Save energy and enhance comfort Efficient, dimmable compact fluorescent fixtures
www.LUTRON.com
Lutron
A
Lutron® dimming ballasts in every Elite and Maxilume lighting fixture now
Elite and Maxilume Lighting are proud to announce our newest partnership with Lutron. We now offer a new full line of recessed lighting fixtures equipped with Lutron dimming ballasts for all your project needs. Elite and Maxilume Lighting with Lutron are energized by a relentless drive to promote the highest standards in the lighting industry with the best lighting products for all types of applications. With Elite or Maxilume, you can get the best-performing dimmable fixtures for a wide variety of applications including retail, hospitality, corporate, institutional and residential projects.
Lutron invented the world’s first electronic dimming ballast over 30 years ago. From that point forward, Lutron continues to lead the industry with innovative and energy-saving fluorescent dimming options. Lutron offers an extensive selection of ballasts and controls, providing complete fluorescent dimming systems. B
Lutron
www.LUTRON.com
Hi-lume®, world's only 100% to 1% dimming ballasts for T4 compact fluorescent lamps
Dimming compact fluorescent fixtures Dimming architectural compact fluorescent fixtures create an enticing ambiance and enhance comfort. Meanwhile, lower light levels use less current so you save energy as the lamps are dimmed. Our fixtures with Lutron dimming ballasts provide you with maximized performance of light output, minimized energy usage, prolonged lamp life and the compatibility with any Lutron dimming system.
The benefits of Lutron dimming ballasts Designed to meet the most demanding lighting requirements of any application, Lutron dimming ballasts are the best and the most efficient available. They provide continuous, flickfree dimming, and are 100% performance tested. They are manufactured with the highest level of quality, using longlasting components that are carefully selected.
Best-in-class service For the first time, we are proud to offer same-day shipping on the complete line of our architectural and residential downlights with Lutron dimming ballasts to meet your needs. We offer unparalleled customer service from both companies—having all your lighting needs and technical problems taken care of is just a phone call away.
www.LUTRON.com
Lutron
1
Lutron
®
| table of contents
Why dim fluorescent? Measured light vs. perceived light Dimming applications Lutron quality Hi-lume® 1 % dimming ballasts Compact SE™ 5 % 3-wire dimming ballasts Tu-Wire® 5 % 2-wire dimming ballasts Select your dimming ballasts Ballast case dimensions Fluorescent dimming controls Select your fluorescent dimming controls
3 4 5 6 8 10 12 14 17 18 20
How to use this selection guide: The Fluorescent Dimming Systems Selection Guide helps you: • Determine the dimming range required for your application • Choose the appropriate Lutron dimming ballast • Choose the appropriate Lutron fluorescent control
|
|
MAXILUME Elite Lighting table of contents Architectural Downlighting HH4SQPL 4" Square CFL Trims HV4PL HV4PLIC-AT HVR4PL HVJ4PL 4" Vertical CFL Trims HV6PL HVR6PL HVJ6PL BHVR6PL 6" Vertical CFL Trims HV8PL HVR8PL HVJ8PL 8" Vertical CFL Trims HV10PL 10" Vertical CFL Trims HS6PL 6" Horizontal Shallow Trims
2
Lutron
28 29 30 31 32 33 34 36 37 38 39 40 44 45 46 47 52 53 54 55
HH6PL HH6PLIC-AT BHHR6PL HHR6PL HHJ6PL 6" Horizontal CFL Trims HS8PL 8" Horizontal Shallow Trims HH8PL HHR8PL HHJ8PL 8" Horizontal CFL Trims HH10PL 10" Horizontal CFL Trims HW6PL HW8PL Sloped Ceiling Adapter
www.LUTRON.com
Residential Downlighting 58 59 60 61 62 63 68 69 72 73 74 75 80 81 82 83 84
HV4PLIC-AT 4" Vertical CFL Trims B4PL-E B4PLR-E 4" CFL Trims B5PLIC-E B5PLRIC-E B5PL-E B5PLR-E 5" CFL Trims B6PLIC-E B6PLRIC-E B6PL-E B6PLR-E B6PLIC-26 OR 32-E 6" CFL Trims B36PLIC-E B36PLRIC-E 6" Slope CFL Trims
88 89 92 93 94 96 97 98 99 101 102 103 104 105 106 107 112 113 114
EMERGENCY BATTERY PACK 116-117
Lutron
速
| why dim fluorescent?
The benefits of dimming Create the perfect ambiance Dimming creates a rich visual experience and adds flexibility to any room, providing the right lighting environment for a variety of activities.
Give employees greater personal control Allowing employees to set preferred light levels for specific tasks results in greater employee comfort and improved performance.
Save electricity and maintain lamp life Dimming saves electricity and reduces the demand on HVAC systems. Dimming fluorescent lighting instead of repeated switching helps to maintain expected long lamp life.
Combine lighting control strategies to enhance building performance Using occupancy/vacancy sensors, daylight sensors and automated time-based controls with fluorescent dimming helps manage the lighting in an entire building and further reduce electric demand.
Dimming fluorescent lights saves energy Fluorescent lighting uses much less power than incandescent lighting. In a typical installation, a 32 watt compact fluorescent lamp provides approximately the same light output as a 100 watt incandescent lamp.
As both sources are dimmed, fluorescent lamps continue to be a more energy efficient light source.
100 W
Power consumed by incandescent source
Power
80 Over 60 watts of power is saved per fixture by using fluorescent lamps
60 40
Power consumed by fluorescent source
20 0
0
20
40
60
80
100 %
Measured Light
www.LUTRON.com
Lutron
3
Lutron
速
| measured light vs. perceived light
The human eye responds to low light levels by enlarging the pupil, allowing more light to enter the eye. This response results in a difference between measured and perceived light levels.
A lamp that is dimmed to 10 % of its maximum measured light output is perceived as being dimmed to only 32 %. Likewise, a lamp dimmed to 1 % is perceived to be at 10 %.
1 % Architectural dimming 5 % High performance dimming 10 % Lighting management dimming 100 % 90 80 70 60
Measured Light
50 40 30 20 10 5 1 0
10
22
32
40
50
60
70
80
90 100 %
Perceived Light
Measured Light (%) Formula: Perceived Light (%) = 100 x 100 Source:
4
IESNA Lighting Handbook, 9th Edition, (New York: IESNA, 2000), 27-4.
Lutron
www.LUTRON.com
Lutron
®
| dimming applications 1% Architectural dimming
5% High performance dimming
Small meeting room
Conference room/Boardroom
•
Lecture hall
•
Patient room/Examination and treatment room
•
• • •
House of worship
•
Lobby Hotel guest room Residential (See page 30 for appropriate ballast types.)
•
Theater
•
Convention area
•
Restaurants
•
Air traffic control center
•
Industrial control room
•
Graphic art workstation
•
CAD/CAM workstation
•
Retail
•
Presentation spaces
•
Critical task spaces
•
Design example
At full brightness, the measured light in a space is 60 foot-candles. At the lowest dimmed level, 10 % perceived light is desired.
1 % measured light (0.6 fcd) is perceived as 10 % (desired result)
5 % measured light (3 fcd) is perceived as 22 % (2x brighter than desired)
www.LUTRON.com
Lutron
5
Lutron
ÂŽ
| quality
Components in a Hi-lume 1 % dimming ballast for compact fluorescent lamps
Thermal Foldback Lutron patented Thermal Foldback technology is included in high-power ballasts, and actively monitors the ballast temperature. When necessary, power delivery to the lamps is automatically reduced, or “folded back�, to regulate ballast temperature, with minimal impact on light output. Thermal Foldback is designed to activate only if the ballast is operated in the environment that exceeds the ballast temperature rating.
6
Lutron
www.LUTRON.com
This technology prevents premature ballast failure due to overheating. In a properly designed application, Thermal Foldback will not engage. Refer to Fluorescent Dimming Systems Technical Guide P/N 366-606 for information about proper installation and the calibration point.
Superior components Lutron ballasts are manufactured to the highest level of quality, using carefully selected components. Maximum ballast lifetime is achieved by using only long-life components with significant performance history. In many cases, Lutron works with component suppliers to design custom parts in order to improve overall ballast quality.
Additionally, Lutron uses only metal ballast enclosures, allowing for optimal heat transfer to the lighting fixture.
Failure Rate
Product Reliability Curve
Customer receives Lutron ballast
˚
Running ballasts 10 C Cooler Useful life
Low failure rate
Lutron test and burn-in
100 % Test Lutron® tests the performance of every ballast prior to shipment. This important step eliminates ballasts that do not meet specifications. 100 % Burn-in Lutron “burns in” every ballast prior to shipment. Defects due to faulty components are screened out in this process, resulting in a dramatic reduction of early failures in the field.
DOUBLES useful life
Lutron dimming ballasts are burned in prior to shipment, ensuring lower failure rate in the field. Running ballasts 10 ºC cooler can also double their useful life.
Time
Extending ballast lifetime All electronic ballasts use components with a finite lifetime. A major factor for ballast lifetime is operating temperature. For every 10 ºC reduction in ballast case temperature, the ballast lifetime will be doubled. Lutron dimming ballasts are designed to maximize ballast lifetime by operating at a lower temperature, either through design or fixture choice.
www.LUTRON.com
Lutron
7
Lutron
®
| 1 % architectural dimming Hi-lume
®
Experience the benefits of true full-range 100 % to 1 % compact fluorescent dimming. Designed to meet the most demanding lighting requirements and featuring the world’s only 100 % to 1 % dimming ballasts for T4 compact fluorescent lamps, Hi-lume ballasts enable you to provide the ideal visual environment for any application. Integrating Hi-lume 1 % technology into your designs affords you full control over the lighting in any space. For the complete listing of Hi-lume ballasts, please see pages 14-15.
Dims T4 triple-tube compact lamps
•
Slim-profile design–just 1" high
•
Color-keyed push-in connectors
•
Available with or without mounting studs
•
8
Lutron
www.LUTRON.com
|
Hi-lume® 1 %
Performance
Specifications
Continuous, flicker-free dimming from 100 % to 1 %
Architectural dimming from 100 % to 1 % relative light output
•
•
3-wire line voltage control for consistent fixture-to-fixture dimming
•
Lamps turn on at any dimmed level without flashing to full brightness
•
Low harmonic distortion
No visible flicker
•
Total Harmonic Distortion (THD) less than 10 %
•
Power factor greater than .95
•
Ballast factor greater than .95
•
•
Frequency of operation greater than 42 kHz
•
Miswire protection
•
Inaudible in 27 dBA ambient environment
•
100 % performance tested
•
Inrush current limiting circuitry built-in (maximum of 7 amps for 120 V and 3 amps at 277 V)
•
Ultra-quiet operation
•
Designed in the USA
•
Internal fusing
•
5-year warranty (limited) with field service commissioning (3-year warranty standard)
•
Minimum lamp starting temperature 10 °C (50 °F)
•
Maximum ballast case temperature 75 °C (167 °F)
•
3-wire control For the full offering of Hi-lume dimming ballast controls by Lutron®, please see pages 20-21.
Hot 120 / 277 VAC 60 Hz Feed
Control
Hot Dimmed Hot Neutral
Dimming Ballast
Neutral
www.LUTRON.com
Lutron
9
Lutron
®
| 5 % high performance dimming Compact SE
TM
For designs requiring the energy savings and aesthetic appeal of dimmed compact fluorescent lamps, Compact SE dimming ballasts are your solution. The Compact SE product family includes ballasts for nearly every type of compact fluorescent lamp. Compact SE dimming ballasts deliver high performance 100 % to 5 % dimming, making them ideal for use in a variety of applications. In addition, Compact SE ballasts are compatible with the full line of 3-wire controls by Lutron. For the complete listing of Compact SE ballasts, please see pages 14-15.
Dims T4 quad- and triple-tube compact lamps
•
Slim-profile design–just 1" high
•
Color-keyed push-in connectors
•
Available with or without mounting studs
•
10
Lutron
www.LUTRON.com
Compact SE
TM
Performance
|5%
Specifications
Continuous, flicker-free dimming from 10 % to 5 %
•
3-wire line voltage control for consistent fixture-to-fixture dimming
•
Lamps turn on at any dimmed level without flashing to full brightness
•
Low harmonic distortion
High performance dimming from 100 % to 5 % relative light output
•
No visible flicker
•
Total Harmonic Distortion (THD) less than 10 %
•
Power factor greater than .95
•
Ballast factor greater than .95
•
•
Frequency of operation greater than 42 kHz
•
Miswire protection
•
Inaudible in 27 dBA ambient environment
•
100 % performance tested
•
Inrush current limiting circuitry built-in (maximum of 7 amps for 120 V and 3 amps at 277 V)
•
Ultra-quiet operation
•
Designed in the USA
•
Internal fusing
•
5-year warranty (limited) with field service commissioning (3-year warranty standard)
•
Minimum lamp starting temperature 10 °C (50 °F)
•
Maximum ballast case temperature 75 °C (167 °F)
•
3-wire control For the full offering of Compact SE dimming ballast controls by Lutron®, please see pages 20-21.
Hot 120 / 277 VAC 60 Hz Feed
Control
Hot Dimmed Hot Neutral
Dimming Ballast
Neutral
www.LUTRON.com
Lutron
11
Lutron
®
| 5 % high performance dimming Tu-Wire
®
Retrofit applications can benefit from the ease of installation offered by Lutron Tu-Wire dimming ballasts. Tu-Wire ballasts offer high performance 100 % to 5 % dimming for linear and compact fluorescent lamps. Tu-Wire ballasts require only two wires (hot and neutral) for power and control. Lutron offers a wide range of compatible 2-wire controls, making Tu-Wire a perfect choice for many applications. Additionally, one-lamp T4 models have been designed to meet FCC Part 18 consumer requirements. For the complete listing of Tu-Wire ballasts, please see page 16.
Dims T4 quad- and triple-tube compact lamps
•
Color-keyed push-in connectors
•
Available with or without mounting studs
•
12
Lutron
www.LUTRON.com
|
Tu-Wire® 5 %
Performance
Specifications
Continuous, flicker-free dimming from 100 % to 5 %
•
High performance dimming from 100 % to 5 % relative light output
•
No visible flicker
2-wire line voltage control for retrofit applications
•
•
Total Harmonic Distortion (THD) less than 20 %
•
Lamps turn on at any dimmed level without flashing to full brightness
•
Low harmonic distortion
Power factor greater than .95
•
Ballast factor greater than .85
•
•
Frequency of operation greater than 42 kHz
•
One-lamp T4 models meet FCC Part 18 consumer requirements for residential use (FCC ID: JPZB001)
•
Inaudible in 27 dBA ambient environment
•
Inrush current limiting circuitry built-in (maximum of 7 amps inrush current per ballast)
•
100 % performance tested
•
Internal fusing
•
Ultra-quiet operation
•
Minimum lamp starting temperature 10 °C (50 °F)
•
Designed in the USA
•
5-year warranty (limited) with field service commissioning (3-year warranty standard)
•
Maximum ballast case temperature 75 °C (167 °F)
•
2-wire control For the full offering of Tu-Wire dimming ballast controls by Lutron®, please see page 22. Control Hot 120 VAC 60 Hz Feed
Dimmed Hot
Neutral
Dimming Ballast
Neutral www.LUTRON.com
Lutron
13
Lutron
®
|
Lamp Type T4 4-Pin Quad-Tube
Hi-lume and Compact SE 120 volt 3-wire dimming ballasts ®
Lamp Lamps Watts per Case (Length) Ballast Type1
1 % Dimming
5 % Dimming
Hi-lume®
Compact SETM
18 W
1 2
A3 B3
— —
FDB-T418-120-1-S FDB-T418-120-2-S
.20 .42
26 W
1 2
A3 B3
— —
FDB-T426-120-1-S FDB-T426-120-2-S
.26 .50
18 W
1 2
A3 B3
— —
FDB-T418-120-1-S FDB-T418-120-2-S
.20 .42
26 W
1 2
A3 B3
HL3-T426-120-1-S FDB-T426-120-1-S — FDB-T426-120-2-S
.26 .50
32 W
1 2
A3 B3
HL3-T432-120-1-S FDB-T432-120-1-S — FDB-T432-120-2-S
.31 .59
42 W
1 2
B3 B3
— —
.39 .67
1/2 in Dia T4 4-Pin Triple-Tube
For the latest model numbers: www.lutron.com/ballasts
™
1/2 in Dia
10 % Dimming
FDB-T442-120-1-S FDB-T442-120-2-S
Ballast Current2 – Amps
4 Pin Electronic Lamp & Lamp Base Identification
18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)
26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)
32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)
42W • LAMP BASE: GX24Q-4 • LAMP INFORMATION: CFTR42W/GX24Q-4- 42W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F42TBX/4P) (SYLVANIA- CF42DT/E/IN)
1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 120. 2 Mounting studs standard. Delete suffix -S if mounting studs not desired. 14
Lutron
www.LUTRON.com
Lutron
®
|
Lamp Type T4 4-Pin Quad-Tube
Hi-lume and Compact SE 277 volt 3-wire dimming ballasts ®
Lamp Lamps Watts per Case (Length) Ballast Type1
1 % Dimming
5 % Dimming
Hi-lume®
Compact SETM
18 W
1 2
A3 B3
— —
FDB-T418-277-1-S FDB-T418-277-2-S
.08 .17
26 W
1 2
A3 B3
— —
FDB-T426-277-1-S FDB-T426-277-2-S
.12 .21
18 W
1 2
A3 B3
— —
FDB-T418-277-1-S FDB-T418-277-2-S
.08 .17
26 W
1 2
A3 B3
HL3-T426-277-1-S FDB-T426-277-1-S — FDB-T426-277-2-S
.12 .21
32 W
1 2
A3 B3
HL3-T432-277-1-S FDB-T432-277-1-S — FDB-T432-277-2-S
.13 .24
42 W
1 2
B3 B3
— —
.16 .29
1/2 in Dia T4 4-Pin Triple-Tube
For the latest model numbers: www.lutron.com/ballasts
™
1/2 in Dia
10 % Dimming
FDB-T442-277-1-S FDB-T442-277-2-S
Ballast Current2 – Amps
4 Pin Electronic Lamp & Lamp Base Identification
18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)
26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)
32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)
42W • LAMP BASE: GX24Q-4 • LAMP INFORMATION: CFTR42W/GX24Q-4- 42W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F42TBX/4P) (SYLVANIA- CF42DT/E/IN)
1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 277. 2 Standard with terminals. Leaded options available. Please consult Lutron. www.LUTRON.com
Lutron
15
Lutron
®
|
Tu-Wire 120 volt 2-wire dimming ballasts Lamp Lamps Watts per Case (Length) Ballast Type1
Lamp Type T4 4-Pin Quad-Tube
5 % Dimming 1 % Dimming Tu-Wire
10 % Dimming
Ballast Current2 – Amps
18 W
2
B4
2W-T418-120-2-S
.41
26 W
1 2
A4 B4
2W-T426-120-1-S5 2W-T426-120-2-S
.27 .53
18 W
2
B4
2W-T418-120-2-S
.41
26 W
1 2
A4 B4
2W-T426-120-1-S5 2W-T426-120-2-S
.27 .53
32 W
1 2
A4 B4
2W-T432-120-1-S5 2W-T432-120-2-S
.33 .58
1/2 in Dia T4 4-Pin Triple-Tube
For the latest model numbers: www.lutron.com/ballasts
®
1/2 in Dia
4 Pin Electronic Lamp & Lamp Base Identification
18W • LAMP BASE: G24Q-2, GX24Q-2 • LAMP INFORMATION: CFQ18W/G24Q-2 - 18W CFL QUAD TUBE LAMP, CFTR18W/GX24Q-2- 18W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F18DBX/4P,F18TBX/4P) (SYLVANIA- CF18DD/E, CF18DT/E/IN)
26W • LAMP BASE: G24Q-3, GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFQ26W/G24Q-3 - 26W CFL QUAD TUBE LAMP, CFTR26W/GX24Q-3- 26W CFL TRIPLE TUBE • LAMP PART NUMBER: (GE- F26DBX/4P,F26TBX/4P) (SYLVANIA- CF26DD/E, CF26DT/E/IN)
32W • LAMP BASE: GX24Q-3, GX24Q-4 • LAMP INFORMATION: CFTR32W/GX24Q-3- 32W CFL TRIPLE TUBE LAMP • LAMP PART NUMBER: (GE- F32TBX/4P) (SYLVANIA- CF32DT/E/IN)
1 To calculate ballast input power, use the following formula: Watts = Ballast Current x 120. 2 Standard with terminals. Leaded options available. Please consult Lutron. 3 Mounting studs standard. Delete suffix -S if mounting studs not desired. 4 One-lamp T4 models meet FCC Part 18 consumer requirements for residential use (FCC ID: JPZB001).
16
Lutron
www.LUTRON.com
Lutron
速
| ballast case dimensions
A
8-32 Threaded Stud 0.29 in (.736 mm)
A F
G
B
C I
H E
B A
B
G
D
8-32 Threaded Stud 0.29 in (.736 mm) F
C I
H E
D
A B C D E F G H I
4.20 in (107 mm) 1.00 in (25 mm) 3.00 in (76 mm) 4.90 in (124 mm) 4.60 in (117 mm) C-C (mounting centers) 2.00 in (51 mm) 1.08 in (27 mm) 1.60 in (41 mm) 1.39 in (35 mm)
A B C D E F G H I
6.00 in (152 mm) 1.00 in (25 mm) 3.00 in (76 mm) 6.75 in (171mm) 6.50 in (165 mm) C-C (mounting centers) 2.00 in (51 mm) 1.16 in (29 mm) 1.60 in (41 mm) 1.39 in (35 mm)
Proper ballast mounting is critical in providing effective grounding and for managing ballast heat. Please refer to the Lutron速 Fluorescent Dimming Systems Technical Guide (P/N 366-606) for detailed information.
www.LUTRON.com
Lutron
17
Lutron
®
| fluorescent dimming controls
Wallbox dimmers1 Vierti® Combines style and simplicity in a remarkably innovative control
Lyneo® Lx The simple, clean lines of the dimmer and matching switch ensure a coordinated look for your project
Maestro® NEW! The digital fade dimmer that coordinates with Claro® and Satin Colors® wallplates
www.lutron.com/lyneo
www.lutron.com/ maestro
www.lutron.com/vierti
Nova Ta® Classic, thin-profile linear-slide dimmer www.lutron.com/ novat
Vareo® Elegant thin-profile TapSwitchTM dimmer www.lutron.com/ vareo
Nova® Contractor’s choice in linearslide dimmers
Wireless remote controls1
www.lutron.com/ nova
Diva® Designer dimmer that matches your paddle switches www.lutron.com/ diva
RadioTouch® Wireless control of multiple lighting zones via radio frequency
•
Occupancy/vacancy sensing, motorized shade and A/V equipment control optional
•
Ideal for retrofit applications
•
Skylark® Original designer-style slide dimmer www.lutron.com/ skylark
Ariadni® Dimmer that matches your toggle switches
www.lutron.com/radiotouch
www.lutron.com/ ariadni
1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1.
18
Lutron
www.LUTRON.com
Preset scene controls1
GRAFIK Eye® QS NEW!
Spacer System®
Light and shade control in one unit
•
Controls lights with an IR control
Large, backlit engravable buttons
•
Up to five preset scenes
Built-in astronomical time clock and energy savings indicator
•
Easy upgrade for enclosed offices and conference rooms
Direct connections to sensors and other devices
•
Dims multiple sources
• • •
•
Select models directly control EcoSystem® and Hi-lume® 3D ballasts without an interface
•
www.lutron.com/spacersystem
www.lutron.com/grafikeyeqs
GRAFIK Eye® Create and recall 4-16 room lighting scenes
•
Optional accessories for wireless infrared (IR) remote control, remote scene selection, and more
•
Controls multiple sources
•
www.lutron.com/grafikeye
QuantumTM Solution NEW! Whole-building light and energy management Controls electric lights and shades from a central location; configures, monitors, analyzes, and reports on the lights for an entire building or campus. And the Quantum Green GlanceTM demonstrates how much energy your building is saving. www.lutron.com/quantum
1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. www.LUTRON.com
Lutron
19
Lutron
| select your fluorescent dimming controls
®
3-wire controls for Hi-lume and Compact SE ballasts1 ®
Nova Ta® Thin Profile Slide-To-Off Dimmer
Description single pole single pole single pole, 3-way, preset single pole, 3-way, preset
Ballast Voltage 120 V 277 V 120 V 277 V
Control Model Number NTF-10NTF-10-277NTF-103PNTF-103P-277-
Control Capacity 16 A 8A 8A 6A
Nova® Standard Profile Slide-To-Off Dimmer
single pole single pole single pole, 3-way, preset single pole, 3-way, preset
120 V 277 V 120 V 277 V
NF-10NF-10-277NF-103PNF-103P-277-
16 A 8A 8A 6A
Vareo® TapswitchTM/ Preset Slide Dimmer
single pole, 3-way
120 V
VF-10-
8 A2, 3
Diva® Paddle Switch/ Preset Slide Dimmer
single pole, 3-way single pole, 3-way single pole, 3-way single pole, 3-way
120 V 277 V 120 V 277 V
8A 6A 8A 6A
Skylark® Rocker Switch/ Preset Slide Dimmer
single pole single pole single pole, 3-way single pole, 3-way
120 V 277 V 120 V 277 V
DVF-103P-4 DVF-103P-277-4 DVSCF-103P-5 DVSCF-103P277-5 SF-10PSF-12P-277SF-103PSF-12P-277-3-
Ariadni® Toggle Switch/ Preset Slide Dimmer
single pole, 3-way single pole, 3-way
120 V 277 V
AYF-103PAYF-103P-277-
8A 6A
Vierti® Single-Touch Lighting Control
single pole, multi-location
120/277 V VTF-6AM-
single pole, 3-way, preset single pole, 3-way, preset
120 V 277 V
Control Family
NEW!
