General catalogue COMMERCIAL AND TECHNICAL INFORMATION Commercial Range
Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the highest technological standards. For over 30 years BAXI SPA has provided a wide range of cutting-edge solutions, anticipating market evolutions and paying attention to customer needs.
How to read this catalogue In this catalogue we show the high efficiency condensing system complete range of BAXI products. On each page, in addition to the product benefits, there is a detailed list of the appliance characteristics, a technical chart, and coloured icons. These icons refer to the specific pages of the technical section of the catalogue where, by segment, the technical drawings and all the specific accessories are represented.
In the technical section you will find:
Dimensional Flue tube technical accessories drawings Graphs Flue systems
2
Hydraulic accessories
Thermoregulation accessories
Other accessories
High efficiency condensing systems
More details and information on the website By accessing to the www.baxi.it, Reserved Area and then to the Tech Area, just after a quick registration it is possible to display and download the following documents:
• Certifications • Fault Finding List • General Catalogues • General informations catalogues of all Baxi products • Instructions Manuals • PCB Service Instructions • Spare Parts Catalogues • Technical Drawings • Technical INFO
Index High efficiency condensing boilers
6
Built-in heat-boxes - Luna Sat
8
Luna Platinum 12 - 32 kW
10
Luna Duo-tec MP 50 - 110 kW
11
Luna HT 45 - 100 kW
12
Cabinets (GMC)
13
Power HT 45 - 150 kW
15
Power HT 230 - 320 kW
16
Luna Sat
17
Technical section
19
3
Condensing technology is the latest face in boiler innovation. By employing pre-mix burner know how, condensing boilers ensure higher performance (efficiency up to 109,8%) thanks to the recovery of all the heat available through combustion without wasting energy into the air, as happens with traditional boilers.
4
High efficiency condensing systems High efficiency installations Baxi condensing systems represent the ideal solution for installations where high outputs are required. The electronics platform of these boilers allows the control of single and cascade installations and a complete range of thermoregulation accessories. It is therefore possible to have high energetic efficiency system ensuring low emissions and meeting any domestic comfort needs, total control, DHW at the right comfort level always in the maximum respect of the environment.
High modulation ratio The new ranges of high efficiency condensing boilers are distinguished by a wider modulation ratio that grants a better efficiency thanks to reduced switch-on/ switch-off of the boiler.
Cutting edge electronics The sophisticated electronics of the high efficiency condensing boilers allows to manage single or cascade installation up to 16 boilers (Luna Duotec MP or Power HT 230-320). It is just needed to connect the relevant accessories to the boiler’s electronics.
Compact weight and dimensions Compact weight and dimensions of Baxi high efficiency condensing systems, guarantee the maximum flexibility and allow their installation also in small heat generator rooms. 5
High efficiency wall hung condensing boilers Luna Platinum 1.12/1.18
Luna Platinum 1.24
Luna Platinum 1.32
High efficiency wall hung condensing boilers Luna Duo-tec MP 1.50
Luna Duo-tec MP 1.60
High efficiency floor standing condensing boilers Power HT 1.450
Maximum Heat Output
80째/60째 C
32 12/16,9
24
Luna Platinum HT
33,8
45
kW
Luna Duo-tec MP
Maximum Heat Output
34,9
48,6
Luna Platinum HT
Luna Duo-tec MP
36,6
48,7
Luna Duo-tec MP
Power HT
50째/30째 C kW
13,1/18,4
26,1
55
59,4
A wide range of high efficiency solutions
6
High efficiency condensing systems
Luna Luna Luna Duo-tec MP Duo-tec MP Duo-tec MP 1.110 1.90 1.70
Power HT 1.650
Power HT 1.850
Power HT 1.1000
Power HT 1.1150
Power HT 1.1200
Power HT 1.1500
Power HT 1.230
Power HT 1.280
Power HT 1.320
112
120
150
210,1
254,5
294
162
229,8
278,1
321,3
102 65
85
Luna Duo-tec MP
100 Power HT
70,2
91,8
110,2
Luna Duo-tec Luna Duo-tec Luna Duo-tec MP MP MP
70,3
91,6
107,8
Power HT
Power HT
Power HT
121,1 129,7
Baxi high efficiency condensing systems are available in a wide range of outputs from 12 to 320 kW, to satisfy every installation need (wall hung and floor standing).
7
Wireless and M-BUS built-in heat boxes Without pump (mixing valve)
With pump
To manage 2 zones
Luna SAT RC - Luna SAT RC-MB Luna SAT R/1 - Luna SAT R/1-MB Luna SAT RH - Luna SAT RH-MB Luna SAT RH1 - Luna SAT RH1-MB Luna SAT RHG1 - Luna SAT RHG1-MB
Luna SAT RP/1 - Luna SAT RP/1-MB Luna SAT RPH - Luna SAT RPH-MB Luna SAT RPB - Luna RPB-MB Luna SAT RPE - Luna SAT RPE-MB Luna SAT RPEH - Luna SAT RPEH-MB
Luna SAT R2Z Luna SAT R2Z-MB
Luna SAT RS - Luna SAT RS-MB Luna SAT RST-MB
Luna SAT RSP - Luna SAT RA Luna SAT RSP-MB Luna SAT R60 WH-MB (for wall hung installation with integrated cylinder)
Luna SAT RS2Z - Luna SAT RA2Z
Heating only
Combi
Heating and cooling
Luna SAT R2H - Luna SAT R2H-MB
- Luna Sat R/1, RH, RPB, RPE, RPEH, RH1 and RHG1 and RHG1 are available also with built-in flow-meters (M-BUS models as well) - RH1 and RH1-MB models are available also with pressure reducer on the flow-meters.
8
High efficiency condensing systems
High efficiency condensing systems Thermal systems for cascade installations Wall hung boilers - Luna Platinum - Luna Duo-tec MP - Luna HT (range available only for installation in GMC) - Cabinets with condensing high efficiency boilers (GMC)
10 11 12 13
Floor standing boilers - Power HT (outputs from 45 to 150 kW) - Power HT (outputs from 230 to 320 kW)
15 16
Wireless and M-BUS built-in heat boxes - Luna Sat-Heating only models - Luna Sat-Heating and DHW production models
17 18
9
Technical pages 20-28 33-39
40
41-42
Luna Platinum 12-32 kW • Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Integrated control of a solar system* • Complete soundproofing of the generator • Circulating pump with full modulation • Frontal access for advanced diagnostics
Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhaced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Multi-speeds low energy pump of the heating circuit with builtin air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar
Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Cascade system installation option Room sensor, central heating and sanitary timers included in the control panel
Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital central heating pressure gauge *in case of contemporary control of a solar system and a zone by the wallmounted control panel, it is necessary to install a programmable clip in/external module THINK.
10
Product code
1.12
1.18
1.24
1.32
7102665
7108435
7106583
7108436
Maximum heating heat input
kW
12,4
17,4
24,7
33
Maximum heating heat output 80/60°C
kW
12
16,9
24
32 34,9
Maximum heating heat output 50/30°C
kW
13,1
18,4
26,1
Minimum heating heat output 80/60°C
kW
2
2,4
2,4
3,2
Minimum heating heat output 50/30°C
kW
2,2
2,7
2,7
3,5
´´´´
´´´´
´´´´
´´´´
Average efficiency (DIN 4702-T8)
%
109,8
109,8
109,8
109,8
Nominal efficiency 80/60°C
%
97,8
97,7
97,6
97,6
Nominal efficiency 50/30°C
%
105,8
105,8
105,7
105,7
Efficiency 30%
%
107,8
107,7
107,6
107,6
5
5
5
5
-5
-5
-5
-5
Energetic efficiency (92/42/CEE)
NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge
°C l/bar
8/0,8
8/0,8
8/0,8
10/0,8
Heating temperature range.
