COMMERCIAL_RANGE_03_13

Page 1

General catalogue COMMERCIAL AND TECHNICAL INFORMATION Commercial Range


Company Profile BAXI SPA has a proud tradition of developing and producing boilers and heating systems to the highest technological standards. For over 30 years BAXI SPA has provided a wide range of cutting-edge solutions, anticipating market evolutions and paying attention to customer needs.

How to read this catalogue In this catalogue we show the high efficiency condensing system complete range of BAXI products. On each page, in addition to the product benefits, there is a detailed list of the appliance characteristics, a technical chart, and coloured icons. These icons refer to the specific pages of the technical section of the catalogue where, by segment, the technical drawings and all the specific accessories are represented.

In the technical section you will find:

Dimensional Flue tube technical accessories drawings Graphs Flue systems

2

Hydraulic accessories

Thermoregulation accessories

Other accessories


High output condensing systems

More details and information on the website By accessing to the www.baxi.it, Reserved Area and then to the Tech Area, just after a quick registration it is possible to display and download the following documents:

• Certifications • Fault Finding List • General Catalogues • Instructions Manuals • PCB Service Instructions • Spare Parts Catalogues • Technical Drawings • Technical INFO • Technical presentations

Index

High output wall-hung condensing boilers

5

High output floor standing boilers

6

Built-in heat-boxes - Luna Sat

7

Luna Platinum 12 - 32 kW

9

Luna Duo-tec MP 50 - 110 kW

10

Modular heating system for Luna Duo-tec MP (GMC+1)

11

Power HT 45 - 150 kW

12

Power HT 230 - 320 kW

13

Power HT-A 430 - 650 kW

14

Luna Sat

15

Technical section

19

3


Condensing technology is the latest face in boiler innovation. By employing pre-mix burner know how, condensing boilers ensure higher performance (efficiency up to 109,8%) thanks to the recovery of all the heat available through combustion without wasting energy into the air, as happens with traditional boilers.

High efficiency installations Baxi condensing systems represent the ideal solution for installations where high outputs are required. The electronics platform of these boilers allows the control of single and cascade installations and a complete range of thermoregulation accessories.

High modulation ratio The new ranges of high efficiency condensing boilers are distinguished by a wider modulation ratio that grants a better efficiency thanks to reduced switch-on/ switch-off of the boiler.

Cutting edge electronics The sophisticated electronics of the high efficiency condensing boilers allows to manage single or cascade installation up to 16 boilers (Luna Duo-tec MP or Power HT 230-320). It is just needed to connect the relevant accessories to the boiler’s electronics.

Compact weight and dimensions Compact weight and dimensions of Baxi high efficiency condensing systems, guarantee the maximum flexibility and allow their installation also in small heat generator rooms. 4


High output condensing systems

High output wall hung boilers

Luna Platinum Luna Platinum 1.12/1.18 1.24/1.32

Maximum Heat Output

80째/60째 C

Luna Duo-tec MP 1.50

Luna Duo-tec MP 1.60

Luna Duo-tec MP 1.70

Luna Duo-tec MP 1.90

Luna Duo-tec MP 1.110

12/16,9 24/32

45

55

65

85

102

13,1/18,4 26,1/34,9

48,6

59,4

70,2

91,8

110,2

kW

Maximum Heat Output

50째/30째 C kW

5


High output floor standing boilers

Power HT

45-150 kW

230-320 kW

430-650 kW

Power HT 1.450 - 1.650 - 1.850 1.1000 - 1.1150 - 1.1200

Power HT 1.230 - 1.280 - 1.320

Power HT-A 1.430 - 1.500 - 1.570 - 1.650

Maximum Heat Output

Maximum Heat Output

Power HT

80°/60° C 50°/30° C Model

kW

kW

1.450

45

1.650

Maximum Heat Output

Maximum Heat Output

Power HT-A

80°/60° C 50°/30° C

Maximum Heat Output

Maximum Heat Output

80°/60° C 50°/30° C

Model

kW

kW

Model

kW

kW

48,7

1.230

210,1

229,8

1.430

392,8

422,4

65

70,3

1.280

254,5

278,1

1.500

462

498,2

1.850

85

91,6

1.320

294

321,3

1.570

531,4

574,6

1.1000

100

107,8

1.650

601

651,5

1.1150

112

121,1

1.1200

120

129,7

1.1500

150

162

6


High output condensing systems

Wireless and M-BUS built-in heat boxes Without pump (mixing valve)

With pump

To manage 2 zones

Heating only

Luna SAT RC - Luna SAT RC-MB Luna SAT R/1 - Luna SAT R/1-MB Luna SAT RH - Luna SAT RH-MB Luna SAT RH1 - Luna SAT RH1-MB Luna SAT RHG1 - Luna SAT RHG1-MB

Luna SAT RC - Rack

Luna SAT RP/1 - Luna SAT RP/1-MB Luna SAT RPH - Luna SAT RPH-MB Luna SAT RPB - Luna RPB-MB Luna SAT RPE - Luna SAT RPE-MB Luna SAT RPEH - Luna SAT RPEH-MB Luna SAT RP-SP-MB+2C

Luna SAT R2Z Luna SAT R2Z-MB

Combi Luna SAT RS - Luna SAT RS-MB Luna SAT RST-MB

Luna SAT RSP - Luna SAT RA Luna SAT RSP-MB Luna SAT R60 WH-MB (for wall hung installation with integrated cylinder)

Luna SAT RS2Z Luna SAT RA2Z

Heating and cooling

Luna SAT R2H - Luna SAT R2H-MB

- Luna Sat R/1, RH, RPB, RPE, RPEH, RH1 and RHG1 are available also with built-in flow-meters (M-BUS models as well) - RH1 and RH1-MB models are available also with pressure reducer on the flow-meters.

7


High output condensing systems

Thermal systems for cascade installations Wall hung boilers

Floor standing boilers

Wireless and M-BUS built-in heat boxes

- Luna Platinum - Luna Duo-tec MP - Modular heating system for Luna Duo-tec MP (GMC+)

- Power HT (outputs from 45 to 150 kW) - Power HT (outputs from 230 to 320 kW) - Power HT-A (outputs from 430 to 650 kW)

- Luna Sat-Heating only models - Luna Sat-Heating and DHW production models

88

10 11 12 15 16 16 17 18


High output condensing systems

Luna Platinum 12-32 kW

Technical pages 20-28 38-43

44

48

• Removable control panel for wall-hung installation with wide text display, regulation knob, menu selection buttons and back-lighting supplied with the boiler • Wide modulation ratio up to 1÷10: better efficiency thanks to reduced switch-on/switch-off of the boiler • Gas Adaptive Control (GAC) system: combustion automatic control to maintain constantly the highest level of efficiency • Integrated control of a solar system* • Complete soundproofing of the generator • Circulating pump with full modulation • Frontal access for advanced diagnostics

Hydraulic system 3 way electric diverter valve Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue heat exchanger Stainless steel enhaced DHW exchanger to ensure condensation also in DHW mode Modulating fan with electronic speed adjusting system Automatic by-pass Multi-speeds low energy pump of the heating circuit with built- in air vent System to prevent pump and diverter valve sticking operating every 24 hours Central relief valve set at 3 bar

Thermoregulation system Built-in climatic regulation (outdoor sensor available as optional) Control of multi-zones system option Cascade system installation option Room sensor, central heating and sanitary timers included in the control panel

Control system Overheat limit thermostat of the water/flue exchanger Hydraulic pressure switch to prevent boiler operating in event of low water Safety NTC sensor against flues overheat Electronic temperatures control by NTC sensors Full anti-frost device Electronic thermometer Digital central heating pressure gauge

Outputs from 12 to 32 kW Product code

1.12

1.18

1.24

1.32

7102665

7108435

7106583

7108436 33

Maximum heating heat input

kW

12,4

17,4

24,7

Maximum heating heat output 80/60°C

kW

12

16,9

24

32

Maximum heating heat output 50/30°C

kW

13,1

18,4

26,1

34,9

Minimum heating heat output 80/60°C

kW

2

2,4

2,4

3,2

Minimum heating heat output 50/30°C

kW

2,2

2,7

2,7

3,5

Energetic efficiency (92/42/CEE)









Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,8

97,7

97,6

97,6

Nominal efficiency 50/30°C

%

105,8

105,8

105,7

105,7

Efficiency 30%

%

107,8

107,7

107,6

107,6

5

5

5

5

-5

-5

-5

-5

NOx class (EN 483) Minimum working temperature Expansion vessel capacity/pre-charge

°C l/bar

8/0,8

8/0,8

8/0,8

10/0,8

Heating temperature range.

°C

25/80

25/80

25/80

25/80

Maximum pressure heating circuit

bar

3

3

3

3

m

10

10

10

10

Coaxial flue system Ø 60/100 max length

m

80

80

80

80

Maximum flue mass flow rate

Dual flue system Ø 80 max length

kg/s

0,006

0,008

0,012

0,016

Minimum flue mass flow rate

kg/s

0,001

0,001

0,001

0,002

Maximum flue temperature

°C

75

75

80

80

Dimensions (h x w x d)

mm

Net weight

kg

34,5

34,5

760 x 450 x 345

Gas type Power consumption Grade of protection

34,5

37,5

Natural Gas/LPG W

108

122

120

130

IPX5D

IPX5D

IPX5D

IPX5D

*in case of contemporary control of a solar system and a zone by the wallmounted control panel, it is necessary to install a programmable clip in/external module THINK.

