2007 circuit protection



Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today. From its base at Wythenshawe, through a policy of continuous design improvement, Wylex has developed a comprehensive range of Domestic, Commercial and Industrial circuit protection devices based on quality and close attention to the practical requirements of the contractor including the fundamental requirements of electrical safety embodied in the relevant British and International Standards including IEE Wiring Regulations.

Left Electrium’s purpose built Commercial Centre in Cannock, Staffordshire

N H I N S U L AT E D C O N S U M E R U N I T S

2

N H M E TA L C O N S U M E R U N I T S

6

CONSUMER UNIT MCBs RCBOs & FUSES

9

CONTROL MODULES

9

NH DISTRIBUTION BOARDS

10

DISTRIBUTION BOARD INCOMERS

13

DISTRIBUTION BOARD MCBs & RCBOs

14

N H M C C B PA N E L B O A R D S

16

PA N E L B O A R D N H G M C C B s

19

N H F U S E S W I T C H C O M B I N AT I O N U N I T S

20

N H I S O L AT O R S

21

S TA N D A R D R A N G E

22

LIFELINE RCDs & ENCLOSURES

26

S W I T C H D I S C O N N E C T O R S & I S O L AT O R S

30

T E C H N I C A L D ATA & D I M E N S I O N S

32

NUMERIC INDEX

44


THE NH RANGE The NH range of consumer units provides contemporary styling with particular attention to installation features including : ●

Generous cable preparation room with neutral and earth bars mounted on the top of the enclosure Supplied complete with incoming devices and fixed busbar system for speedy installation

Insulated versions with side entry cut outs profiled to accept mini trunking and large segmented rear cable entries to allow trimming to the precise cable entry size

Raised interior for maximum wiring space

Circuit identification labels providing clear understanding of outgoing ways


MAIN SWITCH CAT REF

MS RATING

MCB WAYS

40A 63A 100A 100A 100A 100A 100A 100A 100A 100A 100A

2 2 5 8 11 14 19 5 8 8 11

3 3 6 3

RCD RATING

MCB WAYS

DIN MODULES

40A 30mA 63A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 40A 100mA 63A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA TD* 100A 100mA TD* 100A 100mA TD* 100A 100mA TD* 100A 100mA TD*

2 2 5 8 11 14 19 2 2 5 8 11 14 19 5 8 8 11 5 8 8 11 5 8 11 14 19

NH804

With DIN Accessory Section

RCD INCOMER CAT REF

NH804+3

3

NHRS204/40 NHRS204/63 NHRS504 NHRS804 NHRS1104 NHRS1404 NHRS1904 NHRM204/40 NHRM204/63 NHRM504 NHRM804 NHRM1104 NHRM1404 NHRM1904 NHRS504+3 NHRS804+3 NHRS804+6 NHRS1104+3 NHRM504+3 NHRM804+3 NHRM804+6 NHRM1104+3 NHTM504 NHTM804 NHTM1104 NHTM1404 NHTM1904

3 3 6 3 3 3 6 3

With DIN Accessory Section

* Time Delay RCD

DUAL TARIFF 100A MAIN SWITCH AND 100A MAIN SWITCH CAT REF

NHRS504

NHIIX2404 NHIIX3304 NHIIX5404 NHIIX4504 NHIIX3904 NHIIX4804 NHIIX7504 NHIIX6604 NHIIX5704 NHIIX9804 NHIIX8904 NHIIX11604 NHIIX51204

MS RATING

MCB WAYS

MS RATING

MCB WAYS

100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

4 3 4 5 9 8 5 6 7 8 9 6 12

63A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

2 3 5 4 3 4 7 6 5 9 8 11 5

DUAL TARIFF 100A MAIN SWITCH AND 100A 30mA RCD MAIN SWITCH CAT REF

NHRSX5704 NHRSX6604 NHRSX7504 NHRSX8904 NHRSX9804

NHIIX6604

MS RATING

MCB WAYS

RCD RATING

MCB WAYS

100A 100A 100A 100A 100A

7 6 5 9 8

100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA

5 6 7 8 9

NH Insulated Range

NH204/40 NH204/63 NH504 NH804 NH1104 NH1404 NH1904 NH504+3 NH804+3 NH804+6 NH1104+3

DIN MODULES


SPLIT LOAD CAT REF

NH Insulated Range

4

NHRS4504

NHRS2404 NHRS3304 NHRS4204 NHRS5404 NHRS4504 NHRS3604 NHRS6304 NHRS3904 NHRS4804 NHRS6604 NHRS5704 NHRS7504 NHRS8404 NHRS9304 NHRS12504 NHRS11604 NHRS10704 NHRS61104 NHRS71004 NHRS9804 NHRS8904 NHRS51204

MS RATING

MCB WAYS

RCD RATING

MCB WAYS

100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

4 3 2 4 5 6 3 9 8 6 7 5 4 3 5 6 7 11 10 8 9 12

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

2 3 4 5 4 3 6 3 4 6 5 7 8 9 12 11 10 6 7 9 8 5

FLEXIBLE SPLIT LOAD CONSUMER UNITS CAT REF

NHRS6SL NHRS9SL NHRS12SL NHRS17SL

MS RATING MCB WAYS RCD RATING MCB WAYS MCB WAYS MIN MAX MIN MAX TOTAL

100A 100A 100A 100A

2 3 3 5

4 6 9 12

80A 30mA 80A 30mA 80A 30mA 80A 30mA

2 3 3 5

4 6 9 12

6 9 12 17

TIME DELAY FLEXIBLE SPLIT LOAD CONSUMER UNITS CAT REF

TD RCD

MCB WAYS RCD RATING MCB WAYS MCB WAYS MIN MAX MIN MAX TOTAL

NHSTM9SL 100A 100mA NHSTM12SL 100A 100mA NHSTM17SL 100A 100mA

3 3 5

6 9 12

80A 30mA 80A 30mA 80A 30mA

3 3 5

6 9 12

9 12 17

Flexible consumer units utilise a full DIN rail and accept modular DIN devices such as a Bell Transformer or Timer.

NHRS12SL

SPLIT LOAD WITH DIN RAIL ACCESSORY SECTION CAT REF

NHRS6504+6 NHRS5604+6 NHRS7704+3 NHRS8604+3 NHRS6804+3

MS RATING MCB WAYS

100A 100A 100A 100A 100A

5 6 7 6 8

RCD RATING

MCB WAYS

NO OF MODULES

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

6 5 7 8 6

6 6 3 3 3

SPLIT LOAD WITH TIME DELAY RCD INCOMER CAT REF

NHSTM4504

NHSTM3604 NHSTM4504 NHSTM5404 NHSTM6304 NHSTM3904 NHSTM4804 NHSTM5704 NHSTM6604 NHSTM7504 NHSTM8404 NHSTM9304 NHSTM12504 NHSTM11604 NHSTM8904 NHSTM9804 NHSTM10704 NHSTM71004 NHSTM61104 NHSTM51204

TD RCD

MCB WAYS

RCD RATING

MCB WAYS

100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA

6 5 4 3 9 8 7 6 5 4 3 5 6 9 8 7 10 11 12

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

3 4 5 6 3 4 5 6 7 8 9 12 11 8 9 10 7 6 5

A range of matching DIN enclosures is also available, see page 29.


INSULATED – DUAL SPLIT LOAD RCD CAT REF

NHISS5504 NHISS8704

ISOLATOR TOTAL No of A B RATING MCB WAYS RCD RATING MCB WAYS MS RATING MCB WAYS

100A 100A

10 15

80A 30mA 80A 30mA

5 7

80A 30mA 80A 30mA

5 8

100mA RCD available in either ‘A’ or ‘B’ section to order

5

IP65 CONSUMER UNITS WITH MAIN SWITCH CAT REF

MS RATING

NH304IP

63A

MCB WAYS

3

NH704IP

100A

7

NH1004IP

100A

10

IP65 CONSUMER UNITS WITH RCD INCOMER

NH704IP

CAT REF

MS RATING

MCB WAYS

NHRS304IP

63A 30mA

3

NHRS704IP

80A 30mA

7

NHRS1004IP

100A 30mA

10

CUSTOM BUILT To meet the ever changing requirements and designs of the modern electrical installation, Wylex offers a service where the standard range of products can be modified to specific customer needs. Our technical services and engineering teams can assess the feasability of a product requirement whilst our modern manufacturing facilities will produce a high quality competitive solution.

Insulated Range

NHISS5504


MAIN SWITCH

NH Metal Cased Range

6

CAT REF

MS RATING

MCB WAYS

+ DIN MODULES

NH206/40 NH206/63 NH506 NH806 NH1106 NH1406 NH1906

40A 63A 100A 100A 100A 100A 100A

2 2 5 8 11 14 19

NH506+3 NH806+3 NH806+6 NH1106+3

100A 100A 100A 100A

5 8 8 11

3 3 6 3

MCB WAYS

+ DIN MODULES

NH806

RCD INCOMER CAT REF

NHRS1106

RCD RATING

NHRS206/40 40A 30mA NHRS206/63 63A 30mA NHRS506 100A 30mA NHRS806 100A 30mA NHRS1106 100A 30mA NHRS1406 100A 30mA NHRS1906 100A 30mA NHRM206/40 40A 100mA NHRM206/63 63A 100mA NHRM506 100A 100mA NHRM806 100A 100mA NHRM1106 100A 100mA NHRM1406 100A 100mA NHRM1906 100A 100mA NHTM506 100A 100mA time delay NHTM806 100A 100mA time delay NHTM1106 100A 100mA time delay NHTM1406 100A 100mA time delay NHTM1906 100A 100mA time delay

2 2 5 8 11 14 19 2 2 5 8 11 14 19 5 8 11 14 19

NHRS506+3 NHRS806+3 NHRS806+6 NHRS1106+3

5 8 8 11

100A 30mA 100A 30mA 100A 30mA 100A 30mA

3 3 6 3

SPLIT LOAD CAT REF

NHRS4506

NHRS2406 NHRS3306 NHRS4206 NHRS5406 NHRS4506 NHRS3606 NHRS6306 NHRS3906 NHRS4806 NHRS6606 NHRS5706 NHRS7506 NHRS8406 NHRS9306 NHRS12506 NHRS11606 NHRS10706 NHRS61106 NHRS71006 NHRS9806 NHRS8906 NHRS51206