°C
25/80
25/80
25/80
25/80
Maximum pressure heating circuit
bar
3
3
3
3
m
10
10
10
10
Coaxial flue system Ø 60/100 max length
m
80
80
80
80
Maximum flue mass flow rate
Dual flue system Ø 80 max length
kg/s
0,006
0,008
0,012
0,016
Minimum flue mass flow rate
kg/s
0,001
0,001
0,001
0,002
Maximum flue temperature
°C
75
75
80
80
Dimensions (h x w x d)
mm
Net weight
kg
34,5
34,5
760 x 450 x 345
Gas type Power consumption Grade of protection
34,5
37,5
Natural Gas W
108
122
120
130
IPX5D
IPX5D
IPX5D
IPX5D
High efficiency condensing systems Technical pages 21-30 33-39 39-40 41-43
Luna Duo-tec MP 50-110 kW • Stainless steel AISI 316L single chamber (50 – 60 – 70 kW) and double chamber (90 – 110 kW) exchanger: high output in compact size, reliability and long life. • High modulation ratio (1÷9): better efficiency thanks to reduced switch-on/switch-off of the boiler • Digital control panel with push buttons and wide LCD display (numbers and symbols) • Compact size and minimal weight • Complete range of accessories for single and cascade installations
Outputs from 50 to 110 kW Hydraulic system Modulating pump included in the boiler System to prevent pump sticking operating every 24 hours Flow and return NTC sensors Water tray for condensate drain from supply air duct
Thermoregulation system Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (high and low temperatures) installation option Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the control panel
Product code
1.50
1.60
1.70
1.90
1.110
7104050
7104051
7104052
7104651
7104652
Maximum heating heat input
kW
46,3
56,6
66,9
87,4
104,9
Maximum heating heat output 80/60°C
kW
45
55
65
85
102
Maximum heating heat output 50/30°C
kW
48,6
59,4
70,2
91,8
110,2
Minimum heat output 80/60°C
kW
5
6,1
7,2
9,4
11,4
Minimum heat output 50/30°C
kW
5,4
6,6
7,8
10,2
12,3
Energetic efficiency 92/42/CEE
Average efficiency (DIN 4702-T8)
%
109,8
109,8
109,8
109,8
109,8
Nominal efficiency 80/60°C
%
97,2
97,2
97,2
97,2
97,2
Nominal efficiency 50/30°C
%
105
105
105
105
105
Efficiency at 30%
%
107,8
107,4
107,1
107,5
107,4
5
5
5
5
5
NOx class (EN 483) Minimum working temperature
°C
-5
-5
-5
-5
-5
Water content
lt
4
5
6
9
10
Heating system max pressure
bar
4
4
4
4
4
Safety valve intervention pressure
bar
4
4
4
4
4
Regulation of water temperature in heating circuit
°C
25/80
25/80
25/80
25/80
25/80
Control system Full electronic anti-frost device Electronic thermometer Central heating pressure gauge Flow over-temperature thermostat
Coaxial flue system max length
m
10 (Ø 80/125)
10 (ø 80/125)
10 (ø 80/125)
10 (ø 110/160)
10 (ø 110/160)
Dual flue system max length
m
60 (ø 80)
60 (ø 80)
60 (ø 80)
27 (ø 110)
27 (ø 110)
Maximum flue mass flow rate
kg/s
0,021
0,026
0,031
0,04
0,047
Minimum flue mass flow rate
kg/s
0,002
0,003
0,004
0,005
0,005
Maximum flue temperature
°C
80
80
74
70
70
Dimensions (h x w x d)
mm
766x450x377
766x450x377
766x450x505
952x600x584
952x600x584
Net weight
kg
40
40
50
83
93
Nat. gas/LPG
Gas type Power consumption Grade of protection
W
190
210
210
275
320
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
11
Luna HT 45-100 kW • Stainless steel double chamber exchanger: high output in compact size, reliability and long life • Digital control panel “advanced CPS system” with push buttons and wide LCD display with text and symbols • Minimal weight and size • Complete range of accessories for the climatic control • Range available only for installation in GMC
Outputs from 45 to 100 kW Hydraulic system Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue exchanger System to prevent pump sticking operating every 24 hours
Thermoregulation system Remote controller and climatic regulator (supplied as optional) Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (low and high temperature) installation option Cascade system installation option NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the
1.450 Product code
1.450P*
1.550
1.650
1.850
1.1000
HSB 43545300 43545364 43555300 43565300 43508500 43510000
Maximum heating heat input
kW
46,4
46,4
56,7
67
87,2
105
Maximum heating heat output 80/60°C
kW
45
45
55
65
85
102
Maximum heating heat output 50/30°C
kW
48,7
48,7
59,5
70,3
91,6
110,3
Minimum heat output 80/60°C
kW
14,5
14,5
15,5
19,3
25,7
29
Minimum heat output 50/30°C
kW
15,8
15,8
16,8
21
27,8
31,4
Energetic efficiency 92/42/CEE
Average efficiency (DIN 4702-T8)
%
109,8
109,8
109,8
109,8
109,8
109,8
Nominal efficiency 80/60°C
%
97,3
97,3
97,4
97,4
97,5
97,4
Nominal efficiency 50/30°C
%
105,1
105,1
105,0
105,2
105,1
105,1
Efficiency at 30%
%
107,6
107,6
107,5
107,6
107,3.
107,4
5
5
5
5
5
5
NOx class (EN 483) Minimum working temperature
°C
-5
-5
-5
-5
-5
-5
Water content
lt
5,1
5,1
5,6
6,5
13,7
21
Heating system max pressure
bar
4
4
4
4
4
4
Safety valve intervention pressure
bar
3
3
3
3
3
3
Regulation of water temperature in heating circuit
°C
25/80
25/80
25/80
25/80
25/80
25/80
Control system
Coaxial flue system max length
m
10 (ø 80/125) 10 (Ø 80/125) 10 (ø 80/125)
10 (ø 80/125) 10 (ø 110/160) 10 (ø 110/160)
Central heating and indirect cylinder timer Hydraulic pressure switch to prevent boiler operating in the event of low water Full electronic anti-frost device Electronic thermometer Central heating pressure gauge
Dual flue system max length
m
60 (ø 80)
60 (ø 80)
60 (ø 80)
60 (ø 80)
Maximum flue mass flow rate
kg/s
0,022
0,022
0,027
0,032
0,041
0,050
Minimum flue mass flow rate
kg/s
0,007
0,007
0,008
0,010
0,013
0,015
Maximum flue temperature
°C
74
74
78
75
74
79
Dimensions (h x w x d)
mm
950x600x466
950x600x466
950x600x466
950x600x466
950x600x650
950x600x650
Net weight
kg
64
64
68
72
94
98
control panel
Nat. gas/LPG
Gas type Power consumption Grade of protection
12
(*) Model with integrated pump
27 (ø 110) 27 (ø 110)
W
75
75
80
125
150
200
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
High efficiency condensing systems Technical pages
22
Cabinets with condensing high efficiency boilers (GMC) • Minimum overall dimensions and maximum compactness • Easy installation in heating systems renovation • High flexibility: possibility to connect up to 3 cabinets with flow and return hydraulic connections on the left or on the right side • Easy installation and quick connection • Easy handling with a mechanical power-lift option • Suitable for outdoor installation • Hydraulic accessories for cascade installation
CABINET made of:
N° of installed Boilers
LUNA HT possible configuration
1.450 1.550 1.650
Hydraulic system Hydraulic connections between boilers and copper collectors Integration of the hydraulic safety accessories Expansion vessels included Flow/return right or left side
2
or
doors* 1.850 1.1000
3
1.450 1.550 1.650
or
doors* 1.850 1.1000
Tot. installed kW
45 55 65 85 90 100 110 120 130 170 185 200
90 100 110 120 130 135 145 155 165 170 175 185 195 200 255 270 285 300
* to install the hydraulic compensator and the system accessories sheltered from the bad weather it is possible to order an additional cabinet
13
Integrated and compact system by Baxi for centralized, commercial installations and buildings Baxi has developed cabinets where Luna HT boilers can be installed to have high performance (efficiency up to 109,8%) and low pollutant emissions. The range of Baxi cabinets allows solutions up to 3 doors, from 45 kW (1 cabinet with 2 doors 1x45 kW) to 600 kW ( 2 cabinets with 3 doors 3x100 kW). They are ideal for centralized, commercial applications and buildings. It is possible to integrate them with the Baxi wide range of heat-boxes, LUNA SAT.