9


Technical pages 21-30 38-43

Luna Duo-tec MP 50-110 kW

45

48

• Stainless steel AISI 316L single chamber (50 – 60 – 70 kW) and double chamber (90 – 110 kW) exchanger: high output in compact size, reliability and long life. • High modulation ratio (1÷9): better efficiency thanks to reduced switch-on/switch-off of the boiler • Digital control panel with push buttons and wide LCD display (numbers and symbols) • Compact size and minimal weight • Complete range of accessories for single and cascade installations

Outputs from 50 to 110 kW Hydraulic system Modulating pump included in the boiler System to prevent pump sticking operating every 24 hours Flow and return NTC sensors Water tray for condensate drain from supply air duct

Thermoregulation system Built-in climatic regulation (outdoor sensor supplied as optional) Mixed zones systems (high and low temperatures) installation option Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW timers integrated in the control panel

Control system Full electronic anti-frost device Electronic thermometer Central heating pressure gauge Flow over-temperature thermostat

Product code

1.50

1.60

1.70

1.90

1.110

7104050

7104051

7104052

7104651

7104652

Maximum heating heat input

kW

46,3

56,6

66,9

87,4

104,9

Maximum heating heat output 80/60°C

kW

45

55

65

85

102

Maximum heating heat output 50/30°C

kW

48,6

59,4

70,2

91,8

110,2

Minimum heat output 80/60°C

kW

5

6,1

7,2

9,4

11,4

Minimum heat output 50/30°C

kW

5,4

6,6

7,8

10,2

12,3

Energetic efficiency 92/42/CEE

HHHH

HHHH

HHHH

HHHH

HHHH

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,2

97,2

97,2

97,2

97,2

Nominal efficiency 50/30°C

%

105

105

105

105

105

Efficiency at 30%

%

107,8

107,4

107,1

107,5

107,4

5

5

5

5

5

NOx class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

-5

Water content

lt

4

5

6

9

10

Heating system max pressure

bar

4

4

4

4

4

Safety valve intervention pressure

bar

4

4

4

4

4

Regulation of water temperature in heating circuit

°C

25/80

25/80

25/80

25/80

25/80

Coaxial flue system max length

m

10 (Ø 80/125)

10 (ø 80/125)

10 (ø 80/125)

10 (ø 110/160)

10 (ø 110/160)

Dual flue system max length

m

60 (ø 80)

60 (ø 80)

60 (ø 80)

27 (ø 110)

27 (ø 110)

Maximum flue mass flow rate

kg/s

0,021

0,026

0,031

0,04

0,047

Minimum flue mass flow rate

kg/s

0,002

0,003

0,004

0,005

0,005

Maximum flue temperature

°C

80

80

74

70

70

Dimensions (h x w x d)

mm

766x450x377

766x450x377

766x450x505

952x600x584

952x600x584

Net weight

kg

40

40

50

83

93

Nat. gas/LPG

Gas type Power consumption Grade of protection

10

W

190

210

210

275

320

IPX5D

IPX5D

IPX5D

IPX5D

IPX5D


High output condensing systems Technical pages

Modular heating system W E N for Luna Duo-tec MP (GMC+)

22

• Solutions with 1,2,3 doors cabinet • Compact cabinet: 175 cm height • Hydraulic separator can be assembled inside the cabinet • Insulated hydraulic collectors sustained by fixing brackets • Built-in condensate tray

CABINET made of:

N° of installed Boilers

1.50 1.60 1.70

1

door*

Hydraulic system Hydraulic connections between boilers and copper collectors Integration of the hydraulic safety accessories

2

LUNA DUO-TEC MP possible configuration

1.90 1.110

Tot. installed kW

50 60 90 110

or

1.50 1.60 1.70 1.90 1.110

From 50 kW to 220 kW

or

1.50 1.60 1.70 1.90 1.110

From 50 kW to 330 kW

doors*

Expansion vessels included Flow/return right or left side possibility

3

doors*

* to install the hydraulic compensator and the system accessories sheltered from the bad weather it is possible to order an additional cabinet

11


Power HT 45-150 kW

Technical pages 23-32 38-44

47

48

• Stainless steel double chamber exchanger: high output in compact size, reliability and long life • Digital control panel “advanced CPS system” with push buttons and wide LCD display with text and symbols • Complete range of temperature regulation accessories • Minimal weight and size • Complete range of accessories for single and cascade installations

Outputs from 45 to 150 kW

Hydraulic system Stainless steel AISI 316L premixing burner Stainless steel AISI 316L water/flue exchanger System to prevent pump sticking operating every 24 hours

Thermoregulation system Remote controller and climatic regulator (supplied as optional) Built-in weather compensation function (outdoor sensor supplied as optional) Mixed zones systems (low and high temperature) installation option Cascade system installation option NTC sensor for DHW cylinder control option

Control system Central heating and indirect cylinder timer Hydraulic pressure switch to prevent boiler operating in event of low water Full electronic anti-frost device Electronic thermometer Central heating pressure gauge

1.450 Product code

WHS

1.650

1.850

1.1150

1.1200

1.1500

43104560 43106560 43108560 43110060 43111260 43112060 43115060

Maximum heating heat input

kW

46,4

67

87,2

102,7

115

123,2

154

Maximum heating heat output 80/60°C

kW

45

65

85

100

112

120

150

Maximum heating heat output 50/30°C

kW

48,7

70,3

91,6

107,8

121,1

129,7

162

Minimum heat output 80/60°C

kW

11,8

13,4

32,2

35,8

39

39

40,4

Minimum heat output 50/30°C

kW

12,8

14,5

34,9

38,8

42,1

42,1

43,7

Energetic efficiency 92/42/CEE

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

Average efficiency (DIN 4702-T8)

%

109,8

109,8

109,8

109,8

109,8

109,8

109,8

Nominal efficiency 80/60°C

%

97,3

97,3

97,5

97,4

97,4

97,4

97,4

Nominal efficiency 50/30°C

%

105,2

105,3

105,1

105

105,3

105,3

105,2

Efficiency at 30%

%

107,6

107,6

107,3

107,4

107,5

107,5

107,2

5

5

5

5

5

5

5 -5

NOx class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

-5

-5

Safety valve intervention pressure

bar

3

3

3

3

3

3

3

Heating system max pressure

bar

4

4

4

4

4

4

4

Regulation of water temperature in heating circuit

°C

25/80

25/80

25/80

25/80

25/80

25/80

25/80

Primary circuit water flow (ΔT=20°C)

l/h

1.935

2.795

3.700

4.300

4.800

5.200

6.500

l

5,1

6,5

13,7

21

23,3

23,3

25,3

ø mm

80

80

100

100

100

100

100

Water content Flue tube

m

30

20

20

20

20

20

20

Maximum flue mass flow rate

Flue ducts max length

kg/s

0,022

0,031

0,041

0,049

0,054

0,059

0,073

Minimum flue mass flow rate

kg/s

0,006

0,007

0,016

0,018

0,019

0,019

0,02

Maximum flue temperature

°C

72

73

78

80

72

77

75

Dimensions (h x w x d)

mm

850x450x621

850x450x693

850x450x801

850x450x871

850x450x1024

850x450x1024

850x450x1132

kg

60

68

75

83

95

95

103

128

135

235

Net weight Gas type Power consumption

12

1.1000

Nat. gas/LPG W

90

110

100

160


High output condensing systems Technical pages 25-32

Power HT 230-320 kW

42

48

50

• Aluminium-Silicon exchanger with glass wool insulation: high efficiency and reliability and long life • Modulation ratio (1÷6) • Low emissions pre-mixing burner • Digital control panel with back-lighted LCD display and advanced electronics to manage single and cascade installations • Easy to transport and to install • Low noise operational

Outputs from 230 to 320 kW

Hydraulic system Hydraulic connections on the rear side Sticking pump check system Flow and return NTC sensors Premixed low-emissions burner

Thermoregulation system Built-in climatic regulation (outdoor sensor included) Mixed zones systems (high and low temperatures) zone controllers as optional Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW scheduler integrated in the control panel

Control system Full electronic anti-frost device Electronic thermometer Flow over-temperature thermostat

Power HT 1.230

Power HT 1.280

Power HT 1.320

Product code

LSX

411230600 .

411280600 .

411320600 .

Nominal heat output

kW

215,0

260,0

300,0

Maximum heating heat output 80/60°C

kW

210,1

254,5

294,0

Maximum heating heat output 50/30°C

kW

229,8

278,1

321,3

Minimum heat output 80/60°C

kW

33,5

40,2

45,9

Minimum heat output 50/30°C

kW

37,4

44,9

51,4

Energetic efficiency 92/42/CEE







Average efficiency (DIN 4702-T8)

%

109,6

109,7

109,7

Nominal efficiency 80/60°C

%

97,9

98,0

98,0

Nominal efficiency 50/30°C

%

106,9

107,0

107,1

Efficiency at 30%

%

105,4

105,6

105,7

5

5

5

NOx Class (EN 483) Minimum working temperature

°C

-5

-5

-5

Heating system max pressure

bar

6

6

6

Water content

lt

38

45

53

Flue ducts max length

m

60 (Ø200)

60 (Ø200)

60 (Ø200)

Maximum flue mass flow rate

kg/s

0,097

0,118

0,136

Minimum flue mass flow rate

kg/s

0,016

0,019

0,021

Maximum flue temperature

°C

61

60

60

Dimensions (h x w x d)*

mm

1458x692x1231

1458x692x1324

1458x692x1417

Net weight

kg

285

314

344

Gas type Power consumption

Natural Gas / LPG W

330

350

410

(*) Flue ducts and hydraulic pipes included

13


Technical pages 27-33 37-38

Power HT-A 430-650 kW NEW

43

• Aluminium-Silicon exchanger with glass wool insulation: high annual efficiency, reliability and long life • Modulation ratio (1÷5) • Digital control panel with back-lighted LCD display and advanced electronics to manage single and cascade installations • Easy to transport and to install • Low noise operational

Outputs from 430 to 650 kW

Hydraulic system Hydraulic connections on the top side Sticking pump check system Flow and return NTC sensors Premixed low-emissions burner

Thermoregulation system Built-in climatic regulation (outdoor sensor included) Mixed zones systems (high and low temperatures) zone controllers as optional Cascade system installation option (up to 16 boilers) NTC sensor for DHW cylinder control option Heating and DHW scheduler integrated in the control panel

Control system Full electronic anti-frost device Electronic thermometer Flow over-temperature thermostat

Power HT 1.430

Power HT 1.500

Power HT 1.570

Power HT 1.650

Product code

LSX

411430600 .

411500600 .

411570600 .

411650600 .

Nominal heat output

kW

400

470

540

610

Maximum heating heat output 80/60°C

kW

392,8

462

531,4

601

Maximum heating heat output 50/30°C

kW

422,4

498,2

574,6

651,5

Minimum heat output 80/60°C

kW

77

91

105

119

Minimum heat output 50/30°C

kW

84,8

99,8

115

130,4

Energetic efficiency 92/42/CEE









Average efficiency (DIN 4702-T8)

%

109,4

109,3

109,2

109,1

Nominal efficiency 80/60°C

%

98,2

98,3

98,4

98,5

Nominal efficiency 50/30°C

%

105,6

106

106,4

106,8

5

5

5

5

NOx Class (EN 483) Minimum working temperature

°C

-5

-5

-5

-5

Heating system max pressure

bar

6

6

6

6

lt

73

84

97

106 60 (Ø250)

Water content Flue ducts max length

m

60 (Ø250)

60 (Ø250)

60 (Ø250)

Maximum flue mass flow rate

kg/s

0,188

0,22

0,253

0,286

Minimum flue mass flow rate

kg/s

0,038

0,044

0,05

0,057

Maximum flue temperature

°C

60

60

60

60

Dimensions (h x w x d)*

mm

1526x762x1882

1526x762x2192

1526x762x2192

1526x762x2192

Net weight

kg

540

598

636

674

790

750

Gas type Power consumption (*) Flue ducts and hydraulic pipes included

14

Natural Gas / LPG W

463

583


High output condensing systems

Luna Sat-Heating only models

Technical pages

51

34

Models without pump

RC: KSV 71413111 RC-MB: KSV 71413121

R/1: KSV 71411151 R/1-MB: KSV 71411541

RHG1: KSV 71412361 RHG1-MB: KSV 71412371

Heating circuit maximum pressure Water contents

RH: KSV 71411321 RH-MB: KSV 71411591

RH1: KSV 71411811 RH1-MB: KSV 71411851

R2H: KSV 71412041 R2H-MB: KSV 71412051

RC

R/1

RH

RH1

RHG1

bar

4

4

4

4

4

R2H** 4

I

0,5

1,5

1,5

1,5

2

1,5 230

Power supply voltage

V

230

230

230

230

230

Power supply frequency

Hz

50

50

50

50

50

50

Power consumption

W

15

15

15

15

15

15

Width of the case

mm

450

600

650

400*

500

800

Height of the case

mm

450

650

650

600*

850

750

Depth of the case

mm

110

150

150

200*

150

150

Net weight

Kg

3,2

11

11

9

13

9

Maximum temperature of the warm fluid (inlet)