™
Lyneo® Lx Push-button Preset Slide NEW! Dimmer
LXF-103PLLXF-103PL-277-
8A 6A 8A 6A
6 A3, 6
8A 6A
1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Not to exceed 20 Lutron 3-wire dimming ballasts. 3 Must be derated if ganged. 4 Gloss finish. 5 Satin finish. 6 Not to exceed 60 Lutron 3-wire dimming ballasts. 20
Lutron
www.LUTRON.com
NEW!
Control Family Maestro® Digital Fade Tap Dimmer
RadioTouch® Wireless Multi-Zone Control Spacer System® Wireless Preset Scene Control
NEW!
GRAFIK Eye® QS Light and Shade Control System GRAFIK Eye Multi-Scene Preset Control
Description single, multi-location2 single, multi-location2 single, multi-location3 single, multi-location3 companion dimmer2 companion dimmer2 companion dimmer3 companion dimmer3 controller wallbox transmitter tabletop transmitter single pole single pole multi-location multi-location remote control control unit remote control (optional)
NEW!
Control Model Number MAF-6AMMAF-6AM-277MSCF-6AMMSCF-6AM-277MA-RMA-R-277MSC-ADMSC-AD-277RTA-RX-FRTA-WX-6 RTA-TX-
SPSF-6ASPSF-6A-277SPSF-6AM-7 SPSF-6AM-277-7 SPS-4IT-RP 120 / 277 V QSG-_8P120 GRX-IT
120 V 277 V 120 V 277 V
control unit 120 / 277 V GRX-310_9 GRX-IT-WH remote control (optional)
GRAFIK centralized lighting 5000TM /6000® /7000 TM control Lighting Control System QuantumTM Whole-building light and energy management
Ballast Voltage 120 V 277 V 120 V 277 V 120 V 277 V 120 V 277 V 120 / 277 V
lighting hub Q-manager PC
Control Capacity 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 20 Ballasts/6 A4, 5 8.3 A 8.3 A 8.3 A 8.3 A 16 A
6 A5. 6 6 A5. 6 6 A5. 6 6 A5, 6 16 A per power module 16 A per power module
120 / 277 V Contact your Lutron® representative for details
Contact your Lutron representative for details www.lutron.com/quantum
1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Gloss finish. 3 Satin finish. 4 Not to exceed 20 Lutron 3-wire dimming ballasts. 5 Must be derated if ganged. 6 Wallbox transmitter may be powered by 120 or 277 V. . 7 Also requires SPS-AD- or SPS-AD-277- for multi-location dimming (10 maximum). 8 Insert 3, 4, or 6 (number of zones); requires power module PHPM-3F-DV-WH. 9 Insert 2, 3, 4, or 6 (number of zones); requires power module PHPM-3F-DV-WH.
www.LUTRON.com
Lutron
21
Lutron
®
| select your fluorescent dimming controls
2-wire controls for Tu-Wire ballasts1 ®
Description single pole
Ballast Voltage 120 V
Control Model Number NTFTU-5A-
Control Capacity 5 A2
Nova® Standard Profile Slide-To-Off Dimmer
single pole
120 V
NFTU-5A-
5 A2
Diva® Paddle Switch/ Preset Slide Dimmer
single pole, 3-way
120 V
DVFTU-5A3P-
5 A2
Skylark® Rocker Switch/ Preset Slide Dimmer
single pole, 3-way
120 V
SFTU-5A3P-
5 A2
RadioTouch® Wireless Multi-Zone Control
controller wallbox transmitter tabletop transmitter
120 V
RTA-RX-F-3 RTA-WX-4 RTA-TX-
16 A
Spacer System® Wireless Preset Scene Control
single pole remote control
120 V
SPSFTU-5ASPS-4IT-RP
5 A2
GRAFIK Eye® QS control unit remote control (optional) Light and Shade Control System
120/277/ 347 V
QSG-_5P120 GRX-IT
16 A per unit, 6.7 A per zone
GRAFIK Eye Multi-Scene Preset Control GRAFIK 5000TM /6000® /7000TM Lighting Control System
control unit remote control (optional)
120 V
GRX-310_6 GRX-IT
16 A per unit, 6.7 A per zone
centralized lighting control
120/277 V Contact your Lutron representative for details
Control Family Nova Ta® Thin Profile Slide-To-Off Dimmer
NEW!
1 Fluorescent dimming controls are not available for purchase through Elite Lighting. To purchase controls, please contact your local Lutron Sales representative or call 1-888-LUTRON-1. 2 Minimum capacity: 2 ballasts. Must be derated if ganged. 3 Requires FDI-FTU-16A-120 interface. 4 Wallbox transmitter may be powered by 120 or 277 V. 5 Insert 3, 4, or 6 (number of zones). 6 Insert 2, 3, 4, or 6 (number of zones). 22
Lutron
www.LUTRON.com
Lutron
®
| dimming ballast reference guide for ordering Use the following summary as a quick reference to determine which Lutron dimming ballast you need to order in each product section.
Hi-lume 1% dimming Lut-H (HIL-HL3) ®
Dims T4 triple-tube compact lamps
Models:
Available in 120 V and 277 V
HL3-T426-120 (or 277)-1-S (for 26 W)
For 1-lamp 26 W and 32 W fixtures
HL3-T432-120 (or 277)-1-S (for 32 W)
• • •
Compact SE 5% dimming Lut-H (FDB) TM
Dims T4 quad- and triple-tube compact lamps
Models for quadand triple-tube lamps:
Available in 120 V and 277 V
FDB-T418-120 (or 277)-1-S (for 18 W 1-lamp)
Available for 1- and 2-lamp 18 W and 26 W quad-tubes
FDB-T418-120 (or 277)-2-S (for 18 W 2-lamp)
•
• •
Available for 1- and 2-lamp 18, 26, 32 and 42 W triple-tube lamps
•
FDB-T426-120 (or 277)-1-S (for 26 W 1-lamp) FDB-T426-120 (or 277)-2-S (for 26 W 2-lamp) Models for triple-tube lamps only: FDB-T432-120 (or 277)-1-S (for 32 W 1-lamp) FDB-T432-120 (or 277)-2-S (for 32 W 2-lamp) FDB-T442-120 (or 277)-1-S (for 42 W 1-lamp) FDB-T442-120 (or 277)-2-S (for 42 W 1-lamp)
Tu-Wire 5% dimming Lut-H (Tu-Wire) ®
Dims T4 quad- and triple-tube compact lamps
Models for quadand triple-tube lamps:
Available in 120 V
2W-T418-120-2-S (for 18 W 2-lamp)
Available for 2-lamp 18 W, and 1- and 2-lamp 26 W quad-tubes
2W-T426-120-1-S (for 26 W 1-lamp)
•
• •
Available for 2-lamp 18 W, and 1- and 2-lamp 26 W and 32 W triple-tube lamps
2W-T426-120-2-S (for 26 W 2-lamp)
•
Models for triple-tube lamps only: 2W-T432-120-1-S (for 32 W 1-lamp) 2W-T432-120-2-S (for 32 W 2-lamp)
www.LUTRON.com
Lutron
23
no. 1 in recessed lighting
t a b l e
o f
c o n t e n t s
vertical architectural compact fluorescent downlighting
HV4PL . . . . . . . . . . . . . . . . 30 4” Vertical Architectural Compact Fluorescent Downlighting
HV6PL . . . . . . . . . . . . . . . . 36 6” Vertical Architectural Compact Fluorescent Downlighting
HV8PL . . . . . . . . . . . . . . . . 44 8” Vertical Architectural Compact Fluorescent Downlighting
HV4PLIC-AT . . . . . . . . . . . . 31 4” Vertical Architectural Compact Fluorescent IC Downlighting
HVR6PL . . . . . . . . . . . . . . . 37 6” Vertical Architectural Compact Fluorescent Remodel Downlighting
HVR8PL . . . . . . . . . . . . . . . 45 8” Vertical Architectural Compact Fluorescent Remodel Downlighting
HVR4PL . . . . . . . . . . . . . . . 32 4” Vertical Architectural Compact Fluorescent Remodel Downlighting
HVJ6PL . . . . . . . . . . . . . . . 38 6” Vertical Architectural Compact Fluorescent Retrofit Downlighting
HVJ8PL . . . . . . . . . . . . . . . 46 8” Vertical Architectural Compact Fluorescent Retrofit Downlighting
HVJ4PL . . . . . . . . . . . . . . . 33 4” Vertical Architectural Compact Fluorescent Retrofit Downlighting
BHVR6PL . . . . . . . . . . . . . . 39 6” Vertical Architectural Compact Fluorescent Downlighting
8” Vertical Trims . . . . . . . 47
4” Vertical Trims . . . . . . . 33
6” Vertical Trims . . . . . . . 40
HV10PL . . . . . . . . . . . . . . . 52 10” Vertical Architectural Compact Fluorescent Downlighting 10” Vertical Trims . . . . . . 53
horizontal architectural compact fluorescent downlighting
HH4SQPL . . . . . . . . . . . . . . 28 4” Square Architectural Compact Fluorescent Downlighting 4” Square Trims . . . . . . . . 29
HS6PL . . . . . . . . . . . . . . . . 54 6” Horizontal Architectural Compact Fluorescent Shallow Downlighting 6” Shallow Trims . . . . . . . 55
HS8PL . . . . . . . . . . . . . . . . 68 8” Horizontal Architectural Compact Fluorescent Shallow Downlighting 8” Shallow Trims . . . . . . . 69
HH6PL . . . . . . . . . . . . . . . . 58 6” Horizontal Architectural Compact Fluorescent Downlighting
HH8PL . . . . . . . . . . . . . . . . 72 8” Horizontal Architectural Compact Fluorescent Downlighting
HH6PLIC-AT . . . . . . . . . . . . 59 6” Horizontal Architectural Compact Fluorescent IC Downlighting
HHR8PL . . . . . . . . . . . . . . . 73 8” Horizontal Architectural Compact Fluorescent Remodel Downlighting
HH10PL . . . . . . . . . . . . . . . 80 10” Horizontal Architectural Compact Fluorescent Downlighting 10” Horizontal Trims . . . . 81
BHHR6PL . . . . . . . . . . . . . . 60 6” Horizontal Architectural Compact Fluorescent Downlighting HHR6PL . . . . . . . . . . . . . . . 61 6” Horizontal Architectural Compact Fluorescent Remodel Downlighting HHR6PL . . . . . . . . . . . . . . . 62 6” Horizontal Architectural Compact Fluorescent Retrofit Downlighting
HHR8PL . . . . . . . . . . . . . . . 74 8” Horizontal Architectural Compact Fluorescent Retrofit Downlighting 8” Horizontal Trims . . . . . 75
sloped ceiling adapter
MSCA Maxilume Sloped Ceiling Adapter MSCA6 (6”) . . . . . . . . . . . . . 84 MSCA8 (8”) . . . . . . . . . . . . . 84
6” Horizontal Trims . . . . . 63
24
www.iuseelite.com • www.maxilume.com
architectural lighting
t a b l e
o f
c o n t e n t s
architectural compact fluorescent lensed wall wash downlighting
HW6PL . . . . . . . . . . . . . . . 82 6” Architectural Compact Fluorescent Lensed Wall Wash Downlighting
HW8PL . . . . . . . . . . . . . . . 83 8” Architectural Compact Fluorescent Lensed Wall Wash Downlighting
compact fluorescent downlighting
HV4PLIC-AT . . . . . . . . . . . . 88 4” Vertical Architectural Compact Fluorescent IC Downlighting 4” Vertical Trims . . . . . . . 89 B4PL-E . . . . . . . . . . . . . . . . 92 4” Miniature Compact Fluorescent Non-IC Downlighting B4PLR-E . . . . . . . . . . . . . . 93 4” Miniature Compact Fluorescent Non-IC Remodel Downlighting 4” Compact Fluorescent Trims . . . . . . . . . . . . . . . . . 94
B5PLIC-E . . . . . . . . . . . . . . 96 5” Compact Fluorescent IC Downlighting
B6PLIC-E . . . . . . . . . . . . . 102 6” Compact Fluorescent IC Downlighting
B36PLIC-E . . . . . . . . . . . . 112 6” Compact Fluorescent Slope Ceiling IC Downlighting
B5PLRIC-E . . . . . . . . . . . . . 97 5” Compact Fluorescent IC Remodel Downlighting
B6PLRIC-E . . . . . . . . . . . . 103 6” Compact Fluorescent IC Remodel Downlighting
B36PLRIC-E . . . . . . . . . . . 113 6” Compact Fluorescent Slope Ceiling IC Remodel Downlighting
B5PL-E . . . . . . . . . . . . . . . . 98 5” Compact Fluorescent Non-IC Downlighting
B6PL-E . . . . . . . . . . . . . . . 104 6” Compact Fluorescent Non-IC Downlighting
6” Slope Trims . . . . . . . . 114
B5PLR-E . . . . . . . . . . . . . . 99 5” Compact Fluorescent Non-IC Remodel Downlighting
B6PLR-E . . . . . . . . . . . . . 105 6” Compact Fluorescent Non-IC Remodel Downlighting
5” Compact Fluorescent Trims . . . . . . . . . . . . . . . . 101
B6PLIC-26 or 32-E . . . . . 106 6” Double Wall Compact Fluorescent IC Downlighting 6” Compact Fluorescent Trims . . . . . . . . . . . . . . . . 107
emergency battery pack
bodine b94c-2 . . . . . . . . 117
www.iuseelite.com • www.maxilume.com
iota i42em-j . . . . . . . . . 117
iota i42em-r-j . . . . . . . 117
25
ARCHITECTURAL LIGHTING available in
4” , 6 ” , 8 ” , a n d 1 0 ” architectural downlighting & trims
1 2
3 4 5 6
26
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
ARCHITECTURAL LIGHTING
1
MOUNTING BRACKET Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 26”. Mounting brackets may be adjusted vertically from inside the housing.
2
LAMP HOLDER Die-formed aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
3
MOUNTING FRAME Die-formed construction for maximum heat dissipation and rust protection.
4
JUNCTION BOX/BALLAST UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5
LENS Choice of either tempered clear, frosted, fresnel or prismatic lens fastened with two torsion springs for easy re-lamping. UL and ETL listed for wet or damp location.
6
REFLECTOR .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
Available sloped ceiling adapter if required. • MSCA-6 • MSCA-8
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
27
hh4sqpl square fluorescent series 4” square fluorescent downlighting
A. Min. Height = 5-1/2” B. Trim Aperture = 4-1/2” c. Cut-out = 5-1/2” d. Trim Outside Dia. = 5-3/4” e. Width = 7-3/4” f. Length = 7-1/8” g. Max. Length = 10”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
4”
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation.
7. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location.
4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
Hh4sqPL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
hl3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Reflector
emg 750
4106-Reflector
cl
emg 1300
4604-Reflector with Prismatic Glass Lens
shz
emg-d-750
4614-Reflector with Frosted Glass Lens
wt
ice-1300
4615-Reflector with Tempered Clear Glass
w
4607-Wall Wash Reflector with Lens
mb
Other Options
Ring WH - Self-Flange White
REFLECTOR RING CL Clear WH Self-Flange White WT Wheat Standard on all trims MB Black W White SHZ Satin Haze
fuse rif
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: Hh4sqPL-1X18-FDB-T418-120-EMG 750-4106-CL-WH 28
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
4” square fluorescent trims 4601-CL
4604-CL
REFLECTOR
REFLECTOR w/ prismatic glass lens
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”
A = 3-1/8” B = 5-3/4” C = 4-5/8”
4614-CL
4615-CL
REFLECTOR w/ Frosted Glass Lens
REFLECTOR w/ tempered clear glass
4” REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”
A = 3-1/8” B = 5-3/4” C = 4-5/8”
4607-CL wall wash reflector with lens
REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh A = 3-1/8” B = 5-3/4” C = 4-5/8”
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
29
hV4pl fluorescent series 4” vertical fluorescent downlighting
A. Min. Height = 7-1/2” Max. Height =8-1/2” (See trim heights for details)
B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
4”
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HV4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
4101-Reflector
4114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
4102-Baffle Reflector
4115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
4103-Reflector/Fresnel Glass Lens
4116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
4104-Reflector/Prismatic Glass Lens
4117-Baffle/Prismatic Plastic Lens
w
frost
4105-Baffle/Fresnel Glass Lens
4118-Reflector/Tempered Clear Plastic
mb
4106-Baffle/Prismatic Glass Lens
4119-Baffle/Tempered Clear Plastic
fuse
4107-Wall Wash Reflector
4109-Deco Glass Ring
rif
4108-Crossblade Reflector
4110-Double Ring
4112-Baffle/Frosted Glass Lens
4111-Triple Ring
Other Options
4113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH 30
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hv4plic-at fluorescent series 4” vertical fluorescent ic downlighting
A. Min. Height = 7-3/4” B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 8” f. Length = 12-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
4”
HV4PLic-at - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
------
-------
-------
-------
-------
-------
------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
4101-Reflector
4114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
4102-Baffle Reflector
4115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
4103-Reflector/Fresnel Glass Lens
4116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
4104-Reflector/Prismatic Glass Lens
4117-Baffle/Prismatic Plastic Lens
w
frost
4105-Baffle/Fresnel Glass Lens
4118-Reflector/Tempered Clear Plastic
mb
4106-Baffle/Prismatic Glass Lens
4119-Baffle/Tempered Clear Plastic
fuse
4107-Wall Wash Reflector
4109-Deco Glass Ring
rif
4108-Crossblade Reflector
4110-Double Ring
4112-Baffle/Frosted Glass Lens
4111-Triple Ring
Other Options
4113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV4PLIc-at-1X18-FDB-T418-120-EMG 750-4101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
31
hVr4pl fluorescent series 4” vertical fluorescent remodel downlighting
A. Min. Height = 7-1/4” Max. Height =8-1/2” (See trim heights for details)
B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 7-1/2” f. Length = 11-5/8” g. Flange = 2-1/4” DESCRIPTION:
TRIMS:
Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
4”
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HVR4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
4101-Reflector
4114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
4102-Baffle Reflector
4115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
4103-Reflector/Fresnel Glass Lens
4116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
4104-Reflector/Prismatic Glass Lens
4117-Baffle/Prismatic Plastic Lens
w
frost
4105-Baffle/Fresnel Glass Lens
4118-Reflector/Tempered Clear Plastic
mb
4106-Baffle/Prismatic Glass Lens
4119-Baffle/Tempered Clear Plastic
fuse
4107-Wall Wash Reflector
4109-Deco Glass Ring
rif
4108-Crossblade Reflector
4110-Double Ring
4112-Baffle/Frosted Glass Lens
4111-Triple Ring
Other Options
4113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVR4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH 32
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hvj4pl fluorescent series 4” vertical fluorescent retrofit downlighting
A. Min. Height = 7-1/4” Max. Height =8-1/2” (See trim heights for details)
B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2”
universal n installatio
(frame not included)
DESCRIPTION:
TRIMS:
Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 4-3/8” aperture.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
4”
HVJ4PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
4101-Reflector
4114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
4102-Baffle Reflector
4115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
4103-Reflector/Fresnel Glass Lens
4116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
4104-Reflector/Prismatic Glass Lens
4117-Baffle/Prismatic Plastic Lens
w
frost
4105-Baffle/Fresnel Glass Lens
4118-Reflector/Tempered Clear Plastic
mb
4106-Baffle/Prismatic Glass Lens
4119-Baffle/Tempered Clear Plastic
fuse
4107-Wall Wash Reflector
4109-Deco Glass Ring
rif
4108-Crossblade Reflector
4110-Double Ring
4112-Baffle/Frosted Glass Lens
4111-Triple Ring
Other Options
4113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVJ4PL-1X18-FDB-T418-120-EMG 750-4101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
33
4” vertical fluorescent trims
4”
4101-CL
4102-WH-CL
4107-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
4103-CL
4105-P
4114-CL
REFLECTOR w/ fresnel glass lens
baffle w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
4116-CL
4117-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
4121-CL
4122-CL
4123-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
4118-WT reflector w/ tempered clear plastic
trim o. d.: 5-1/2” REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh
new
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
4127-CL
4109-CL
4110-CL
geo deco ring glass
deco glass reflector
double ring glass
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
RING finish: Wh, shz
RING finish: Wh
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
new
34
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
4” vertical fluorescent trims 4108-CL crossblade REFLECTOR
trim o. d.: 5-1/2” REFlector finish: CL, Wt, SHZ, w RING finish: Wh
4104-CL
4106-WH
REFLECTOR w/ prismatic glass lens
baffle w/ prismatic glass lens
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
4115-WT
4113-WH
baffle w/ frosted glass lens
reflector w/ tempered clear glass
baffle w/ tempered clear glass
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
baffle finish: wh, p
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
4112-WH
4119-WH baffle w/ tempered clear plastic
4”
trim o. d.: 5-1/2” baffle finish: wh, p RING finish: Wh
4124-CL
4125-CL
4126-CL
geo deco ring glass
central etched float glass
diffusing screen wall wash glass
new
new
new
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
4111-CL triple ring glass
REFlector finish: CL, Wt, MB, SHZ, w RING finish: Wh, shz GLASS finish: Blue, red, green, frost
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
35
hV6pl fluorescent series 6” vertical fluorescent downlighting
A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6”
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HV6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6101-Reflector
6114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6102-Baffle Reflector
6115-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
6103-Reflector/Fresnel Glass Lens
6116-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
6104-Reflector/Prismatic Glass Lens
6117-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
6105-Baffle/Fresnel Glass Lens
6118-Reflector/Tempered Clear Plastic
mb
intg-d-750
6106-Baffle/Prismatic Glass Lens
6119-Baffle/Tempered Clear Plastic
ice-1300
6107-Wall Wash Reflector
6109-Deco Glass Ring
Other Options
6108-Crossblade Reflector
6110-Double Ring
fuse
6112-Baffle/Frosted Glass Lens
6111-Triple Ring
rif
6113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH 36
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hvR6pl fluorescent series 6” vertical fluorescent remodel downlighting
A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 1-1/2”
DESCRIPTION:
TRIMS:
Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
6”
HV6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6101-Reflector
6114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6102-Baffle Reflector
6115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6103-Reflector/Fresnel Glass Lens
6116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6104-Reflector/Prismatic Glass Lens
6117-Baffle/Prismatic Plastic Lens
w
frost
6105-Baffle/Fresnel Glass Lens
6118-Reflector/Tempered Clear Plastic
mb
6106-Baffle/Prismatic Glass Lens
6119-Baffle/Tempered Clear Plastic
fuse
6107-Wall Wash Reflector
6109-Deco Glass Ring
rif
6108-Crossblade Reflector
6110-Double Ring
6112-Baffle/Frosted Glass Lens
6111-Triple Ring
Other Options
6113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVR6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
37
hVj6pl fluorescent series 6” vertical fluorescent retrofit downlighting
A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8”
universal n installatio
(frame not included)
DESCRIPTION: Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 6-3/4” aperture. 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing. 2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6”