MS RATING

MCB WAYS

RCD RATING

MCB WAYS

100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

4 3 2 4 5 6 3 9 8 6 7 5 4 3 5 6 7 11 10 8 9 12

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

2 3 4 5 4 3 6 3 4 6 5 7 8 9 12 11 10 6 7 9 8 5

For Dual RCD insulated consumer units see page 8

NHRS6606

Flush mounting consumer units available to order. Suffix Catalogue Reference with /FLU eg: NHRS6606/FLU


DUAL TARIFF 100A MAIN SWITCH & 100A MAIN SWITCH CAT REF

MS RATING

MCB WAYS

MS RATING

MCB WAYS

100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

4 3 5 4 5 6 7 8 9 12 6

63A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A

2 3 4 5 7 6 5 9 8 5 11

DUAL TARIFF 100A MAIN SWITCH & 100A 30mA RCD SWITCH CAT REF

NHIIX4506

MS RATING

MCB WAYS

NHRSX5706 100A NHRSX6606 100A NHRSX7506 100A NHRSX8906 100A NHRSX9806 100A 100mA available to order

RCD RATING

7 6 5 9 8

MCB WAYS

100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA

5 5 7 8 9

SPLIT LOAD WITH TIME DELAY RCD INCOMER CAT REF

NHSTM6606

NHSTM3606 NHSTM4506 NHSTM5406 NHSTM6306 NHSTM3906 NHSTM4806 NHSTM5706 NHSTM6606 NHSTM7506 NHSTM8406 NHSTM9306 NHSTM12506 NHSTM11606 NHSTM8906 NHSTM9806 NHSTM10706 NHSTM71006 NHSTM61106 NHSTM51206

TD RCD RATING MCB WAYS

100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA

RCD RATING

MCB WAYS

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

3 4 5 6 3 4 5 6 7 8 9 12 11 8 9 10 7 6 5

6 5 4 3 9 8 7 6 5 4 3 5 6 9 8 7 10 11 12

FLEXIBLE SPLIT LOAD CONSUMER UNITS CAT REF

NHRS6SLM NHRS9SLM NHRS12SLM NHRS17SLM

MS RATING

100A 100A 100A 100A

MCB WAYS MIN MAX

2 3 3 5

4 6 9 12

RCD RATING

MCB WAYS MIN MAX

80A 30mA 80A 30mA 80A 30mA 80A 30mA

2 3 3 5

MCB WAYS TOTAL

4 6 9 12

6 9 12 17

NHRS12SLM FLEXIBLE SPLIT LOAD CONSUMER UNITS (TIME DELAY) CAT REF

TD RCD

NHSTM9SLM 100A 100mA NHSTM12SLM 100A 100mA NHSTM17SLM 100A 100mA

MCB WAYS MIN MAX

3 3 5

6 9 12

RCD RATING

MCB WAYS MIN MAX

80A 30mA 80A 30mA 80A 30mA

3 3 5

MCB WAYS TOTAL

6 9 12

9 12 17

SPLIT LOAD WITH DIN RAIL ACCESSORY SECTION CAT REF

NHRS5606+6 NHRS7706+3

MS RATING MCB WAYS RCD RATING MCB WAYS No of MODULE WAYS

100A 100A

100mA available to order

NH806+3

5 7

80A 30mA 80A 30mA

6 7

6 3

7 NH Metal Cased Range

NHIIX2406 NHIIX3306 NHIIX4506 NHIIX5406 NHIIX7506 NHIIX6606 NHIIX5706 NHIIX9806 NHIIX8906 NHIIX51206 NHIIX11606


METAL – SPLIT LOAD DUPLEX CAT REF

NHDIS88 NHDIS1111 NHDIS1414 NHDIS1919

8 NH Duplex Units & Skeleton Units

TOP BANK MS RATING MCB WAYS

NHDTMS88 NHDTMS1111 NHDTMS1414 NHDTMS1919

BOTTOM BANK RCD RATING MCB WAYS

100A 100A 100A 100A

8 11 14 19

80A 30mA 80A 30mA 80A 30mA 80A 30mA

8 11 14 19

100A 100mA TD 100A 100mA TD 100A 100mA TD 100A 100mA TD

8 11 14 19

80A 30mA 80A 30mA 80A 30mA 80A 30mA

8 11 14 19

METAL – DUAL TARIFF DUPLEX CAT REF

TOP BANK MS RATING MCB WAYS

BOTTOM BANK RCD RATING MCB WAYS

NHDIIX88 NHDIIX1111 NHDIIX1414 NHDIIX1919

100A 100A 100A 100A

8 11 14 19

100A 100A 100A 100A

8 11 14 19

NHDISX88 NHDISX1111 NHDISX1414 NHDISX1919

100A 100A 100A 100A

8 11 14 19

100A 30mA 100A 30mA 100A 30mA 100A 30mA

8 11 14 19

NHDSSX88 NHDSSX1111 NHDSSX1414 NHDSSX1919

100A 30mA 100A 30mA 100A 30mA 100A 30mA

8 11 14 19

100A 30mA 100A 30mA 100A 30mA 100A 30mA

8 11 14 19

NHDIS1414

METAL – DUAL SPLIT LOAD RCD CAT REF

NHISS3406 NHISS4606 NHISS5506 NHISS7806 NHISS8706

ISOLATOR TOTAL No of A B RATING MCB WAYS RCD RATING MCB WAYS MS RATING MCB WAYS

100A 100A 100A 100A 100A

7 10 10 15 15

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

4 6 5 8 7

80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA

3 4 5 7 8

NHISS5504

SKELETON UNITS CAT REF

DESCRIPTION

FALNH706 FALNH1106 FALNHRS706 FALNHRS1106 FALNH10SL* FALNH15SL* FALNHIIX10SL

7 way with main switch 11 way with main switch 7 way with main RCD 11 way with main RCD 10 way flexible split load 100A main switch 80A 30mA RCD 15 way flexible split load 100A main switch 80A 30mA RCD 10 way flexible dual tariff 2x 100A main switch

* Supplied with both metal and plastic covers

FALNH10SL


NSB MINIATURE CIRCUIT BREAKERS (6KA) CAT REF

RATING

POLES

MODULE

6A 10A 16A 20A 32A 40A 50A

1 1 1 1 1 1 1

1 1 1 1 1 1 1

NSB06 NSB10 NSB16 NSB20 NSB32 NSB40 NSB50

9

ACCESSORIES MCB Locking device Padlock for MCBLDX

NSC MODULAR CARTRIDGE FUSE HOLDERS WITH FUSE CAT REF

RATING

POLES

MODULE

SPARE FUSE

5A 10A 15A 20A 30A 35A 40A 45A

1 1 1 1 1 1 1 1

1 1 1 1 1 2 2 2

CFL05 CFL10 CFL15 CFL20 CFL30 CFL35 CFL40 CFL45

NSC05 NSC10 NSC15 NSC20 NSC30 NSC35 NSC40 NSC45

NSC05

NSC10

NSC20

NSC30

NSC45

NSBS COMBINED MCB/RCD UNITS

MTS12/1 MTS8/1

MESB-40NO

B CURVE

C CURVE

NSBS6-B/1* NSBS10-B/1* NSBS16-B/1* NSBS20-B/1* NSBS32-B/1* NSBS40-B/1* N/A N/A N/A N/A N/A N/A

CURRENT RATING

RCD RATING

POLES

MODULES

NSBS6/1* NSBS10/1* NSBS16/1* NSBS20/1* NSBS32/1* NSBS40/1*

6A 10A 16A 20A 32A 40A

30mA 30mA 30mA 30mA 30mA 30mA

SP SP SP SP SP SP

1 1 1 1 1 1

NSBS6/2 NSBS10/2 NSBS16/2 NSBS20/2 NSBS32/2 NSBS40/2

6A 10A 16A 20A 32A 40A

30mA 30mA 30mA 30mA 30mA 30mA

2P 2P 2P 2P 2P 2P

2 2 2 2 2 2

*NH Insulated units only

DIN RAIL MODULAR DEVICES FOR USE IN + UNITS & FLEXIBLE UNITS

MDT2

MAT1

CAT REF

PRODUCT

ME232-230 MDT2 MSTT-111 MSTT-227 MESB-20NO MESB-24NO MESB-40NO MESB-63NO MTS8 MTS6/1 MTS8/1 MTS12/1 MSTU6011S MSTU8011S MAT1

Staircase timer Digital time clock 1 channel 1xNO/NC contact 16A Digital time clock 1 channel 1xNO contact 16A Digital time clock 2 channel 20A 2 pole contactor 24A 4 pole contactor 40A 4 pole contactor 63A 4 pole contactor Bell transformer 12V 8VA Bell transformer 6V 8VA Bell transformer 8V 8VA Bell transformer 12V 8VA Disc type time clock 1 channel 1xNC contact 16A Disc type time clock 1 channel 1xNC contact 16A Disc type time clock 1 channel 1xNO contact 16A

MODULE

1 1 2 2 1 2 3 3 2 1 1 1 3 3 1

When wiring in NH Consumer Units contact Wylex technical services department

NH ACCESSORIES

NH00 NH00PP NHB1PP

CAT REF

PRODUCT

NHB1PP NH00PP NH00 DLDX NHET25

Blanking plate for busbar & cover Blanking plate twist fit for cover Blanking plate push fit for cover Isolator locking device 25mm Earth Terminal

NH Consumer Unit Outgoing Devices & Control Modules

NSB06 NSB10 NSB16 NSB20 NSB32 NSB40 NSB50

MCBLDX WPL



NH DISTRIBUTION BOARDS The Wylex range of NH distribution Boards is designed to cater for a variety of industrial and commercial applications. The range of boards is complemented by a wide variety of incoming options including direct connection, switch disconnector and RCD, outgoing devices include a broad selection of MCBs and RCBOs . This comprehensive collection of circuit protection and distribution products allows the contractor to select the most economical and electrically appropriate solutions. ● ●

All metal enclosures for both A Boards and B Boards

Two frame sizes 125A and 250A B Boards

Choice of incoming devices including Switch Disconnector, RCDs, or Direct Connection

B Boards accept four pole incomers (125A)

Over 250 different boards available from standard catalogue items

Removable pan assembly and gland plates for easy fixing and cable entry ●

Split neutral bars help make full use of interior space and keep all terminals accessible ●

Range of 10kA and 6kA MCBs ●

Single pole 18mm wide RCBOs


TYPE ‘A’ SP & N DISTRIBUTION BOARD

NH Distribution Boards

12

CAT REF

SWITCH RATING

NHSN51 NHSN81 NHSN111 NHSN141 NHSN161 NHSN191

125A 125A 125A 125A 125A 125A

NO. OF SP WAYS

5 8 11 14 16 19

A Boards excluding incomers available to order. Range of incoming devices shown opposite.