°C

90

90

90

90

90

90

Feed flow (inlet)

l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

Flow-losses

kPa

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps (**) For heating and cooling

15


Technical pages

Luna Sat-Heating only models

51

34

Models with pump

RP/1: KSV 71411161 RP/1-MB: KSV 71411551

RPH: KSV 71411331 RPH-MB: KSV 71411601

RPB: KSV 71411171 RPB-MB: KSV 71411581

NEW

RPE: KSV 71411911 RPE-MB: KSV 71411921

RPEH: KSV 71412451 RPEH-MB: KSV 71412461

RP-SP-MB + 2C:

KSV 71414401

RP/1

RPH

RPB

RPE

RPEH

RP-SP-MB+2C

Models with pump

R2Z •

Models with 2nd zone

-

-

-

-

-

-

25/80

Heating temperature regulation with high climatic curve

°C

-

-

-

25/80

-

-

Heating circuit maximum pressure

bar

4

4

4

4

4

4

4

I

2

2

2

2

2

9,5

3,5 230

Water contents Power supply voltage

V

230

230

230

230

230

230

Power supply frequency

Hz

50

50

50

50

50

50

50

Power consumption

W

110

110

110

110

110

110

210

Width of the case

mm

600

600*

600

600

600

600

800

Height of the case

mm

650

716*

650

650

850

850

750

Depth of the case

mm

150

150*

150

150

150

150

150

Net weight

Kg

13

13

12

13,50

14

17

22

Maximum temperature of the warm fluid (inlet)

°C

90

90

90

90

90

90

90

Feed flow (inlet)

l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

700÷ 1000 l/h

Flow-losses

kPa

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

(*) The case can not be used. Measures are referred to RPH and RH1 models without casing including interception taps

Model to manage 2 different zones R2Z: KSV 71410101 R2Z-MB: KSV 71411901 16


High output condensing systems Technical pages

Luna Sat-Heating and DHW production models

RSP: KSV 71410091 RSP-MB: KSV 71411571

RA: KSV 71410771

RS2Z: KSV 71410111

RA2Z: KSV 71410781

51

34

R60WH-MB KSV 71413071

RST-MB: KSV 71413971

RSP

RS2Z

RA

R60WH

RA2Z

RST

DHW production

Models with pump

-

Models with 2nd zone

-

-

-

-

Heating temperature regulation with high climatic curve

°C

25/80

25/80

25/80

25/80

25/80

25/80

DHW regulation

°C

30/60

30/60

30/65

30/65

30/65

30/60

DHW production with ∆T=35°C and inlet water temperature 75°C

l/m

14,3

14,3

14,3

14,3

14,3

14,3

Heating circuit maximum pressure

bar

4

4

4

4

4

4

DHW circuit maximum pressure

bar

8

8

8

8

8

8

DHW circuit minimum pressure

bar

0,2

0,2

0,2

0,2

0,2

0,2

Water contents

l

2,5

4

2

5

4

2

Power supply voltage

V

230

230

230

230

230

230

Power supply frequency

Hz

50

50

50

50

50

50

Power consumption

W

110

210

150

110

210

15

Width of the case

mm

600

800

600

910

800

600

Height of the case

mm

650

750

650

450

750

600

Depth of the case

mm

150

150

150

473

150

150

Net weight

Kg

18

28

16

38

25

16

Maximum temperature of the warm fluid (inlet)

°C

90

90

90

90

90

90

Feed flow (inlet)

l/h

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

1000÷ 1500

Flow-losses

kPa

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

20Kpa at 700 l/h

17


Technical pages

Luna Sat RC in Rack NEW

• Up to 3 flow meters for each Luna Sat RC installation option • Insulated hydraulic manifolds available as option

RC Heating circuit maximum pressure

bar

4

l

0,5

Power supply voltage

V

230

Power supply frequency

Hz

50

Power consumption

W

15

Width of the case

mm

450

Height of the case

mm

450

Depth of the case

mm

110

Net weight

Kg

3,2

Water content

DIMENSIONS 4 modules Rack

MR1-MR2-MR3 = apartment heating flow RR1- RR2 - RR3 = apartment heating return UC1 - UC2 - UC3 = heat meter outlet 1 - 2 - 3 to the apartment IP = primary inlet from centralized system UP = primary outlet to the centralized system EC1 = inlet to the first heat meter

MR1-MR2-MR3 = apartment heating flow RR1- RR2 - RR3 = apartment heating return UC1 - UC2 - UC3 = heat meter outlet 1 - 2 - 3 to the apartment IP = primary inlet from centralized system UP = primary outlet to the centralized system EC1 = inlet to the first heat meter system

AE = hole for cables

AE = hole for cables

18

51

• Parallel assembly of 3 or 4 Luna Sat RC or RC-MB option

• Built-in taps in the casing

3 modules Rack

34


High output condensing systems

Technical Section

Technical drawings Graphs Flue systems

20

Flue pipes accessories

37

Hydraulic accessories

44

Thermoregulation accessories

48

Other accessories

51

Products technical data

53

19


High output condensing system Luna Platinum 1.12-1.18-1.24-1.32 140,5

131min.

177

M.B.

760

450

S.C. M.R. M.B. GAS E.S. R.R.

Condensing trap that can be installed on a Ø 21 pipe Heating system flow G 3/4” Storage tank flow G 3/4” Gas inlet G 3/4” Mains water G 1/2” Heating system return G 3/4”

6 5,5 5 4,5 4 3,5 3 2,5 2 1,5 1

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

FLOW RATE/HEAD CURVE

Flues temperature %

HEAD

345

MAX MIN

0

200

400

800

600

1000

1200

1400

FLOW RATE (l/h)

Efficiency of the boiler %

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

20

108 107 106 105 104 103 102 101 100 99 98 97

30% load 100% load

30

35

40

45

50

Return temperature of the system °C

55

60

75 70 65 60 55 50 45 40 35 30

100% load

30% load

30

35

40

45

50

Return temperature of the system °C

55

60


Technical drawings - graphs - flue systems

High output condensing system Luna Duo-tec MP

Luna Duo-tec MP 1.90-1.110

������������������� 1.50-1.60-1.70 450 225

(A)

140

223 952

229

763

225

600 354,5

584 245,5

112

(A) 377 mm Mod. 1.50-1.60 505 mm Mod. 1.70 Coaxial flue system ø 80/125 Dual flue system ø 80

GAS

M.R.

R.R.

Gas inlet G ¾” Heating system flow (G1”) with cylinder connection option Heating system return (G1”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe

S.C

GAS

M.R.

R.R.

HEAD (mH2O)

HEAD (mH2O)

HEAD (mH2O)

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.90

FLOW RATE (l/h)

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.110

EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

Efficiency of the boiler %

FLOW RATE (l/h)

HEAD (mH2O)

Gas inlet G 1” Heating system flow (G1-G1/2”) with cylinder connection option Heating system return (G1-1/2”) with cylinder connection option Condensing trap that can be installed on a Ø 21 pipe

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.70

FLOW RATE/HEAD CURVE LUNA DUO-TEC MP 1.50 - 1.60

FLOW RATE (l/h)

ø 110/160 ø 110 GAS M.R. R.R. S.C.

108 107 106 105 104 103 102 101 100 99 98 97

FLOW RATE (l/h)

30% load 100% load

30

35

40

45

50

FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

Flues temperature %

S.C

GAS M.R. R.R. S.C.

Coaxial flue system Dual flue system

55

Return temperature of the system °C

60

75 70 65 60 55 50 45 40 35 30

100% load

30% load

30

35

40

45

50

55

60

Return temperature of the system °C

21


High output condensing system 216

O 149

1750

Modular heating system for Luna Duo-tec MP (GMC+) - 1 door 417

260

120

216

O 149

128 314

205 800

281

1750

216

O 149

401,5

456

347

120

310

193

401,5 417

128 O 149314

281

D

1750

800

310

417

up view

347

260

456

H

803

120

401,5

W

1 door

193

401,5

205 800

side view

216

frontal view

1750

260

Dimensions (mm) Modules

128 314

1600

205 800

281

1750

Modular heating system for Luna Duo-tec MP (GMC+) - 2 doors 401,5417

456

401,5

347

193

800

260

310

800

120

O 149

216

216

O 149

128 314

456

401,5

O 149

193

417

260

260 128 314

1600

216

456

401,5

205 800 O 149

800 456

Modules

281

W

H

D

2 doors

1600

1750

800

Luna Duo-tec MP 90-110 347 800

347

193

310

193

401,5 800

Dimensions (mm)

205 128281 314 800

side view

frontal view 800 401,5

347

120

120

310 1600

800

216

800 417

310

281

1750

401,5

401,5

205 800

Luna Duo-tec MP 50-60-70

1750

1750

1600

2400

1750

Modular heating system for Luna Duo-tec MP (GMC+) - 3 doors

401,5

O 149

800

800

401,5

193 120 260

216

310

417

128 314

2400

205 800

281

1750

Luna Duo-tec MP 50-60-70 401,5

800

800

401,5

456

800

800

260

120

310

193

417

128 314

2400

22

Dimensions (mm) 401,5

800

W

H

D

3 doors

2400

1750

800

310

Modules

800

401,5

456

193

347

281

Luna Duo-tec MP 90-110

side view

frontal view 800

205 800

800

800

347

347


Technical drawings - graphs - flue systems

High output condensing system Power HT 45-150 kW Placement RVA

Power HT

FLOW RATE/HEAD CURVE

Power HT To allow an easy access for the boiler maintenance, the minimum recommended distance must be observed

HEAD (mH2O)

Depth (A) mm

FLOW RATE (l/h)

45 cm

45 cm/ 2 cm

EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS

45 cm/ 2 cm

FLOW RATE (l/h) EXCHANGER PRESSURE LOSS EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS (mH2O)

EXCHANGER PRESSURE LOSS

FLOW RATE (l/h)

FLOW RATE (l/h)

23


High output condensing system

186,5

936,5

136,5

800

Power HT 45-150 kW

20 * 450

450

20* 450

436,5

(*) - The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used. Flow/return manifolds squared 100x100 with flanges DN80 PN6 24


Technical drawings - graphs - flue systems

High output condensing system Power HT 230-320 kW

Flow

Flange

Return Flange

Power HT

1.230

1.280 1.320

Depth (A) mm

1.269

1.362 1.452

HEAT PRODUCTION ACCORDING TO THE OUTDOOR TEMPERATURE

80 R 0 23 .2 E 1. T 1 OW HT R H P ER E W OW PO P

0

32

1.