TRIMS: 3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 4. GROVE BAFFLE - One-piece aluminum with concentric rings. 5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HVJ6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
6101-Reflector
6114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6102-Baffle Reflector
6115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6103-Reflector/Fresnel Glass Lens
6116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6104-Reflector/Prismatic Glass Lens
6117-Baffle/Prismatic Plastic Lens
w
frost
6105-Baffle/Fresnel Glass Lens
6118-Reflector/Tempered Clear Plastic
mb
6106-Baffle/Prismatic Glass Lens
6119-Baffle/Tempered Clear Plastic
fuse
6107-Wall Wash Reflector
6109-Deco Glass Ring
rif
6108-Crossblade Reflector
6110-Double Ring
6112-Baffle/Frosted Glass Lens
6111-Triple Ring
Other Options
6113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVJ6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH 38
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
bhvr6pl fluorescent series 6” vertical fluorescent downlighting
A. Min. Height = 8-1/8” Max. Height =9-1/4” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
6”
BHVR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6101-Reflector
6114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6102-Baffle Reflector
6115-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
6103-Reflector/Fresnel Glass Lens
6116-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
6104-Reflector/Prismatic Glass Lens
6117-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
6105-Baffle/Fresnel Glass Lens
6118-Reflector/Tempered Clear Plastic
mb
intg-d-750
6106-Baffle/Prismatic Glass Lens
6119-Baffle/Tempered Clear Plastic
ice-1300
6107-Wall Wash Reflector
6109-Deco Glass Ring
Other Options
6108-Crossblade Reflector
6110-Double Ring
fuse
6112-Baffle/Frosted Glass Lens
6111-Triple Ring
rif
6113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6109, 6110 MB Black SCH** Self-Flange Chrome and 6111. W White ** Only available on 6101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: BHVR6PL-1X18-FDB-T418-120-EMG 750-6101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
39
6” vertical fluorescent trims
6”
6108-CL
6101-CL
6102-WH-CL
6107-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
6103-CL
6105-P
6114-CL
6112-WH
REFLECTOR w/ fresnel glass lens
baffle w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
baffle w/ frosted glass lens
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6116-CL
6117-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
6118-WT
6119-WH
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
6121-CL
6122-CL
6123-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
new
6124-CL geo deco ring glass
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6127-CL
6109-CL
6110-CL
6111-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
RING finish: Wh
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
geo deco ring glass
new
40
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” vertical fluorescent trims 6104-CL
6106-WH
REFLECTOR w/ prismatic glass lens
baffle w/ prismatic glass lens
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
6115-WT
6113-WH
reflector w/ tempered clear glass
baffle w/ tempered clear glass
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
6”
6125-CL
6126-CL
central etched float glass
diffusing screen wall wash glass
new
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6101-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
41
photometric data hv6pl-1x13-e-6101cl / hvr6pl-1x13-e-6101cl / hvj6pl1x13-e-6101cl- / bhvr6pl-1x13-e-6101cl lamp: philips pl-c 13w/27/4p
lumens: 900
Candle Power Distribution (Candelas)
Zonal Lumens Summary Zone Lumens 0-300 261.65 0-400 393.43 0 0-60 581.48 0 0-90 610.98 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 610.98
test no.: lli 0205-10f
total luminaire efficiency: 67.9%
%Lamp 29.1 43.7 64.6 67.9 0 0 0 0 67.9
%Fixt 42.8 64.4 95.2 100 0 0 0 0 100
spacing criteria: 1.14
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
11021 4279 478 337 540
0-10 . . . . . . . . . . 32.28 10-20 . . . . . . . . . 100.8 20-30 . . . . . . . . . 128.57 30-40 . . . . . . . . . 131.78 40-50 . . . . . . . . . 55.76 50-60 . . . . . . . . . 24.88 60-70 . . . . . . . . . 2.94 70-80 . . . . . . . . . 1.68 80-90 . . . . . . . . . 0
Total Luminaire Efficiency = 67.9%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
26.0 11.6 6.5 4.2 2.9
8.9’ 13.3’ 17.8’ 22.2’ 26.7’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 81 81 81 81 1 76 74 71 69 2 71 66 63 60 3 66 60 56 52 4 61 55 50 46 5 57 50 45 41 6 53 46 40 37 7 50 42 37 33 8 47 39 34 30 9 44 36 31 27 10 41 33 28 25 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
79 79 79 79 74 72 70 68 69 65 62 59 64 59 55 52 60 54 49 46 56 49 44 41 52 45 40 37 49 41 36 33 46 38 33 30 43 35 31 27 40 33 28 25 RW - Wall Reflectance
75 69 63 57 52 48 44 40 37 35 32
72 67 61 56 51 47 43 39 37 34 32
69 64 59 54 49 45 42 39 36 33 31
68 61 54 48 43 38 35 31 28 26 24
75 68 60 54 48 44 40 36 33 30 28
75 66 58 51 45 40 36 33 30 27 25
72 65 59 53 47 43 39 36 33 30 28
72 64 57 50 45 40 36 33 30 27 25
69 63 57 51 47 42 38 35 32 30 28
69 62 55 49 44 40 36 32 30 27 25
hv6pl-1x18-e-6101cl / hvr6pl-1x18-e-6101cl / hvj6pl1x18-e-6101cl- / bhvr6pl-1x18-e-6101cl lamp: philips pl-c 18w/27/4p/ALTO Candle Power Distribution (Candelas)
lumens: 1250
Zone Lumens 0-300 363.43 0-400 546.47 0-600 807.67 0-900 848.65 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 848.65
6”
test no.: lli 0205-10F
total luminaire efficiency: 67.9%
Zonal Lumens Summary %Lamp 29.1 43.7 64.6 67.9 0 0 0 0 67.9
%Fixt 42.8 64.4 95.2 100 0 0 0 0 100
spacing criteria: 1.14
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
15309 5943 664 468 755
0-10 . . . . . . . . . . 44.83 10-20 . . . . . . . . . 140.01 20-30 . . . . . . . . . 178.58 30-40 . . . . . . . . . 183.05 40-50 . . . . . . . . . 183.75 50-60 . . . . . . . . . 77.45 60-70 . . . . . . . . . 34.55 70-80 . . . . . . . . . 4.08 80-90 . . . . . . . . . 2.35
Total Luminaire Efficiency = 67.9%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 96 Degrees
Distance to Plane
36.1 16.1 9.0 5.8 4.0
8.9’ 13.3’ 17.8’ 22.2’ 26.7’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
42
RC RW
R oom C av i t y R a t io
4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 81 81 81 81 1 76 74 71 69 2 71 66 63 60 3 66 60 56 52 4 61 55 50 46 5 57 50 45 41 6 53 46 40 37 7 50 42 37 33 8 47 39 34 30 9 44 36 31 27 10 41 33 28 25 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
79 79 79 79 74 72 70 68 69 65 62 59 64 59 55 52 60 54 49 46 56 49 44 41 52 45 40 37 49 41 36 33 46 38 33 30 43 35 31 27 40 33 28 25 RW - Wall Reflectance
75 69 63 57 52 48 44 40 37 35 32
72 67 61 56 51 47 43 39 37 34 32
69 64 59 54 49 45 42 39 36 33 31
68 61 54 48 43 38 35 31 28 26 24
75 68 60 54 48 44 40 36 33 30 28
75 66 58 51 45 40 36 33 30 27 25
72 65 59 53 47 43 39 36 33 30 28
72 64 57 50 45 40 36 33 30 27 25
Candela Tabulation 0 0 . . . . . . . . . 416.01 1 . . . . . . . . . 417.67 3 . . . . . . . . . 423.56 5 . . . . . . . . . 424.66 7 . . . . . . . . . 417.39 9 . . . . . . . . . 402.85 11 . . . . . . . . 384.67 13 . . . . . . . . 367.79 15 . . . . . . . . 352.76 17 . . . . . . . . 340.99 19.5 . . . . . . 324.51 22.5 . . . . . . 307.79 25.5 . . . . . . 296.3 29 . . . . . . . . 282.91 33 . . . . . . . . 262.77 37.5 . . . . . . 230.01 42.5 . . . . . . 182.29 47.5 . . . . . . 125.52 55 . . . . . . . . 48.47 65 . . . . . . . . 3.99 75 . . . . . . . . 1.72 85 . . . . . . . . 85 0.93 90 . . . . . . . . 0
69 63 57 51 47 42 38 35 32 30 28
69 62 55 49 44 40 36 32 30 27 25
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
Candela Tabulation 0 0 . . . . . . . . . 577.84 1 . . . . . . . . . 580.14 3 . . . . . . . . . 588.33 5 . . . . . . . . . 589.86 7 . . . . . . . . . 579.75 9 . . . . . . . . . 559.56 11 . . . . . . . . 534.3 13 . . . . . . . . 510.86 15 . . . . . . . . 489.99 17 . . . . . . . . 473.64 19.5 . . . . . . 450.74 22.5 . . . . . . 427.52 25.5 . . . . . . 411.56 29 . . . . . . . . 392.96 33 . . . . . . . . 364.98 37.5 . . . . . . 319.48 42.5 . . . . . . 253.21 47.5 . . . . . . 174.34 55 . . . . . . . . 67.32 65 . . . . . . . . 5.54 75 . . . . . . . . 2.39 85 . . . . . . . . 1.3 90 . . . . . . . . 0
photometric data hv6pl-1x26-e-6101cl / hvr6pl-1x26-e-6101cl / hvj6pl1x26-e-6101cl- / bhvr6pl-1x26-e-6101cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 1800
Zonal Lumens Summary Zone Lumens 0-300 385.04 0-400 609.75 0 0-60 1008.38 0 0-90 1157.4 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1157.4
test no.: lli 1204-14d
total luminaire efficiency: 64.3%
%Lamp 21.4 33.9 56 64.3 0 0 0 0 64.3
%Fixt 33.3 52.7 87.1 100 0 0 0 0 100
spacing criteria: 1.44
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
23041 16979 6851 1017 1208
0-10 . . . . . . . . . . 35.48 10-20 . . . . . . . . . 139.65 20-30 . . . . . . . . . 209.91 30-40 . . . . . . . . . 224.71 40-50 . . . . . . . . . 251.2 50-60 . . . . . . . . . 147.42 60-70 . . . . . . . . . 113.82 70-80 . . . . . . . . . 30.88 80-90 . . . . . . . . . 4.32
Total Luminaire Efficiency = 64.3%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
27.0 12.0 6.8 4.3 3.0
11.0’ 16.5’ 22.0’ 27.5’ 33.0’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 108 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 77 77 77 77 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 20 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
75 75 75 75 69 67 65 63 64 59 56 53 59 53 49 45 54 47 43 39 50 43 38 34 46 39 34 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance
71 64 57 51 46 41 37 34 31 29 27
68 62 55 49 44 40 36 33 31 28 26
66 60 53 48 43 39 35 32 30 28 26
64 56 48 41 36 32 28 25 22 20 18
71 63 54 47 42 37 33 30 27 24 22
71 61 52 44 38 33 30 26 24 21 19
68 60 53 46 41 36 32 29 26 24 22
68 59 51 43 38 33 29 26 23 21 19
66 58 51 45 40 36 32 29 26 24 22
66 57 49 43 37 33 29 26 23 21 19
hv6pl-1x32-e-6101cl / hvr6pl-1x32-e-6101cl / hvj6pl1x32-e-6101cl- / bhvr6pl-1x32-e-6101cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 2400
Zone Lumens 0-300 513.19 0-400 812.61 0-600 1343.89 0-900 1541.5 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1541.5
test no.: lli 1204-14a
total luminaire efficiency: 64.2%
Zonal Lumens Summary %Lamp 21.4 33.9 56 64.2 0 0 0 0 64.2
%Fixt 33.3 52.7 87.2 100 0 0 0 0 100
spacing criteria: 1.44
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
30709 22578 9093 1220 1812
0-10 . . . . . . . . . . 47.3 10-20 . . . . . . . . . 186.17 20-30 . . . . . . . . . 279.72 30-40 . . . . . . . . . 299.42 40-50 . . . . . . . . . 334.82 50-60 . . . . . . . . . 196.46 60-70 . . . . . . . . . 151.29 70-80 . . . . . . . . . 40.65 80-90 . . . . . . . . . 5.68
Total Luminaire Efficiency = 64.2%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 108 Degrees
Distance to Plane
36.0 16.0 9.0 5.8 4.0
11.0’ 16.5’ 22.0’ 27.5’ 33.0’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
RC RW
R oom C av i t y R a t io
4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 76 76 76 76 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 19 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
75 75 75 75 69 67 65 63 64 59 56 53 58 53 49 45 54 47 43 39 50 43 38 34 46 39 33 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance
71 64 57 51 46 41 37 34 31 29 27
68 62 55 49 44 40 36 33 31 28 26
66 59 53 48 43 39 35 32 30 28 26
64 56 48 41 36 32 28 25 22 20 18
71 62 54 47 42 37 33 30 27 24 22
71 61 52 44 38 33 30 26 24 21 19
68 60 53 46 41 36 32 29 26 24 22
68 59 51 43 38 33 29 26 23 21 19
66 58 51 45 40 36 32 29 26 24 22
66 57 49 43 37 33 29 26 23 21 19
hv6pl-1x42-e-6101cl / hvr6pl-1x42-e-6101cl / hvj6pl1x42-e-6101cl- / bhvr6pl-1x42-e-6101cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 3200
Zone Lumens 0-300 684.53 0-400 1083.79 0 0-60 1792.05 0 0-90 2056.19 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2056.19
222
665
444
%Lamp 21.4 33.9 56 64.3 0 0 0 0 64.3
%Fixt 33.3 52.7 87.2 100 0 0 0 0 100
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
40946 30103 12207 1627 2416
0-10 . . . . . . . . . . 63.1 10-20 . . . . . . . . . 248.29 20-30 . . . . . . . . . 373.14 30-40 . . . . . . . . . 399.26 40-50 . . . . . . . . . 446.42 50-60 . . . . . . . . . 261.84 60-70 . . . . . . . . . 202.03 70-80 . . . . . . . . . 54.55 80-90 . . . . . . . . . 7.57
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 108 Degrees
Distance to Plane
48.1 21.4 12.0 7.7 5.3
11.0’ 16.5’ 22.0’ 27.5’ 33.0’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
RC RW
R oom Ca vi t y Ra t i o
4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 76 76 76 76 1 71 68 66 64 2 65 61 57 54 3 60 54 49 45 4 55 48 43 39 5 51 43 38 34 6 47 39 34 30 7 44 36 30 27 8 41 33 27 24 9 38 30 25 21 10 36 28 23 19 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
75 75 75 75 69 67 65 63 64 59 56 53 58 53 49 45 54 47 43 39 50 43 38 34 46 39 33 30 43 35 30 26 40 32 27 24 37 30 25 21 35 27 23 19 RW - Wall Reflectance
71 64 57 51 46 41 37 34 31 29 27
68 62 55 49 44 40 36 33 31 28 26
66 59 53 48 43 39 35 32 30 28 26
64 56 48 41 36 32 28 25 22 20 18
71 62 54 47 42 37 33 30 27 24 22
71 61 52 44 38 33 30 26 24 21 19
68 60 53 46 41 36 32 29 26 24 22
68 59 51 43 38 33 29 26 23 21 19
6”
spacing criteria: 1.44
Total Luminaire Efficiency = 64.3%
887
Candela Tabulation 0 0 . . . . . . . . . 576 1 . . . . . . . . . 577 3 . . . . . . . . . 587 5 . . . . . . . . . 603 7 . . . . . . . . . 620 9 . . . . . . . . . 636 11 . . . . . . . . 649 13 . . . . . . . . 657 15 . . . . . . . . 660 17 . . . . . . . . 663 19.5 . . . . . . 665 22.5 . . . . . . 662 25.5 . . . . . . 656 29 . . . . . . . . 634 33 . . . . . . . . 594 37.5 . . . . . . 535 42.5 . . . . . . 458 47.5 . . . . . . 367 55 . . . . . . . . 246 65 . . . . . . . . 73 75 . . . . . . . . 6 85 . . . . . . . . 3 90 . . . . . . . . 0
test no.: lli 1204-14e
total luminaire efficiency: 64.3%
Zonal Lumens Summary
Candela Tabulation 0 0 . . . . . . . . . 432 1 . . . . . . . . . 433 3 . . . . . . . . . 441 5 . . . . . . . . . 452 7 . . . . . . . . . 465 9 . . . . . . . . . 477 11 . . . . . . . . 487 13 . . . . . . . . 493 15 . . . . . . . . 495 17 . . . . . . . . 497 19.5 . . . . . . 499 22.5 . . . . . . 497 25.5 . . . . . . 492 29 . . . . . . . . 476 33 . . . . . . . . 446 37.5 . . . . . . 401 42.5 . . . . . . 344 47.5 . . . . . . 275 55 . . . . . . . . 185 65 . . . . . . . . 55 75 . . . . . . . . 5 85 . . . . . . . . 2 90 . . . . . . . . 0
66 58 51 45 40 36 32 29 26 24 22
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
66 57 49 43 37 33 29 26 23 21 19
Candela Tabulation 0 0 . . . . . . . . . 769 1 . . . . . . . . . 770 3 . . . . . . . . . 784 5 . . . . . . . . . 804 7 . . . . . . . . . 827 9 . . . . . . . . . 849 11 . . . . . . . . 866 13 . . . . . . . . 876 15 . . . . . . . . 880 17 . . . . . . . . 884 19.5 . . . . . . 887 22.5 . . . . . . 883 25.5 . . . . . . 875 29 . . . . . . . . 846 33 . . . . . . . . 792 37.5 . . . . . . 713 42.5 . . . . . . 611 47.5 . . . . . . 489 55 . . . . . . . . 328 65 . . . . . . . . 98 75 . . . . . . . . 8 85 . . . . . . . . 4 90 . . . . . . . . 0
43
hV8pl fluorescent series 8” vertical fluorescent downlighting
A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)
B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
8”
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HV8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
8101-Reflector
8114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8102-Baffle Reflector
8115-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
8103-Reflector/Fresnel Glass Lens
8116-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
8104-Reflector/Prismatic Glass Lens
8117-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
8105-Baffle/Fresnel Glass Lens
8118-Reflector/Tempered Clear Plastic
mb
intg-d-750
8106-Baffle/Prismatic Glass Lens
8119-Baffle/Tempered Clear Plastic
ice-1300
8107-Wall Wash Reflector
8109-Deco Glass Ring
Other Options
8108-Crossblade Reflector
8110-Double Ring
fuse
8112-Baffle/Frosted Glass Lens
8111-Triple Ring
rif
8113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH 44
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hvR8pl fluorescent series 8” vertical fluorescent remodel downlighting
A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)
B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 2-1/4” DESCRIPTION:
TRIMS:
Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
8”
HVR8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
8101-Reflector
8114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8102-Baffle Reflector
8115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
8103-Reflector/Fresnel Glass Lens
8116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
8104-Reflector/Prismatic Glass Lens
8117-Baffle/Prismatic Plastic Lens
w
frost
8105-Baffle/Fresnel Glass Lens
8118-Reflector/Tempered Clear Plastic
mb
8106-Baffle/Prismatic Glass Lens
8119-Baffle/Tempered Clear Plastic
fuse
8107-Wall Wash Reflector
8109-Deco Glass Ring
rif
8108-Crossblade Reflector
8110-Double Ring
8112-Baffle/Frosted Glass Lens
8111-Triple Ring
Other Options
8113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVR8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
45
hVJ8pl fluorescent series 8” vertical fluorescent retrofit downlighting
A. Min. Height = 8-7/8” Max. Height =9-7/8” (See trim heights for details)
B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8”
universal n installatio
(frame not included)
DESCRIPTION:
TRIMS:
Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 8-1/8” aperture.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
8”
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HVJ8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
8101-Reflector
8114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8102-Baffle Reflector
8115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
8103-Reflector/Fresnel Glass Lens
8116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
8104-Reflector/Prismatic Glass Lens
8117-Baffle/Prismatic Plastic Lens
w
frost
8105-Baffle/Fresnel Glass Lens
8118-Reflector/Tempered Clear Plastic
mb
8106-Baffle/Prismatic Glass Lens
8119-Baffle/Tempered Clear Plastic
fuse
8107-Wall Wash Reflector
8109-Deco Glass Ring
rif
8108-Crossblade Reflector
8110-Double Ring
8112-Baffle/Frosted Glass Lens
8111-Triple Ring
Other Options
8113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8109, 8110 MB Black SCH** Self-Flange Chrome and 8111. W White ** Only available on 8101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HVJ8PL-1X18-FDB-T418-120-EMG 750-8101-CL-WH 46
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” vertical fluorescent trims 8108-CL
8101-CL
8102-WH-CL
8107-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
8103-CL
8114-CL
8104-CL
8115-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 9-1/8”
8” 8112-WH
8105-P
8106-WH
8113-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8116-CL
8117-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
8118-WT
8119-WH
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8101-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
47
8” vertical fluorescent trims 8121-CL
8122-CL
8123-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
8124-CL geo deco ring glass
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8127-CL
8125-CL
8126-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
8” 8110-CL
8111-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
8109-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8101-WH-INTG 48
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” vertical fluorescent trims
8”
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
49
photometric data
8”
50
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
photometric data hv8pl-1x26-e-8101cl / hvr8pl-1x26-e-8101cl / hvj8pl1x26-e-6101cl- / bhvr8pl-1x26-e-8101cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 1800
Zonal Lumens Summary Zone Lumens 0-300 590.99 0-400 853.46 0 0-60 1229.7 0 0-90 1277.79 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1277.79
test no.: lli 0205-10e
total luminaire efficiency: 71%
%Lamp 32.8 47.4 68.3 71 0 0 0 0 71
%Fixt 46.3 66.8 96.2 100 0 0 0 0 100
spacing criteria: 1.06
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
13626 4086 491 381 654
0-10 . . . . . . . . . . 80.13 10-20 . . . . . . . . . 246.11 20-30 . . . . . . . . . 264.76 30-40 . . . . . . . . . 262.47 40-50 . . . . . . . . . 273.77 50-60 . . . . . . . . . 102.48 60-70 . . . . . . . . . 39.67 70-80 . . . . . . . . . 5.16 80-90 . . . . . . . . . 3.26
Total Luminaire Efficiency = 71%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
63.0 28.0 15.8 10.1 7.0
8.3’ 12.4’ 16.6’ 20.7’ 24.9’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 92 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance
79 73 66 61 56 51 47 44 40 38 35
76 70 64 59 54 50 46 43 40 37 35
72 68 62 57 53 49 45 42 39 36 34
71 64 57 51 46 42 38 34 31 29 27
79 71 64 57 52 47 43 39 36 33 31
79 70 61 54 49 44 39 36 33 30 28
76 69 62 56 51 46 42 39 36 33 31
76 68 60 54 48 43 39 36 33 30 28
72 67 60 55 50 45 42 38 35 33 30
72 66 59 53 47 43 39 35 33 30 28
hv8pl-1x32-e-8101cl / hvr8pl-1x32-e-8101cl / hvj8pl1x32-e-8101cl- / bhvr8pl-1x32-e-8101cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 2400
Zone Lumens 0-300 788.39 0-400 1138.52 0 0-60 1640.43 0 0-90 1704.58 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1704.58
test no.: lli 0205-10aa
total luminaire efficiency: 71%
Zonal Lumens Summary %Lamp 32.8 47.4 68.4 71 0 0 0 0 71
%Fixt 46.3 66.8 96.2 100 0 0 0 0 100
spacing criteria: 1.06
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
18177 5451 655 508 871
0-10 . . . . . . . . . . 106.89 10-20 . . . . . . . . . 328.3 20-30 . . . . . . . . . 353.19 30-40 . . . . . . . . . 350.13 40-50 . . . . . . . . . 365.2 50-60 . . . . . . . . . 136.7 60-70 . . . . . . . . . 52.92 70-80 . . . . . . . . . 6.89 80-90 . . . . . . . . . 4.35
Total Luminaire Efficiency = 71%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
84.0 37.3 21.0 13.4 9.3
8.3’ 12.4’ 16.6’ 20.7’ 24.9’
Distance Footcandles to Plane Beam Initial Nadir Spread BEAM DIA. MEASURED AT 10% OF NADIR F.C.