Dual flue terminal
Hydraulic separator (not included). It is made of: - frame - pipes - separator
Condensing trap
Return manifold
Eletric box (not included)
Holes for handling Flow manifold
14
Cabinet
Manifold (flow/return/gas)
High efficiency condensing systems
Power HT 45-150 kW
Technical pages 23-31 35-39
40
41-43
• Stainless steel double chamber exchanger: high output in compact size, reliability and long life • Digital control panel “advanced CPS system” with push buttons and wide LCD display with text and symbols • Complete range of temperature regulation accessories • Minimal weight and size • Complete range of accessories for single and cascade installations
Outputs from 45 to 150 kW
Hydraulic system Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue exchanger System to prevent pump sticking operating every 24 hours
Thermoregulation system Remote controller and climatic regulator (supplied as optional) Built-in weather compensation function (outdoor sensor supplied as optional) Mixed zones systems (low and high temperature) installation option Cascade system installation option NTC sensor for DHW cylinder control option
Control system Central heating and indirect cylinder timer Hydraulic pressure switch to prevent boiler operating in event of low water Full electronic anti-frost device Electronic thermometer Central heating pressure gauge
1.450 Product code
WHS
1.650
1.850
1.1000
1.1150
1.1200
1.1500
43104560 43106560 43108560 43110060 43111260 43112060 43115060
Maximum heating heat input
kW
46,4
67
87,2
102,7
115
123,2
154
Maximum heating heat output 80/60°C
kW
45
65
85
100
112
120
150
Maximum heating heat output 50/30°C
kW
48,7
70,3
91,6
107,8
121,1
129,7
162
Minimum heat output 80/60°C
kW
11,8
13,4
32,2
35,8
39
39
40,4
Minimum heat output 50/30°C
kW
12,8
14,5
34,9
38,8
42,1
42,1
43,7
Energetic efficiency 92/42/CEE
Average efficiency (DIN 4702-T8)
%
109,8
109,8
109,8
109,8
109,8
109,8
109,8
Nominal efficiency 80/60°C
%
97,3
97,3
97,5
97,4
97,4
97,4
97,4
Nominal efficiency 50/30°C
%
105,2
105,3
105,1
105
105,3
105,3
105,2
Efficiency at 30%
%
107,6
107,6
107,3
107,4
107,5
107,5
107,2
5
5
5
5
5
5
5 -5
NOx class (EN 483) Minimum working temperature
°C
-5
-5
-5
-5
-5
-5
Safety valve intervention pressure
bar
3
3
3
3
3
3
3
Heating system max pressure
bar
4
4
4
4
4
4
4
Regulation of water temperature in heating circuit
°C
25/80
25/80
25/80
25/80
25/80
25/80
25/80
Primary circuit water flow (∆T=20°C)
l/h
1.935
2.795
3.700
4.300
4.800
5.200
6.500
l
5,1
6,5
13,7
21
23,3
23,3
25,3
ø mm
80
80
100
100
100
100
100
Water content Flue tube
m
30
20
20
20
20
20
20
Maximum flue mass flow rate
Flue ducts max length
kg/s
0,022
0,031
0,041
0,049
0,054
0,059
0,073
Minimum flue mass flow rate
kg/s
0,006
0,007
0,016
0,018
0,019
0,019
0,02
Maximum flue temperature
°C
72
73
78
80
72
77
75
Dimensions (h x w x d)
mm
850x450x621
850x450x693
850x450x801
850x450x871
850x450x1024
850x450x1024
850x450x1132
kg
60
68
75
83
95
95
103
128
135
235
Net weight Gas type Power consumption
Nat. gas/LPG W
90
110
100
160
15
Technical pages 25-31 37-38
43
Power HT 230-320 kW • Aluminium-Silicon exchanger with glass wool insulation: high efficiency and reliability • High modulation ratio (1÷6) • Digital control panel with knob, buttons and wide backlighted LCD display with text and symbols • Easy to transport and to install • Quiet operation
Outputs from 230 to 320 kW
Hydraulic system Hydraulic connections on the rear side Sticking pump check system Flow and return NTC sensors Premixed low-emissions burner
Thermoregulation system Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (high and low temperatures) installation option Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the control panel
Control system Full electronic anti-frost device Electronic thermometer Flow over-temperature thermostat
Power HT 1.230
Power HT 1.280
Power HT 1.320
Product code
LSX
411230600 .
411280600 .
411320600 .
Nominal heat output
kW
215,0
260,0
300,0
Maximum heating heat output 80/60°C
kW
210,1
254,5
294,0
Maximum heating heat output 50/30°C
kW
229,8
278,1
321,3
Minimum heat output 80/60°C
kW
33,5
40,2
45,9
Minimum heat output 50/30°C
kW
37,4
44,9
51,4
´´´´
´´´´
´´´´
Average efficiency (DIN 4702-T8)
%
109,6
109,7
109,7
Nominal efficiency 80/60°C
%
97,9
98,0
98,0
Nominal efficiency 50/30°C
%
106,9
107,0
107,1
Efficiency at 30%
%
105,4
105,6
105,7
5
5
5
Energetic efficiency 92/42/CEE
NOx Class (EN 483) Minimum working temperature
°C
-5
-5
-5
Heating system max pressure
bar
6
6
6
Water content
lt
38
45
53
Flue ducts max length
m
60 (Ø200)
60 (Ø200)
60 (Ø200)
Maximum flue mass flow rate
kg/s
0,097
0,118
0,136
Minimum flue mass flow rate
kg/s
0,016
0,019
0,021
Maximum flue temperature
°C
61
60
60
Dimensions (h x w x d)*
mm
1458x692x1231
1458x692x1324
1458x692x1417
Net weight
kg
285
314
344
Gas type Power consumption (*) Flue ducts and hydraulic pipes included
16
Natural Gas / LPG W
330
350
410
High efficiency condensing systems Info Tech pages 44-45
Luna Sat-Heating only models
RC: KSV 71413111 RC-MB: KSV 71413121
R/1: KSV 71411151 R/1-MB: KSV 71411541
RP/1: KSV 71411161 RP/1-MB: KSV 71411551
R2Z: KSV 71410101 R2Z-MB: KSV 71411901
RH: KSV 71411321 RH-MB: KSV 71411591
RPH: KSV 71411331 RPH-MB: KSV 71411601
RPB: KSV 71411171 RPB-MB: KSV 71411581
RPE: KSV 71411911 RPE-MB: KSV 71411921
RH1: KSV 71411811 RH1-MB: KSV 71411851
RPEH: KSV 71412451 RPEH-MB: KSV 71412461
RHG1: KSV 71412361 R2H: KSV 71412041 RHG1-MB: KSV 71412371 R2H-MB: KSV 71412051
RC
R/1
RP/1
R2Z
RH
RPH
RPB
RPE
RPEH
RH1
RHG1
R2H**
Models with pump
-
-
•
•
-
•
•
•
•
-
-
-
Models with 2nd zone
-
-
-
•
-
-
-
-
-
-
-
-
-
-
-
25/80
-
-
-
25/80
-
-
-
-
Heating temperature regulation with high climatic curve
°C
Heating circuit maximum pressure
bar
4
4
4
4
4
4
4
4
4
4
4
4
I
0,5
1,5
2
3,5
1,5
2
2
2
2
1,5
2
1,5
Power supply voltage
V
230
230
230
230
230
230
230
230
230
230
230
230
Power supply frequency
Hz
50
50
50
50
50
50
50
50
50
50
50
50
Power consumption
W
15
15
110
210
15
110
110
110
110
15
15
15
Width of the case
mm
450
600
600
800
650
600*
600
600
600
400*
500
800
