MER_509590_in_en

Page 1

© Merten2005V5095-582-0101/10

en

ARGUS an Fernbedienung anlernen

Fernbedienung für Funk-ARGUS 220 CONNECT Gebrauchsanleitung

Es können max. 4 Funk-ARGUS 220 CONNECT an die Fernbedienung angelernt werden.

|

Dabei gilt: Pro Taste immer nur 1 ARGUS!

Funk-ARGUS im Funksystem CONNECT Durch die Verbindung mehrerer ARGUS 220 CONNECT im Funk-System lässt sich ein optimaler Schutz erreichen, da immer alle Bewegungsmelder und die daran angeschlossenen Verbraucher aktiviert werden, egal welcher Bewegungsmelder aktiviert wurde.

|

FUNCTION IDENT

BIND

CLEAR

ARGUS SELECT

A2

A3

ON

OFF

A1

AUTO

A4

SET

-30s

+30s

+

SET

FUNCTION IDENT

BIND

merten

CLEAR

ARGUS identifizieren

ARGUS SELECT

A1

A2

A3

AUTO

ON

OFF

A4

IDENT

BIND

AUTO

-30s

A2

A3

ON

OFF

A2

A1

A4

A1

+

+30s

A2 A3

A3?

Z-Wave Begriff Inclusion

CLEAR

ARGUS SELECT

A1

+30s

Verwendung Association Group = 1 Parameter = 0 Association Group = 2 Parameter = 1 Association Group = 3 Parameter = 2 Association Group = 4 Parameter = 3

A4

1

FUNCTION

SET

SET

Sollten Sie einen oder mehrere Funk-ARGUS neu einstellen wollen, können Sie den jeweiligen ARGUS einfach über die Fernbedienung identifizieren.

1

SET

-30s

|

Taste A1

A2

+

SET

merten

merten

FUNCTION IDENT

BIND

2

CLEAR

ARGUS SELECT

Art.-Nr. 509590

A1

A2

A3

AUTO

ON

OFF

A4

SET

-30s

SET

+30s

+

merten

2

6s

BIND

Exclusion

A3

FUNCTION IDENT

CLEAR

ARGUS SELECT

A1

AUTO

A2

A3

ON

OFF

A4

SET

BIND

=

Notwendiges Zubehör

A1

A1

3x

merten

AUTO

-30s

FUNCTION

A2

ON

BIND

+

A3 A4

F

merten A Auswahl: Funktion B Auswahl: ARGUS 1 - 4 C Auswahl: Betriebsmodus D Einstellung: Helligkeit E Einstellung: Nachlaufzeit F Einstellung: Empfindlichkeit

A4

+

CLEAR

OFF

+

A3

OFF

FUNCTION

SET

E

+30s

+30s

-30s

ARGUS SELECT

D

SET

CLEAR

A2

ON

+30s

merten

5

Fernbedienung löschen

2

1

1 [BIND] Taste 3x schnell drücken: Fernbedienung ist im Lern-Modus.

„A“ D

B C

2

1

Wiederholen Sie die Schritte 1 - 5 bei jedem weiteren ARGUS, der an die Fernbedienung angelernt werden soll.

ARGUS über Fernbedienung einstellen

|

Mit der Fernbedienung kann man den ARGUS bequem und einfach einstellen.

BIND

A1

CLEAR

ARGUS SELECT

A1

A2

A3

AUTO

ON

OFF

SET

+

Fernbedienung über PC-Tool konfigurieren

merten

4 =

|

1

1 Konfigurieren Sie das Funksystem mit allen Komponenten am PC.

2

10 s 1

2

Wenn der zweite Funk-ARGUS auch den ersten schalten soll, muss zusätzlich noch die Verbindung in die entgegengesetzte Richtung durchgeführt werden. Gleiches gilt für jeden weiteren Funk-ARGUS.

|

Stellen Sie per Knopfdruck einen der folgenden Status ein:

Verbindungen löschen

2 [OFF] Tatse drücken: Der ARGUS ist permanent ausgeschaltet (Dauer AUS). 3 [AUTO] Taste drücken: Bei einem bereits eingeschalteten ARGUS wird die Nachlaufzeit gestartet. Ansonsten bleibt der ARGUS solange aus, bis eine Bewegung erkannt wird.