NHSN81

TP & N TYPE ‘B’ DISTRIBUTION BOARDS (Excluding Incomer) CAT REF

DESCRIPTION

NHTN4 NHTN6 NHTN8 NHTN12 NHTN16 NHTN20 NHTN24

125A Distribution board Excluding incomer 125A Distribution board Excluding incomer 125A Distribution board Excluding incomer 125A Distribution board Excluding incomer 125A Distribution board Excluding incomer 125A Distribution board Excluding incomer 125A Distribution board Excluding incomer

NO. OF TP WAYS

4 6 8 12 16 20 24

Suitable for use with switch disconnector, RCD or direct connection incomer arrangement IP66 TP & N MCB Distribution boards are available up to 16 TP ways

NHTN4

TP & N TYPE ‘B’ DISTRIBUTION BOARDS (Excluding Incomer) CAT REF

DESCRIPTION

NHTN2540 NHTN2560 NHTN2580 NHTN25120 NHTN25160 NHTN25200 NHTN25240

250A Distribution board Excluding incomer 250A Distribution board Excluding incomer 250A Distribution board Excluding incomer 250A Distribution board Excluding incomer 250A Distribution board Excluding incomer 250A Distribution board Excluding incomer 250A Distribution board Excluding incomer

NO. OF TP WAYS

NHTN25120 Suitable for switch disconnector, or direct connection incomer arrangement Flush mounting boards also available add suffix /FLU to Catalogue Reference eg: NHTN4/FLU

4 6 8 12 16 20 24


NH A BOARD INCOMERS DESCRIPTION

RATING

WS602 WS102 WS122 WRS63/2 WRS80/2 WRS100/2 WRM63/2 WRM80/2 WRM100/2 WRL63/2 WRL100/2 WRMT100/2 NHDPDC

2 Pole 2 module switch 2 Pole 2 module switch 2 Pole 2 module switch Double Pole RCD Double Pole RCD Double Pole RCD Double Pole RCD Double Pole RCD Double Pole RCD Double Pole RCD Double Pole RCD Double Pole Time Delay RCD Double Pole direct connection

63A 100A 125A 63A 30mA 80A 30mA 100A 30mA 63A 100mA 80A 100mA 100A 100mA 63A 300mA 100A 300mA 100A 100mA 100A

NH B BOARD INCOMERS

WS123

CAT REF

DESCRIPTION

RATING

WS603 WS103 WS123 WS604 WS104 WS124 WRS63/4 WRS100/4 WRM63/4 WRM100/4 WRL63/4 WRL100/4 WRMT100/4 NH4PINKIT NH200TPSW NH250TPSW NHTPDC NH250DC NHSPAK

3 Pole 3 module switch 3 Pole 3 module switch 3 Pole 3 module switch 4 Pole 4 module switch* 4 Pole 4 module switch* 4 Pole 4 module switch* Four Pole RCD* Four Pole RCD* Four Pole RCD* Four Pole RCD* Four Pole RCD* Four Pole RCD* Four Pole Time Delay RCD* Four Pole Incomer Connection Kit* Three Pole switch disconnector Three Pole switch disconnector Direct connection Direct connection Single phase adaptor kit

63A 100A 125A 63A 100A 125A 63A 30mA 100A 30mA 63A 100mA 100A 100mA 63A 300mA 100A 300mA 100A 100mA 100A 200A 250A 125A 250A 125A

* Four Pole DIN Incomers require Incomer connection Kit. REF, NH4PINKIT

EXTENSION & ACCESSORY BOXES

NHAB2

CAT REF

DESCRIPTION

DIN MODULES

NHEB NHEB/DIN NHAB NHAB2 NHAB3 NHAB4 NHAB5

Cable extension box (plain) DIN accessory box single row (plain) DIN accessory box single row DIN accessory box two row DIN accessory box three row DIN accessory box four row DIN accessory box five row

18 36 54 72 90

18 modules per row

ACCESSORIES

NH4PINKIT

CAT REF

DESCRIPTION

NHEP11 NH00 NHB1PP 3TPBP PSBL1 PSBL3 MCBLDX WPL NHPBDL PDDPL WDH-1 NHCEKIT NHCEKIT20 NHMSL

Replacement gland plate Way blank 1 Way busbar & cover blank 9 way busbar & MCB way blank kit Way blank (single module) Way blank (3 module) Locking device for MCB Padlock for MCBLDX MCB Board door lock Doorlock with padlocking device Document wallet 14 terminal clean earth kit 20 terminal clean earth kit Locking device DIN Main Switch

13 NH Distribution Board Incoming Units & Accessories

WS102

CAT REF


SINGLE POLE MCBs RATING

NH Miniature Circuit Breakers

14

PSB06-B

PSB32-B

PSB63-B

6A 6kA 10A 6kA 16A 6kA 20A 6kA 32A 6kA 40A 6kA 50A 6kA 63A 6kA 6A 10kA 10A 10kA 16A 10kA 20A 10kA 32A 10kA 40A 10kA 50A 10kA 63A 10kA

POLES

B CURVE

C CURVE

D CURVE

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

NSB06-B NSB10-B NSB16-B NSB20-B NSB32-B NSB40-B NSB50-B NSB63-B PSB06-B PSB10-B PSB16-B PSB20-B PSB32-B PSB40-B PSB50-B PSB63-B

NSB06-C NSB10-C NSB16-C NSB20-C NSB32-C NSB40-C NSB50-C NSB63-C PSB06-C PSB10-C PSB16-C PSB20-C PSB32-C PSB40-C PSB50-C PSB63-C

NSB06-D NSB10-D NSB16-D NSB20-D NSB32-D NSB40-D NSB50-D NSB63-D PSB06-D PSB10-D PSB16-D PSB20-D PSB32-D PSB40-D PSB50-D PSB63-D

TWO POLE MCBs RATING

6A 10A 16A 20A 32A 40A 50A 63A

PSB206-B

10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA

POLES

B CURVE

C CURVE

D CURVE

2 2 2 2 2 2 2 2

PSB206-B PSB210-B PSB216-B PSB220-B PSB232-B PSB240-B PSB250-B PSB263-B

PSB206-C PSB210-C PSB216-C PSB220-C PSB232-C PSB240-C PSB250-C PSB263-C

PSB206-D PSB210-D PSB216-D PSB220-D PSB232-D PSB240-D PSB250-D PSB263-D

PSB232-B

TRIPLE POLE MCBs RATING

PSB306-B

PSB332-B

6A 10A 16A 20A 32A 40A 50A 63A 6A 10A 16A 20A 32A 40A 50A 63A

6kA 6kA 6kA 6kA 6kA 6kA 6kA 6kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA

POLES

B CURVE

C CURVE

D CURVE

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

NSB306-B NSB310-B NSB316-B NSB320-B NSB332-B NSB340-B NSB350-B NSB363-B PSB306-B PSB310-B PSB316-B PSB320-B PSB332-B PSB340-B PSB350-B PSB363-B

NSB306-C NSB310-C NSB316-C NSB320-C NSB332-C NSB340-C NSB350-C NSB363-C PSB306-C PSB310-C PSB316-C PSB320-C PSB332-C PSB340-C PSB350-C PSB363-C

NSB306-D NSB310-D NSB316-D NSB320-D NSB332-D NSB340-D NSB350-D NSB363-D PSB306-D PSB310-D PSB316-D PSB320-D PSB332-D PSB340-D PSB350-D PSB363-D

For other ratings please contact Wylex technical


SINGLE MODULE RCBO - FOR USE IN NH DISTRIBUTION BOARDS RATING

6A 10A 16A 20A 32A 40A 50A

POLES

10kA 10kA 10kA 10kA 10kA 10kA 10kA

C CURVE

1 1 1 1 1 1 1

30mA 30mA 30mA 30mA 30mA 30mA 30mA

PSBS6/1 PSBS10/1 PSBS16/1 PSBS20/1 PSBS32/1 PSBS40/1 PSBS50/1

15

ACCESSORIES

MCBLDX WPL

NH00 NH00PP

CAT REF

DESCRIPTION

MCBLDX WPL PS00 PSBL3 3TPBP NH00 NH00PP NHB1PP

Locking device for MCB/RCBO Padlock for MCBLDX Way Blank - (2x Half Module) Way Blank - 3 Module Blank kit 9 modules & 9 MCB way blank Way Blank - 1 Module Twist Fit 1 module blank Busbar & cover blank 1 module

NHB1PP

TWO MODULE RCBO - NOT FOR USE IN NH DISTRIBUTION BOARDS RATING

6A 10A 16A 20A 32A 40A 6A 10A 16A 20A 32A 40A

PSBS40/2

POLES

6kA 6kA 6kA 6kA 6kA 6kA 10kA 10kA 10kA 10kA 10kA 10kA

C CURVE

2 2 2 2 2 2 2 2 2 2 2 2

30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA 30mA

NSBS6/2 NSBS10/2 NSBS16/2 NSBS20/2 NSBS32/2 NSBS40/2 PSBS6/2 PSBS10/2 PSBS16/2 PSBS20/2 PSBS32/2 PSBS40/2

For use in DIN Enclosures EG: NH ED Range or + Units

DIN RAIL MODULAR DEVICES

MESB-40NO

CAT REF

PRODUCT

MDT2 MSTT-111 MSTT-227 MESB-20NC MESB-20NO MESB-24NC MESB-24NO MESB-40NC MESB-40NO MESB-63NC MESB-63NO

Digital Timeclock 1 channel 1xNO/NC Contact 16A Digital Timeclock 1 channel 1xNO Contact 16A Digital Timeclock 2 channel 240V Coil 2 Pole 20A Contact rating 2 x N/C 240V Coil 2 Pole 20A Contact rating 2 x N/O 240V Coil 4 Pole 24A Contact rating 4 x N/C 240V Coil 4 Pole 24A Contact rating 4 x N/O 240V Coil 4 Pole 40A Contact rating 4 x N/C 240V Coil 4 Pole 40A Contact rating 4 x N/O 240V Coil 4 Pole 63A Contact rating 4 x N/C 240V Coil 4 Pole 63A Contact rating 4 x N/O

For use in DIN Enclosures EG: NH ED Range or + Units

MODULE

1 1 2 1 1 2 2 3 3 3 3

SP & SPSN RCBOs & Modular Devices

PSBS32/1


NH125 MCCB PANEL BOARDS NH MCCB Panel Boards offer 250A or 400A fault rated, fully shrouded busbar systems in a modular enclosure system. The 630mm wide enclosure system combined with MCCBs and a range of accessories, provides a competent flexible main or sub-main distribution board.