Height of the case
mm
450
650
650
750
650
716*
650
650
850
600*
850
750
Depth of the case
mm
110
150
150
150
150
150*
150
150
150
200*
150
150
Net weight
Kg
3,2
11
13
22
11
13
12
13,50
14
9
13
9
Maximum temperature of the warm fluid (inlet)
°C
90
90
90
90
90
90
90
90
90
90
90
90
Feed flow (inlet)
l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
700÷ 1000 l/h
Flow-losses
kPa
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
Water contents
(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps (**) For heating and cooling
17
Info Tech pages 44-45
Luna Sat-Heating and DHW production models
RS: KSV 71410081 RS-MB: KSV 71411561
RSP: KSV 71410091 RSP-MB: KSV 71411571
RS2Z: KSV 71410111
RA2Z: KSV 71410781
RA: KSV 71410771
R60WH-MB KSV 71413071
RST-MB: KSV 71413971
RS
RSP
RS2Z
RA
R60WH
RA2Z
RST
DHW production
•
•
•
•
•
•
•
Models with pump
-
•
•
•
•
•
-
Models with 2nd zone
-
-
•
-
-
•
-
Heating temperature regulation with high climatic curve
°C
25/80
25/80
25/80
25/80
25/80
25/80
25/80
DHW regulation
°C
30/60
30/60
30/60
30/65
30/65
30/65
30/60
DHW production with ∆T=35°C and inlet water temperature 75°C
l/m
14,3
14,3
14,3
14,3
14,3
14,3
14,3
Heating circuit maximum pressure
bar
4
4
4
4
4
4
4
DHW circuit maximum pressure
bar
8
8
8
8
8
8
8
DHW circuit minimum pressure
0,2
bar
0,2
0,2
0,2
0,2
0,2
0,2
Water contents
l
2
2,5
4
2
5
4
2
Power supply voltage
V
230
230
230
230
230
230
230
Power supply frequency
Hz
50
50
50
50
50
50
50
Power consumption
W
15
110
210
150
110
210
15
Width of the case
mm
600
600
800
600
910
800
600
Height of the case
mm
650
650
750
650
450
750
600
Depth of the case
mm
150
150
150
150
473
150
150
Net weight
Kg
16
18
28
16
38
25
16
Maximum temperature of the warm fluid (inlet)
°C
90
90
90
90
90
90
90
Feed flow (inlet)
l/h
1000÷ 1500
1000÷ 1500
1000÷ 1500
1000÷ 1500
1000÷ 1500
1000÷ 1500
1000÷ 1500
Flow-losses
kPa
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
20Kpa at 700 l/h
18
High efficiency condensing systems
Technical Section
Technical drawings Graphs Flue systems
20
Flue pipes accessories
32
Hydraulic accessories
39
Thermoregulation accessories
41
Other accessories
44
Products technical data
46
19
High efficiency condensing system Luna Platinum 1.12-1.18-1.24-1.32 140,5
131min.
177
M.B.
760
450
S.C. M.R. M.B. GAS E.S. R.R.
Condensing trap that can be installed on a Ø 21 pipe Heating system flow G 3/4” Storage tank flow G 3/4” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”
6 5,5 5 4,5 4 3,5 3 2,5 2 1,5 1
FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE
FLOW RATE/HEAD CURVE
Flues temperature %
HEAD
345
MAX MIN
200
400
800
600
1000
1200
Efficiency of the boiler %
30% load
108 107 106 105 104 103 102 101 100 99 98 97
30% load
40
45
40
45
50
Return temperature of the system °C
100% load
35
35
1400
EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE
20
100% load
30 0
FLOW RATE (l/h)
30
75 70 65 60 55 50 45 40 35 30
50
Return temperature of the system °C
55
60
55
60
Technical drawings - graphs - flue systems
High efficiency condensing system Luna Duo-tec MP
Luna Duo-tec MP 1.90-1.110
1.50-1.60-1.60 450 225
(A)
140
223 952
229
763
225
600 354,5
584 245,5
112
(A) 377 mm Mod. 1.50-1.60 505 mm Mod. 1.70 Coaxial flue system ø 80/125 Dual flue system ø 80 GAS M.R.
S.C
GAS
M.R.
R.R.
R.R. S.C.
Coaxial flue system Dual flue system
Entrata Gas inlet G ¾” Heating system flow (G1”) with cylinder connection option Heating system return (G1”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe
ø 110/160 ø 110 GAS M.R.
S.C
GAS
M.R.
R.R.
Gas inlet G 1” Heating system flow (G1-G1/2”) with cylinder connection option Heating system return (G1-1/2”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe
R.R.
S.C.
FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.70
FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.90
HEAD (mH2O)
HEAD (mH2O)
HEAD (mH2O)
FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.50 - 1.60
FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.110
EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE
108 107 106 105 104 103 102 101 100 99 98 97
30% load 100% load
30
FLOW RATE (l/h)
FLOW RATE (l/h)
35
40
45
50
FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE
Flues temperature %
Efficiency of the boiler %
FLOW RATE (l/h)
HEAD (mH2O)
FLOW RATE (l/h)
55
Return temperature of the system °C
60
75 70 65 60 55 50 45 40 35 30
100% load
30% load
30
35
40
45
50
55
60
Return temperature of the system °C
21
High efficiency condensing system GMC
2 door cabinet dimensions (mm) Modules
W
H
D
2 doors
1600
1900
800
3 door cabinet dimensions (mm) Modules
W
H
D
3 doors
2400
1900
800
1900
190
Ă˜149
228
290
194
124
417
2400
309
Luna HT Residential 45-55-65 kW 800
800
277,5
22
160 800
331
Luna HT Residential 85-100 kW 355
454,5 182,5
445
77
800
800
345,5
Technical drawings - graphs - flue systems
High efficiency condensing system Power HT 45-150 kW Placement RVA
Power HT
FLOW RATE/HEAD CURVE
Depth (A) mm
HEAD (mH2O)
Power HT To allow an easy access for the boiler maintenance, the minimum recommended distance must be observed
FLOW RATE (l/h)
45 cm
45 cm/ 2 cm
EXCHANGER PRESSURE LOSS (mH2O)
EXCHANGER PRESSURE LOSS
45 cm/ 2 cm
FLOW RATE (l/h) EXCHANGER PRESSURE LOSS EXCHANGER PRESSURE LOSS (mH2O)
EXCHANGER PRESSURE LOSS (mH2O)
EXCHANGER PRESSURE LOSS
FLOW RATE (l/h)
FLOW RATE (l/h)
23
High efficiency condensing system
186,5
936,5
136,5
800
Power HT 45-150 kW
20 * 450
450
20* 450
436,5
(*) - The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used. Flow/return manifolds squared 100x100 with flanges DN80 PN6 24
Technical drawings - graphs - flue systems
High efficiency condensing system Power HT 230-320 kW
Flow
Flange
Return Flange
Power HT
1.230
1.280 1.320
Depth (A) mm
1.269
1.362 1.452
HEAT PRODUCTION ACCORDING TO THE OUTDOOR TEMPERATURE T
H 80 R 0 23 .2 E 1. T 1 OW T H RH P ER E W OW PO P
Characteristic curve
Hea
ting
flow
Heati
Dew point = 54째C
ng re
turn
100
Outdoor temperature 째C 10
EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT
1 1
0
1
FLOW RATE [m3/h]
100
Efficiency%
WATER SIDE RESISTANCE (mbar)
1000
0
32
1.
