RAYSET
速
Apparatus
Assembly instructions
Ray Set速
Ray Set Apparatus: Components T Metal Base (Fig. 01)
Fig. 01
Square Stone Base (Fig. 02)
Fig. 02
“Delta” Measurement Gauge Device (Fig. 03)
Fig. 03
Pag. 01
Lift Up & Down Unit (Fig. 04)
Fig. 04
RTT Base (Fig. 05)
Fig. 05
Tip & Burs Holder Tool (Fig. 06)
Fig. 06
Pag. 02
Laser Tool & Batteries (Fig. 07)
Fig. 07
Center Bit & Implant Analog Holder (Fig. 08)
Fig. 08
Mounting Exe Key (Fig. 09)
Fig. 09
Pag. 03
Ray Set Apparatus: The assembly procedure Lower Centering Plate + Long Screws (Fig. 10)
Fig. 10
Positionig On The Lower Face Of The Square Stone Base (Fig. 11)
Fig. 11
Upper Centering Plate Positioning (Fig. 12)
Fig. 12
Pag. 04
Assemble By Fixing The Long Screws (Fig. 13)
Fig. 13
Superimpose The “Delta Device” On The Square Stone Base (Fig. 14)
Fig. 14
Superimpose The Lift Unit On The “Delta” Device (Fig. 15)
Fig. 15
Pag. 05
Fix The Lift Unit On The “Delta” Device By mounting Exe Key And The Two Shortest Screws (Fig. 16)
Fig. 16
The Assembled Ray Set® Apparatus (Fig. 17)
Fig. 17
Pag. 06
Ray Set Apparatus: The RTT Base and RaySet Kinematics
Pag. 07
Ray Set Apparatus: The RTT Base resetting procedure The Lateral Right Or Lateral Left Screw Manages The Yellow RTT Tipping Correction Movements Required (Fig. 18)
Fig. 18a Use The opposite Screw To Set The Best working Friction (Fig. 18a)
Fig. 18
The Anterior Screw Manages The Red RTT Movement (Fig. 19)
Fig. 19a Use The opposite Screw To Set The Best working Friction (Fig. 19a)
Fig. 19
Setting To 00° (Degrees) The Horizontal Goniometric Black Scale And Fix It By The Below Screw (Fig. 20)
Fig. 20a The Below Screw (Fig. 20a)
Fig. 20
Pag. 08
Setting 00° Against 00° The Yellow Goniometric Scale By The Mobile Index On The Internal 00° And Then On The 00° External One. (Fig. 21)
Fig. 21
Setting 00° Against 00° The Red Goniometric Scale By The Mobile Index On The Internal 00° And Then On The 00° External One. (Fig. 22)
Fig. 22
The RTT Base Resetting Is Finalized To Have The RTT Model Base At Right Angle With tip (Fig. 23)
Fig. 23
Pag. 09
Ray Set Apparatus: Up and Down Lift Use Setting The Control Vertical Gauge On 0 mm. By Using The Ring Nut (Fig. 24)
Fig. 24
Up And Down Movement (Fig. 25)
Fig. 25
Set And Fix The Magnetic Sliding Jig To Record The Height Model Gingival Point (Center Bit On The Model Gengival Point) (Fig. 26)
Fig. 26
Pag. 10
Ray Set Apparatus: The “Delta” Linear Gauge Kinematics Use The Rocking Posterior Lever (A) + Small Distal Screw (B) To Have The Pantographic Movement (Fig. 27)
A B
Fig. 27
Fix The Median Small Screw (A) And The Distal Small Screw (B) To Meausure The Linear Correction (Fig. 28) Use The Anterior Small “Gold”Screw (C) To Produce The Linear Correction Required (Fig. 28)
C A B
Fig. 28
Switch On And Reset Measurement Display (Fig. 29)
Fig. 29
Pag. 11
Select The Angular Movement Direction On The Horizontal Black&Red Goniometric Scale (Fig. 30)
Fig. 30
Center Bit On The Gingival Model Point (Fig. 31)
Fig. 31
Angular Correction To Set The New CBR Point (Fig. 32)
CBR
δ MGP
Fig. 32
Pag. 12
Š Biaggini Medical Devices 2008 - Ph. Cesare Mulas
Biaggini Medical Devices srl Viale San Bartolomeo, 95/105 19126 La Spezia (Italy) Telefono: (+39) 0187-509575 / 509772 Fax (+39) 0187-599076 web: www.biaggini.it e-mail: biaggini@biaggini.it