COD Analyer new

Page 1

An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products

Model Des 2309


Put a sample of 2.00 ml in a vial, heat it for 15 minutes, select the program and finally read the results displayed after the COD analysis is complete.

Y PVT.

OCRAC

TECHN

TECHN OCRAC Y PVT.

LTD.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

LTD.


Chemical Oxygen Demand (COD) ANALYSIS SYSTEM

www.measuring-meters.com Chemical Oxygen Demand (COD) is the laboratory measurement of amount of oxygen used in chemical reactions that occur in water as a result of the addition of wastes to it. It measures the sum total of organic and inorganic pollution in waste water. COD is a measure of the relative oxygen-depletion effect of a waste contaminant in water. It is an essentially a laboratory test which acts as wastewater quality indicator and will have a significant adverse effect aquatic life in water.

Measurement of COD in • •

Wastewater Study of freshwater ponds and lakes

• •

Ecology Analysts and modelers working with determination of water quality.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


Chemical Oxygen Demand (COD) ANALYSIS SYSTEM

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


WORKING PRINCIPLE Our Fast Response COD analysis system works on the principle of oxidation of oxidisable material with a given amount of potassium chromate, the titration of excess chromate and the calculation of oxygen consumed.

®

ACY

PVT.

LTD.

TECHNOCR

®

TECHNOC RACY PVT.

LTD.

Put a sample of 2.00 ml in a vial, heat it for 15 minutes, select the program and finally read the results displayed after the COD analysis is complete.

FREQUENCY OF MEASUREMENT Ground water : Every 3 months Lakes : Every 2 months River : Every 2 weeks

Product Features: •

Transparent Protective Lid

Auto Shutdown at End of Completion of the Procedure

Technical Features: • • • • • • • •

Temperature for: Capacity Warm up Time Power Requirements Ambient Operating Temperature Temperature Stability Accuracy Timer

Range Adjustment

• : : : :

COD - 165°C • TP / TN - 105°C 24 vials of size 16 x 100 mm 20 minutes 220±22V, 50Hz, 300W 0 to 50 ?

: ±1? : ±1? : 1-1680 minutes(31 hours) with audible alarm And feature of being automatic : 105-165±1?, Shortcuts for 105? and 150?

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) 312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA Tel: 0091-11-23646703, 23643054 (M) +91-9313971681| Email: india@acmasindia.com

SALES OFFICE (HONG KONG) Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC). Tel: 0086-13929598046 | 0086-18922303099 Email: hk@acmasindia.com

SHOWROOM 141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA Tel: 0091-0-9312219738 (M) +91-9717741167 Email: info@acmasindia.com

SALES OFFICE (RUSSIA) Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA Tel: 0049-79592345 | Email: russia@acmasindia.com