4

1 FUNCTION IDENT

BIND

A1

CLEAR

ARGUS SELECT

A1

A2

A3

AUTO

ON

OFF

A4

SET

-30s

+30s

+

SET

merten

2 =

CLEAR

Empfindlichkeit einstellen 1 Regler F am ARGUS aus Maximum einstellen. 2 [SET] Taste drücken: ARGUS blinkt schnell = Einlern-Modus aktiviert. Danach innerhalb von ca. 10 s einmal durch den Sensorbereich des ARGUS laufen: Die Empfindlichkeit des ARGUS wird so eingestellt, dass die gemessene Bewegung erkannt wird. Mit der [+] und [-] Taste kann der Wert nachträglich verändert werden.

1

4

Merten GmbH, Lösungen für intelligente Gebäude, Service Center, Fritz-Kotz-Str. 8, Industriegebiet BomigWest, D-51674 Wiehl Telefon: Telefax: E-Mail: Internet:

+49 2261 702-204 +49 2261 702-136 servicecenter@merten.de www.merten.de

Bei technischen Fragen wenden Sie sich bitte an unsere InfoLine:

Technische Daten Kanäle: Frequenz: Batterie: Anzeigeelemente: Reichweite:

Z-wave device type:

1 [SET] Taste drücken: der aktuelle Helligkeitswert wird übernommen.

1 [+30] oder [-30] Taste drücken: die aktuelle Nachlaufzeit wird pro Knopfdruck um 30 s verkürzt oder verlängert.

2 [BIND] Taste 3x schnell drücken: Fernbedienung ist im Lern-Modus: - LED blinkt rot: Fernbedienung ist Teilnehmer (Secondary) - LED leuchtet rot: Fernbedienung ist Systemverwalter.

Bei Warenrücksendungen auf Grund von Beanstandungen wenden Sie sich bitte an unser Service Center:

4 868 MHz, Z-Wave 1 Lithium Knopfzelle (CR 2450N) LEDs Freifeld: bis zu 100 m Im Gebäude: bis zu 30 m

Telefon: +49 1805 212581* oder +49 800 63783640 Telefax: +49 1805 212582* oder +49 800 63783630 E-Mail: infoline@merten.de *kostenpflichtig/fee required

Hinweise für versierte Anwender, die dieses Gerät mit Z-Wave kompatiblen Geräten anderer Hersteller verwenden möchten:

2

1

Helligkeitsschwelle einstellen

Schaltdauer einstellen

Merten GmbH

+30s

Betriebsart einstellen

1 [ON] Tatse drücken: Der ARGUS ist permanent aktiv, unabhängig von Bewegungen (Dauer AN).

A2

A4

SET

-30s

Dieses Gerät kann mit allen Z-Wave-kompatiblen Geräten verwendet werden; auch mit Geräten anderer Hersteller. Jedes Z-Wave-kompatible Gerät kann zu einem Z-Wave System hinzugefügt werden und funktioniert dann auch als Router sofern das Weiterleiten von Befehlen unterstützt wird. Die Konfiguration eines Z-Wave-Systems ist in der Beschreibung der Geräte mit Systemverwaltung (z. B. Funk-Taster CONNECT) beschrieben. Einige Funktionen sind nur mit Geräten möglich, die zum Funk-System CONNECT kompatibel sind.

2 [BIND] Taste 1x lang drücken bis eine LED (A1...A4) auf „Grün“ umschaltet: Fernbedienung ist gelöscht.

3 BIND

FUNCTION IDENT

Die Fernbedienung bekommt den Status „Systemverwalter“, solbald der erste ARGUS angelernt wurde.

B C

SET

IDENT

OFF

merten

ON

A1

AUTO

A4

-30s

A3

SET

=

SET

A

ARGUS SELECT

-30s

ARGUS mit ARGUS verbinden AUTO

FUNCTION

BIND

ARGUS SELECT

A1

10 s

– Bewegungsempfindlichkeit

Anschlüsse, Anzeigen und Bedienelemente

IDENT

A2

+

SET

|

– Schaltdauer

A2

OFF

+30s

AUTO

– Betriebsart (Dauer AN, Dauer AUS, Automatik) – Helligkeitsdauer

A2

ON

SET

SET

IDENT

Folgende Funktionen lassen sich über die Fernbedienung am ARGUS einstellen:

A2

CLEAR

C

Diese Fernbedienung ist nur für den Gebrauch mit dem Funk-ARGUS 220 CONNECT, fernbedienbar vorgesehen.