Characteristic curve

Hea

ting

flow

Heati

Dew point = 54째C

ng re

turn

100

Outdoor temperature 째C 10

EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT

1 1

0

1

FLOW RATE [m3/h]

100

Efficiency%

WATER SIDE RESISTANCE (mbar)

1000

HT

Heating water temperature

EXCHANGER PRESSURE LOSSES

Output %

25


High output condensing system Power HT 230-320 kW

A

B

1 Remove lower rear wall (2) of the Power HT

Side supply air connection (A)

Rear supply air connection (B)

2 Remove the gas connection leading upward

1 Remove lower rear wall (3)

1 Remove lower rear wall (2)

2 Remove the covering panel (2)

2 Take out cover plate (3)

3 Turn 87°bend (1) in the desired position

3 Mount the bend of the intake pipe (1)

3 Mount straight intake pipe

4 Turn intake pipe elbow into the side position (1)

4 Mount lower rear wall (2)

and insert a 87°bend (1) (side or towards the rear)

4 Remove either the rear cover plate (3) or the

5 Mount lower rear wall (3)

side cover plate (4)

5 Mount lower rear wall (2)

Max lengths for the flue pipes with room air dependent working (type B installation)

Model

Power HT 1.230

Power HT 1.280

Power HT 1.320

Flue pipe - ø

mm

200

200

200

Max L. pipe inc. 87° bend

mm

60

60

60

These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m 1 piece 45° bend: 2 m 1 piece 15° bend: 1 m

26


Technical drawings - graphs - flue systems

Flue system

F

Power HT-A (430-650 kW)

F

G

Power HT-A (dimensions)

Power HT-A

1.430

1.500 1.570

1.650

Depth (D) mm

1.882

2.192 2.192

2.192

1.430

1.500

1.570

1.650

A

mm

642

642

642

642

B

mm

798

1009

1009

1009

C

mm

442

540

540

540

D

mm

1882

2192

2192

2192

E

mm

709

1018

1018

1018

F

mm

1526*

1526*

1526*

1526*

G

mm

762

762

762

762

* flue ducts and hydraulic pipes included

HEAT PRODUCTION ACCORDING TO THE OUTDOOR TEMPERATURE

Hea

ting

flow

Dew point = 54째C

Heati

ng re

EXCHANGER PRESSURE LOSSES

turn

600

Heating water temperature

Characteristic curve

550 500

Outdoor temperature 째C

400

EFFICIENCY OF THE BOILER ACCORDING TO THE OUTPUT

POWER HT-A 1.430

350

POWER HT-A 1.500

300 250

POWER HT-A 1.650

200

Efficiency%

WATER SIDE RESISTANCE (mbar)

450

POWER HT-A 1.570

150 100 50 0

0

5

10

15

20

25

30

35

FLOW RATE [m3/h]

40

45

50

55

Output %

27


Coaxial flue system Luna Platinum

450

345

frontal view

side view

Example of installation with horizontal flue system Ø 60/100 and Ø 80/125

Tubes maximum length (m)

Installation examples with LAS chimney Ø 60/100 and Ø 80/125

Ø 60/100

Ø 80/125

10

25

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

1

0,5

Installation example with vertical coaxial flue ducts Ø 60/100 and Ø 80/125

Vertical chimney terminal for coaxial flue system

Ø 126

130

50

Ø 81,5

Ø 60 Ø 100

.

KHG 714093510 Vertical chimney terminal for coaxial flue system Ø 60/100

28

.

KHG 714093910 Reduction from Ø 80/125 to Ø 60/100


Technical drawings - graphs - flue systems

Dual flue system Luna Platinum

frontal view

side view

Example of installation with vertical dual flue system

frontal view

side view

Installation example with horizontal dual flue ducts

Intake pipe maximum length: 15 m.

Vertical chimney terminal for dual flue system

50

200

138

Ø 126

Ø 80

.

KHG 714093510 Vertical chimney terminal Ø 80/125

.

KHG 714093810 Dual flue pipes adapter for coaxial chimney (Ø 80/80 to Ø 80/125)

29


Flue system – Coaxial flue system Luna Duo-tec MP Type of duct

Tubes maximum length (m)

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

Ø chimney terminal (mm)

Ø external duct

Coaxial Ø 110/160 mm

10 m

1m

0,5 m

163 mm

160 mm

Vertical dual flue system

15 m

0,5 m

0,25 m

163 mm

110 mm

Coaxial Ø 85/125 mm

10 m

1m

0,5 m

133 mm

125 mm

Vertical dual flue system

15 m

0,5 m

0,25 m

133 mm

80 mm

Horizontal dual flue system*

60 m

0,5 m

0,25 m

-

80 mm

* intake pipe maximum length: 15 m.

COAXIAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80/125 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110/160 mm

DUAL FLUE SYSTEM Luna Duo-tec MP 1.50 - 1.60 - 1.70 = Ø 80+80 mm Luna Duo-tec MP 1.90 - 1.110 = Ø 110+110 mm

Luna Duo-tec MP – Coaxial flue system Installation example with coaxial flue ducts Ø 80/125 (mod. 1.50 - 1.60 - 1.70) and Ø 110/160 (mod. 1.90 - 1.110)

30


Technical drawings - graphs - flue systems

Dual flue system Luna Duo-tec MP 1.50 - 1.70

Luna Duo-tec MP 1.90 - 1.110

Installation example with horizontal dual flue ducts

Intake pipe maximum length: 15 m

Example of installation with vertical dual flue system

31


Flue system Power HT (45-150 kW) – Flue pipe

Model

Tubes maximum length (m)

Length reduction for a 90° bend insertion (m)

Length reduction for a 45° bend insertion (m)

30 20 20 20 20 20 20

1 1 1 1 1 1 1

0,5 0,5 0,5 0,5 0,5 0,5 0,5

HT 1.450 HT 1.650 HT 1.850 HT 1.1000 HT 1.1150 HT 1.1200 HT 1.1500

Power HT (230-320 kW) – Flue/Intake pipes

flow flange DN 65

return flange DN 65

Ø flue pipe Tube maximum length including 1 87° bend (m)

Power HT 1.230

Power HT 1.280

Power HT 1.320

mm

200

200

200

mm

60

60

60

These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m

32


Technical drawings - graphs - flue systems

Flue system Power HT-A 430-650 kW - Flue / Intake pipes

B

E

D

F

G

A C

Power HT-A

1.430

1.500

1.570

MR Heating flow

Flange DN 80 PN 6

RR Heating return

Flange DN 80 PN 6

Gas Gas outlet

R2" external threaded

A Rear flue outlet (optional)

DN 250

B Provided rear supply air connection

nom. diam. 160

C Condensated water connection (right or left)

DN 32

D Safety hydraulic group connection

R¾" external threaded

E Safety valve connection

R2" external threaded

F Provided top flue connection

DN 250

G Side supply air inlet (optional)

nom. diam. 160

Ø flue pipe Tube maximum length including 1 87° bend (m)

1.650

Power HT-A 1.430

Power HT-A 1.500

Power HT-A 1.570

Power HT-A 1.650

mm

250

250

250

250

mm

50

50

50

50

These lengths are only for single boilers Decrease of the total lengths of the flue pipes: 1 piece 87° bend: 5 m - 1 piece 45° bend: 2 m - 1 piece 15° bend: 1 m

33


Luna Sat

dimensions in mm

Model: Luna Sat RC

85 RR

70 70 70 45

USC 2 USC 1

USC1: water outlet from first heat meter G 3/4 “ M USC2: water outlet from second heat meter G 3/4 “ M USC3: water outlet to third heat meter G 3/4 “ M

42

USC 3

42 68

L of the casing 450

DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M ESC3 : cold water inlet to third heat meter G 3/4 “ M

450

View from below

ESC 3

77 33 right side view

Frontal view

ESC 1 ESC 2

dx

UP

sx

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

IP

MR

110

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

110 left side view

Models: Luna Sat R/1 - RP/1 - RPB - RPE - RSP - RA

Screws seats

Connection tongues

L of the casing 600

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

(A)

DHW CONSUMPTION METER CONNECTIONS ES: Cold water inlet G 1/2 “ M ( RSP mod.) US: DHW outlet G 1/2 “ M ( RSP mod.) ESC1: cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M

Equiment of the case

View from A

CENTRALIZED SYSTEM CONNECTIONS- in case of high temperature zones MRAT: high temperature zone G 1/2’’ M apartment flow RRAT: high temperature zone G 1/2’’ M apartment return

Insert the final part of the pipes inside the case

left side view

Frontal view

Models: Luna Sat R2Z - RS2Z - RA2Z

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

Connection tongues

Screws seats

L of the casing 800

HEATING SYSTEM CONNECTIONS – BIZONE MODELS MRAT: high temperature zone G 3/4’’ M apartment flow MRBT: low temperature zone G 3/4’’ M apartment flow RRAT: high temperature zone G 3/4’’ M apartment return RRBT: low temperature zone G 3/4’’ M apartment return DHW CONSUMPTION METER CONNECTIONS ES: water inlet to the first heat meter G 1/2 “M US: water outlet to the first heat meter G 1/2 “ M ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M AE: hole for cables

(A) Equiment of the case

View from A

Insert the final part of the pipes inside the case

left side view

Frontal view

The uprights of the centralized network can be intercepted also by lateral sides of the case Model: Luna Sat RH

Case width 150

Casing height 650

(A)

L of the case 650

Connection kit 30

Screws seats

Upper view from A

Frontal view

Left side view

The holes for hydraulic connections are on all sides of the casing

34

USC1 USC2

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M USC1: water outlet from first heat meter G 3/4 “ M USC2: water outlet from second heat meter G 3/4 “ M AE: hole for cables


Technical drawings - graphs - flue systems Models: Luna Sat R2H (A)

Connection tongues

Depth of the casing 150

Internal view of the case from B

L of the casing 800

CENTRALIZED SYSTEM CONNECTIONS IP1: heating inlet from the centralized system G 3/4’’ M UP1: heating outlet from the centralized system G 3/4’’ M IP2: cooling inlet from the centralized system G 3/4’’ M UP2: cooling outlet from the centralized system G 3/4’’ M HEATING-COOLING APARTMENT CONNECTIONS MR1: heating apartment flow G 3/4 “ M RR1: heating apartment return G 3/4 “ M MR2: cooling apartment flow G 3/4 “ M RR2: cooling apartment return G 3/4 “ M DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2: cold water inlet to second heat meter G 3/4 “ M USC1: water outlet from first heat meter G 3/4 “ M USC2: water outlet from second heat meter G 3/4 “ M

Screws seats

(B)

AE: hole for cables

Equiment of the case

External view of the casing from A

Insert the final part of the pipes inside the case Frontal view

Left side view

Models: Luna Sat RHG1 External view of the casing from A

USC2

AE

57,5 CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

73

108

USC1

70

IP

77

42

ESC2 AE

108

connection kit 144 39,5

RR

140

L of the casing 500

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 1’’ M apartment flow RR: heating G 1’’ M apartment return DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ or G 1’’ M ESC2 : cold water inlet to second heat meter G 3/4 “ or G 1’’ M USC1: water outlet from first heat meter G 3/4 “ or G 1’’ M USC2: water outlet from second heat meter G 3/4 “ or G 1’’ M

UP ESC1

AE: hole for cables

24

155,5

209,5

(B)

Height of the casing 850

420

62,5

connection kit 144

335

872

Screws seats

70

MR

42

327,5

24

162,5

77

Depth of the casing 150

73

(A)

162,5 Frontal view

Left side view

70

140

70

57,5

Internal view of the casing from B

Models: Luna Sat RPEH (B)

Depth of the casing 150

External view of the case from B

L of the casing 600

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

H cassetta 850

Screws seats

APARTMENT DHW CONNECTIONS UCS: DHW thermostatic outlet UFS: Cold water outlet EFS: Cold water inlet AE: hole for cables

Internal view of the casing from A

Insert the final part of the pipes inside the casing

Left side view

Frontal view

(A)

35


Model: Luna Sat RH1 without casing

Model: Luna Sat RPH without casing

L 400 min. 76,5

292

70

85

50

120

38

MR

RR US C1

235

H=846 min.

