Z

RH

RPH

RPB

RPE

RPEH

RH1

RHG1

R2H**

Models with pump

-

-

-

-

-

-

Models with 2nd zone

-

-

-

-

-

-

-

-

-

-

-

-

-

-

25/80

-

-

-

25/80

-

-

-

-

Heating temperature regulation with high climatic curve

°C

Heating circuit maximum pressure

bar

4

4

4

4

4

4

4

4

4

4

4

4

I

0,5

1,5

2

3,5

1,5

2

2

2

2

1,5

2

1,5

Power supply voltage

V

230

230

230

230

230

230

230

230

230

230

230

230

Power supply frequency

Hz

50

50

50

50

50

50

50

50

50

50

50

50

Power consumption

W

15

15

110

210

15

110

110

110

110

15

15

15

Width of the case

mm

450

600

600

800

650

600*

600

600

600

400*

500

800

Height of the case

mm

450

650

650

750

650

716*

650

650

850

600*

850

750

Depth of the case

mm

110

150

150

150

150

150*

150

150

150

200*

150

150

Net weight

Kg

3,2

11

13

22

11

13

12

13,50

14

9

13

9

Maximum temperature of the warm fluid (inlet)

°C

90

90

90

90

90

90

90

90

90

90

90

90

Feed flow (inlet)

l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

Flow-losses

kPa

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

Water contents

(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps (**) For heating and cooling

17


Info Tech pages 44-45

Luna Sat-Heating and DHW production models

RS: KSV 71410081 RS-MB: KSV 71411561

RSP: KSV 71410091 RSP-MB: KSV 71411571

RS2Z: KSV 71410111

RA2Z: KSV 71410781

RA: KSV 71410771

R60WH-MB KSV 71413071

RST-MB: KSV 71413971

RS

RSP

RS2Z

RA

R60WH

RA2Z

RST

DHW production

Models with pump

-

-

Models with 2nd zone

-

-

-

-

-

Heating temperature regulation with high climatic curve

°C

25/80

25/80

25/80

25/80

25/80

25/80

25/80

DHW regulation

°C

30/60

30/60

30/60

30/65

30/65

30/65

30/60

DHW production with ∆T=35°C and inlet water temperature 75°C

l/m

14,3

14,3

14,3

14,3

14,3

14,3

14,3

Heating circuit maximum pressure

bar

4

4

4

4

4

4

4

DHW circuit maximum pressure

bar

8

8

8

8

8

8

8

DHW circuit minimum pressure

0,2

bar

0,2

0,2

0,2

0,2

0,2

0,2

Water contents

l

2

2,5

4

2

5

4

2

Power supply voltage

V

230

230

230

230

230

230

230

Power supply frequency

Hz

50

50

50

50

50

50

50

Power consumption

W

15

110

210

150

110

210

15

Width of the case

mm

600

600

800

600

910

800

600

Height of the case

mm

650

650

750

650

450

750

600

Depth of the case

mm

150

150

150

150

473

150

150

Net weight

Kg

16

18

28

16

38

25

16

Maximum temperature of the warm fluid (inlet)

°C

90

90

90

90

90

90

90

Feed flow (inlet)

l/h

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

Flow-losses

kPa

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

18


High efficiency condensing systems

Technical Section

Technical drawings Graphs Flue systems

20

Flue pipes accessories

32

Hydraulic accessories

39

Thermoregulation accessories

41

Other accessories

44

Products technical data

46

19


High efficiency condensing system Luna Platinum 1.12-1.18-1.24-1.32 140,5

131min.

177

M.B.

760

450

S.C. M.R. M.B. GAS E.S. R.R.

Condensing trap that can be installed on a Ø 21 pipe Heating system flow G 3/4” Storage tank flow G 3/4” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

6 5,5 5 4,5 4 3,5 3 2,5 2 1,5 1

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

FLOW RATE/HEAD CURVE

Flues temperature %

HEAD

345

MAX MIN

200

400

800

600

1000

1200

Efficiency of the boiler %

30% load

108 107 106 105 104 103 102 101 100 99 98 97

30% load

40

45

40

45

50

Return temperature of the system °C

100% load

35

35

1400

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

20

100% load

30 0

FLOW RATE (l/h)

30

75 70 65 60 55 50 45 40 35 30

50

Return temperature of the system °C

55

60

55

60


Technical drawings - graphs - flue systems

High efficiency condensing system Luna Duo-tec MP

Luna Duo-tec MP 1.90-1.110

1.50-1.60-1.60 450 225

(A)

140

223 952

229

763

225

600 354,5

584 245,5

112

(A) 377 mm Mod. 1.50-1.60 505 mm Mod. 1.70 Coaxial flue system ø 80/125 Dual flue system ø 80 GAS M.R.

S.C

GAS

M.R.

R.R.

R.R. S.C.

