2009 Maxilume Lutron Product Catalog

Page 1

Save energy and enhance comfort Efficient, dimmable compact fluorescent fixtures

www.LUTRON.com

Lutron

A


Lutron® dimming ballasts in every Elite and Maxilume lighting fixture now

Elite and Maxilume Lighting are proud to announce our newest partnership with Lutron. We now offer a new full line of recessed lighting fixtures equipped with Lutron dimming ballasts for all your project needs. Elite and Maxilume Lighting with Lutron are energized by a relentless drive to promote the highest standards in the lighting industry with the best lighting products for all types of applications. With Elite or Maxilume, you can get the best-performing dimmable fixtures for a wide variety of applications including retail, hospitality, corporate, institutional and residential projects.

Lutron invented the world’s first electronic dimming ballast over 30 years ago. From that point forward, Lutron continues to lead the industry with innovative and energy-saving fluorescent dimming options. Lutron offers an extensive selection of ballasts and controls, providing complete fluorescent dimming systems. B

Lutron

www.LUTRON.com

Hi-lume®, world's only 100% to 1% dimming ballasts for T4 compact fluorescent lamps


Dimming compact fluorescent fixtures Dimming architectural compact fluorescent fixtures create an enticing ambiance and enhance comfort. Meanwhile, lower light levels use less current so you save energy as the lamps are dimmed. Our fixtures with Lutron dimming ballasts provide you with maximized performance of light output, minimized energy usage, prolonged lamp life and the compatibility with any Lutron dimming system.

The benefits of Lutron dimming ballasts Designed to meet the most demanding lighting requirements of any application, Lutron dimming ballasts are the best and the most efficient available. They provide continuous, flickfree dimming, and are 100% performance tested. They are manufactured with the highest level of quality, using longlasting components that are carefully selected.

Best-in-class service For the first time, we are proud to offer same-day shipping on the complete line of our architectural and residential downlights with Lutron dimming ballasts to meet your needs. We offer unparalleled customer service from both companies—having all your lighting needs and technical problems taken care of is just a phone call away.

www.LUTRON.com

Lutron

1


Lutron

®

| table of contents

Why dim fluorescent? Measured light vs. perceived light Dimming applications Lutron quality Hi-lume® 1 % dimming ballasts Compact SE™ 5 % 3-wire dimming ballasts Tu-Wire® 5 % 2-wire dimming ballasts Select your dimming ballasts Ballast case dimensions Fluorescent dimming controls Select your fluorescent dimming controls

3 4 5 6 8 10 12 14 17 18 20

How to use this selection guide: The Fluorescent Dimming Systems Selection Guide helps you: • Determine the dimming range required for your application • Choose the appropriate Lutron dimming ballast • Choose the appropriate Lutron fluorescent control

|

|

MAXILUME Elite Lighting table of contents Architectural Downlighting HH4SQPL 4" Square CFL Trims HV4PL HV4PLIC-AT HVR4PL HVJ4PL 4" Vertical CFL Trims HV6PL HVR6PL HVJ6PL BHVR6PL 6" Vertical CFL Trims HV8PL HVR8PL HVJ8PL 8" Vertical CFL Trims HV10PL 10" Vertical CFL Trims HS6PL 6" Horizontal Shallow Trims

2

Lutron

28 29 30 31 32 33 34 36 37 38 39 40 44 45 46 47 52 53 54 55

HH6PL HH6PLIC-AT BHHR6PL HHR6PL HHJ6PL 6" Horizontal CFL Trims HS8PL 8" Horizontal Shallow Trims HH8PL HHR8PL HHJ8PL 8" Horizontal CFL Trims HH10PL 10" Horizontal CFL Trims HW6PL HW8PL Sloped Ceiling Adapter

www.LUTRON.com

Residential Downlighting 58 59 60 61 62 63 68 69 72 73 74 75 80 81 82 83 84

HV4PLIC-AT 4" Vertical CFL Trims B4PL-E B4PLR-E 4" CFL Trims B5PLIC-E B5PLRIC-E B5PL-E B5PLR-E 5" CFL Trims B6PLIC-E B6PLRIC-E B6PL-E B6PLR-E B6PLIC-26 OR 32-E 6" CFL Trims B36PLIC-E B36PLRIC-E 6" Slope CFL Trims

88 89 92 93 94 96 97 98 99 101 102 103 104 105 106 107 112 113 114

EMERGENCY BATTERY PACK 116-117


Lutron

| why dim fluorescent?

The benefits of dimming Create the perfect ambiance Dimming creates a rich visual experience and adds flexibility to any room, providing the right lighting environment for a variety of activities.

Give employees greater personal control Allowing employees to set preferred light levels for specific tasks results in greater employee comfort and improved performance.

Save electricity and maintain lamp life Dimming saves electricity and reduces the demand on HVAC systems. Dimming fluorescent lighting instead of repeated switching helps to maintain expected long lamp life.

Combine lighting control strategies to enhance building performance Using occupancy/vacancy sensors, daylight sensors and automated time-based controls with fluorescent dimming helps manage the lighting in an entire building and further reduce electric demand.

Dimming fluorescent lights saves energy Fluorescent lighting uses much less power than incandescent lighting. In a typical installation, a 32 watt compact fluorescent lamp provides approximately the same light output as a 100 watt incandescent lamp.

As both sources are dimmed, fluorescent lamps continue to be a more energy efficient light source.

100 W

Power consumed by incandescent source

Power

80 Over 60 watts of power is saved per fixture by using fluorescent lamps

60 40

Power consumed by fluorescent source

20 0

0

20

40

60

80

100 %

Measured Light

www.LUTRON.com

Lutron

3


Lutron

| measured light vs. perceived light

The human eye responds to low light levels by enlarging the pupil, allowing more light to enter the eye. This response results in a difference between measured and perceived light levels.

A lamp that is dimmed to 10 % of its maximum measured light output is perceived as being dimmed to only 32 %. Likewise, a lamp dimmed to 1 % is perceived to be at 10 %.

1 % Architectural dimming 5 % High performance dimming 10 % Lighting management dimming 100 % 90 80 70 60

Measured Light

50 40 30 20 10 5 1 0

10

22

32

40

50

60

70

80

90 100 %

Perceived Light

Measured Light (%) Formula: Perceived Light (%) = 100 x 100 Source:

4

IESNA Lighting Handbook, 9th Edition, (New York: IESNA, 2000), 27-4.

Lutron

www.LUTRON.com


Lutron

®

| dimming applications 1% Architectural dimming

5% High performance dimming

Small meeting room

Conference room/Boardroom

Lecture hall

Patient room/Examination and treatment room

• • •

House of worship

Lobby Hotel guest room Residential (See page 30 for appropriate ballast types.)

Theater

Convention area

Restaurants

Air traffic control center

Industrial control room

Graphic art workstation

CAD/CAM workstation

Retail

Presentation spaces

Critical task spaces

Design example

At full brightness, the measured light in a space is 60 foot-candles. At the lowest dimmed level, 10 % perceived light is desired.

1 % measured light (0.6 fcd) is perceived as 10 % (desired result)

5 % measured light (3 fcd) is perceived as 22 % (2x brighter than desired)

www.LUTRON.com

Lutron

5


Lutron

ÂŽ

| quality

Components in a Hi-lume 1 % dimming ballast for compact fluorescent lamps

Thermal Foldback Lutron patented Thermal Foldback technology is included in high-power ballasts, and actively monitors the ballast temperature. When necessary, power delivery to the lamps is automatically reduced, or “folded back�, to regulate ballast temperature, with minimal impact on light output. Thermal Foldback is designed to activate only if the ballast is operated in the environment that exceeds the ballast temperature rating.

6

Lutron

www.LUTRON.com

This technology prevents premature ballast failure due to overheating. In a properly designed application, Thermal Foldback will not engage. Refer to Fluorescent Dimming Systems Technical Guide P/N 366-606 for information about proper installation and the calibration point.


Superior components Lutron ballasts are manufactured to the highest level of quality, using carefully selected components. Maximum ballast lifetime is achieved by using only long-life components with significant performance history. In many cases, Lutron works with component suppliers to design custom parts in order to improve overall ballast quality.

Additionally, Lutron uses only metal ballast enclosures, allowing for optimal heat transfer to the lighting fixture.

Failure Rate

Product Reliability Curve

Customer receives Lutron ballast

˚

Running ballasts 10 C Cooler Useful life

Low failure rate

Lutron test and burn-in

100 % Test Lutron® tests the performance of every ballast prior to shipment. This important step eliminates ballasts that do not meet specifications. 100 % Burn-in Lutron “burns in” every ballast prior to shipment. Defects due to faulty components are screened out in this process, resulting in a dramatic reduction of early failures in the field.

DOUBLES useful life

Lutron dimming ballasts are burned in prior to shipment, ensuring lower failure rate in the field. Running ballasts 10 ºC cooler can also double their useful life.

Time

Extending ballast lifetime All electronic ballasts use components with a finite lifetime. A major factor for ballast lifetime is operating temperature. For every 10 ºC reduction in ballast case temperature, the ballast lifetime will be doubled. Lutron dimming ballasts are designed to maximize ballast lifetime by operating at a lower temperature, either through design or fixture choice.

www.LUTRON.com

Lutron

7


Lutron

®

| 1 % architectural dimming Hi-lume

®

Experience the benefits of true full-range 100 % to 1 % compact fluorescent dimming. Designed to meet the most demanding lighting requirements and featuring the world’s only 100 % to 1 % dimming ballasts for T4 compact fluorescent lamps, Hi-lume ballasts enable you to provide the ideal visual environment for any application. Integrating Hi-lume 1 % technology into your designs affords you full control over the lighting in any space. For the complete listing of Hi-lume ballasts, please see pages 14-15.

Dims T4 triple-tube compact lamps

Slim-profile design–just 1" high

Color-keyed push-in connectors

Available with or without mounting studs

8

Lutron

www.LUTRON.com


|

Hi-lume® 1 %

Performance

Specifications

Continuous, flicker-free dimming from 100 % to 1 %

Architectural dimming from 100 % to 1 % relative light output

3-wire line voltage control for consistent fixture-to-fixture dimming

Lamps turn on at any dimmed level without flashing to full brightness

Low harmonic distortion

No visible flicker

Total Harmonic Distortion (THD) less than 10 %

Power factor greater than .95

Ballast factor greater than .95

Frequency of operation greater than 42 kHz

Miswire protection

Inaudible in 27 dBA ambient environment

100 % performance tested

Inrush current limiting circuitry built-in (maximum of 7 amps for 120 V and 3 amps at 277 V)

Ultra-quiet operation

Designed in the USA

Internal fusing

5-year warranty (limited) with field service commissioning (3-year warranty standard)

Minimum lamp starting temperature 10 °C (50 °F)

Maximum ballast case temperature 75 °C (167 °F)

3-wire control For the full offering of Hi-lume dimming ballast controls by Lutron®, please see pages 20-21.

Hot 120 / 277 VAC 60 Hz Feed

Control

Hot Dimmed Hot Neutral

Dimming Ballast

Neutral

www.LUTRON.com

Lutron

9


Lutron

®

| 5 % high performance dimming Compact SE

TM

For designs requiring the energy savings and aesthetic appeal of dimmed compact fluorescent lamps, Compact SE dimming ballasts are your solution. The Compact SE product family includes ballasts for nearly every type of compact fluorescent lamp. Compact SE dimming ballasts deliver high performance 100 % to 5 % dimming, making them ideal for use in a variety of applications. In addition, Compact SE ballasts are compatible with the full line of 3-wire controls by Lutron. For the complete listing of Compact SE ballasts, please see pages 14-15.

Dims T4 quad- and triple-tube compact lamps

Slim-profile design–just 1" high

Color-keyed push-in connectors

Available with or without mounting studs

10

Lutron

www.LUTRON.com


Compact SE

TM

Performance

|5%

Specifications

Continuous, flicker-free dimming from 10 % to 5 %

3-wire line voltage control for consistent fixture-to-fixture dimming

Lamps turn on at any dimmed level without flashing to full brightness

Low harmonic distortion

High performance dimming from 100 % to 5 % relative light output

No visible flicker

Total Harmonic Distortion (THD) less than 10 %

Power factor greater than .95

Ballast factor greater than .95

Frequency of operation greater than 42 kHz

Miswire protection

Inaudible in 27 dBA ambient environment

100 % performance tested

Inrush current limiting circuitry built-in (maximum of 7 amps for 120 V and 3 amps at 277 V)

Ultra-quiet operation

Designed in the USA

Internal fusing

5-year warranty (limited) with field service commissioning (3-year warranty standard)

Minimum lamp starting temperature 10 °C (50 °F)

Maximum ballast case temperature 75 °C (167 °F)

3-wire control For the full offering of Compact SE dimming ballast controls by Lutron®, please see pages 20-21.

Hot 120 / 277 VAC 60 Hz Feed

Control

Hot Dimmed Hot Neutral

Dimming Ballast

Neutral

www.LUTRON.com

Lutron

11


Lutron

®

| 5 % high performance dimming Tu-Wire

®

Retrofit applications can benefit from the ease of installation offered by Lutron Tu-Wire dimming ballasts. Tu-Wire ballasts offer high performance 100 % to 5 % dimming for linear and compact fluorescent lamps. Tu-Wire ballasts require only two wires (hot and neutral) for power and control. Lutron offers a wide range of compatible 2-wire controls, making Tu-Wire a perfect choice for many applications. Additionally, one-lamp T4 models have been designed to meet FCC Part 18 consumer requirements. For the complete listing of Tu-Wire ballasts, please see page 16.

Dims T4 quad- and triple-tube compact lamps

Color-keyed push-in connectors

Available with or without mounting studs

12

Lutron

www.LUTRON.com


|

Tu-Wire® 5 %

Performance

Specifications

Continuous, flicker-free dimming from 100 % to 5 %

High performance dimming from 100 % to 5 % relative light output

No visible flicker

2-wire line voltage control for retrofit applications

Total Harmonic Distortion (THD) less than 20 %

Lamps turn on at any dimmed level without flashing to full brightness

Low harmonic distortion

Power factor greater than .95

Ballast factor greater than .85

Frequency of operation greater than 42 kHz

One-lamp T4 models meet FCC Part 18 consumer requirements for residential use (FCC ID: JPZB001)

Inaudible in 27 dBA ambient environment

Inrush current limiting circuitry built-in (maximum of 7 amps inrush current per ballast)

100 % performance tested

Internal fusing

Ultra-quiet operation

Minimum lamp starting temperature 10 °C (50 °F)

Designed in the USA

5-year warranty (limited) with field service commissioning (3-year warranty standard)

Maximum ballast case temperature 75 °C (167 °F)

2-wire control For the full offering of Tu-Wire dimming ballast controls by Lutron®, please see page 22. Control Hot 120 VAC 60 Hz Feed

Dimmed Hot

Neutral

Dimming Ballast

Neutral www.LUTRON.com

Lutron

13


Lutron

®

|

Lamp Type T4 4-Pin Quad-Tube

Hi-lume and Compact SE 120 volt 3-wire dimming ballasts ®

Lamp Lamps Watts per Case (Length) Ballast Type1

1 % Dimming

5 % Dimming

Hi-lume®

Compact SETM

18 W

1 2

A3 B3

— —

FDB-T418-120-1-S FDB-T418-120-2-S

.20 .42

26 W

1 2

A3 B3

— —

FDB-T426-120-1-S FDB-T426-120-2-S

.26 .50

18 W

1 2

A3 B3

— —

FDB-T418-120-1-S FDB-T418-120-2-S

.20 .42

26 W

1 2

A3 B3

HL3-T426-120-1-S FDB-T426-120-1-S — FDB-T426-120-2-S

.26 .50

32 W

1 2

A3 B3

HL3-T432-120-1-S FDB-T432-120-1-S — FDB-T432-120-2-S

.31 .59

42 W

1 2

B3 B3

— —

.39 .67

1/2 in Dia T4 4-Pin Triple-Tube

For the latest model numbers: www.lutron.com/ballasts

1/2 in Dia

10 % Dimming

FDB-T442-120-1-S FDB-T442-120-2-S

Ballast Current2 – Amps

4 Pin Electronic Lamp & Lamp Base Identification

18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)

26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)

32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)

42W • LAMP BASE: GX24Q-4 • LAMP INFORMATION: CFTR42W/GX24Q-4- 42W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F42TBX/4P) (SYLVANIA- CF42DT/E/IN)

1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 120. 2 Mounting studs standard. Delete suffix -S if mounting studs not desired. 14

Lutron

www.LUTRON.com


Lutron

®

|

Lamp Type T4 4-Pin Quad-Tube

Hi-lume and Compact SE 277 volt 3-wire dimming ballasts ®

Lamp Lamps Watts per Case (Length) Ballast Type1

1 % Dimming

5 % Dimming

Hi-lume®

Compact SETM

18 W

1 2

A3 B3

— —

FDB-T418-277-1-S FDB-T418-277-2-S

.08 .17

26 W

1 2

A3 B3

— —

FDB-T426-277-1-S FDB-T426-277-2-S

.12 .21

18 W

1 2

A3 B3

— —

FDB-T418-277-1-S FDB-T418-277-2-S

.08 .17

26 W

1 2

A3 B3

HL3-T426-277-1-S FDB-T426-277-1-S — FDB-T426-277-2-S

.12 .21

32 W

1 2

A3 B3

HL3-T432-277-1-S FDB-T432-277-1-S — FDB-T432-277-2-S

.13 .24

42 W

1 2

B3 B3

— —

.16 .29

1/2 in Dia T4 4-Pin Triple-Tube

For the latest model numbers: www.lutron.com/ballasts

1/2 in Dia

10 % Dimming

FDB-T442-277-1-S FDB-T442-277-2-S

Ballast Current2 – Amps

4 Pin Electronic Lamp & Lamp Base Identification

18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)

26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)

32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)

42W • LAMP BASE: GX24Q-4 • LAMP INFORMATION: CFTR42W/GX24Q-4- 42W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F42TBX/4P) (SYLVANIA- CF42DT/E/IN)

1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 277. 2 Standard with terminals. Leaded options available. Please consult Lutron. www.LUTRON.com

Lutron

15


Lutron

®

|

Tu-Wire 120 volt 2-wire dimming ballasts Lamp Lamps Watts per Case (Length) Ballast Type1

Lamp Type T4 4-Pin Quad-Tube

5 % Dimming 1 % Dimming Tu-Wire

10 % Dimming

Ballast Current2 – Amps

18 W

2

B4

2W-T418-120-2-S

.41

26 W

1 2

A4 B4

2W-T426-120-1-S5 2W-T426-120-2-S

.27 .53

18 W

2

B4

2W-T418-120-2-S

.41

26 W

1 2

A4 B4

2W-T426-120-1-S5 2W-T426-120-2-S

.27 .53

32 W

1 2

A4 B4

2W-T432-120-1-S5 2W-T432-120-2-S

.33 .58

1/2 in Dia T4 4-Pin Triple-Tube

For the latest model numbers: www.lutron.com/ballasts

®

1/2 in Dia

4 Pin Electronic Lamp & Lamp Base Identification

18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)

26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)

32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)

1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 120. 2 Standard with terminals. Leaded options available. Please consult Lutron. 3 Mounting studs standard. Delete suffix -S if mounting studs not desired. 4 One-lamp T4 models meet FCC Part 18 consumer requirements for residential use (FCC ID: JPZB001).

16

Lutron

www.LUTRON.com


Lutron

| ballast case dimensions

A

8-32 Threaded Stud 0.29 in (.736 mm)

A F

G

B

C I

H E

B A

B

G

D

8-32 Threaded Stud 0.29 in (.736 mm) F

C I

H E

D

A B C D E F G H I

4.20 in (107 mm) 1.00 in (25 mm) 3.00 in (76 mm) 4.90 in (124 mm) 4.60 in (117 mm) C-C (mounting centers) 2.00 in (51 mm) 1.08 in (27 mm) 1.60 in (41 mm) 1.39 in (35 mm)

A B C D E F G H I

6.00 in (152 mm) 1.00 in (25 mm) 3.00 in (76 mm) 6.75 in (171mm) 6.50 in (165 mm) C-C (mounting centers) 2.00 in (51 mm) 1.16 in (29 mm) 1.60 in (41 mm) 1.39 in (35 mm)

Proper ballast mounting is critical in providing effective grounding and for managing ballast heat. Please refer to the Lutron速 Fluorescent Dimming Systems Technical Guide (P/N 366-606) for detailed information.

www.LUTRON.com

Lutron

17


Lutron

®

| fluorescent dimming controls

Wallbox dimmers1 Vierti® Combines style and simplicity in a remarkably innovative control

Lyneo® Lx The simple, clean lines of the dimmer and matching switch ensure a coordinated look for your project

Maestro® NEW! The digital fade dimmer that coordinates with Claro® and Satin Colors® wallplates

www.lutron.com/lyneo

www.lutron.com/ maestro

www.lutron.com/vierti

Nova Ta® Classic, thin-profile linear-slide dimmer www.lutron.com/ novat

Vareo® Elegant thin-profile TapSwitchTM dimmer www.lutron.com/ vareo

Nova® Contractor’s choice in linearslide dimmers

Wireless remote controls1

www.lutron.com/ nova

Diva® Designer dimmer that matches your paddle switches www.lutron.com/ diva

RadioTouch® Wireless control of multiple lighting zones via radio frequency

Occupancy/vacancy sensing, motorized shade and A/V equipment control optional

Ideal for retrofit applications

Skylark® Original designer-style slide dimmer www.lutron.com/ skylark

Ariadni® Dimmer that matches your toggle switches

www.lutron.com/radiotouch

www.lutron.com/ ariadni

1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1.

18

Lutron

www.LUTRON.com


Preset scene controls1

GRAFIK Eye® QS NEW!

Spacer System®

Light and shade control in one unit

Controls lights with an IR control

Large, backlit engravable buttons

Up to five preset scenes

Built-in astronomical time clock and energy savings indicator

Easy upgrade for enclosed offices and conference rooms

Direct connections to sensors and other devices

Dims multiple sources

• • •

Select models directly control EcoSystem® and Hi-lume® 3D ballasts without an interface

www.lutron.com/spacersystem

www.lutron.com/grafikeyeqs

GRAFIK Eye® Create and recall 4-16 room lighting scenes

Optional accessories for wireless infrared (IR) remote control, remote scene selection, and more

Controls multiple sources

www.lutron.com/grafikeye

QuantumTM Solution NEW! Whole-building light and energy management Controls electric lights and shades from a central location; configures, monitors, analyzes, and reports on the lights for an entire building or campus. And the Quantum Green GlanceTM demonstrates how much energy your building is saving. www.lutron.com/quantum

1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. www.LUTRON.com

Lutron

19


Lutron

| select your fluorescent dimming controls

®

3-wire controls for Hi-lume and Compact SE ballasts1 ®

Nova Ta® Thin Profile Slide-To-Off Dimmer

Description single pole single pole single pole, 3-way, preset single pole, 3-way, preset

Ballast Voltage 120 V 277 V 120 V 277 V

Control Model Number NTF-10NTF-10-277NTF-103PNTF-103P-277-

Control Capacity 16 A 8A 8A 6A

Nova® Standard Profile Slide-To-Off Dimmer

single pole single pole single pole, 3-way, preset single pole, 3-way, preset

120 V 277 V 120 V 277 V

NF-10NF-10-277NF-103PNF-103P-277-

16 A 8A 8A 6A

Vareo® TapswitchTM/ Preset Slide Dimmer

single pole, 3-way

120 V

VF-10-

8 A2, 3

Diva® Paddle Switch/ Preset Slide Dimmer

single pole, 3-way single pole, 3-way single pole, 3-way single pole, 3-way

120 V 277 V 120 V 277 V

8A 6A 8A 6A

Skylark® Rocker Switch/ Preset Slide Dimmer

single pole single pole single pole, 3-way single pole, 3-way

120 V 277 V 120 V 277 V

DVF-103P-4 DVF-103P-277-4 DVSCF-103P-5 DVSCF-103P277-5 SF-10PSF-12P-277SF-103PSF-12P-277-3-

Ariadni® Toggle Switch/ Preset Slide Dimmer

single pole, 3-way single pole, 3-way

120 V 277 V

AYF-103PAYF-103P-277-

8A 6A

Vierti® Single-Touch Lighting Control

single pole, multi-location

120/277 V VTF-6AM-

single pole, 3-way, preset single pole, 3-way, preset

120 V 277 V

Control Family

NEW!