R oom C av i t y R a t io
Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance
79 73 66 61 56 51 47 44 40 38 35
76 70 64 59 54 50 46 43 40 37 35
72 68 62 57 53 49 45 42 39 36 34
71 64 57 51 46 42 38 34 31 29 27
79 71 64 57 52 47 43 39 36 33 31
79 70 61 54 49 44 39 36 33 30 28
76 69 62 56 51 46 42 39 36 33 31
76 68 60 54 48 43 39 36 33 30 28
72 67 60 55 50 45 42 38 35 33 30
72 66 59 53 47 43 39 35 33 30 28
hv8pl-1x42-e-8101cl / hvr8pl-1x42-e-8101cl / hvj8pl1x42-e-8101cl- / bhvr8pl-1x42-e-8101cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 3200
Zone Lumens 0-300 1050.79 0-400 1517.46 0 0-60 2186.42 0 0-90 2271.92 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2271.92
%Lamp 32.8 47.4 68.3 71 0 0 0 0 71
%Fixt 46.3 66.8 96.2 100 0 0 0 0 100
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Average 0-900
Zone Lumens
450 550 650 750 850
24227 7266 873 676 1162
0-10 . . . . . . . . . . 142.47 10-20 . . . . . . . . . 437.57 20-30 . . . . . . . . . 470.74 30-40 . . . . . . . . . 466.67 40-50 . . . . . . . . . 486.75 50-60 . . . . . . . . . 182.2 60-70 . . . . . . . . . 70.53 70-80 . . . . . . . . . 9.18 80-90 . . . . . . . . . 5.8
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF Beam Angle: 92 Degrees 8.3’ 12.4’ 16.6’ 20.7’ 24.9’
Distance to Plane
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
RC RW
R oom Ca vi t y Ra t i o
112.0 49.8 28.0 17.9 12.4
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 77 75 73 2 74 70 67 64 3 69 64 59 56 4 65 58 53 50 5 61 53 48 44 6 57 49 44 40 7 53 45 40 36 8 50 42 37 33 9 47 39 34 30 10 44 36 31 28 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 78 76 74 72 73 69 66 63 68 63 59 55 63 57 53 49 59 52 48 44 55 48 43 40 52 45 40 36 49 41 36 33 46 38 34 30 44 36 31 28 RW - Wall Reflectance
79 73 66 61 56 51 47 44 40 38 35
76 70 64 59 54 50 46 43 40 37 35
72 68 62 57 53 49 45 42 39 36 34
71 64 57 51 46 42 38 34 31 29 27
79 71 64 57 52 47 43 39 36 33 31
79 70 61 54 49 44 39 36 33 30 28
76 69 62 56 51 46 42 39 36 33 31
76 68 60 54 48 43 39 36 33 30 28
8”
spacing criteria: 1.06
Total Luminaire Efficiency = 71%
4’ 6’ 8’ 10’ 12’
Candela Tabulation 0 0 . . . . . . . . . 1344.47 1 . . . . . . . . . 1353.75 3 . . . . . . . . . 1386.3 5 . . . . . . . . . 1395.38 7 . . . . . . . . . 1388.28 9 . . . . . . . . . 1359.35 11 . . . . . . . . 1301.18 13 . . . . . . . . 1217.79 15 . . . . . . . . 1152.38 17 . . . . . . . . 1089.98 19.5 . . . . . . 996.48 22.5 . . . . . . 870.73 25.5 . . . . . . 777.58 29 . . . . . . . . 734.69 33 . . . . . . . . 696.71 37.5 . . . . . . 627.14 42.5 . . . . . . 518.76 47.5 . . . . . . 324.04 55 . . . . . . . . 102.51 65 . . . . . . . . 9.07 75 . . . . . . . . 4.31 85 . . . . . . . . 2.49 90 . . . . . . . . 0
test no.: lli 0205-10bb
total luminaire efficiency: 71%
Zonal Lumens Summary
Candela Tabulation 0 0 . . . . . . . . . 1007.84 1 . . . . . . . . . 1014.8 3 . . . . . . . . . 1039.2 5 . . . . . . . . . 1046.01 7 . . . . . . . . . 1040.69 9 . . . . . . . . . 1019 11 . . . . . . . . 975.4 13 . . . . . . . . 912.89 15 . . . . . . . . 863.85 17 . . . . . . . . 817.08 19.5 . . . . . . 746.99 22.5 . . . . . . 652.72 25.5 . . . . . . 582.89 29 . . . . . . . . 550.74 33 . . . . . . . . 522.27 37.5 . . . . . . 470.12 42.5 . . . . . . 388.88 47.5 . . . . . . 242.91 55 . . . . . . . . 76.84 65 . . . . . . . . 6.8 75 . . . . . . . . 3.23 85 . . . . . . . . 1.87 90 . . . . . . . . 0
72 67 60 55 50 45 42 38 35 33 30
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
72 66 59 53 47 43 39 35 33 30 28
Candela Tabulation 0 0 . . . . . . . . . 1791.95 1 . . . . . . . . . 1804.32 3 . . . . . . . . . 1847.71 5 . . . . . . . . . 1859.81 7 . . . . . . . . . 1850.35 9 . . . . . . . . . 1811.79 11 . . . . . . . . 1734.25 13 . . . . . . . . 1623.11 15 . . . . . . . . 1535.93 17 . . . . . . . . 1452.76 19.5 . . . . . . 1328.14 22.5 . . . . . . 1160.54 25.5 . . . . . . 1036.38 29 . . . . . . . . 979.22 33 . . . . . . . . 928.6 37.5 . . . . . . 835.88 42.5 . . . . . . 691.42 47.5 . . . . . . 431.89 55 . . . . . . . . 136.63 65 . . . . . . . . 12.09 75 . . . . . . . . 5.74 85 . . . . . . . . 3.32 90 . . . . . . . . 0
51
hV10pl fluorescent series 10” vertical fluorescent downlighting
A. Height = 15-1/4” B. Trim Aperture = 9-3/4” c. Cut-out = 10-1/2” d. Trim Outside Dia. = 10-3/4” e. Width = 17-1/2” f. Length = 16-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
10”
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HV10PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
1101-Reflector
wh
cl
blue
emg 1300
1102-Baffle Reflector
p
shz
red
intg 750
1103-Reflector/Fresnel Glass Lens
wt
green
intg 1300
1104-Reflector/Prismatic Glass Lens
w
frost
emg-d-750
1105-Baffle/Fresnel Glass Lens
mb
intg-d-750
1106-Baffle/Prismatic Glass Lens
ice-1300
1112-Baffle/Frosted Glass Lens
fuse
1114-Reflector/Frosted Glass Lens
BAFFLE REFLECTOR RING WH White CL Clear WH Self-Flange White P Black WT Wheat Standard on all trims MB Black SCH** Self-Flange Chrome W White ** Only available on 1101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only
rif
1115-Reflector/Tempered Glass Lens
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Other Options
1113-Baffle/Tempered Glass Lens
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV10PL-1X18-FDB-T418-120-EMG 750-1101-CL-WH 52
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
10” vertical fluorescent series
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 1101-WH-INTG
1101-CL
1102-WH-CL
REFLECTOR
baffle w/ REFLECTOR
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
RING finish: Wh, SCH, shz
reflector finish: CL
1103-CL
1104-CL
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ prismatic glass lens
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
1105-P
1106-WH
baffle w/ fresnel glass lens
baffle w/ prismatic glass lens
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
1112-WH
1113-WH
baffle w/ frosted glass lens
baffle w/ tempered clear glass
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
1114-CL
1115-WT
REFLECTOR w/ frosted glass lens
reflector w/ tempered clear glass
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
10”
53
hs6pl fluorescent series 6” horizontal fluorescent shallow downlighting
new A. Height = 4” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/8” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2”
4”
( SHALLOW )
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HS6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
6”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
6701-Reflector
6714-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6702-Baffle Reflector
6715-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6703-Reflector/Fresnel Glass Lens
6716-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6704-Reflector/Prismatic Glass Lens
6717-Baffle/Prismatic Plastic Lens
w
frost
6705-Baffle/Fresnel Glass Lens
6718-Reflector/Tempered Clear Plastic
mb
6706-Baffle/Prismatic Glass Lens
6719-Baffle/Tempered Clear Plastic
fuse
6707-Wall Wash Reflector
6709-Deco Glass Ring
rif
6708-Crossblade Reflector
6710-Double Ring
6712-Baffle/Frosted Glass Lens
6711-Triple Ring
Other Options
6713-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6709, 6710 MB Black SCH** Self-Flange Chrome and 6711. W White ** Only available on 6701 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HS6PL-1X18-FDB-T418-120-EMG 750-6701-CL-WH 54
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” horizontal fluorescent shallow trims 6708-CL
6701-CL
6702-WH-CL
6707-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
6703-CL
6714-CL
6704-CL
6715-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 7-3/8”
6” 6712-WH
6705-P
6706-WH
6713-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6716-CL
6717-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
6718-WT
6719-WH
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
55
6” horizontal fluorescent shallow trims
6”
56
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” horizontal fluorescent shallow trims 6721-CL
6722-CL
6723-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
6724-CL geo deco ring glass
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6727-CL
6725-CL
6726-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
6” 6710-CL
6711-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
6709-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
57
hh6pl fluorescent series 6” horizontal fluorescent downlighting
A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HH6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
6”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6501-Reflector
6514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6502-Baffle Reflector
6515-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
6503-Reflector/Fresnel Glass Lens
6516-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
6504-Reflector/Prismatic Glass Lens
6517-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
6505-Baffle/Fresnel Glass Lens
6518-Reflector/Tempered Clear Plastic
mb
intg-d-750
6506-Baffle/Prismatic Glass Lens
6519-Baffle/Tempered Clear Plastic
ice-1300
6507-Wall Wash Reflector
6509-Deco Glass Ring
Other Options
6508-Crossblade Reflector
6510-Double Ring
fuse
6512-Baffle/Frosted Glass Lens
6511-Triple Ring
rif
6513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HH6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 58
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hh6plic-at fluorescent series 6” horizontal fluorescent ic downlighting
A. Height = 7-3/4” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 10” f. Length = 12-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HH6PLIC-AT - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
6”
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6501-Reflector
6514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6502-Baffle Reflector
6515-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6503-Reflector/Fresnel Glass Lens
6516-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6504-Reflector/Prismatic Glass Lens
6517-Baffle/Prismatic Plastic Lens
w
frost
6505-Baffle/Fresnel Glass Lens
6518-Reflector/Tempered Clear Plastic
mb
6506-Baffle/Prismatic Glass Lens
6519-Baffle/Tempered Clear Plastic
fuse
6507-Wall Wash Reflector
6509-Deco Glass Ring
rif
6508-Crossblade Reflector
6510-Double Ring
6512-Baffle/Frosted Glass Lens
6511-Triple Ring
Other Options
6513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HH6PLIC-AT-1X18-FDB-T418-120-EMG 750-6501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
59
bhhr6pl fluorescent series 6” horizontal fluorescent downlighting
A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
BHHR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
6”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6501-Reflector
6514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6502-Baffle Reflector
6515-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
6503-Reflector/Fresnel Glass Lens
6516-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
6504-Reflector/Prismatic Glass Lens
6517-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
6505-Baffle/Fresnel Glass Lens
6518-Reflector/Tempered Clear Plastic
mb
intg-d-750
6506-Baffle/Prismatic Glass Lens
6519-Baffle/Tempered Clear Plastic
ice-1300
6507-Wall Wash Reflector
6509-Deco Glass Ring
Other Options
6508-Crossblade Reflector
6510-Double Ring
fuse
6512-Baffle/Frosted Glass Lens
6511-Triple Ring
rif
6513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: BHHR6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 60
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hhr6pl fluorescent series 6” horizontal fluorescent remodel downlighting
A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 7-1/2” f. Length = 12-1/2” g. Flange = 1-1/2”
DESCRIPTION:
TRIMS:
Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HHR6PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
6”
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
1X26-HL3-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
6501-Reflector
6514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6502-Baffle Reflector
6515-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6503-Reflector/Fresnel Glass Lens
6516-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6504-Reflector/Prismatic Glass Lens
6517-Baffle/Prismatic Plastic Lens
w
frost
6505-Baffle/Fresnel Glass Lens
6518-Reflector/Tempered Clear Plastic
mb
6506-Baffle/Prismatic Glass Lens
6519-Baffle/Tempered Clear Plastic
fuse
6507-Wall Wash Reflector
6509-Deco Glass Ring
rif
6508-Crossblade Reflector
6510-Double Ring
6512-Baffle/Frosted Glass Lens
6511-Triple Ring
Other Options
6513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HHR6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
61
hhj6pl fluorescent series 6” horizontal fluorescent retrofit downlighting
A. Min. Height = 5-3/8” Max. Height =5-1/2” (See trim heights for details)
B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8”
universal n installatio
(frame not included)
DESCRIPTION:
TRIMS:
Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 6-3/4” aperture.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HHJ6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
6”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
6501-Reflector
6514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
6502-Baffle Reflector
6515-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
6503-Reflector/Fresnel Glass Lens
6516-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
6504-Reflector/Prismatic Glass Lens
6517-Baffle/Prismatic Plastic Lens
w
frost
6505-Baffle/Fresnel Glass Lens
6518-Reflector/Tempered Clear Plastic
mb
6506-Baffle/Prismatic Glass Lens
6519-Baffle/Tempered Clear Plastic
fuse
6507-Wall Wash Reflector
6509-Deco Glass Ring
rif
6508-Crossblade Reflector
6510-Double Ring
6512-Baffle/Frosted Glass Lens
6511-Triple Ring
Other Options
6513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 6509, 6510 MB Black SCH** Self-Flange Chrome and 6511. W White ** Only available on 6501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HHJ6PL-1X18-FDB-T418-120-EMG 750-6501-CL-WH 62
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” horizontal fluorescent trims 6508-CL
6501-CL
6502-WH-CL
6507-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
6503-CL
6514-CL
6504-CL
6515-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 7-3/8”
6” 6512-WH
6505-P
6506-WH
6513-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6516-CL
6517-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
6518-WT
6519-WH
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
63
6” horizontal fluorescent trims 6521-CL
6522-CL
6523-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
6524-CL geo deco ring glass
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
6527-CL
6525-CL
6526-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
6” 6510-CL
6511-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 7-3/8”
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 7-3/8”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
6509-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG 64
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” horizontal fluorescent trims
6”
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
65
photometric data hh6pl-1x26-e-6501-cl / bhhr6pl-1x26-e-6501-cl / hhr6pl-1x26-e-6501-cl / hhj6pl-1x26-e-6501-cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 1800
Zonal Lumens Summary Zone Lumens 0-300 433.56 0-400 681.63 0 0-60 1042.61 0 0-90 1074.19 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1074.19
test no.: lli 0204-14f
total luminaire efficiency: 59.7%
%Lamp 24.1 37.9 57.9 59.7 0 0 0 0 59.7
Luminance Data (cd/sq.m)
%Fixt 40.4 63.5 97.1 100 0 0 0 0 100
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
45 550 650 750 850
23711 5323 623 610 1208
26429 3763 498 610 1208
25349 4130 623 610 1208
0
spacing criteria: 1.34
Zone Lumens 0-10 . . . . . . . . . . 42.39 10-20 . . . . . . . . . 154.75 20-30 . . . . . . . . . 236.41 30-40 . . . . . . . . . 248.07 40-50 . . . . . . . . . 262.61 50-60 . . . . . . . . . 98.37 60-70 . . . . . . . . . 24.22 70-80 . . . . . . . . . 4.08 80-90 . . . . . . . . . 3.28
Total Luminaire Efficiency = 59.7%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF
Distance to Plane
33.6 14.9 8.4 5.4 3.7
9.5’ 14.3’ 19.1’ 23.8’ 28.6’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
RC RW
80% 70% 50% 30% 10%
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
0 1 2 3 4 5
71 67 62 58 54 50
69 65 61 56 52 49
69 60 52 46 40 36
66 61 55 50 46 42
66 59 53 47 42 38
66 58 51 45 40 35
63 59 54 49 44 41
63 57 52 46 41 37
63 56 50 44 39 35
61 57 52 47 43 40
61 56 50 45 41 37
61 55 49 43 39 39
60 54 48 42 38 33
45 39 35 32 42 36 32 28 40 33 29 26 37 30 26 23 35 24 21 RW - 28 Wall Reflectance
38 35 32 30 28
34 31 28 26 24
31 28 26 23 21
37 34 32 29 27
34 31 28 26 24
31 28 25 23 21
36 33 31 29 27
33 30 28 25 23
31 28 25 23 21
30 27 24 22 20
71 65 58 53 48 43
71 63 55 49 44 39
71 61 53 46 40 36
6 46 40 35 32 7 43 36 32 29 8 40 33 29 26 9 38 31 26 23 10 - Ceiling 36 Cavity 28 Reflectance 24 21 RC
69 69 63 62 57 55 52 48 47 43 43 39
Candela Tabulation 0 0 . . . . . 537 . . . . . . 1 . . . . . 544 . . . . . . 3 . . . . . 558 . . . . . . 5 . . . . . 569 . . . . . . 7 . . . . . 580 . . . . . . 9 . . . . . 584 . . . . . . 11 . . . . 585 . . . . . . 13 . . . . 589 . . . . . . 15 . . . . 599 . . . . . . 17 . . . . 611 . . . . . . 19.5 . . . 626 . . . . . . 22.5 . . . 619 . . . . . . 25.5 . . . 632 . . . . . . 29 . . . . 624 . . . . . . 33 . . . . 595 . . . . . . 37.5 . . . 523 . . . . . . 42.5 . . . 378 . . . . . . 47.5 . . . 259 . . . . . . 55 . . . . 58 . . . . . . . 65 . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .
hh6pl-1x32-e-6501-cl / bhhr6pl-1x32-e-6501-cl / hhr6pl-1x32-e-6501-cl / hhj6pl-1x32-e-6501-cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 2400
Zone Lumens 0-300 578.5 0-400 909.41 0 0-60 1391.1 0 0-90 1433.09 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1433.09
6”
%Lamp 24.1 37.9 58 59.7 0 0 0 0 59.7
Luminance Data (cd/sq.m)
%Fixt 40.4 63.5 97.1 100 0 0 0 0 100
spacing criteria: 1.34
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
31640 7159 872 814 1812
35251 5048 747 610 1208
33762 5507 747 814 1812
Zone Lumens 0-10 . . . . . . . . . . 56.57 10-20 . . . . . . . . . 206.51 20-30 . . . . . . . . . 315.43 30-40 . . . . . . . . . 330.91 40-50 . . . . . . . . . 350.36 50-60 . . . . . . . . . 131.34 60-70 . . . . . . . . . 32.37 70-80 . . . . . . . . . 5.31 80-90 . . . . . . . . . 4.31
Total Luminaire Efficiency = 59.7%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF
Distance to Plane
44.8 19.9 11.2 7.2 5.0
9.5’ 14.3’ 19.1’ 23.8’ 28.6’
Initial Nadir Footcandles
Beam Spread
R oom C av i t y R a t io
Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
RC RW
80% 70% 50% 30% 10%
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
0 1 2 3 4 5
71 67 62 58 54 50
69 65 61 57 53 49
69 60 52 46 40 36
66 61 55 50 46 42
66 60 53 47 42 38
66 58 51 45 40 35
64 59 54 49 44 41
64 58 52 46 41 37
64 57 50 44 39 35
61 57 52 47 43 40
61 56 50 45 41 37
61 55 49 43 39 39
60 54 48 42 38 33
45 39 35 32 42 36 32 28 40 33 29 26 37 30 26 23 35 24 21 RW - 28 Wall Reflectance
38 35 32 30 28
34 31 28 26 24
31 28 26 23 21
37 34 32 29 27
34 31 28 26 24
31 28 25 23 21
36 33 31 29 27
33 30 28 25 23
31 28 25 23 21
30 27 24 22 20
71 65 58 53 48 44
71 63 55 49 44 39
71 61 53 46 40 36
6 46 40 35 32 7 43 36 32 29 8 41 33 29 26 9 38 31 26 23 10 - Ceiling 36 Cavity 28 Reflectance 24 21 RC
69 69 63 62 57 55 52 48 47 43 43 39
Candela Tabulation 0 45 0 . . . . . 716 . . . . . . 716 . . . . . . 1 . . . . . 726 . . . . . . 721 . . . . . . 3 . . . . . 744 . . . . . . 742 . . . . . . 5 . . . . . 759 . . . . . . 756 . . . . . . 7 . . . . . 774 . . . . . . 771 . . . . . . 9 . . . . . 779 . . . . . . 780 . . . . . . 11 . . . . 781 . . . . . . 781 . . . . . . 13 . . . . 785 . . . . . . 790 . . . . . . 15 . . . . 799 . . . . . . 814 . . . . . . 17 . . . . 815 . . . . . . 847 . . . . . . 19.5 . . . 836 . . . . . . 872 . . . . . . 22.5 . . . 826 . . . . . . 895 . . . . . . 25.5 . . . 843 . . . . . . 883 . . . . . . 29 . . . . 832 . . . . . . 811 . . . . . . 33 . . . . 794 . . . . . . 740 . . . . . . 37.5 . . . 698 . . . . . . 690 . . . . . . 42.5 . . . 505 . . . . . . 564 . . . . . . 47.5 . . . 345 . . . . . . 383 . . . . . . 55 . . . . 78 . . . . . . . 55 . . . . . . . 65 . . . . 7 . . . . . . . . 6 . . . . . . . . 75 . . . . 4 . . . . . . . . 4 . . . . . . . . 85 . . . . 3 . . . . . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .
hh6pl-1x42-e-6501-cl / bhhr6pl-1x42-e-6501-cl / hhr6pl-1x42-e-6501-cl / hhj6pl-1x42-e-6501-cl lamp: sylvania cf42dt/e/in/835 Candle Power Distribution (Candelas)
lumens: 3200
Zone Lumens 0-300 571.1 0-400 904.41 0-600 1392.7 0-900 1434.87 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1434.87
%Lamp 17.8 28.3 43.5 44.8 0 0 0 0 44.8
%Fixt 39.8 63 97.1 100 0 0 0 0 100
Luminance Data (cd/sq.m)
spacing criteria: 1.36 Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
34246 7159 623 610 1208
34730 6608 623 610 1208
33725 5966 747 610 1208
Zone Lumens 0-10 . . . . . . . . . . 54.55 10-20 . . . . . . . . . 204.11 20-30 . . . . . . . . . 312.43 30-40 . . . . . . . . . 333.31 40-50 . . . . . . . . . 355.83 50-60 . . . . . . . . . 132.46 60-70 . . . . . . . . . 34.23 70-80 . . . . . . . . . 4.7 80-90 . . . . . . . . . 3.24
Total Luminaire Efficiency = 44.8%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
43.3 19.3 10.8 6.9 4.8
9.9’ 14.8’ 19.8’ 24.7’ 29.6’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
66
R oom Ca vi t y Ra t i o
Beam Angle: 102 Degrees 4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 71 71 71 71 1 67 65 63 62 2 63 59 56 53 3 58 53 49 46 4 54 48 44 41 5 50 44 39 36 6 47 40 36 32 7 44 37 32 29 8 41 34 29 26 9 38 31 27 24 10 36 29 25 22 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
70 70 70 70 66 64 62 61 61 58 55 53 57 52 49 46 53 48 44 41 49 43 39 36 46 40 35 32 43 36 32 29 40 33 29 26 38 31 27 24 35 29 25 22 RW - Wall Reflectance
67 61 56 51 46 42 39 35 33 30 28
64 59 54 49 45 41 38 35 32 30 28
61 57 52 48 44 40 37 34 31 29 27
60 54 48 43 38 34 34 27 25 23 21
67 60 53 48 43 38 35 32 29 26 24
67 59 51 45 40 36 32 29 26 24 22
64 58 52 47 42 38 34 31 28 26 24
64 57 50 44 40 35 32 29 26 24 22
90 716 718 737 767 749 750 741 741 747 766 782 773 763 725 650 654 510 397 60 6 4 3 0
test no.: lli 0205-10g
total luminaire efficiency: 44.8%
Zonal Lumens Summary
90 537 538 552 558 561 562 555 555 560 574 586 580 572 543 487 490 383 298 45 5 3 2 0
test no.: lli 0204-14b
total luminaire efficiency: 59.7%
Zonal Lumens Summary
45 537 . . . . . 541 . . . . . 556 . . . . . 567 . . . . . 578 . . . . . 584 . . . . . 585 . . . . . 592 . . . . . 610 . . . . . 635 . . . . . 653 . . . . . 671 . . . . . 662 . . . . . 608 . . . . . 555 . . . . . 517 . . . . . 423 . . . . . 287 . . . . . 41 . . . . . . 4 . . . . . . . 3 . . . . . . . 2 . . . . . . . 0 . . . . . . .
