Descripcion trituradora franklin

Page 1

GRINDER PUMPS GP SERIES

APPLICATIONS • Low pressure sewer applications • Sewage wastewater transfer for light commercial or residential applications

FEATURES • Patented cutting system providing tight cutting clearances for superior cutting action grinding 414,000 cuts per minute • Single-phase, capacitor start/run motor with built-in overload protection against over-current and over-temperature damage • Brass 7-vane, angled face, non-clogging and balanced designed impeller • Case hardened to 60 HRc 440 stainless steel cutter system – Anti-roping design – Field replaceable • Upper and lower ball bearings • 140 °F (60 °C) liquid temperature rating • GP-M grinder pumps require control panel or capacitor kit specifically matched to pump for proper operation and third-party approvals • Compact and easier to lift only 75 lbs (34 kg)

GP-M

SERIES SPECIFICATIONS Volts

Amps

Hz FLA

Performance (GPM @ Height in Feet)

Watts Start

20'

40'

60'

80'

100'

120'

Shut-Off (ft)

PSI

208

60

13.9

68

3200

32

31

30

25

20

10

130

56

230

60

13.9

65

3200

32

31

30

25

20

10

130

56

Item No.

Model

HP

Volts

Switch Type/ Operation

On Level

Off Level

Cord

Weight

520865

GP-M231-15

2

230

Manual

15' 4.6 m

81 lbs 36.74 Kg

2 HP