A1

BIND

ARGUS SELECT A1

„B“

D

Fernbedienung kennen lernen

CLEAR

|

FUNCTION IDENT

4

BIND

3

A3

A

– Funk-ARGUS 220 CONNECT (Art.-Nr. 509519/ 509560)

IDENT

Primary

+

A1

A4

3

+30s

-30s

SET

CONNECT Begriff Anlernen (sendet Node Info Frame), siehe Beschreibung Funksystem CONNECT Zurücksetzen in den Anlieferungszustand, Auslernen Gerät mit Systemverwaltung

2

Controller (nur Secondary Controller, das Gerät kann kein Primary sein) Dreifachklick auf BIND Taste. LED blinkt ca. 6 s

Learn -Mode: (für Einbindung in Z-Wave System anderer Hersteller) Transmit “Node info frame”: Dreifachklick auf BIND Taste. Warten bis die LED erlischt.

| 4

1

2

1

2

V5095-582-01 01/10

de


Teaching the ARGUS for use with remote control

de

en

Remote control for radio ARGUS 220 CONNECT

A maximum of 4 radio ARGUS 220 CONNECT can be taught on the remote control.

|

Radio ARGUS in the CONNECT radio system Optimum protection is achieved by connecting several ARGUS 220 CONNECT movement detectors in a radio system, as all movement detectors and loads connected to them are always activated, regardless of which movement detector was activated.

|

Following is acceptable: Only 1 ARGUS per push-button!

Operating instructions FUNCTION IDENT

BIND

CLEAR

ARGUS SELECT

FUNCTION

AUTO

IDENT

BIND

A2

A3

ON

OFF

A1

CLEAR

A4

Identifying ARGUS

|

If you should want to reprogramme one or several radio ARGUS movement detectors, you can simply identify the respective ARGUS device via remote control.

A3?

Z-wave designation Inclusion

+

SET

merten A3

AUTO

ON

OFF

A4

1

SET

-30s

A1

+30s

A2

FUNCTION IDENT

BIND

CLEAR

A1

+

AUTO

A2

A3

ON

OFF

A2

A1

ARGUS SELECT

SET

A3

A4

2

SET

-30s

merten

+30s

+

SET

merten FUNCTION IDENT

Art. no. 509590

BIND

IDENT

A3

OFF

A1

A2

A3

ON

OFF

Exclusion

A4

SET +30s

+

2

Necessary accessories

merten

A1

A1

A4

A3

IDENT A

FUNCTION IDENT

BIND

CLEAR

ARGUS SELECT A1

A2

A2

ON

OFF

A2

SET

-30s

„B“

D

ARGUS SELECT

A1

AUTO

-30s

SET

Connecting ARGUS with another ARGUS

+

A3

CLEAR

OFF

A4

5

2

1

|

The remote control has the status "System administrator" as soon as the first ARGUS has been taught.

BIND

A1

CLEAR

ARGUS SELECT

A1

A2

A3

AUTO

ON

OFF

3 A2

A4

SET

-30s

SET

+30s

+

merten

Repeat steps 1 - 5 for each additional ARGUS to be taught on the remote control.

Setting up the ARGUS via remote control

FUNCTION

A2

A3

AUTO

ON

OFF

A4

SET

+

Setting the operating mode

D

Use the buttons to select one of the following statuses:

merten A Selection: Function mode B Selection: ARGUS 1 - 4 C Setting: ARGUS operating mode D Setting: Brightness E Setting: Overshoottome F Setting: Sensitivity

1 Press the [ON] button: The local ARGUS is permanently active, regardless of whether or not movement is detected (permanent ON).

1

2

1

2

2 Press the [BIND] push-button quickly 3x: The remote control is in programming mode: - The red LED is flashing: the remote control is the device (Secondary) - The red LED is illuminated: the remote control is the system administrator.

10 s

When the second radio ARGUS is also to switch the first device, a connection must also be made back in the opposing direction. This applies to each additional radio ARGUS.

|

C

F

|

It is quite simply and confortable to configure the ARGUS with the remote control.

B

E

+30s

|

Deleting connections

2 Press the [OFF] button: The local ARGUS is permanently switched off (permanent OFF). 3 Press the [AUTO] button: .f the ARGUS is already on, the overshoot time is started (automatic mode). Otherwise the ARGUS remains off until a movement is detected.