61 56 51 46 41 37 34 31 28 26 24
61 55 49 44 39 35 35 28 26 23 22
Candela Tabulation 0 45 0 . . . . . 693 . . . . . . 693 . . . . . . 1 . . . . . 699 . . . . . . 698 . . . . . . 3 . . . . . 713 . . . . . . 710 . . . . . . 5 . . . . . 727 . . . . . . 723 . . . . . . 7 . . . . . 744 . . . . . . 738 . . . . . . 9 . . . . . 753 . . . . . . 751 . . . . . . 11 . . . . 761 . . . . . . 758 . . . . . . 13 . . . . 770 . . . . . . 773 . . . . . . 15 . . . . 785 . . . . . . 799 . . . . . . 17 . . . . 802 . . . . . . 825 . . . . . . 19.5 . . . 815 . . . . . . 851 . . . . . . 22.5 . . . 810 . . . . . . 886 . . . . . . 25.5 . . . 821 . . . . . . 844 . . . . . . 29 . . . . 806 . . . . . . 795 . . . . . . 33 . . . . 782 . . . . . . 750 . . . . . . 37.5 . . . 695 . . . . . . 692 . . . . . . 42.5 . . . 553 . . . . . . 551 . . . . . . 47.5 . . . 367 . . . . . . 382 . . . . . . 55 . . . . 78 . . . . . . . 72 . . . . . . . 65 . . . . 5 . . . . . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
90 693 693 703 713 718 720 717 714 728 751 771 765 744 709 649 664 518 388 65 6 3 2 0
photometric data hh6pl-2x13-e-6501-cl / bhhr6pl-2x13-e-6501-cl / hh6plic-2x13-e-6501-cl / hhr6pl-2x13-e-6501-cl / hhj6pl-2x13-e-6501-cl lamp: 2 philips pl-c 13w/27/4p lumens: 1800 (2 lamps) total luminaire efficiency: 42.1% Candle Power Distribution (Candelas)
Zonal Lumens Summary Zone Lumens 0-300 332.16 0-400 504.8 0 0-60 738.38 0 0-90 757.31 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 757.31
%Lamp 18.5 28 41 42.1 0 0 0 0 42.1
%Fixt 43.9 66.7 97.5 100 0 0 0 0 100
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
45 550 650 750 850
12768 918 374 407 604
15671 2478 374 407 604
16453 3120 374 407 604
0
Zone Lumens 0-10 . . . . . . . . . . 32.04 10-20 . . . . . . . . . 125.02 20-30 . . . . . . . . . 175.1 30-40 . . . . . . . . . 172.64 40-50 . . . . . . . . . 171.53 50-60 . . . . . . . . . 62.05 60-70 . . . . . . . . . 14.46 70-80 . . . . . . . . . 2.57 80-90 . . . . . . . . . 1.89
Total Luminaire Efficiency = 42.1%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
25.1 11.2 6.3 4.0 2.8
8.9’ 13.3’ 17.8’ 22.2’ 26.7’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 50 50 50 50 1 47 46 44 43 2 44 41 39 38 3 41 38 35 33 4 38 34 31 29 5 36 31 28 26 6 33 29 25 23 7 31 26 23 21 8 29 24 21 19 9 27 22 19 17 10 26 21 18 16 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
49 49 49 49 46 45 44 43 43 41 39 37 40 37 35 33 37 34 31 29 35 31 28 26 33 28 25 23 30 26 23 21 28 24 21 19 27 22 19 17 25 21 18 16 RW - Wall Reflectance
47 43 39 36 33 30 27 25 23 22 20
45 41 38 35 32 29 27 25 23 21 20
43 40 37 34 31 28 26 24 22 21 19
42 38 34 30 27 24 22 20 18 16 15
47 42 38 34 30 27 25 23 21 19 18
47 41 36 32 28 25 23 21 19 17 16
45 41 37 33 30 27 24 22 20 19 17
45 40 35 32 28 25 23 21 19 17 16
43 39 36 32 29 27 24 22 20 19 17
43 39 35 31 28 25 23 20 19 17 16
test no.: lli 0205-10k spacing criteria: 1.28 Candela Tabulation 0 45 0 . . . . . 402 . . . . . . 402 . . . . . . 1 . . . . . 404 . . . . . . 403 . . . . . . 3 . . . . . 405 . . . . . . 407 . . . . . . 5 . . . . . 398 . . . . . . 410 . . . . . . 7 . . . . . 401 . . . . . . 431 . . . . . . 9 . . . . . 390 . . . . . . 437 . . . . . . 11 . . . . 389 . . . . . . 453 . . . . . . 13 . . . . 393 . . . . . . 467 . . . . . . 15 . . . . 391 . . . . . . 471 . . . . . . 17 . . . . 388 . . . . . . 468 . . . . . . 19.5 . . . 382 . . . . . . 466 . . . . . . 22.5 . . . 363 . . . . . . 458 . . . . . . 25.5 . . . 354 . . . . . . 434 . . . . . . 29 . . . . 347 . . . . . . 401 . . . . . . 33 . . . . 343 . . . . . . 356 . . . . . . 37.5 . . . 289 . . . . . . 327 . . . . . . 42.5 . . . 197 . . . . . . 242 . . . . . . 47.5 . . . 146 . . . . . . 179 . . . . . . 55 . . . . 10 . . . . . . . 27 . . . . . . . 65 . . . . 3 . . . . . . . . 3 . . . . . . . . 75 . . . . 2 . . . . . . . . 2 . . . . . . . . 85 . . . . 1 . . . . . . . . 1 . . . . . . . . 90 . . . . 0 . . . . . . . . 0 . . . . . . . .
hh6pl-2x18-e-6501-cl / bhhr6pl-2x18-e-6501-cl / hh6plic-2x18-e-6501-cl / hhr6pl-2x18-e-6501-cl / hhj6pl-2x18-e-6501-cl lamp: 2 philips pl-c 18w/27/4p lumens: 2500 (2 lamps) total luminaire efficiency: 42% Candle Power Distribution (Candelas)
Zonal Lumens Summary Zone Lumens 0-300 461.29 0-400 701.12 0 0-60 1025.7 0 0-90 1051.02 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1051.02
%Lamp 18.5 28 41 42 0 0 0 0 42
%Fixt 43.9 66.7 97.6 100 0 0 0 0 100
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
17756 1193 498 407 604
21776 3488 498 407 604
22855 4314 498 407 604
Zone Lumens 0-10 . . . . . . . . . . 44.5 10-20 . . . . . . . . . 173.65 20-30 . . . . . . . . . 243.15 30-40 . . . . . . . . . 239.83 40-50 . . . . . . . . . 238.33 50-60 . . . . . . . . . 86.25 60-70 . . . . . . . . . 20.19 70-80 . . . . . . . . . 3.25 80-90 . . . . . . . . . 1.89
Total Luminaire Efficiency = 42%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
34.9 15.5 8.7 5.6 3.9
8.9’ 13.3’ 17.8’ 11.1’ 26.7’
Initial Nadir Footcandles
Beam Spread
R oom C av i t y R a t io
Beam Angle: 96 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 50 50 50 50 1 47 46 44 43 2 44 41 39 38 3 41 38 35 33 4 38 34 31 29 5 36 31 28 26 6 33 29 25 23 7 31 26 23 21 8 29 24 21 19 9 27 22 19 17 10 26 21 18 16 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
49 49 49 49 46 45 44 43 43 41 39 37 40 37 35 33 37 34 31 29 35 31 28 26 33 28 25 23 30 26 23 21 28 24 21 19 27 22 19 17 25 21 18 16 RW - Wall Reflectance
47 43 39 36 33 30 27 25 23 22 20
45 41 38 35 32 29 27 25 23 21 20
43 40 37 34 31 28 26 24 22 21 19
42 38 34 30 27 24 22 20 18 16 15
47 42 38 34 30 27 25 23 21 19 18
47 41 36 32 28 25 23 21 19 17 16
45 41 37 33 30 27 24 22 20 19 17
45 40 35 32 28 25 23 21 19 17 16
43 39 36 32 29 27 24 22 20 19 17
43 39 35 31 28 25 23 20 19 17 16
test no.: lli 0205-10u spacing criteria: 1.28 Candela Tabulation 0 0 . . . . . 558 . . . . . . 1 . . . . . 561 . . . . . . 3 . . . . . 563 . . . . . . 5 . . . . . 553 . . . . . . 7 . . . . . 557 . . . . . . 9 . . . . . 541 . . . . . . 11 . . . . 541 . . . . . . 13 . . . . 546 . . . . . . 15 . . . . 543 . . . . . . 17 . . . . 539 . . . . . . 19.5 . . . 530 . . . . . . 22.5 . . . 504 . . . . . . 25.5 . . . 492 . . . . . . 29 . . . . 481 . . . . . . 33 . . . . 476 . . . . . . 37.5 . . . 402 . . . . . . 42.5 . . . 274 . . . . . . 47.5 . . . 203 . . . . . . 55 . . . . 13 . . . . . . . 65 . . . . 4 . . . . . . . . 75 . . . . 2 . . . . . . . . 85 . . . . 1 . . . . . . . . 90 . . . . 0 . . . . . . . .
hh6pl-2x26-e-6501-cl / bhhr6pl-2x26-e-6501-cl / hh6plic-2x26-e-6501-cl / hhr6pl-2x26-e-6501-cl / hhj6pl-2x26-e-6501-cl lamp: 2 sylvania cf26dt/e/in/841 lumens: 3600 (2 lamps) total luminaire efficiency: 60% Candle Power Distribution (Candelas)
Zonal Lumens Summary Zone Lumens 0-300 896.48 0-400 1381.41 0-600 2097.34 0-900 2161.41 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 2161.41
%Lamp 24.9 38.4 58.3 60 0 0 0 0 60
%Fixt 41.5 63.9 97 100 0 0 0 0 100
Luminance Data (cd/sq.m)
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
39792 6149 1121 1017 1812
45636 8077 1246 1220 1812
51331 9912 1121 1017 2416
Zone Lumens 0-10 . . . . . . . . . . 87.26 10-20 . . . . . . . . . 339.05 20-30 . . . . . . . . . 470.17 30-40 . . . . . . . . . 484.93 40-50 . . . . . . . . . 520.01 50-60 . . . . . . . . . 195.92 60-70 . . . . . . . . . 50.57 70-80 . . . . . . . . . 7.62 80-90 . . . . . . . . . 5.88
Total Luminaire Efficiency = 60%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
65.9 29.3 16.5 10.5 7.3
9.2’ 13.8’ 18.4’ 23.0’ 27.6’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
R oom Ca vi t y Ra t i o
Beam Angle: 98 Degrees 4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 71 71 71 71 1 67 65 63 62 2 63 59 56 53 3 58 53 49 46 4 54 48 44 41 5 50 44 39 36 6 47 40 36 32 7 44 37 32 29 8 41 34 29 26 9 38 31 27 24 10 36 29 25 22 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
70 70 70 70 66 64 62 61 61 58 55 53 57 52 49 46 53 48 44 41 49 43 39 36 46 40 35 32 43 36 32 29 40 33 29 26 38 31 27 24 35 29 25 22 RW - Wall Reflectance
67 61 56 51 46 42 39 35 33 30 28
64 59 54 49 45 41 38 35 32 30 28
61 57 52 48 44 40 37 34 31 29 27
60 54 48 43 38 34 34 27 25 23 21
67 60 53 48 43 38 35 32 29 26 24
67 59 51 45 40 36 32 29 26 24 22
64 58 52 47 42 38 34 31 28 26 24
64 57 50 44 40 35 32 29 26 24 22
61 56 51 46 41 37 34 31 28 26 24
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
61 55 49 44 39 35 35 28 26 23 22
90 402 402 407 419 438 452 463 487 505 500 502 483 451 405 360 348 265 177 34 3 2 1 0
45 558 . . . . . 559 . . . . . 656 . . . . . 567 . . . . . 599 . . . . . 607 . . . . . 630 . . . . . 648 . . . . . 654 . . . . . 650 . . . . . 647 . . . . . 636 . . . . . 602 . . . . . 557 . . . . . 494 . . . . . 454 . . . . . 336 . . . . . 249 . . . . . 38 . . . . . . 4 . . . . . . . 2 . . . . . . . 1 . . . . . . . 0 . . . . . . .
90 558 558 565 582 608 628 644 676 702 695 698 672 626 562 500 484 368 246 47 4 2 1 0
test no.: lli 0204-14c spacing criteria: 1.34
Candela Tabulation 0 0 . . . . . 1055 . . . . . 1 . . . . . 1054 . . . . . 3 . . . . . 1053 . . . . . 5 . . . . . 1050 . . . . . 7 . . . . . 1050 . . . . . 9 . . . . . 1051 . . . . . 11 . . . . 1057 . . . . . 13 . . . . 1062 . . . . . 15 . . . . 1061 . . . . . 17 . . . . 1051 . . . . . 19.5 . . . 1019 . . . . . 22.5 . . . 964 . . . . . . 25.5 . . . 958 . . . . . . 29 . . . . 925 . . . . . . 33 . . . . 856 . . . . . . 37.5 . . . 816 . . . . . . 42.5 . . . 631 . . . . . . 47.5 . . . 438 . . . . . . 55 . . . . 67 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .
45 1055 . . . . 1059 . . . . 1091 . . . . 1147 . . . . 1190 . . . . 1239 . . . . 1260 . . . . 1280 . . . . 1288 . . . . 1281 . . . . 1251 . . . . 1194 . . . . 1130 . . . . 1058 . . . . 964 . . . . . 881 . . . . . 694 . . . . . 532 . . . . . 88 . . . . . . 10 . . . . . . 6 . . . . . . . 3 . . . . . . . 0 . . . . . . .
90 1055 1058 1099 1166 1218 1261 1288 1297 1279 1239 1209 1177 1128 1083 996 970 797 582 108 9 5 4 0
67
6”
hs8pl fluorescent series 8” horizontal fluorescent shallow downlighting
new A. Height = 5” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 10” f. Length = 12-1/2”
5”
( SHALLOW )
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HS8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
8”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
8701-Reflector
8714-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8702-Baffle Reflector
8715-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
8703-Reflector/Fresnel Glass Lens
8716-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
8704-Reflector/Prismatic Glass Lens
8717-Baffle/Prismatic Plastic Lens
w
frost
8705-Baffle/Fresnel Glass Lens
8718-Reflector/Tempered Clear Plastic
mb
8706-Baffle/Prismatic Glass Lens
8719-Baffle/Tempered Clear Plastic
fuse
8707-Wall Wash Reflector
8709-Deco Glass Ring
rif
8708-Crossblade Reflector
8710-Double Ring
8712-Baffle/Frosted Glass Lens
8711-Triple Ring
Other Options
8713-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8709, 8710 MB Black SCH** Self-Flange Chrome and 8711. W White ** Only available on 8701 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HS8PL-1X18-FDB-T418-120-EMG 750-8701-CL-WH 68
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” horizontal fluorescent shallow trims 8708-CL
8701-CL
8702-WH-CL
8707-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
8703-CL
8714-CL
8704-CL
8715-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 9-1/8”
8” 8712-WH
8705-P
8706-WH
8713-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8716-CL
8717-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
8718-WT
8719-WH
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
69
8” horizontal fluorescent shallow trims
8”
70
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” horizontal fluorescent shallow trims 8721-CL
8722-CL
8723-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
8724-CL geo deco ring glass
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8727-CL
8725-CL
8726-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
8” 8710-CL
8711-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
8709-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
71
hh8pl fluorescent series 8” horizontal fluorescent downlighting
A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HH8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
8”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
8501-Reflector
8514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8502-Baffle Reflector
8515-Reflector/Tempered Glass Lens
p
shz*
red
intg 750
8503-Reflector/Fresnel Glass Lens
8516-Reflector/Prismatic Plastic Lens
wt
green
intg 1300
8504-Reflector/Prismatic Glass Lens
8517-Baffle/Prismatic Plastic Lens
w
frost
emg-d-750
8505-Baffle/Fresnel Glass Lens
8518-Reflector/Tempered Clear Plastic
mb
intg-d-750
8506-Baffle/Prismatic Glass Lens
8519-Baffle/Tempered Clear Plastic
ice-1300
8507-Wall Wash Reflector
8509-Deco Glass Ring
Other Options
8508-Crossblade Reflector
8510-Double Ring
fuse
8512-Baffle/Frosted Glass Lens
8511-Triple Ring
rif
8513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HH8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH 72
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hhr8pl fluorescent series 8” horizontal fluorescent remodel downlighting
A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2” g. Flange = 2-1/4”
DESCRIPTION:
TRIMS:
Designed for remodel applications. Four remodel clips are easily retractable for fixture removal if necessary.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HHR8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
8”
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Glass
emg 750
8501-Reflector
8514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8502-Baffle Reflector
8515-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
8503-Reflector/Fresnel Glass Lens
8516-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
8504-Reflector/Prismatic Glass Lens
8517-Baffle/Prismatic Plastic Lens
w
frost
8505-Baffle/Fresnel Glass Lens
8518-Reflector/Tempered Clear Plastic
mb
Other Options
8506-Baffle/Prismatic Glass Lens
8519-Baffle/Tempered Clear Plastic
fuse
8507-Wall Wash Reflector
8509-Deco Glass Ring
rif
8508-Crossblade Reflector
8510-Double Ring
8512-Baffle/Frosted Glass Lens
8511-Triple Ring
8513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HHR8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
73
hhj8pl fluorescent series 8” horizontal fluorescent retrofit downlighting
A. Height = 6-1/4” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8”
universal n installatio
(frame not included)
DESCRIPTION:
TRIMS:
Designed to install into an existing downlights mounting frame and convert them into energy efficient fluorescent downlights. Fits all downlights with 8-1/8” aperture.
3. REFLECTOR - .050” aluminum reflector with low iridescent finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
4. GROVE BAFFLE - One-piece aluminum with concentric rings.
2. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
5. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HHJ8PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
8”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
8501-Reflector
8514-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
8502-Baffle Reflector
8515-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
8503-Reflector/Fresnel Glass Lens
8516-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
8504-Reflector/Prismatic Glass Lens
8517-Baffle/Prismatic Plastic Lens
w
frost
8505-Baffle/Fresnel Glass Lens
8518-Reflector/Tempered Clear Plastic
mb
Other Options
8506-Baffle/Prismatic Glass Lens
8519-Baffle/Tempered Clear Plastic
fuse
8507-Wall Wash Reflector
8509-Deco Glass Ring
rif
8508-Crossblade Reflector
8510-Double Ring
8512-Baffle/Frosted Glass Lens
8511-Triple Ring
8513-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 8509, 8510 MB Black SCH** Self-Flange Chrome and 8511. W White ** Only available on 8501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HHJ8PL-1X18-FDB-T418-120-EMG 750-8501-CL-WH 74
Glass
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” horizontal fluorescent trims 8508-CL
8501-CL
8502-WH-CL
8507-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
8503-CL
8514-CL
8504-CL
8515-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 9-1/8”
8” 8512-WH
8505-P
8506-WH
8513-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8516-CL
8517-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
8518-WT
8519-WH
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8501-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
75
8” horizontal fluorescent trims
8”
76
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
8” horizontal fluorescent trims 8521-CL
8522-CL
8523-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
8524-CL geo deco ring glass
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
8527-CL
8525-CL
8526-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
8” 8510-CL
8511-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 9-1/8”
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 9-1/8”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
8509-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 8501-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
77
photometric data hh8pl-1x26-e-8501cl / hhr8pl-1x26-e-8501cl / hhj8pl-1x26-e-8501cl lamp: sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 1800
Zonal Lumens Summary Zone Lumens 0-300 663.38 0-400 1031.46 0-600 1268.04 0-900 1284.21 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 1284.21
test no.: lli 0205-10m
total luminaire efficiency: 71.3%
%Lamp 36.9 57.3 70.4 71.3 0 0 0 0 71.3
Luminance Data (cd/sq.m)
%Fixt 51.7 80.3 98.7 100 0 0 0 0 100
spacing criteria: 1.18
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
7513 712 372 364 721
6135 767 372 364 721
7890 822 372 364 721
Zone Lumens 0-10 . . . . . . . . . . 63.16 10-20 . . . . . . . . . 238.75 20-30 . . . . . . . . . 361.46 30-40 . . . . . . . . . 368.08 40-50 . . . . . . . . . 207.31 50-60 . . . . . . . . . 29.26 60-70 . . . . . . . . . 9.28 70-80 . . . . . . . . . 3.89 80-90 . . . . . . . . . 3.01
Total Luminaire Efficiency = 71.3%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
48.5 21.6 12.1 7.8 5.4
7.7’ 11.6’ 15.5’ 19.3’ 23.2’
Initial Nadir Footcandles
Beam Spread
R oom C av i t y R a t io
Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 79 77 75 73 74 70 67 65 69 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance
79 74 68 63 58 54 50 46 43 40 37
76 71 66 61 56 52 48 45 42 39 36
73 68 64 59 55 51 47 44 41 38 36
71 65 59 54 49 44 41 37 34 31 29
79 72 65 60 54 50 45 42 38 36 33
79 71 63 57 51 47 42 39 35 33 30
76 70 64 58 53 49 45 41 38 35 33
76 69 62 56 51 51 42 38 35 32 30
73 68 62 57 52 48 44 41 38 35 32
73 67 61 55 50 46 42 38 35 32 30
Candela Tabulation 0 0 . . . . . 776 . . . . . . 1 . . . . . 793 . . . . . . 3 . . . . . 808 . . . . . . 5 . . . . . 804 . . . . . . 7 . . . . . 807 . . . . . . 9 . . . . . 806 . . . . . . 11 . . . . 812 . . . . . . 13 . . . . 814 . . . . . . 15 . . . . 791 . . . . . . 17 . . . . 730 . . . . . . 19.5 . . . 712 . . . . . . 22.5 . . . 766 . . . . . . 25.5 . . . 753 . . . . . . 29 . . . . 767 . . . . . . 33 . . . . 766 . . . . . . 37.5 . . . 436 . . . . . . 42.5 . . . 253 . . . . . . 47.5 . . . 85 . . . . . . . 55 . . . . 13 . . . . . . . 65 . . . . 5 . . . . . . . . 75 . . . . 3 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .
hh8pl-1x32-e-8501cl / hhr8pl-1x32-e-8501cl / hhj8pl-1x32-e-8501cl lamp: sylvania cf32dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 2400
Zone Lumens 0-300 884.97 0-400 1375.99 0 0-60 1691.71 0 0-90 1712.49 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 1712.49
8”
%Lamp 36.9 57.3 70.5 71.4 0 0 0 0 71.4
Luminance Data (cd/sq.m)
%Fixt 51.7 80.4 98.8 100 0 0 0 0 100
Ave. 00
Ave. 450
Ave. 900
45 550 650 750 850
10046 932 446 486 721
8179 986 521 486 721
10558 1096 521 486 721
0
spacing criteria: 1.18
Zonal Lumen Summary
Angle In Degrees
Zone Lumens 0-10 . . . . . . . . . . 84.26 10-20 . . . . . . . . . 318.49 20-30 . . . . . . . . . 484.22 30-40 . . . . . . . . . 491.02 40-50 . . . . . . . . . 276.68 50-60 . . . . . . . . . 39.04 60-70 . . . . . . . . . 12.18 70-80 . . . . . . . . . 5.11 80-90 . . . . . . . . . 3.48
Total Luminaire Efficiency = 71.4%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
64.8 28.8 16.2 10.4 7.2
7.7’ 11.6’ 15.5’ 19.3’ 23.2’
Initial Nadir Footcandles
Beam Spread
R oom C av i t y R a t io
Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 79 77 75 73 74 70 67 65 70 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance
79 74 68 63 58 54 50 46 43 40 37
76 71 66 61 56 52 48 45 42 39 36
73 68 64 59 55 51 47 44 41 38 36
71 65 59 54 49 44 41 37 34 31 29
79 72 65 60 54 50 45 42 38 36 33
79 71 63 57 51 47 42 39 35 33 30
76 70 64 58 53 49 45 41 38 35 33
76 69 62 56 51 51 42 38 35 32 30
73 68 62 57 52 48 44 41 38 35 32
73 67 61 55 50 46 42 38 35 32 30
Candela Tabulation 0 0 . . . . . 1036 . . . . . 1 . . . . . 1058 . . . . . 3 . . . . . 1078 . . . . . 5 . . . . . 1073 . . . . . 7 . . . . . 1076 . . . . . 9 . . . . . 1075 . . . . . 11 . . . . 1083 . . . . . 13 . . . . 1086 . . . . . 15 . . . . 1056 . . . . . 17 . . . . 974 . . . . . . 19.5 . . . 950 . . . . . . 22.5 . . . 1022 . . . . . 25.5 . . . 1005 . . . . . 29 . . . . 1023 . . . . . 33 . . . . 1021 . . . . . 37.5 . . . 581 . . . . . . 42.5 . . . 338 . . . . . . 47.5 . . . 114 . . . . . . 55 . . . . 17 . . . . . . . 65 . . . . 6 . . . . . . . . 75 . . . . 4 . . . . . . . . 85 . . . . 2 . . . . . . . . 90 . . . . 0 . . . . . . . .
hh8pl-1x42-e-8501cl / hhr8pl-1x42-e-8501cl / hhj8pl-1x42-e-8501cl lamp: sylvania cf42dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 3200
Zone Lumens 0-300 1179.45 0-400 1833.82 0 0-60 2254.53 0 0-90 2282.77 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2282.77
%Lamp 36.9 57.3 70.5 71.3 0 0 0 0 71.3
%Fixt 51.7 80.3 98.8 100 0 0 0 0 100
Luminance Data (cd/sq.m) Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
13403 1260 669 607 1082
10913 1315 744 607 1082
14069 1418 744 607 1082
Zone Lumens 0-10 . . . . . . . . . . 112.3 10-20 . . . . . . . . . 424.51 20-30 . . . . . . . . . 642.64 30-40 . . . . . . . . . 654.37 40-50 . . . . . . . . . 368.71 50-60 . . . . . . . . . 52 60-70 . . . . . . . . . 16.39 70-80 . . . . . . . . . 6.95 80-90 . . . . . . . . . 4.9
Total Luminaire Efficiency = 71.3%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
86.3 38.3 21.6 13.8 9.6
7.7’ 11.6’ 15.5’ 19.3’ 23.2’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
78
R oom Ca v it y R a t io
Beam Angle: 88 Degrees 4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 85 85 85 85 1 80 78 76 74 2 76 72 68 66 3 71 66 62 58 4 67 60 56 52 5 62 56 51 47 6 59 51 46 43 7 55 47 42 39 8 52 44 39 36 9 49 41 36 33 10 46 38 33 30 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
83 83 83 83 79 77 75 73 74 70 67 65 69 65 61 58 65 60 55 52 61 55 50 47 57 51 46 43 54 47 42 39 51 44 39 36 48 40 36 33 45 38 33 30 RW - Wall Reflectance
79 74 68 63 58 54 50 46 43 40 37
76 71 66 61 56 52 48 45 42 39 36
73 68 64 59 55 51 47 44 41 38 36
71 65 59 54 49 44 41 37 34 31 29
79 72 65 60 54 50 45 42 38 36 33
79 71 63 57 51 47 42 39 35 33 30
76 70 64 58 53 49 45 41 38 35 33
76 69 62 56 51 51 42 38 35 32 30
90 1036 1047 1055 1065 1087 1103 1133 1169 1185 1155 1085 1168 1237 1265 1107 770 389 86 20 7 4 2 0
spacing criteria: 1.18
Zonal Lumen Summary
Angle In Degrees
45 1036 . . . . 1054 . . . . 1082 . . . . 1065 . . . . 1098 . . . . 1119 . . . . 1112 . . . . 1067 . . . . 1056 . . . . 1046 . . . . 1066 . . . . 1065 . . . . 1049 . . . . 1006 . . . . 927 . . . . . 607 . . . . . 289 . . . . . 79 . . . . . . 18 . . . . . . 7 . . . . . . . 4 . . . . . . . 2 . . . . . . . 0 . . . . . . .
test no.: lli 0205-10z
total luminaire efficiency: 71.3%
Zonal Lumens Summary
90 776 785 791 799 815 827 849 876 888 866 813 875 928 948 829 577 577 64 15 5 3 2 0
test no.: lli 0205-10y
total luminaire efficiency: 71.4%
Zonal Lumens Summary
45 776 . . . . . 790 . . . . . 811 . . . . . 798 . . . . . 823 . . . . . 839 . . . . . 834 . . . . . 800 . . . . . 792 . . . . . 784 . . . . . 799 . . . . . 798 . . . . . 787 . . . . . 754 . . . . . 695 . . . . . 455 . . . . . 455 . . . . . 59 . . . . . . 14 . . . . . . 5 . . . . . . . 3 . . . . . . . 2 . . . . . . . 0 . . . . . . .