MCCBs with 25kA fault breaking capacity

25A - 125A ratings

70mm2 cable clamp terminals or 10mm flat bar

Full Range of accessories including sealable terminal covers

Fully shrouded bus bars

Excellent access to N/E bars for cabling

Full or partial lockable doors

Fully conforms with BSEN 60943-1 form 2


250A SWITCH DISCONNECTOR INCOMER

250A

OUTGOING MODULAR WAYS HEIGHT

HEIGHT (mm)

CAT REF

6 8 12

902 902 1060

NHPB6SW250 NHPB8SW250 NHPB12SW250

17 17 20

NHPB6SW250

200A MCCB INCOMER

200A

OUTGOING MODULAR WAYS HEIGHT

HEIGHT (mm)

CAT REF

6 8 12

902 902 1060

NHPB6CB200 NHPB8CB200 NHPB12CB200

17 17 20

BSEN 60439 250A Busbars ● Busbar fault rated 25kA–1 sec ● IP31 (41 with door) Ingress Protection ● Earth and neutral terminals for each SP way ● 630mm wide x 165mm deep ● 120 mm2 4 Core Max on Incoming Terminals ● 70 mm2 4 Core Max on Outgoing Terminals ● Fully assembled ● Complete with incomer ●

NHPB6CB200

DOOR KITS PANELBOARD

6/8 way 12 way Door lock

MODULAR HEIGHT

CAT REF

17 20

NHFHDK17 NHFHDK20 NHPBDL

ACCESSORY BOXES PANELBOARD

MODULAR HEIGHT

HEIGHT (mm)

Cable Spreader Box DIN Accessory Box A Board 13 way

4

210

CAT REF

NHCSB NHGAB NHG13DB

NHFDK17 All NH Panelboard enclosures are 630mm wide x 165mm deep x modular height 1 Module = 52.5mm. Colour finish RAL 7035

17 NH125 Panel Boards

BSEN 60439 250A Busbars ● Busbar fault rated 25kA–1 sec ● IP31 (41 with door) Ingress Protection ● Earth and neutral terminals for each SP way ● 630mm wide x 165mm deep ● 120 mm2 4 Core Max on Incoming Terminals ● 70 mm2 4 Core Max on Outgoing Terminals ● Fully assembled ● Complete with incomer ● Also available excluding incomer for direct connection applications ●


400A SWITCH DISCONNECTOR INCOMER

400A

18

OUTGOING WAYS

MODULAR HEIGHT

HEIGHT (mm)

6 8 12 16

20 20 23 26

1060 1060 1217 1375

CAT REF

NHPB6SW400 NHPB8SW400 NHPB12SW400 NHPB16SW400

BSEN 60439 400A Busbars ● Busbar fault rated 25kA–1 sec ● IP31 (41 with door) Ingress Protection ● Earth and neutral terminals for each SP way ● 630mm wide x 165mm deep ● 240 mm2 4 Core Max on Incoming Terminals ● 70 mm2 4 Core Max on Outgoing Terminals ● Fully assembled ● Complete with incomer ● Also available excluding incomer for direct connection applications

NH125 Panel Boards

NHPB6SW400

400A MCCB INCOMER

400A

OUTGOING WAYS

MODULAR HEIGHT

HEIGHT (mm)

6 8 12 16

20 20 23 26

1060 1060 1217 1375

CAT REF

NHPB6CB400 NHPB8CB400 NHPB12CB400 NHPB16CB400

Conforms to BSEN 60439 400A Busbars ● Busbar fault rated 25kA–1 sec ● IP31 (41 with door) Ingress Protection ● Earth and neutral terminals for each SP way ● 630mm wide x 165mm deep ● 240 mm2 4 Core Max on Incoming Terminals ● 70 mm2 4 Core Max on Outgoing Terminals ● Fully assembled ● Complete with incomer ●

NHPB6CB400

DOOR KITS PANELBOARD

MODULAR HEIGHT

6/8 way

20

12 way

23

16 way

26

CAT REF

NHFHDK20 NHCBDK12 NHCBDK11 NHCBDK15 NHCBDK11 NHPBDL

Door lock

EXTENSION BOXES PANELBOARD

Cable Spreader Box DIN Accessory Box A Board 13 way

NHFHDK20

MODULAR HEIGHT

HEIGHT (mm)

4

210

CAT REF

NHCSB NHGAB NHG13DB

} }


NH SINGLE POLE MCCBS ●

Conforms to BSEN 60947-2 16kA Icu at 240V ac ● Fixed magnetic ● Fixed thermal ● Double insulated ● Terminal Capacity 70mm2 ●

RATING

NHGPCB251 NHGPCB321 NHGPCB401 NHGPCB501 NHGPCB631 NHGPCB801 NHGPCB1001 NHGPCB1251

NHGPCB1001

NH THREE POLE MCCBS ●

Conforms to BSEN 60947-2 25kA Icu at 415V ac ● Fixed magnetic ● Fixed thermal ● Double insulated ● Large range of accessories ● Terminal Capacity 70mm2 ●

RATING

25A 32A 40A 50A 63A 80A 100A 125A

CAT REF

NHGPCB253 NHGPCB323 NHGPCB403 NHGPCB503 NHGPCB633 NHGPCB803 NHGPCB1003 NHGPCB1253

NHGPCB633

NH MCCBs ACCESSORIES DESCRIPTION

CAT REF

70mm Terminal adaptor (2x25 to 1x70mm) Dolly and padlocking facility Padlock to fit

NHPBN25/70 NHPCBLDX NHPCBPL

1P Terminal Shroud 3P Terminal Shroud

NHPCB1TS NHPCB3TS

AUXILIARY EQUIPMENT

Auxiliary Contacts 1 x n.o./n.c. Volt Free 2 x n.o./n.c. Volt Free MCB Blanking kit 3x TP Ways

NHCB1TS

NHCB3TS

NHPCBAU1 NHPCBAU2 3TPBP

19 NH125 Panel Board Circuit Breakers

25A 32A 40A 50A 63A 80A 100A 125A

CAT REF


NH FUSE-COMBINATION UNITS NH Fuse combination units are designed with features that ensure full compliance with EN60947 while also providing an economical and high quality range of industrial switchgear products. With ratings from 20A to 200A and a choice of single pole or three pole configurations, NH fuse combination units have a utilisation category of AC23A, and fused short circuit capacity of 80kA.

Robust steel enclosures with cable glanding plate supplied top and bottom

Removable door opens through 180º for ease of access

Easy access fuse link fixings

Fully rated neutral

Fully shrouded terminals

Handle padlocking facility locks switch & door in off position

Large cable terminal capacity

Ingress protection to IP4X

Positive indication of On and Off


NH FUSE COMBINATION UNIT 20A-32A 20A

SP&N TP&N

supplied with 20A fuses

NHSPSF20 NHTPSF20

32A

SP&N TP&N

supplied with 32A fuses

NHSPSF32 NHTPSF32

21

NH FUSE COMBINATION UNIT 63A-125A 63A

SP&N TP&N

supplied with 63A fuses

NHSPSF63 NHTPSF63

100A

SP&N TP&N

supplied with 100A fuses

NHSPSF100 NHTPSF100

125A

TP&N

supplied with 125A fuses

NHTPSF125

Accessories 63A 100A & 125A 63A 100A & 125A

Copper Isolator Link Copper Isolator Link Cable Spreader Box

NHCIL2 NHCIL3 NHCSB2

NHTPSF63

NH FUSE COMBINATION UNIT 160A-400A

NHTPSF160

160A

TP&N

no fuses supplied

NHTPSF160

200A

TP&N

no fuses supplied

NHTPSF200

315A

TP&N

no fuses supplied

NHTPSF315

400A

TP&N

no fuses supplied

NHTPSF400

Accessories 160A & 200A 160A & 200A 315A & 400A 315A & 400A

Copper Isolator Links Cable Spreader Box Copper Isolator Links Cable Spreader Box

Fuse Combination Units Technical Specification EN 60947-3 80kA RMS Fused Short Circuit Capacity 415V ac Rated Voltage

NHCIL3 NHCSB3 NHCIL4 NHCSB4 IEC 947-3 AC23A Utilisation Category Full Uninterrupted Duty

NH ISOLATOR SWITCHES STEEL ENCLOSURE RATING

20A 32A 40A 63A 63A 100A 125A

BOX SIZE

1 1 1 1 2 2 2

TP&N/SP&N

NHSW320 NHSW332 NHSW340 NHSW363 NHSW363X NHSW3100 NHSW3125

NHSW63X Spreading Room is allowed for at one end only. To fit a 4 core cable at both ends an additional Cable spreader box will be required. Above 22mm wide cable lugs terminal interphase barriers are required. 1 Module=52.5mm. Contact Wylex Technical Services department for details.

NH Fuse Combination Units & Isolator Switches

NHSPSF32



STANDARD RANGE The Wylex Standard range of consumer units remains one of the most widely used ranges in domestic circuit protection applications.

This time saving feature offers installers an economical alternative to full consumer unit replacement.