Lyneo® Lx Push-button Preset Slide NEW! Dimmer

LXF-103PLLXF-103PL-277-

8A 6A 8A 6A

6 A3, 6

8A 6A

1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Not to exceed 20 Lutron 3-wire dimming ballasts. 3 Must be derated if ganged. 4 Gloss finish. 5 Satin finish. 6 Not to exceed 60 Lutron 3-wire dimming ballasts. 20

Lutron

www.LUTRON.com


NEW!

Control Family Maestro® Digital Fade Tap Dimmer

RadioTouch® Wireless Multi-Zone Control Spacer System® Wireless Preset Scene Control

NEW!

GRAFIK Eye® QS Light and Shade Control System GRAFIK Eye Multi-Scene Preset Control

Description single, multi-location2 single, multi-location2 single, multi-location3 single, multi-location3 companion dimmer2 companion dimmer2 companion dimmer3 companion dimmer3 controller wallbox transmitter tabletop transmitter single pole single pole multi-location multi-location remote control control unit remote control (optional)

NEW!

Control Model Number MAF-6AMMAF-6AM-277MSCF-6AMMSCF-6AM-277MA-RMA-R-277MSC-ADMSC-AD-277RTA-RX-FRTA-WX-6 RTA-TX-

SPSF-6ASPSF-6A-277SPSF-6AM-7 SPSF-6AM-277-7 SPS-4IT-RP 120 / 277 V QSG-_8P120 GRX-IT

120 V 277 V 120 V 277 V

control unit 120 / 277 V GRX-310_9 GRX-IT-WH remote control (optional)

GRAFIK centralized lighting 5000TM /6000® /7000 TM control Lighting Control System QuantumTM Whole-building light and energy management

Ballast Voltage 120 V 277 V 120 V 277 V 120 V 277 V 120 V 277 V 120 / 277 V

lighting hub Q-manager PC

Control Capacity 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 8.3 A 8.3 A 8.3 A 8.3 A 16 A

6 A5. 6 6 A5. 6 6 A5. 6 6 A5, 6 16 A per power module 16 A per power module

120 / 277 V Contact your Lutron® representative for details

Contact your Lutron representative for details www.lutron.com/quantum

1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Gloss finish. 3 Satin finish. 4 Not to exceed 20 Lutron 3-wire dimming ballasts. 5 Must be derated if ganged. 6 Wallbox transmitter may be powered by 120 or 277 V. . 7 Also requires SPS-AD- or SPS-AD-277- for multi-location dimming (10 maximum). 8 Insert 3, 4, or 6 (number of zones); requires power module PHPM-3F-DV-WH. 9 Insert 2, 3, 4, or 6 (number of zones); requires power module PHPM-3F-DV-WH.

www.LUTRON.com

Lutron

21


Lutron

®

| select your fluorescent dimming controls

2-wire controls for Tu-Wire ballasts1 ®

Description single pole

Ballast Voltage 120 V

Control Model Number NTFTU-5A-

Control Capacity 5 A2

Nova® Standard Profile Slide-To-Off Dimmer

single pole

120 V

NFTU-5A-

5 A2

Diva® Paddle Switch/ Preset Slide Dimmer

single pole, 3-way

120 V

DVFTU-5A3P-

5 A2

Skylark® Rocker Switch/ Preset Slide Dimmer

single pole, 3-way

120 V

SFTU-5A3P-

5 A2

RadioTouch® Wireless Multi-Zone Control

controller wallbox transmitter tabletop transmitter

120 V

RTA-RX-F-3 RTA-WX-4 RTA-TX-

16 A

Spacer System® Wireless Preset Scene Control

single pole remote control

120 V

SPSFTU-5ASPS-4IT-RP

5 A2

GRAFIK Eye® QS control unit remote control (optional) Light and Shade Control System

120/277/ 347 V

QSG-_5P120 GRX-IT

16 A per unit, 6.7 A per zone

GRAFIK Eye Multi-Scene Preset Control GRAFIK 5000TM /6000® /7000TM Lighting Control System

control unit remote control (optional)

120 V

GRX-310_6 GRX-IT

16 A per unit, 6.7 A per zone

centralized lighting control

120/277 V Contact your Lutron representative for details

Control Family Nova Ta® Thin Profile Slide-To-Off Dimmer

NEW!

1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Minimum capacity: 2 ballasts. Must be derated if ganged. 3 Requires FDI-FTU-16A-120 interface. 4 Wallbox transmitter may be powered by 120 or 277 V. 5 Insert 3, 4, or 6 (number of zones). 6 Insert 2, 3, 4, or 6 (number of zones). 22

Lutron

www.LUTRON.com


Lutron

®

| dimming ballast reference guide for ordering Use the following summary as a quick reference to determine which Lutron dimming ballast you need to order in each product section.

Hi-lume 1% dimming Lut-H (HIL-HL3) ®

Dims T4 triple-tube compact lamps

Models:

Available in 120 V and 277 V

HL3-T426-120 (or 277)-1-S (for 26 W)

For 1-lamp 26 W and 32 W fixtures

HL3-T432-120 (or 277)-1-S (for 32 W)

• • •

Compact SE 5% dimming Lut-H (FDB) TM

Dims T4 quad- and triple-tube compact lamps

Models for quadand triple-tube lamps:

Available in 120 V and 277 V

FDB-T418-120 (or 277)-1-S (for 18 W 1-lamp)

Available for 1- and 2-lamp 18 W and 26 W quad-tubes

FDB-T418-120 (or 277)-2-S (for 18 W 2-lamp)

• •

Available for 1- and 2-lamp 18, 26, 32 and 42 W triple-tube lamps

FDB-T426-120 (or 277)-1-S (for 26 W 1-lamp) FDB-T426-120 (or 277)-2-S (for 26 W 2-lamp) Models for triple-tube lamps only: FDB-T432-120 (or 277)-1-S (for 32 W 1-lamp) FDB-T432-120 (or 277)-2-S (for 32 W 2-lamp) FDB-T442-120 (or 277)-1-S (for 42 W 1-lamp) FDB-T442-120 (or 277)-2-S (for 42 W 1-lamp)

Tu-Wire 5% dimming Lut-H (Tu-Wire) ®

Dims T4 quad- and triple-tube compact lamps

Models for quadand triple-tube lamps:

Available in 120 V

2W-T418-120-2-S (for 18 W 2-lamp)

Available for 2-lamp 18 W, and 1- and 2-lamp 26 W quad-tubes

2W-T426-120-1-S (for 26 W 1-lamp)

• •

Available for 2-lamp 18 W, and 1- and 2-lamp 26 W and 32 W triple-tube lamps

2W-T426-120-2-S (for 26 W 2-lamp)

Models for triple-tube lamps only: 2W-T432-120-1-S (for 32 W 1-lamp) 2W-T432-120-2-S (for 32 W 2-lamp)

www.LUTRON.com

Lutron

23


no. 1 in recessed lighting

t a b l e

o f

c o n t e n t s

vertical architectural compact fluorescent downlighting

HV4PL . . . . . . . . . . . . . . . . 30 4” Vertical Architectural Compact Fluorescent Downlighting

HV6PL . . . . . . . . . . . . . . . . 36 6” Vertical Architectural Compact Fluorescent Downlighting

HV8PL . . . . . . . . . . . . . . . . 44 8” Vertical Architectural Compact Fluorescent Downlighting

HV4PLIC-AT . . . . . . . . . . . . 31 4” Vertical Architectural Compact Fluorescent IC Downlighting

HVR6PL . . . . . . . . . . . . . . . 37 6” Vertical Architectural Compact Fluorescent Remodel Downlighting

HVR8PL . . . . . . . . . . . . . . . 45 8” Vertical Architectural Compact Fluorescent Remodel Downlighting

HVR4PL . . . . . . . . . . . . . . . 32 4” Vertical Architectural Compact Fluorescent Remodel Downlighting

HVJ6PL . . . . . . . . . . . . . . . 38 6” Vertical Architectural Compact Fluorescent Retrofit Downlighting

HVJ8PL . . . . . . . . . . . . . . . 46 8” Vertical Architectural Compact Fluorescent Retrofit Downlighting

HVJ4PL . . . . . . . . . . . . . . . 33 4” Vertical Architectural Compact Fluorescent Retrofit Downlighting

BHVR6PL . . . . . . . . . . . . . . 39 6” Vertical Architectural Compact Fluorescent Downlighting

8” Vertical Trims . . . . . . . 47

4” Vertical Trims . . . . . . . 33

6” Vertical Trims . . . . . . . 40

HV10PL . . . . . . . . . . . . . . . 52 10” Vertical Architectural Compact Fluorescent Downlighting 10” Vertical Trims . . . . . . 53

horizontal architectural compact fluorescent downlighting

HH4SQPL . . . . . . . . . . . . . . 28 4” Square Architectural Compact Fluorescent Downlighting 4” Square Trims . . . . . . . . 29

HS6PL . . . . . . . . . . . . . . . . 54 6” Horizontal Architectural Compact Fluorescent Shallow Downlighting 6” Shallow Trims . . . . . . . 55

HS8PL . . . . . . . . . . . . . . . . 68 8” Horizontal Architectural Compact Fluorescent Shallow Downlighting 8” Shallow Trims . . . . . . . 69

HH6PL . . . . . . . . . . . . . . . . 58 6” Horizontal Architectural Compact Fluorescent Downlighting

HH8PL . . . . . . . . . . . . . . . . 72 8” Horizontal Architectural Compact Fluorescent Downlighting

HH6PLIC-AT . . . . . . . . . . . . 59 6” Horizontal Architectural Compact Fluorescent IC Downlighting

HHR8PL . . . . . . . . . . . . . . . 73 8” Horizontal Architectural Compact Fluorescent Remodel Downlighting

HH10PL . . . . . . . . . . . . . . . 80 10” Horizontal Architectural Compact Fluorescent Downlighting 10” Horizontal Trims . . . . 81

BHHR6PL . . . . . . . . . . . . . . 60 6” Horizontal Architectural Compact Fluorescent Downlighting HHR6PL . . . . . . . . . . . . . . . 61 6” Horizontal Architectural Compact Fluorescent Remodel Downlighting HHR6PL . . . . . . . . . . . . . . . 62 6” Horizontal Architectural Compact Fluorescent Retrofit Downlighting

HHR8PL . . . . . . . . . . . . . . . 74 8” Horizontal Architectural Compact Fluorescent Retrofit Downlighting 8” Horizontal Trims . . . . . 75

sloped ceiling adapter

MSCA Maxilume Sloped Ceiling Adapter MSCA6 (6”) . . . . . . . . . . . . . 84 MSCA8 (8”) . . . . . . . . . . . . . 84

6” Horizontal Trims . . . . . 63

24

www.iuseelite.com • www.maxilume.com


architectural lighting

t a b l e

o f

c o n t e n t s

architectural compact fluorescent lensed wall wash downlighting

HW6PL . . . . . . . . . . . . . . . 82 6” Architectural Compact Fluorescent Lensed Wall Wash Downlighting

HW8PL . . . . . . . . . . . . . . . 83 8” Architectural Compact Fluorescent Lensed Wall Wash Downlighting

compact fluorescent downlighting

HV4PLIC-AT . . . . . . . . . . . . 88 4” Vertical Architectural Compact Fluorescent IC Downlighting 4” Vertical Trims . . . . . . . 89 B4PL-E . . . . . . . . . . . . . . . . 92 4” Miniature Compact Fluorescent Non-IC Downlighting B4PLR-E . . . . . . . . . . . . . . 93 4” Miniature Compact Fluorescent Non-IC Remodel Downlighting 4” Compact Fluorescent Trims . . . . . . . . . . . . . . . . . 94

B5PLIC-E . . . . . . . . . . . . . . 96 5” Compact Fluorescent IC Downlighting

B6PLIC-E . . . . . . . . . . . . . 102 6” Compact Fluorescent IC Downlighting

B36PLIC-E . . . . . . . . . . . . 112 6” Compact Fluorescent Slope Ceiling IC Downlighting

B5PLRIC-E . . . . . . . . . . . . . 97 5” Compact Fluorescent IC Remodel Downlighting

B6PLRIC-E . . . . . . . . . . . . 103 6” Compact Fluorescent IC Remodel Downlighting

B36PLRIC-E . . . . . . . . . . . 113 6” Compact Fluorescent Slope Ceiling IC Remodel Downlighting

B5PL-E . . . . . . . . . . . . . . . . 98 5” Compact Fluorescent Non-IC Downlighting

B6PL-E . . . . . . . . . . . . . . . 104 6” Compact Fluorescent Non-IC Downlighting

6” Slope Trims . . . . . . . . 114

B5PLR-E . . . . . . . . . . . . . . 99 5” Compact Fluorescent Non-IC Remodel Downlighting

B6PLR-E . . . . . . . . . . . . . 105 6” Compact Fluorescent Non-IC Remodel Downlighting

5” Compact Fluorescent Trims . . . . . . . . . . . . . . . . 101

B6PLIC-26 or 32-E . . . . . 106 6” Double Wall Compact Fluorescent IC Downlighting 6” Compact Fluorescent Trims . . . . . . . . . . . . . . . . 107

emergency battery pack

bodine b94c-2 . . . . . . . . 117

www.iuseelite.com • www.maxilume.com

iota i42em-j . . . . . . . . . 117

iota i42em-r-j . . . . . . . 117

25


ARCHITECTURAL LIGHTING available in

4” , 6 ” , 8 ” , a n d 1 0 ” architectural downlighting & trims

1 2

3 4 5 6

26

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


ARCHITECTURAL LIGHTING

1

MOUNTING BRACKET Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 26”. Mounting brackets may be adjusted vertically from inside the housing.

2

LAMP HOLDER Die-formed aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

3

MOUNTING FRAME Die-formed construction for maximum heat dissipation and rust protection.

4

JUNCTION BOX/BALLAST UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5

LENS Choice of either tempered clear, frosted, fresnel or prismatic lens fastened with two torsion springs for easy re-lamping. UL and ETL listed for wet or damp location.

6

REFLECTOR .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

Available sloped ceiling adapter if required. • MSCA-6 • MSCA-8

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

27


hh4sqpl square fluorescent series 4” square fluorescent downlighting

A. Min. Height = 5-1/2” B. Trim Aperture = 4-1/2” c. Cut-out = 5-1/2” d. Trim Outside Dia. = 5-3/4” e. Width = 7-3/4” f. Length = 7-1/8” g. Max. Length = 10”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

4”

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation.

7. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location.

4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

Hh4sqPL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

hl3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Reflector

emg 750

4106-Reflector

cl

emg 1300

4604-Reflector with Prismatic Glass Lens

shz

emg-d-750

4614-Reflector with Frosted Glass Lens

wt

ice-1300

4615-Reflector with Tempered Clear Glass

w

4607-Wall Wash Reflector with Lens

mb

Other Options

Ring WH - Self-Flange White

REFLECTOR RING CL Clear WH Self-Flange White WT Wheat Standard on all trims MB Black W White SHZ Satin Haze

fuse rif

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: Hh4sqPL-1X18-FDB-T418-120-EMG 750-4106-CL-WH 28

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


4” square fluorescent trims 4601-CL

4604-CL

REFLECTOR

REFLECTOR w/ prismatic glass lens

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”

A = 3-1/8” B = 5-3/4” C = 4-5/8”

4614-CL

4615-CL

REFLECTOR w/ Frosted Glass Lens

REFLECTOR w/ tempered clear glass

4” REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”

A = 3-1/8” B = 5-3/4” C = 4-5/8”

4607-CL wall wash reflector with lens

REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

29


hV4pl fluorescent series 4” vertical fluorescent downlighting

A. Min. Height = 7-1/2” Max. Height =8-1/2” (See trim heights for details)

B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

4”

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HV4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

4101-Reflector

4114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

4102-Baffle Reflector

4115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

4103-Reflector/Fresnel Glass Lens

4116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

4104-Reflector/Prismatic Glass Lens

4117-Baffle/Prismatic Plastic Lens

w

frost

4105-Baffle/Fresnel Glass Lens

4118-Reflector/Tempered Clear Plastic

mb

4106-Baffle/Prismatic Glass Lens

4119-Baffle/Tempered Clear Plastic

fuse

4107-Wall Wash Reflector

4109-Deco Glass Ring

rif

4108-Crossblade Reflector

4110-Double Ring

4112-Baffle/Frosted Glass Lens

4111-Triple Ring

Other Options

4113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH 30

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hv4plic-at fluorescent series 4” vertical fluorescent ic downlighting

A. Min. Height = 7-3/4” B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 8” f. Length = 12-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

4”

HV4PLic-at - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

------

-------

-------

-------

-------

-------

------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

4101-Reflector

4114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

4102-Baffle Reflector

4115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

4103-Reflector/Fresnel Glass Lens

4116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

4104-Reflector/Prismatic Glass Lens

4117-Baffle/Prismatic Plastic Lens

w

frost

4105-Baffle/Fresnel Glass Lens

4118-Reflector/Tempered Clear Plastic

mb

4106-Baffle/Prismatic Glass Lens

4119-Baffle/Tempered Clear Plastic

fuse

4107-Wall Wash Reflector

4109-Deco Glass Ring

rif

4108-Crossblade Reflector

4110-Double Ring

4112-Baffle/Frosted Glass Lens

4111-Triple Ring

Other Options

4113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV4PLIc-at-1X18-FDB-T418-120-EMG 750-4101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

31


hVr4pl fluorescent series 4” vertical fluorescent remodel downlighting

A. Min. Height = 7-1/4” Max. Height =8-1/2” (See trim heights for details)

B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 7-1/2” f. Length = 11-5/8” g. Flange = 2-1/4” DESCRIPTION:

TRIMS:

Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

4”

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HVR4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

4101-Reflector

4114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

4102-Baffle Reflector

4115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

4103-Reflector/Fresnel Glass Lens

4116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

4104-Reflector/Prismatic Glass Lens

4117-Baffle/Prismatic Plastic Lens

w

frost

4105-Baffle/Fresnel Glass Lens

4118-Reflector/Tempered Clear Plastic

mb

4106-Baffle/Prismatic Glass Lens

4119-Baffle/Tempered Clear Plastic

fuse

4107-Wall Wash Reflector

4109-Deco Glass Ring

rif

4108-Crossblade Reflector

4110-Double Ring

4112-Baffle/Frosted Glass Lens

4111-Triple Ring

Other Options

4113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVR4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH 32

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hvj4pl fluorescent series 4” vertical fluorescent retrofit downlighting

A. Min. Height = 7-1/4” Max. Height =8-1/2” (See trim heights for details)

B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2”

universal n installatio

(frame not included)

DESCRIPTION:

TRIMS:

Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 4-3/8” aperture.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

4”

HVJ4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

4101-Reflector

4114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

4102-Baffle Reflector

4115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

4103-Reflector/Fresnel Glass Lens

4116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

4104-Reflector/Prismatic Glass Lens

4117-Baffle/Prismatic Plastic Lens

w

frost

4105-Baffle/Fresnel Glass Lens

4118-Reflector/Tempered Clear Plastic

mb

4106-Baffle/Prismatic Glass Lens

4119-Baffle/Tempered Clear Plastic

fuse

4107-Wall Wash Reflector

4109-Deco Glass Ring

rif

4108-Crossblade Reflector

4110-Double Ring

4112-Baffle/Frosted Glass Lens

4111-Triple Ring

Other Options

4113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVJ4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

33


4” vertical fluorescent trims

4”

4101-CL

4102-WH-CL

4107-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

4103-CL

4105-P

4114-CL

REFLECTOR w/ fresnel glass lens

baffle w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

4116-CL

4117-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

4121-CL

4122-CL

4123-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

4118-WT reflector w/ tempered clear plastic

trim o. d.: 5-1/2” REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh

new

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

4127-CL

4109-CL

4110-CL

geo deco ring glass

deco glass reflector

double ring glass

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

RING finish: Wh, shz

RING finish: Wh

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

new

34

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


4” vertical fluorescent trims 4108-CL crossblade REFLECTOR

trim o. d.: 5-1/2” REFlector finish: CL, Wt, SHZ, w RING finish: Wh

4104-CL

4106-WH

REFLECTOR w/ prismatic glass lens

baffle w/ prismatic glass lens

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

4115-WT

4113-WH

baffle w/ frosted glass lens

reflector w/ tempered clear glass

baffle w/ tempered clear glass

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

baffle finish: wh, p

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

4112-WH

4119-WH baffle w/ tempered clear plastic

4”

trim o. d.: 5-1/2” baffle finish: wh, p RING finish: Wh

4124-CL

4125-CL

4126-CL

geo deco ring glass

central etched float glass

diffusing screen wall wash glass

new

new

new

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

4111-CL triple ring glass

REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh, shz GLASS finish: Blue, red, green, frost

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

35


hV6pl fluorescent series 6” vertical fluorescent downlighting

A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6”

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HV6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6101-Reflector

6114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6102-Baffle Reflector

6115-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

6103-Reflector/Fresnel Glass Lens

6116-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

6104-Reflector/Prismatic Glass Lens

6117-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

6105-Baffle/Fresnel Glass Lens

6118-Reflector/Tempered Clear Plastic

mb

intg-d-750

6106-Baffle/Prismatic Glass Lens

6119-Baffle/Tempered Clear Plastic

ice-1300

6107-Wall Wash Reflector

6109-Deco Glass Ring

Other Options

6108-Crossblade Reflector

6110-Double Ring

fuse

6112-Baffle/Frosted Glass Lens

6111-Triple Ring

rif

6113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH 36

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hvR6pl fluorescent series 6” vertical fluorescent remodel downlighting

A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 1-1/2”

DESCRIPTION:

TRIMS:

Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

6”

HV6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6101-Reflector

6114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6102-Baffle Reflector

6115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6103-Reflector/Fresnel Glass Lens

6116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6104-Reflector/Prismatic Glass Lens

6117-Baffle/Prismatic Plastic Lens

w

frost

6105-Baffle/Fresnel Glass Lens

6118-Reflector/Tempered Clear Plastic

mb

6106-Baffle/Prismatic Glass Lens

6119-Baffle/Tempered Clear Plastic

fuse

6107-Wall Wash Reflector

6109-Deco Glass Ring

rif

6108-Crossblade Reflector

6110-Double Ring

6112-Baffle/Frosted Glass Lens

6111-Triple Ring

Other Options

6113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVR6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

37


hVj6pl fluorescent series 6” vertical fluorescent retrofit downlighting

A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8”

universal n installatio

(frame not included)

DESCRIPTION: Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 6-3/4” aperture. 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing. 2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6”

TRIMS: 3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 4. GROVE BAFFLE - One-piece aluminum with concentric rings. 5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HVJ6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