73 68 62 57 52 48 44 41 38 35 32
73 67 61 55 50 46 42 38 35 32 30
Candela Tabulation 0 0 . . . . . 1380 . . . . . 1 . . . . . 1411 . . . . . 3 . . . . . 1437 . . . . . 5 . . . . . 1430 . . . . . 7 . . . . . 1434 . . . . . 9 . . . . . 1433 . . . . . 11 . . . . 1443 . . . . . 13 . . . . 1447 . . . . . 15 . . . . 1407 . . . . . 17 . . . . 1298 . . . . . 19.5 . . . 1266 . . . . . 22.5 . . . 1362 . . . . . 25.5 . . . 1339 . . . . . 29 . . . . 1364 . . . . . 33 . . . . 1361 . . . . . 37.5 . . . 775 . . . . . . 42.5 . . . 451 . . . . . . 47.5 . . . 152 . . . . . . 55 . . . . 23 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
45 1380 . . . . 405 . . . . . 1443 . . . . 1419 . . . . 1463 . . . . 1491 . . . . 1482 . . . . 1423 . . . . 1407 . . . . 1394 . . . . 1421 . . . . 1419 . . . . 1399 . . . . 1340 . . . . 1235 . . . . 809 . . . . . 386 . . . . . 105 . . . . . 24 . . . . . . 10 . . . . . . 5 . . . . . . . 3 . . . . . . . 0 . . . . . . .
90 1380 1395 1406 1420 1449 1470 1510 1558 1580 1539 1446 1556 1649 1686 1475 1026 518 115 27 10 5 3 0
photometric data hh8pl-2x26-e-8501cl / hhr8pl-2x26-e-8501cl / hhj8pl-2x26-e-8501cl lamp: 2 sylvania cf26dt/e/in/841 Candle Power Distribution (Candelas)
lumens: 3200 (2 lamps)
Zonal Lumens Summary Zone Lumens 0-300 912.95 0-400 1489.47 0-600 2179.66 0-900 2229.4 90-1200 0 90-1300 0 90-1500 0 90-1800 0 0-1800 2229.4
%Lamp 25.4 41.4 60.5 61.9 0 0 0 0 61.9
test no.: lli 0205-10l
total luminaire efficiency: 61.9% Luminance Data (cd/sq.m)
%Fixt 41 66.8 97.8 100 0 0 0 0 100
spacing criteria: 1.38
Zonal Lumen Summary
Angle In Degrees
Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
15136 1699 669 607 1082
23138 1863 744 607 1082
29339 4603 818 607 1082
Zone Lumens 0-10 . . . . . . . . . . 80.1 10-20 . . . . . . . . . 332.63 20-30 . . . . . . . . . 500.22 30-40 . . . . . . . . . 576.51 40-50 . . . . . . . . . 542.65 50-60 . . . . . . . . . 147.54 60-70 . . . . . . . . . 37.05 70-80 . . . . . . . . . 7.69 80-90 . . . . . . . . . 5
Total Luminaire Efficiency = 61.9%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
62.5 27.8 15.6 10.0 6.9
8.3’ 12.4’ 16.6’ 20.7’ 24.9’
Initial Nadir Footcandles
Beam Spread
R oom C avi t y R a t io
Beam Angle: 92 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 74 74 74 74 1 69 67 65 64 2 65 61 58 55 3 60 55 51 48 4 56 50 46 43 5 52 46 41 38 6 49 42 37 34 7 45 38 34 30 8 42 35 31 27 9 40 32 28 25 10 37 30 26 23 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
72 72 72 72 68 66 64 63 63 60 57 55 59 54 51 48 55 49 45 42 51 45 41 38 48 41 37 34 44 38 33 30 42 35 30 27 39 32 28 25 37 30 25 23 RW - Wall Reflectance
69 63 58 53 48 44 40 37 34 31 29
66 61 56 51 47 43 39 36 33 31 29
63 59 54 50 45 42 38 35 33 30 28
62 56 50 44 40 35 32 29 26 23 21
69 62 55 50 45 40 36 33 30 27 25
69 61 53 47 42 37 33 30 27 25 22
66 60 54 48 44 39 36 32 30 27 25
66 59 52 46 41 37 33 30 27 25 22
63 58 52 47 43 39 35 32 29 27 25
63 57 51 46 41 36 33 30 27 24 22
hh8pl-2x32-e-8501cl / hhr8pl-2x32-e-8501cl / hhj8pl-2x32-e-8501cl lamp: 2 ge f32tbx/spx/841/a/4p/aol Candle Power Distribution (Candelas)
lumens: 4400 (2 lamps)
Zone Lumens 0-300 1031 0-400 1647.17 0 0-60 2459.18 0 0-90 2538.55 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 2538.55
%Lamp 23.4 37.4 55.9 57.7 0 0 0 0 57.7
Luminance Data (cd/sq.m)
%Fixt 40.6 64.9 96.9 100 0 0 0 0 100
Ave. 00
Ave. 450
Ave. 900
45 550 650 750 850
27672 4384 744 607 1083
34918 8220 893 1093 2885
32073 6138 1190 1457 3607
0
Zone Lumens 0-10 . . . . . . . . . . 96.6 10-20 . . . . . . . . . 380.76 20-30 . . . . . . . . . 553.64 30-40 . . . . . . . . . 616.17 40-50 . . . . . . . . . 616.41 50-60 . . . . . . . . . 195.6 60-70 . . . . . . . . . 58.75 70-80 . . . . . . . . . 10.87 80-90 . . . . . . . . . 9.75
Total Luminaire Efficiency = 57.7%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
73.9 32.8 18.5 11.8 8.2
9.2’ 13.8’ 18.4’ 23.0’ 27.6’
Initial Nadir Footcandles
Beam Spread
R oom C av i t y R a t io
Beam Angle: 98 Degrees 4’ 6’ 8’ 10’ 12’
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
80% 70% 50% 30% 10%
0 69 69 69 69 1 65 63 61 59 2 60 57 54 51 3 56 51 48 45 4 52 46 42 39 5 48 42 38 35 6 45 39 34 31 7 42 35 31 28 8 39 32 28 25 9 37 30 26 23 10 35 28 24 21 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
67 67 67 67 63 61 60 58 59 56 53 51 55 50 47 44 51 46 42 39 47 42 38 35 44 38 34 31 41 35 31 28 38 32 28 25 36 30 26 23 34 27 23 21 RW - Wall Reflectance
64 59 54 49 44 41 37 34 31 29 27
61 57 52 47 43 39 36 33 31 28 26
59 55 50 46 42 38 35 33 30 28 26
58 52 46 41 36 33 29 26 24 22 20
64 58 51 46 41 37 33 30 28 25 23
64 56 49 43 38 34 31 28 25 23 21
61 56 50 45 40 36 33 30 27 25 23
61 55 48 43 38 34 30 27 25 23 21
59 54 49 44 40 36 32 30 27 25 23
59 53 47 42 38 34 30 27 25 22 21
hh8pl-2x42-e-8501cl / hhr8pl-2x42-e-8501cl / hhj8pl-2x42-e-8501cl lamp: 2 sylvania cf42dt/e/in/835 Candle Power Distribution (Candelas)
lumens: 6400 (2 lamps)
Zone Lumens 0-300 1257.58 0-400 1998.63 0 0-60 3060.22 0 0-90 3173.88 0 90-120 0 0 90-130 0 90-1500 0 0 90-180 0 0 0-180 3173.88
%Lamp 19.6 31.2 47.8 49.6 0 0 0 0 49.6
%Fixt 39.6 63 96.4 100 0 0 0 0 100
Luminance Data (cd/sq.m) Ave. 00
Ave. 450
Ave. 900
450 550 650 750 850
39541 8713 1041 850 1443
43586 11344 1190 1822 5049
43030 8659 1636 2186 5410
Zone Lumens 0-10 . . . . . . . . . . 116.12 10-20 . . . . . . . . . 465.36 20-30 . . . . . . . . . 676.1 30-40 . . . . . . . . . 741.06 40-50 . . . . . . . . . 785.42 50-60 . . . . . . . . . 276.16 60-70 . . . . . . . . . 83.44 70-80 . . . . . . . . . 15.37 80-90 . . . . . . . . . 14.86
Total Luminaire Efficiency = 49.6%
Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 20% = PF RC RW
Distance to Plane
88.1 39.1 22.0 14.1 9.8
9.5’ 14.3’ 19.1’ 23.8’ 28.6’
Initial Nadir Footcandles
Beam Spread
BEAM DIA. MEASURED AT 10% OF NADIR F.C.
Room C av it y R a ti o
Beam Angle: 100 Degrees 4’ 6’ 8’ 10’ 12’
80% 70% 50% 30% 10%
0 59 59 59 59 1 55 54 52 51 2 52 48 46 44 3 48 44 41 38 4 45 40 36 33 5 41 36 32 29 6 38 33 29 26 7 36 30 26 24 8 34 28 24 21 9 31 25 22 19 10 29 23 20 18 RC - Ceiling Cavity Reflectance
70% 70% 50% 30% 10%
50% 50% 30% 10%
30% 50% 30% 10%
10% 50% 30% 10%
0% 0%
58 58 58 58 54 53 51 50 50 48 45 43 47 43 40 38 43 39 36 33 40 35 32 29 38 32 29 26 35 30 26 23 33 27 24 21 31 25 22 19 29 23 20 18 RW - Wall Reflectance
55 50 46 42 38 35 32 29 27 25 23
53 49 44 40 37 34 31 28 26 24 22
51 47 43 39 36 33 30 28 25 24 22
50 45 39 35 31 28 25 22 20 18 17
55 49 44 39 35 31 28 26 23 21 20
55 48 42 37 33 29 26 23 21 19 17
53 48 43 38 34 31 28 25 23 21 19
53 47 41 36 32 29 26 23 21 19 17
45 1182 . . . . 1184 . . . . 1218 . . . . 1257 . . . . 1318 . . . . 1362 . . . . 1393 . . . . 1406 . . . . 1405 . . . . 1404 . . . . 1405 . . . . 1412 . . . . 1403 . . . . 1403 . . . . 1375 . . . . 1239 . . . . 981 . . . . . 590 . . . . . 150 . . . . . 12 . . . . . . 9 . . . . . . . 8 . . . . . . . 0 . . . . . . .
90 1182 1183 1227 1276 1342 1408 1448 1476 1490 1465 1422 1399 1378 1333 1299 1205 933 510 112 16 12 10 0
spacing criteria: 1.40
Zonal Lumen Summary
Angle In Degrees
Candela Tabulation 0 0 . . . . . 1182 . . . . . 1 . . . . . 1187 . . . . . 3 . . . . . 1181 . . . . . 5 . . . . . 1163 . . . . . 7 . . . . . 1186 . . . . . 9 . . . . . 1213 . . . . . 11 . . . . 1243 . . . . . 13 . . . . 1272 . . . . . 15 . . . . 1290 . . . . . 17 . . . . 1291 . . . . . 19.5 . . . 1256 . . . . . 22.5 . . . 1215 . . . . . 25.5 . . . 1232 . . . . . 29 . . . . 1259 . . . . . 33 . . . . 1234 . . . . . 37.5 . . . 1109 . . . . . 42.5 . . . 814 . . . . . . 47.5 . . . 431 . . . . . . 55 . . . . 80 . . . . . . . 65 . . . . 10 . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .
test no.: lli 0205-10x
total luminaire efficiency: 49.6%
Zonal Lumens Summary
90 1000 997 1017 1061 1119 1186 1255 1300 1345 1352 1305 1295 1296 1233 1199 1141 869 451 84 11 5 3 0
spacing criteria: 1.38
Zonal Lumen Summary
Angle In Degrees
45 1000 . . . . 986 . . . . . 952 . . . . . 936 . . . . . 980 . . . . . 1006 . . . . 1033 . . . . 1050 . . . . 1061 . . . . 1045 . . . . 1034 . . . . 1051 . . . . 1058 . . . . 1079 . . . . 1117 . . . . 1007 . . . . 695 . . . . . 346 . . . . . 34 . . . . . . 10 . . . . . . 5 . . . . . . . 3 . . . . . . . 0 . . . . . . .
test no.: lli 0205-10w
total luminaire efficiency: 57.7%
Zonal Lumens Summary
Candela Tabulation 0 0 . . . . . 1000 . . . . . 1 . . . . . 994 . . . . . . 3 . . . . . 947 . . . . . . 5 . . . . . 895 . . . . . . 7 . . . . . 879 . . . . . . 9 . . . . . 889 . . . . . . 11 . . . . 902 . . . . . . 13 . . . . 920 . . . . . . 15 . . . . 955 . . . . . . 17 . . . . 971 . . . . . . 19.5 . . . 936 . . . . . . 22.5 . . . 888 . . . . . . 25.5 . . . 841 . . . . . . 29 . . . . 974 . . . . . . 33 . . . . 986 . . . . . . 37.5 . . . 866 . . . . . . 42.5 . . . 542 . . . . . . 47.5 . . . 139 . . . . . . 55 . . . . 31 . . . . . . . 65 . . . . 9 . . . . . . . . 75 . . . . 5 . . . . . . . . 85 . . . . 3 . . . . . . . . 90 . . . . 0 . . . . . . . .
51 46 42 37 34 30 28 25 23 21 19
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
51 45 40 36 32 28 26 23 21 19 17
Candela Tabulation 0 0 . . . . . 1409 . . . . . 1 . . . . . 1416 . . . . . 3 . . . . . 1430 . . . . . 5 . . . . . 1440 . . . . . 7 . . . . . 1459 . . . . . 9 . . . . . 1469 . . . . . 11 . . . . 1482 . . . . . 13 . . . . 1507 . . . . . 15 . . . . 1531 . . . . . 17 . . . . 1554 . . . . . 19.5 . . . 1570 . . . . . 22.5 . . . 1546 . . . . . 25.5 . . . 1535 . . . . . 29 . . . . 1517 . . . . . 33 . . . . 1478 . . . . . 37.5 . . . 1368 . . . . . 42.5 . . . 1096 . . . . . 47.5 . . . 683 . . . . . . 55 . . . . 159 . . . . . . 65 . . . . 14 . . . . . . . 75 . . . . 7 . . . . . . . . 85 . . . . 4 . . . . . . . . 90 . . . . 0 . . . . . . . .
45 1409 . . . . 1413 . . . . 1445 . . . . 1507 . . . . 1578 . . . . 1639 . . . . 1695 . . . . 1732 . . . . 1729 . . . . 1725 . . . . 1715 . . . . 1688 . . . . 1653 . . . . 1630 . . . . 1580 . . . . 1437 . . . . 1193 . . . . 768 . . . . . 207 . . . . . 16 . . . . . . 15 . . . . . . 14 . . . . . . 0 . . . . . . .
90 1409 1410 1457 1524 1601 1684 1747 1780 1793 1771 1726 1702 1668 1595 1540 1466 1207 729 158 22 18 15 0
79
8”
hh10pl fluorescent series 10” horizontal fluorescent downlighting
A. Height = 9-3/4” B. Trim Aperture = 9-3/4” c. Cut-out = 10-1/2” d. Trim Outside Dia. = 10-3/4” e. Width = 17-1/2” f. Length = 16-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HH10PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
10”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
2X32
-------
-------
FDB-T432-120-2
FDB-T432-277-2
2W-T432-120-2
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
2X42
-------
-------
FDB-T442-120-2
FDB-T442-277-2
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
1501-Reflector
wh
cl
emg 1300
1502-Baffle Reflector
p
shz*
intg 750
1503-Reflector/Fresnel Glass Lens
wt
intg 1300
1504-Reflector/Prismatic Glass Lens
w
emg-d-750
1505-Baffle/Fresnel Glass Lens
mb
intg-d-750
1506-Baffle/Prismatic Glass Lens
ice-1300
1512-Baffle/Frosted Glass Lens
fuse
1514-Reflector/Frosted Glass Lens
BAFFLE REFLECTOR RING WH White CL Clear WH Self-Flange White P Black WT Wheat Standard on all trims MB Black SCH** Self-Flange Chrome W White ** Only available on 1501 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only
rif
1515-Reflector/Tempered Glass Lens
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Other Options
1513-Baffle/Tempered Glass Lens
(EMG=Emergency battery pack w/ remote test switch) (INTG=Emergency battery pack w/ integral(reflector) test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (INTG-D=Emergency battery pack w/ integral(reflector) test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HH10PL-1X18-FDB-T418-120-EMG 750-1501-CL-WH 80
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
10” horizontal fluorescent trims 1501-CL
1502-WH-CL
REFLECTOR
baffle w/ REFLECTOR
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
RING finish: Wh, SCH, shz
reflector finish: CL
1503-CL
1504-CL
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ prismatic glass lens
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
1505-P
1506-WH
baffle w/ fresnel glass lens
baffle w/ prismatic glass lens
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
1512-WH
1513-WH
baffle w/ frosted glass lens
baffle w/ tempered clear glass
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
1514-CL
1515-WT
REFLECTOR w/ frosted glass lens
reflector w/ tempered clear glass
trim o. d.: 10-3/4”
trim o. d.: 10-3/4”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
10”
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 1501-WH-INTG
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
81
hw6pl fluorescent series 6” fluorescent lensed wall wash downlighting
A. Height = 6” B. Trim Aperture = 6-1/8” c. Cut-out = 6-3/4” d. Trim Outside Dia. = 7-3/8” e. Width = 16” f. Length = 12-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff.
3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation.
LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location.
4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HW6PL - ITEM SELECTOR: (Please check the boxes below for the option desired)
6”
LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options emg 750
Trim Type & Description
Reflector
6555-Lensed Wall Wash Reflector
Ring
cl
emg 1300
shz
emg-d-750
wt
ice-1300
w
WH
mb Other Options fuse rif
REFLECTOR CL Clear
RING WH Self-Flange White
WT MB W SHZ
Standard on all trims
Wheat Black White Satin Haze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HW6PL-1X18-FDB-T418-120-EMG 750-6555-CL-WH 82
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
hw8pl fluorescent series 8” fluorescent lensed wall wash downlighting
A. Height = 7-1/2” B. Trim Aperture = 8” c. Cut-out = 8-1/2” d. Trim Outside Dia. = 9-1/8” e. Width = 16” f. Length = 12-1/2”
DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HW8PL - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
8”
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
2X18
-------
-------
FDB-T418-120-2
FDB-T418-277-2
2W-T418-120-2
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
2X26
-------
-------
FDB-T426-120-2
FDB-T426-277-2
2W-T426-120-2
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options emg 750
Trim Type & Description
Reflector
8555-Lensed Wall Wash Reflector
cl
emg 1300
shz
emg-d-750
wt
ice-1300
w
Ring WH
mb Other Options fuse rif
REFLECTOR CL Clear
RING WH Self-Flange White
WT MB W SHZ
Standard on all trims
Wheat Black White Satin Haze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HW8PL-1X18-FDB-T418-120-EMG 750-8555-CL-WH www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
83
sloped ceiling adapter msca - maxilume sloped ceiling adapter
features: • The Sloped Ceiling Adapter provides an effective and attractive interface between sloped ceilings and Maxilume series of recessed downlighting. • Each adapter is scaled specifically to the aperture diameter of the luminaire. • The adapter may be specified for 10 – 30 degree slopes, in 5 degree increments. • The self-flanged, heavy gauge aluminum adapter is coated with a white, textured polyester powder finish for durability. • Mechanical design provides simplified installation with integral tabs. • Integral tabs support the adapter to the recessed downlight housing prior to installation of the trim.
sloped ceiling adapter ordering information and dimensional data degree of slope (pitch) sloped ceiling adapter
ceiling opening (dia.)
10º (2/12)
15º (3/12)
20º (4&5/12)
25º (6/12)
30º (7/12)
major axis height adder msca6
11” ( 27.9 cm )
3-7/8” ( 9.8 cm )
3-7/8” ( 9.8 cm )
3-7/8” ( 9.8 cm )
3-7/8” ( 9.8 cm )
3-7/8” ( 9.8 cm )
msca8
12-5/8” ( 32.1 cm )
4-1/4” ( 10.8 cm )
4-1/4” ( 10.8 cm )
4-1/4” ( 10.8 cm )
4-1/4” ( 10.8 cm )
4-1/4” ( 10.8 cm )
ordering information: (Please check the boxes below for the option desired) Series msca
Aperture
Degree of Slope
6”
10D
8”
15D 20D 25D 30D
84
Example: MSCA - 6 -10D
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
architectural downlighting
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
85
california title 24 compliant
elite lighting offers a wide range of products to comply with the new california title 24 residential lighting standards
These products are designed to respond to California’s energy crisis, reduce energy bills, increase energy delivery system reliability, energy efficiency measures that save energy at peak periods, and contribute to an improved economic condition for the state.
86
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” series compact fluorescent downlighting
engineered to perform. designed to save time. 6” air-shut downlighting Standard wago quick connects eliminate the need for wire nuts.
Pre-installed double headed nails and 90º pivot end ensure quick mounting and increased productivity.
The Elite bar hangers allow the fixture to be mounted within a full range of spacing. From a minimum of 9” to a maximum of 25”.
90º pivot ends
Hemmed bar hangers allow easy handling and special screw on frame allows secure locking.
Pre-installed double headed nails and 90º pivot end ensure quick mounting and increased productivity.
The Elite bar hangers allow the fixture to be mounted within a full range of spacing. From a minimum of 9” to a maximum of 25”.
Standard wago quick connects eliminate the need for wire nuts.
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
Hemmed bar hangers allow easy handling and special screw on frame allows secure locking.
87
hv4plic-at 4” vertical fluorescent ic downlighting
A. Min. Height = 7-3/4” B. Trim Aperture = 4-1/8” c. Cut-out = 4-1/2” d. Trim Outside Dia. = 5-1/2” e. Width = 8” f. Length = 12-1/2” DESCRIPTION: 1. LAMP HOLDER - Die-cast aluminum lamp holder effectively provides heat dissipation and ventilation. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from either outside the housing or inside the housing.
5. MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. TRIMS:
2. MOUNTING BRACKET - Constructed from 16-gauge steel and is supplied with C-channels that are adjustable up to 28”. Mounting brackets may be adjusted up to 2-3/4” vertically from inside the housing. 3. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. 4. JUNCTION BOX/BALLAST - UL and ETL listed for through-branch circuit wiring and has four 1/2” KO’s, one 3/4” KO and four Romex knockouts with pry-out slots and strain clamps. Ballast and Junction Box are accessible from below, no tools required. Ballast supplied is manufactured by Lutron.