US C2

238

120

UP

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M

DHW CONSUMPTION METER CONNECTIONS ESC1 : cold water inlet to first heat meter G 3/4 “ M ESC2 : cold water inlet to second heat meter G 3/4 “ M USC1: water outlet from first heat meter G 3/4 “ M USC2: water outlet from second heat meter G 3/4 “ M

USC1: water outlet from first heat meter G 3/4 “ M USC2: water outlet from second heat meter G 3/4 “ M

ES ES C2 C1 IP

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

AE: hole for cables

AE: hole for cables

38 70 16,5

352

Model: Luna Sat RP-SP L of the box 150

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M

85 65

46

Upper view

411

APARTMENT DHW CONNECTIONS UFS: Cold water outlet G3/4’’ M EFS: Cold water inlet G3/4’’ M ESC: hot water inlet G3/4’’ M USC: hot water outlet G3/4’’ M

L of the casing 600

65 85

756

Screws Sedi per seats viti

APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

UP

123 65

Case height 850

Alette aggancio kit Connection

IP

USC ESC UFS EFS

V

AE: hole for cables V: safety valve discharge

AE

MR

RR

29 46

94 65 65 65 65 138 48 Frontal view

View from left side

60

View from below

Model: Luna Sat R60WH 450 425

=

= 2 holes for screws

ES : Cold water inlet G 1/2 “ M US: DHW outlet G 1/2 “ M IP : Primary inlet G3/4’’ M UP: Primary outlet G3/4’’M MR: heating G 3/4’’ M flow RR: heating G 3/4’’ M return VS: safety valve discharge

473

50

View from left side

65

MR

37,5 75 70

65 RR

33

450

Frontal view

48

910 821

910

Ø8

US

UP

65 IP

60 ES

VS

Model: Luna Sat RST

Upper view

CENTRALIZED SYSTEM CONNECTIONS IP : Primary inlet from centralized system G3/4’’ M UP: Primary outlet to centralized system G3/4’’M APARTMENT SIDE HEATING CONNECTIONS-MONOZONE MODELS MR: heating G 3/4’’ M apartment flow RR: heating G 3/4’’ M apartment return

Connection kit

L of the casing 600

AE: hole for cables

Connection kit

Frontal view

36

APARTMENT DHW CONNECTIONS UCS: DHW thermostatic outlet UFS: Cold water outlet EFS: Cold water inlet

View from left side

View from below


Technical drawings - graphs - flue systems

Accessories for high output condensing systems Flue Systems - Coaxial flue 38

- Dual flue - Flue accessories for cascade installation - Flexible ducting system

39 43 44

Hydraulic accessories 44 Thermoregulation accessories 48

Accessories available as option for Luna SAT

51

37


Flue pipe accessories Coaxial flue system: Luna Platinum - Luna Duo-Tec MP 50-70 kW Description Code PP coaxial flue pipe with terminal Ø 80/125 L=1000 mm supplied with wind proof terminal and sealing collar

KHG 714088910 •

PP coaxial flue pipe extension Ø 80/125 L=1000 mm

KHG 714088511 •

PP coaxial flue pipe extension Ø 80/125 L=500 mm

KHG 714088610 •

PP coaxial 90° bend - Ø 80/125

KHG 714088711 •

PP coaxial 45° bend - Ø 80/125

KHG 714088811 •

Coaxial flue system: Luna Platinum Description Code PP coaxial flue pipes with terminal Ø 60/100 L=750 mm supplied with windproof terminal and sealing collar

KHG 714059613 •

PP coaxial flue pipe extension Ø 60/100 L=1000 mm

KHG 714059516 •

PP coaxial flue pipe extension Ø 60/100 L=500 mm

KHG 714119810 •

PP coaxial 90° bend - Ø 60/100

KHG 714059717 •

PP coaxial 45° bend - Ø 60/100

KHG 714059817 •

Internal sealing collar Ø 100

KHG 714017710 •

PP vertical chimney terminal Ø 80/125(1)

KHG 714093510 •

PP reduction from Ø 80/125 to 60/100

KHG 714093910 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125

KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°

KHG 714093711 •

(1)

+KHG 714093910 •

Coaxial flue system: Luna Duo-Tec MP 50-70 kW Description Code

38

PP vertical chimney terminal Ø 80/125

KHG 714093510 •

Flat roof tile to be used with a vertical chimney terminal Ø 80/125

KHG 714093610 •

Pitched roof tile to be used with a vertical chimney terminal Ø 80/125; it is adjustable from 15° to 45°

KHG 714093711 •


Flue pipe accessories Coaxial flue system: Luna Duo-Tec MP 90-110 kW Description Code PP coaxial flue pipe extension Ø 110/160 L=1000 mm

KUG 714133810 •

PP coaxial flue pipe extension Ø 110/160 L=500 mm

KUG 714133710 •

PP coaxial 90° bend - Ø 110/160

KUG 714133610 •

PP coaxial 45° bend - Ø 110/160

KUG 714133510 •

PP vertical chimney terminal Ø 110/160

KUG 714133410 •

PP horizontal coaxial chimney Ø 110/160

KUG 714133310 •

Flat roof tile to be used with a vertical chimney terminal Ø 110/160

KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminal Ø 110/160; it is adjustable from 15° to 45°

KHG 714104910 •

Dual flue system: Luna Platinum Description Code Orientable dual flue system

710268902 •

PP dual flue system Ø 80 it includes: flue reduction, intake connection

KHG 714059113 •

PP vertical flue system B23 type installation

KHG 714111011 •

PP pipe extension Ø 80 L=1000 mm

KHG 714059411 •

PP pipe extension Ø 80 L=500 mm

KHG 714059910 •

PP pipe extension Ø 80 L=250 mm

710718301 •

PP 90° bend Ø 80

KHG 714059211 •

PP 45° bend Ø 80

KHG 714059311 •

Dual flue terminal Ø 80

KHG 714010410 •

PP reduction from Ø 80 to Ø 60

KHG 714075610 •

PP pipe extension Ø 60 L=1000 mm

KHG 714075310 •

PP pipe extension Ø 60 L=500 mm

KHG 714075210 •

PP 90° bend Ø 60

KHG 714075410 •

PP 45° bend Ø 60

KHG 714075510 •

39


Flue pipe accessories Dual flue system: Luna Platinum Description Code Dual flue terminal Ø 60

KHG 714037210 •

Pipe Ø 80 centring kit (pack of 5)

KHG 714037411 •

Clamp centring kit Ø 80

KHG 714106110 •

Pipe Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

External sealing collar Ø 80

KHG 714018411 •

Coaxial vertical chimney terminal Ø 80/125(1)

KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125

KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal

KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

KHG 714093711 •

(1)

+KHG 714093810 •

Dual flue system: Luna Duo-Tec MP 50-70 kW - floor standing boilers Power HT 45-65 kW Description Code

40

PP pipe extension Ø 80 L=1000 mm

KHG 714059411 •

PP pipe extension Ø 80 L=500 mm

KHG 714059910 •

PP pipe extension Ø 80 L=250 mm

710718301 •

PP 90° bend Ø 80

KHG 714059211 •

PP 45° bend Ø 80

KHG 714059311 •

Pipe Ø 80 centring kit (pack of 5)

KHG 714037411 •

Clamp centring kit Ø 80

KHG 714106110 •

Pipe Ø 80 supporting bracket (pack of 5)

KHG 714037310 •

Internal sealing collar Ø 80

KHG 714018510 •

External sealing collar Ø 80

KHG 714018411 •

Flue terminal Ø 80

LSD 790000150 •

Dual flue terminal Ø 80

KHG 714010410 •


Flue pipe accessories Dual flue system: Luna Duo-Tec MP 50-70 kW Description Code PP dual flue system Ø 80 it includes: flue reduction, intake connection

KHG 714089010 •

Coaxial vertical chimney terminal 80/125

KHG 714093510 •

Dual flue pipes adapter for coaxial chimney Ø 80/125

KHG 714093810 •

Flat roof tile Ø 125 to be used with a vertical chimney terminal

KHG 714093610 •

Pitched roof tile Ø 125 to be used with a vertical chimney terminal; it is adjustable from 15° to 45°

KHG 714093711 •

Dual flue system: Luna Duo-Tec MP 90-110 kW Description Code PP dual flue kit Ø 110/110

710631401 •

Dual flue system: Luna Duo-Tec MP 90-110 kW - floor standing boilers Power HT 85-150 kW Description Code PP pipe extension Ø 110 L=1000 mm

KUG 714133210 •

PP pipe extension Ø 110 L=500 mm

KUG 714133110 •

PP pipe extension Ø 110 L=250mm

710718501 •

PP 90° bend Ø 110

KUG 714133010 •

PP 45° bend Ø 110

KUG 714132910 •

PP reduction kit from Ø 110 to Ø 100(1)

KHW 714096910 •

PP vertical chimney terminal Ø 110

KUG 714132810 •

PP horizontal chimney terminal Ø 110

KUG 714132710 •

Flat roof tile to be used with a vertical chimney terminal Ø 110/160

KHG 714104810 •

Pitched roof tile to be used with a vertical chimney terminal 110/160; it is adjustable from 15° to 45°

KHG 714104910 •

(1)

only for floor standing boilers 85-150 kW

Dual flue system: floor standing boilers Power HT 45-150 kW Description Code Room air indipendent kit ( R.A.I.) Ø 80 for 45-65 kW boilers

LSB 710000100 •

Room air indipendent kit ( R.A.I.) Ø 100 for 85-100 kW boilers

LSB 710000110 •

Room air indipendent kit ( R.A.I.) Ø 100 for 120-150 kW boilers

LSB 710000120 • 41


Flue pipe accessories Dual flue system: floor standing boilers Power HT 230-320 kW Descrizione Codice