Heating water temperature
EXCHANGER PERSSURE LOSSES
Output %
25
High efficiency condensing system Power HT 230-320 kW
@
A
1 Remove lower rear wall (2) of the Power HT
Side supply air connection (A)
Rear supply air connection (B)
2 Remove the gas connection leading upward
1 Remove lower rear wall (3)
1 Remove lower rear wall (2)
2 Remove the covering panel (2)
2 Take out cover plate (3)
3 Mount the bend of the intake pipe (1)
3 Mount straight intake pipe
4 Turn intake pipe elbow into the side position (1)
4 Mount lower rear wall (2)
and insert a 87°bend (1) 3 Turn 87°bend (1) in the desired position (side or towards the rear) 4 Remove either the rear cover plate (3) or the
5 Mount lower rear wall (3)
side cover plate (4) 5 Mount lower rear wall (2)
Max lengths for the flue pipes with room air dependent working (type B installation)
Model
Power HT 1.230
Power HT 1.280
Power HT 1.320
Flue pipe - ø
mm
200
200
200
Max L. pipe inc. 87° bend
mm
60
60
60
These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m 1 piece 45° bend: 2 m 1 piece 15° bend: 1 m
26
Technical drawings - graphs - flue systems
Coaxial flue system Luna Platinum
GSPOUBM WJFX
TJEF WJFX
Example of installation with horizontal flue system Ă˜ 60/100 and Ă˜ 80/125
Tubes maximum length (m)
Installation examples with LAS chimney Ă˜ 60/100 and Ă˜ 80/125
Ă˜ 60/100
Ă˜ 80/125
10
25
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
1
0,5
Installation example with vertical coaxial flue ducts Ă˜ 60/100 and Ă˜ 80/125
Vertical chimney terminal for coaxial flue system
ø
ø
ø ø
,)( 7FSUJDBM DIJNOFZ UFSNJOBM GPS DPBYJBM ðVF TZTUFN ø
,)( 3FEVDUJPO GSPN ø UP ø
27
Dual flue system Luna Platinum
GSPOUBM WJFX
TJEF WJFX
Example of installation with vertical dual flue system
GSPOUBM WJFX
TJEF WJFX
Installation example with horizontal dual flue ducts
Intake pipe maximum length: 15 m.
Vertical chimney terminal for dual flue system
ø
ø
,)( 7FSUJDBM DIJNOFZ UFSNJOBM ø
28
,)( %VBM ðVF QJQFT BEBQUFS GPS DPBYJBM DIJNOFZ ø UP ø
Technical drawings - graphs - flue systems
Flue system – Coaxial flue system Luna Duo-tec MP Type of duct
Tubes maximum length (m)
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
Ø chimney terminal (mm)
Ø external duct
Coaxial Ø 110/160 mm
10 m
1m
0,5 m
163 mm
160 mm
Vertical dual flue system
15 m
0,5 m
0,25 m
163 mm
110 mm
Coaxial Ø 85/125 mm
10 m
1m
0,5 m
133 mm
125 mm
Vertical dual flue system
15 m
0,5 m
0,25 m
133 mm
80 mm
Horizontal dual flue system*
60 m
0,5 m
0,25 m
-
80 mm
* intake pipe maximum length: 15 m.
COAXIAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80/125 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110/160 mm
DUAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80+80 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110+110 mm
Luna Duo-tec MP – Coaxial flue system Installation example with coaxial flue ducts Ø 80/125 (mod. 1.50 - 1.60 - 1.70) and Ø 110/160 (mod. 1.90 - 1.110)
29
Dual flue system Luna Duo-tec MP 1.50 - 1.70
Luna Duo-tec MP 1.90 - 1.110
Installation example with horizontal dual flue ducts
Intake pipe maximum length: 15 m
Example of installation with vertical dual flue system
30
Technical drawings - graphs - flue systems
Flue system Power HT (45-150 kW) – Flue pipe
Model
Tubes maximum length (m)
Length reduction for a 90° bend insertion (m)
Length reduction for a 45° bend insertion (m)
30 20 20 20 20 20 20
1 1 1 1 1 1 1
0,5 0,5 0,5 0,5 0,5 0,5 0,5
HT 1.450 HT 1.650 HT 1.850 HT 1.1000 HT 1.1150 HT 1.1200 HT 1.1500
Power HT (230-320 kW) – Flue/Intake pipes
flow flange DN 65
return flange DN 65
Ø flue pipe Tube maximum length including 1 87° bend (m)
Power HT 1.230
Power HT 1.280
Power HT 1.320
mm
200
200
200
mm
60
60
60
These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m
31
Accessories for high efficiency condensing systems Flue Systems - Coaxial flue - Dual flue - Flue accessories for cascade installation - Flexible ducting system
32
33 34 38 39
Hydraulic accessories
39
Thermoregulation accessories
41
Accessories available as option for Luna SAT
44
Flue pipe accessories Coaxial flue system: Luna Platinum - Luna Duo-Tec MP 50-70 kW Description
Code
PP coaxial flue pipe with terminal Ø 80/125 L=1000 mm supplied with wind proof terminal and sealing collar
KHG 714088910 •
PP coaxial flue pipe extension Ø 80/125 L=1000 mm
KHG 714088511 •
PP coaxial flue pipe extension Ø 80/125 L=500 mm
KHG 714088610 •
PP coaxial 90° bend - Ø 80/125
KHG 714088711 •
PP coaxial 45° bend - Ø 80/125
KHG 714088811 •
Coaxial flue system: Luna Platinum Description
Code
PP coaxial flue pipes with terminal Ø 60/100 L=750 mm supplied with windproof terminal and sealing collar
KHG 714059613
•
PP coaxial flue pipe extension Ø 60/100 L=1000 mm
KHG 714059516
•
PP coaxial flue pipe extension Ø 60/100 L=500 mm
KHG 714119810
•
PP coaxial 90° bend - Ø 60/100
KHG 714059717 •
PP coaxial 45° bend - Ø 60/100
KHG 714059817 •
Internal sealing collar Ø 100
KHG 714017710 •
PP vertical chimney terminal Ø 80/125(1)
KHG 714093510 •
PP reduction from Ø 80/125 to 60/100
KHG 714093910 •
Flat roof tile to be used with a vertical chimney terminal Ø 80/125
KHG 714093610 •
Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°
KHG 714093710 •
(1)
+KHG 714093910 •
Coaxial flue system: Luna Duo-Tec MP 50-70 kW Description
Code
PP vertical chimney terminal Ø 80/125
KHG 714093510 •
Flat roof tile to be used with a vertical chimney terminal Ø 80/125
KHG 714093610 •
Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°
KHG 714093710 •
33
Flue pipe accessories Coaxial flue system: Luna Duo-Tec MP 90-110 kW Description
Code
PP coaxial flue pipe extension Ø 110/160 L=1000 mm
KUG 714133810 •
PP coaxial flue pipe extension Ø 110/160 L=500 mm
KUG 714133710 •
PP coaxial 90° bend - Ø 110/160
KUG 714133610 •
PP coaxial 45° bend - Ø 110/160
KUG 714133510 •
PP vertical chimney terminal Ø 110/160
KUG 714133410 •
PP horizontal coaxial chimney Ø 110/160
KUG 714133310 •
Flat roof tile to be used with a vertical chimney terminal Ø 110/160
KHG 714104810 •
Pitched roof tile to be used with a vertical chimney terminal Ø 110/160; it is adjustable from 15° to 45°
KHG 714104910 •
Dual flue system: Luna Platinum
34
Description
Code
Orientable dual flue system
710268902 •
PP dual flue system Ø 80 it includes: flue reduction, intake connection
KHG 714059113 •
PP vertical flue system B23 type installation
KHG 714111011 •
PP pipe extension Ø 80 L=1000 mm