4”
6. REFLECTOR - .050” aluminum reflector with low iridescent anodized finish. Reflector provides 45-degree lamp-to-reflector image cutoff. 7. GROVE BAFFLE - One-piece aluminum with concentric rings. 8. LENS - Choice of either tempered clear, tempered fresnel, tempered prismatic or tempered frosted lens fastened with two torsion springs for easy re-lamping. ETL listed for wet or damp location. listing ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
HV4PLic-at - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
------
-------
-------
-------
-------
-------
------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
emg 750
4101-Reflector
4114-Reflector/Frosted Glass Lens
wh
cl
blue
emg 1300
4102-Baffle Reflector
4115-Reflector/Tempered Glass Lens
p
shz*
red
emg-d-750
4103-Reflector/Fresnel Glass Lens
4116-Reflector/Prismatic Plastic Lens
wt
green
ice-1300
4104-Reflector/Prismatic Glass Lens
4117-Baffle/Prismatic Plastic Lens
w
frost
4105-Baffle/Fresnel Glass Lens
4118-Reflector/Tempered Clear Plastic
mb
4106-Baffle/Prismatic Glass Lens
4119-Baffle/Tempered Clear Plastic
fuse
4107-Wall Wash Reflector
4109-Deco Glass Ring
rif
4108-Crossblade Reflector
4110-Double Ring
4112-Baffle/Frosted Glass Lens
4111-Triple Ring
Other Options
4113-Baffle/Tempered Glass Lens
BAFFLE REFLECTOR RING GLASS WH White CL Clear WH Self-Flange White Only available P Black WT Wheat Standard on all trims on 4109, 4110 MB Black SCH** Self-Flange Chrome and 4111. W White ** Only available on 4101 CL SHZ Satin Haze SHZ* Satin Haze * Provided w/ satin haze ring only For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
Example: HV4PLIc-at-1X18-FDB-T418-120-EMG 750-4101-CL-WH 88
Glass
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
4” vertical fluorescent trims 4108-CL
4101-CL
4102-WH-CL
4107-SHZ
REFLECTOR
baffle w/ REFLECTOR
wall wash REFLECTOR
crossblade REFLECTOR
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wH, P
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, SHZ, w
RING finish: Wh, SCH, shz
reflector finish: CL
RING finish: Wh, SCH, shz
RING finish: Wh
4103-CL
4114-CL
4104-CL
4115-WT
REFLECTOR w/ prismatic glass lens
reflector w/ tempered clear glass
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
REFLECTOR w/ fresnel glass lens
REFLECTOR w/ frosted glass lens
trim o. d.: 5-1/2”
4” 4112-WH
4105-P
4106-WH
4113-WH
baffle w/ fresnel glass lens
baffle w/ frosted glass lens
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
4116-CL
4117-WH
REFLECTOR w/ prismatic plastic lens
baffle w/ prismatic PLASTIC lens
4118-WT
4119-WH
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
baffle w/ prismatic glass lens
baffle w/ tempered clear glass
reflector w/ tempered clear plastic
baffle w/ tempered clear plastic
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
baffle finish: wh, p
RING finish: Wh
RING finish: Wh
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
89
4” vertical fluorescent trims 4121-CL
4122-CL
4123-CL
stardust deco ring glass
euro deco ring glass
prism deco ring glass
new
new
new
4124-CL geo deco ring glass
new
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
RING finish: Wh
4127-CL
4125-CL
4126-CL
central etched float glass
diffusing screen wall wash glass
geo deco ring glass
new
new
new
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh
RING finish: Wh
RING finish: Wh
4” 4110-CL
4111-CL
deco glass reflector
double ring glass
triple ring glass
trim o. d.: 5-1/2”
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
trim o. d.: 5-1/2”
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
REFlector finish: CL, Wt, MB, SHZ, w
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
RING finish: Wh, shz
GLASS finish: Blue, red, green, frost
GLASS finish: Blue, red, green, frost
4109-CL
Blue
Blue
Blue
red
red
red
green
green
green
frost
frost
frost
(actual color may vary)
90
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
4” vertical fluorescent trims
4”
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
91
b4pl-e 4” miniature compact fluorescent non-ic downlighting
DESCRIPTION: Small aperture thermally protected, specification grade compact fluorescent recessed housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a
4”
double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
B4PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
B401-Stepped Baffle
B471-Square Baffle
w
cl
wh
emg 1300
B402-Reflector
B472-Square Reflector
p
shz
bk
emg-d-750
B406-Wall Wash/ Baffle
B444-Frosted Lens/Reflector
sn
wt
sn
ice-1300
B407-Wall Wash/Reflector
B462-Frosted Lens/Reflector
cp
w
cp
B420-Glass Trim
B454-Clear Lens/Reflector
bz
mb
ch
B438-Designer Point
B452-Albalite Lens
sn
pb
fuse
B437-Smooth Frost
B455-Fresnel Lens
rif
B439-Smooth Frost Dome
B451-Drop Opal Lens
Other Options
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B4PL-E-1X18-FDB-T418-120-EMG 750-B401-BZ-BZ 92
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b4plR-e 4” miniature compact fluorescent non-ic remodel downlighting
DESCRIPTION: Small aperture, thermally protected, specification grade compact fluorescent recessed housing. For remodel application non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs, and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing.
ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.
B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.
E. Junction box - ETL listed for feed through wiring with eight 1/2” KOs and four Romex knockouts with strain relief.
C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.
listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
D. Installation - Four Preinstalled spring clips which secure the housing firmly into
4”
B4PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
B401-Stepped Baffle
B471-Square Baffle
w
cl
wh
emg 1300
B402-Reflector
B472-Square Reflector
p
shz
bk
emg-d-750
B406-Wall Wash/ Baffle
B444-Frosted Lens/Reflector
sn
wt
sn
ice-1300
B407-Wall Wash/Reflector
B462-Frosted Lens/Reflector
cp
w
cp
B420-Glass Trim
B454-Clear Lens/Reflector
bz
mb
ch
B438-Designer Point
B452-Albalite Lens
sn
pb
fuse
B437-Smooth Frost
B455-Fresnel Lens
rif
B439-Smooth Frost Dome
B451-Drop Opal Lens
Other Options
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B4PLR-E-1X18-FDB-T418-120-EMG 750-B402-SN-SN www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
93
4” compact fluorescent trims b401cp-cp
b471cp-wh
b437wh
Stepped Baffle
square Stepped Baffle
smooth frost shower lite
new
new
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
baffle finish: p, w, sn, cp, bz
baffle finish: p, w, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
covered by u.s. patent
patent pending
b402cp-wh
b473cp-wh
b462cl-ch
reflector
square reflector
frosted lens with reflector
new
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
REFlector finish: mb, cl, rg, w, cp, sn
REFlector finish: mb, cl, rg, w, cp, sn
REFlector finish: mb, cl, rg, w, cp, sn
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
patent pending
4” b406p-wh
b407cl-wh
b454cp-wh
wall wash with Baffle
wall wash with reflector
clear lens with reflector
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
baffle finish: p, w, sn, cp, bz
REFlector finish: mb, cl, rg, w, cp, sn
REFlector finish: mb, cl, rg, w, cp, sn
RING/cover finish: bk, Wh
RING/cover finish: bk, Wh
RING finish: bk, Wh, ch, pb, sn, cp, bz
b420-red
b438wh
b455pb
glass trim
designer point shower lite
fresnel lens
new
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
trim o. d.: 4-7/8”
glass finish: green, yellow, pink, brown, white, orange, navy blue
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
94
covered by u.s. patent
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
4” compact fluorescent trims b439wh smooth frost dome shower lite
new
trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz covered by u.s. patent
b444cl-wh square frosted lens with reflector
new
trim o. d.: 4-7/8” REFlector finish: mb, cl, rg, w, cp, sn RING finish: bk, Wh, ch, pb, sn, cp, bz patent pending
4”
b452cp albalite lens
trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz
b451pb drop opal lens
trim o. d.: 4-7/8” RING finish: bk, Wh, ch, pb, sn, cp, bz
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
95
b5plic-e 5” compact fluorescent ic downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 9W, 13W, 18W or 26W compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a
5”
double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for direct contact with insulation, through-branch circuit wiring, and damp locations. Wet location only with lens trims.
B5PLIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b530-Baffle
b541-Reflector/Albalite Lens
w
cl
wh
emg 1300
b507-Reflector
b542-Reflector/Fresnel Lens
p
shz
bk
emg-d-750
b565-Cone Reflector/Baffle
b504L-Plastic Shower Lens
sn
wt
sn
ice-1300
b504-Shower Trim
b501L-Plastic Albalite Lens
cp
w
cp
b501-Albalite Lens
b505L-Plastic Fresnel Lens
bz
mb
ch
b505-Fresnel Lens
b520-Glass Trim
sn
pb
Other Options fuse
b525-Baffle/Frosted Dome
rif
b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B5PLIC-E-1X18-FDB-T418-120-EMG 750-B530-W-WH 96
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b5plric-e 5” compact fluorescent ic remodel downlighting
DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Accommodates (1) 9W, 13W, 18W or 26W compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed all aluminum construction for maximum heat dissipation and rust protection.
D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.
B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.
E. Junction box - ETL listed for feed through wiring provided with eight 1/2” KOs and four Romex knockouts with strain relief.
C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.
listing ETL and C-ETL listed for direct contact with insulation, through-branch circuit wiring, and damp locations. Wet location only with lens trims.
5”
B5PLric-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b530-Baffle
b541-Reflector/Albalite Lens
w
cl
wh
emg 1300
b507-Reflector
b542-Reflector/Fresnel Lens
p
shz
bk
emg-d-750
b565-Cone Reflector/Baffle
b504L-Plastic Shower Lens
sn
wt
sn
ice-1300
b504-Shower Trim
b501L-Plastic Albalite Lens
cp
w
cp
b501-Albalite Lens
b505L-Plastic Fresnel Lens
bz
mb
ch
b505-Fresnel Lens
b520-Glass Trim
sn
pb
Other Options fuse
b525-Baffle/Frosted Dome
rif
b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PLRIC-E-1X18-FDB-T418-120-EMG 750-B507-CL-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
97
b5pl-e 5” compact fluorescent non-ic downlighting
DESCRIPTION: Small aperture thermally protected, specification grade compact fluorescent recessed housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a
5”
double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
B5PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b530-Baffle
b541-Reflector/Albalite Lens
w
cl
wh
emg 1300
b507-Reflector
b542-Reflector/Fresnel Lens
p
shz
bk
emg-d-750
b565-Cone Reflector/Baffle
b504L-Plastic Shower Lens
sn
wt
sn
ice-1300
b504-Shower Trim
b501L-Plastic Albalite Lens
cp
w
cp
b501-Albalite Lens
b505L-Plastic Fresnel Lens
bz
mb
ch
b505-Fresnel Lens
b520-Glass Trim
sn
pb
Other Options fuse
b525-Baffle/Frosted Dome
rif
b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B5PL-E-1X18-FDB-T418-120-EMG 750-B530-W-WH 98
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b5plr-e 5” compact fluorescent non-ic remodel downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge deep drawn single piece housing. Adjusts vertically in plaster frame to accommodated 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span and can be shortened for 12” joists. They contain a
double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
5”
B5PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b530-Baffle
b541-Reflector/Albalite Lens
w
cl
wh
emg 1300
b507-Reflector
b542-Reflector/Fresnel Lens
p
shz
bk
emg-d-750
b565-Cone Reflector/Baffle
b504L-Plastic Shower Lens
sn
wt
sn
ice-1300
b504-Shower Trim
b501L-Plastic Albalite Lens
cp
w
cp
b501-Albalite Lens
b505L-Plastic Fresnel Lens
bz
mb
ch
b505-Fresnel Lens
b520-Glass Trim
sn
pb
Other Options fuse
b525-Baffle/Frosted Dome
rif
b535-Baffle/Albalite Lens b535-Baffle/Fresnel Lens
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B5PLR-E-1X18-FDB-T418-120-EMG 750-B507-CL-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
99
5” compact fluorescent trims
5”
100
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
5” compact fluorescent trims b530cp-cp
b507cp-wh
b535p-wh
b536w-wh
Baffle
reflector
Baffle with albalite lens
Baffle with fresnel lens
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz
available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch, sn-sn, bz-bz
available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz
available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz
b565w-cl
b565p-rg
b541rg-wh
b542cl-wh
cone reflector with Baffle
cone reflector with Baffle
reflector with albalite lens
reflector with fresnel lens
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
finish options: w-cl, p-cl
finish options: w-rg, p-rg
available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch,
available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch,
5” b504wh
b501cp
b504l
b501l
shower trim
albalite lens
plastic shower trim
plastic albalite lens
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
trim finish: white plastic
trim finish: white plastic
b505sn
b525wh
b505l
b520-green
fresnel lens
Baffle with frosted dome
plastic fresnel lens
glass trim
new
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
trim o. d.: 6-1/4”
RING finish: bk, Wh, ch, pb, sn, cp, bz
available color combinations: cp-cp, sn-sn, w-wh, p-wh, p-bk, bz-bz
trim finish: white plastic
glass finish: blue, yellow, pink, brown, white, red, orange, navy blue
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
101
b6plic-e 6” compact fluorescent ic downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceilings. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis
6”
of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - UL and ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.
B6PLic-e - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b725
b620
b755
b758
b789
w
cl
wh
emg 1300
b731
b723
b756
b759
b705l
p
shz
bk
emg-d-750
b722
b703
b741
b760
b706l
sn
wt
sn
ice-1300
af640
b704
b742
b781
b707l
cp
w
cp
b721
b751
b743
b787
bz
mb
ch
af632
b752
b707
b782
sn
pb
fuse
b701
b753
b737
b788
rif
b702
b705
b735
b785
b729
b706
b736
b796
b724
b754
b757
b780
Other Options
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PLIC-E-1X18-FDB-T418-120-EMG 750-B725-W-WH 102
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b6plric-e 6” compact fluorescent ic remodel downlighting
DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Accommodates (1) 4-pin compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed all aluminum construction for maximum heat dissipation and rust protection.
D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate ceiling thickness from 1/2” to 1-3/8”.
B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.
E. Junction box - ETL listed for feed through wiring and provided with eight 1/2” KOs and four Romex knockouts with strain relief.
C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.
listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.
6”
B6PLRIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b725
b620
b755
b758
b789
w
cl
wh
emg 1300
b731
b723
b756
b759
b705l
p
shz
bk
emg-d-750
b722
b703
b741
b760
b706l
sn
wt
sn
ice-1300
af640
b704
b742
b781
b707l
cp
w
cp
b721
b751
b743
b787
bz
mb
ch
af632
b752
b707
b782
sn
pb
fuse
b701
b753
b737
b788
rif
b702
b705
b735
b785
b729
b706
b736
b796
b724
b754
b757
b780
Other Options
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PLRIC-E-1X18-FDB-T418-120-EMG 750-B725-W-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
103
b6pl-e 6” compact fluorescent non-ic downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent housing. For new construction non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge cold rolled steel construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. D. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis
6”
of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary. E. Junction box - Listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
B6PL-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b725
b620
b755
b758
b789
w
cl
wh
emg 1300
b731
b723
b756
b759
b705l
p
shz
bk
emg-d-750
b722
b703
b741
b760
b706l
sn
wt
sn
ice-1300
af640
b704
b742
b781
b707l
cp
w
cp
b721
b751
b743
b787
bz
mb
ch
af632
b752
b707
b782
sn
pb
fuse
b701
b753
b737
b788
rif
b702
b705
b735
b785
b729
b706
b736
b796
b724
b754
b757
b780
Other Options
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PL-E-1X18-FDB-T418-120-EMG 750-B725-w-WH 104
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b6plr-e 6” compact fluorescent non-ic remodel downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent housing. For new construction, non-insulated ceilings or where insulation can be kept 3” from housing. Accommodates (1) compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - High temperature painted 22 gauge cold rolled steel construction for maximum heat dissipation and rust protection.
D. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling and accommodate different ceiling thicknesses from 1/2” to 1-3/8”.
B. Socket - One vertically mounted plug-in socket for CFL lamp. Preinstalled on an adjustable mounting bracket to allow for proper and consistent lamp positioning.
E. Junction box - ETL listed for feed through wiring and provided with eight 1/2” KOs and four Romex knockouts with strain relief.
C. Ballast - Thermally protected, current controlled rapid start ballast, will produce full light output, increase lamp life with no noise and flicke. Ballast supplied is manufactured by Lutron.
listing ETL and C-ETL listed for through-branch circuit wiring and damp locations. Wet location only with lens trims.
6”
B6PLR-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
1X42
-------
-------
FDB-T442-120-1
FDB-T442-277-1
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b725
b620
b755
b758
b789
w
cl
wh
emg 1300
b731
b723
b756
b759
b705l
p
shz
bk
emg-d-750
b722
b703
b741
b760
b706l
sn
wt
sn
ice-1300
af640
b704
b742
b781
b707l
cp
w
cp
b721
b751
b743
b787
bz
mb
ch
af632
b752
b707
b782
sn
pb
fuse
b701
b753
b737
b788
rif
b702
b705
b735
b785
b729
b706
b736
b796
b724
b754
b757
b780
Other Options
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PLR-E-1X18-FDB-T418-120-EMG 750-B725-W-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
105
b6plic-26 or 32-e 6” double-wall compact fluorescent ic downlighting
DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Accommodates (1) 26W or 32W 4pin compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Outer Housing - Die formed aluminum construction for maximum heat dissipating air chamber on top of the housing. Junction box could be accessed from inside and outside housing.
6”
B. Inner Housing - Die-formed, all aluminum construction for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceiling.
E. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary.
C. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing.
F. Junction box - ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps.
D. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron.
listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.
B6PLIC-26 or 32-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
-------
-------
-------
-------
-------
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
1X32
HL3-T432-120-1
HL3-T432-277-1
FDB-T432-120-1
FDB-T432-277-1
2W-T432-120-1
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b725
b620
b755
b758
b789
w
cl
wh
emg 1300
b731
b723
b756
b759
b705l
p
shz
bk
emg-d-750
b722
b703
b741
b760
b706l
sn
wt
sn
ice-1300
af640
b704
b742
b781
b707l
cp
w
cp
b721
b751
b743
b787
bz
mb
ch
af632
b752
b707
b782
sn
pb
fuse
b701
b753
b737
b788
rif
b702
b705
b735
b785
b729
b706
b736
b796
b724
b754
b757
b780
Other Options
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
bz BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B6PLIC-26-E-FDB-T426-120-EMG 750-B725-W-WH 106
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” compact fluorescent trims b725w-wh
b731w-wh
Baffle with frosted dome
full cone Baffle
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
baffle finish: p, w, sn, cp, bz
available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
b722w-cl
b702p-rg
cone reflector with Baffle
cone reflector with Baffle
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
available color combinations: w-cl-wh, p-cl-wh, w-w-wh
baffle finish: p, w reflector finish: cl, rg
6”
RING finish: bk, Wh, ch, pb, sn, cp, bz
b721cl-wh
b701cp-wh
cone reflector
cone reflector
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mb-bk, rg-pb, cl-ch, sn-sn
reflector finish: mb, cl, rg, w, cp, sn
af640w-wh
af632rg-wh
deep self-flange air-shut baffle
air-shut reflector
RING finish: bk, Wh, ch, pb, sn, cp, bz
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz, p-bk
available color combinations: cp-cp, w-wh, rg-wh, mb-wh, cl-wh, mbbk, rg-pb, cl-ch, sn-sn
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
107
6” compact fluorescent trims b620-orange
b729w-wh
glass trim
Baffle wall wash
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
glass finish: green, yellow, pink, brown, white, red, blue, navy blue
available color combinations: cp-cp, sn-sn, w-wh, p-wh, bz-bz
b724w-cl
b723mb-wh
reflector Baffle wall wash
wall wash reflector
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
available color combinations: w-cl-wh, p-cl-wh, w-w-wh
available color combinations: cl-wh, cl-ch, rg-wh, rg-pb, w-wh, mb-wh, cp-cp, sn-sn
wall wash cover: bk, Wh
6”
wall wash cover: bk, Wh
wall wash cover: bk, Wh
b704p-rg
b703rg-wh
b705cp
b706pb
reflector Baffle wall wash
wall wash reflector
metal albalite lens
metal fresnel lens
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
trim o. d.: 8”
trim o. d.: 8”
baffle finish: p, w
available color combinations: cl-wh, cl-ch, rg-wh, rg-pb, w-wh, mb-wh, cp-cp, sn-sn
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
reflector finish: cl, rg wall wash cover: bk, Wh
wall wash cover: bk, Wh
b751wh
b752wh
b753wh
b754wh
smooth frost dome shower lens
designer point shower lens
designer cone shower lens
smooth frost shower lens
new
new
new
new
trim o. d.: 8”
trim o. d.: 8”
trim o. d.: 8”
trim o. d.: 8”
lens: frosted
lens: frosted/clear
lens: frosted
lens: frosted
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
108
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” compact fluorescent trims
b755w-wh
b756cl-wh
b741rg-wh
b742rg-wh
Baffle with prismatic lens
reflector with prismatic lens
reflector with albalite lens
reflector with fresnel lens
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
baffle finish: p, w, sn, cp, bz
reflector finish: mb, cl, rg, w, cp, sn
reflector finish: mb, cl, rg, w, cp, sn
reflector finish: mb, cl, rg, w, cp, sn
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
MAX. 26W
MAX. 26W
MAX. 26W
MAX. 26W
b743rg-wh
b707cp
b737w-wh
b735p-wh
reflector with drop opal lens
metal drop opal lens
Baffle with drop opal lens
Baffle with albalite lens
trim o. d.: 7-1/4”
trim o. d.: 8”
trim o. d.: 7-1/4”
trim o. d.: 7-1/4”
reflector finish: mb, cl, rg, w, cp, sn
RING finish: bk, Wh, ch, pb, sn, cp, bz
baffle finish: p, w, sn, cp, bz
baffle finish: p, w, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
6”
MAX. 26W
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
109
6” compact fluorescent trims b736w-wh Baffle with fresnel lens
trim o. d.: 7-1/4” baffle finish: p, w, sn, cp, bz RING finish: bk, Wh, ch, pb, sn, cp, bz
MAX. 26W b705l plastic albalite lens
trim o. d.: 8” RING finish: white plastic
6” b706l plastic fresnel lens
trim o. d.: 8” RING finish: white plastic
b707l plastic drop opal lens
trim o. d.: 8” RING finish: white plastic
110
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” compact fluorescent trims b757w-wh
b781CP-wh
b787cp-wh
Baffle with frosted dome shower lens
square Baffle trim
square reflector trim
new
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/2”
trim o. d.: 7-1/2”
baffle finish: p, w, sn, cp, bz
baffle finish: p, w, sn, cp, bz
reflector finish: mb, cl, rg, w, cp, sn
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
patent pending
patent pending
MAX. 26W covered by u.s. patent
b758cl-wh
b782cl-wh
b788wh
reflector with frosted dome shower lens
square reflector/baffle trim
square albalite lens
new
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/2”
trim o. d.: 7-1/2”
reflector finish: mb, cl, rg, w, cp, sn
baffle finish: p, w, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
MAX. 26W
patent pending
patent pending
6”
covered by u.s. patent
b759cl-wh
b785wh
b796wh
reflector with frosted lens
square fresnel lens
square smooth frost dome lens
new
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/2”
trim o. d.: 7-1/2”
reflector finish: mb, cl, rg, w, cp, sn
lens: frosted
lens: frosted
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
patent pending
patent pending
MAX. 26W covered by u.s. patent
b760w-wh
b780wh
b789wh
Baffle with frosted lens
square designer point lens
square designer cone lens
new
new
new
trim o. d.: 7-1/4”
trim o. d.: 7-1/2”
trim o. d.: 7-1/2”
baffle finish: p, w, sn, cp, bz
lens: frosted/clear
lens: frosted
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
patent pending
patent pending
MAX. 26W covered by u.s. patent
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
111
b36plic-e 6” compact fluorescent slope ceiling ic downlighting
2/12 to 6/12 Pitch (9º to 27º)
DESCRIPTION: Thermally protected, specification grade compact fluorescent IC housing. For new construction where housing will be in direct contact with insulation. Designed for sloped ceiling applications where ceiling pitch ranges from 2/12 to 6/12 (9º to 27º). Accommodates (1) 4-pin Compact fluorescent lamp. Furnished with preinstalled adjustable bar hangers. Junction box is provided with four 1/2” KOs, one 3/4” KO and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die formed aluminum construction for for maximum heat dissipation and rust protection. Adjusts vertically in plaster frame to accommodate 1/2” to 1-3/8” ceilings. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. c. Bar hangers - Preinstalled bar hangers allow housing to be positioned and locked at any point within a 24” joist span. They can be positioned on either the long or short axis of the housing and can be shortened for 12” joists. They contain a double-headed real nail for secure attachment into the joist. Bar hanger nails are installed on a 20º downward angle for better contact, and the 90º pivoting mounting plate makes installation fast and accurate. Bar hangers can fit onto T-Bar spline with additional slots and holes for special mounting methods if necessary.
6”
d. Junction box - UL and ETL listed for through-branch circuit wiring and has four 1/2” KOs, one 3/4” KO and four Romex knockouts with true pry-out slots and strain clamps. e. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. Listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.