6101-Reflector

6114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6102-Baffle Reflector

6115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6103-Reflector/Fresnel Glass Lens

6116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6104-Reflector/Prismatic Glass Lens

6117-Baffle/Prismatic Plastic Lens

w

frost

6105-Baffle/Fresnel Glass Lens

6118-Reflector/Tempered Clear Plastic

mb

6106-Baffle/Prismatic Glass Lens

6119-Baffle/Tempered Clear Plastic

fuse

6107-Wall Wash Reflector

6109-Deco Glass Ring

rif

6108-Crossblade Reflector

6110-Double Ring

6112-Baffle/Frosted Glass Lens

6111-Triple Ring

Other Options

6113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVJ6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH 38

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


bhvr6pl fluorescent series 6” vertical fluorescent downlighting

A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

6”

BHVR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6101-Reflector

6114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6102-Baffle Reflector

6115-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

6103-Reflector/Fresnel Glass Lens

6116-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

6104-Reflector/Prismatic Glass Lens

6117-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

6105-Baffle/Fresnel Glass Lens

6118-Reflector/Tempered Clear Plastic

mb

intg-d-750

6106-Baffle/Prismatic Glass Lens

6119-Baffle/Tempered Clear Plastic

ice-1300

6107-Wall Wash Reflector

6109-Deco Glass Ring

Other Options

6108-Crossblade Reflector

6110-Double Ring

fuse

6112-Baffle/Frosted Glass Lens

6111-Triple Ring

rif

6113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: BHVR6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

39


6” vertical fluorescent trims

6”

6108-CL

6101-CL

6102-WH-CL

6107-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

6103-CL

6105-P

6114-CL

6112-WH

REFLECTOR w/ fresnel glass lens

baffle w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

baffle w/ frosted glass lens

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6116-CL

6117-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

6118-WT

6119-WH

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

6121-CL

6122-CL

6123-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

new

6124-CL geo deco ring glass

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6127-CL

6109-CL

6110-CL

6111-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

RING finish: Wh

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

geo deco ring glass

new

40

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” vertical fluorescent trims 6104-CL

6106-WH

REFLECTOR w/ prismatic glass lens

baffle w/ prismatic glass lens

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

6115-WT

6113-WH

reflector w/ tempered clear glass

baffle w/ tempered clear glass

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

6”

6125-CL

6126-CL

central etched float glass

diffusing screen wall wash glass

new

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6101-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

41


photometric data hv6pl-1x13-e-6101cl / hvr6pl-1x13-e-6101cl / hvj6pl1x13-e-6101cl- / bhvr6pl-1x13-e-6101cl lamp: philips pl-c 13w/27/4p

lumens: 900

Candle Power Distribution (Candelas)

Zonal Lumens Summary Zone Lumens 0-300 261.65 0-400 393.43 0 0-60 581.48 0 0-90 610.98 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 610.98

test no.: lli 0205-10f

total luminaire efficiency: 67.9%

%Lamp 29.1 43.7 64.6 67.9 0 0 0 0 67.9

%Fixt 42.8 64.4 95.2 100 0 0 0 0 100

spacing criteria: 1.14

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

11021 4279 478 337 540

0-10 . . . . . . . . . . 32.28 10-20 . . . . . . . . . 100.8 20-30 . . . . . . . . . 128.57 30-40 . . . . . . . . . 131.78 40-50 . . . . . . . . . 55.76 50-60 . . . . . . . . . 24.88 60-70 . . . . . . . . . 2.94 70-80 . . . . . . . . . 1.68 80-90 . . . . . . . . . 0

Total Luminaire Efficiency = 67.9%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

26.0 11.6 6.5 4.2 2.9

8.9’ 13.3’ 17.8’ 22.2’ 26.7’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 81 81 81 81 1 76 74 71 69 2 71 66 63 60 3 66 60 56 52 4 61 55 50 46 5 57 50 45 41 6 53 46 40 37 7 50 42 37 33 8 47 39 34 30 9 44 36 31 27 10 41 33 28 25 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

79 79 79 79 74 72 70 68 69 65 62 59 64 59 55 52 60 54 49 46 56 49 44 41 52 45 40 37 49 41 36 33 46 38 33 30 43 35 31 27 40 33 28 25 RW - Wall Reflectance

75 69 63 57 52 48 44 40 37 35 32

72 67 61 56 51 47 43 39 37 34 32

69 64 59 54 49 45 42 39 36 33 31

68 61 54 48 43 38 35 31 28 26 24

75 68 60 54 48 44 40 36 33 30 28

75 66 58 51 45 40 36 33 30 27 25

72 65 59 53 47 43 39 36 33 30 28

72 64 57 50 45 40 36 33 30 27 25

69 63 57 51 47 42 38 35 32 30 28

69 62 55 49 44 40 36 32 30 27 25

hv6pl-1x18-e-6101cl / hvr6pl-1x18-e-6101cl / hvj6pl1x18-e-6101cl- / bhvr6pl-1x18-e-6101cl lamp: philips pl-c 18w/27/4p/ALTO Candle Power Distribution (Candelas)

lumens: 1250

Zone Lumens 0-300 363.43 0-400 546.47 0-600 807.67 0-900 848.65 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 848.65

6”

test no.: lli 0205-10F

total luminaire efficiency: 67.9%

Zonal Lumens Summary %Lamp 29.1 43.7 64.6 67.9 0 0 0 0 67.9

%Fixt 42.8 64.4 95.2 100 0 0 0 0 100

spacing criteria: 1.14

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

15309 5943 664 468 755

0-10 . . . . . . . . . . 44.83 10-20 . . . . . . . . . 140.01 20-30 . . . . . . . . . 178.58 30-40 . . . . . . . . . 183.05 40-50 . . . . . . . . . 183.75 50-60 . . . . . . . . . 77.45 60-70 . . . . . . . . . 34.55 70-80 . . . . . . . . . 4.08 80-90 . . . . . . . . . 2.35

Total Luminaire Efficiency = 67.9%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 96 Degrees

Distance to Plane

36.1 16.1 9.0 5.8 4.0

8.9’ 13.3’ 17.8’ 22.2’ 26.7’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

42

RC RW

R oom C av i t y R a t io

4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 81 81 81 81 1 76 74 71 69 2 71 66 63 60 3 66 60 56 52 4 61 55 50 46 5 57 50 45 41 6 53 46 40 37 7 50 42 37 33 8 47 39 34 30 9 44 36 31 27 10 41 33 28 25 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

79 79 79 79 74 72 70 68 69 65 62 59 64 59 55 52 60 54 49 46 56 49 44 41 52 45 40 37 49 41 36 33 46 38 33 30 43 35 31 27 40 33 28 25 RW - Wall Reflectance

75 69 63 57 52 48 44 40 37 35 32

72 67 61 56 51 47 43 39 37 34 32

69 64 59 54 49 45 42 39 36 33 31

68 61 54 48 43 38 35 31 28 26 24

75 68 60 54 48 44 40 36 33 30 28

75 66 58 51 45 40 36 33 30 27 25

72 65 59 53 47 43 39 36 33 30 28

72 64 57 50 45 40 36 33 30 27 25

Candela Tabulation 0 0 . . . . . . . . . 416.01 1 . . . . . . . . . 417.67 3 . . . . . . . . . 423.56 5 . . . . . . . . . 424.66 7 . . . . . . . . . 417.39 9 . . . . . . . . . 402.85 11 . . . . . . . . 384.67 13 . . . . . . . . 367.79 15 . . . . . . . . 352.76 17 . . . . . . . . 340.99 19.5 . . . . . . 324.51 22.5 . . . . . . 307.79 25.5 . . . . . . 296.3 29 . . . . . . . . 282.91 33 . . . . . . . . 262.77 37.5 . . . . . . 230.01 42.5 . . . . . . 182.29 47.5 . . . . . . 125.52 55 . . . . . . . . 48.47 65 . . . . . . . . 3.99 75 . . . . . . . . 1.72 85 . . . . . . . . 85 0.93 90 . . . . . . . . 0

69 63 57 51 47 42 38 35 32 30 28

69 62 55 49 44 40 36 32 30 27 25

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

Candela Tabulation 0 0 . . . . . . . . . 577.84 1 . . . . . . . . . 580.14 3 . . . . . . . . . 588.33 5 . . . . . . . . . 589.86 7 . . . . . . . . . 579.75 9 . . . . . . . . . 559.56 11 . . . . . . . . 534.3 13 . . . . . . . . 510.86 15 . . . . . . . . 489.99 17 . . . . . . . . 473.64 19.5 . . . . . . 450.74 22.5 . . . . . . 427.52 25.5 . . . . . . 411.56 29 . . . . . . . . 392.96 33 . . . . . . . . 364.98 37.5 . . . . . . 319.48 42.5 . . . . . . 253.21 47.5 . . . . . . 174.34 55 . . . . . . . . 67.32 65 . . . . . . . . 5.54 75 . . . . . . . . 2.39 85 . . . . . . . . 1.3 90 . . . . . . . . 0


photometric data hv6pl-1x26-e-6101cl / hvr6pl-1x26-e-6101cl / hvj6pl1x26-e-6101cl- / bhvr6pl-1x26-e-6101cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 1800

Zonal Lumens Summary Zone Lumens 0-300 385.04 0-400 609.75 0 0-60 1008.38 0 0-90 1157.4 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1157.4

test no.: lli 1204-14d

total luminaire efficiency: 64.3%

%Lamp 21.4 33.9 56 64.3 0 0 0 0 64.3

%Fixt 33.3 52.7 87.1 100 0 0 0 0 100

spacing criteria: 1.44

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

23041 16979 6851 1017 1208

0-10 . . . . . . . . . . 35.48 10-20 . . . . . . . . . 139.65 20-30 . . . . . . . . . 209.91 30-40 . . . . . . . . . 224.71 40-50 . . . . . . . . . 251.2 50-60 . . . . . . . . . 147.42 60-70 . . . . . . . . . 113.82 70-80 . . . . . . . . . 30.88 80-90 . . . . . . . . . 4.32

Total Luminaire Efficiency = 64.3%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

27.0 12.0 6.8 4.3 3.0

11.0’ 16.5’ 22.0’ 27.5’ 33.0’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 108 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 77 77 77 77 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 20 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

75 75 75 75 69 67 65 63 64 59 56 53 59 53 49 45 54 47 43 39 50 43 38 34 46 39 34 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance

71 64 57 51 46 41 37 34 31 29 27

68 62 55 49 44 40 36 33 31 28 26

66 60 53 48 43 39 35 32 30 28 26

64 56 48 41 36 32 28 25 22 20 18

71 63 54 47 42 37 33 30 27 24 22

71 61 52 44 38 33 30 26 24 21 19

68 60 53 46 41 36 32 29 26 24 22

68 59 51 43 38 33 29 26 23 21 19

66 58 51 45 40 36 32 29 26 24 22

66 57 49 43 37 33 29 26 23 21 19

hv6pl-1x32-e-6101cl / hvr6pl-1x32-e-6101cl / hvj6pl1x32-e-6101cl- / bhvr6pl-1x32-e-6101cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 2400

Zone Lumens 0-300 513.19 0-400 812.61 0-600 1343.89 0-900 1541.5 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1541.5

test no.: lli 1204-14a

total luminaire efficiency: 64.2%

Zonal Lumens Summary %Lamp 21.4 33.9 56 64.2 0 0 0 0 64.2

%Fixt 33.3 52.7 87.2 100 0 0 0 0 100

spacing criteria: 1.44

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

30709 22578 9093 1220 1812

0-10 . . . . . . . . . . 47.3 10-20 . . . . . . . . . 186.17 20-30 . . . . . . . . . 279.72 30-40 . . . . . . . . . 299.42 40-50 . . . . . . . . . 334.82 50-60 . . . . . . . . . 196.46 60-70 . . . . . . . . . 151.29 70-80 . . . . . . . . . 40.65 80-90 . . . . . . . . . 5.68

Total Luminaire Efficiency = 64.2%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 108 Degrees

Distance to Plane

36.0 16.0 9.0 5.8 4.0

11.0’ 16.5’ 22.0’ 27.5’ 33.0’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

RC RW

R oom C av i t y R a t io

4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 76 76 76 76 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 19 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

75 75 75 75 69 67 65 63 64 59 56 53 58 53 49 45 54 47 43 39 50 43 38 34 46 39 33 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance

71 64 57 51 46 41 37 34 31 29 27

68 62 55 49 44 40 36 33 31 28 26

66 59 53 48 43 39 35 32 30 28 26

64 56 48 41 36 32 28 25 22 20 18

71 62 54 47 42 37 33 30 27 24 22

71 61 52 44 38 33 30 26 24 21 19

68 60 53 46 41 36 32 29 26 24 22

68 59 51 43 38 33 29 26 23 21 19

66 58 51 45 40 36 32 29 26 24 22

66 57 49 43 37 33 29 26 23 21 19

hv6pl-1x42-e-6101cl / hvr6pl-1x42-e-6101cl / hvj6pl1x42-e-6101cl- / bhvr6pl-1x42-e-6101cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 3200

Zone Lumens 0-300 684.53 0-400 1083.79 0 0-60 1792.05 0 0-90 2056.19 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2056.19

222

665

444

%Lamp 21.4 33.9 56 64.3 0 0 0 0 64.3

%Fixt 33.3 52.7 87.2 100 0 0 0 0 100

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

40946 30103 12207 1627 2416

0-10 . . . . . . . . . . 63.1 10-20 . . . . . . . . . 248.29 20-30 . . . . . . . . . 373.14 30-40 . . . . . . . . . 399.26 40-50 . . . . . . . . . 446.42 50-60 . . . . . . . . . 261.84 60-70 . . . . . . . . . 202.03 70-80 . . . . . . . . . 54.55 80-90 . . . . . . . . . 7.57

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 108 Degrees

Distance to Plane

48.1 21.4 12.0 7.7 5.3

11.0’ 16.5’ 22.0’ 27.5’ 33.0’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

RC RW

R oom Ca vi t y Ra t i o

4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 76 76 76 76 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 19 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

75 75 75 75 69 67 65 63 64 59 56 53 58 53 49 45 54 47 43 39 50 43 38 34 46 39 33 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance

71 64 57 51 46 41 37 34 31 29 27

68 62 55 49 44 40 36 33 31 28 26

66 59 53 48 43 39 35 32 30 28 26

64 56 48 41 36 32 28 25 22 20 18

71 62 54 47 42 37 33 30 27 24 22

71 61 52 44 38 33 30 26 24 21 19

68 60 53 46 41 36 32 29 26 24 22

68 59 51 43 38 33 29 26 23 21 19

6”

spacing criteria: 1.44

Total Luminaire Efficiency = 64.3%

887

Candela Tabulation 0 0 . . . . . . . . . 576 1 . . . . . . . . . 577 3 . . . . . . . . . 587 5 . . . . . . . . . 603 7 . . . . . . . . . 620 9 . . . . . . . . . 636 11 . . . . . . . . 649 13 . . . . . . . . 657 15 . . . . . . . . 660 17 . . . . . . . . 663 19.5 . . . . . . 665 22.5 . . . . . . 662 25.5 . . . . . . 656 29 . . . . . . . . 634 33 . . . . . . . . 594 37.5 . . . . . . 535 42.5 . . . . . . 458 47.5 . . . . . . 367 55 . . . . . . . . 246 65 . . . . . . . . 73 75 . . . . . . . . 6 85 . . . . . . . . 3 90 . . . . . . . . 0

test no.: lli 1204-14e

total luminaire efficiency: 64.3%

Zonal Lumens Summary

Candela Tabulation 0 0 . . . . . . . . . 432 1 . . . . . . . . . 433 3 . . . . . . . . . 441 5 . . . . . . . . . 452 7 . . . . . . . . . 465 9 . . . . . . . . . 477 11 . . . . . . . . 487 13 . . . . . . . . 493 15 . . . . . . . . 495 17 . . . . . . . . 497 19.5 . . . . . . 499 22.5 . . . . . . 497 25.5 . . . . . . 492 29 . . . . . . . . 476 33 . . . . . . . . 446 37.5 . . . . . . 401 42.5 . . . . . . 344 47.5 . . . . . . 275 55 . . . . . . . . 185 65 . . . . . . . . 55 75 . . . . . . . . 5 85 . . . . . . . . 2 90 . . . . . . . . 0

66 58 51 45 40 36 32 29 26 24 22

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

66 57 49 43 37 33 29 26 23 21 19

Candela Tabulation 0 0 . . . . . . . . . 769 1 . . . . . . . . . 770 3 . . . . . . . . . 784 5 . . . . . . . . . 804 7 . . . . . . . . . 827 9 . . . . . . . . . 849 11 . . . . . . . . 866 13 . . . . . . . . 876 15 . . . . . . . . 880 17 . . . . . . . . 884 19.5 . . . . . . 887 22.5 . . . . . . 883 25.5 . . . . . . 875 29 . . . . . . . . 846 33 . . . . . . . . 792 37.5 . . . . . . 713 42.5 . . . . . . 611 47.5 . . . . . . 489 55 . . . . . . . . 328 65 . . . . . . . . 98 75 . . . . . . . . 8 85 . . . . . . . . 4 90 . . . . . . . . 0

43


hV8pl fluorescent series 8” vertical fluorescent downlighting

A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)

B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

8”

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HV8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

8101-Reflector

8114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8102-Baffle Reflector

8115-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

8103-Reflector/Fresnel Glass Lens

8116-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

8104-Reflector/Prismatic Glass Lens

8117-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

8105-Baffle/Fresnel Glass Lens

8118-Reflector/Tempered Clear Plastic

mb

intg-d-750

8106-Baffle/Prismatic Glass Lens

8119-Baffle/Tempered Clear Plastic

ice-1300

8107-Wall Wash Reflector

8109-Deco Glass Ring

Other Options

8108-Crossblade Reflector

8110-Double Ring

fuse

8112-Baffle/Frosted Glass Lens

8111-Triple Ring

rif

8113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH 44

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hvR8pl fluorescent series 8” vertical fluorescent remodel downlighting

A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)

B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 2-1/4” DESCRIPTION:

TRIMS:

Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

8”

HVR8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

8101-Reflector

8114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8102-Baffle Reflector

8115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

8103-Reflector/Fresnel Glass Lens

8116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

8104-Reflector/Prismatic Glass Lens

8117-Baffle/Prismatic Plastic Lens

w

frost

8105-Baffle/Fresnel Glass Lens

8118-Reflector/Tempered Clear Plastic

mb

8106-Baffle/Prismatic Glass Lens

8119-Baffle/Tempered Clear Plastic

fuse

8107-Wall Wash Reflector

8109-Deco Glass Ring

rif

8108-Crossblade Reflector

8110-Double Ring

8112-Baffle/Frosted Glass Lens

8111-Triple Ring

Other Options

8113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVR8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

45


hVJ8pl fluorescent series 8” vertical fluorescent retrofit downlighting

A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)

B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8”

universal n installatio

(frame not included)

DESCRIPTION:

TRIMS:

Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 8-1/8” aperture.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

8”

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HVJ8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

8101-Reflector

8114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8102-Baffle Reflector

8115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

8103-Reflector/Fresnel Glass Lens

8116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

8104-Reflector/Prismatic Glass Lens

8117-Baffle/Prismatic Plastic Lens

w

frost

8105-Baffle/Fresnel Glass Lens

8118-Reflector/Tempered Clear Plastic

mb

8106-Baffle/Prismatic Glass Lens

8119-Baffle/Tempered Clear Plastic

fuse

8107-Wall Wash Reflector

8109-Deco Glass Ring

rif

8108-Crossblade Reflector

8110-Double Ring

8112-Baffle/Frosted Glass Lens

8111-Triple Ring

Other Options

8113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HVJ8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH 46

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” vertical fluorescent trims 8108-CL

8101-CL

8102-WH-CL

8107-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

8103-CL

8114-CL

8104-CL

8115-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 9-1/8”

8” 8112-WH

8105-P

8106-WH

8113-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8116-CL

8117-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

8118-WT

8119-WH

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8101-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

47


8” vertical fluorescent trims 8121-CL

8122-CL

8123-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

8124-CL geo deco ring glass

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8127-CL

8125-CL

8126-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

8” 8110-CL

8111-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

8109-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8101-WH-INTG 48

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” vertical fluorescent trims

8”

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

49


photometric data

8”

50

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


photometric data hv8pl-1x26-e-8101cl / hvr8pl-1x26-e-8101cl / hvj8pl1x26-e-6101cl- / bhvr8pl-1x26-e-8101cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 1800

Zonal Lumens Summary Zone Lumens 0-300 590.99 0-400 853.46 0 0-60 1229.7 0 0-90 1277.79 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1277.79

test no.: lli 0205-10e

total luminaire efficiency: 71%

%Lamp 32.8 47.4 68.3 71 0 0 0 0 71

%Fixt 46.3 66.8 96.2 100 0 0 0 0 100

spacing criteria: 1.06

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

13626 4086 491 381 654

0-10 . . . . . . . . . . 80.13 10-20 . . . . . . . . . 246.11 20-30 . . . . . . . . . 264.76 30-40 . . . . . . . . . 262.47 40-50 . . . . . . . . . 273.77 50-60 . . . . . . . . . 102.48 60-70 . . . . . . . . . 39.67 70-80 . . . . . . . . . 5.16 80-90 . . . . . . . . . 3.26

Total Luminaire Efficiency = 71%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

63.0 28.0 15.8 10.1 7.0

8.3’ 12.4’ 16.6’ 20.7’ 24.9’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 92 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance

79 73 66 61 56 51 47 44 40 38 35

76 70 64 59 54 50 46 43 40 37 35

72 68 62 57 53 49 45 42 39 36 34

71 64 57 51 46 42 38 34 31 29 27

79 71 64 57 52 47 43 39 36 33 31

79 70 61 54 49 44 39 36 33 30 28

76 69 62 56 51 46 42 39 36 33 31

76 68 60 54 48 43 39 36 33 30 28

72 67 60 55 50 45 42 38 35 33 30

72 66 59 53 47 43 39 35 33 30 28

hv8pl-1x32-e-8101cl / hvr8pl-1x32-e-8101cl / hvj8pl1x32-e-8101cl- / bhvr8pl-1x32-e-8101cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 2400

Zone Lumens 0-300 788.39 0-400 1138.52 0 0-60 1640.43 0 0-90 1704.58 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1704.58

test no.: lli 0205-10aa

total luminaire efficiency: 71%

Zonal Lumens Summary %Lamp 32.8 47.4 68.4 71 0 0 0 0 71

%Fixt 46.3 66.8 96.2 100 0 0 0 0 100

spacing criteria: 1.06

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

18177 5451 655 508 871

0-10 . . . . . . . . . . 106.89 10-20 . . . . . . . . . 328.3 20-30 . . . . . . . . . 353.19 30-40 . . . . . . . . . 350.13 40-50 . . . . . . . . . 365.2 50-60 . . . . . . . . . 136.7 60-70 . . . . . . . . . 52.92 70-80 . . . . . . . . . 6.89 80-90 . . . . . . . . . 4.35

Total Luminaire Efficiency = 71%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

84.0 37.3 21.0 13.4 9.3

8.3’ 12.4’ 16.6’ 20.7’ 24.9’

Distance Footcandles to Plane Beam Initial Nadir Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C.