Coaxial flue system Dual flue system

Entrata Gas inlet G ¾” Heating system flow (G1”) with cylinder connection option Heating system return (G1”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe

ø 110/160 ø 110 GAS M.R.

S.C

GAS

M.R.

R.R.

Gas inlet G 1” Heating system flow (G1-G1/2”) with cylinder connection option Heating system return (G1-1/2”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe

R.R.

S.C.

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.70

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.90

HEAD (mH2O)

HEAD (mH2O)

HEAD (mH2O)

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.50 - 1.60

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.110

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

108 107 106 105 104 103 102 101 100 99 98 97

30% load 100% load

30

FLOW RATE (l/h)

FLOW RATE (l/h)

35

40

45

50

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

Flues temperature %

Efficiency of the boiler %

FLOW RATE (l/h)

HEAD (mH2O)

FLOW RATE (l/h)

55

Return temperature of the system °C

60

75 70 65 60 55 50 45 40 35 30

100% load

30% load

30

35

40

45

50

55

60

Return temperature of the system °C

21


High efficiency condensing system GMC

2 door cabinet dimensions (mm) Modules

W

H

D

2 doors

1600

1900

800

3 door cabinet dimensions (mm) Modules

W

H

D

3 doors

2400

1900

800

1900

190

Ă˜149

228

290

194

124

417

2400

309

Luna HT Residential 45-55-65 kW 800

800

277,5

22

160 800

331

Luna HT Residential 85-100 kW 355

454,5 182,5

445

77

800

800

345,5


Technical drawings - graphs - flue systems

High efficiency condensing system Power HT 45-150 kW Placement RVA

Power HT

FLOW RATE/HEAD CURVE

Depth (A) mm

HEAD (mH2O)

Power HT To allow an easy access for the boiler maintenance, the minimum recommended distance must be observed

FLOW RATE (l/h)

45 cm

45 cm/ 2 cm

EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS

45 cm/ 2 cm

FLOW RATE (l/h) EXCHANGER PRESSURE LOSS EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS

FLOW RATE (l/h)

FLOW RATE (l/h)

23


High efficiency condensing system

186,5

936,5

136,5

800

Power HT 45-150 kW

20 * 450

450

20* 450

436,5

(*) - The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used. Flow/return manifolds squared 100x100 with flanges DN80 PN6 24


Technical drawings - graphs - flue systems

High efficiency condensing system Power HT 230-320 kW

Flow

Flange

Return Flange

Power HT

1.230

1.280 1.320

Depth (A) mm

1.269

1.362 1.452

HEAT PRODUCTION ACCORDING TO THE OUTDOOR TEMPERATURE T

H 80 R 0 23 .2 E 1. T 1 OW T H RH P ER E W OW PO P

Characteristic curve

Hea

ting

flow

Heati

Dew point = 54째C

ng re

turn

100

Outdoor temperature 째C 10

EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT

1 1

0

1

FLOW RATE [m3/h]

100

Efficiency%

WATER SIDE RESISTANCE (mbar)

1000

0

32

1.

Heating water temperature

EXCHANGER PERSSURE LOSSES

Output %

25


High efficiency condensing system Power HT 230-320 kW

@

A

1 Remove lower rear wall (2) of the Power HT

Side supply air connection (A)

Rear supply air connection (B)

2 Remove the gas connection leading upward

1 Remove lower rear wall (3)

1 Remove lower rear wall (2)

2 Remove the covering panel (2)

2 Take out cover plate (3)

3 Mount the bend of the intake pipe (1)

3 Mount straight intake pipe

4 Turn intake pipe elbow into the side position (1)

4 Mount lower rear wall (2)

and insert a 87°bend (1) 3 Turn 87°bend (1) in the desired position (side or towards the rear) 4 Remove either the rear cover plate (3) or the

5 Mount lower rear wall (3)

side cover plate (4) 5 Mount lower rear wall (2)

Max lengths for the flue pipes with room air dependent working (type B installation)

Model

Power HT 1.230

Power HT 1.280

Power HT 1.320

Flue pipe - ø

mm

200

200

200

Max L. pipe inc. 87° bend

mm

60

60

60

These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m 1 piece 45° bend: 2 m 1 piece 15° bend: 1 m

26


Technical drawings - graphs - flue systems

Coaxial flue system Luna Platinum

GSPOUBM WJFX

TJEF WJFX

Example of installation with horizontal flue system Ă˜ 60/100 and Ă˜ 80/125

Tubes maximum length (m)

Installation examples with LAS chimney Ă˜ 60/100 and Ă˜ 80/125

Ă˜ 60/100

Ă˜ 80/125

10

25

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

1

0,5

Installation example with vertical coaxial flue ducts Ă˜ 60/100 and Ă˜ 80/125

Vertical chimney terminal for coaxial flue system

ø

ø

ø ø

,)( 7FSUJDBM DIJNOFZ UFSNJOBM GPS DPBYJBM ðVF TZTUFN ø

,)( 3FEVDUJPO GSPN ø UP ø

27


Dual flue system Luna Platinum

GSPOUBM WJFX

TJEF WJFX

Example of installation with vertical dual flue system

GSPOUBM WJFX

TJEF WJFX

Installation example with horizontal dual flue ducts

Intake pipe maximum length: 15 m.

