D i g i t a l c a re c o m m u n i c a t i o n system for hospitals and nursing homes


clino phon 21 opens new paths for care communication within hospitals and nursing homes setting standards for nurse call, patient-nurse communication and audio transmission, as well as TV and radio control. User-friendly terminals and components add value to staff and patients by their excellent and outstanding functionality and design. Specifically for centralized care concepts, clino phon 21

Easy handling, maximum comfort. offers first class digital communication, discreet and hands-free between the staff and patients. Using standard components and terminals the system can be extended to the multimedia communication system dlino com 21. Using the same general infrastructure and control units clino phon 21 offers a simple upgrade route for the service integrating clino com 21.


The interface bedside –

P Loudspeaker and microphone for

the bed electronic

digital handsfree individual speech

P Call button for the nurse call

per bed, in the case that a pear or

P Cancel button, offering the optional

multiple push button is used –

P

noise sensors

P

pneumatic call units e.g. for people affected in their mobility.

P 6-pole socket with galvanic

opportunity of cancelling the pending

the perfect solution not only within

separation according to EN 60950 for

call from bedside individually

centralized systems.

the connection of medical devices

P Autorelease socket for the

P 7-pole socket for the connection of

connection of the patient handset or

alternatively:

pear / multiple push buttons

P

parallel pear or multiple push buttons

such as infusion pumps etc.


System overview clino phon 21

Room bus

EDP

Ethernet Ward bus Nurse call server

Paging / DECT Room bus

Fire Detection

Backbone

P Standardized system interfaces

A large variety of system interfaces inte-

service, other security relevant systems

grate the care communication system

such as fire detection or intrusion alarm

(easy connection of non-propietary

clino phon 21 in the communication infra-

systems can be connected to clino phon 21.

systems such as IT, paging, DECT,

structure of its installation environment. In

Of course, call logging and call evaluation,

BMS....)

particular the cost for separate radio dis-

the graphical call indication on a central or

P Extensive network management tools

tribution can be saved because the cab-

local ward PC are part of the standard

(remote control, performant mainten-

ling of clino phon 21 already supports the

functionality of this comprehensive com-

ance and analysis tools)

distribution of up to 16 radio channels. The

munication system for professional care.

central radio source is fed into an audio interface of a data management processor and is converted into high-quality digital

System overview

radio signals for a high-class transmission.

P Hierarchic network structure

The data management processor is the

(room bus, ward bus, backbone)

central interface to the nurse call server

P Loop structure of the bus systems

and at the same time represents the cen-

(permanent function control of the

tral control unit for up to 2 wards.

components)

Together with the standard connection

P Small distances between the devices

options of paging and DECT systems for

allow plastic fibre cable (POF-cable)

the alarming of the medical or technical

for time saving installation


Especially adapted to the requirements

2 buttons for the channel search,

P Socket for headphone connection

of the patients – The patient handset

2 buttons for the loudness control,

P Shock protection by a surrounding

clino phon 21:

1 on/off button

P Big ergonomic call button with reassurance lamp and finding light P Clear structured function buttons – 2 light control buttons (yellow),

P Bipartite display for the indication of the actual TV or Radio channel, in off-status indication of the time P Loudspeaker and microphone for the

-one menu button to select the

discreet conversation between

function TV or radio control,

patient and staff

plastic frame and spash-proof (IP 54) to meet the special requirements of care environments P Auto-release plug for the protection of the connection cable in case of high pulling force


21.13GB/0403/3000 /fG Printed in Germany To the best of our knowledge, our publications are correct, but this does not render them legally binding. All rights reserved. Reproduction – in part or in whole – only with written permission. We reserve the right to make changes in line with technical progress.

Albert Ackermann GmbH + Co. KG Albertstraße 4–8 · D-51643 Gummersbach Telephone +49 22 61 83 361 · Fax +49 22 61 83 576 www.ackermann.com e-mail: clino@ackermann.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.