R oom C av i t y R a t io

Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance

79 73 66 61 56 51 47 44 40 38 35

76 70 64 59 54 50 46 43 40 37 35

72 68 62 57 53 49 45 42 39 36 34

71 64 57 51 46 42 38 34 31 29 27

79 71 64 57 52 47 43 39 36 33 31

79 70 61 54 49 44 39 36 33 30 28

76 69 62 56 51 46 42 39 36 33 31

76 68 60 54 48 43 39 36 33 30 28

72 67 60 55 50 45 42 38 35 33 30

72 66 59 53 47 43 39 35 33 30 28

hv8pl-1x42-e-8101cl / hvr8pl-1x42-e-8101cl / hvj8pl1x42-e-8101cl- / bhvr8pl-1x42-e-8101cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 3200

Zone Lumens 0-300 1050.79 0-400 1517.46 0 0-60 2186.42 0 0-90 2271.92 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2271.92

%Lamp 32.8 47.4 68.3 71 0 0 0 0 71

%Fixt 46.3 66.8 96.2 100 0 0 0 0 100

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Average 0-900

Zone Lumens

450 550 650 750 850

24227 7266 873 676 1162

0-10 . . . . . . . . . . 142.47 10-20 . . . . . . . . . 437.57 20-30 . . . . . . . . . 470.74 30-40 . . . . . . . . . 466.67 40-50 . . . . . . . . . 486.75 50-60 . . . . . . . . . 182.2 60-70 . . . . . . . . . 70.53 70-80 . . . . . . . . . 9.18 80-90 . . . . . . . . . 5.8

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 92 Degrees 8.3’ 12.4’ 16.6’ 20.7’ 24.9’

Distance to Plane

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

RC RW

R oom Ca vi t y Ra t i o

112.0 49.8 28.0 17.9 12.4

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance

79 73 66 61 56 51 47 44 40 38 35

76 70 64 59 54 50 46 43 40 37 35

72 68 62 57 53 49 45 42 39 36 34

71 64 57 51 46 42 38 34 31 29 27

79 71 64 57 52 47 43 39 36 33 31

79 70 61 54 49 44 39 36 33 30 28

76 69 62 56 51 46 42 39 36 33 31

76 68 60 54 48 43 39 36 33 30 28

8”

spacing criteria: 1.06

Total Luminaire Efficiency = 71%

4’ 6’ 8’ 10’ 12’

Candela Tabulation 0 0 . . . . . . . . . 1344.47 1 . . . . . . . . . 1353.75 3 . . . . . . . . . 1386.3 5 . . . . . . . . . 1395.38 7 . . . . . . . . . 1388.28 9 . . . . . . . . . 1359.35 11 . . . . . . . . 1301.18 13 . . . . . . . . 1217.79 15 . . . . . . . . 1152.38 17 . . . . . . . . 1089.98 19.5 . . . . . . 996.48 22.5 . . . . . . 870.73 25.5 . . . . . . 777.58 29 . . . . . . . . 734.69 33 . . . . . . . . 696.71 37.5 . . . . . . 627.14 42.5 . . . . . . 518.76 47.5 . . . . . . 324.04 55 . . . . . . . . 102.51 65 . . . . . . . . 9.07 75 . . . . . . . . 4.31 85 . . . . . . . . 2.49 90 . . . . . . . . 0

test no.: lli 0205-10bb

total luminaire efficiency: 71%

Zonal Lumens Summary

Candela Tabulation 0 0 . . . . . . . . . 1007.84 1 . . . . . . . . . 1014.8 3 . . . . . . . . . 1039.2 5 . . . . . . . . . 1046.01 7 . . . . . . . . . 1040.69 9 . . . . . . . . . 1019 11 . . . . . . . . 975.4 13 . . . . . . . . 912.89 15 . . . . . . . . 863.85 17 . . . . . . . . 817.08 19.5 . . . . . . 746.99 22.5 . . . . . . 652.72 25.5 . . . . . . 582.89 29 . . . . . . . . 550.74 33 . . . . . . . . 522.27 37.5 . . . . . . 470.12 42.5 . . . . . . 388.88 47.5 . . . . . . 242.91 55 . . . . . . . . 76.84 65 . . . . . . . . 6.8 75 . . . . . . . . 3.23 85 . . . . . . . . 1.87 90 . . . . . . . . 0

72 67 60 55 50 45 42 38 35 33 30

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

72 66 59 53 47 43 39 35 33 30 28

Candela Tabulation 0 0 . . . . . . . . . 1791.95 1 . . . . . . . . . 1804.32 3 . . . . . . . . . 1847.71 5 . . . . . . . . . 1859.81 7 . . . . . . . . . 1850.35 9 . . . . . . . . . 1811.79 11 . . . . . . . . 1734.25 13 . . . . . . . . 1623.11 15 . . . . . . . . 1535.93 17 . . . . . . . . 1452.76 19.5 . . . . . . 1328.14 22.5 . . . . . . 1160.54 25.5 . . . . . . 1036.38 29 . . . . . . . . 979.22 33 . . . . . . . . 928.6 37.5 . . . . . . 835.88 42.5 . . . . . . 691.42 47.5 . . . . . . 431.89 55 . . . . . . . . 136.63 65 . . . . . . . . 12.09 75 . . . . . . . . 5.74 85 . . . . . . . . 3.32 90 . . . . . . . . 0

51


hV10pl fluorescent series 10” vertical fluorescent downlighting

A. Height = 15-1/4” B. Trim Aperture = 9-3/4” c. Cut-out = 10-1/2” d. Trim Outside Dia. = 10-3/4” e. Width = 17-1/2” f. Length = 16-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

10”

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HV10PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

1101-Reflector

wh

cl

blue

emg 1300

1102-Baffle Reflector

p

shz

red

intg 750

1103-Reflector/Fresnel Glass Lens

wt

green

intg 1300

1104-Reflector/Prismatic Glass Lens

w

frost

emg-d-750

1105-Baffle/Fresnel Glass Lens

mb

intg-d-750

1106-Baffle/Prismatic Glass Lens

ice-1300

1112-Baffle/Frosted Glass Lens

fuse

1114-Reflector/Frosted Glass Lens

BAFFLE REFLECTOR RING WH White CL Clear WH Self-Flange White P Black WT Wheat Standard on all trims MB Black SCH** Self-Flange Chrome W White ** Only available on 1101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only

rif

1115-Reflector/Tempered Glass Lens

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Other Options

1113-Baffle/Tempered Glass Lens

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV10PL-1X18-FDB-T418-120-EMG 750-1101-CL-WH 52

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


10” vertical fluorescent series

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 1101-WH-INTG

1101-CL

1102-WH-CL

REFLECTOR

baffle w/ REFLECTOR

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

RING finish: Wh, SCH, shz

reflector finish: CL

1103-CL

1104-CL

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ prismatic glass lens

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

1105-P

1106-WH

baffle w/ fresnel glass lens

baffle w/ prismatic glass lens

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

1112-WH

1113-WH

baffle w/ frosted glass lens

baffle w/ tempered clear glass

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

1114-CL

1115-WT

REFLECTOR w/ frosted glass lens

reflector w/ tempered clear glass

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

10”

53


hs6pl fluorescent series 6” horizontal fluorescent shallow downlighting

new A. Height = 4” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/8” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2”

4”

( SHALLOW )

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HS6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

6”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

6701-Reflector

6714-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6702-Baffle Reflector

6715-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6703-Reflector/Fresnel Glass Lens

6716-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6704-Reflector/Prismatic Glass Lens

6717-Baffle/Prismatic Plastic Lens

w

frost

6705-Baffle/Fresnel Glass Lens

6718-Reflector/Tempered Clear Plastic

mb

6706-Baffle/Prismatic Glass Lens

6719-Baffle/Tempered Clear Plastic

fuse

6707-Wall Wash Reflector

6709-Deco Glass Ring

rif

6708-Crossblade Reflector

6710-Double Ring

6712-Baffle/Frosted Glass Lens

6711-Triple Ring

Other Options

6713-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6709, 6710 MB Black SCH** Self-Flange Chrome and 6711. W White ** Only available on 6701 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HS6PL-1X18-FDB-T418-120-EMG 750-6701-CL-WH 54

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” horizontal fluorescent shallow trims 6708-CL

6701-CL

6702-WH-CL

6707-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

6703-CL

6714-CL

6704-CL

6715-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 7-3/8”

6” 6712-WH

6705-P

6706-WH

6713-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6716-CL

6717-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

6718-WT

6719-WH

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

55


6” horizontal fluorescent shallow trims

6”

56

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” horizontal fluorescent shallow trims 6721-CL

6722-CL

6723-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

6724-CL geo deco ring glass

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6727-CL

6725-CL

6726-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

6” 6710-CL

6711-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

6709-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

57


hh6pl fluorescent series 6” horizontal fluorescent downlighting

A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HH6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

6”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6501-Reflector

6514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6502-Baffle Reflector

6515-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

6503-Reflector/Fresnel Glass Lens

6516-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

6504-Reflector/Prismatic Glass Lens

6517-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

6505-Baffle/Fresnel Glass Lens

6518-Reflector/Tempered Clear Plastic

mb

intg-d-750

6506-Baffle/Prismatic Glass Lens

6519-Baffle/Tempered Clear Plastic

ice-1300

6507-Wall Wash Reflector

6509-Deco Glass Ring

Other Options

6508-Crossblade Reflector

6510-Double Ring

fuse

6512-Baffle/Frosted Glass Lens

6511-Triple Ring

rif

6513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HH6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 58

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hh6plic-at fluorescent series 6” horizontal fluorescent ic downlighting

A. Height = 7-3/4” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 10” f. Length = 12-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HH6PLIC-AT - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

6”

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6501-Reflector

6514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6502-Baffle Reflector

6515-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6503-Reflector/Fresnel Glass Lens

6516-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6504-Reflector/Prismatic Glass Lens

6517-Baffle/Prismatic Plastic Lens

w

frost

6505-Baffle/Fresnel Glass Lens

6518-Reflector/Tempered Clear Plastic

mb

6506-Baffle/Prismatic Glass Lens

6519-Baffle/Tempered Clear Plastic

fuse

6507-Wall Wash Reflector

6509-Deco Glass Ring

rif

6508-Crossblade Reflector

6510-Double Ring

6512-Baffle/Frosted Glass Lens

6511-Triple Ring

Other Options

6513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HH6PLIC-AT-1X18-FDB-T418-120-EMG 750-6501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

59


bhhr6pl fluorescent series 6” horizontal fluorescent downlighting

A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

BHHR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

6”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6501-Reflector

6514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6502-Baffle Reflector

6515-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

6503-Reflector/Fresnel Glass Lens

6516-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

6504-Reflector/Prismatic Glass Lens

6517-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

6505-Baffle/Fresnel Glass Lens

6518-Reflector/Tempered Clear Plastic

mb

intg-d-750

6506-Baffle/Prismatic Glass Lens

6519-Baffle/Tempered Clear Plastic

ice-1300

6507-Wall Wash Reflector

6509-Deco Glass Ring

Other Options

6508-Crossblade Reflector

6510-Double Ring

fuse

6512-Baffle/Frosted Glass Lens

6511-Triple Ring

rif

6513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: BHHR6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 60

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hhr6pl fluorescent series 6” horizontal fluorescent remodel downlighting

A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 7-1/2” f. Length = 12-1/2” g. Flange = 1-1/2”

DESCRIPTION:

TRIMS:

Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HHR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

6”

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

1X26-HL3-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

6501-Reflector

6514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6502-Baffle Reflector

6515-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6503-Reflector/Fresnel Glass Lens

6516-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6504-Reflector/Prismatic Glass Lens

6517-Baffle/Prismatic Plastic Lens

w

frost

6505-Baffle/Fresnel Glass Lens

6518-Reflector/Tempered Clear Plastic

mb

6506-Baffle/Prismatic Glass Lens

6519-Baffle/Tempered Clear Plastic

fuse

6507-Wall Wash Reflector

6509-Deco Glass Ring

rif

6508-Crossblade Reflector

6510-Double Ring

6512-Baffle/Frosted Glass Lens

6511-Triple Ring

Other Options

6513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HHR6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

61


hhj6pl fluorescent series 6” horizontal fluorescent retrofit downlighting

A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)

B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8”

universal n installatio

(frame not included)

DESCRIPTION:

TRIMS:

Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 6-3/4” aperture.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HHJ6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

6”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

6501-Reflector

6514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

6502-Baffle Reflector

6515-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

6503-Reflector/Fresnel Glass Lens

6516-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

6504-Reflector/Prismatic Glass Lens

6517-Baffle/Prismatic Plastic Lens

w

frost

6505-Baffle/Fresnel Glass Lens

6518-Reflector/Tempered Clear Plastic

mb

6506-Baffle/Prismatic Glass Lens

6519-Baffle/Tempered Clear Plastic

fuse

6507-Wall Wash Reflector

6509-Deco Glass Ring

rif

6508-Crossblade Reflector

6510-Double Ring

6512-Baffle/Frosted Glass Lens

6511-Triple Ring

Other Options

6513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HHJ6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 62

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” horizontal fluorescent trims 6508-CL

6501-CL

6502-WH-CL

6507-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

6503-CL

6514-CL

6504-CL

6515-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 7-3/8”

6” 6512-WH

6505-P

6506-WH

6513-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6516-CL

6517-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

6518-WT

6519-WH

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

63


6” horizontal fluorescent trims 6521-CL

6522-CL

6523-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

6524-CL geo deco ring glass

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

6527-CL

6525-CL

6526-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

6” 6510-CL

6511-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 7-3/8”

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 7-3/8”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

6509-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG 64

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” horizontal fluorescent trims

6”

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

65


photometric data hh6pl-1x26-e-6501-cl / bhhr6pl-1x26-e-6501-cl / hhr6pl-1x26-e-6501-cl / hhj6pl-1x26-e-6501-cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 1800

Zonal Lumens Summary Zone Lumens 0-300 433.56 0-400 681.63 0 0-60 1042.61 0 0-90 1074.19 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1074.19

test no.: lli 0204-14f

total luminaire efficiency: 59.7%

%Lamp 24.1 37.9 57.9 59.7 0 0 0 0 59.7

Luminance Data (cd/sq.m)

%Fixt 40.4 63.5 97.1 100 0 0 0 0 100

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

45 550 650 750 850

23711 5323 623 610 1208

26429 3763 498 610 1208

25349 4130 623 610 1208

0

spacing criteria: 1.34

Zone Lumens 0-10 . . . . . . . . . . 42.39 10-20 . . . . . . . . . 154.75 20-30 . . . . . . . . . 236.41 30-40 . . . . . . . . . 248.07 40-50 . . . . . . . . . 262.61 50-60 . . . . . . . . . 98.37 60-70 . . . . . . . . . 24.22 70-80 . . . . . . . . . 4.08 80-90 . . . . . . . . . 3.28

Total Luminaire Efficiency = 59.7%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF

Distance to Plane

33.6 14.9 8.4 5.4 3.7

9.5’ 14.3’ 19.1’ 23.8’ 28.6’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

RC RW

80% 70% 50% 30% 10%

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

0 1 2 3 4 5

71 67 62 58 54 50

69 65 61 56 52 49

69 60 52 46 40 36

66 61 55 50 46 42

66 59 53 47 42 38

66 58 51 45 40 35

63 59 54 49 44 41

63 57 52 46 41 37

63 56 50 44 39 35

61 57 52 47 43 40

61 56 50 45 41 37

61 55 49 43 39 39

60 54 48 42 38 33

45 39 35 32 42 36 32 28 40 33 29 26 37 30 26 23 35 24 21 RW - 28 Wall Reflectance

38 35 32 30 28

34 31 28 26 24

31 28 26 23 21

37 34 32 29 27

34 31 28 26 24

31 28 25 23 21

36 33 31 29 27

33 30 28 25 23

31 28 25 23 21

30 27 24 22 20

71 65 58 53 48 43

71 63 55 49 44 39

71 61 53 46 40 36

6 46 40 35 32 7 43 36 32 29 8 40 33 29 26 9 38 31 26 23 10 - Ceiling 36 Cavity 28 Reflectance 24 21 RC

69 69 63 62 57 55 52 48 47 43 43 39

Candela Tabulation 0 0 . . . . . 537 . . . . . . 1 . . . . . 544 . . . . . . 3 . . . . . 558 . . . . . . 5 . . . . . 569 . . . . . . 7 . . . . . 580 . . . . . . 9 . . . . . 584 . . . . . . 11 . . . . 585 . . . . . . 13 . . . . 589 . . . . . . 15 . . . . 599 . . . . . . 17 . . . . 611 . . . . . . 19.5 . . . 626 . . . . . . 22.5 . . . 619 . . . . . . 25.5 . . . 632 . . . . . . 29 . . . . 624 . . . . . . 33 . . . . 595 . . . . . . 37.5 . . . 523 . . . . . . 42.5 . . . 378 . . . . . . 47.5 . . . 259 . . . . . . 55 . . . . 58 . . . . . . . 65 . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .

hh6pl-1x32-e-6501-cl / bhhr6pl-1x32-e-6501-cl / hhr6pl-1x32-e-6501-cl / hhj6pl-1x32-e-6501-cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 2400

Zone Lumens 0-300 578.5 0-400 909.41 0 0-60 1391.1 0 0-90 1433.09 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1433.09

6”

%Lamp 24.1 37.9 58 59.7 0 0 0 0 59.7

Luminance Data (cd/sq.m)

%Fixt 40.4 63.5 97.1 100 0 0 0 0 100

spacing criteria: 1.34

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

31640 7159 872 814 1812

35251 5048 747 610 1208

33762 5507 747 814 1812

Zone Lumens 0-10 . . . . . . . . . . 56.57 10-20 . . . . . . . . . 206.51 20-30 . . . . . . . . . 315.43 30-40 . . . . . . . . . 330.91 40-50 . . . . . . . . . 350.36 50-60 . . . . . . . . . 131.34 60-70 . . . . . . . . . 32.37 70-80 . . . . . . . . . 5.31 80-90 . . . . . . . . . 4.31

Total Luminaire Efficiency = 59.7%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF

Distance to Plane

44.8 19.9 11.2 7.2 5.0

9.5’ 14.3’ 19.1’ 23.8’ 28.6’

Initial Nadir Footcandles

Beam Spread

R oom C av i t y R a t io

Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

RC RW

80% 70% 50% 30% 10%

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

0 1 2 3 4 5

71 67 62 58 54 50

69 65 61 57 53 49

69 60 52 46 40 36

66 61 55 50 46 42

66 60 53 47 42 38

66 58 51 45 40 35

64 59 54 49 44 41

64 58 52 46 41 37

64 57 50 44 39 35

61 57 52 47 43 40

61 56 50 45 41 37

61 55 49 43 39 39

60 54 48 42 38 33

45 39 35 32 42 36 32 28 40 33 29 26 37 30 26 23 35 24 21 RW - 28 Wall Reflectance

38 35 32 30 28

34 31 28 26 24

31 28 26 23 21

37 34 32 29 27

34 31 28 26 24

31 28 25 23 21

36 33 31 29 27

33 30 28 25 23

31 28 25 23 21

30 27 24 22 20

71 65 58 53 48 44

71 63 55 49 44 39

71 61 53 46 40 36

6 46 40 35 32 7 43 36 32 29 8 41 33 29 26 9 38 31 26 23 10 - Ceiling 36 Cavity 28 Reflectance 24 21 RC

69 69 63 62 57 55 52 48 47 43 43 39

Candela Tabulation 0 45 0 . . . . . 716 . . . . . . 716 . . . . . . 1 . . . . . 726 . . . . . . 721 . . . . . . 3 . . . . . 744 . . . . . . 742 . . . . . . 5 . . . . . 759 . . . . . . 756 . . . . . . 7 . . . . . 774 . . . . . . 771 . . . . . . 9 . . . . . 779 . . . . . . 780 . . . . . . 11 . . . . 781 . . . . . . 781 . . . . . . 13 . . . . 785 . . . . . . 790 . . . . . . 15 . . . . 799 . . . . . . 814 . . . . . . 17 . . . . 815 . . . . . . 847 . . . . . . 19.5 . . . 836 . . . . . . 872 . . . . . . 22.5 . . . 826 . . . . . . 895 . . . . . . 25.5 . . . 843 . . . . . . 883 . . . . . . 29 . . . . 832 . . . . . . 811 . . . . . . 33 . . . . 794 . . . . . . 740 . . . . . . 37.5 . . . 698 . . . . . . 690 . . . . . . 42.5 . . . 505 . . . . . . 564 . . . . . . 47.5 . . . 345 . . . . . . 383 . . . . . . 55 . . . . 78 . . . . . . . 55 . . . . . . . 65 . . . . 7 . . . . . . . . 6 . . . . . . . . 75 . . . . 4 . . . . . . . . 4 . . . . . . . . 85 . . . . 3 . . . . . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .

hh6pl-1x42-e-6501-cl / bhhr6pl-1x42-e-6501-cl / hhr6pl-1x42-e-6501-cl / hhj6pl-1x42-e-6501-cl lamp: sylvania cf42dt/e/in/835 Candle Power Distribution (Candelas)

lumens: 3200

Zone Lumens 0-300 571.1 0-400 904.41 0-600 1392.7 0-900 1434.87 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1434.87

%Lamp 17.8 28.3 43.5 44.8 0 0 0 0 44.8

%Fixt 39.8 63 97.1 100 0 0 0 0 100

Luminance Data (cd/sq.m)

spacing criteria: 1.36 Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

34246 7159 623 610 1208

34730 6608 623 610 1208

33725 5966 747 610 1208

Zone Lumens 0-10 . . . . . . . . . . 54.55 10-20 . . . . . . . . . 204.11 20-30 . . . . . . . . . 312.43 30-40 . . . . . . . . . 333.31 40-50 . . . . . . . . . 355.83 50-60 . . . . . . . . . 132.46 60-70 . . . . . . . . . 34.23 70-80 . . . . . . . . . 4.7 80-90 . . . . . . . . . 3.24

Total Luminaire Efficiency = 44.8%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

43.3 19.3 10.8 6.9 4.8

9.9’ 14.8’ 19.8’ 24.7’ 29.6’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

66

R oom Ca vi t y Ra t i o

Beam Angle: 102 Degrees 4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 71 71 71 71 1 67 65 63 62 2 63 59 56 53 3 58 53 49 46 4 54 48 44 41 5 50 44 39 36 6 47 40 36 32 7 44 37 32 29 8 41 34 29 26 9 38 31 27 24 10 36 29 25 22 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

70 70 70 70 66 64 62 61 61 58 55 53 57 52 49 46 53 48 44 41 49 43 39 36 46 40 35 32 43 36 32 29 40 33 29 26 38 31 27 24 35 29 25 22 RW - Wall Reflectance

67 61 56 51 46 42 39 35 33 30 28

64 59 54 49 45 41 38 35 32 30 28

61 57 52 48 44 40 37 34 31 29 27

60 54 48 43 38 34 34 27 25 23 21

67 60 53 48 43 38 35 32 29 26 24

67 59 51 45 40 36 32 29 26 24 22

64 58 52 47 42 38 34 31 28 26 24

64 57 50 44 40 35 32 29 26 24 22

90 716 718 737 767 749 750 741 741 747 766 782 773 763 725 650 654 510 397 60 6 4 3 0

test no.: lli 0205-10g

total luminaire efficiency: 44.8%

Zonal Lumens Summary

90 537 538 552 558 561 562 555 555 560 574 586 580 572 543 487 490 383 298 45 5 3 2 0

test no.: lli 0204-14b

total luminaire efficiency: 59.7%

Zonal Lumens Summary

45 537 . . . . . 541 . . . . . 556 . . . . . 567 . . . . . 578 . . . . . 584 . . . . . 585 . . . . . 592 . . . . . 610 . . . . . 635 . . . . . 653 . . . . . 671 . . . . . 662 . . . . . 608 . . . . . 555 . . . . . 517 . . . . . 423 . . . . . 287 . . . . . 41 . . . . . . 4 . . . . . . . 3 . . . . . . . 2 . . . . . . . 0 . . . . . . .