Originally designed with fuses in mind, standard consumer units can easily be upgraded to current standards by using the plug in range of MCBs.

The range also includes SP&N switch fuses up to 100A allowing for submain circuit installation or system extensions / additions to be easily completed.


INSULATED - SWITCH FUSE CAT REF

CURRENT RATING

NO. OF WAYS

45A 60A 60A

1 1 1

104 108 160C

‘C’ models supplied with cartridge fuse

Standard Range

24

104

INSULATED-MAIN SWITCH ISOLATOR CAT REF

ISOLATOR RATING

NO. OF WAYS

45A 60A 60A 100A 100A

2 3 4 6 8

CAT REF

CURRENT RATING

NO. OF WAYS

106 106 RED 108M 160CM* 110M/63* 110M/80* 110M*

45A 45A 60A 60A 63A 80A 100A

1 1 1 1 1 1 1

204 304 404 604 804

204

METAL- SWITCH FUSE

*Supplied complete with cartridge fuse

160CM

110M

METAL-MAIN SWITCH ISOLATOR CAT REF

206 306 406 606

106

206

ISOLATOR RATING

NO. OF WAYS

45A 45A 60A 100A

2 3 4 6


MCBs CAT REF

B6 B10 B16 B20 B32 B40

B10

B16

B20

B32

CONTACT SHIELD COLOUR

6A 10A 16A 20A 32A 40A

WHITE GREY BLUE YELLOW RED ORANGE

B40

CARTRIDGE FUSES (Including contact shield +Carrier) CAT REF

C5 C15 C20 C30 C35 C40 C45 CAT REF

L45 L60

C5

C15

C20

C30

C35

C40

C45

CURRENT RATING

CONTACT SHIELD COLOUR

5A 15A 20A 30A 35A 40A 45A

WHITE BLUE YELLOW RED ORANGE ORANGE GREEN

CURRENT RATING

45A 60A

}

for use with 108, 145 & 160 type switch fuses

CARTRIDGE FUSE LINKS (FUSE ONLY) CAT REF

CFL5 CFL10 CFL15 CFL20 CFL30 CFL35 CFL40 CFL45

CURRENT RATING

CONTACT SHIELD COLOUR

5A 10A 15A 20A 30A 35A 40A 45A

WHITE BLUE BLUE YELLOW RED ORANGE ORANGE GREEN

CURRENT RATING

CONTACT SHIELD COLOUR

5A 15A 20A 30A

WHITE BLUE YELLOW RED

REWIRABLE FUSES CAT REF

R5 R15 R20 R30

CARTRIDGE FUSE LINKS (FUSE ONLY) CAT REF

R5

R15

R20

R30

LFL45 LFL60 LFL63 LFL80 LFL100

CURRENT RATING

}

45A for use with 108 or 108M 60A 63A for use with 110M 80A units only 100A

}

ACCESSORIES

M10

CAT REF

DESCRIPTION

FWC M10

Fusewire card 1m 5A, 15A, 30A Blank shield for unused ways

25 Standard Range Outgoing Devices & Accessories

B6

CURRENT RATING



LIFELINE RANGE The Lifeline range of residual current devices, rcd’s provides valuable additional protection to almost any type of installation by detecting earth fault current below the level sensed by traditional overcurrent devices such as fuses of miniature circuit breakers.

One of the largest ranges available in the UK today offers other features which include:●

Fully shrouded terminals

Contact position indication on the dolly handle

Both Type AC and Type A (DC sensitive) devices available

A range of enclosures from IP20 upto IP65

Time delay versions available in 2 and 4 pole configurations


2 POLE RCDs – TYPE AC CAT REF

WRS16/2 WRS25/2 WRS32/2 WRS40/2 WRM40/2 WRS63/2 WRM63/2 WRL63/2 WRS80/2 WRM80/2 WRS100/2 WRM100/2 WRL100/2

Lifeline Range

28

WRS32/2

RATED CURRENT

SENSITIVITY

16A 25A 32A 40A 40A 63A 63A 63A 80A 80A 100A 100A 100A

30mA 30mA 30mA 30mA 100mA 30mA 100mA 300mA 30mA 100mA 30mA 100mA 300mA

WRS80/2

2 POLE RCDs DC SENSITIVE – TYPE A CAT REF

WRDVS32/2 WRDS40/2 WRDM40/2 WRDS63/2 WRDS80/2 WRDS100/2 WRDM100/2

WRS100/2

RATED CURRENT

SENSITIVITY

32A 40A 40A 63A 80A 100A 100A

10mA 30mA 100mA 30mA 30mA 30mA 100mA

WRM100/2

4 POLE RCDs – TYPE AC CAT REF

WRS32/4 WRS40/4 WRM40/4 WRS63/4 WRM63/4 WRL63/4 WRS100/4 WRM100/4 WRL100/4

RATED CURRENT

SENSITIVITY

32A 40A 40A 63A 63A 63A 100A 100A 100A

30mA 30mA 100mA 30mA 100mA 300mA 30mA 100mA 300mA

4 POLE RCDs DC SENSITIVE – TYPE A CAT REF

WRS63/4

WRDS40/4 WRDM40/4 WRDS63/4 WRDM63/4 WRDS100/4 WRDM100/4

RATED CURRENT

SENSITIVITY

40A 40A 63A 63A 100A 100A

30mA 100mA 30mA 100mA 30mA 100mA

TIME DELAY UNITS (100ms) CAT REF

WRMT100/2 WRMT100/4

WRMT100/4

DESCRIPTION

RATED CURRENT

SENSITIVITY

2P 4P

100A 100A

100mA 100mA


DIN ENCLOSURES IP RATING

CAT REF INSULATED

CAT REF METAL

2 2 2

IP40 IP40 IP54

ESE2 ESE2L* -

ESM6 ESM7

4 4 4 4

IP20 IP40 IP54 IP54

ESE4 ESi4 -

ESM8 ESM11 ESM13**

* Supplied with earth connection link ** Larger enclosure for larger cables

ESE2

ESE4

IP65 DIN ENCLOSURES AND ACCESSORIES WBE4/NK installed in WBE4

CAT REF

DESCRIPTION

WBE3 WBE4 WBE3/EK WBE3/NK WBE4/EK WBE4/NK WBE/BS WME/FB

2/3 module enclosure 4 module enclosure Earth block Neutral block Earth block Neutral block Blanks Wall mounting plate

NH INSULATED DIN ENCLOSURES CAT REF

DESCRIPTION

NH4ED4 4 modules NH7ED4 7 modules NH10ED4 10 modules NH13ED4 13 modules NH16ED4 16 modules NH21ED4 21 modules Supplied with earth & neutral terminal bars cover and visor

NH10ED4

NH METAL DIN ENCLOSURES CAT REF

DESCRIPTION

NH4ED6 4 modules NH7ED6 7 modules NH10ED6 10 modules NH13ED6 13 modules NH16ED6 16 modules NH21ED6 21 modules Supplied with earth & neutral terminal bars cover and visor

NH13ED6

29 Enclosures Range

DIN MODULES


SWITCH DISCONNECTORS & ISOLATORS Wylex provide a range of isolators designed for applications where local isolation is required. The modular WS range of switches can be independently configured to provide a variety of live and neutral arrangements up to 4 poles. In addition Wylex offer a range of enclosed switch disconnector isolators suitable for commercial and industrial applications up to 125A. Rotary isolators can be locked in the off position and have facility for up to 3 padlocking devices for added safety and security.


TRIPLE POLE & NEUTRAL 415V, 50HZ AC CAT REF

DESCRIPTION

921E

With switched neutral, surface mounting in a metal enclosure With switched neutral, for loose mounting in an enclosure (Non DIN)

921X

CURRENT RATING

32A 32A

31

NH ISOLATOR SWITCHES STEEL ENCLOSURE RATING

20A 32A 40A 63A 63A 100A 125A

BOX SIZE

1 1 1 1 2 2 2

TP&N/SP&N

NHSW320 NHSW332 NHSW340 NHSW363 NHSW363X NHSW3100 NHSW3125

NHSW363X

SUPPLY AUTHORITY ISOLATOR ASSEMBLIES CAT REF

DESCRIPTION

REC2S REC2 REC3 REC4

Slimline & DP Switch Enclosure DP Isolator & 4 Mod Enclosure TP Isolator & 4 Mod Enclosure 4P Isolator & 4 Mod Enclosure

CURRENT RATING

100A 100A 100A 100A

A wide range of custom built variations is also available. Contact Wylex Technical for full details.

REC2S

REC4

WS RANGE OF MODULAR ISOLATORS

WS102

WS104

CAT REF

DESCRIPTION

WS601 WS101 WS121

1 Pole, 1 module 1 Pole, 1 module 1 Pole, 1 module

CURRENT RATING

63A 100A 125A

WS602 WS102 WS122

2 Pole, 2 module 2 Pole, 2 module 2 Pole, 2 module

63A 100A 125A

WS603 WS103 WS123

3 Pole, 3 module 3 Pole, 3 module 3 Pole, 3 module

63A 100A 125A

WS604 WS104 WS124

4 Pole, 4 module 4 Pole, 4 module 4 Pole, 4 module

63A 100A 125A

Isolators & Switch Disconnectors

921E


TECHNICAL DATA & DIMENSIONS

D

A

C E

B Fault

Maximum prospective fault current

A

Healthy circuit current

20ms

20ms

B


MCB INTERNAL VIEW

Box terminal

33

Fixed contact

Trip bar Arc runner

Moving contact

Thermo-element

Box terminal Busbar aperture DIN clip

GENERAL CONSTRUCTION Wylex MCBs are of the thermal-magnetic current limiting type, having a compact construction which has been achieved by not only minimising the number of parts but also the number of welded joints and connections. Critical material selection ensures reliability and durability. Typical of this is the choice of silver graphite for the fixed contact. The MCB has an easy to operate handle with a trip-free toggle mechanism – so even when the handle is held in the ‘on’ position the MCB is free to trip. AMBIENT TEMPERATURE CONSIDERATIONS Wylex MCBs are calibrated to meet the requirements of BS EN 60898, 30°C Ref Calibration Temperature. At other temperatures the following rating factors should be used: At 60°C 0.9

At 20°C 1.0

At 0°C 1.1

Adjacent thermal-magnetic MCBs should not be continuously loaded at or approaching their nominal rated currents when mounted in enclosures. It is good engineering practice to apply generous derating factors or make provision for adequate free air between devices. In these situations, and in common with other manufacturers, we recommend a 66% diversity factor is applied to the MCB nominal rated current where it is intended to load the MCBs continuously (in excess of 1 hour). METHOD OF OPERATION 1 Moderate overload conditions Detection of moderate overload conditions is achieved by the use of a thermo-metal element which deflects in response to the current passing through it. The thermo-metal element moves against the trip bar releasing the trip mechanism.