42

Extension pipe Ø 200 L=500 mm

LXO 000971911 •

Extension pipe Ø 200 L=1000 mm

LXO 000971928 •

Extension pipe Ø 200 L=2000 mm

LXO 000971935 •

87° bend Ø 200

LXO 000971942 •

45° bend Ø 200

LXO 000971959 •

Spacer Ø 200

LXO 000971973 •

Pitched roof tile Ø 200

LXO 000971997 •

SAS flue discharge 200-1B

LXO 000688673 •

SAS flue discharge 200-2B

LXO 000688680 •

Air grid Ø 200

LXO 000971980 •

87° bend Ø 200 with inspection

LXO 000971904 •

Up right duct with inspection hole

LXO 000971898 •

SAS vertical chimney terminal Ø 200

LXO 000989527 •

Passing roof Ø 200

LXO 000989497 •

Comburent air filter

LXO 000692656 •

Room air indipendent working (WAS 200)

LXO 000971881 •


Flue pipe accessories Flue accessories for cascade installation (for all boilers model, except for floor standing boilers Power HT 230-320 kW) Description Code PP flue pipe kit Ø 160 for two boilers

710715201 •

PP flue pipe kit Ø 200 for two boilers

710715601 •

PP flue pipe kit Ø160 for the third boiler

710716301 •

PP flue pipe kit Ø200 for the third boiler

710716401 •

PP 87° bend Ø160

KHW 714097810 •

PP 87° bend Ø200

KHW 714098210 •

PP pipe extension Ø160 L=1000 mm

KHW 714097710 •

PP pipe extension Ø200 L=1000 mm

KHW 714098110 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 50-70 kW - floor standing boilers Power HT 45-65 kW Description Code PP flue pipe kit for two boilers Ø 125

710716801 •

PP flue pipe kit Ø125 for the third boiler

710717701 •

PP shutter kit Ø 110/80 with condensing trap

710682001 •

PP 90° bend Ø 125

KHG 714094410 •

PP 45° bend Ø 125 (pack of 2)

KHG 714094510 •

PP pipe extension Ø 125 L=1000

KHG 714094610 •

Flue accessories for cascade installation: Luna Platinum - Luna Duo-tec MP 90-110 kW - floor standing boilers 85-150 kW Description Code PP shutter kit Ø 110/110 with condensing trap

710682101 •

Flue accessories for cascade installation: floor standing boilers Power HT 85-150 kW Description Code PP reduction kit from Ø 110 to Ø 100

KHW 714096910 •

Flue accessories for cascade installation: floor standing boilers Power HT 230-320 kW Description Code Manifold for 2 boilers in cascade 250 mm

LXO 000691444 •

43


Flue pipe accessories Flexible ducting system accessories: wall hung - floor standing boilers 45-65 kW Description Code PP flexible pipe Ø 80 L= 1,5 m

KHG 714105710 •

PP flexible pipe Ø 80 L= 20 m

KHG 714105810 •

PP tee joint Ø 80 with supporting bracket and condensate drainings

KHG 714105910 •

PP 90° bend Ø 80 with supporting bracket

KHG 714106010 •

Flexible centring kit Ø 80 (pack of 3)

KHG 714106210 •

Triple lips gaskets kit Ø 80 (pack of 5)

KHG 714111210 •

Hydraulic accessories (without safety device): Luna Platinum Description Code Manifold pipes for 2 Platinum boilers in cascade

KHG 714117111 •

Manifold pipes for the 3rd Platinum boiler in cascade

KHG 714117211 •

Neutralizer kit for wall hung boilers up to 100 kW

KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW

KHG 714135310 •

Heating systems taps and connection pipes with filter

710931401 •

Hydraulic accessories (with safety device): Luna Platinum Description

44

Codice

Manifold pipes for 2 Platinum boilers in cascade- right connection ( with safety device)

KHG 714117312 •

Manifold pipes for the 3rd Platinum boiler in cascade- right connection ( with safety device)

KHG 714117411 •

Manifold pipes for 2 Platinum boilers in cascade- left connection ( with safety device)

KHG 714117512 •

Manifold pipes for the 3rd Platinum boiler in cascade- left connection ( with safety device)

KHG 714117611 •

Neutralizer kit for wall hung boilers up to 100 kW

KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW

KHG 714135310 •

Heating systems taps and connection pipes with filter

710931401 •


Hydraulic accessories (without safety device): Luna Duo-tec MP single installation Single installation for Luna Duo-tec MP from 50 to 70 kW Code

Hydraulic kit with separator for a single boiler from 50 to 70 kW

71163301 •

Single installation for Luna Duo-tec MP from 90 to 110 kW Code

Gas delivery/return manifold kit for individual boiler 90-110 kW

710584601 •

Boiler-mainfold connection kit for 90 - 110 kW boilers

710678301 •

Expansion tank connection kit

710583802 •

Flanges and gaskets kit

710582702 •

Insulation kit for individual boiler flow/return manifolds 90 - 110 kW boilers

710587802 •

Hydraulic accessories (without safety device): Luna Duo-tec MP for boilers in cascade Boilers in cascade

from 50 to 70 kW

Code

n° of boilers 2

3

4

5

Gas delivery/return manifold kit for individual boiler 50 to 70 kW

710577501 •

-

1 pz

-

1 pz

Gas delivery/return manifold kit for two boilers 50 to 70 kW

710577701 •

1 pz

1 pz

2 pz

2 pz

Delivery-return-manifolds kit for individual boiler 50 to 70 kW without gas line

710886301 •

-

1 pz

-

1 pz

Delivery-return-manifolds kit for 2 boilers 50 to 70 kW without gas line

710886501 •

1 pz

1 pz

2 pz

2 pz

Expansion tank connection kit

710583802 •

2 pz

3 pz

4 pz

5 pz

Boiler-manifold connection kit for boilers 50 to 70 kW

710673801 •

2 pz

3 pz

4 pz

5 pz

Boiler-manifold kit for boilers 50 to 70 kW without gas line

710886101 •

2 pz

3 pz

4 pz

5 pz

Flanges and gaskets kit

710582702 •

1 pz

1 pz

1 pz

1 pz

Gas manifolds connection kit for cascade systems

710583201 •

-

1 pz

1 pz

2 pz

Insulation kit for individual boiler flow/return manifolds 50 to 70 kW

710587002 •

-

1 pz

-

1 pz

Insulation kit for two boilers flow/return manifolds 50 to 70 kW

710587502 •

1 pz

1 pz

2 pz

2 pz

Hydraulic accessories (without safety device): Luna Duo-tec MP for boilers in cascade Boilers in cascade

from 90 to 110 kW

Code

n° of boilers 2

3

4

5

Gas delivery/return manifold kit for individual boiler 90 to 110 kW

710584601 •

-

1 pz

-

1 pz

Gas delivery/return manifold kit for two boilers 90 to 110 kW

710584901 •

1 pz

1 pz

2 pz

2 pz

Delivery-return-manifolds kit for individual boiler 90-110 kW without gas line

710886401 •

-

1 pz

-

1 pz

Delivery-return-manifolds kit for 2 boilers 90-110 kW without gas line

710886601 •

1 pz

1 pz

2 pz

2 pz

Expansion tank connection kit

710583802 •

2 pz

3 pz

4 pz

5 pz

Boiler-manifold connection kit for boilers 90 to 110 kW

710678301 •

2 pz

3 pz

4 pz

5 pz

Boiler-manifold kit for boilers 90-110 kW without gas line

710886201 •

2 pz

3 pz

4 pz

5 pz

Flanges and gaskets kit

710582702 •

1 pz

1 pz

1 pz

1 pz

Gas manifolds connection kit for cascade systems

710583201 •

-

1 pz

1 pz

2 pz

Insulation kit for individual boiler flow/return manifolds 90 to 110 kW

710587802 •

-

1 pz

-

1 pz

Insulation kit for two boilers flow/return manifolds 90 to 110 kW

710588502 •

1 pz

1 pz

2 pz

2 pz

45


Hydraulic accessories (without safety device): Luna Duo-tec MP for boilers in cascade Hydraulic separators Code

Connection to hydraulic separator kit 8,5 m /h manifolds insulation kit for 8,5 m3/h hydr. separator Screws and gaskets for 8,5 m3/h hydr. separator Hydraulic separator HS 8,5 of 8,5 m3/h - 2“ threaded connectors

710686501 • 710687901 • LSD 790000440 • LSD 790000310 •

Connection to hydraulic separator kit 18 m3/h DN65 Manifolds insulation kit for 18 m3/h DN65 hydraulic separator Screws and gaskets for 18 m3/h DN65 hydr. separator Hydraulic separator 18 m3/h DN65

710687501 • 710688901 • LSD 790000430 • LSD 790000320 •

Connection to hydraulic separator kit 28 m3/h DN80 Manifolds insulation kit for 28 m3/h DN80 hydraulic separator Screws and gaskets for 28 m3/h DN80 hydr. separator Hydraulic separator 28 m3/h DN80

710687601 • 710689201 • LSD 790000420 • LSD 790000330 •

3

Hydraulic accessories (with safety device): Luna Duo-tec MP single installation Single installation for Luna Duo-tec MP from 50 to 70 kW Code

Hydraulic kit with separator for a single boiler from 50 to 70 kW

71163201 •

Single installation for Luna Duo-tec MP 90 - 110 kW Code

Gas delivery/return manifold kit for individual boiler 90-110 kW Boiler-mainfold connection kit for 90 - 110 kW boilers Expansion tank connection kit Flanges and gaskets kit Insulation kit for individual boiler flow/return manifolds 90 - 110 kW boilers Hydraulic safety devices kit (to be placed in the hydraulic separator connection kit)

710584601 • 710678301 • 710583802 • 710582702 • 710587802 • KHW 714098411 •

Hydraulic accessories (with safety device): Luna Duo-tec MP for boilers in cascade Boilers in cascade

from 50 to 70 kW

Gas delivery/return manifold kit for individual boiler 50 to 70 kW Gas delivery/return manifold kit for two boilers 50 to 70 kW Delivery-return-manifolds kit for individual boiler 50 to 70 kW without gas line Delivery-return-manifolds kit for 2 boilers 50 to 70 kW without gas line Expansion tank connection kit Boiler-manifold connection kit for boilers 50 to 70 kW Boiler-manifold kit for boilers 50 to 70 kW without gas line Flanges and gaskets kit Gas manifolds connection kit for cascade systems Insulation kit for individual boiler flow/return manifolds 50 to 70 kW Insulation kit for two boilers flow/return manifolds 50 to 70 kW Hydraulic safety devices kit (to be placed in the hydraulic separator connection kit)

