Fluorescent Spectrometer

Page 1

Spectrophotometer

Fluorescent

An ISO 9001:2208 | ISO 14001:2008 | ISO 13485 WHO:GMP Products | GLP Compliant Products

Model Acm-1002-93-S


Fluorescent Spectrophotometer

The Acm-1002-93-S Fluorescent spectrophotometer is designed for high sensitivity and selectivity.

The measuring sensitivity of this instrument is 2-3 times higher than that of a UV-VIS s p e c t r o p h o t o m e t e r. Fluorescence

The

Acm-1002-93-S

spectrophotometer

provides

measurement of excitation & emission spectra, intensity, lifetime, and fluorescence polarization. The design is based on a manual Czerny-Turner manual monochromator and a photomultiplier detector.

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


Pharmaceutics

&

pharmacology

--

pharmaceutical quality control and metabolism research

Biochemistry--Quantitative minute substance measurement in biological samples

Food industry--Measurement of trace components in food

Pollutant analysis--Air pollution analysis, environmental hygiene detection, food pollutants analysis.

Organic & inorganic chemistry--Analysis of trace components which can not be measured with absorptive spectrophotometer

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

Application


Fluorescent Spectrophotometer •

Special light source with high brightness and long service life. (Longer service lifetime than high-pressure xenon lamp and high-pressure mercurylamp.)

Low noise and high sensitivity with a high-performance Hamamatsu photomultiplier

Instrumental S/N can reach to 1×10-9/ml(quinine slufate)

Good thermal stability

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


Fluorescent Spectrophotometer

Wavelength Range

Excitation 360~600nm (optical filter) Emission 360~650nm (Czerny-Turner diffraction grating)

Wavelength Accuracy

EM less Âą2nm

Sensitivity

1Ă—10-9/ml (quinine sulfate)

Linearity Error

less than 3.0%

Wavelength reproducibility

EM less 1nm

ACMAS TECHNOCRACY PVT. LTD. www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com


www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com

TECHNOCRACY PVT. LTD. SALES OFFICE (INDIA) 312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA Tel: 0091-11-23646703, 23643054 (M) +91-9313971681| Email: india@acmasindia.com

SALES OFFICE (HONG KONG) Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC). Tel: 0086-13929598046 | 0086-18922303099 Email: hk@acmasindia.com

SHOWROOM 141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA Tel: 0091-0-9312219738 (M) +91-9717741167 Email: info@acmasindia.com

SALES OFFICE (RUSSIA) Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA Tel: 0049-79592345 | Email: russia@acmasindia.com