2 Short circuit conditions When the current flowing through the MCB reaches a predetermined level, the solenoid directly pulls in the plunger which forcibly separates the contacts and simultaneously releases the trip mechanism. 3 Establishment of arc between fixed and moving contacts As the moving contact moves away from the fixed contact, an arc is established. The arc runs along the arc runner to the arc chamber where it is split up between the plates and extinguished. The low inertia and consequent high speed of the moving contact has a limiting effect on the flow of fault current. The rapid development of the arc, together with its accelerated extinction in the arc chamber, gives a typical operating time of 3.5–5 milliseconds. CURRENT LIMITING ACTION The high speed current limiting action ensures that the MCB operates before the full prospective fault current is allowed to develop. Under fault conditions, damage can be sustained to the installation and associated equipment due to the amount of energy that passes before the current is completely interrupted. The total energy let-through depends on the value of current and the time for which it flows, and is denoted by the symbol I2t. The high speed current limiting action of MCBs ensures that the energy let-through and any subsequent damage is minimised. This reduced energy let-through assists greatly with both back-up and discrimination considerations. CURRENT LIMITING EFFECT Fault

Maximum prospective fault current

Healthy circuit current

20ms

20ms

MCBs - Technical Data

Hammer action solenoid Arc chamber


BACK-UP PROTECTION

NSB CONSUMER UNIT MCBs

Back-up protection is required only if the prospective short circuit current at the point of installation exceeds the breaking capacity of the MCB. When providing back-up protection consideration must be given to discrimination between the MCB and fuse.

British standards Rated voltage (single pole) Tripping characteristics Short circuit rating Reference calibration temperature Terminal capacity – outgoing cable

DISCRIMINATION It is desirable that the protective device nearest the fault should operate first. The low energy let through of modern MCBs provides better discrimination with HRC fuse back-up than is given by earlier types of MCBs. 1.13 1.45 120 60 40

CAT REF

RATING

NSB06 NSB10 NSB16 NSB20 NSB32 NSB40 NSB50

6A 10A 16A 20A 32A 40A 50A

20

20 10

sec

6

.01

1 40

4 3

125 A

2

1

100 A 80 A

6A

63 A

104

6 4

40 A 32 A 25 A 20 A 16 A 10 A

BS88 FUSE 160A

=0

2

In=

105 8

HW

6 4

Let-through I2t (amp2/sec)

Minutes

Tripping time

10

Seconds

8

50 A

6

2

40 A

2

4

1

3

0.6 0.4

35 A

2

ac

32 A

0.2 0.1

103 4x102

0.06 0.04 0.02 0.01

6

8 103

2

3

4

6

8 104

Prospective short circuit current Ip/A

1

1.5 2

3 3

4 5 6 8 10 5 7

15 20

1

min melting pt (pre-arching) eg In=125A BS 88

2

max let-through I2t of MCB eg 6A

30

Multiple of rated current

NSB AND PSB DISTRIBUTION BOARD MCBs British Standards

BSEN 60898 - 1991

Rated Voltage

230/400 Volts

Tripping characteristics

Type B, C and D

Short circuit rating Reference calibration temperature Terminal capacity outgoing cable

6kA and 10kA

1 HR

1,000

30˚C 0.75 to 25mm2

NSBS & PSBS RCBO (COMBINED MCB/RCD) British Standards

BSEN 61009

Rated Voltage

230 Volts

SP or SP with switched neutral Tripping characteristics Type C Short circuit rating Reference calibration temperature Rated residual operating current Single module Two module Terminal capacity outgoing cable

2 HRS

6kA and 10kA

100

OPERATING TIME IN SECONDS

MCB & RCBO – Technical Data

34

BS EN 60898: 1991 240V Type B 6kA 30°C 0.75 to 25mm2

10

1.0

30˚C 30mA Type A Type AC 0.5 to 16mm2

Unique live side busbar combi-terminal allows connection of cable up to 25mm2 Maximum neutral cable size 25mm2

0.1

Type B

Type C

Type D

0.01 0.001 1

3

5

10

20

100

SHORT CIRCUIT CURRENT AS A MULTIPLE OF RATED CURRENT

1,000


APPLICATION GUIDE FOR RESIDUAL CURRENT DEVICES A test button is provided on all RCDs to enable the operation of the device to be checked. It is recommended that an RCD is tested regularly. (See BS 7671 Regulation 514-12-02). Scope of Protection

Application Method

Type

35

RCCB controlled consumer unit

RCCB

Split load consumer unit

RCCB

Consumer unit with RCBO controlling individual circuit SP or DP option available

RCBO

OPERATION The RCD employs the current balance principle which involves the supply conductors to the load (phase and neutral) being wound onto a common transformer core to form the primary windings. Under healthy circuit conditions, the current in the phase conductor is equal to the current in the neutral, and the vector sum of the current is zero. In the event of an earth fault, an amount of current will flow to earth, creating an out of balance situation in the transformer assembly. This out of balance is detected by the secondary winding of the transformer and at a pre-determined level of out of balance will activate the trip mechanism. Single phase and neutral or three phase and neutral units (suitable for 3 or 4 wire systems) are available, the latter being suitable for balanced or unbalanced 3 phase loads. The RCD trip mechanism will operate at a residual current of between 50–100% of its rating tripping current (sensitivity).

Selected Circuits

Individual Circuits

TRANSIENT EARTH LEAKAGE CURRENTS All Wylex residual current devices incorporate a high level of immunity to tripping when subjected to transient earth leakage currents. Such transients can occur when there is a significant level of capacitance to earth as can result from cable capacitance (particularly MICC) or RF filter networks. Wylex RCDs are therefore less susceptible to nuisance tripping due to transient earth leakage currents.

Individual Socket Outlets Combined RCD / socket outlet

SRCD

Combined RCD / adaptor

PRCD

RESIDUAL TRIPPING CURRENTS 10mA Used in special applications where additional protection against contact is essential due to the nature of the installation. 30mA Tripping current designated by the IEE Wiring Regulations to provide additional protection against direct contact shock, ie socket outside the equipotential zone. TT systems, caravan installation, etc. 100mA Suitable for use against indirect contact shock or where protection is provided to guard against firehazard, etc, rather than to provide additional protection to personnel, and where the earthing requirements need supplementing by RCD protection. 100mA time delay Suitable for use when total RCD protection is required to supplement the system earthing and where local 30mA RCDs are used to give additional protection against direct contact. The time delay RCD will discriminate with the 30mA RCD. 300mA For use in large installations where plant and equipment protection are the main considerations and high levels of earth leakage are experienced.

Individual Appliances

Lifeline Range: RCDs – Technical Data

All Circuits


IEC PUBLICATION (479) CURVES WITH WYLEX RCD CHARACTERISTICS SUPERIMPOSED TIME/CURRENT ZONES OF EFFECT OF AC CURRENT (15–100Hz) ON PERSONS a

10,000

c1 c2

c3

IEC 479

5,000

36

2000 1000 Time in milliseconds

Lifeline Range RCDs – Technical Data

b

500 1

2

3

4

200 100 50

20 10 0.1

0.2 0.3 0.5

1

2

3

5

10

20

Current in milliamperes (RMS) 30mA

30

50

100

200 300 500

1,000 2,000 3,000 5,000 10,000

Typical current Limits due to body resistance at 230V

100mA

Zone Physiological effects 1

Usually no reaction effects.

2

Usually no harmful physiological effects.

3

Usually no organic damage to be expected. Likelihood of muscular contraction and difficulty of breathing, reversible disturbances of formation and conduction of impulses in the heart, and transient cardiac arrest without ventricular fibrillation increases with current magnitude and time.

4

In addition to the effects of zone 3, probability of ventricular fibrillation increased up to 5% (Curve C2), up to 50% (Curve C3) and above 50% beyond Curve C3. Increasing with magnitude and time, pathyphysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur.

FAULT CURRENT SENSITIVITY Semi-conductor devices are now incorporated in equipment used throughout industry, commerce and in the home. Typically, the purpose of these semi-conductor devices is for monitoring and controlling industrial equipment, eg speed controls for small motors and temperature controls, along with extensive use in computers, VDUs, printers, washing machines, etc. As the equipment is fed from the mains electrical supply, in the event of an earth fault the presence of semi-conductors may result in the normal ac waveform being replaced by a non-sinusoidal fault current. In some cases the waveform may be rectified or chopped. These waveforms are said to contain a pulsating dc component which can either partially desensitise or totally disable a standard Type AC RCD. New International standards IEC 1008 (RCCBs) and IEC 1009 (RCBOs) divide RCDs into two performance classes:

To ensure the correct level of protection, check for the following symbols: TYPE AC normal ac sensitivity

TYPE A pulsating dc sensitivity

Type AC RCDs for which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly arising. Type A RCDs for which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly arising.

Wylex RCDs are available as both Type AC and Type A devices.