Code

710577501 • 710577701 • 710886301 • 710886501 • 710583802 • 710673801 • 710886101 • 710582702 • 710583201 • 710587002 • 710587502 • KHW 714098411 •

n° of boilers 2

3

4

5

1 pz 1 pz 2 pz 2 pz 2 pz 1 pz 1 pz 1 pz

1 pz 1 pz 1 pz 1 pz 3 pz 3 pz 3 pz 1 pz 1 pz 1 pz 1 pz 1 pz

2 pz 2 pz 4 pz 4 pz 4 pz 1 pz 1 pz 2 pz 1 pz

1 pz 2 pz 1 pz 2 pz 5 pz 5 pz 5 pz 1 pz 2 pz 1 pz 2 pz 1 pz

Hydraulic accessories (with safety device): Luna Duo-tec MP for boilers in cascade Boilers in cascade

from 90 to 110 kW

Gas delivery/return manifold kit for individual boiler 90 to 110 kW Gas delivery/return manifold kit for two boilers 90 to 110 kW Delivery-return-manifolds kit for individual boiler 90-110 kW without gas line Delivery-return-manifolds kit for 2 boilers 90-110 kW without gas line Expansion tank connection kit Boiler-manifold connection kit for boilers 90 to 110 kW Boiler-manifold kit for boilers 90-110 kW without gas line Flanges and gaskets kit Gas manifolds connection kit for cascade systems Insulation kit for individual boiler flow/return manifolds 90 to 110 kW Insulation kit for two boilers flow/return manifolds 90 to 110 kW Hydraulic safety devices kit (to be placed in the hydraulic separator connection kit) 46

Code

710584601 • 710584901 • 710886401 • 710886601 • 710583802 • 710678301 • 710886201 • 710582702 • 710583201 • 710587802 • 710588502 • KHW 714098411 •

n° of boilers 2

3

4

5

1 pz 1 pz 2 pz 2 pz 2 pz 1 pz 1 pz 1 pz

1 pz 1 pz 1 pz 1 pz 3 pz 3 pz 3 pz 1 pz 1 pz 1 pz 1 pz 1 pz

2 pz 2 pz 4 pz 4 pz 4 pz 1 pz 1 pz 2 pz 1 pz

1 pz 2 pz 1 pz 2 pz 5 pz 5 pz 5 pz 1 pz 2 pz 1 pz 2 pz 1 pz


Hydraulic accessories (with safety device): Luna Duo-tec MP for boilers in cascade Hydraulic separators

Code

Connection to hydraulic separator kit 8,5 m /h (with safety devices connections)

710578401 •

manifolds insulation kit for 8,5 m3/h hydr. separator

710640601 •

3

Screws and gaskets for 8,5 m3/h hydr. separator

LSD 790000440 •

Hydraulic separator HS 8,5 of 8,5 m3/h - 2” threaded connectors

LSD 790000310 •

Connection to hydraulic separator kit 18 m3/h DN65 (with safety devices connections)

710579001 •

Manifolds insulation kit for 18 m3/h DN65 hydraulic separator

710642201 •

Screws and gaskets for 18 m3/h DN65 hydr. separator

LSD 790000430 •

Hydraulic separator 18 m /h DN65

LSD 790000320 •

3

Connection to hydraulic separator kit 28 m3/h DN80 (with safety devices connections)

710579301 •

Manifolds insulation kit for 28 m3/h DN80 hydraulic separator

710642801 •

Screws and gaskets for 28 m3/h DN80 hydr. separator

LSD 790000420 •

Hydraulic separator 28 m3/h DN80

LSD 790000330 •

Hydraulic accessories: Luna Duo-tec MP Description Code Hydraulic safety devices kit (available as optional)

KHW 714098411 •

Neutralizer kit for wall hung boilers up to 100 kW

KHG 714125610 •

Recharge for neutralizer kit for wall-hung boilers up to 100 kW

KHG 714135310 •

Hydraulic separator HS 56 of 56 m³/h - Ø 100 flanged connectors

LSD 790000340 •

Neutralizer kit for wall hung boilers up to 350 kW

KHG 714125710 •

Recharge for neutralizer kit for wall-hung boilers up to 350 kW

KHG 714135410 •

Hydraulic accessories: Luna Duo-tec MP 50-110 kW - floor standing boilers Power HT45-430 kW Description

Code

Brazed exchanger 50- 100kW

711261001 •

Brazed exchanger 50- 100kW

711261101 •

23P inspectable exchanger 200kW

711196001 •

27P inspectable exchanger 250kW

711196101 •

33P inspectable exchanger 300kW

711196201 •

37P inspectable exchanger 350kW

711196301 •

41P inspectable exchanger 400kW

711196401 •

Safety devices manifold kit

LSD 790000580 •

Manifold kit L=495

LSD 790000120 •

47


Hydraulic accessories: floor standing boilers Power HT 45-150 kW Description Code Manifold pipes single boiler/last boiler

KHW 714104210 •

Boiler-manifold pipe hydraulic connection

KHW 714104311 •

Manifold pipes boilers in cascade (45 cm between the boilers)

KHW 714099010 •

Manifold pipes boilers in cascade (2 cm between the boilers)

KHW 714103611 •

Hydraulic connection for 2nd pump (1)

KHW 714098612 •

Pump for hydraulic connection accessories

711187201 •

Hydraulic accessories for twin boilers in cascade Power HT 230-320 Description

(1)

Code

Connection kit 2 boilers in cascade KB1 – mod. HT 1.230

LXO000692632 •

Connection kit 2 boilers in cascade KB2– mod. HT 1.280-1.320

LXO000692649 •

the pump for hydraulic connection accessories is compulsory (711187201 •)

Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum - Luna Duo-tec MP floor standing boilers Power HT 45-150 kW Description

Code

Mixing valve motor

KHG 714078511 •

Mixing valve G1”

KHG 714078310 •

Mixing valve G1/2”

KHG 714078610 •

Mixing valve G3/4”

KHG 714078710 •

Flow/return sensor for controller for boilers in cascade and mixing system

KHG 714078810 •

Flow sensor for clip-in module

KHG 714078910 •

Hot water temperature sensor

KHG 714076810 •

Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description

Code

Outdoor sensor THINK

710487302 •

Outdoor sensor THINK (wireless)*

710302701 •

Interface kit for remote control THINK - 3 leds

710234003 •

Interface kit for remote control THINK - 5 leds wireless

710244103 •

Wireless aerial THINK

710234302 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244103 •) or the wireless aerial THINK (710234302 •)

48


Accessories for the thermoregulation, programming, setting and digital control - Luna Platinum Description

Code

Room thermostat THINK

710106106 •

Room thermostat (wireless) THINK*

710304405 •

Room thermostat with timer THINK

710298006 •

Room thermostat with timer THINK – wireless*

710297905 •

Programmable clip-in module THINK

710034504 •

Flow sensor for clip-in module THINK

KHG 714078910 •

Programmable external module THINK

710503705 •

Hot water temperature sensor

KHG 714076810 •

Interface kit for boilers in cascade THINK

710440803 •

Climate controller kit for mixing zones THINK

710519903 •

Sensor for solar controller

LNC 710000040 •

Accessories for the thermoregulation, programming, setting and digital control - Luna Duo-tec MP Description

Code

Outdoor sensor THINK

710487302 •

Outdoor sensor THINK (wireless)*

710302701 •

Wireless aerial THINK

710234302 •

Programmable clip-in module THINK

710034504 •

Programmable external module THINK

710503705 •

Hot water temperature sensor

KHG 714076810 •

Remote control THINK

710244203 •

Remote control THINK (wireless)

710244303 •

Climate controller kit for mixing zones THINK

710519903 •

Interface kit for boilers in cascade THINK

710440803 •

Sensor for solar controller

LNC 710000040 •

* wireless model to be ordered with the interface kit for remote control THINK - 5 leds (710244103 •) or the wireless aerial THINK (710234302 •)

49


Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 45-150 kW Description

Code

Outdoor sensor

710487302 •

Remote controller and climatic regulator

KHG 714072612 •

Boiler interface for mixing systems with two different temperatures zones

KHG 714077913 •

Bus interface for climatic regulators for boilers in cascade

KHG 714078013 •

Boiler control interface 0-10 V

KHG 714107612 •

Temperature regulator for mixing systems, it includes a temperature sensor

KHG 714078112 •

Cascade controller, it includes a temperature sensor

KHG 714078212 •

Room sensor: it can be installed only with climatic regulator for mixing system

KHG 714078410 •

Installation box for RVA controllers

KHG 714096610 •

Hot water temperature sensor for climatic regulator for boilers in cascade

KHG 714079010 •

Accessories for the thermoregulation, programming, setting and digital control - floor standing boilers 230-320 kW Description

Code

Outdoor sensor THINK

710487302 •

Interface kit for boilers in cascade

710440803 •

External tank sensor L=2 m

LSX 710000010 •

External tank sensor L=6 m

LSX 710000020 •

Accessory for managing mixing systems or solar panels

LSX 710000030 •

Climate controller kit for mixing zones THINK

710519903 •

LPG conversion kit: Luna Duo-tec MP Description

50

Code

LPG conversion kit for LUNA DUO-TEC MP 1.50

710718603 •

LPG conversion kit for LUNA DUO-TEC MP 1.60

710718702 •

LPG conversion kit for LUNA DUO-TEC MP 1.70

710718802 •

LPG conversion kit for LUNA DUO-TEC MP 1.90

710718902 •

LPG conversion kit for LUNA DUO-TEC MP 1.110

710719002 •


Accessories available as option Luna SAT Wireless data transmission Network node Network node with gateway Network node with gateway for transmission via GSM Remote reader device Software ACS 26 Connecting cable PC-network node for network note with gateway Wireless impulse adaptor AEW36.2

M-BUS data transmission Impulse adaptor AEW 310.2 M-BUS Connection cable heat meter M-BUS M-BUS central unit made of 250 loads M-BUS central unit made of 120 loads M-BUS central unit made of 60 loads M-BUS central unit made of 20 loads M-BUS central unit made of 60 loads for GSM transmission, e-mail Extension to 120 loads for GSM central unit, e-mail Extension to 250 loads for GSM central unit, e-mail Software for local reading of the GSM central unit, e-mail

Wireless control First flow meter - mod. R/1-RP/1-R2Z - RPE - RPB First flow meter - mod. RS-RSP-RS2Z Second flow meter - mod. RP/1 Second flow meter - mod. R/1-R2Z - RPE - RPB Flow meter - mod. RA-RA2Z First or second flow meter - mod. RH -RH1- R2H First or second flow meter - mod. RPH First or second flow meter RHG1 1’’ First or second flow meter RHG1 3/4’’ Flow meter - Luna Sat RC

M-BUS control First flow meter - mod. R/1-MB, RP/1-MB, R2Z-MB - RPE-MB, RPB - MB First flow meter - mod. RS-MB, RSP-MB, RS2Z-MB First or second flow meter - mod. RH-MB, RH1-MB, R2H-MB First or second flow meter - mod. RPH-MB Second flow meter - mod. RP/1-MB Second flow meter - mod. R/1-MB, R2Z-MB - RPE-MB, RPB-MB First or second flow meter RHG1-MB 1’’ First or second flow meter RHG1-MB 3/4’’ M-BUS flow meter - Luna Sat RC-MB

Thermoregulation Outdoor sensor Room thermostat (RT) Remote control and chronostat (mod. R2Z, RS, RSP, RS2Z, RA, RA2Z, RPE, RPEH - wireless and M-BUS) Digital chronostat (mod. R/1, RP1)

Code

KSV 714102711 • KSV 714103011 • KSV 714102811 • KSV 714102911 • KSV 714108611 • KSV 714116110 • KSV 714117710 • Code

KSV 714116210 • KSV 714116310 • KSV 714136910 • KSV 714137010 • KSV 714137110 • KSV 714137210 • KSV714146510 • KSV714146610 • KSV714146710 • KSV714146810 •