Vertical chimney terminal for dual flue system

ø

ø

,)( 7FSUJDBM DIJNOFZ UFSNJOBM ø

28

,)( %VBM ðVF QJQFT BEBQUFS GPS DPBYJBM DIJNOFZ ø UP ø


Technical drawings - graphs - flue systems

Flue system – Coaxial flue system Luna Duo-tec MP Type of duct

Tubes maximum length (m)

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

Ø chimney terminal (mm)

Ø external duct

Coaxial Ø 110/160 mm

10 m

1m

0,5 m

163 mm

160 mm

Vertical dual flue system

15 m

0,5 m

0,25 m

163 mm

110 mm

Coaxial Ø 85/125 mm

10 m

1m

0,5 m

133 mm

125 mm

Vertical dual flue system

15 m

0,5 m

0,25 m

133 mm

80 mm

Horizontal dual flue system*

60 m

0,5 m

0,25 m

-

80 mm

* intake pipe maximum length: 15 m.

COAXIAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80/125 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110/160 mm

DUAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80+80 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110+110 mm

Luna Duo-tec MP – Coaxial flue system Installation example with coaxial flue ducts Ø 80/125 (mod. 1.50 - 1.60 - 1.70) and Ø 110/160 (mod. 1.90 - 1.110)

29


Dual flue system Luna Duo-tec MP 1.50 - 1.70

Luna Duo-tec MP 1.90 - 1.110

Installation example with horizontal dual flue ducts

Intake pipe maximum length: 15 m

Example of installation with vertical dual flue system

30


Technical drawings - graphs - flue systems

Flue system Power HT (45-150 kW) – Flue pipe

Model

Tubes maximum length (m)

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

30 20 20 20 20 20 20

1 1 1 1 1 1 1

0,5 0,5 0,5 0,5 0,5 0,5 0,5

HT 1.450 HT 1.650 HT 1.850 HT 1.1000 HT 1.1150 HT 1.1200 HT 1.1500

Power HT (230-320 kW) – Flue/Intake pipes

flow flange DN 65

return flange DN 65

Ø flue pipe Tube maximum length including 1 87° bend (m)

Power HT 1.230

Power HT 1.280

Power HT 1.320

mm

200

200

200

mm

60

60

60

These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m

31


Accessories for high efficiency condensing systems Flue Systems - Coaxial flue - Dual flue - Flue accessories for cascade installation - Flexible ducting system

32

33 34 38 39

Hydraulic accessories

39

Thermoregulation accessories

41

Accessories available as option for Luna SAT

44


Flue pipe accessories Coaxial flue system: Luna Platinum - Luna Duo-Tec MP 50-70 kW Description

Code

PP coaxial flue pipe with terminal Ø 80/125 L=1000 mm supplied with wind proof terminal and sealing collar

KHG 714088910 •

PP coaxial flue pipe extension Ø 80/125 L=1000 mm

KHG 714088511 •

PP coaxial flue pipe extension Ø 80/125 L=500 mm

KHG 714088610 •

PP coaxial 90° bend - Ø 80/125

KHG 714088711 •

PP coaxial 45° bend - Ø 80/125

KHG 714088811 •

Coaxial flue system: Luna Platinum Description

Code

PP coaxial flue pipes with terminal Ø 60/100 L=750 mm supplied with windproof terminal and sealing collar

KHG 714059613

PP coaxial flue pipe extension Ø 60/100 L=1000 mm

KHG 714059516

PP coaxial flue pipe extension Ø 60/100 L=500 mm

KHG 714119810

PP coaxial 90° bend - Ø 60/100

KHG 714059717 •

PP coaxial 45° bend - Ø 60/100

KHG 714059817 •

Internal sealing collar Ø 100

KHG 714017710 •

PP vertical chimney terminal Ø 80/125(1)

KHG 714093510 •

PP reduction from Ø 80/125 to 60/100

KHG 714093910 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125

KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°

KHG 714093710 •

(1)

+KHG 714093910 •

Coaxial flue system: Luna Duo-Tec MP 50-70 kW Description

Code

PP vertical chimney terminal Ø 80/125

KHG 714093510 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125

KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°

KHG 714093710 •

33


Flue pipe accessories Coaxial flue system: Luna Duo-Tec MP 90-110 kW Description

Code

PP coaxial flue pipe extension Ø 110/160 L=1000 mm

KUG 714133810 •

PP coaxial flue pipe extension Ø 110/160 L=500 mm

KUG 714133710 •

PP coaxial 90° bend - Ø 110/160

KUG 714133610 •

PP coaxial 45° bend - Ø 110/160

KUG 714133510 •

PP vertical chimney terminal Ø 110/160

KUG 714133410 •

PP horizontal coaxial chimney Ø 110/160

KUG 714133310 •

Flat roof tile to be used with a vertical chimney terminal Ø 110/160

KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminal Ø 110/160; it is adjustable from 15° to 45°