4

1 FUNCTION IDENT

BIND

A1

CLEAR

ARGUS SELECT

A1

AUTO

A2

A3

ON

OFF

A4

SET

-30s

+30s

+

SET

merten

2 =

CLEAR

Setting the sensitivity

1

4

2

|

1 Controller F at the ARGUS at maximum. 2 Press the [SET] button: ARGUS flashes fast: Teaching mode activated . Then, run across the sensor range of the ARGUS once within approx. 10 s. The sensitivity of the ARGUS is set such that the measured movement is detected. You can alter this value afterwards using the [+] and [-] buttons.

Technical data Channels: Frequency: Battery: Display elements: Range:

Merten GmbH, Solutions for intelligent buildings, Service Center, Fritz-Kotz-Str. 8, Industriegebiet BomigWest, D-51674 Wiehl Phone: Fax: E-Mail: Internet:

+49 2261 702-204 +49 2261 702-136 servicecenter@merten.de www.merten.com

If you have technical questions, please contact our InfoLine: Phone: +49 1805 212581* or +49 800 63783640 Telefax: +49 1805 212582* or +49 800 63783630 E-Mail: infoline@merten.de *fee required

4 868 MHz, Z-wave 1 lithium button cell (CR 2450N) LEDs Free field: up to 100 m Indoors: up to 30 m

Z-wave device type:

1 Press the [SET] button: the current brightness value is adopted.

1 Press the [+30] or the [-30] button: the current overshoot time is reduced or increased by 30 s per push of the button.

This device can be used with all Z-wave compatible devices, including devices from other manufacturers. Each Z-wave compatible device can be added to a Z-wave system and then also acts as a router, if the routing of commands is supported. Configuration of a Z-wave system is described in the description of devices with system administration function (e.g. CONNECT radio push-button). Some functions are only possible with devices which are compatible with the CONNECT radio system.

Information for experienced users who want to use this device with Z-wave compatible devices from other manufacturers:

2

1

Setting the brightness threshold

Setting the switching duration

Configuring the remote control via PC tool 1 Configure the radio system using all the components on the PC.

4 =

|

Merten GmbH

BIND

FUNCTION IDENT

Teach (transmits Node info frame), see CONNECT radio system description Reset to factory settings; complete programming Device with system administration

2 Press and hold down the [BIND] push-button 1x until an LED (A1...A4) turns green: The remote control has been cleared.

B C

– Sensitivity

ARGUS SELECT

A4

+

1 Press the [BIND] push-button quickly 3x: The remote control is in programming mode.

2

1

„A“ D

– Switching duration

A1

A3

OFF

Clearing the remote control

FUNCTION

A2

ON

BIND

+30s

ARGUS SELECT

merten

A1

-30s

SET

SET

AUTO

IDENT

=

You can set the follwing functions at the ARGUS via the remote control:

A

A2

ON

+30s

merten

10 s

This remot control is only for usage with Radio ARGUS 220 CONNECT, remote-controlled.

CLEAR

CLEAR

SET

Getting to know the remote control

Connections, displays and operating elements

BIND

+

C

4

– Brightness threshold

FUNCTION

+30s

IDENT SET

CONNECT designation

3

A1

AUTO

– Radio ARGUS 220 CONNECT (Art. no. 509519/ 509560)

BIND

+

SET

Primary

=

3x 3

+30s

-30s

6s BIND

-30s

CLEAR

A4

AUTO

-30s

merten

SET

BIND

ARGUS SELECT A2

ON

SET

SET

IDENT

A3

FUNCTION CLEAR

ARGUS SELECT

A1

AUTO

– Operating mode (permanent ON, permanent OFF, automatic mode)

Application Association Group = 1 Parameter = 0 Association Group = 2 Parameter = 1 Association Group = 3 Parameter = 2 Association Group = 4 Parameter = 3

+30s

-30s

A2

A2

A4

1

SET

ARGUS SELECT

A1

Push button A1

4

1

2

1

2

Controller (the Secondary Controller only, this device cannot be a primary device) Learn -Mode: Triple click on BIND push(for integration into Z-wave button. LED flashes apsystems of other manufac- prox. 6 seconds turers) Transmit “Node info frame”: Triple click on BIND pushbutton. Wait until the LED goes out. V5095-582-01 01/10

© Merten2005V5095-582-0101/10


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.