KHG 714059411 •
PP pipe extension Ø 80 L=500 mm
KHG 714059910 •
PP pipe extension Ø 80 L=250 mm
710718301 •
PP 90° bend Ø 80
KHG 714059211 •
PP 45° bend Ø 80
KHG 714059311 •
Dual flue terminal Ø 80
KHG 714010410 •
PP reduction from Ø 80 to Ø 60
KHG 714075610 •
PP pipe extension Ø 60 L=1000 mm
KHG 714075310 •
PP pipe extension Ø 60 L=500 mm
KHG 714075210 •
PP 90° bend Ø 60
KHG 714075410 •
PP 45° bend Ø 60
KHG 714075510 •
Flue pipe accessories Dual flue system: Luna Platinum Description
Code
Dual flue terminal Ø 60
KHG 714037210 •
Pipe Ø 80 centring kit (pack of 5)
KHG 714037411 •
Clamp centring kit Ø 80
KHG 714106110 •
Pipe Ø 60 centring kit (pack of 5)
KHG 714051510 •
Pipe Ø 80 supporting bracket (pack of 5)
KHG 714037310 •
Internal sealing collar Ø 80
KHG 714018510 •
External sealing collar Ø 80
KHG 714018411 •
Coaxial vertical chimney terminal Ø 80/125(1)
KHG 714093510 •
Dual flue pipes adapter for coaxial chimney Ø 80/125
KHG 714093810 •
Flat roof tile Ø 125 to be used with a vertical chimney terminal
KHG 714093610 •
Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°
KHG 714093710 •
(1)
+KHG 714093810 •
Dual flue system: Luna Duo-Tec MP 50-70 kW - floor standing boilers 45-65 kW Description
Code
PP pipe extension Ø 80 L=1000 mm
KHG 714059411 •
PP pipe extension Ø 80 L=500 mm
KHG 714059910 •
PP pipe extension Ø 80 L=250 mm
710718301 •
PP 90° bend Ø 80
KHG 714059211 •
PP 45° bend Ø 80
KHG 714059311 •
Pipe Ø 80 centring kit (pack of 5)
KHG 714037411 •
Clamp centring kit Ø 80
KHG 714106110 •
Pipe Ø 80 supporting bracket (pack of 5)
KHG 714037310 •
Internal sealing collar Ø 80
KHG 714018510 •
External sealing collar Ø 80
KHG 714018411 •
Flue terminal Ø 80
LSD 790000150 •
Dual flue terminal Ø 80
KHG 714010410 •
35
Flue pipe accessories Dual flue system: Luna Duo-Tec MP 50-70 kW Description
Code
PP dual flue system Ø 80 it includes: flue reduction, intake connection
KHG 714089010 •
Coaxial vertical chimney terminal 80/125
KHG 714093510 •
Dual flue pipes adapter for coaxial chimney Ø 80/125
KHG 714093810 •
Flat roof tile Ø 125 to be used with a vertical chimney terminal
KHG 714093610 •
Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°
KHG 714093710 •
Dual flue system: Luna Duo-Tec MP 90-110 kW Description
Code
PP dual flue kit Ø 110/110
710631401 •
Dual flue system: Luna Duo-Tec MP 90-110 kW - floor standing boilers 85-150 kW Description
Code
PP pipe extension Ø 110 L=1000 mm
KUG 714133210 •
PP pipe extension Ø 110 L=500 mm
KUG 714133110 •
PP pipe extension Ø 110 L=250mm
710718501 •
PP 90° bend Ø 110
KUG 714133010 •
PP 45° bend Ø 110
KUG 714132910 •
PP reduction kit from Ø 110 to Ø 100(1)
KHW 714096910 •
PP vertical chimney terminal Ø 110
KUG 714132810 •
PP horizontal chimney terminal Ø 110
KUG 714132710 •
Flat roof tile to be used with a vertical chimney terminal Ø 110/160
KHG 714104810 •
Pitched roof tile to be used with a vertical chimney terminal 110/160; it is adjustable from 15° to 45°
KHG 714104910 •
(1)
36
only for floor standing boilers 85-150 kW
Flue pipe accessories Dual flue system: floor standing boilers 230-320 kW Descrizione
Codice
Extension pipe Ø 200 L=500 mm
LXO 000971911 •
Extension pipe Ø 200 L=1000 mm
LXO 000971928 •
Extension pipe Ø 200 L=2000 mm
LXO 000971935 •
87° bend Ø 200
LXO 000971942 •
45° bend Ø 200
LXO 000971959 •
Spacer Ø 200
LXO 000971973 •
Pitched roof tile Ø 200
LXO 000971997 •
SAS flue discharge 200-1B
LXO 000688673 •
SAS flue discharge 200-2B
LXO 000688680 •
Air grid Ø 200
LXO 000971980 •
87° bend Ø 200 with inspection
LXO 000971904 •
Up right duct with inspection hole
LXO 000971898 •
SAS vertical chimney terminal Ø 200
LXO 000989527 •
Passing roof Ø 200
LXO 000989497 •
Comburent air filter
LXO 000692656 •
Room air indipendent working (WAS 200)
LXO 000971881 •
37
Flue pipe accessories Flue accessories for cascade installation (for all boilers model, except for floor standing boilers 230-320 kW) Description
Code
PP flue pipe kit Ø 160 for two boilers
710715201 •
PP flue pipe kit Ø 200 for two boilers
710715601 •
PP flue pipe kit Ø160 for the third boiler
710716301 •
PP flue pipe kit Ø200 for the third boiler
710716401 •
PP 87° bend Ø160
KHW 714097810 •
PP 87° bend Ø200
KHW 714098210 •
PP pipe extension Ø160 L=1000 mm
KHW 714097710 •
PP pipe extension Ø200 L=1000 mm
KHW 714098110 •
Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 50-70 kW - floor standing boilers 45-65 kW Description
Code
PP flue pipe kit for two boilers Ø 125
710716801 •
PP flue pipe kit Ø125 for the third boiler
710717701 •
PP shutter kit Ø 110/80 with condensing trap
710682001 •
PP 90° bend Ø 125
KHG 714094410 •
PP 45° bend Ø 125 (pack of 2)
KHG 714094510 •
PP pipe extension Ø 125 L=1000
KHG 714094610 •
Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 90-110 kW - floor standing boilers 85-150 kW Description
Code
PP shutter kit Ø 110/110 with condensing trap
710682101 •
Flue accessories for cascade installation: floor standing boilers 85-150 kW Description
Code
PP reduction kit from Ø 110 to Ø 100
KHW 714096910 •
Flue accessories for cascade installation: floor standing boilers 230-320 kW
38
Description
Code
Manifold for 2 boilers in cascade 250 mm
LXO 000691444 •
Flue pipe accessories Flexible ducting system accessories: wall hung - floor standing boilers 45-65 kW Description
Code
PP flexible pipe Ø 80 L= 1,5 m
KHG 714105710 •
PP flexible pipe Ø 80 L= 20 m
KHG 714105810 •
PP tee joint Ø 80 with supporting bracket and condensate drainings
KHG 714105910 •
PP 90° bend Ø 80 with supporting bracket
KHG 714106010 •
Flexible centring kit Ø 80 (pack of 3)
KHG 714106210 •
Triple lips gaskets kit Ø 80 (pack of 5)
KHG 714111210 •
Hydraulic accessories: Luna Duo-tec MP 50-110 kW Description
Code
Manifold for separator 8,5 m3/h
710686501 •
Manifold ins. kit for separator 8,5 m3/h
710687901 •
Flanges and gaskets kit for separator 8,5 m3/h
LSD 790000440 •
Hydraulic separator HS 8.5 of 8,5 m³/h - 2” threaded connectors
LSD 790000310 •
Manifold for separator 18 m3/h
710687501 •
Manifold ins. kit for separator 18 m3/h
710688901 •
Flanges and gaskets kit for separator 18 m3/h
LSD 790000430 •
Hydraulic separator HS 18 of 18 m³/h - Ø 65 flanged connectors
LSD 790000320 •
Manifold for separator 28 m3/h
710687601 •
Manifold ins. kit for separator 28 m3/h
710689201 •
Flanges and gaskets kit for separator 28 m3/h
LSD 790000420 •
Hydraulic separator HS 28 of 28 m³/h - Ø 80 flanged connectors