KHG 714104910 •

Dual flue system: Luna Platinum

34

Description

Code

Orientable dual flue system

710268902 •

PP dual flue system Ø 80 it includes: flue reduction, intake connection

KHG 714059113 •

PP vertical flue system B23 type installation

KHG 714111011 •

PP pipe extension Ø 80 L=1000 mm

KHG 714059411 •

PP pipe extension Ø 80 L=500 mm

KHG 714059910 •

PP pipe extension Ø 80 L=250 mm

710718301 •

PP 90° bend Ø 80

KHG 714059211 •

PP 45° bend Ø 80

KHG 714059311 •

Dual flue terminal Ø 80

KHG 714010410 •

PP reduction from Ø 80 to Ø 60

KHG 714075610 •

PP pipe extension Ø 60 L=1000 mm

KHG 714075310 •

PP pipe extension Ø 60 L=500 mm

KHG 714075210 •

PP 90° bend Ø 60

KHG 714075410 •

PP 45° bend Ø 60

KHG 714075510 •


Flue pipe accessories Dual flue system: Luna Platinum Description

Code

Dual flue terminal Ø 60

KHG 714037210 •

Pipe Ø 80 centring kit (pack of 5)

KHG 714037411 •

Clamp centring kit Ø 80

KHG 714106110 •

Pipe Ø 60 centring kit (pack of 5)

KHG 714051510 •

Pipe Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

External sealing collar Ø 80

KHG 714018411 •

Coaxial vertical chimney terminal Ø 80/125(1)

KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125

KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal

KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

KHG 714093710 •

(1)

+KHG 714093810 •

Dual flue system: Luna Duo-Tec MP 50-70 kW - floor standing boilers 45-65 kW Description

Code

PP pipe extension Ø 80 L=1000 mm

KHG 714059411 •

PP pipe extension Ø 80 L=500 mm

KHG 714059910 •

PP pipe extension Ø 80 L=250 mm

710718301 •

PP 90° bend Ø 80

KHG 714059211 •

PP 45° bend Ø 80

KHG 714059311 •

Pipe Ø 80 centring kit (pack of 5)

KHG 714037411 •

Clamp centring kit Ø 80

KHG 714106110 •

Pipe Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

External sealing collar Ø 80

KHG 714018411 •

Flue terminal Ø 80

LSD 790000150 •

Dual flue terminal Ø 80

KHG 714010410 •

35


Flue pipe accessories Dual flue system: Luna Duo-Tec MP 50-70 kW Description

Code

PP dual flue system Ø 80 it includes: flue reduction, intake connection

KHG 714089010 •

Coaxial vertical chimney terminal 80/125

KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125

KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal

KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

KHG 714093710 •

Dual flue system: Luna Duo-Tec MP 90-110 kW Description

Code

PP dual flue kit Ø 110/110

710631401 •

Dual flue system: Luna Duo-Tec MP 90-110 kW - floor standing boilers 85-150 kW Description

Code

PP pipe extension Ø 110 L=1000 mm

KUG 714133210 •

PP pipe extension Ø 110 L=500 mm

KUG 714133110 •

PP pipe extension Ø 110 L=250mm

710718501 •

PP 90° bend Ø 110

KUG 714133010 •

PP 45° bend Ø 110

KUG 714132910 •

PP reduction kit from Ø 110 to Ø 100(1)

KHW 714096910 •

PP vertical chimney terminal Ø 110

KUG 714132810 •

PP horizontal chimney terminal Ø 110

KUG 714132710 •

Flat roof tile to be used with a vertical chimney terminal Ø 110/160

KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminal 110/160; it is adjustable from 15° to 45°

KHG 714104910 •

(1)

36

only for floor standing boilers 85-150 kW


Flue pipe accessories Dual flue system: floor standing boilers 230-320 kW Descrizione

Codice

Extension pipe Ø 200 L=500 mm

LXO 000971911 •

Extension pipe Ø 200 L=1000 mm

LXO 000971928 •

Extension pipe Ø 200 L=2000 mm

LXO 000971935 •

87° bend Ø 200

LXO 000971942 •

45° bend Ø 200

LXO 000971959 •

Spacer Ø 200

LXO 000971973 •

Pitched roof tile Ø 200

LXO 000971997 •

SAS flue discharge 200-1B

LXO 000688673 •

SAS flue discharge 200-2B

LXO 000688680 •

Air grid Ø 200

LXO 000971980 •

87° bend Ø 200 with inspection

LXO 000971904 •

Up right duct with inspection hole

LXO 000971898 •

SAS vertical chimney terminal Ø 200

LXO 000989527 •

Passing roof Ø 200

LXO 000989497 •

Comburent air filter

LXO 000692656 •

Room air indipendent working (WAS 200)