BOX DIMENSIONS A=230mm(9"),B=239mm(9.6"),C=120mm(4.7") 10 MODULE

INSULATED B

A

NHRM204/40 NHRM204/63 NH4ED4

BOX DIMENSIONS A=230mm(9"),B=187mm(7.5"),C=120mm(4.7") 7 MODULE

NH1104 NHRS1104 NHRM1104 NHSTM3604 NHSTM4504 NHSTM5404 NHSTM6304 NHRS5404 NHRS4504 NHRS9SL

BOX DIMENSIONS A=230mm(9"),B=340mm(13.5"),C=120mm(4.7") 16 MODULE

NH1404 NHRS1404 NHRM1404 NHSTM3904 NHSTM4804 NHSTM5704 NHSTM6604 NH11X3904 NH11X4804

NHRM504 NHTM504 NH7ED4

NHRS3604 NHRS6304 NHIIX5404 NHIIX4504 NH804+3 NHRS804+3 NHRM804+3 NHTM1104 NH13ED4

NH804+6 NH1104+3 NHRS804+6 NHRS1104+3 NHRM804+6 NHRM1104+3 NH16ED4 NHISS5504

37

BOX DIMENSIONS A=230mm(9"),B=435mm(17.3"),C=120mm(4.7") 21 MODULE

NH1904 NHRS1904 NHRM1904 NHSTM12504 NHSTM11604 NHSTM8904 NHSTM9804 NHSTM10704 NHSTM71004 NHSTM61104 NHSTM51204 NHRS12504 NHRS11604 NHRS10704 NHRS61104 NHRS17SL

NHRS9304 NHIIX7504 NHIIX6604 NHIIX5704 NHRSX5704 NHRSX6604 NHRSX7504 NHTM1404

NHRS71004 NHRS9804 NHRS8904 NHRS51204 NHIIX9804 NHIIX8904 NHRSX8904 NHRSX9804 NHRS6504+6 NHRS5604+6 NHRS7704+3 NHRS8604+3 NHRS6804+3 NHTM1904 NH21ED4 NHISS8704 NHIIX11604 NHIIX51204

SINGLE METAL 121 90

146

209.5

D

E

BOX DIMENSIONS D=292mm(11.5"), E=210mm(8.3") 13 MODULE

BOX DIMENSIONS D=438mm(17.2"), E=235.7mm(10.1") 21 MODULE

NHRM1106 NHSTM3606 NH1106 NHRS4506 NHSTM5406 NH806+3 NHRS5406 NHRS9SLM NH11X2406

NH1906 NHRS61106 NHRS9806 NHRS17SLM NHSTM9806 NH21ED6 NHSTM8906

NHRS806+3 NHRS1106 NHRS806+3 NHRS5406 NH13ED6 NHSTM4506 NHRS6306 NHTM1106 NH11X3306

BOX DIMENSIONS 209(H) 117(W) 90(D) 120(D) 4 MODULE

BOX DIMENSIONS D=353mm(13.5"), E=260mm(10.2") 16 MODULE

NH206/40 NH206/63

NH1406 NHRS1106+3 NHRS4806 NHRS1406 NHRM1106+3 NHRS6606 NHRM1406 NH806+6 NHRS7506

NHRS206/40 NHRS206/63

BOX DIMENSIONS D=188mm(7.4"), E=107mm(4.2") 7 MODULE

NH506 NHTM506 NH7ED6

NHRS506 NHRM506

DUPLEX METAL

G

450

121 90.4

295

F

NHSTM6606 NHRS3906 NHSTM7506 NHRM806+6 NHTM1406 NHRS12SLM NH16ED6 NH1106+3 NHSTM8406

NHRS1906 NHRS8906 NHSTM71006 NHSTM9806 NHRS5606+6 NHTM1906 NHIIX51206 NHIIX11606

BOX DIMENSIONS D=241mm(9.5"), E=160mm(6.3") 10 MODULE

NHRM806 NH10ED6 NHRS2406 NHRS3306 NHRS4206 NHRS6SLM

NH806 NHRS806 NHSTM2406 NHSTM3306 NHTM806

BOX DIMENSIONS F=241mm(9.5"), G=160mm(6.3")

BOX DIMENSIONS F=343mm(13.5"), G=260mm(10.2")

NHDIS88 NHDTMS88 NHDIIX88

NHDIS1414 NHDTMS1414 NHDIIX1414

NHDISX88 NHDSSX88

NHDISX1414 NHDSSX1414

BOX DIMENSIONS F=292mm(11.5"), G=210mm(8.3")

BOX DIMENSIONS F=430mm(17.2"), G=235.7mm(10.1")

NHDIS1111 NHDTMS1111 NHDIIX1111

NHDIS1919 NHDTMS1919 NHDIIX1919

NHDISX1111 NHDSSX1111

NHDISX1919 NHDSSX1919

STANDARDS Switches BS EN 60947-3. Double pole 240V 50Hz. Category of duty AC21. Consumer units BS EN 60439-3. RCDs BS EN 61008. Degree of protection IP2X. RCBOs BS EN 61009.

NH Range Dimensions

BOX DIMENSIONS A=160mm(6.3"),B=117mm(4.6"),C=102mm(4") 4 MODULE

NH504 NHRS504

NHRS3304 NHRS4204 NH504+3 NHRS504+3 NHRM504+3 NHTM804 NH10ED4 NH11X3304

BOX DIMENSIONS A=230mm(9"),B=290mm(11.5"),C=120mm(4.7") 13 MODULE

C

NH204/40 NH204/63 NHRS204/40 NHRS204/63

NH804 NHRS804 NHRM804 NHSTM2404 NHSTM3304 NHSTM4204 NHRS2404 NH11X2404 NHRS6SL

NHSTM7504 NHSTM8404 NHSTM9304 NHRS3904 NHRS4804 NHRS6604 NHRS5704 NHRS7504 NHRS8404 NHRS12SL


STANDARD RANGE A

INSULATED-MAIN SWITCH ISOLATOR CAT REF

Standard Range – Dimensions

38

104 204 304 404 604 804

B FUSES

A

DIMENSIONS B

C

98

121

68

125

120

70

190

155

95

190

155

95

272

186

103

323

186

103

C

METAL-45A AND 60A SWITCHFUSES

METAL-MAIN SWITCH ISOLATOR

A

CAT REF

108/160 206 306 406 606

B

CAT REF A

DIMENSIONS B

C

106

112

131

80

108M/160CM

172

242

98

A

DIMENSIONS B

C

143

178

99

140

131

93

210

153

99

210

153

99

METAL-100A DOUBLE POLE SWITCHFUSE

293

210

104

CAT REF

C

A

DIMENSIONS B

C

110M 110M/80

178

305

76

178

305

76

110M/63

178

305

76

ENCLOSURES

CAT REF

DIMENSIONS IP RATING A

ESE2 ESE2L WBE3 ESI4 ESM6 ESM7 ESE4 WBE4 ESM11 ESM13 ESM8

B

A

IP40 IP20 IP65 IP40 IP40 IP54 IP20 IP65 IP54 IP54 IP40

60 60 85 100 90 90 77 110 120 137 120

B 153 140 160 150 225 225 140 160 225 318 225

ISOLATORS

CAT REF A

B

A

C

DIMENSIONS B C

Terminal Capacity

CAT REF A

DIMENSIONS B C

Terminal Capacity

832A

62

76

30

10

910E

178

305

76

70

860A

57

79

29

25

921X

72

45

48

10

810X

53

94

77

35

921E

114

133

61

10

810A

58

170

77

35

REC2S

78

150

65

50

810E

76

203

76

35

REC2

100

150

65

50

REC3

100

150

65

50

REC4

100

150

65

50


TECHNICAL INFORMATION Sheet Steel Enclosure RATING IN AMPS

32A

40A

63A

63A*

100A

125A

800

800

800

800

800

800

800

Dielectric Strength (kV) 50 Hz 1min

3

3

3

3

3

3

3

Shock Resistance Uimp (kV)

8

8

8

8

8

8

8

20

32

40

63

80

100

125

AC22A / AC22B

20

32

40

63

80

100

125

AC23A / AC23B

20

32

40

63

80

80

80

500 V AC - AC21A / AC21B

20

32

40

63

80

100

125

AC22A / AC22B

20

32

40

63

80

100

125

AC23A / AC23B

20

32

40

40

63

63

63

690 V AC - AC20A / AC20B

20

32

40

63

80

100

125

AC21A / AC21B

20

32

40

63

80

100

125

AC22A / AC22B

20

32

40

63

80

100

100

AC23A / AC23B

20

25

25

25

50

50

50

Rated Insulation Voltage Ui (V)

OPERATIONAL CURRENT IE (A) 415 V AC - AC21A / AC21B

MOTOR POWER (KW) AC 23 415 V AC

7.5

11

11

15

18.5

37

40

500 V AC

7.5

11

15

18.5

22

37

37

690 V AC

11

11

18.5

18.5

25

30

30

FUSE TYPES TO BS88 OVERLOAD CAPACITY Fuse rating gG

20

32

40

63/40

63

100

125

Short circuit current with fuses (kA Rms)

50

50

50

20/50

50

20

15

Asymmetric short time rating current (kA peak)

6

6

6

9

9

9

9

Admissible short time current 1 s. (kA Rms)

1.26

1.26

1.26

1.5

1.5

1.5

1.5

MAKING & BREAKING CHARACTERISTICS Breaking capacity (A Rms) 415 V AC 23 A Making capacity (A Rms) 415 V AC 23 A

160

256

320

504

504

640

640

200

320

400

630

630

800

800

WITHSTAND Mechanical (number of operations) x 1000 Electrical (number of operations at 415V AC 23A) x 1000

100

100

100

100

30

30

30

3

3

3

3

1.5

1.5

1.5

16

16

16

16

50

50

50

WEIGHT (KG) 3 pole

2.00

2.00

2.00

2.00

2.50

2.50

2.50

4 pole

2.00

2.00

2.00

2.00

2.50

2.50

2.50

CONNECTION Maximum Cu cable section (mm2) Ith using stranded cable (mm2)

DIMENSIONS D

A

C

B

STEEL ENCLOSURES BOX

A

B

C

D

1

220

158

136

172.5

2

325

158

136

172.5

* Box size 2 steel enclosed switch. Dimensions are overall including screw heads.

39 NH Switch Disconnectors

20A


STANDARDS

NH MCB Distribution Boards

40

CONSTRUCTION

Switches

Multipole: 415V 50Hz BSEN 60947-3 1992 Category of duty AC22A

MCBs

BSEN 60898: 1991 Type B, C and D 6 & 10kA

Short circuit rating

Distribution Boards BS EN 60439-3 Degree of Protection.

For indoor use only (IP3X)

The WYLEX PSB miniature circuit breakers are rated at 10kA and are of the fault limiting type.