61 56 51 46 41 37 34 31 28 26 24

61 55 49 44 39 35 35 28 26 23 22

Candela Tabulation 0 45 0 . . . . . 693 . . . . . . 693 . . . . . . 1 . . . . . 699 . . . . . . 698 . . . . . . 3 . . . . . 713 . . . . . . 710 . . . . . . 5 . . . . . 727 . . . . . . 723 . . . . . . 7 . . . . . 744 . . . . . . 738 . . . . . . 9 . . . . . 753 . . . . . . 751 . . . . . . 11 . . . . 761 . . . . . . 758 . . . . . . 13 . . . . 770 . . . . . . 773 . . . . . . 15 . . . . 785 . . . . . . 799 . . . . . . 17 . . . . 802 . . . . . . 825 . . . . . . 19.5 . . . 815 . . . . . . 851 . . . . . . 22.5 . . . 810 . . . . . . 886 . . . . . . 25.5 . . . 821 . . . . . . 844 . . . . . . 29 . . . . 806 . . . . . . 795 . . . . . . 33 . . . . 782 . . . . . . 750 . . . . . . 37.5 . . . 695 . . . . . . 692 . . . . . . 42.5 . . . 553 . . . . . . 551 . . . . . . 47.5 . . . 367 . . . . . . 382 . . . . . . 55 . . . . 78 . . . . . . . 72 . . . . . . . 65 . . . . 5 . . . . . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

90 693 693 703 713 718 720 717 714 728 751 771 765 744 709 649 664 518 388 65 6 3 2 0


photometric data hh6pl-2x13-e-6501-cl / bhhr6pl-2x13-e-6501-cl / hh6plic-2x13-e-6501-cl / hhr6pl-2x13-e-6501-cl / hhj6pl-2x13-e-6501-cl lamp: 2 philips pl-c 13w/27/4p lumens: 1800 (2 lamps) total luminaire efficiency: 42.1% Candle Power Distribution (Candelas)

Zonal Lumens Summary Zone Lumens 0-300 332.16 0-400 504.8 0 0-60 738.38 0 0-90 757.31 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 757.31

%Lamp 18.5 28 41 42.1 0 0 0 0 42.1

%Fixt 43.9 66.7 97.5 100 0 0 0 0 100

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

45 550 650 750 850

12768 918 374 407 604

15671 2478 374 407 604

16453 3120 374 407 604

0

Zone Lumens 0-10 . . . . . . . . . . 32.04 10-20 . . . . . . . . . 125.02 20-30 . . . . . . . . . 175.1 30-40 . . . . . . . . . 172.64 40-50 . . . . . . . . . 171.53 50-60 . . . . . . . . . 62.05 60-70 . . . . . . . . . 14.46 70-80 . . . . . . . . . 2.57 80-90 . . . . . . . . . 1.89

Total Luminaire Efficiency = 42.1%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

25.1 11.2 6.3 4.0 2.8

8.9’ 13.3’ 17.8’ 22.2’ 26.7’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 50 50 50 50 1 47 46 44 43 2 44 41 39 38 3 41 38 35 33 4 38 34 31 29 5 36 31 28 26 6 33 29 25 23 7 31 26 23 21 8 29 24 21 19 9 27 22 19 17 10 26 21 18 16 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

49 49 49 49 46 45 44 43 43 41 39 37 40 37 35 33 37 34 31 29 35 31 28 26 33 28 25 23 30 26 23 21 28 24 21 19 27 22 19 17 25 21 18 16 RW - Wall Reflectance

47 43 39 36 33 30 27 25 23 22 20

45 41 38 35 32 29 27 25 23 21 20

43 40 37 34 31 28 26 24 22 21 19

42 38 34 30 27 24 22 20 18 16 15

47 42 38 34 30 27 25 23 21 19 18

47 41 36 32 28 25 23 21 19 17 16

45 41 37 33 30 27 24 22 20 19 17

45 40 35 32 28 25 23 21 19 17 16

43 39 36 32 29 27 24 22 20 19 17

43 39 35 31 28 25 23 20 19 17 16

test no.: lli 0205-10k spacing criteria: 1.28 Candela Tabulation 0 45 0 . . . . . 402 . . . . . . 402 . . . . . . 1 . . . . . 404 . . . . . . 403 . . . . . . 3 . . . . . 405 . . . . . . 407 . . . . . . 5 . . . . . 398 . . . . . . 410 . . . . . . 7 . . . . . 401 . . . . . . 431 . . . . . . 9 . . . . . 390 . . . . . . 437 . . . . . . 11 . . . . 389 . . . . . . 453 . . . . . . 13 . . . . 393 . . . . . . 467 . . . . . . 15 . . . . 391 . . . . . . 471 . . . . . . 17 . . . . 388 . . . . . . 468 . . . . . . 19.5 . . . 382 . . . . . . 466 . . . . . . 22.5 . . . 363 . . . . . . 458 . . . . . . 25.5 . . . 354 . . . . . . 434 . . . . . . 29 . . . . 347 . . . . . . 401 . . . . . . 33 . . . . 343 . . . . . . 356 . . . . . . 37.5 . . . 289 . . . . . . 327 . . . . . . 42.5 . . . 197 . . . . . . 242 . . . . . . 47.5 . . . 146 . . . . . . 179 . . . . . . 55 . . . . 10 . . . . . . . 27 . . . . . . . 65 . . . . 3 . . . . . . . . 3 . . . . . . . . 75 . . . . 2 . . . . . . . . 2 . . . . . . . . 85 . . . . 1 . . . . . . . . 1 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .

hh6pl-2x18-e-6501-cl / bhhr6pl-2x18-e-6501-cl / hh6plic-2x18-e-6501-cl / hhr6pl-2x18-e-6501-cl / hhj6pl-2x18-e-6501-cl lamp: 2 philips pl-c 18w/27/4p lumens: 2500 (2 lamps) total luminaire efficiency: 42% Candle Power Distribution (Candelas)

Zonal Lumens Summary Zone Lumens 0-300 461.29 0-400 701.12 0 0-60 1025.7 0 0-90 1051.02 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1051.02

%Lamp 18.5 28 41 42 0 0 0 0 42

%Fixt 43.9 66.7 97.6 100 0 0 0 0 100

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

17756 1193 498 407 604

21776 3488 498 407 604

22855 4314 498 407 604

Zone Lumens 0-10 . . . . . . . . . . 44.5 10-20 . . . . . . . . . 173.65 20-30 . . . . . . . . . 243.15 30-40 . . . . . . . . . 239.83 40-50 . . . . . . . . . 238.33 50-60 . . . . . . . . . 86.25 60-70 . . . . . . . . . 20.19 70-80 . . . . . . . . . 3.25 80-90 . . . . . . . . . 1.89

Total Luminaire Efficiency = 42%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

34.9 15.5 8.7 5.6 3.9

8.9’ 13.3’ 17.8’ 11.1’ 26.7’

Initial Nadir Footcandles

Beam Spread

R oom C av i t y R a t io

Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 50 50 50 50 1 47 46 44 43 2 44 41 39 38 3 41 38 35 33 4 38 34 31 29 5 36 31 28 26 6 33 29 25 23 7 31 26 23 21 8 29 24 21 19 9 27 22 19 17 10 26 21 18 16 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

49 49 49 49 46 45 44 43 43 41 39 37 40 37 35 33 37 34 31 29 35 31 28 26 33 28 25 23 30 26 23 21 28 24 21 19 27 22 19 17 25 21 18 16 RW - Wall Reflectance

47 43 39 36 33 30 27 25 23 22 20

45 41 38 35 32 29 27 25 23 21 20

43 40 37 34 31 28 26 24 22 21 19

42 38 34 30 27 24 22 20 18 16 15

47 42 38 34 30 27 25 23 21 19 18

47 41 36 32 28 25 23 21 19 17 16

45 41 37 33 30 27 24 22 20 19 17

45 40 35 32 28 25 23 21 19 17 16

43 39 36 32 29 27 24 22 20 19 17

43 39 35 31 28 25 23 20 19 17 16

test no.: lli 0205-10u spacing criteria: 1.28 Candela Tabulation 0 0 . . . . . 558 . . . . . . 1 . . . . . 561 . . . . . . 3 . . . . . 563 . . . . . . 5 . . . . . 553 . . . . . . 7 . . . . . 557 . . . . . . 9 . . . . . 541 . . . . . . 11 . . . . 541 . . . . . . 13 . . . . 546 . . . . . . 15 . . . . 543 . . . . . . 17 . . . . 539 . . . . . . 19.5 . . . 530 . . . . . . 22.5 . . . 504 . . . . . . 25.5 . . . 492 . . . . . . 29 . . . . 481 . . . . . . 33 . . . . 476 . . . . . . 37.5 . . . 402 . . . . . . 42.5 . . . 274 . . . . . . 47.5 . . . 203 . . . . . . 55 . . . . 13 . . . . . . . 65 . . . . 4 . . . . . . . . 75 . . . . 2 . . . . . . . . 85 . . . . 1 . . . . . . . . 90 . . . . 0 . . . . . . . .

hh6pl-2x26-e-6501-cl / bhhr6pl-2x26-e-6501-cl / hh6plic-2x26-e-6501-cl / hhr6pl-2x26-e-6501-cl / hhj6pl-2x26-e-6501-cl lamp: 2 sylvania cf26dt/e/in/841 lumens: 3600 (2 lamps) total luminaire efficiency: 60% Candle Power Distribution (Candelas)

Zonal Lumens Summary Zone Lumens 0-300 896.48 0-400 1381.41 0-600 2097.34 0-900 2161.41 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 2161.41

%Lamp 24.9 38.4 58.3 60 0 0 0 0 60

%Fixt 41.5 63.9 97 100 0 0 0 0 100

Luminance Data (cd/sq.m)

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

39792 6149 1121 1017 1812

45636 8077 1246 1220 1812

51331 9912 1121 1017 2416

Zone Lumens 0-10 . . . . . . . . . . 87.26 10-20 . . . . . . . . . 339.05 20-30 . . . . . . . . . 470.17 30-40 . . . . . . . . . 484.93 40-50 . . . . . . . . . 520.01 50-60 . . . . . . . . . 195.92 60-70 . . . . . . . . . 50.57 70-80 . . . . . . . . . 7.62 80-90 . . . . . . . . . 5.88

Total Luminaire Efficiency = 60%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

65.9 29.3 16.5 10.5 7.3

9.2’ 13.8’ 18.4’ 23.0’ 27.6’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

R oom Ca vi t y Ra t i o

Beam Angle: 98 Degrees 4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 71 71 71 71 1 67 65 63 62 2 63 59 56 53 3 58 53 49 46 4 54 48 44 41 5 50 44 39 36 6 47 40 36 32 7 44 37 32 29 8 41 34 29 26 9 38 31 27 24 10 36 29 25 22 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

70 70 70 70 66 64 62 61 61 58 55 53 57 52 49 46 53 48 44 41 49 43 39 36 46 40 35 32 43 36 32 29 40 33 29 26 38 31 27 24 35 29 25 22 RW - Wall Reflectance

67 61 56 51 46 42 39 35 33 30 28

64 59 54 49 45 41 38 35 32 30 28

61 57 52 48 44 40 37 34 31 29 27

60 54 48 43 38 34 34 27 25 23 21

67 60 53 48 43 38 35 32 29 26 24

67 59 51 45 40 36 32 29 26 24 22

64 58 52 47 42 38 34 31 28 26 24

64 57 50 44 40 35 32 29 26 24 22

61 56 51 46 41 37 34 31 28 26 24

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

61 55 49 44 39 35 35 28 26 23 22

90 402 402 407 419 438 452 463 487 505 500 502 483 451 405 360 348 265 177 34 3 2 1 0

45 558 . . . . . 559 . . . . . 656 . . . . . 567 . . . . . 599 . . . . . 607 . . . . . 630 . . . . . 648 . . . . . 654 . . . . . 650 . . . . . 647 . . . . . 636 . . . . . 602 . . . . . 557 . . . . . 494 . . . . . 454 . . . . . 336 . . . . . 249 . . . . . 38 . . . . . . 4 . . . . . . . 2 . . . . . . . 1 . . . . . . . 0 . . . . . . .

90 558 558 565 582 608 628 644 676 702 695 698 672 626 562 500 484 368 246 47 4 2 1 0

test no.: lli 0204-14c spacing criteria: 1.34

Candela Tabulation 0 0 . . . . . 1055 . . . . . 1 . . . . . 1054 . . . . . 3 . . . . . 1053 . . . . . 5 . . . . . 1050 . . . . . 7 . . . . . 1050 . . . . . 9 . . . . . 1051 . . . . . 11 . . . . 1057 . . . . . 13 . . . . 1062 . . . . . 15 . . . . 1061 . . . . . 17 . . . . 1051 . . . . . 19.5 . . . 1019 . . . . . 22.5 . . . 964 . . . . . . 25.5 . . . 958 . . . . . . 29 . . . . 925 . . . . . . 33 . . . . 856 . . . . . . 37.5 . . . 816 . . . . . . 42.5 . . . 631 . . . . . . 47.5 . . . 438 . . . . . . 55 . . . . 67 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .

45 1055 . . . . 1059 . . . . 1091 . . . . 1147 . . . . 1190 . . . . 1239 . . . . 1260 . . . . 1280 . . . . 1288 . . . . 1281 . . . . 1251 . . . . 1194 . . . . 1130 . . . . 1058 . . . . 964 . . . . . 881 . . . . . 694 . . . . . 532 . . . . . 88 . . . . . . 10 . . . . . . 6 . . . . . . . 3 . . . . . . . 0 . . . . . . .

90 1055 1058 1099 1166 1218 1261 1288 1297 1279 1239 1209 1177 1128 1083 996 970 797 582 108 9 5 4 0

67

6”


hs8pl fluorescent series 8” horizontal fluorescent shallow downlighting

new A. Height = 5” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 10” f. Length = 12-1/2”

5”

( SHALLOW )

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HS8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

8”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

8701-Reflector

8714-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8702-Baffle Reflector

8715-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

8703-Reflector/Fresnel Glass Lens

8716-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

8704-Reflector/Prismatic Glass Lens

8717-Baffle/Prismatic Plastic Lens

w

frost

8705-Baffle/Fresnel Glass Lens

8718-Reflector/Tempered Clear Plastic

mb

8706-Baffle/Prismatic Glass Lens

8719-Baffle/Tempered Clear Plastic

fuse

8707-Wall Wash Reflector

8709-Deco Glass Ring

rif

8708-Crossblade Reflector

8710-Double Ring

8712-Baffle/Frosted Glass Lens

8711-Triple Ring

Other Options

8713-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8709, 8710 MB Black SCH** Self-Flange Chrome and 8711. W White ** Only available on 8701 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HS8PL-1X18-FDB-T418-120-EMG 750-8701-CL-WH 68

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” horizontal fluorescent shallow trims 8708-CL

8701-CL

8702-WH-CL

8707-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

8703-CL

8714-CL

8704-CL

8715-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 9-1/8”

8” 8712-WH

8705-P

8706-WH

8713-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8716-CL

8717-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

8718-WT

8719-WH

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

69


8” horizontal fluorescent shallow trims

8”

70

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” horizontal fluorescent shallow trims 8721-CL

8722-CL

8723-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

8724-CL geo deco ring glass

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8727-CL

8725-CL

8726-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

8” 8710-CL

8711-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

8709-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

71


hh8pl fluorescent series 8” horizontal fluorescent downlighting

A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HH8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

8”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

8501-Reflector

8514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8502-Baffle Reflector

8515-Reflector/Tempered Glass Lens

p

shz*

red

intg 750

8503-Reflector/Fresnel Glass Lens

8516-Reflector/Prismatic Plastic Lens

wt

green

intg 1300

8504-Reflector/Prismatic Glass Lens

8517-Baffle/Prismatic Plastic Lens

w

frost

emg-d-750

8505-Baffle/Fresnel Glass Lens

8518-Reflector/Tempered Clear Plastic

mb

intg-d-750

8506-Baffle/Prismatic Glass Lens

8519-Baffle/Tempered Clear Plastic

ice-1300

8507-Wall Wash Reflector

8509-Deco Glass Ring

Other Options

8508-Crossblade Reflector

8510-Double Ring

fuse

8512-Baffle/Frosted Glass Lens

8511-Triple Ring

rif

8513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HH8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH 72

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hhr8pl fluorescent series 8” horizontal fluorescent remodel downlighting

A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 2-1/4”

DESCRIPTION:

TRIMS:

Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HHR8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

8”

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Glass

emg 750

8501-Reflector

8514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8502-Baffle Reflector

8515-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

8503-Reflector/Fresnel Glass Lens

8516-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

8504-Reflector/Prismatic Glass Lens

8517-Baffle/Prismatic Plastic Lens

w

frost

8505-Baffle/Fresnel Glass Lens

8518-Reflector/Tempered Clear Plastic

mb

Other Options

8506-Baffle/Prismatic Glass Lens

8519-Baffle/Tempered Clear Plastic

fuse

8507-Wall Wash Reflector

8509-Deco Glass Ring

rif

8508-Crossblade Reflector

8510-Double Ring

8512-Baffle/Frosted Glass Lens

8511-Triple Ring

8513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HHR8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

73


hhj8pl fluorescent series 8” horizontal fluorescent retrofit downlighting

A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8”

universal n installatio

(frame not included)

DESCRIPTION:

TRIMS:

Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 8-1/8” aperture.

3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

4. GROVE BAFFLE - One-piece aluminum with concentric rings.

2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HHJ8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

8”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

8501-Reflector

8514-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

8502-Baffle Reflector

8515-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

8503-Reflector/Fresnel Glass Lens

8516-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

8504-Reflector/Prismatic Glass Lens

8517-Baffle/Prismatic Plastic Lens

w

frost

8505-Baffle/Fresnel Glass Lens

8518-Reflector/Tempered Clear Plastic

mb

Other Options

8506-Baffle/Prismatic Glass Lens

8519-Baffle/Tempered Clear Plastic

fuse

8507-Wall Wash Reflector

8509-Deco Glass Ring

rif

8508-Crossblade Reflector

8510-Double Ring

8512-Baffle/Frosted Glass Lens

8511-Triple Ring

8513-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HHJ8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH 74

Glass

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” horizontal fluorescent trims 8508-CL

8501-CL

8502-WH-CL

8507-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

8503-CL

8514-CL

8504-CL

8515-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 9-1/8”

8” 8512-WH

8505-P

8506-WH

8513-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8516-CL

8517-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

8518-WT

8519-WH

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8501-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

75


8” horizontal fluorescent trims

8”

76

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


8” horizontal fluorescent trims 8521-CL

8522-CL

8523-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

8524-CL geo deco ring glass

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

8527-CL

8525-CL

8526-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

8” 8510-CL

8511-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 9-1/8”

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 9-1/8”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

8509-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8501-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

77


photometric data hh8pl-1x26-e-8501cl / hhr8pl-1x26-e-8501cl / hhj8pl-1x26-e-8501cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 1800

Zonal Lumens Summary Zone Lumens 0-300 663.38 0-400 1031.46 0-600 1268.04 0-900 1284.21 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1284.21

test no.: lli 0205-10m

total luminaire efficiency: 71.3%

%Lamp 36.9 57.3 70.4 71.3 0 0 0 0 71.3

Luminance Data (cd/sq.m)

%Fixt 51.7 80.3 98.7 100 0 0 0 0 100

spacing criteria: 1.18

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

7513 712 372 364 721

6135 767 372 364 721

7890 822 372 364 721

Zone Lumens 0-10 . . . . . . . . . . 63.16 10-20 . . . . . . . . . 238.75 20-30 . . . . . . . . . 361.46 30-40 . . . . . . . . . 368.08 40-50 . . . . . . . . . 207.31 50-60 . . . . . . . . . 29.26 60-70 . . . . . . . . . 9.28 70-80 . . . . . . . . . 3.89 80-90 . . . . . . . . . 3.01

Total Luminaire Efficiency = 71.3%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

48.5 21.6 12.1 7.8 5.4

7.7’ 11.6’ 15.5’ 19.3’ 23.2’

Initial Nadir Footcandles

Beam Spread

R oom C av i t y R a t io

Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 79 77 75 73 74 70 67 65 69 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance

79 74 68 63 58 54 50 46 43 40 37

76 71 66 61 56 52 48 45 42 39 36

73 68 64 59 55 51 47 44 41 38 36

71 65 59 54 49 44 41 37 34 31 29

79 72 65 60 54 50 45 42 38 36 33

79 71 63 57 51 47 42 39 35 33 30

76 70 64 58 53 49 45 41 38 35 33

76 69 62 56 51 51 42 38 35 32 30

73 68 62 57 52 48 44 41 38 35 32

73 67 61 55 50 46 42 38 35 32 30

Candela Tabulation 0 0 . . . . . 776 . . . . . . 1 . . . . . 793 . . . . . . 3 . . . . . 808 . . . . . . 5 . . . . . 804 . . . . . . 7 . . . . . 807 . . . . . . 9 . . . . . 806 . . . . . . 11 . . . . 812 . . . . . . 13 . . . . 814 . . . . . . 15 . . . . 791 . . . . . . 17 . . . . 730 . . . . . . 19.5 . . . 712 . . . . . . 22.5 . . . 766 . . . . . . 25.5 . . . 753 . . . . . . 29 . . . . 767 . . . . . . 33 . . . . 766 . . . . . . 37.5 . . . 436 . . . . . . 42.5 . . . 253 . . . . . . 47.5 . . . 85 . . . . . . . 55 . . . . 13 . . . . . . . 65 . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .

hh8pl-1x32-e-8501cl / hhr8pl-1x32-e-8501cl / hhj8pl-1x32-e-8501cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 2400

Zone Lumens 0-300 884.97 0-400 1375.99 0 0-60 1691.71 0 0-90 1712.49 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1712.49

8”

%Lamp 36.9 57.3 70.5 71.4 0 0 0 0 71.4

Luminance Data (cd/sq.m)

%Fixt 51.7 80.4 98.8 100 0 0 0 0 100

Ave. 00

Ave. 450

Ave. 900

45 550 650 750 850

10046 932 446 486 721

8179 986 521 486 721

10558 1096 521 486 721

0

spacing criteria: 1.18

Zonal Lumen Summary

Angle In Degrees

Zone Lumens 0-10 . . . . . . . . . . 84.26 10-20 . . . . . . . . . 318.49 20-30 . . . . . . . . . 484.22 30-40 . . . . . . . . . 491.02 40-50 . . . . . . . . . 276.68 50-60 . . . . . . . . . 39.04 60-70 . . . . . . . . . 12.18 70-80 . . . . . . . . . 5.11 80-90 . . . . . . . . . 3.48

Total Luminaire Efficiency = 71.4%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

64.8 28.8 16.2 10.4 7.2

7.7’ 11.6’ 15.5’ 19.3’ 23.2’

Initial Nadir Footcandles

Beam Spread

R oom C av i t y R a t io

Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 79 77 75 73 74 70 67 65 70 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance

79 74 68 63 58 54 50 46 43 40 37

76 71 66 61 56 52 48 45 42 39 36

73 68 64 59 55 51 47 44 41 38 36

71 65 59 54 49 44 41 37 34 31 29

79 72 65 60 54 50 45 42 38 36 33

79 71 63 57 51 47 42 39 35 33 30

76 70 64 58 53 49 45 41 38 35 33

76 69 62 56 51 51 42 38 35 32 30

73 68 62 57 52 48 44 41 38 35 32

73 67 61 55 50 46 42 38 35 32 30

Candela Tabulation 0 0 . . . . . 1036 . . . . . 1 . . . . . 1058 . . . . . 3 . . . . . 1078 . . . . . 5 . . . . . 1073 . . . . . 7 . . . . . 1076 . . . . . 9 . . . . . 1075 . . . . . 11 . . . . 1083 . . . . . 13 . . . . 1086 . . . . . 15 . . . . 1056 . . . . . 17 . . . . 974 . . . . . . 19.5 . . . 950 . . . . . . 22.5 . . . 1022 . . . . . 25.5 . . . 1005 . . . . . 29 . . . . 1023 . . . . . 33 . . . . 1021 . . . . . 37.5 . . . 581 . . . . . . 42.5 . . . 338 . . . . . . 47.5 . . . 114 . . . . . . 55 . . . . 17 . . . . . . . 65 . . . . 6 . . . . . . . . 75 . . . . 4 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .

hh8pl-1x42-e-8501cl / hhr8pl-1x42-e-8501cl / hhj8pl-1x42-e-8501cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 3200

Zone Lumens 0-300 1179.45 0-400 1833.82 0 0-60 2254.53 0 0-90 2282.77 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2282.77

%Lamp 36.9 57.3 70.5 71.3 0 0 0 0 71.3

%Fixt 51.7 80.3 98.8 100 0 0 0 0 100

Luminance Data (cd/sq.m) Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

13403 1260 669 607 1082

10913 1315 744 607 1082

14069 1418 744 607 1082

Zone Lumens 0-10 . . . . . . . . . . 112.3 10-20 . . . . . . . . . 424.51 20-30 . . . . . . . . . 642.64 30-40 . . . . . . . . . 654.37 40-50 . . . . . . . . . 368.71 50-60 . . . . . . . . . 52 60-70 . . . . . . . . . 16.39 70-80 . . . . . . . . . 6.95 80-90 . . . . . . . . . 4.9

Total Luminaire Efficiency = 71.3%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

86.3 38.3 21.6 13.8 9.6

7.7’ 11.6’ 15.5’ 19.3’ 23.2’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

78

R oom Ca v it y R a t io

Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

83 83 83 83 79 77 75 73 74 70 67 65 69 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance

79 74 68 63 58 54 50 46 43 40 37

76 71 66 61 56 52 48 45 42 39 36

73 68 64 59 55 51 47 44 41 38 36

71 65 59 54 49 44 41 37 34 31 29

79 72 65 60 54 50 45 42 38 36 33

79 71 63 57 51 47 42 39 35 33 30

76 70 64 58 53 49 45 41 38 35 33

76 69 62 56 51 51 42 38 35 32 30

90 1036 1047 1055 1065 1087 1103 1133 1169 1185 1155 1085 1168 1237 1265 1107 770 389 86 20 7 4 2 0

spacing criteria: 1.18

Zonal Lumen Summary

Angle In Degrees

45 1036 . . . . 1054 . . . . 1082 . . . . 1065 . . . . 1098 . . . . 1119 . . . . 1112 . . . . 1067 . . . . 1056 . . . . 1046 . . . . 1066 . . . . 1065 . . . . 1049 . . . . 1006 . . . . 927 . . . . . 607 . . . . . 289 . . . . . 79 . . . . . . 18 . . . . . . 7 . . . . . . . 4 . . . . . . . 2 . . . . . . . 0 . . . . . . .

test no.: lli 0205-10z

total luminaire efficiency: 71.3%

Zonal Lumens Summary

90 776 785 791 799 815 827 849 876 888 866 813 875 928 948 829 577 577 64 15 5 3 2 0

test no.: lli 0205-10y

total luminaire efficiency: 71.4%

Zonal Lumens Summary

45 776 . . . . . 790 . . . . . 811 . . . . . 798 . . . . . 823 . . . . . 839 . . . . . 834 . . . . . 800 . . . . . 792 . . . . . 784 . . . . . 799 . . . . . 798 . . . . . 787 . . . . . 754 . . . . . 695 . . . . . 455 . . . . . 455 . . . . . 59 . . . . . . 14 . . . . . . 5 . . . . . . . 3 . . . . . . . 2 . . . . . . . 0 . . . . . . .

73 68 62 57 52 48 44 41 38 35 32

73 67 61 55 50 46 42 38 35 32 30

Candela Tabulation 0 0 . . . . . 1380 . . . . . 1 . . . . . 1411 . . . . . 3 . . . . . 1437 . . . . . 5 . . . . . 1430 . . . . . 7 . . . . . 1434 . . . . . 9 . . . . . 1433 . . . . . 11 . . . . 1443 . . . . . 13 . . . . 1447 . . . . . 15 . . . . 1407 . . . . . 17 . . . . 1298 . . . . . 19.5 . . . 1266 . . . . . 22.5 . . . 1362 . . . . . 25.5 . . . 1339 . . . . . 29 . . . . 1364 . . . . . 33 . . . . 1361 . . . . . 37.5 . . . 775 . . . . . . 42.5 . . . 451 . . . . . . 47.5 . . . 152 . . . . . . 55 . . . . 23 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

45 1380 . . . . 405 . . . . . 1443 . . . . 1419 . . . . 1463 . . . . 1491 . . . . 1482 . . . . 1423 . . . . 1407 . . . . 1394 . . . . 1421 . . . . 1419 . . . . 1399 . . . . 1340 . . . . 1235 . . . . 809 . . . . . 386 . . . . . 105 . . . . . 24 . . . . . . 10 . . . . . . 5 . . . . . . . 3 . . . . . . . 0 . . . . . . .

90 1380 1395 1406 1420 1449 1470 1510 1558 1580 1539 1446 1556 1649 1686 1475 1026 518 115 27 10 5 3 0


photometric data hh8pl-2x26-e-8501cl / hhr8pl-2x26-e-8501cl / hhj8pl-2x26-e-8501cl lamp: 2 sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)

lumens: 3200 (2 lamps)

Zonal Lumens Summary Zone Lumens 0-300 912.95 0-400 1489.47 0-600 2179.66 0-900 2229.4 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 2229.4

%Lamp 25.4 41.4 60.5 61.9 0 0 0 0 61.9

test no.: lli 0205-10l

total luminaire efficiency: 61.9% Luminance Data (cd/sq.m)

%Fixt 41 66.8 97.8 100 0 0 0 0 100

spacing criteria: 1.38

Zonal Lumen Summary

Angle In Degrees

Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

15136 1699 669 607 1082

23138 1863 744 607 1082

29339 4603 818 607 1082

Zone Lumens 0-10 . . . . . . . . . . 80.1 10-20 . . . . . . . . . 332.63 20-30 . . . . . . . . . 500.22 30-40 . . . . . . . . . 576.51 40-50 . . . . . . . . . 542.65 50-60 . . . . . . . . . 147.54 60-70 . . . . . . . . . 37.05 70-80 . . . . . . . . . 7.69 80-90 . . . . . . . . . 5

Total Luminaire Efficiency = 61.9%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

62.5 27.8 15.6 10.0 6.9

8.3’ 12.4’ 16.6’ 20.7’ 24.9’

Initial Nadir Footcandles

Beam Spread

R oom C avi t y R a t io

Beam Angle: 92 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 74 74 74 74 1 69 67 65 64 2 65 61 58 55 3 60 55 51 48 4 56 50 46 43 5 52 46 41 38 6 49 42 37 34 7 45 38 34 30 8 42 35 31 27 9 40 32 28 25 10 37 30 26 23 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

72 72 72 72 68 66 64 63 63 60 57 55 59 54 51 48 55 49 45 42 51 45 41 38 48 41 37 34 44 38 33 30 42 35 30 27 39 32 28 25 37 30 25 23 RW - Wall Reflectance

69 63 58 53 48 44 40 37 34 31 29

66 61 56 51 47 43 39 36 33 31 29

63 59 54 50 45 42 38 35 33 30 28

62 56 50 44 40 35 32 29 26 23 21

69 62 55 50 45 40 36 33 30 27 25

69 61 53 47 42 37 33 30 27 25 22

66 60 54 48 44 39 36 32 30 27 25

66 59 52 46 41 37 33 30 27 25 22

63 58 52 47 43 39 35 32 29 27 25

63 57 51 46 41 36 33 30 27 24 22

hh8pl-2x32-e-8501cl / hhr8pl-2x32-e-8501cl / hhj8pl-2x32-e-8501cl lamp: 2 ge f32tbx/spx/841/a/4p/aol Candle Power Distribution (Candelas)

lumens: 4400 (2 lamps)

Zone Lumens 0-300 1031 0-400 1647.17 0 0-60 2459.18 0 0-90 2538.55 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2538.55

%Lamp 23.4 37.4 55.9 57.7 0 0 0 0 57.7

Luminance Data (cd/sq.m)

%Fixt 40.6 64.9 96.9 100 0 0 0 0 100

Ave. 00

Ave. 450

Ave. 900

45 550 650 750 850

27672 4384 744 607 1083

34918 8220 893 1093 2885

32073 6138 1190 1457 3607

0

Zone Lumens 0-10 . . . . . . . . . . 96.6 10-20 . . . . . . . . . 380.76 20-30 . . . . . . . . . 553.64 30-40 . . . . . . . . . 616.17 40-50 . . . . . . . . . 616.41 50-60 . . . . . . . . . 195.6 60-70 . . . . . . . . . 58.75 70-80 . . . . . . . . . 10.87 80-90 . . . . . . . . . 9.75

Total Luminaire Efficiency = 57.7%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

73.9 32.8 18.5 11.8 8.2

9.2’ 13.8’ 18.4’ 23.0’ 27.6’

Initial Nadir Footcandles

Beam Spread

R oom C av i t y R a t io

Beam Angle: 98 Degrees 4’ 6’ 8’ 10’ 12’

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

80% 70% 50% 30% 10%

0 69 69 69 69 1 65 63 61 59 2 60 57 54 51 3 56 51 48 45 4 52 46 42 39 5 48 42 38 35 6 45 39 34 31 7 42 35 31 28 8 39 32 28 25 9 37 30 26 23 10 35 28 24 21 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

67 67 67 67 63 61 60 58 59 56 53 51 55 50 47 44 51 46 42 39 47 42 38 35 44 38 34 31 41 35 31 28 38 32 28 25 36 30 26 23 34 27 23 21 RW - Wall Reflectance

64 59 54 49 44 41 37 34 31 29 27

61 57 52 47 43 39 36 33 31 28 26

59 55 50 46 42 38 35 33 30 28 26

58 52 46 41 36 33 29 26 24 22 20

64 58 51 46 41 37 33 30 28 25 23

64 56 49 43 38 34 31 28 25 23 21

61 56 50 45 40 36 33 30 27 25 23

61 55 48 43 38 34 30 27 25 23 21

59 54 49 44 40 36 32 30 27 25 23

59 53 47 42 38 34 30 27 25 22 21

hh8pl-2x42-e-8501cl / hhr8pl-2x42-e-8501cl / hhj8pl-2x42-e-8501cl lamp: 2 sylvania cf42dt/e/in/835 Candle Power Distribution (Candelas)

lumens: 6400 (2 lamps)

Zone Lumens 0-300 1257.58 0-400 1998.63 0 0-60 3060.22 0 0-90 3173.88 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 3173.88

%Lamp 19.6 31.2 47.8 49.6 0 0 0 0 49.6

%Fixt 39.6 63 96.4 100 0 0 0 0 100

Luminance Data (cd/sq.m) Ave. 00

Ave. 450

Ave. 900

450 550 650 750 850

39541 8713 1041 850 1443

43586 11344 1190 1822 5049

43030 8659 1636 2186 5410

Zone Lumens 0-10 . . . . . . . . . . 116.12 10-20 . . . . . . . . . 465.36 20-30 . . . . . . . . . 676.1 30-40 . . . . . . . . . 741.06 40-50 . . . . . . . . . 785.42 50-60 . . . . . . . . . 276.16 60-70 . . . . . . . . . 83.44 70-80 . . . . . . . . . 15.37 80-90 . . . . . . . . . 14.86

Total Luminaire Efficiency = 49.6%

Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW

Distance to Plane

88.1 39.1 22.0 14.1 9.8

9.5’ 14.3’ 19.1’ 23.8’ 28.6’

Initial Nadir Footcandles

Beam Spread

BEAM DIA. MEASURED AT 10% OF NADIR F.C.

Room C av it y R a ti o

Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’

80% 70% 50% 30% 10%

0 59 59 59 59 1 55 54 52 51 2 52 48 46 44 3 48 44 41 38 4 45 40 36 33 5 41 36 32 29 6 38 33 29 26 7 36 30 26 24 8 34 28 24 21 9 31 25 22 19 10 29 23 20 18 RC - Ceiling Cavity Reflectance

70% 70% 50% 30% 10%

50% 50% 30% 10%

30% 50% 30% 10%

10% 50% 30% 10%

0% 0%

58 58 58 58 54 53 51 50 50 48 45 43 47 43 40 38 43 39 36 33 40 35 32 29 38 32 29 26 35 30 26 23 33 27 24 21 31 25 22 19 29 23 20 18 RW - Wall Reflectance

55 50 46 42 38 35 32 29 27 25 23

53 49 44 40 37 34 31 28 26 24 22

51 47 43 39 36 33 30 28 25 24 22

50 45 39 35 31 28 25 22 20 18 17

55 49 44 39 35 31 28 26 23 21 20

55 48 42 37 33 29 26 23 21 19 17

53 48 43 38 34 31 28 25 23 21 19

53 47 41 36 32 29 26 23 21 19 17

45 1182 . . . . 1184 . . . . 1218 . . . . 1257 . . . . 1318 . . . . 1362 . . . . 1393 . . . . 1406 . . . . 1405 . . . . 1404 . . . . 1405 . . . . 1412 . . . . 1403 . . . . 1403 . . . . 1375 . . . . 1239 . . . . 981 . . . . . 590 . . . . . 150 . . . . . 12 . . . . . . 9 . . . . . . . 8 . . . . . . . 0 . . . . . . .

90 1182 1183 1227 1276 1342 1408 1448 1476 1490 1465 1422 1399 1378 1333 1299 1205 933 510 112 16 12 10 0

spacing criteria: 1.40

Zonal Lumen Summary

Angle In Degrees

Candela Tabulation 0 0 . . . . . 1182 . . . . . 1 . . . . . 1187 . . . . . 3 . . . . . 1181 . . . . . 5 . . . . . 1163 . . . . . 7 . . . . . 1186 . . . . . 9 . . . . . 1213 . . . . . 11 . . . . 1243 . . . . . 13 . . . . 1272 . . . . . 15 . . . . 1290 . . . . . 17 . . . . 1291 . . . . . 19.5 . . . 1256 . . . . . 22.5 . . . 1215 . . . . . 25.5 . . . 1232 . . . . . 29 . . . . 1259 . . . . . 33 . . . . 1234 . . . . . 37.5 . . . 1109 . . . . . 42.5 . . . 814 . . . . . . 47.5 . . . 431 . . . . . . 55 . . . . 80 . . . . . . . 65 . . . . 10 . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .

test no.: lli 0205-10x

total luminaire efficiency: 49.6%

Zonal Lumens Summary

90 1000 997 1017 1061 1119 1186 1255 1300 1345 1352 1305 1295 1296 1233 1199 1141 869 451 84 11 5 3 0

spacing criteria: 1.38

Zonal Lumen Summary

Angle In Degrees

45 1000 . . . . 986 . . . . . 952 . . . . . 936 . . . . . 980 . . . . . 1006 . . . . 1033 . . . . 1050 . . . . 1061 . . . . 1045 . . . . 1034 . . . . 1051 . . . . 1058 . . . . 1079 . . . . 1117 . . . . 1007 . . . . 695 . . . . . 346 . . . . . 34 . . . . . . 10 . . . . . . 5 . . . . . . . 3 . . . . . . . 0 . . . . . . .

test no.: lli 0205-10w

total luminaire efficiency: 57.7%

Zonal Lumens Summary

Candela Tabulation 0 0 . . . . . 1000 . . . . . 1 . . . . . 994 . . . . . . 3 . . . . . 947 . . . . . . 5 . . . . . 895 . . . . . . 7 . . . . . 879 . . . . . . 9 . . . . . 889 . . . . . . 11 . . . . 902 . . . . . . 13 . . . . 920 . . . . . . 15 . . . . 955 . . . . . . 17 . . . . 971 . . . . . . 19.5 . . . 936 . . . . . . 22.5 . . . 888 . . . . . . 25.5 . . . 841 . . . . . . 29 . . . . 974 . . . . . . 33 . . . . 986 . . . . . . 37.5 . . . 866 . . . . . . 42.5 . . . 542 . . . . . . 47.5 . . . 139 . . . . . . 55 . . . . 31 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .

51 46 42 37 34 30 28 25 23 21 19

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

51 45 40 36 32 28 26 23 21 19 17

Candela Tabulation 0 0 . . . . . 1409 . . . . . 1 . . . . . 1416 . . . . . 3 . . . . . 1430 . . . . . 5 . . . . . 1440 . . . . . 7 . . . . . 1459 . . . . . 9 . . . . . 1469 . . . . . 11 . . . . 1482 . . . . . 13 . . . . 1507 . . . . . 15 . . . . 1531 . . . . . 17 . . . . 1554 . . . . . 19.5 . . . 1570 . . . . . 22.5 . . . 1546 . . . . . 25.5 . . . 1535 . . . . . 29 . . . . 1517 . . . . . 33 . . . . 1478 . . . . . 37.5 . . . 1368 . . . . . 42.5 . . . 1096 . . . . . 47.5 . . . 683 . . . . . . 55 . . . . 159 . . . . . . 65 . . . . 14 . . . . . . . 75 . . . . 7 . . . . . . . . 85 . . . . 4 . . . . . . . . 90 . . . . 0 . . . . . . . .

45 1409 . . . . 1413 . . . . 1445 . . . . 1507 . . . . 1578 . . . . 1639 . . . . 1695 . . . . 1732 . . . . 1729 . . . . 1725 . . . . 1715 . . . . 1688 . . . . 1653 . . . . 1630 . . . . 1580 . . . . 1437 . . . . 1193 . . . . 768 . . . . . 207 . . . . . 16 . . . . . . 15 . . . . . . 14 . . . . . . 0 . . . . . . .

90 1409 1410 1457 1524 1601 1684 1747 1780 1793 1771 1726 1702 1668 1595 1540 1466 1207 729 158 22 18 15 0

79

8”


hh10pl fluorescent series 10” horizontal fluorescent downlighting

A. Height = 9-3/4” B. Trim Aperture = 9-3/4” c. Cut-out = 10-1/2” d. Trim Outside Dia. = 10-3/4” e. Width = 17-1/2” f. Length = 16-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HH10PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

10”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

2X32

-------

-------

FDB-T432-120-2

FDB-T432-277-2

2W-T432-120-2

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

2X42

-------

-------

FDB-T442-120-2

FDB-T442-277-2

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

1501-Reflector

wh

cl

emg 1300

1502-Baffle Reflector

p

shz*

intg 750

1503-Reflector/Fresnel Glass Lens

wt

intg 1300

1504-Reflector/Prismatic Glass Lens

w

emg-d-750

1505-Baffle/Fresnel Glass Lens

mb

intg-d-750

1506-Baffle/Prismatic Glass Lens

ice-1300

1512-Baffle/Frosted Glass Lens

fuse

1514-Reflector/Frosted Glass Lens

BAFFLE REFLECTOR RING WH White CL Clear WH Self-Flange White P Black WT Wheat Standard on all trims MB Black SCH** Self-Flange Chrome W White ** Only available on 1501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only

rif

1515-Reflector/Tempered Glass Lens

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Other Options

1513-Baffle/Tempered Glass Lens

(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HH10PL-1X18-FDB-T418-120-EMG 750-1501-CL-WH 80

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


10” horizontal fluorescent trims 1501-CL

1502-WH-CL

REFLECTOR

baffle w/ REFLECTOR

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

RING finish: Wh, SCH, shz

reflector finish: CL

1503-CL

1504-CL

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ prismatic glass lens

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

1505-P

1506-WH

baffle w/ fresnel glass lens

baffle w/ prismatic glass lens

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

1512-WH

1513-WH

baffle w/ frosted glass lens

baffle w/ tempered clear glass

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

1514-CL

1515-WT

REFLECTOR w/ frosted glass lens

reflector w/ tempered clear glass

trim o. d.: 10-3/4”

trim o. d.: 10-3/4”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

10”

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 1501-WH-INTG

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

81


hw6pl fluorescent series 6” fluorescent lensed wall wash downlighting

A. Height = 6” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff.

3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation.

LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location.

4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HW6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)

6”

LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options emg 750

Trim Type & Description

Reflector

6555-Lensed Wall Wash Reflector

Ring

cl

emg 1300

shz

emg-d-750

wt

ice-1300

w

WH

mb Other Options fuse rif

REFLECTOR CL Clear

RING WH Self-Flange White

WT MB W SHZ

Standard on all trims

Wheat Black White Satin Haze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HW6PL-1X18-FDB-T418-120-EMG 750-6555-CL-WH 82

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


hw8pl fluorescent series 8” fluorescent lensed wall wash downlighting

A. Height = 7-1/2” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2”

DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HW8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

8”

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

2X18

-------

-------

FDB-T418-120-2

FDB-T418-277-2

2W-T418-120-2

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

2X26

-------

-------

FDB-T426-120-2

FDB-T426-277-2

2W-T426-120-2

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options emg 750

Trim Type & Description

Reflector

8555-Lensed Wall Wash Reflector

cl

emg 1300

shz

emg-d-750

wt

ice-1300

w

Ring WH

mb Other Options fuse rif

REFLECTOR CL Clear

RING WH Self-Flange White

WT MB W SHZ

Standard on all trims

Wheat Black White Satin Haze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HW8PL-1X18-FDB-T418-120-EMG 750-8555-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

83


sloped ceiling adapter msca - maxilume sloped ceiling adapter

features: • The Sloped Ceiling Adapter provides an effective and attractive interface between sloped ceilings and Maxilume series of recessed downlighting. • Each adapter is scaled specifically to the aperture diameter of the luminaire. • The adapter may be specified for 10 – 30 degree slopes, in 5 degree increments. • The self-flanged, heavy gauge aluminum adapter is coated with a white, textured polyester powder finish for durability. • Mechanical design provides simplified installation with integral tabs. • Integral tabs support the adapter to the recessed downlight housing prior to installation of the trim.

sloped ceiling adapter ordering information and dimensional data degree of slope (pitch) sloped ceiling adapter

ceiling opening (dia.)

10º (2/12)

15º (3/12)

20º (4&5/12)

25º (6/12)

30º (7/12)

major axis height adder msca6

11” ( 27.9 cm )

3-7/8” ( 9.8 cm )

3-7/8” ( 9.8 cm )

3-7/8” ( 9.8 cm )

3-7/8” ( 9.8 cm )

3-7/8” ( 9.8 cm )

msca8

12-5/8” ( 32.1 cm )

4-1/4” ( 10.8 cm )

4-1/4” ( 10.8 cm )

4-1/4” ( 10.8 cm )

4-1/4” ( 10.8 cm )

4-1/4” ( 10.8 cm )

ordering information: (Please check the boxes below for the option desired) Series msca

Aperture

Degree of Slope

6”

10D

8”

15D 20D 25D 30D

84

Example: MSCA - 6 -10D

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


architectural downlighting

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

85


california title 24 compliant

elite lighting offers a wide range of products to comply with the new california title 24 residential lighting standards

These products are designed to respond to California’s energy crisis, reduce energy bills, increase energy delivery system reliability, energy efficiency measures that save energy at peak periods, and contribute to an improved economic condition for the state.