Code

KSV 714102511 • KSV 714102611 • KSV 714106312 • KSV 714110111 • KSV 714110011 • KSV 714114511 • KSV 714114611 • KSV 714124910 • KSV 714125111 • KSV 714131310 •

Code

KSV 714116410 • KSV 714116510 • KSV 714116610 • KSV 714116710 • KSV 714118210 • KSV 714118310 • KSV 714125010 • KSV 714125210 • KSV 714134310 •

Code

710487302 • KHG 714062810 • KSV 714109511 • KHG 714086711 •

51


Accessories available as option Luna SAT Other accessories

Heat meter UH50 G1 ¼’’ Heat meter UH50 G2’’ Heat meter UH50 G1’’ Heat meter UH50 DN 50 Heat meter UH50 DN 65 Heat meter UH50 DN 80 Wireless interface UH50 for ultrasonic heat-meter Well for NTC sensor (½” and ¾”) for UH50 Well for NTC sensor G1/2’’ for UH50 models DN50-DN60-DN80 (output up to 6 m3/h) Additional well for NTC sensor G 1/2” for UHG50 models G2” DN50-DN65-DN80 (output up to 10 m3/h) M-BUS interface UH50 for ultrasonic heat-meter Complete template for Luna Sat RH1 By-pass for Luna Sat RC By-pass ( inversione) for Luna Sat RC Heating hydraulic proof for Luna Sat RC Sanitary hydraulic proof for Luna Sat RC 2L Sanitary expansion vessel for Luna Sat R60WH 4L Sanitary expansion vessel (Luna Sat B60) GSM modem for DIN frame

Equipment (for all wireless/M-BUS models) (to be ordered for RH model) Hydraulic equipment for Luna Sat heating only models R/1, RP/1, RH, RH1, RPH, RPB, RPE, R2H (x2), RPEH Hydraulic equipment for Luna Sat heating and DHW production model RS, RSP Hydraulic equipment for Luna Sat models R2Z, RA, RA2Z Hydraulic equipment for Luna Sat heating / DHW production model RS2Z Hydraulic equipment for 2 flow meters for Luna Sat R/1, RP/1, RPB, RPE models Hydraulic equipment for 2 flow meters for Luna Sat RH, RPH, R2H. RPEH models

Mounting accessories (all casings has built-in taps except mod. RH and RHG1) Single zone casing - for R/1, RP/1, RPB, RPE, RSP, RA 2 zones casing - for R2Z, RS2Z, RA2Z Casing for RH 650x650 mm (without taps; cod. KSV 714120911 • to be ordered) Casing for R2H Casing for RHG1 (without taps) Casing for RPH - RPEH Casing for RC Casing for RST Casing for RP-SP

Cylinder Luna SAT B60 cylinder

Accessories for Luna Sat Rack (3 modules) 3 Luna Sat RC – Rack casing Flow/return collectors 3 Luna Sat RC- Rack DHW collector kit 3 Luna Sat RC- Rack DCW collector kit 3 Luna Sat RC- Rack Collector kit for the 3rd flow meter 3 Luna Sat RC- Rack

Accessories for Luna Sat Rack (4 modules) 4 Luna Sat RC – Rack case Flow/return collectors 4 Luna Sat RC- Rack DHW collector kit 4 Luna Sat RC- Rack DCW collector kit 4 Luna Sat RC- Rack Collector kit for the 3rd flow meter 3 Luna Sat RC- Rack 52

Code

KSV 714117810 • KSV 714117910 • KSV 714144810 • KSV 714144910 • KSV 714145010 • KSV 714145110 • KSV 714121710 • KSV 714127310 • KSV 714146910 • KSV 714127410 • KSV 714121810 • KSV 714122310 • KSV 714136310 • KSV 714139610 • KSV 714136410 • KSV 714136510 • KSV 714110410 • KSV 714110410 • KSV 714140810 • Code

KSV 714120911 • KSV 714121011 • KSV 714121110 • KSV 714121210 • KSV 714121310 • KSV 714121410 • Code

KSV 714145310 • KSV 714145410 • KSV 714117011 • KSV 714145510 • KSV 714124010 • KSV 714145610 • KSV 714131011 • KSV 714141210 • KSV 714142010 • Code

KSV 71410841 Code

KSV 714142311 • KSV 714142610 • KSV 714142810 • KSV 714142910 • KSV 714143010 • Code

KSV 714142411 • KSV 714142710 • KSV 714143110 • KSV 714143210 • KSV 714143310 •


Products technical data

High output condensing gas boilers

54

53


54 92/42/EEC

17,4

24,7

33

46,3

56,6

66,9

87,4

104,9

34,8

46,4

46,4

56,7

67

87,2

105

46,4

67

87,2

102,7

115

123,2

154

215

260

300

LUNA PLATINUM 1.18

LUNA PLATINUM 1.24

LUNA PLATINUM 1.32

LUNA DUO-TEC MP 1.50

LUNA DUO-TEC MP 1.60

LUNA DUO-TEC MP 1.70

LUNA DUO-TEC MP 1.90

LUNA DUO-TEC MP 1.110

LUNA HT 1.350

LUNA HT 1.450

LUNA HT 1.450 P

LUNA HT 1.550

LUNA HT 1.650

LUNA HT 1.850

LUNA HT 1.1000

POWER HT 1.450

POWER HT 1.650

POWER HT 1.850

POWER HT 1.1000

POWER HT 1.1150

POWER HT 1.1200

POWER HT 1.1500

POWER HT 1.230

POWER HT 1.280

POWER HT 1.320

DATA REFERRED TO POWER HT-A: SOON AVAILABLE

12,4

LUNA PLATINUM 1.12

48

42

35

41,5

40

40

36,8

33,1

13,8

12,2

29,8

26,4

20

16

15

15

15

11,7

9,7

7,4

6,3

5,1

3,3

2,5

2,1

2,1

294

254,5

210,1

150

120

115

100

85

65

45

102

85

65

55

45

45

33,9

102

85

65

55

45

32

24

16,9

12

45,9

40,2

33,5

40,4

39

39

35,8

32,2

13,4

11,8

29

25,7

19,3

15,5

14,5

14,5

14,5

11,4

9,4

7,2

6,1

5

3,2

2,4

2

2

97,4

97,4

97,3

97,4

97,4

97,4

97,4

97,5

97,3

97,3

97,4

97,5

97,3

97,4

97,3

97,3

97,3

97,2

97,3

97,2

97,2

97,4

97,6

97,6

97,6

97,7

105,7

105,6

105,4

107,2

107,5

107,5

107,4

107,3

107,6

107,6

107,4

107,3

107,6

107,5

107,6

107,6

107,6

107,4

107,3

107,6

107,6

107,6

107,6

107,6

108

108

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

HHHH

98,0

98,0

97,9

98,0

98,0

98,0

98,0

98,1

97,9

97,9

98,0

98,1

97,9

98,0

97,9

97,9

97,9

97,8

97,9

97,8

97,8

98,0

98,1

98,1

98,1

98,2

1,7

1,7

1,7

2,0

2,0

2,0

2,0

1,9

2,1

2,1

2,0

1,9

2,1

2,0

2,1

2,1

2,1

2,2

2,1

2,2

2,2

2,0

1,9

1,9

1,9

1,8

2,6

2,5

2,5

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,6

0,5

0,5

0,5

0,5

0,0

0,0

0,0

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

0,1

61

61

61

75

77

72

80

78

75

75

74

75

75

78

74

74

72

74

75

76

96

92

80

80

75

75

9,3

9,3

9,3

8,7

8,7

8,7

8,7

8,7

8,9

8,7

8,7

8,7

8,7

8,7

8,7

8,7

8,7

9,2

9,0

9,0

9,0

9,0

9,0

9,0

9,0

9,0

4,3

4,3

4,3

5,4

5,4

5,4

5,4

5,4

5,0

5,4

5,4

5,4

5,4

5,4

5,4

5,4

5,4

4,5

4,8

4,8

4,8

4,8

4,8

4,8

4,8

4,8

26

26

26

34

34

34

34

34

31

34

34

34

34

34

34

34

34

27

30

30

30

30

30

30

30

30

0,136

0,118

0,097

0,073

0,058

0,054

0,049

0,041

0,031

0,022

0,050

0,041

0,032

0,027

0,022

0,022

0,016

0,047

0,040

0,031

0,026

0,021

0,015

0,011

0,008

0,006

57

57

57

58

58

55

57

56

55

55

55

55

55

55

55

55

55

55

55

55

59

58

55

55

55

55

9,3

9,3

9,3

8,4

8,4

8,4

8,6

8,6

8,4

8,4

8,4

8,4

8,4

8,4

8,4

8,4

8,4

9,0

8,5

8,5

9,0

8,5

9,0

9,0

9,0

9,0

4,3

4,3

4,3

5,9

5,9

5,9

5,6

5,6

5,9

5,9

5,9

5,9

5,9

5,9

5,9

5,9

5,9

4,8

5,7

5,7

4,8

5,7

4,8

4,8

4,8

4,8

exceeding flue flue CO2 O2 air mass temp. and flow/rate max % kg/s °C % %

26

26

26

39

39

39

36

36

39

39

39

39

39

39

39

39

39

30

38

38

30

38

30

30

30

30

0,021

0,019

0,016

0,020

0,019

0,019

0,018

0,016

0,007

0,006

0,015

0,013

0,010

0,008

0,007

0,007

0,007

0,005

0,005

0,004

0,003

0,002

0,002

0,001

0,001

0,001

410

350

330

235

135

128

160

100

110

900

200

150

125

80

175

75

45

320

275

210

210

190

130

120

110

95

-

-

-

-

-

-

-

-

-

-

-

-

-

-

100

-

-

170

165

125

120

115

75

75

75

75

exceeding flue nominal nominal air mass boiler pump and flow/rate % kg/s W W

0085CL0072

0085CL0072

0085CL0072

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BQ0055

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085BP0256

0085CM0128

0085CM0128

0085CM0128

0085CM0128

0085CM0128

0085CM0140

0085CM0140

0085CM0140

0085CM0140

Nr.

Certificate EEC

Power consumption

burner

not working Maximum output Minimum Output

MAX. MIN. MAX. MIN. average 30% stars combustion chimney radiating chimney flue CO2 O2 temp. number efficiency heat heat heat temp. Pn 70°C 92/42/EEC losses losses losses max kW kW kW kW % % % % % % °C % %

Efficiency (Hi) Maximum Output

Heat input Heat output

PRODUCT

Products technical data – High output condensing boilers


55


Quality Environment Safety

Quality Environment Safety are Baxi strategic aims and the awarded certifications ensure compliance with the specific regulations

36061 BASSANO DEL GRAPPA (VI) - ITALY Via Trozzetti, 20 marketing@baxi.it www.baxi.it The Company assumes no responsibility for any possible contents mistakes, and reserves the right to make changes in products, due to technical or commercial demands, at any time without notice. Baxi S.p.A. 02-13 (E)


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.