LSD 790000330 •
Hydraulic separator HS 56 of 56 m³/h - Ø 100 flanged connectors
LSD 790000340 •
Neutralizer kit for wall hung boilers up to 350 kW
KHG 714125710 •
Recharge for neutralizer kit for wall-hung boilers up to 350 kW
KHG 714135410 •
39
Hydraulic accessories: Luna Platinum Description
Code
Manifold pipes for 2 Platinum boilers in cascade
KHG 714117111 •
Manifold pipes for the 3rd Platinum boiler in cascade
KHG 714117211 •
Neutralizer kit for wall hung boilers up to 100 kW
KHG 714125610 •
Recharge for neutralizer kit for wall-hung boilers up to 100 kW
KHG 714135310 •
Heating systems taps and connection pipes
710931401 •
Hydraulic accessories: Luna Duo-tec MP Description
Code
Safety device ISPESL (available as optional - compulsory accessory only for Italian market)
KHW 714098411 •
Neutralizer kit for wall hung boilers up to 100 kW
KHG 714125610 •
Recharge for neutralizer kit for wall-hung boilers up to 100 kW
KHG 714135310 •
Hydraulic accessories: floor standing boilers 45-150 kW
40
Description
Code
Safety device ISPESL (available as optional - compulsory accessory only for Italian market)
KHW 714098411 •
Manifold pipes single boiler/last boiler
KHW 714104210
•
Boiler-manifold pipe hydraulic connection
KHW 714104311
•
Manifold pipes boilers in cascade (45 cm between the boilers)
KHW 714099010 •
Manifold pipes boilers in cascade (2 cm between the boilers)
KHW 714103611 •
Hydraulic connection for 2nd pump
KHW 714098611 •
Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum - Luna Duo-tec MP floor standing boilers 45-150 kW Description
Code
Mixing valve motor
KHG 714078511 •
Mixing valve G1”
KHG 714078310 •
Mixing valve G1/2”
KHG 714078610 •
Mixing valve G3/4”
KHG 714078710 •
Flow/return sensor for controller for boilers in cascade and mixing system
KHG 714078810 •
Flow sensor for clip-in module
KHG 714078910 •
Hot water temperature sensor
KHG 714076810 •
Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description
Code
Outdoor sensor THINK
710487301 •
Outdoor sensor THINK (wireless)*
710302701 •
Interface kit for remote control THINK - 3 leds
710234002 •
Interface kit for remote control THINK - 5 leds wireless
710244102 •
Wireless aerial THINK
710234301 •
Room thermostat THINK
710106105 •
Room thermostat (wireless) THINK*
710304404 •
Room thermostat with timer THINK
710298005 •
Room thermostat with timer THINK – wireless*
710297904 •
* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 •) or the wireless aerial THINK (710234301 •)
41
Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description
Code
Programmable clip-in module THINK
710034502 •
Flow sensor for clip-in module THINK
KHG 714078910 •
Programmable external module THINK
710503704 •
Hot water temperature sensor
KHG 714076810 •
Interface kit for boilers in cascade THINK
710440802 •
Climate controller kit for mixing zones THINK
710519902 •
Sensor for solar controller
LNC 710000040 •
Accessories for the thermoregulation, programming, setting and digital control - Luna Duo-tec MP Description
Code
Outdoor sensor THINK
710487301 •
Outdoor sensor THINK (wireless)*
710302701 •
Wireless aerial THINK
710234301 •
Programmable clip-in module THINK
710034502 •
Programmable external module THINK
710503704 •
Hot water temperature sensor
KHG 714076810 •
Remote control THINK
710244202 •
Remote control THINK (wireless)
710244302 •
Climate controller kit for mixing zones THINK
710519902 •
Interface kit for boilers in cascade THINK
710440802 •
Sensor for solar controller
LNC 710000040 •
* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244102 •) or the wireless aerial THINK (710234301 •)
42
Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 45-150 kW Description
Code
Outdoor sensor
KHG 714072811 •
Remote controller and climatic regulator
KHG 714072612 •
Boiler interface for mixing systems with two different temperatures zones
KHG 714077913 •
Bus interface for climatic regulators for boilers in cascade
KHG 714078013 •
Boiler control interface 0-10 V
KHG 714107612 •
Temperature regulator for mixing systems, it includes a temperature sensor
KHG 714078112 •
Cascade controller, it includes a temperature sensor
KHG 714078212 •
Room sensor: it can be installed only with climatic regulator for mixing system
KHG 714078410 •
Installation box for RVA controllers
KHG 714096610 •
Hot water temperature sensor for climatic regulator for boilers in cascade
KHG 714079010 •
Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 230-320 kW Description
Code
Outdoor sensor THINK
710487301 •
Interface kit for boilers in cascade
710440802 •
External tank sensor L=2 m
LSX 710000010 •
External tank sensor L=6 m
LSX 710000020 •
Accessory for managing mixing systems or solar panels
LSX 710000030 •
Climate controller kit for mixing zones THINK
710519902 •
LPG conversion kit: Luna Duo-tec MP Description
Code
LPG conversion kit for LUNA DUO-TEC MP 1.50
710718603 •
LPG conversion kit for LUNA DUO-TEC MP 1.60
710718702 •
LPG conversion kit for LUNA DUO-TEC MP 1.70
710718802 •
LPG conversion kit for LUNA DUO-TEC MP 1.90
710718902 •
LPG conversion kit for LUNA DUO-TEC MP 1.110
710719002 •
43
Accessories available as option Luna SAT WIRELESS data transmission
Code
Network node Network node with gateway Network node with gateway for transmission via GSM Remote reader device Software ACS 26 Connecting cable PC-network node for network note with gateway Wireless impulse adaptor AEW36.2
KSV 714102711 • KSV 714103011 • KSV 714102811 • KSV 714102911 • KSV 714108611 • KSV 714116110 • KSV 714117710 •
M-BUS data transmission
Code
Impulse adaptor AEW 310.2 M-BUS Connection cable heat meter M-BUS M-BUS central unit made of 250 loads M-BUS central unit made of 120 loads M-BUS central unit made of 60 loads M-BUS central unit made of 20 loads
KSV 714116210 • KSV 714116310 • KSV 714136910 • KSV 714137010 • KSV 714137110 • KSV 714137210 •
WIRELESS control
Code
First flow meter - mod. R/1-RP/1-R2Z - RPE - RPB First flow meter - mod. RS-RSP-RS2Z Second flow meter - mod. RP/1 Second flow meter - mod. R/1-R2Z - RPE - RPB Flow meter - mod. RA-RA2Z First or second flow meter - mod. RH -RH1- R2H First or second flow meter - mod. RPH First or second flow meter RHG1 1’’ First or second flow meter RHG1 3/4’’ Flow meter - Luna Sat RC
KSV 714102511 • KSV 714102611 • KSV 714106312 • KSV 714110111 • KSV 714110011 • KSV 714114511 • KSV 714114611 • KSV 714124910 • KSV 714125111 • KSV 714131310 •
