Westex - Style Nomex Synergy Freedom.

Page 1

INHERENTLY FR FABRICS

Synergy

INDUSTRIAL Flash fire Electric arc

COMPLIANCE NFPA 2112 NFPA 70E HRC 1 ASTM F 1506 NFPA 1975 CAN-CGSB 155.20 CAN-CGSB 155.22

®

Made in America by Springfield LLC

You’ll lose FR protection only if you lose the garment. Garments made with Synergy® fabric, powered by Nomex® IIIA fiber, provide inherent heat and flame resistance, along with excellent durability — wash after wash. In addition, Synergy will not melt, drip or burn. In chemically treated fabrics, such as cotton/nylon blends, FR protection can wear away over time and may lose flame resistant properties completely when laundered with bleach or other chemicals. Unlike chemically treated fabrics, protection provided by Synergy is built into the fabric, so the inherent thermal protection properties can never be washed out or worn away. Fact is, the inherent FR protection lasts longer than the garment. Synergy fabric protects workers in the petroleum, petrochemical, electric & gas utility industries, as well as the fire service and racing markets, from the heat and flame of flash fire. It meets the NFPA 2112 and NFPA 70E HRC 1 standards and lasts longer than FR treated fabrics, making it a great value.

Synergy is available with AirWeave Technology, which increases the comfort of traditional Nomex by keeping the wearer cooler and more comfortable.

For shirts, pants and coveralls.

Choose from four proprietary finishes: • Freedom – a soil-release wickable finish, keeps the fabric looking like new after numerous washings and rugged use. • Comfort Freedom – a soil-release wickable finish with a softer hand that adds comfort. • SAABA – a premium, soil-release finish that gives the wearer prewashed softness without the loss of protective performance. Superior breathability and optimized moisture management to keep you cooler, drier and more comfortable. • Hydropel – a durable water repellent finish to keep you drier.


Synergy

You’ll lose FR protection only if you lose the garment.

®

Fiber Blend: 93% NOMEX® 5% KEVLAR ® 2% P140

Typical Physical Properties

UL 1503

UL 2531

UL 4531

UL 3531

UL 6531

UL 7531

UL 8531/UL 8532

Width (inches) Cuttable 60-61 60-61 60-61 60-61 60-61 60-61 60-61 66-67 66-67 Weight (± 5%)

(oz/yd²)

3.3

(g/m ) 112 2

Weave

Plain

Standard Colors (all weights)

3.3

4.5

5.0

6.0

6.5

7.5

112

153

170

203

220

254

PJ Check

Midnight Navy Natural

Navy Khaki

Plain

Plain

Plain

2x1 Twill

Square Weave

Royal Springs Blue Spruce #60023Q Spruce #60177Q Safety Yellow Orange Red Grey Black

Flame Resistance (warp x fill) ASTM D 6413 After Flame (seconds) Char Length (inches) Melt or Drip (Initial & after 100 laundry cycles)

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

2.0 x 2.0 max 4.0 x 4.0 max None

Thermal Protective Performance NFPA 2112 (cal/cm2, contact) (cal/cm2, spaced)

n/a n/a

n/a n/a

3.0 min 6.0 min

3.0 min 6.0 min

3.0 min 6.0 min

3.0 min 6.0 min

3.0 min 6.0 min

Level 1

Level 1

Passes NFPA 2112 Requirements

Flash Fire Exposure (Manikin Test)

ASTM F 1930 (% Body Burn [2.0 cal/cm2 /sec] @ 3 sec)

Arc Thermal Performance APTV ASTM F 1959 After 3 washes, 120ºF (cal/cm2)

n/a

n/a

Heat Resistance (500°F, 5 min) NFPA 2112 (Initial & after 100 laundry cycles) Thermal Shrinkage Resistance

Level 1

Level 1

Level 1

No Burning, Melting, Separation or Ignition

NFPA 2112

(%, warp x fill [500°F, 5 min]) 10 x 10 max 10 x 10 max 10 x 10 max 10 x 10 max 10 x 10 max 10 x 10 max (Initial & after 100 laundry cycles) Radiant Protective Performance(RPP)

NFPA 1977

10 x 10 max

n/a

n/a

n/a

n/a

7 min

7 min

7 min

Tensile Strength (lbs, warp x fill)

ASTM D 1682

105 x 99

115 x 100

172 x 126

184 x 150

225 x 173

252 x 178

290 x 225

Tear Strength (lbs, warp x fill)

ASTM D 1424

7.8 x 7.2

6.5 x 6.6

10.4 x 8.0

8.7 x 7.0

12.0 x 8.8

11.0 x 7.4

14.9 x 12.0

5.0 x 5.0 max

5.0 x 5.0 max

3.0 x 3.0 max

3.0 x 3.0 max

3.0 x 3.0 max

3.0 x 3.0 max

3.0 x 3.0 max

Dimensional Stability (%, warp x fill) AATCC 135 After 5 washes 120°F

Meets or Exceeds Specs for NFPA 1975* NFPA 1975*

NFPA 1975 NFPA 1975 NFPA 1975 NFPA 1975 NFPA 2112 NFPA 2112 NFPA 1977 NFPA 1977 CAN-CGSB 155.20 ASTM F 1506 NFPA 2112 NFPA 2112 ASTM F 1506 NFPA 70E ASTM F 1506 ASTM F 1506 * 3.3 oz Plain Weave and 3.3 oz PJ meet the requirements NFPA 70E NFPA 70E NFPA 70E of NFPA 1975 & NFPA 1977 as pocketing components only CAN-CGSB 155.20 CAN-CGSB 155.22 CSA Z-96 Orange #20103Q Only

NFPA 1977 *

NFPA 1977 *

Copyright © 2015 Springfield. NOMEX® and KEVLAR® are registered trademarks of E.I. duPont de Nemours and Company or its affiliates. All rights reserved.

3/2015 v1

Performance terms and corresponding testing results refer to typical performance in specified tests and should not be construed to imply behavior of FR performance under other conditions, or to substitute for testing that you may need to conduct. Textile resistance to flame is only one aspect of a product’s ability to meet or exceed a safety standard for clothing. It is the apparel manufacturer’s responsibility to determine the suitability of our product for a particular purpose. Springfield makes no warranties and assumes no liability in any connection with the use of this information.

NFPA 1971 NFPA 1975 NFPA 70E NFPA 1977 NFPA 2112 ASTM F 1506

FR Fabrics Made with American Ingenuity Executive Office-Sales & Marketing 100 Jericho Quadrangle, Suite 340 Jericho, New York 11753 (516) 861-6250 www.springfieldllc.com