LXO 000971881 •

37


Flue pipe accessories Flue accessories for cascade installation (for all boilers model, except for floor standing boilers 230-320 kW) Description

Code

PP flue pipe kit Ø 160 for two boilers

710715201 •

PP flue pipe kit Ø 200 for two boilers

710715601 •

PP flue pipe kit Ø160 for the third boiler

710716301 •

PP flue pipe kit Ø200 for the third boiler

710716401 •

PP 87° bend Ø160

KHW 714097810 •

PP 87° bend Ø200

KHW 714098210 •

PP pipe extension Ø160 L=1000 mm

KHW 714097710 •

PP pipe extension Ø200 L=1000 mm

KHW 714098110 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 50-70 kW - floor standing boilers 45-65 kW Description

Code

PP flue pipe kit for two boilers Ø 125

710716801 •

PP flue pipe kit Ø125 for the third boiler

710717701 •

PP shutter kit Ø 110/80 with condensing trap

710682001 •

PP 90° bend Ø 125

KHG 714094410 •

PP 45° bend Ø 125 (pack of 2)

KHG 714094510 •

PP pipe extension Ø 125 L=1000

KHG 714094610 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 90-110 kW - floor standing boilers 85-150 kW Description

Code

PP shutter kit Ø 110/110 with condensing trap

710682101 •

Flue accessories for cascade installation: floor standing boilers 85-150 kW Description

Code

PP reduction kit from Ø 110 to Ø 100

KHW 714096910 •

Flue accessories for cascade installation: floor standing boilers 230-320 kW

38

Description

Code

Manifold for 2 boilers in cascade 250 mm

LXO 000691444 •


Flue pipe accessories Flexible ducting system accessories: wall hung - floor standing boilers 45-65 kW Description

Code

PP flexible pipe Ø 80 L= 1,5 m

KHG 714105710 •

PP flexible pipe Ø 80 L= 20 m

KHG 714105810 •

PP tee joint Ø 80 with supporting bracket and condensate drainings

KHG 714105910 •

PP 90° bend Ø 80 with supporting bracket

KHG 714106010 •

Flexible centring kit Ø 80 (pack of 3)

KHG 714106210 •

Triple lips gaskets kit Ø 80 (pack of 5)

KHG 714111210 •

Hydraulic accessories: Luna Duo-tec MP 50-110 kW Description

Code

Manifold for separator 8,5 m3/h

710686501 •

Manifold ins. kit for separator 8,5 m3/h

710687901 •

Flanges and gaskets kit for separator 8,5 m3/h

LSD 790000440 •

Hydraulic separator HS 8.5 of 8,5 m³/h - 2” threaded connectors

LSD 790000310 •

Manifold for separator 18 m3/h

710687501 •

Manifold ins. kit for separator 18 m3/h

710688901 •

Flanges and gaskets kit for separator 18 m3/h

LSD 790000430 •

Hydraulic separator HS 18 of 18 m³/h - Ø 65 flanged connectors

LSD 790000320 •

Manifold for separator 28 m3/h

710687601 •

Manifold ins. kit for separator 28 m3/h

710689201 •

Flanges and gaskets kit for separator 28 m3/h

LSD 790000420 •

Hydraulic separator HS 28 of 28 m³/h - Ø 80 flanged connectors

LSD 790000330 •

Hydraulic separator HS 56 of 56 m³/h - Ø 100 flanged connectors

LSD 790000340 •

Neutralizer kit for wall hung boilers up to 350 kW

KHG 714125710 •

Recharge for neutralizer kit for wall-hung boilers up to 350 kW

KHG 714135410 •

39


Hydraulic accessories: Luna Platinum Description

Code

Manifold pipes for 2 Platinum boilers in cascade

KHG 714117111 •

Manifold pipes for the 3rd Platinum boiler in cascade

KHG 714117211 •

Neutralizer kit for wall hung boilers up to 100 kW

KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW

KHG 714135310 •

Heating systems taps and connection pipes

710931401 •

Hydraulic accessories: Luna Duo-tec MP Description

Code

Safety device ISPESL (available as optional - compulsory accessory only for Italian market)

KHW 714098411 •

Neutralizer kit for wall hung boilers up to 100 kW

KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW

KHG 714135310 •

Hydraulic accessories: floor standing boilers 45-150 kW

40

Description

Code

Safety device ISPESL (available as optional - compulsory accessory only for Italian market)

KHW 714098411 •

Manifold pipes single boiler/last boiler

KHW 714104210

Boiler-manifold pipe hydraulic connection

KHW 714104311

Manifold pipes boilers in cascade (45 cm between the boilers)

KHW 714099010 •

Manifold pipes boilers in cascade (2 cm between the boilers)