M-BUS control
Code
First flow meter - mod. R/1-MB, RP/1-MB, R2Z-MB - RPE-MB, RPB - MB First flow meter - mod. RS-MB, RSP-MB, RS2Z-MB First or second flow meter - mod. RH-MB, RH1-MB, R2H-MB First or second flow meter - mod. RPH-MB Second flow meter - mod. RP/1-MB Second flow meter - mod. R/1-MB, R2Z-MB - RPE-MB, RPB-MB First or second flow meter RHG1-MB 1’’ First or second flow meter RHG1-MB 3/4’’ M-BUS flow meter - Luna Sat RC-MB
KSV 714116410 • KSV 714116510 • KSV 714116610 • KSV 714116710 • KSV 714118210 • KSV 714118310 • KSV 714125010 • KSV 714125210 • KSV 714134310 •
Thermoregulation
Code
Outdoor sensor Room thermostat (RT) Remote control and chronostat (mod. R2Z, RS, RSP, RS2Z, RA, RA2Z, RPE, RPEH - wireless and M-BUS) Digital chronostat (mod. R/1, RP1)
KHG 714072811 • KHG 714062810 • KSV 714109511 • KHG 714086711 •
44
Accessories available as option Luna SAT Other accessories
Code
Heat meter UH50 G1 ¼’’ Heat meter UH50 G2’’ Wireless interface UH50 for ultrasonic heat-meter
KSV 714117810 • KSV 714117910 • KSV 714121710 •
Well for NTC sensor (½” and ¾”) for UH50 G1 ¼”
KSV 714127310 •
Well for NTC sensor for UHG50 G2”
KSV 714127410 •
M-BUS interface UH50 for ultrasonic heat-meter
KSV 714121810 •
Complete template for Luna Sat RH1 By-pass for Luna Sat RC Heating hydraulic proof for Luna Sat RC
KSV 714122310 • KSV 714136310 • KSV 714136410 •
Sanitary hydraulic proof for Luna Sat RC
KSV 714136510 •
2L Sanitary expansion vessel for Luna Sat R60WH
soon available
GSM modem for DIN frame
KSV 714140810 •
Equipment (for all wireless/M-BUS models)
Code
Hydraulic equipment for Luna Sat heating only models R/1, RP/1, RH, RH1, RPH, RPB, RPE, R2H (x2), RPEH Hydraulic equipment for Luna Sat heating and DHW production model RS, RSP
KSV 714120911 • KSV 714121011 •
Hydraulic equipment for Luna Sat models R2Z, RA, RA2Z
KSV 714121110 •
Hydraulic equipment for Luna Sat heating / DHW production model RS2Z Hydraulic equipment for 2 flow meters for Luna Sat R/1, RP/1, RPB, RPE models Hydraulic equipment for 2 flow meters for Luna Sat RH, RPH, R2H. RPEH models
KSV 714121210 • KSV 714121310 • KSV 714121410 •
Mounting accessories
Code
Single zone case 2 zones case
KSV 714101211 • KSV 714101311 •
Case for RH 650x650 mm
KSV 714117011 •
Case for R2H
KSV 714120610 •
Case for RHG1
KSV 714124010 •
Case for RPH - RPEH Case for RC Case for RST
KSV 714124310 • KSV 714131010 • KSV 714141210 •
Cylinder
Code
Luna SAT B60 cylinder
KSV 71410841
45
Products technical data High efficiency condensing gas boilers
46
47
17,4
24,7
33
46,3
56,6
66,9
87,4
104,9
34,8
46,4
46,4
56,7
67
87,2
105
46,4
67
87,2
102,7
115
123,2
154
215
260
300
LUNA PLATINUM 1.18
LUNA PLATINUM 1.24
LUNA PLATINUM 1.32
LUNA DUO-TEC MP 1.50
LUNA DUO-TEC MP 1.60
LUNA DUO-TEC MP 1.70
LUNA DUO-TEC MP 1.90
LUNA DUO-TEC MP 1.110
LUNA HT 1.350
LUNA HT 1.450
LUNA HT 1.450 P
LUNA HT 1.550
LUNA HT 1.650
LUNA HT 1.850
LUNA HT 1.1000
POWER HT 1.450
POWER HT 1.650
POWER HT 1.850
POWER HT 1.1000
POWER HT 1.1150
POWER HT 1.1200
POWER HT 1.1500
POWER HT 1.230
POWER HT 1.280
POWER HT 1.320
kW
48
42
35
41,5
40
40
36,8
33,1
13,8
12,2
29,8
26,4
20
16
15
15
15
11,7
9,7
7,4
6,3
5,1
3,3
2,5
2,1
2,1
kW
12,4
MIN.
MAX.
Heat input
LUNA PLATINUM 1.12
PRODUCT
294
254,5
210,1
150
120
115
100
85
65
45
102
85
65
55
45
45
33,9
102
85
65
55
45
32
24
16,9
12
kW
MAX.
45,9
40,2
33,5
40,4
39
39
35,8
32,2
13,4
11,8
29
25,7
19,3
15,5
14,5
14,5
14,5
11,4
9,4
7,2
6,1
5
3,2
2,4
2
2
97,4
97,4
97,3
97,4
97,4
97,4
97,4
97,5
97,3
97,3
97,4
97,5
97,3
97,4
97,3
97,3
97,3
97,2
97,3
97,2
97,2
97,4
97,6
97,6
97,6
97,7
MIN. average temp. Pn 70°C kW %
Heat output
105,7
105,6
105,4
107,2
107,5
107,5
107,4
107,3
107,6
107,6
107,4
107,3
107,6
107,5
107,6
107,6
107,6
107,4
107,3
107,6
107,6
107,6
107,6
107,6
108
108
%
30%
92/42/EEC
98,1 98,1 98,0 97,8 97,8 97,9 97,8 97,9 97,9 97,9 98,0 97,9 98,1 98,0 97,9 97,9 98,1 98,0 98,0 98,0 98,0 97,9 98,0 98,0
★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★ ★★★★
1,7
1,7
1,7
2,0
2,0
2,0
2,0
1,9
2,1
2,1
2,0
1,9
2,1
2,0
2,1
2,1
2,1
2,2
2,1
2,2
2,2
2,0
1,9
1,9
2,6
2,5
2,5
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,5
0,5
0,5
0,0
0,0
0,0
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
0,1
61
61
61
75
77
72
80
78
75
75
74
75
75
78
74
74
72
74
75
76
96
92
80
80
75
9,3
9,3
9,3
8,7
8,7
8,7
8,7
8,7
8,9
8,7
8,7
8,7
8,7
8,7
8,7
8,7
8,7
9,2
9,0
9,0
9,0
9,0
9,0
9,0
9,0
★★★★
1,9
75
98,1
0,1
★★★★
0,5
%
1,8
9,0
CO2
98,2
burner
not working
★★★★
Maximum Output
stars combustion chimney radiating chimney flue number efficiency heat heat heat temp. 92/42/EEC losses losses losses max % % % % °C
Efficiency (Hi)
4,3
4,3
4,3
5,4
5,4
5,4
5,4
5,4
5,0
5,4
5,4
5,4
5,4
5,4
5,4
5,4
5,4
4,5
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
%
O2
26
26
26
34
34
34
34
34
31
34
34
34
34
34
34
34
34
27
30
30
30
30
30
30
30
30
0,136
0,118
0,097
0,073
0,058
0,054
0,049
0,041
0,031
0,022
0,050
0,041
0,032
0,027
0,022
0,022
0,016
0,047
0,040
0,031
0,026
0,021
0,015
0,011
0,008
0,006
57
57
57
58
58
55
57
56
55
55
55
55
55
55
55
55
55
55
55
55
59
58
55
55
55
55
exceeding flue flue air mass temp. and flow/rate max % kg/s °C
Maximum output
9,3
9,3
9,3
8,4
8,4
8,4
8,6
8,6
8,4
8,4
8,4
8,4
8,4
8,4
8,4
8,4
8,4
9,0
8,5
8,5
9,0
8,5
9,0
9,0
9,0
9,0
%
CO2
4,3
4,3
4,3
5,9
5,9
5,9
5,6
5,6
5,9
5,9
5,9
5,9
5,9
5,9
5,9
5,9
5,9
4,8
5,7
5,7
4,8
5,7
4,8
4,8
4,8
4,8
%
O2
Power consumption
26
26
26
39
39
39
36
36
39
39
39
39
39
39
39
39
39
30
38
38
30
38
30
30
30
30
0,021
0,019
0,016
0,020
0,019
0,019
0,018
0,016
0,007
0,006
0,015
0,013
0,010
0,008
0,007
0,007
0,007
0,005
0,005
0,004
0,003
0,002
0,002
0,001
0,001
0,001
410
350
330
235
135
128
160
100
110
900
200
150
125
80
175
75
45
320
275
210
210
190
130
120
110
95
-
-
-
-
-
-
-
-
-
-
-
-
-
-
100
-
-
170
165
125
120
115
75
75
75
75
exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W
Minimum Output
0085CL0072
0085CL0072
0085CL0072
0085BQ0055
0085BQ0055
0085BQ0055
0085BQ0055
0085BQ0055
0085BQ0055
0085BQ0055
0085BP0256
0085BP0256
0085BP0256
0085BP0256
0085BP0256
0085BP0256
0085BP0256
0085CM0128
0085CM0128
0085CM0128
0085CM0128
0085CM0128
0085CM0140
0085CM0140
0085CM0140
0085CM0140
Nr.
Certificate EEC
Products technical data – High efficiency condensing boilers
47
Quality Environment Safety
Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations
36061 BASSANO DEL GRAPPA (VI) - ITALY Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 03-12 (E)