B36PLIC - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b391-Stepped Baffle
w
cl
wh
emg 1300
b397-Reflector
p
shz
bk
emg-d-750
b601-Metal Albalite Shower
sn
wt
sn
ice-1300
b605-Metal Fresnel Shower
cp
w
cp
b601L-Plastic Albalite Shower
bz
mb
ch
sn
pb
Other Options
b605L-Plastic Fresnel Shower
bz
fuse rif
BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B36PLIC-E-1X18-FDB-T418-120-EMG 750-B391-P-WH 112
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
b36plric-e 6” compact fluorescent slope ceiling ic remodel downlighting
2/12 to 6/12 Pitch (9º to 27º)
DESCRIPTION: Thermally protected, IC rated specification grade remodel compact fluorescent recessed housing. For remodeling installations where housing will be in direct contact with insulation. Designed for sloped ceiling applications where the ceiling pitch ranges from 2/12 to 6/12. Accommodates (1) compact fluorescent lamp. For fast and easy installation in existing plaster or mechanical ceilings from 1/2” to 1-3/8” thick. Four remodel clips are easily retractable for fixture removal if necessary. Junction box is provided with eight 1/2” KOs and four Romex knockouts with strain relief. SPECIFICATION: A. Housing - Die-formed, all aluminum construction for maximum heat dissipation and rust protection. B. Socket - One vertically mounted plug-in socket. Unitized optics guarantees proper trim to housing installation. Tool-less installation adjustability from inside the housing. C. Installation - Four Preinstalled spring clips which secure the housing firmly into ceiling to accommodate different ceiling thicknesses from 1/2” to 1-3/8”.
e. Ballast - Thermally protected, current controlled ballast, will produce full light output, increase lamp life with no noise and flicker. Ballast supplied is manufactured by Lutron. Listing ETL and C-ETL listed for through-branch circuit wiring, direct contact with insulation and damp locations. Wet location only with lens trims.
d. Junction box - Provided with eight 1/2” KOs and four Romex knockouts with strain reliefs.
6”
B36PLRIC-E - ITEM SELECTOR: (Please check the boxes below for the option desired) LUTRON Ballast Selector: Lamp Watts:
HI-Lume - 120V (1% Dimming)
HI-Lume - 277V (1% Dimming)
Compact SE - 120V (5% Dimming)
Compact SE - 277V (5% Dimming)
Tu-Wire - 120V only (5% Dimming)
1X18
-------
-------
FDB-T418-120-1
FDB-T418-277-1
-------
1X26
HL3-T426-120-1
HL3-T426-277-1
FDB-T426-120-1
FDB-T426-277-1
2W-T426-120-1
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
(HL3=Available only in 1X26W & 1X32W, 120V or 277V) (FDB=Available in all lamp wattages / 120V or 277V) (Tu-Wire=Available in 120V, 2X18W, 1X26W, 2X26W, 1X32W, 2X32W only)
Emergency Options
Trim Type & Description
Baffle
Reflector
Ring/Trim
emg 750
b391-Stepped Baffle
w
cl
wh
emg 1300
b397-Reflector
p
shz
bk
emg-d-750
b601-Metal Albalite Shower
sn
wt
sn
ice-1300
b605-Metal Fresnel Shower
cp
w
cp
b601L-Plastic Albalite Shower
bz
mb
ch
sn
pb
Other Options
b605L-Plastic Fresnel Shower
bz
fuse rif
BAFFLE: W White P Black SN Satin Nickel CP Copper BZ Bronze
(EMG=Emergency battery pack w/ remote test switch) (EMG-D=Emergency battery pack w/ remote test switch for damp location) (ICE=Emergency battery pack w/ remote test switch operating between -18ºC and 55ºC) (FUSE=Single slow-blow fuse) (RIF=Radio interference filter)
reflector: cl Chrome rg Gold W White MB Black cP Copper SN Satin Nickel
ring/Trim: wh White bk Black SN Satin Nickel cP Copper ch Chrome pb Polish Brass bz Bronze
For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.
Example: B36PLRIC-E-1X18-FDB-T418-120-EMG 750-B397-RG-WH www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
113
6” compact slope fluorescent trims b391p-wh
b397rg-wh
stepped Baffle
reflector
trim o. d.: 7-1/2”
trim o. d.: 7-1/2”
baffle finish: p, w
reflector finish: mb, cl, rg, w
RING finish: wh
RING finish: wh
b601cp
b605pb
metal albalite lens
metal fresnel lens
trim o. d.: 8”
trim o. d.: 8”
RING finish: bk, Wh, ch, pb, sn, cp, bz
RING finish: bk, Wh, ch, pb, sn, cp, bz
b601l
b605l
plastic albalite lens
plastic fresnel lens
trim o. d.: 8”
trim o. d.: 8”
RING finish: white plastic
RING finish: white plastic
6”
114
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
6” compact slope fluorescent trims
www.iuseelite.com • tel: 1-877-375-5555 • fax: 1-877-375-333
115
emergency battery pack description, part number and lumen output EMG 750 Emergency battery pack with remote test switch. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B94C-2-2 or IOTA I42EM-J. EMG –D-750 Emergency battery pack with remote test switch. To be used in damp location areas. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine BDL94C-2-2 or IOTA I42EM-R-DL. INTG 750 Emergency battery pack with integral test switch. Operates maximum single lamp 42W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B94C-2-6 or IOTA I42EM-R-J. INTG-D 750 Emergency battery pack with integral test switch. To be used in damp location areas. Operates 1 lamp in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine BDL94C-2-6 or IOTA I42EM-R-J-DL.
BODINE B94C/ BDL94C lamp type (4-pin) part number
IOTA I-42/ IOTA I-42 -DL lumens 1 lamp
lumens
lamp type (4-pin) part number
2 lamps
1 lamp
2 lamps
GE: F13DBX, SYLVANIA: CF13DD/E
350
425
GE: F13DBX, SYLVANIA: CF13DD/E
350
400
GE: F13TBX, SYLVANIA: CF13DT/E
350
425
GE: F13TBX, SYLVANIA: CF13DT/E
350
400
GE: F18DBX, SYLVANIA: CF18DD/E
475
575
GE: F18DBX, SYLVANIA: CF18DD/E
350
550
GE: F18TBX, SYLVANIA: CF18DT/E/IN
300
525
GE: F18TBX, SYLVANIA: CF18DT/E/IN
350
500
GE: F26DBX, SYLVANIA: CF26DD/E
600
700
GE: F26DBX, SYLVANIA: CF26DD/E
425 N/A
GE: F26TBX, SYLVANIA: CF26DT/E/IN
450
725
GE: F26TBX, SYLVANIA: CF26DT/E/I
425 N/A
GE: F32TBX, SYLVANIA: CF32DT/E/IN
575
750
GE: F32TBX, SYLVANIA: CF32DT/E/IN
600 N/A
GE: F42TBX, SYLVANIA: CF42DT/E/IN
750 N/A
GE: F42TBX, SYLVANIA: CF42DT/E/IN
750 N/A
EMG 1300 Super Emergency battery pack with remote test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B84CG-2-2 or IOTA I420-EM-A. INTG 1300 Super Emergency battery pack with integral test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B84CG-2-6 or IOTA I420-EMA-R.
Bodine B84CG-2-6 lamp type (4-pin) part number
IOTA I420-EMA-R lumens 1 lamp
GE: F13DBX, SYLVANIA: CF13DD/E
700 N/A
GE: F13TBX, SYLVANIA: CF13DT/E
700 N/A
GE: F18DBX, SYLVANIA: CF18DD/E
900 N/A
GE: F18TBX, SYLVANIA: CF18DT/E/IN
900 N/A
GE: F26DBX, SYLVANIA: CF26DD/E
700 N/A
GE: F26TBX, SYLVANIA: CF26DT/E/IN
700 N/A
GE: F32TBX, SYLVANIA: CF32DT/E/IN
1250 N/A
GE: F42TBX, SYLVANIA: CF42DT/E/IN
1250 N/A
116
lumens
lamp type (4-pin) part number
2 lamps
1 lamp
GE: F13DBX, SYLVANIA: CF13DD/E GE: F13TBX, SYLVANIA: CF13DT/E GE: F18DBX, SYLVANIA: CF18DD/E GE: F18TBX, SYLVANIA: CF18DT/E/IN GE: F26DBX, SYLVANIA: CF26DD/E GE: F26TBX, SYLVANIA: CF26DT/E/IN GE: F32TBX, SYLVANIA: CF32DT/E/IN GE: F42TBX, SYLVANIA: CF42DT/E/IN GE: F57TBX, SYLVANIA: CF57DT/E/IN GE: F70TBX, SYLVANIA: CF70DT/E/IN
2 lamps
600 675 600 675 600 950 600 950 725 1200 725 1200 1050 1250 1300 N/A 1160 N/A 1200 N/A
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-3333
emergency battery pack description, part number and lumen output ICE-1300 Extended Temperature Super Emergency battery pack(-20ºC to +50ºC) with remote test switch, provides a higher initial lumen output than a standard Emergency battery pack. Operates maximum single lamp 70W TRT or double lamp 32W TRT in emergency mode with battery back-up, in case of power failure. Supplied part number is either Bodine B4CF-2 or IOTA ICE-420-EM-A.
Bodine B4CF-2
ICE-420-EM-A
lamp type (4-pin) part number
lumens 1 lamp
lamp type (4-pin) part number
2 lamps
GE: F13DBX, SYLVANIA: CF13DD/E
700 N/A
GE: F13TBX, SYLVANIA: CF13DT/E
700 N/A
GE: F18DBX, SYLVANIA: CF18DD/E
900 N/A
GE: F18TBX, SYLVANIA: CF18DT/E/IN
900 N/A
GE: F26DBX, SYLVANIA: CF26DD/
700 N/A
GE: F26TBX, SYLVANIA: CF26DT/E/IN
700 N/A
GE: F32TBX, SYLVANIA: CF32DT/E/IN
1250 N/A
GE: F42TBX, SYLVANIA: CF42DT/E/IN
1250 N/A
lumens 1 lamp
GE: F13DBX, SYLVANIA: CF13DD/E GE: F13TBX, SYLVANIA: CF13DT/E GE: F18DBX, SYLVANIA: CF18DD/E GE: F18TBX, SYLVANIA: CF18DT/E/IN GE: F26DBX, SYLVANIA: CF26DD/E GE: F26TBX, SYLVANIA: CF26DT/E/IN GE: F32TBX, SYLVANIA: CF32DT/E/IN GE: F42TBX, SYLVANIA: CF42DT/E/IN GE: F57TBX, SYLVANIA: CF57DT/E/I GE: F70TBX, SYLVANIA: CF70DT/E/IN
2 lamps
600 675 600 675 600 950 600 950 725 1200 725 1200 1050 1250 1300 N/A 1160 N/A 1200 N/A
Bodine B94C-2-2
IOTA I42EM-J
When ordering trims for INTG 750, INTG 1300 or INTG-D-750 emergency options, place “INTG” at the end of the trim catalog number. E.g. 6501-WH-INTG
IOTA I42EM-R-J
www.maxilume.com • tel: 1-877-375-5555 • fax: 1-877-375-333
117
product index catalog number page
catalog number page
catalog number page
1101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4607 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4614 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4615 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6522 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6523 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6524 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6526 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6527 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
1115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6705 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6706 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6707 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6708 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
1513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6709 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6710 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
1515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
6116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6711 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87
6117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87
6118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32,87
6119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6714 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6717 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6718 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6719 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88
6501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6726 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6727 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 87
6508 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 87
6509 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
4121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
8104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 8105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
8106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88
6513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88
6514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 88
6515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32, 88
6516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
8112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
118
www.iuseelite.com • www.maxilume.com
product index catalog number page
catalog number page
catalog number page
8113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8708 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B473 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
8114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8709 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B4CF-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
8115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8710 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B4PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
8116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8711 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B4PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
8117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8713 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8119 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8714 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8715 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8716 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8717 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8718 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8719 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B535 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B541 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8501 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B542 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B565 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B5PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
8504 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8726 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B5PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
8505 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8727 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
B5PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
8506 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2W-T418-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16
B5PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
8507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2W-T426-120-1-S . . . . . . . . . . . . . . . . . . . . . . 16
B601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
8508 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
2W-T426-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16
B605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
8509 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
2W-T432-120-1-S . . . . . . . . . . . . . . . . . . . . . . 16
B620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8510 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
2W-T432-120-2-S . . . . . . . . . . . . . . . . . . . . . . 16
B6PL-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
8511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
AF632 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
B6PLIC-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
8512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
AF640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
B6PLIC-32-E . . . . . . . . . . . . . . . . . . . . . . . . . . 104
8513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
AYF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B6PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
8514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
AYF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . 20
B6PLR-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
8515 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
B36PLIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
B6PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8516 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
B36PLRIC-E . . . . . . . . . . . . . . . . . . . . . . . . . . 111
B701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
B391 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
B702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8518 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
B397 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
B703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8519 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
B401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8521 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B705 . . . . . . . . . . . . . . . . . . . . . . . . . . . 106, 108
8522 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B706 . . . . . . . . . . . . . . . . . . . . . . . . . . . 106, 108
8523 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B707 . . . . . . . . . . . . . . . . . . . . . . . . . . 107, 1083
8524 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B721 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8525 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B437 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8526 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B438 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
8527 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
B439 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
B723 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 B724 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B444 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
B725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B451 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
B729 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8703 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B452 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
B731 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B454 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B735 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
8705 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B455 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
8706 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B462 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B737 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
8707 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
B471 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
B741 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
www.iuseelite.com • www.maxilume.com
119
product index catalog number page
catalog number page
catalog number page
B742 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
FDB-T442-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15
MSCF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . 21
B743 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
FDB-T442-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15
NF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B751 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
GRX-310 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NF-10-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B752 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
GRX-IT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B753 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
GRX-IT-WH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B754 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
HH10PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
NFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
B755 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
HH4SQPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
NTF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B756 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
HH6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
NTF-10-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B757 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HH6PLIC-AT . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
NTF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B758 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HH8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
NTF-103-P-277 . . . . . . . . . . . . . . . . . . . . . . . . 20
B759 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HHJ6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
NTFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
B760 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HHJ8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
QSG-P120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
B780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HHR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
RTA-RX-F . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22
B781 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HHR8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
RTA-TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
B782 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HS6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
RTA-WX . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22
B785 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HS8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
RTZ-TX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
B787 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HV10PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B788 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HV4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SF-10P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B789 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HV4PLIC-AT . . . . . . . . . . . . . . . . . . . . . . . . 29, 86
SF-12P-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B796 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
HV6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
SF-12P-277-3 . . . . . . . . . . . . . . . . . . . . . . . . . . 20
B84CG-2-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
HV8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
SFTU-5A3P . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
B94C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
HVJ4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SPS-4IT-RP . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22
BDL94C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
HVJ6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
SPSF-6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
BHHR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
HVJ8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
SPSF-6A-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 21
BHVR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
HVR4PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
SPSF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DVF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
HVR6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
SPSF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . . 21
DVF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . . . 20
HVR8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
SPSFTU-5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DVFTU-5A3P . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
HW6PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
VF-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DVSCF-103P . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
HW8PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
VTF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DVSCF-103P-277 . . . . . . . . . . . . . . . . . . . . . . . 20
I-42 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
EMG 1300 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
I420-EMA-R . . . . . . . . . . . . . . . . . . . . . . . . . . 114
EMG 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
I-42-DL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
EMG-D 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
ICE-420-EM-A . . . . . . . . . . . . . . . . . . . . . . . . . 115
FDB-T418-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14
INTG 1300 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
FDB-T418-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14
INTG 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
FDB-T418-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15
INTG-D 750 . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
FDB-T418-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15
LXF-103PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
FDB-T426-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14
LXF-103PL-277 . . . . . . . . . . . . . . . . . . . . . . . . 20
FDB-T426-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14
MAF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T426-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15
MAF-6AM-277 . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T426-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15
MA-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T432-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14
MA-R-277 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T432-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14
MSCA6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
FDB-T432-277-1-S . . . . . . . . . . . . . . . . . . . . . . 15
MSCA8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
FDB-T432-277-2-S . . . . . . . . . . . . . . . . . . . . . . 15
MSC-AD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T442-120-1-S . . . . . . . . . . . . . . . . . . . . . . 14
MSC-AD-277 . . . . . . . . . . . . . . . . . . . . . . . . . . 21
FDB-T442-120-2-S . . . . . . . . . . . . . . . . . . . . . . 14
MSCF-6AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
120
www.iuseelite.com • www.maxilume.com
sales agreement, terms and conditions General ACCEPTANCE/GOVERNING TERMS: These Terms and Conditions of Sale (“Agreement”) shall apply to all sales of products by Elite Lighting Inc., a corporation of the State of California. As used in these Terms and Conditions of Sale, “we” and “our” shall refer to Elite Lighting. Unless otherwise specifically agreed in writing by an authorized representative of Elite Lighting, any different or additional terms and conditions proposed by any customer in a purchase order, response to a quotation, or other proposal are hereby rejected by Elite Lighting and shall not be incorporated into the agreement for sale of Elite Lighting products. Customer’s assent to these Terms and Conditions of Sale shall be conclusively presumed from customer’s ordering products quoted by Elite Lighting, customer’s failure to object in writing to these Terms and Conditions of Sale, and/or customer’s acceptance of all or part of any products ordered. If Elite Lighting is found to have acknowledged customer’s order or proposal, and such acknowledgement constitutes an acceptance of an offer , such acceptance is expressly made conditional on customer’s assent solely to these Terms and Conditions of Sale, which shall form part of the acknowledgement, and acceptance by customer of any products shall be deemed to constitute such assent. If any quotation or other document of Elite Lighting is deemed to constitute an offer to customer, customer’s acceptance of such offer is limited to these Terms and Conditions of Sale.
Elite Lighting in writing and received prior to shipment of the order. Verbal order cancellations will not be
TERMS OF PAYMENT Terms Terms of payment for all of Elite Lighting products are as follows: All invoices must be paid within 30 days of invoice date. An additional fee of 2% per month or the highest lawful rate under applicable state law will be charged by Elite Lighting on all invoices which are past due. Should it be necessary for Elite Lighting to institute formal collection proceedings to collect any past due amounts from customer, Elite Lighting shall be entitled to recover its attorney’s fees and other costs associated with the proceedings. Notwithstanding the acceptance of any order by Elite Lighting, we reserve the right not to ship material to any customer not paying in accordance with our terms or who, in the sole opinion of Elite Lighting, may be unable to meet its payment obligations to Elite Lighting.
STANDARD PACKAGE POLICY AND/OR “BROKEN CARTON” CHARGE Elite Lighting will ship the order as written, but it will apply a broken carton charge of $5.00 to each catalog number so ordered which is not in box quantity.
FREIGHT TERMS Freight will be prepaid and allowed by Elite Lighting on any order totaling $2,000 or more within the limits of the continental United States. Orders not qualified for prepaid freight will be shipped with transportation charges prepaid by Elite Lighting and added to customer’s account, unless other method is requested by the customer. Partial shipments will be made at the discretion of the customer, provided the customer pays excess freight. When Elite Lighting bears the cost of shipment, we reserve the right to ship all orders in one complete shipment. Partial shipments may be made at our discretion. Elite Lighting will not be responsible for storage charges or cartage charges beyond the destination address acknowledged by Elite Lighting. All shipments will be made via carrier selected by Elite Lighting reserves the right to choose origin of shipment and routing. DIRECT SHIPMENTS Elite Lighting reserves the right to refuse the request of any distributor to make direct shipments of products to any destination outside the regular or assigned sales and service area of the distributor. MERCHANDISE AND CLAIMS TERMS Unless otherwise noted, sales of Elite Lighting Products will be F.O.B. factory. Title and risk of loss to all products shall pass from Elite Lighting to our customers upon execution of a bill of lading or tender of freight to carrier’s agent or customer’s agent, whichever shall first occur. When shipments of Elite Lighting products are to be made via company truck, title and risk of loss to the products shall pass to our customers at time of delivery to the final destination or to the forwarding carrier. All claims for loss or damage in transit must be made by customer to both the carrier and Elite Lighting within 5 working days. DATE OF SHIPMENT Shipping dates are approximate and are based on conditions existing at the time of Elite Lighting’s receipt of customer’s firm order and full information. Elite Lighting will in good faith endeavor to ship by the estimated shipping date but it shall not be responsible for any delay or any damage arising there from. RETURN MERCHANDISE TERMS No merchandise shall be returned by the customer without prior written consent and authorization in the form of a Return Goods Authorization (RGA), which has been issued by Elite Lighting expressly for the merchandise to be returned. This RGA will be issued at the sole discretion of Elite Lighting and must be requested by the customer within 90 days of the original shipment date. Returned merchandise must be in its original sealed cartons. All returned merchandise must be in salable condition in order to qualify for credit. No special products, nonstocking products, custom-made products, outdated or modified versions of cataloged factory stocking items may be returned by the customer. Except for products considered by Elite Lighting to be defective in workmanship or materials, all returns will be subject to a minimum 35% handling and factory inspection charge, and a deduction will be made for the freight expense of the original shipment. Merchandise accepted for return must be shipped prepaid to the factory or other destination specified by Elite Lighting. ORDER CANCELLATION TERMS Elite Lighting will accept order cancellations from customers only if the cancellations are sent to
accepted. Cancellation charges shall be those costs incurred by Elite Lighting, but not less than 10% of the value of an order. All costs for warehousing and freight on orders cancelled after shipment and/or refused at destination will be charged to the customer. Elite Lighting reserves the right to impose on the customer an additional charge of 25% of the value of an order if the order is cancelled after it has been processed for shipment. MINIMUM ORDER CHARGE A service charge of $20.00 will be added to all original customer orders, which total less than $100.00 net. PRICING Prices are subject to change without notice. Elite Lighting will ship merchandise at prices prevailing at the time of shipment. Prices are exclusive of sales, use, excise or similar taxes unless otherwise noted.
SPECIFICATIONS Elite Lighting in no way, express or implied, accepts responsibility for voltage determination. Elite Lighting shall not be responsible for quotations of prices or specifications concerning non-catalogued products unless Elite Lighting confirms this to the customer in writing. Catalogued items are those listed in Elite Lighting’s current price sheets. Dimensions of fixtures color modifications are subject to change without notice. Unless specifically agreed by Elite Lighting in writing, we do not warrant compliance of our products with individual project specifications. ERRORS Typographical or clerical errors in quotation orders or acknowledgments are subject to correction. DIMENSIONS The dimensions in catalogs and price lists are normally accurate, but are not to be used for construction purposes. CHANGES IN PRODUCT DESIGN Elite Lighting reserves the right to change, discontinue or modify the design and construction of any of its products and to substitute material equal to or superior to that originally specified. Conditions of Sale WARRANTY AND OBLIGATIONS THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT BY WAY OF LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Elite Lighting warrants that products sold will, upon shipment, be free of defects of workmanship or material under normal and proper usage. Should any failure to conform to this warranty become apparent during the warranty period (in most cases three years after the date of shipment) Elite Lighting must be notified in writing. Elite Lighting is not responsible for labor costs in connection with the installation, removal or replacement of warranted products or for any consequential damages. Elite Lighting further reserves the right to refuse to honor the above warranty for any product(s) altered, improperly installed in application for which not intended. In no event and under no circumstances shall Elite Lighting be liable to the purchaser or to any other person for any indirect, special, consequential or incidental losses or damages including, without limitation, lost profits except to the extent that liability for personal injury or property damage may be imposed upon Elite Lighting by law. As used herein, the term “person” shall include, without limitation, any individual, sole proprietorship, partnership, corporation or other entity. This warranty does not apply to Elite Lighting products which have been altered or repaired outside of Elite Lighting’s factory or which have been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty also does not apply to products not manufactured by Elite Lighting. Elite Lighting manufactures neither fluorescent ballasts, photoelectric controls nor lamps. Any warranty regarding such components is made by the manufacturer of the components, and customer shall direct all claims to the component manufacturer. LIMITATION OF LIABILITY IN NO EVENT SHALL ELITE LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE) NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF ELITE LIGHTING FOR ANY CLAMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THIS AGREEMENT OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF THE PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF THE PRODUCTS. THIS LIMITATION OF LIABILITY SHALL APPLY TO ANY LIABILITY FOR DEFAULT UNDER OR IN CONNECTION WITH THE PRODUCTS, PARTS, OR SERVICES DELIVERED HEREUNDER WHETHER BASED ON WARRANTY, FAILURE OF OR DELAY IN DELIVERY, OR OTHERWISE.
www.iuseelite.com • www.maxilume.com
121
• Architectural Downlighting • Residential Downlighting • Exit & Emergency Lighting • Linia Cove Lighting System • Undercabinet Lighting • Track Lighting • Ropelighting • Step Light
The products shown in this catalog are covered by USA and international patents. Specifications are subject to change without notice. elite lighting reserves the right to make any changes in the design, construction and listing approval of the products listed in this catalog which may be required by law or by the rules of any regulatory body or at its discretion. All information within this catalog is accurate at time of printing. Dimensions and specifications are subject to change without prior notice. Not responsible for any typographical error. Some pictures provided by: Peter Brentlinger. Not all lighting products shown in the pictures are manufactured by Elite Lighting. Wattage and specifications maybe different for products supplied in Canada. © Copyright 2009. Elite Lighting. All Rights Reserved.
main office: Los Angeles, CA Tel: 1-323-888-1973 / 1-877-375-5555 Fax: 1-323-888-1977 / 1-877-375-3333 www.iuseelite.com • www.maxilume.com
www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road, Coopersburg, PA 18036-1299 World Headquarters 1.610.282.3800 Barcelona I Beijing I Berlin I Chicago I Dubai I Hong Kong I London I Los Angeles I Madrid I Mexico City I New York I Paris I São Paulo I Shanghai I Singapore I Tokyo I Toronto Technical Support Center 1.800.523.9466 I Customer Service 1.888.LUTRON1