KHW 714103611 •

Hydraulic connection for 2nd pump

KHW 714098611 •


Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum - Luna Duo-tec MP floor standing boilers 45-150 kW Description

Code

Mixing valve motor

KHG 714078511 •

Mixing valve G1”

KHG 714078310 •

Mixing valve G1/2”

KHG 714078610 •

Mixing valve G3/4”

KHG 714078710 •

Flow/return sensor for controller for boilers in cascade and mixing system

KHG 714078810 •

Flow sensor for clip-in module

KHG 714078910 •

Hot water temperature sensor

KHG 714076810 •

Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description

Code

Outdoor sensor THINK

710487301 •

Outdoor sensor THINK (wireless)*

710302701 •

Interface kit for remote control THINK - 3 leds

710234002 •

Interface kit for remote control THINK - 5 leds wireless

710244102 •

Wireless aerial THINK

710234301 •

Room thermostat THINK

710106105 •

Room thermostat (wireless) THINK*

710304404 •

Room thermostat with timer THINK

710298005 •

Room thermostat with timer THINK – wireless*

710297904 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 •) or the wireless aerial THINK (710234301 •)

41


Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description

Code

Programmable clip-in module THINK

710034502 •

Flow sensor for clip-in module THINK

KHG 714078910 •

Programmable external module THINK

710503704 •

Hot water temperature sensor

KHG 714076810 •

Interface kit for boilers in cascade THINK

710440802 •

Climate controller kit for mixing zones THINK

710519902 •

Sensor for solar controller

LNC 710000040 •

Accessories for the thermoregulation, programming, setting and digital control - Luna Duo-tec MP Description

Code

Outdoor sensor THINK

710487301 •

Outdoor sensor THINK (wireless)*

710302701 •

Wireless aerial THINK

710234301 •

Programmable clip-in module THINK

710034502 •

Programmable external module THINK

710503704 •

Hot water temperature sensor

KHG 714076810 •

Remote control THINK

710244202 •

Remote control THINK (wireless)

710244302 •

Climate controller kit for mixing zones THINK

710519902 •

Interface kit for boilers in cascade THINK

710440802 •

Sensor for solar controller

LNC 710000040 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 •) or the wireless aerial THINK (710234301 •)

42


Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 45-150 kW Description

Code

Outdoor sensor

KHG 714072811 •

Remote controller and climatic regulator

KHG 714072612 •

Boiler interface for mixing systems with two different temperatures zones

KHG 714077913 •

Bus interface for climatic regulators for boilers in cascade

KHG 714078013 •

Boiler control interface 0-10 V

KHG 714107612 •

Temperature regulator for mixing systems, it includes a temperature sensor

KHG 714078112 •

Cascade controller, it includes a temperature sensor

KHG 714078212 •

Room sensor: it can be installed only with climatic regulator for mixing system

KHG 714078410 •

Installation box for RVA controllers

KHG 714096610 •

Hot water temperature sensor for climatic regulator for boilers in cascade

KHG 714079010 •

Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 230-320 kW Description

Code

Outdoor sensor THINK

710487301 •

Interface kit for boilers in cascade

710440802 •

External tank sensor L=2 m

LSX 710000010 •

External tank sensor L=6 m

LSX 710000020 •

Accessory for managing mixing systems or solar panels

LSX 710000030 •

Climate controller kit for mixing zones THINK

710519902 •

LPG conversion kit: Luna Duo-tec MP Description

Code

LPG conversion kit for LUNA DUO-TEC MP 1.50

710718603 •

LPG conversion kit for LUNA DUO-TEC MP 1.60

710718702 •

LPG conversion kit for LUNA DUO-TEC MP 1.70

710718802 •

LPG conversion kit for LUNA DUO-TEC MP 1.90

710718902 •

LPG conversion kit for LUNA DUO-TEC MP 1.110

710719002 •

43


Accessories available as option Luna SAT WIRELESS data transmission

Code

Network node Network node with gateway Network node with gateway for transmission via GSM Remote reader device Software ACS 26 Connecting cable PC-network node for network note with gateway Wireless impulse adaptor AEW36.2

KSV 714102711 • KSV 714103011 • KSV 714102811 • KSV 714102911 • KSV 714108611 • KSV 714116110 • KSV 714117710 •

M-BUS data transmission

Code

Impulse adaptor AEW 310.2 M-BUS Connection cable heat meter M-BUS M-BUS central unit made of 250 loads M-BUS central unit made of 120 loads M-BUS central unit made of 60 loads M-BUS central unit made of 20 loads

KSV 714116210 • KSV 714116310 • KSV 714136910 • KSV 714137010 • KSV 714137110 • KSV 714137210 •

WIRELESS control

Code

First flow meter - mod. R/1-RP/1-R2Z - RPE - RPB First flow meter - mod. RS-RSP-RS2Z Second flow meter - mod. RP/1 Second flow meter - mod. R/1-R2Z - RPE - RPB Flow meter - mod. RA-RA2Z First or second flow meter - mod. RH -RH1- R2H First or second flow meter - mod. RPH First or second flow meter RHG1 1’’ First or second flow meter RHG1 3/4’’ Flow meter - Luna Sat RC