86

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” series compact fluorescent downlighting

engineered to perform. designed to save time. 6” air-shut downlighting Standard wago quick connects eliminate the need for wire nuts.

Pre-installed double headed nails and 90º pivot end ensure quick mounting and increased productivity.

The Elite bar hangers allow the fixture to be mounted within a full range of spacing. From a minimum of 9” to a maximum of 25”.

90º pivot ends

Hemmed bar hangers allow easy handling and special screw on frame allows secure locking.

Pre-installed double headed nails and 90º pivot end ensure quick mounting and increased productivity.

The Elite bar hangers allow the fixture to be mounted within a full range of spacing. From a minimum of 9” to a maximum of 25”.

Standard wago quick connects eliminate the need for wire nuts.

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

Hemmed bar hangers allow easy handling and special screw on frame allows secure locking.

87


hv4plic-at 4” vertical fluorescent ic downlighting

A. Min. Height = 7-3/4” B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.

5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:

2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.

4”

6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

HV4PLic-at - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

------

-------

-------

-------

-------

-------

------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

emg 750

4101-Reflector

4114-Reflector/Frosted Glass Lens

wh

cl

blue

emg 1300

4102-Baffle Reflector

4115-Reflector/Tempered Glass Lens

p

shz*

red

emg-d-750

4103-Reflector/Fresnel Glass Lens

4116-Reflector/Prismatic Plastic Lens

wt

green

ice-1300

4104-Reflector/Prismatic Glass Lens

4117-Baffle/Prismatic Plastic Lens

w

frost

4105-Baffle/Fresnel Glass Lens

4118-Reflector/Tempered Clear Plastic

mb

4106-Baffle/Prismatic Glass Lens

4119-Baffle/Tempered Clear Plastic

fuse

4107-Wall Wash Reflector

4109-Deco Glass Ring

rif

4108-Crossblade Reflector

4110-Double Ring

4112-Baffle/Frosted Glass Lens

4111-Triple Ring

Other Options

4113-Baffle/Tempered Glass Lens

BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

Example: HV4PLIc-at-1X18-FDB-T418-120-EMG 750-4101-CL-WH 88

Glass

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


4” vertical fluorescent trims 4108-CL

4101-CL

4102-WH-CL

4107-SHZ

REFLECTOR

baffle w/ REFLECTOR

wall wash REFLECTOR

crossblade REFLECTOR

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wH, P

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, SHZ, w

RING finish: Wh, SCH, shz

reflector finish: CL

RING finish: Wh, SCH, shz

RING finish: Wh

4103-CL

4114-CL

4104-CL

4115-WT

REFLECTOR w/ prismatic glass lens

reflector w/ tempered clear glass

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

REFLECTOR w/ fresnel glass lens

REFLECTOR w/ frosted glass lens

trim o. d.: 5-1/2”

4” 4112-WH

4105-P

4106-WH

4113-WH

baffle w/ fresnel glass lens

baffle w/ frosted glass lens

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

4116-CL

4117-WH

REFLECTOR w/ prismatic plastic lens

baffle w/ prismatic PLASTIC lens

4118-WT

4119-WH

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

baffle w/ prismatic glass lens

baffle w/ tempered clear glass

reflector w/ tempered clear plastic

baffle w/ tempered clear plastic

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

baffle finish: wh, p

RING finish: Wh

RING finish: Wh

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

89


4” vertical fluorescent trims 4121-CL

4122-CL

4123-CL

stardust deco ring glass

euro deco ring glass

prism deco ring glass

new

new

new

4124-CL geo deco ring glass

new

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

RING finish: Wh

4127-CL

4125-CL

4126-CL

central etched float glass

diffusing screen wall wash glass

geo deco ring glass

new

new

new

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh

RING finish: Wh

RING finish: Wh

4” 4110-CL

4111-CL

deco glass reflector

double ring glass

triple ring glass

trim o. d.: 5-1/2”

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

trim o. d.: 5-1/2”

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

REFlector finish: CL, Wt, MB, SHZ, w

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

RING finish: Wh, shz

GLASS finish: Blue, red, green, frost

GLASS finish: Blue, red, green, frost

4109-CL

Blue

Blue

Blue

red

red

red

green

green

green

frost

frost

frost

(actual color may vary)

90

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


4” vertical fluorescent trims

4”

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

91


b4pl-e 4” miniature compact fluorescent non-ic downlighting

DESCRIPTION: Small aperture thermally protected, specification grade compact fluorescent recessed housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a

4”

double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

B4PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

B401-Stepped Baffle

B471-Square Baffle

w

cl

wh

emg 1300

B402-Reflector

B472-Square Reflector

p

shz

bk

emg-d-750

B406-Wall Wash/ Baffle

B444-Frosted Lens/Reflector

sn

wt

sn

ice-1300

B407-Wall Wash/Reflector

B462-Frosted Lens/Reflector

cp

w

cp

B420-Glass Trim

B454-Clear Lens/Reflector

bz

mb

ch

B438-Designer Point

B452-Albalite Lens

sn

pb

fuse

B437-Smooth Frost

B455-Fresnel Lens

rif

B439-Smooth Frost Dome

B451-Drop Opal Lens

Other Options

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B4PL-E-1X18-FDB-T418-120-EMG 750-B401-BZ-BZ 92

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b4plR-e 4” miniature compact fluorescent non-ic remodel downlighting

DESCRIPTION: Small aperture, thermally protected, specification grade compact fluorescent recessed housing. For remodel application non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs, and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing.

ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.

B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.

E. Junction box - ETL listed for feed through wiring with eight 1/2” KOs and four Romex knockouts with strain relief.

C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.

listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

D. Installation - Four Preinstalled spring clips which secure the housing firmly into

4”

B4PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

B401-Stepped Baffle

B471-Square Baffle

w

cl

wh

emg 1300

B402-Reflector

B472-Square Reflector

p

shz

bk

emg-d-750

B406-Wall Wash/ Baffle

B444-Frosted Lens/Reflector

sn

wt

sn

ice-1300

B407-Wall Wash/Reflector

B462-Frosted Lens/Reflector

cp

w

cp

B420-Glass Trim

B454-Clear Lens/Reflector

bz

mb

ch

B438-Designer Point

B452-Albalite Lens

sn

pb

fuse

B437-Smooth Frost

B455-Fresnel Lens

rif

B439-Smooth Frost Dome

B451-Drop Opal Lens

Other Options

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B4PLR-E-1X18-FDB-T418-120-EMG 750-B402-SN-SN www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

93


4” compact fluorescent trims b401cp-cp

b471cp-wh

b437wh

Stepped Baffle

square Stepped Baffle

smooth frost shower lite

new

new

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

baffle finish: p, w, sn, cp, bz

baffle finish: p, w, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

covered by u.s. patent

patent pending

b402cp-wh

b473cp-wh

b462cl-ch

reflector

square reflector

frosted lens with reflector

new

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

REFlector finish: mb, cl, rg, w, cp, sn

REFlector finish: mb, cl, rg, w, cp, sn

REFlector finish: mb, cl, rg, w, cp, sn

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

patent pending

4” b406p-wh

b407cl-wh

b454cp-wh

wall wash with Baffle

wall wash with reflector

clear lens with reflector

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

baffle finish: p, w, sn, cp, bz

REFlector finish: mb, cl, rg, w, cp, sn

REFlector finish: mb, cl, rg, w, cp, sn

RING/cover finish: bk, Wh

RING/cover finish: bk, Wh

RING finish: bk, Wh, ch, pb, sn, cp, bz

b420-red

b438wh

b455pb

glass trim

designer point shower lite

fresnel lens

new

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

trim o. d.: 4-7/8”

glass finish: green, yellow, pink, brown, white, orange, navy blue

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

94

covered by u.s. patent

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


4” compact fluorescent trims b439wh smooth frost dome shower lite

new

trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz covered by u.s. patent

b444cl-wh square frosted lens with reflector

new

trim o. d.: 4-7/8” REFlector finish: mb, cl, rg, w, cp, sn RING finish: bk, Wh, ch, pb, sn, cp, bz patent pending

4”

b452cp albalite lens

trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz

b451pb drop opal lens

trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

95


b5plic-e 5” compact fluorescent ic downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 9W, 13W, 18W or 26W compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a

5”

double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for direct contact with insulation, through-branch circuit wiring, and damp locations. Wet location only with lens trims.

B5PLIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b530-Baffle

b541-Reflector/Albalite Lens

w

cl

wh

emg 1300

b507-Reflector

b542-Reflector/Fresnel Lens

p

shz

bk

emg-d-750

b565-Cone Reflector/Baffle

b504L-Plastic Shower Lens

sn

wt

sn

ice-1300

b504-Shower Trim

b501L-Plastic Albalite Lens

cp

w

cp

b501-Albalite Lens

b505L-Plastic Fresnel Lens

bz

mb

ch

b505-Fresnel Lens

b520-Glass Trim

sn

pb

Other Options fuse

b525-Baffle/Frosted Dome

rif

b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B5PLIC-E-1X18-FDB-T418-120-EMG 750-B530-W-WH 96

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b5plric-e 5” compact fluorescent ic remodel downlighting

DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Accommodates (1) 9W, 13W, 18W or 26W compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed all aluminum construction for maximum heat dissipation and rust protection.

D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.

B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.

E. Junction box - ETL listed for feed through wiring provided with eight 1/2” KOs and four Romex knockouts with strain relief.

C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.

listing ETL and C-ETL listed for direct contact with insulation, through-branch circuit wiring, and damp locations. Wet location only with lens trims.

5”

B5PLric-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b530-Baffle

b541-Reflector/Albalite Lens

w

cl

wh

emg 1300

b507-Reflector

b542-Reflector/Fresnel Lens

p

shz

bk

emg-d-750

b565-Cone Reflector/Baffle

b504L-Plastic Shower Lens

sn

wt

sn

ice-1300

b504-Shower Trim

b501L-Plastic Albalite Lens

cp

w

cp

b501-Albalite Lens

b505L-Plastic Fresnel Lens

bz

mb

ch

b505-Fresnel Lens

b520-Glass Trim

sn

pb

Other Options fuse

b525-Baffle/Frosted Dome

rif

b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PLRIC-E-1X18-FDB-T418-120-EMG 750-B507-CL-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

97


b5pl-e 5” compact fluorescent non-ic downlighting

DESCRIPTION: Small aperture thermally protected, specification grade compact fluorescent recessed housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a

5”

double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

B5PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b530-Baffle

b541-Reflector/Albalite Lens

w

cl

wh

emg 1300

b507-Reflector

b542-Reflector/Fresnel Lens

p

shz

bk

emg-d-750

b565-Cone Reflector/Baffle

b504L-Plastic Shower Lens

sn

wt

sn

ice-1300

b504-Shower Trim

b501L-Plastic Albalite Lens

cp

w

cp

b501-Albalite Lens

b505L-Plastic Fresnel Lens

bz

mb

ch

b505-Fresnel Lens

b520-Glass Trim

sn

pb

Other Options fuse

b525-Baffle/Frosted Dome

rif

b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B5PL-E-1X18-FDB-T418-120-EMG 750-B530-W-WH 98

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b5plr-e 5” compact fluorescent non-ic remodel downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a

double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

5”

B5PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b530-Baffle

b541-Reflector/Albalite Lens

w

cl

wh

emg 1300

b507-Reflector

b542-Reflector/Fresnel Lens

p

shz

bk

emg-d-750

b565-Cone Reflector/Baffle

b504L-Plastic Shower Lens

sn

wt

sn

ice-1300

b504-Shower Trim

b501L-Plastic Albalite Lens

cp

w

cp

b501-Albalite Lens

b505L-Plastic Fresnel Lens

bz

mb

ch

b505-Fresnel Lens

b520-Glass Trim

sn

pb

Other Options fuse

b525-Baffle/Frosted Dome

rif

b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B5PLR-E-1X18-FDB-T418-120-EMG 750-B507-CL-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

99


5” compact fluorescent trims

5”

100

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


5” compact fluorescent trims b530cp-cp

b507cp-wh

b535p-wh

b536w-wh

Baffle

reflector

Baffle with albalite lens

Baffle with fresnel lens

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz

available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch, sn-sn, bz-bz

available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz

available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz

b565w-cl

b565p-rg

b541rg-wh

b542cl-wh

cone reflector with Baffle

cone reflector with Baffle

reflector with albalite lens

reflector with fresnel lens

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

finish options: w-cl, p-cl

finish options: w-rg, p-rg

available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch,

available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch,

5” b504wh

b501cp

b504l

b501l

shower trim

albalite lens

plastic shower trim

plastic albalite lens

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

trim finish: white plastic

trim finish: white plastic

b505sn

b525wh

b505l

b520-green

fresnel lens

Baffle with frosted dome

plastic fresnel lens

glass trim

new

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

trim o. d.: 6-1/4”

RING finish: bk, Wh, ch, pb, sn, cp, bz

available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz

trim finish: white plastic

glass finish: blue, yellow, pink, brown, white, red, orange, navy blue

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

101


b6plic-e 6” compact fluorescent ic downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceilings. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis

6”

of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - UL and ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.

B6PLic-e - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b725

b620

b755

b758

b789

w

cl

wh

emg 1300

b731

b723

b756

b759

b705l

p

shz

bk

emg-d-750

b722

b703

b741

b760

b706l

sn

wt

sn

ice-1300

af640

b704

b742

b781

b707l

cp

w

cp

b721

b751

b743

b787

bz

mb

ch

af632

b752

b707

b782

sn

pb

fuse

b701

b753

b737

b788

rif

b702

b705

b735

b785

b729

b706

b736

b796

b724

b754

b757

b780

Other Options

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PLIC-E-1X18-FDB-T418-120-EMG 750-B725-W-WH 102

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b6plric-e 6” compact fluorescent ic remodel downlighting

DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Accommodates (1) 4-pin compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed all aluminum construction for maximum heat dissipation and rust protection.

D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.

B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.

E. Junction box - ETL listed for feed through wiring and provided with eight 1/2” KOs and four Romex knockouts with strain relief.

C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.

listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.

6”

B6PLRIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b725

b620

b755

b758

b789

w

cl

wh

emg 1300

b731

b723

b756

b759

b705l

p

shz

bk

emg-d-750

b722

b703

b741

b760

b706l

sn

wt

sn

ice-1300

af640

b704

b742

b781

b707l

cp

w

cp

b721

b751

b743

b787

bz

mb

ch

af632

b752

b707

b782

sn

pb

fuse

b701

b753

b737

b788

rif

b702

b705

b735

b785

b729

b706

b736

b796

b724

b754

b757

b780

Other Options

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PLRIC-E-1X18-FDB-T418-120-EMG 750-B725-W-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

103


b6pl-e 6” compact fluorescent non-ic downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge cold rolled steel construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis

6”

of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - Listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

B6PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b725

b620

b755

b758

b789

w

cl

wh

emg 1300

b731

b723

b756

b759

b705l

p

shz

bk

emg-d-750

b722

b703

b741

b760

b706l

sn

wt

sn

ice-1300

af640

b704

b742

b781

b707l

cp

w

cp

b721

b751

b743

b787

bz

mb

ch

af632

b752

b707

b782

sn

pb

fuse

b701

b753

b737

b788

rif

b702

b705

b735

b785

b729

b706

b736

b796

b724

b754

b757

b780

Other Options

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PL-E-1X18-FDB-T418-120-EMG 750-B725-w-WH 104

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b6plr-e 6” compact fluorescent non-ic remodel downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent housing. For new construction, non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge cold rolled steel construction for maximum heat dissipation and rust protection.

D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling and accommodate different ceiling thicknesses from 1/2” to 1-3/8”.

B. Socket - One vertically mounted plug-in socket for CFL lamp. Preinstalled on an adjustable mounting bracket to allow for proper and consistent lamp positioning.

E. Junction box - ETL listed for feed through wiring and provided with eight 1/2” KOs and four Romex knockouts with strain relief.

C. Ballast - Thermally protected, current controlled rapid start ballast, will produce full light output, increase lamp life with no noise and flicke. Ballast supplied is manufactured by Lutron.

listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.

6”

B6PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

1X42

-------

-------

FDB-T442-120-1

FDB-T442-277-1

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b725

b620

b755

b758

b789

w

cl

wh

emg 1300

b731

b723

b756

b759

b705l

p

shz

bk

emg-d-750

b722

b703

b741

b760

b706l

sn

wt

sn

ice-1300

af640

b704

b742

b781

b707l

cp

w

cp

b721

b751

b743

b787

bz

mb

ch

af632

b752

b707

b782

sn

pb

fuse

b701

b753

b737

b788

rif

b702

b705

b735

b785

b729

b706

b736

b796

b724

b754

b757

b780

Other Options

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PLR-E-1X18-FDB-T418-120-EMG 750-B725-W-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

105


b6plic-26 or 32-e 6” double-wall compact fluorescent ic downlighting

DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 26W or 32W 4pin compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Outer Housing - Die formed aluminum construction for maximum heat dissipating air chamber on top of the housing. Junction box could be accessed from inside and outside housing.

6”

B. Inner Housing - Die-formed, all aluminum construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling.

E. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary.

C. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.

F. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps.

D. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.

listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.

B6PLIC-26 or 32-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

-------

-------

-------

-------

-------

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

1X32

HL3-T432-120-1

HL3-T432-277-1

FDB-T432-120-1

FDB-T432-277-1

2W-T432-120-1

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b725

b620

b755

b758

b789

w

cl

wh

emg 1300

b731

b723

b756

b759

b705l

p

shz

bk

emg-d-750

b722

b703

b741

b760

b706l

sn

wt

sn

ice-1300

af640

b704

b742

b781

b707l

cp

w

cp

b721

b751

b743

b787

bz

mb

ch

af632

b752

b707

b782

sn

pb

fuse

b701

b753

b737

b788

rif

b702

b705

b735

b785

b729

b706

b736

b796

b724

b754

b757

b780

Other Options

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B6PLIC-26-E-FDB-T426-120-EMG 750-B725-W-WH 106

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” compact fluorescent trims b725w-wh

b731w-wh

Baffle with frosted dome

full cone Baffle

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

baffle finish: p, w, sn, cp, bz

available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

b722w-cl

b702p-rg

cone reflector with Baffle

cone reflector with Baffle

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

available color combinations: w-cl-wh, p-cl-wh, w-w-wh

baffle finish: p, w reflector finish: cl, rg

6”

RING finish: bk, Wh, ch, pb, sn, cp, bz

b721cl-wh

b701cp-wh

cone reflector

cone reflector

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch, sn-sn

reflector finish: mb, cl, rg, w, cp, sn

af640w-wh

af632rg-wh

deep self-flange air-shut baffle

air-shut reflector

RING finish: bk, Wh, ch, pb, sn, cp, bz

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz, p-bk

available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mbbk, rg-pb, cl-ch, sn-sn

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

107


6” compact fluorescent trims b620-orange

b729w-wh

glass trim

Baffle wall wash

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

glass finish: green, yellow, pink, brown, white, red, blue, navy blue

available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz

b724w-cl

b723mb-wh

reflector Baffle wall wash

wall wash reflector

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

available color combinations: w-cl-wh, p-cl-wh, w-w-wh

available color combinations: cl-wh, cl-ch, rg-wh, rg-pb, w-wh, mb-wh, cp-cp, sn-sn

wall wash cover: bk, Wh

6”

wall wash cover: bk, Wh

wall wash cover: bk, Wh

b704p-rg

b703rg-wh

b705cp

b706pb

reflector Baffle wall wash

wall wash reflector

metal albalite lens

metal fresnel lens

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

trim o. d.: 8”

trim o. d.: 8”

baffle finish: p, w

available color combinations: cl-wh, cl-ch, rg-wh, rg-pb, w-wh, mb-wh, cp-cp, sn-sn

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

reflector finish: cl, rg wall wash cover: bk, Wh

wall wash cover: bk, Wh

b751wh

b752wh

b753wh

b754wh

smooth frost dome shower lens

designer point shower lens

designer cone shower lens

smooth frost shower lens

new

new

new

new

trim o. d.: 8”

trim o. d.: 8”

trim o. d.: 8”

trim o. d.: 8”

lens: frosted

lens: frosted/clear

lens: frosted

lens: frosted

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

108

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” compact fluorescent trims

b755w-wh

b756cl-wh

b741rg-wh

b742rg-wh

Baffle with prismatic lens

reflector with prismatic lens

reflector with albalite lens

reflector with fresnel lens

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

baffle finish: p, w, sn, cp, bz

reflector finish: mb, cl, rg, w, cp, sn

reflector finish: mb, cl, rg, w, cp, sn

reflector finish: mb, cl, rg, w, cp, sn

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

MAX. 26W

MAX. 26W

MAX. 26W

MAX. 26W

b743rg-wh

b707cp

b737w-wh

b735p-wh

reflector with drop opal lens

metal drop opal lens

Baffle with drop opal lens

Baffle with albalite lens

trim o. d.: 7-1/4”

trim o. d.: 8”

trim o. d.: 7-1/4”

trim o. d.: 7-1/4”

reflector finish: mb, cl, rg, w, cp, sn

RING finish: bk, Wh, ch, pb, sn, cp, bz

baffle finish: p, w, sn, cp, bz

baffle finish: p, w, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

6”

MAX. 26W

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

109


6” compact fluorescent trims b736w-wh Baffle with fresnel lens

trim o. d.: 7-1/4” baffle finish: p, w, sn, cp, bz RING finish: bk, Wh, ch, pb, sn, cp, bz

MAX. 26W b705l plastic albalite lens

trim o. d.: 8” RING finish: white plastic

6” b706l plastic fresnel lens

trim o. d.: 8” RING finish: white plastic

b707l plastic drop opal lens

trim o. d.: 8” RING finish: white plastic

110

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” compact fluorescent trims b757w-wh

b781CP-wh

b787cp-wh

Baffle with frosted dome shower lens

square Baffle trim

square reflector trim

new

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/2”

trim o. d.: 7-1/2”

baffle finish: p, w, sn, cp, bz

baffle finish: p, w, sn, cp, bz

reflector finish: mb, cl, rg, w, cp, sn

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

patent pending

patent pending

MAX. 26W covered by u.s. patent

b758cl-wh

b782cl-wh

b788wh

reflector with frosted dome shower lens

square reflector/baffle trim

square albalite lens

new

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/2”

trim o. d.: 7-1/2”

reflector finish: mb, cl, rg, w, cp, sn

baffle finish: p, w, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

MAX. 26W

patent pending

patent pending

6”

covered by u.s. patent

b759cl-wh

b785wh

b796wh

reflector with frosted lens

square fresnel lens

square smooth frost dome lens

new

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/2”

trim o. d.: 7-1/2”

reflector finish: mb, cl, rg, w, cp, sn

lens: frosted

lens: frosted

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

patent pending

patent pending

MAX. 26W covered by u.s. patent

b760w-wh

b780wh

b789wh

Baffle with frosted lens

square designer point lens

square designer cone lens

new

new

new

trim o. d.: 7-1/4”

trim o. d.: 7-1/2”

trim o. d.: 7-1/2”

baffle finish: p, w, sn, cp, bz

lens: frosted/clear

lens: frosted

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

patent pending

patent pending

MAX. 26W covered by u.s. patent

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333

111


b36plic-e 6” compact fluorescent slope ceiling ic downlighting

2/12 to 6/12 Pitch (9º to 27º)

DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Designed for sloped ceiling applications where ceiling pitch ranges from 2/12 to 6/12 (9º to 27º). Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceilings. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. c. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary.

