Preformed Copper Applications

Page 1

Quick Product Reference Guide for Copper Applications RUS Listed Products

Buried Service Wire Closures

Splice Count

PLP Part Number

Description

6

Ranger SERVISEAL® Closure 6 Pair Drop Provides long-term protection for buried service wire

8006137

12

Super SERVISEAL® Closure 12 Pair Drop Provides long-term protection for buried service wire in a larger size

8006039

25

BLACK-JACKTM 25 Pair Butt Splice* Closures are filled with POLY-BEETM Sealant to provide long-term protection for direct buried cable splices. The sealant is designed to form a barrier to protect splices against the harsh elements of nature.

8006318

25

BLACK-JACKTM 25 Pair* Available in In-Line or Butt Splice

8006508

50

BLACK-JACKTM 50 Pair In-Line or Butt Splice Incorporates both capabilities: In-Line or Butt Splice

*Based upon 22-26 ground wire

8006681

ARMADILLO® Stainless Kits include top and bottom shell halves, LOCK-BARTM Assemblies, Torque Bars and two 2-section End Plate kits (except 3-section End Plates with 12.5"). Bonding kit includes shield connectors, pair protectors and bonding braid. C-Cement, not included in kit, is sold separately and required. PLP Part Numbers

Armadillo® Stainless Shell Splice Case Kits

Splice Count

Encapsulated

Recommended Size

Armadillo® Stainless Kits with Drillable End Plates and bonding

Filling Flange Kit with Drillable End Plates, and bonding

Recommended RD Encapsulant Amount (grams)**

Encapsulant Ordering Guide PLP Part Numbers

Nominal Kit Net Wt. (grams)

80802437

600

80802820

750

80802438

1200

80802821

1500

80802822

2600

80802439

3000

50 thru 200

4" x 25"

8000624

8006366

3,800

300 thru 600

6.5" x 22"

8006326

8006429

8,000

300 thru 1100

6.5" x 28"

8000626

8006367

11,000

900 thru 1500

6.5" x 38"

8000634

8006369

16,000

900 thru 2100

8" x 28"

8006320

8006410

18,000

1200 thru 2400

8" x 38"

8006321

8006411

24,000

80802825

5000

1500 thru 2700

8" x 45"

8006322

8006412

30,000

80802823

6000

1500 thru 2700

9.5" x 28"

8000630

8006368

23,000

80802440

7800

1800 thru 3600

9.5" x 38"

8000635

8006370

33,000

80802826

8000

2100 thru 4200

9.5" x 45"

8006176

8006371

41,000

80802827

9000

2100 thru 4200

9.5" x 53"

8006668

8006701

46,000

2400 thru 3000

12.5" x 28"

8006219

8006372

39,000

2700 thru 3600

12.5" x 38"

8006220

8006373

57,000

3000 thru 4200

12.5" x 45"

8006221

8006374

69,000

3000 thru 4800

12.5" x 65" (Shell Kit Only) (2) 12.5" End Plates Required. Refer to 12.5" 3-Section End Plate

Call Tech Support

Call Tech Support

Call Tech Support

Consult Communications Catalog, page 10-21 for Re-enterable or Non Re-enterable Encapsulant for Buried Applications

**Based on 10% of closure volume being occupied by splice connectors. CO-SS-1067 03.10.1M


Quick Product Reference Guide for Copper Applications RUS Listed Products

Additional Armadillo Products PLP Part Numbers

Description

Three Section End Plate

Splice Case Coupler

C-Cement

Power End Plate Cutter and Case

6.5" 3-Section End Plate Kit, Drillable, can accomodate a variety of cables, cable sizes and cable configurations

8000361

8.0" 3-Section End Plate Kit, Drillable, can accomodate a variety of cables, cable sizes and cable configurations

8003110

9.5" 3-Section End Plate Kit, Drillable, can accomodate a variety of cables, cable sizes and cable configurations

800081098

12.5" 3-Section End Plate Kit, Drillable, can accomodate a variety of cables, cable sizes and cable configurations

8003055

6.5" ARMADILLO Splice Case Coupler, allows the joining of two 6.5" shell kits end to end, includes torque bars

8003089

9.5" ARMADILLO Splice Case Coupler, allows the joining of two 9.5" shell kits end to end, includes torque bars

8003031

4 oz. can C-Cement – required for both cable preparation and End Plate preparation, but is not supplied with Splice Cases or End Plate Kits. Must be ordered separately. Ground Shipment Only

80802377

Power End Plate Cutter and Case with Blade Kit

8000454

Tool Kit with Torque Wrench

8000428

Consult PLP Communications Catalog Section 10 for additional ARMADILLO Series Accessories and Vault Closure Ordering Selection.

Bonding Connectors

PLP Part Numbers

Description MORAYTM Shield Bond Connector Specially designed teeth penetrate the polymer coating on the cable shield to provide excellent pull-out strength and electrical pattern. Spring-Action top plate remain in contact with the sheild at all times. Design is flexible enough to handle the expansion and contraction of the cable sheath

8000745

MINI-MORAYTM Shield Bond Connector Reliable bonding harness for organizing telecommunications buried service wires. Same reliable design but with smaller diameter cables.

8000751

MULTI-BOND Shield Connector Reliable bonding harness for organizing telecommunications buried service wires. Designed to be used in multiple service distribution. Ships with bonding support plate, lug, clamps, five screws and nuts.

8003072

2 or 3 pair

SERVI-BOND Shield Connector Long neck, Armored and Non-armored – Designed to assure shield continuity to a point of ground for buried service wires

2 or 3 pair

SERVI-BOND Shield Connector 7" (177 mm) harness (floating hook terminal), Armored and Non-armored – Designed to assure shield continuity to a point of ground for buried service wires

8000733 (long neck) 8000739 (floating hook terminal)

s

For additional product info, contact your local PLP sales manager or visit preformed.com (See Territory Coverage Map)

© 2010 Preformed Line Products Printed in U.S.A.

s

For further assistance or Technical Support, call Preformed Line Products at

440.461.5200

Feature Focus Video available for Flash Testing the Armadillo Stainless Splice Case.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.