KSV 714102511 • KSV 714102611 • KSV 714106312 • KSV 714110111 • KSV 714110011 • KSV 714114511 • KSV 714114611 • KSV 714124910 • KSV 714125111 • KSV 714131310 •

M-BUS control

Code

First flow meter - mod. R/1-MB, RP/1-MB, R2Z-MB - RPE-MB, RPB - MB First flow meter - mod. RS-MB, RSP-MB, RS2Z-MB First or second flow meter - mod. RH-MB, RH1-MB, R2H-MB First or second flow meter - mod. RPH-MB Second flow meter - mod. RP/1-MB Second flow meter - mod. R/1-MB, R2Z-MB - RPE-MB, RPB-MB First or second flow meter RHG1-MB 1’’ First or second flow meter RHG1-MB 3/4’’ M-BUS flow meter - Luna Sat RC-MB

KSV 714116410 • KSV 714116510 • KSV 714116610 • KSV 714116710 • KSV 714118210 • KSV 714118310 • KSV 714125010 • KSV 714125210 • KSV 714134310 •

Thermoregulation

Code

Outdoor sensor Room thermostat (RT) Remote control and chronostat (mod. R2Z, RS, RSP, RS2Z, RA, RA2Z, RPE, RPEH - wireless and M-BUS) Digital chronostat (mod. R/1, RP1)

KHG 714072811 • KHG 714062810 • KSV 714109511 • KHG 714086711 •

44


Accessories available as option Luna SAT Other accessories

Code

Heat meter UH50 G1 ¼’’ Heat meter UH50 G2’’ Wireless interface UH50 for ultrasonic heat-meter

KSV 714117810 • KSV 714117910 • KSV 714121710 •

Well for NTC sensor (½” and ¾”) for UH50 G1 ¼”

KSV 714127310 •

Well for NTC sensor for UHG50 G2”

KSV 714127410 •

M-BUS interface UH50 for ultrasonic heat-meter

KSV 714121810 •

Complete template for Luna Sat RH1 By-pass for Luna Sat RC Heating hydraulic proof for Luna Sat RC

KSV 714122310 • KSV 714136310 • KSV 714136410 •

Sanitary hydraulic proof for Luna Sat RC

KSV 714136510 •

2L Sanitary expansion vessel for Luna Sat R60WH

soon available

GSM modem for DIN frame

KSV 714140810 •

Equipment (for all wireless/M-BUS models)

Code

Hydraulic equipment for Luna Sat heating only models R/1, RP/1, RH, RH1, RPH, RPB, RPE, R2H (x2), RPEH Hydraulic equipment for Luna Sat heating and DHW production model RS, RSP

KSV 714120911 • KSV 714121011 •

Hydraulic equipment for Luna Sat models R2Z, RA, RA2Z

KSV 714121110 •

Hydraulic equipment for Luna Sat heating / DHW production model RS2Z Hydraulic equipment for 2 flow meters for Luna Sat R/1, RP/1, RPB, RPE models Hydraulic equipment for 2 flow meters for Luna Sat RH, RPH, R2H. RPEH models

KSV 714121210 • KSV 714121310 • KSV 714121410 •

Mounting accessories

Code

Single zone case 2 zones case

KSV 714101211 • KSV 714101311 •

Case for RH 650x650 mm

KSV 714117011 •

Case for R2H

KSV 714120610 •

Case for RHG1

KSV 714124010 •

Case for RPH - RPEH Case for RC Case for RST

KSV 714124310 • KSV 714131010 • KSV 714141210 •

Cylinder

Code

Luna SAT B60 cylinder

KSV 71410841

45


Products technical data High efficiency condensing gas boilers

46

47


17,4

24,7

33

46,3

56,6

66,9

87,4

104,9

34,8

46,4

46,4

56,7

67

87,2

105

46,4

67

87,2

102,7

115

123,2

154

215

260

300

LUNA PLATINUM 1.18

LUNA PLATINUM 1.24

LUNA PLATINUM 1.32

LUNA DUO-TEC MP 1.50

LUNA DUO-TEC MP 1.60

LUNA DUO-TEC MP 1.70

LUNA DUO-TEC MP 1.90

LUNA DUO-TEC MP 1.110

LUNA HT 1.350

LUNA HT 1.450

LUNA HT 1.450 P

LUNA HT 1.550

LUNA HT 1.650

LUNA HT 1.850

LUNA HT 1.1000

POWER HT 1.450

POWER HT 1.650

POWER HT 1.850

POWER HT 1.1000

POWER HT 1.1150

POWER HT 1.1200

POWER HT 1.1500

POWER HT 1.230

POWER HT 1.280

POWER HT 1.320

kW

48

42

35

41,5

40

40

36,8

33,1

13,8

12,2

29,8

26,4

20

16

15

15

15

11,7

9,7

7,4

6,3

5,1

3,3

2,5

2,1

2,1

kW

12,4

MIN.