6”

d. Junction box - UL and ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. e. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. Listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.

B36PLIC - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b391-Stepped Baffle

w

cl

wh

emg 1300

b397-Reflector

p

shz

bk

emg-d-750

b601-Metal Albalite Shower

sn

wt

sn

ice-1300

b605-Metal Fresnel Shower

cp

w

cp

b601L-Plastic Albalite Shower

bz

mb

ch

sn

pb

Other Options

b605L-Plastic Fresnel Shower

bz

fuse rif

BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B36PLIC-E-1X18-FDB-T418-120-EMG 750-B391-P-WH 112

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


b36plric-e 6” compact fluorescent slope ceiling ic remodel downlighting

2/12 to 6/12 Pitch (9º to 27º)

DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Designed for sloped ceiling applications where the ceiling pitch ranges from 2/12 to 6/12. Accommodates (1) compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed, all aluminum construction for maximum heat dissipation and rust protection. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate different ceiling thicknesses from 1/2” to 1-3/8”.

e. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. Listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.

d. Junction box - Provided with eight 1/2” KOs and four Romex knockouts with strain reliefs.

6”

B36PLRIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:

HI-Lume - 120V (1% Dimming)

HI-Lume - 277V (1% Dimming)

Compact SE - 120V (5% Dimming)

Compact SE - 277V (5% Dimming)

Tu-Wire - 120V only (5% Dimming)

1X18

-------

-------

FDB-T418-120-1

FDB-T418-277-1

-------

1X26

HL3-T426-120-1

HL3-T426-277-1

FDB-T426-120-1

FDB-T426-277-1

2W-T426-120-1

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

-------

(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)

Emergency Options

Trim Type & Description

Baffle

Reflector

Ring/Trim

emg 750

b391-Stepped Baffle

w

cl

wh

emg 1300

b397-Reflector

p

shz

bk

emg-d-750

b601-Metal Albalite Shower

sn

wt

sn

ice-1300

b605-Metal Fresnel Shower

cp

w

cp

b601L-Plastic Albalite Shower

bz

mb

ch

sn

pb

Other Options

b605L-Plastic Fresnel Shower

bz

fuse rif

BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze

(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)

reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel

ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze

For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

Example: B36PLRIC-E-1X18-FDB-T418-120-EMG 750-B397-RG-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

113


6” compact slope fluorescent trims b391p-wh

b397rg-wh

stepped Baffle

reflector

trim o. d.: 7-1/2”

trim o. d.: 7-1/2”

baffle finish: p, w

reflector finish: mb, cl, rg, w

RING finish: wh

RING finish: wh

b601cp

b605pb

metal albalite lens

metal fresnel lens

trim o. d.: 8”

trim o. d.: 8”

RING finish: bk, Wh, ch, pb, sn, cp, bz

RING finish: bk, Wh, ch, pb, sn, cp, bz

b601l

b605l

plastic albalite lens

plastic fresnel lens

trim o. d.: 8”

trim o. d.: 8”

RING finish: white plastic

RING finish: white plastic

6”

114

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


6” compact slope fluorescent trims

www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333

115


emergency battery pack description, part number and lumen output EMG 750 Emergency battery pack with remote test switch. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B94C-2-2 or IOTA I42EM-J. EMG –D-750 Emergency battery pack with remote test switch. To be used in damp location areas. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine BDL94C-2-2 or IOTA I42EM-R-DL. INTG 750 Emergency battery pack with integral test switch. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B94C-2-6 or IOTA I42EM-R-J. INTG-D 750 Emergency battery pack with integral test switch. To be used in damp location areas. Operates 1 lamp in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine BDL94C-2-6 or IOTA I42EM-R-J-DL.

BODINE B94C/ BDL94C lamp type (4-pin) part number

IOTA I-42/ IOTA I-42 -DL lumens 1 lamp

lumens

lamp type (4-pin) part number

2 lamps

1 lamp

2 lamps

GE: F13DBX, SYLVANIA: CF13DD/E

350

425

GE: F13DBX, SYLVANIA: CF13DD/E

350

400

GE: F13TBX, SYLVANIA: CF13DT/E

350

425

GE: F13TBX, SYLVANIA: CF13DT/E

350

400

GE: F18DBX, SYLVANIA: CF18DD/E

475

575

GE: F18DBX, SYLVANIA: CF18DD/E

350

550

GE: F18TBX, SYLVANIA: CF18DT/E/IN

300

525

GE: F18TBX, SYLVANIA: CF18DT/E/IN

350

500

GE: F26DBX, SYLVANIA: CF26DD/E

600

700

GE: F26DBX, SYLVANIA: CF26DD/E

425 N/A

GE: F26TBX, SYLVANIA: CF26DT/E/IN

450

725

GE: F26TBX, SYLVANIA: CF26DT/E/I

425 N/A

GE: F32TBX, SYLVANIA: CF32DT/E/IN

575

750

GE: F32TBX, SYLVANIA: CF32DT/E/IN

600 N/A

GE: F42TBX, SYLVANIA: CF42DT/E/IN

750 N/A

GE: F42TBX, SYLVANIA: CF42DT/E/IN

750 N/A

EMG 1300 Super Emergency battery pack with remote test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B84CG-2-2 or IOTA I420-EM-A. INTG 1300 Super Emergency battery pack with integral test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B84CG-2-6 or IOTA I420-EMA-R.

Bodine B84CG-2-6 lamp type (4-pin) part number

IOTA I420-EMA-R lumens 1 lamp

GE: F13DBX, SYLVANIA: CF13DD/E

700 N/A

GE: F13TBX, SYLVANIA: CF13DT/E

700 N/A

GE: F18DBX, SYLVANIA: CF18DD/E

900 N/A

GE: F18TBX, SYLVANIA: CF18DT/E/IN

900 N/A

GE: F26DBX, SYLVANIA: CF26DD/E

700 N/A

GE: F26TBX, SYLVANIA: CF26DT/E/IN

700 N/A

GE: F32TBX, SYLVANIA: CF32DT/E/IN

1250 N/A

GE: F42TBX, SYLVANIA: CF42DT/E/IN

1250 N/A

116

lumens

lamp type (4-pin) part number

2 lamps

1 lamp

GE: F13DBX, SYLVANIA: CF13DD/E GE: F13TBX, SYLVANIA: CF13DT/E GE: F18DBX, SYLVANIA: CF18DD/E GE: F18TBX, SYLVANIA: CF18DT/E/IN GE: F26DBX, SYLVANIA: CF26DD/E GE: F26TBX, SYLVANIA: CF26DT/E/IN GE: F32TBX, SYLVANIA: CF32DT/E/IN GE: F42TBX, SYLVANIA: CF42DT/E/IN GE: F57TBX, SYLVANIA: CF57DT/E/IN GE: F70TBX, SYLVANIA: CF70DT/E/IN

2 lamps

600 675 600 675 600 950 600 950 725 1200 725 1200 1050 1250 1300 N/A 1160 N/A 1200 N/A

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333


emergency battery pack description, part number and lumen output ICE-1300 Extended Temperature Super Emergency battery pack(-20ºC to +50ºC) with remote test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B4CF-2 or IOTA ICE-420-EM-A.

Bodine B4CF-2

ICE-420-EM-A

lamp type (4-pin) part number

lumens 1 lamp

lamp type (4-pin) part number

2 lamps

GE: F13DBX, SYLVANIA: CF13DD/E

700 N/A

GE: F13TBX, SYLVANIA: CF13DT/E

700 N/A

GE: F18DBX, SYLVANIA: CF18DD/E

900 N/A

GE: F18TBX, SYLVANIA: CF18DT/E/IN

900 N/A

GE: F26DBX, SYLVANIA: CF26DD/

700 N/A

GE: F26TBX, SYLVANIA: CF26DT/E/IN

700 N/A

GE: F32TBX, SYLVANIA: CF32DT/E/IN

1250 N/A

GE: F42TBX, SYLVANIA: CF42DT/E/IN

1250 N/A

lumens 1 lamp

GE: F13DBX, SYLVANIA: CF13DD/E GE: F13TBX, SYLVANIA: CF13DT/E GE: F18DBX, SYLVANIA: CF18DD/E GE: F18TBX, SYLVANIA: CF18DT/E/IN GE: F26DBX, SYLVANIA: CF26DD/E GE: F26TBX, SYLVANIA: CF26DT/E/IN GE: F32TBX, SYLVANIA: CF32DT/E/IN GE: F42TBX, SYLVANIA: CF42DT/E/IN GE: F57TBX, SYLVANIA: CF57DT/E/I GE: F70TBX, SYLVANIA: CF70DT/E/IN

2 lamps

600 675 600 675 600 950 600 950 725 1200 725 1200 1050 1250 1300 N/A 1160 N/A 1200 N/A

Bodine B94C-2-2

IOTA I42EM-J

When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG

IOTA I42EM-R-J

www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333

117


product index catalog number page

catalog number page

catalog number page

1101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

4604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

6518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

4607 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

6519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

4614 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

6521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

4615 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

6522 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6523 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6524 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6526 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6527 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

1115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

6106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6705 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6706 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6707 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6708 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

1513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6709 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

1514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6710 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

1515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

6116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6711 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87

6117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87

6118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87

6119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6714 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6717 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6718 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6719 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

4109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

6721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88

6501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

6723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

6724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

6725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

6726 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

6727 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

4116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87

6508 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87

6509 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

4121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

8104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

8106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88

6513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

4125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88

6514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

4126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88

6515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

4127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88

6516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

4601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

6517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

8112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

118

www.iuseelite.com • www.maxilume.com


product index catalog number page

catalog number page

catalog number page

8113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8708 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B473 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

8114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8709 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B4CF-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

8115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8710 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B4PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

8116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8711 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B4PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

8117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

8714 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8717 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8718 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8719 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B535 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

8722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B541 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

8723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B542 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

8724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B565 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

8503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

8725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B5PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

8504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

8726 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B5PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

8505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

8727 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

B5PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

8506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

2W-T418-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16

B5PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

8507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

2W-T426-120-1-S . . . . . . . . . . . . . . . . . . . . . . 16

B601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

8508 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

2W-T426-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16

B605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

8509 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

2W-T432-120-1-S . . . . . . . . . . . . . . . . . . . . . . 16

B620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

2W-T432-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16

B6PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

8511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

AF632 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

B6PLIC-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

8512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

AF640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

B6PLIC-32-E . . . . . . . . . . . . . . . . . . . . . . . . . . 104

8513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

AYF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B6PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

8514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

AYF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . 20

B6PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

8515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

B36PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

B6PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

8516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

B36PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . 111

B701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

B391 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

B702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

B397 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

B703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

B401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B705 . . . . . . . . . . . . . . . . . . . . . . . . . . . 106, 108

8522 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B706 . . . . . . . . . . . . . . . . . . . . . . . . . . . 106, 108

8523 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B707 . . . . . . . . . . . . . . . . . . . . . . . . . . 107, 1083

8524 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B437 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8526 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B438 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

8527 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B439 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

B723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 B724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B444 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

B725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B451 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

B729 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

8703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B452 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

B731 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

8704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B454 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B735 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

8705 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B455 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

8706 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B462 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B737 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

8707 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B471 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

B741 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

www.iuseelite.com • www.maxilume.com

119


product index catalog number page

catalog number page

catalog number page

B742 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

FDB-T442-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15

MSCF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . 21

B743 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

FDB-T442-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15

NF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B751 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

GRX-310 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

NF-10-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B752 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

GRX-IT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

NF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B753 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

GRX-IT-WH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

NF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B754 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

HH10PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

NFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

B755 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

HH4SQPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

NTF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B756 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

HH6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

NTF-10-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B757 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HH6PLIC-AT . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

NTF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B758 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HH8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

NTF-103-P-277 . . . . . . . . . . . . . . . . . . . . . . . . 20

B759 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HHJ6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

NTFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

B760 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HHJ8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

QSG-P120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

B780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HHR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

RTA-RX-F . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22

B781 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HHR8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

RTA-TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

B782 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HS6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

RTA-WX . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22

B785 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HS8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

RTZ-TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

B787 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HV10PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

SF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B788 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HV4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

SF-10P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B789 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HV4PLIC-AT . . . . . . . . . . . . . . . . . . . . . . . . 29, 86

SF-12P-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B796 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

HV6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

SF-12P-277-3 . . . . . . . . . . . . . . . . . . . . . . . . . . 20

B84CG-2-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

HV8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

SFTU-5A3P . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

B94C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

HVJ4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

SPS-4IT-RP . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22

BDL94C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

HVJ6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

SPSF-6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

BHHR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

HVJ8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

SPSF-6A-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 21

BHVR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

HVR4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

SPSF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

DVF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

HVR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

SPSF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . . 21

DVF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . 20

HVR8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

SPSFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

DVFTU-5A3P . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

HW6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

VF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

DVSCF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

HW8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

VTF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

DVSCF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . 20

I-42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

EMG 1300 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

I420-EMA-R . . . . . . . . . . . . . . . . . . . . . . . . . . 114

EMG 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

I-42-DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

EMG-D 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

ICE-420-EM-A . . . . . . . . . . . . . . . . . . . . . . . . . 115

FDB-T418-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14

INTG 1300 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

FDB-T418-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14

INTG 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

FDB-T418-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15

INTG-D 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

FDB-T418-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15

LXF-103PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

FDB-T426-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14

LXF-103PL-277 . . . . . . . . . . . . . . . . . . . . . . . . 20

FDB-T426-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14

MAF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T426-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15

MAF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T426-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15

MA-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T432-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14

MA-R-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T432-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14

MSCA6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

FDB-T432-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15

MSCA8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

FDB-T432-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15

MSC-AD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T442-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14

MSC-AD-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 21

FDB-T442-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14

MSCF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

120

www.iuseelite.com • www.maxilume.com


sales agreement, terms and conditions General ACCEPTANCE/GOVERNING TERMS: These Terms and Conditions of Sale (“Agreement”) shall apply to all sales of products by Elite Lighting Inc., a corporation of the State of California. As used in these Terms and Conditions of Sale, “we” and “our” shall refer to Elite Lighting. Unless otherwise specifically agreed in writing by an authorized representative of Elite Lighting, any different or additional terms and conditions proposed by any customer in a purchase order, response to a quotation, or other proposal are hereby rejected by Elite Lighting and shall not be incorporated into the agreement for sale of Elite Lighting products. Customer’s assent to these Terms and Conditions of Sale shall be conclusively presumed from customer’s ordering products quoted by Elite Lighting, customer’s failure to object in writing to these Terms and Conditions of Sale, and/or customer’s acceptance of all or part of any products ordered. If Elite Lighting is found to have acknowledged customer’s order or proposal, and such acknowledgement constitutes an acceptance of an offer , such acceptance is expressly made conditional on customer’s assent solely to these Terms and Conditions of Sale, which shall form part of the acknowledgement, and acceptance by customer of any products shall be deemed to constitute such assent. If any quotation or other document of Elite Lighting is deemed to constitute an offer to customer, customer’s acceptance of such offer is limited to these Terms and Conditions of Sale.

Elite Lighting in writing and received prior to shipment of the order. Verbal order cancellations will not be

TERMS OF PAYMENT Terms Terms of payment for all of Elite Lighting products are as follows: All invoices must be paid within 30 days of invoice date. An additional fee of 2% per month or the highest lawful rate under applicable state law will be charged by Elite Lighting on all invoices which are past due. Should it be necessary for Elite Lighting to institute formal collection proceedings to collect any past due amounts from customer, Elite Lighting shall be entitled to recover its attorney’s fees and other costs associated with the proceedings. Notwithstanding the acceptance of any order by Elite Lighting, we reserve the right not to ship material to any customer not paying in accordance with our terms or who, in the sole opinion of Elite Lighting, may be unable to meet its payment obligations to Elite Lighting.

STANDARD PACKAGE POLICY AND/OR “BROKEN CARTON” CHARGE Elite Lighting will ship the order as written, but it will apply a broken carton charge of $5.00 to each catalog number so ordered which is not in box quantity.

FREIGHT TERMS Freight will be prepaid and allowed by Elite Lighting on any order totaling $2,000 or more within the limits of the continental United States. Orders not qualified for prepaid freight will be shipped with transportation charges prepaid by Elite Lighting and added to customer’s account, unless other method is requested by the customer. Partial shipments will be made at the discretion of the customer, provided the customer pays excess freight. When Elite Lighting bears the cost of shipment, we reserve the right to ship all orders in one complete shipment. Partial shipments may be made at our discretion. Elite Lighting will not be responsible for storage charges or cartage charges beyond the destination address acknowledged by Elite Lighting. All shipments will be made via carrier selected by Elite Lighting reserves the right to choose origin of shipment and routing. DIRECT SHIPMENTS Elite Lighting reserves the right to refuse the request of any distributor to make direct shipments of products to any destination outside the regular or assigned sales and service area of the distributor. MERCHANDISE AND CLAIMS TERMS Unless otherwise noted, sales of Elite Lighting Products will be F.O.B. factory. Title and risk of loss to all products shall pass from Elite Lighting to our customers upon execution of a bill of lading or tender of freight to carrier’s agent or customer’s agent, whichever shall first occur. When shipments of Elite Lighting products are to be made via company truck, title and risk of loss to the products shall pass to our customers at time of delivery to the final destination or to the forwarding carrier. All claims for loss or damage in transit must be made by customer to both the carrier and Elite Lighting within 5 working days. DATE OF SHIPMENT Shipping dates are approximate and are based on conditions existing at the time of Elite Lighting’s receipt of customer’s firm order and full information. Elite Lighting will in good faith endeavor to ship by the estimated shipping date but it shall not be responsible for any delay or any damage arising there from. RETURN MERCHANDISE TERMS No merchandise shall be returned by the customer without prior written consent and authorization in the form of a Return Goods Authorization (RGA), which has been issued by Elite Lighting expressly for the merchandise to be returned. This RGA will be issued at the sole discretion of Elite Lighting and must be requested by the customer within 90 days of the original shipment date. Returned merchandise must be in its original sealed cartons. All returned merchandise must be in salable condition in order to qualify for credit. No special products, nonstocking products, custom-made products, outdated or modified versions of cataloged factory stocking items may be returned by the customer. Except for products considered by Elite Lighting to be defective in workmanship or materials, all returns will be subject to a minimum 35% handling and factory inspection charge, and a deduction will be made for the freight expense of the original shipment. Merchandise accepted for return must be shipped prepaid to the factory or other destination specified by Elite Lighting. ORDER CANCELLATION TERMS Elite Lighting will accept order cancellations from customers only if the cancellations are sent to

accepted. Cancellation charges shall be those costs incurred by Elite Lighting, but not less than 10% of the value of an order. All costs for warehousing and freight on orders cancelled after shipment and/or refused at destination will be charged to the customer. Elite Lighting reserves the right to impose on the customer an additional charge of 25% of the value of an order if the order is cancelled after it has been processed for shipment. MINIMUM ORDER CHARGE A service charge of $20.00 will be added to all original customer orders, which total less than $100.00 net. PRICING Prices are subject to change without notice. Elite Lighting will ship merchandise at prices prevailing at the time of shipment. Prices are exclusive of sales, use, excise or similar taxes unless otherwise noted.

SPECIFICATIONS Elite Lighting in no way, express or implied, accepts responsibility for voltage determination. Elite Lighting shall not be responsible for quotations of prices or specifications concerning non-catalogued products unless Elite Lighting confirms this to the customer in writing. Catalogued items are those listed in Elite Lighting’s current price sheets. Dimensions of fixtures color modifications are subject to change without notice. Unless specifically agreed by Elite Lighting in writing, we do not warrant compliance of our products with individual project specifications. ERRORS Typographical or clerical errors in quotation orders or acknowledgments are subject to correction. DIMENSIONS The dimensions in catalogs and price lists are normally accurate, but are not to be used for construction purposes. CHANGES IN PRODUCT DESIGN Elite Lighting reserves the right to change, discontinue or modify the design and construction of any of its products and to substitute material equal to or superior to that originally specified. Conditions of Sale WARRANTY AND OBLIGATIONS THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT BY WAY OF LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Elite Lighting warrants that products sold will, upon shipment, be free of defects of workmanship or material under normal and proper usage. Should any failure to conform to this warranty become apparent during the warranty period (in most cases three years after the date of shipment) Elite Lighting must be notified in writing. Elite Lighting is not responsible for labor costs in connection with the installation, removal or replacement of warranted products or for any consequential damages. Elite Lighting further reserves the right to refuse to honor the above warranty for any product(s) altered, improperly installed in application for which not intended. In no event and under no circumstances shall Elite Lighting be liable to the purchaser or to any other person for any indirect, special, consequential or incidental losses or damages including, without limitation, lost profits except to the extent that liability for personal injury or property damage may be imposed upon Elite Lighting by law. As used herein, the term “person” shall include, without limitation, any individual, sole proprietorship, partnership, corporation or other entity. This warranty does not apply to Elite Lighting products which have been altered or repaired outside of Elite Lighting’s factory or which have been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty also does not apply to products not manufactured by Elite Lighting. Elite Lighting manufactures neither fluorescent ballasts, photoelectric controls nor lamps. Any warranty regarding such components is made by the manufacturer of the components, and customer shall direct all claims to the component manufacturer. LIMITATION OF LIABILITY IN NO EVENT SHALL ELITE LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE) NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF ELITE LIGHTING FOR ANY CLAMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THIS AGREEMENT OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF THE PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF THE PRODUCTS. THIS LIMITATION OF LIABILITY SHALL APPLY TO ANY LIABILITY FOR DEFAULT UNDER OR IN CONNECTION WITH THE PRODUCTS, PARTS, OR SERVICES DELIVERED HEREUNDER WHETHER BASED ON WARRANTY, FAILURE OF OR DELAY IN DELIVERY, OR OTHERWISE.

www.iuseelite.com • www.maxilume.com

121


• Architectural Downlighting • Residential Downlighting • Exit & Emergency Lighting • Linia Cove Lighting System • Undercabinet Lighting • Track Lighting • Ropelighting • Step Light

The products shown in this catalog are covered by USA and international patents. Specifications are subject to change without notice. elite lighting reserves the right to make any changes in the design, construction and listing approval of the products listed in this catalog which may be required by law or by the rules of any regulatory body or at its discretion. All information within this catalog is accurate at time of printing. Dimensions and specifications are subject to change without prior notice. Not responsible for any typographical error. Some pictures provided by: Peter Brentlinger. Not all lighting products shown in the pictures are manufactured by Elite Lighting. Wattage and specifications maybe different for products supplied in Canada. © Copyright 2009. Elite Lighting. All Rights Reserved.

main office: Los Angeles, CA Tel: 1-323-888-1973 / 1-877-375-5555 Fax: 1-323-888-1977 / 1-877-375-3333 www.iuseelite.com •  www.maxilume.com

www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road, Coopersburg, PA 18036-1299 World Headquarters 1.610.282.3800 Barcelona I Beijing I Berlin I Chicago I Dubai I Hong Kong I London I Los Angeles I Madrid I Mexico City I New York I Paris I São Paulo I Shanghai I Singapore I Tokyo I Toronto Technical Support Center 1.800.523.9466 I Customer Service 1.888.LUTRON1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.