MAX.

Heat input

LUNA PLATINUM 1.12

PRODUCT

294

254,5

210,1

150

120

115

100

85

65

45

102

85

65

55

45

45

33,9

102

85

65

55

45

32

24

16,9

12

kW

MAX.

45,9

40,2

33,5

40,4

39

39

35,8

32,2

13,4

11,8

29

25,7

19,3

15,5

14,5

14,5

14,5

11,4

9,4

7,2

6,1

5

3,2

2,4

2

2

97,4

97,4

97,3

97,4

97,4

97,4

97,4

97,5

97,3

97,3

97,4

97,5

97,3

97,4

97,3

97,3

97,3

97,2

97,3

97,2

97,2

97,4

97,6

97,6

97,6

97,7

MIN. average temp. Pn 70°C kW %

Heat output

105,7

105,6

105,4

107,2

107,5

107,5

107,4

107,3

107,6

107,6

107,4

107,3

107,6

107,5

107,6

107,6

107,6

107,4

107,3

107,6

107,6

107,6

107,6

107,6

108

108

%

30%

92/42/EEC

98,1 98,1 98,0 97,8 97,8 97,9 97,8 97,9 97,9 97,9 98,0 97,9 98,1 98,0 97,9 97,9 98,1 98,0 98,0 98,0 98,0 97,9 98,0 98,0

★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★

1,7

1,7

1,7

2,0

2,0

2,0

2,0

1,9

2,1

2,1

2,0

1,9

2,1

2,0

2,1

2,1

2,1

2,2

2,1

2,2

2,2

2,0

1,9

1,9

2,6

2,5

2,5

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,5

0,5

0,5

0,0

0,0

0,0

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

61

61

61

75

77

72

80

78

75

75

74

75

75

78

74

74

72

74

75

76

96

92

80

80

75

9,3

9,3

9,3

8,7

8,7

8,7

8,7

8,7

8,9

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

9,2

9,0

9,0

9,0

9,0

9,0

9,0

9,0

★★★★

1,9

75

98,1

0,1

★★★★

0,5

%

1,8

9,0

CO2

98,2

burner

not working

★★★★

Maximum Output

stars combustion chimney radiating chimney flue number efficiency heat heat heat temp. 92/42/EEC losses losses losses max % % % % °C

Efficiency (Hi)

4,3

4,3

4,3

5,4

5,4

5,4

5,4

5,4

5,0

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

4,5

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

%

O2

26

26

26

34

34

34

34

34

31

34

34

34

34

34

34

34

34

27

30

30

30

30

30

30

30

30

0,136

0,118

0,097

0,073

0,058

0,054

0,049

0,041

0,031

0,022

0,050

0,041

0,032

0,027

0,022

0,022

0,016

0,047

0,040

0,031

0,026

0,021

0,015

0,011

0,008

0,006

57

57

57

58

58

55

57

56

55

55

55

55

55

55

55

55

55

55

55

55

59

58

55

55

55

55

exceeding flue flue air mass temp. and flow/rate max % kg/s °C

Maximum output

9,3

9,3

9,3

8,4

8,4

8,4

8,6

8,6

8,4

8,4

8,4

8,4

8,4

8,4

8,4

8,4

8,4

9,0

8,5

8,5

9,0

8,5

9,0

9,0

9,0

9,0

%

CO2

4,3

4,3

4,3

5,9

5,9

5,9

5,6

5,6

5,9

5,9

5,9

5,9

5,9

5,9

5,9

5,9

5,9

4,8

5,7

5,7

4,8

5,7

4,8

4,8

4,8

4,8

%

O2

Power consumption

26

26

26

39

39

39

36

36

39

39

39

39

39

39

39

39

39

30

38

38

30

38

30

30

30

30

0,021

0,019

0,016

0,020

0,019

0,019

0,018

0,016

0,007

0,006

0,015

0,013

0,010

0,008

0,007

0,007

0,007

0,005

0,005

0,004

0,003

0,002

0,002

0,001

0,001

0,001

410

350

330

235

135

128

160

100

110

900

200

150

125

80

175

75

45

320

275

210

210

190

130

120

110

95

-

-

-

-

-

-

-

-

-

-

-

-

-

-

100

-

-

170

165

125

120

115

75

75

75

75

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

Minimum Output

0085CL0072

0085CL0072

0085CL0072

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085CM0128

0085CM0128

0085CM0128

0085CM0128

0085CM0128

0085CM0140

0085CM0140

0085CM0140

0085CM0140

Nr.

Certificate EEC

Products technical data – High efficiency condensing boilers

47


Quality Environment Safety

Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations

36061 BASSANO DEL GRAPPA (VI) - ITALY Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 03-12 (E)


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.