430mm

125A DISTRIBUTION BOARDS

A

*144mm

Enclosure Top View

107mm

Cover & Door Top View

37mm

DIMENSION A mm

NHTN4 NHTN6 NHTN8 NHTN12 NHTN16 NHTN20 NHTN24

488.4 569.4 650.4 812.4 893.4 974.4 1136.4

CAT REF

NHTN2540 NHTN2560 NHTN2580 NHTN25120 NHTN25160 NHTN25200 NHTN25240 C

630

Height

A

20 20 23 26 20 20 23 26

210 210 210 210 210 210

B mm

C mm

188 242 293 343 394 394

105 105 105 105 105 105

DIMENSION A mm 650 815 815 895 975 1085 1190

HEIGHT (mm)

A(mm)

902 902 1060 902 902 1060

420 420 420 420 420 420

CAT REF

HEIGHT (mm)

A(mm)

CAT REF

1060 1060 1317 1375 1060 1060 1317 1375

577.5 577.5 577.5 577.5 577.5 577.5 577.5 577.5

NHPB6SW400 NHPB8SW400 NHPB12SW400 NHPB16SW400 NHPB6CB400 NHPB8CB400 NHPB12CB400 NHPB16CB400

NHPB6SW250 NHPB8SW250 NHPB12SW250 NHPB6CB200 NHPB8CB200 NHPB12CB200

NH125 MODULAR MCB/DIN ENCLOSURES MODULAR HEIGHT

Height

NHSN51 NHSN81 NHSN111 NHSN141 NHSN161 NHSN191

400A PANEL BOARDS MODULAR HEIGHT

630

DIMENSIONS A mm

200A-250A PANEL BOARDS 17 17 20 17 17 20

Top View

CAT REF

Depth 155mm- all sizes

MODULAR HEIGHT

164.5

SINGLE PHASE DISTRIBUTION BOARDS

CAT REF

* including fixing feet which are 3.5mm high

B

When a short circuit occurs, the current operates a solenoid which trips the mechanism and forces the moving contact away from the fixed contact. The arc generated is forced into an arcing chamber which incorporates splitter plates, to divide and cool it, reducing the total operating time to less than 5ms, This high speed operation substantially reduces the ‘let through’ energy (I2 t) keeping additional damage at the point of the fault to a minimum. Additionally this allows discrimination with HRC fuses at high fault levels.

250A DISTRIBUTION BOARDS

A

NHG125 MCCB Panelboards

Wylex NH MCB distribution board enclosures are fabricated in heavy gauge steel and are rust protected and highly resistant to both weathering and mechanical damage. Incorporated in the distribution boards are multi-terminal dual earth and neutral bars. They are designed for ease of installation and have ample wiring space.

HEIGHT (mm)

CAT REF

4

*210

TO ORDER

8

*420

TO ORDER

* Dimensions for Accessory boxes do not include end plate dimensions, this is because these 2 boxes are add on units and are supplied without end plates. The end plate is removed from the panel board, that is connected to the add on unit. Then fitted to the top of the add on unit. 164.5

Top View


NHG MCCBs TECHNICAL SPECIFICATION 7

10

NHG MCCB SPECIFICATION • Specification

6

10

BSEN60947-2

• Current Range

25 – 125A

• Ue Rated Operation Voltage

240V SP 415V TP

• Ui Rated Insulation Voltage

500V AC

• Rated Frequency

50/60Hz

41

2

5

10

4

10 1,000

10,000

• Release

Thermal Magnetic

• Adjustment

None

• Ambient Range

-20°C to 55°C

• Humidity Range

0 – 90%

• Weight

SP - 0.4kg TP - 0.95kg

• Mechanical Duration

8000 operations

NHG Panelboard MCCBs

It

100,000

PROSPECTIVE CURRENT

SHORT CIRCUIT BREAKING CAPACITY

AUXILIARY EQUIPMENT

Type Ue

NHG MCCBs Auxiliary Contact Ratings (A) Voltage Resistive Tungsten Load Inductive

220 V 380 V 415 V Ics = 50% Icu

GB Icu SP/TP 30 16 16

GN Icu TP 30 25 25

AC 125 250 DC 30 50 125

INSTANTANEOUS TRIP BANDS 25 – 32A 40 – 80A 100 – 125A Non-adjustable

SP 500A 800A 1250A

TP 400A 600A 600A ±10%

Load (A)

NC (A)

NO (A)

Load (A)

3 3

0.5 0.5

0.5 0.5

3 3

3 1 0.5

3 0.7 0.4

0.5 0.7 0.4

3 1 0.05

TERMINALS Front-connected clamps – 25A to 125A – 70mm2 cable – 10mm strip

MAXIMUM EARTH LOOP IMPEDANCES FOR TRIPLE POLE MCCBS Zs (ohms) for Uo = 240V~ Current Rating (A) 25 32 40 50 63 0.4 Seconds Disconnection Time 0.17Ω 0.17Ω 0.13Ω 0.13Ω 0.13Ω 5.00 Seconds Disconnection Time 0.96Ω 0.75Ω 0.60Ω 0.48Ω 0.38Ω

80 0.13Ω 0.30Ω

100 0.13Ω 0.24Ω

125 0.13Ω 0.19Ω

MAXIMUM EARTH LOOP IMPEDANCES FOR SINGLE POLE MCCBS Zs (ohms) for Uo = 240V~ Current Rating (A) 25 32 40 50 63 0.4 Seconds Disconnection Time 0.43Ω 0.43Ω 0.27Ω 0.27Ω 0.27Ω 5.00 Seconds Disconnection Time 0.96Ω 0.75Ω 0.60Ω 0.48Ω 0.38Ω

80 0.27Ω 0.30Ω

100 0.17Ω 0.24Ω

125 0.17Ω 0.19Ω

Interphase Barriers 78.50

Terminals Suitable for 10mm Strip or 70mm2 Cable

33.50

30.00

26.25 26.25 Phase Ctrs Phase Ctrs 26.00 Use M3 Fasteners

94.00 Fixing Ctrs

120.00

120.00

74.00 Fixing Ctrs

I T

O R

Use M4 Fasteners 19.50 Fixing Ctrs

26.25 Fixing Ctrs

70.50 77.50 83.50 97.00 max

Operating Lever Positions 'I' Breaker Closed 'O' Breaker Open 'T' Breaker Tripped by Release 'R' Reset Positions from Tripped


CONTACTORS TYPE

POWER (W) C( yF)

Incandescent Lamps

MESB Contactors

42

Flourescent Lamps uncorrected and Series correction Flourescent Lamps lea d - lag circuit

Flourescent Lamps Parallel correction

Flourescent Lamps with electronic ballast units (EVG)

Hig h - pressure Mercury - vapour Lamps uncorrected

High Pressure Mercury - vapour Lamps Parallel correction

Halogen meta l - vapour Lamps uncorrected

Halogen meta l - vapour Lamps Parallel correction

Hig h - pressure Sodiu m - vapour Lamps uncorrected

Hig h - pressure Sodiu m - vapour Lamps parallel

Lo w - pressure Sodium - vapour Lamps uncorrected

Lo w - pressure Sodium - vapour Lamps Parallel correction

60 100 200 500 1000 18 24 36 58 18 24 36 58 18 24 36 58 1 x 18 1 x 36 1 x 58 2 x 18 2 x 36 2 x 58 50 80 125 250 400 700 1000 50 80 125 250 400 700 1000 35 70 150 250 400 1000 2000 35 70 150 250 400 1000 2000 150 250 400 1000 150 250 400 1000 18 35 55 90 135 180 18 35 55 90 135 180

4.5 4.5 4.5 7 7 8 10 18 25 45 60 6 12 20 33 35 95 148 20 33 48 106 5 20 20 26 45 40

I(A) 0.26 0.43 0.87 2.17 4.35 0.37 0.35 0.43 0.67 0.11 0.14 0.22 0.35 0.12 0.15 0.2 0.32 0.09 0.16 0.25 0.17 0.32 0.49 0.61 0.8 1.15 2.15 3.25 5.4 7.5 0.28 0.41 0.65 1.22 1.95 3.45 4.8 0.53 1 1.8 3 3.5 9.5 16.5 0.25 0.45 0.75 1.5 2.5 5.8 11.5 1.8 3 4.7 10.3 0.83 1.5 2.4 6.3 0.35 1.5 1.5 2.4 3.5 3.3 0.35 0.31 0.42 0.63 0.94 1.16

Thermal Rating per Pole MESB - 20NC MESB - 24NC MESB - 40NC MESB - 63NC

MESB - 20NO MESB - 24NO MES B - 40NO MESB - 63NO

20 24 40 63

MESB - 20NC MESB - 20NO

2 2 2 2

23 14 7 3 1 22 22 17 14 x 30 x 24 x 17 x 10 7 7 7 4 25 15 14 12 7 7 14 10 7 4 2 1 1 4 4 3 1 1 18 10 5 3 3 1 5 2 1 5 3 2 1 22 7 7 4 3 3 6 1 1 1 -

MES B - 24NC MESB - 24NO

2 2 2 2

29 16 8 3 1 24 24 20 17 x 40 x 31 x 24 x 14 8 8 8 5 35 20 19 17 10 9 18 13 9 5 3 2 1 5 5 4 2 1 22 12 7 4 3 1 6 3 1 1 1 6 4 2 1 1 1 27 9 9 5 4 4 7 1 1 1 -

MES B - 40NC MESB - 40NO

MESB - 63NC MESB - 63NO

65 40 20 8 4 90 90 65 45 2 x 100 2 x 78 2 x 65 2 x 40 48 48 48 31 100 52 50 50 26 25 38 29 20 10 7 4 3 31 27 22 12 9 5 4 43 23 12 7 6 2 1 36 18 11 6 6 2 1 17 10 6 3 11 6 4 2 71 23 23 14 10 10 44 11 11 8 4 5

85 50 25 10 5 140 140 95 70 2 x 150 2 x 118 2 x 95 2 x 60 73 73 73 47 140 75 72 70 38 36 55 42 29 15 10 6 4 47 41 33 18 13 7 5 60 32 18 10 9 3 1 50 25 15 9 8 3 2 22 13 8 3 16 10 6 3 90 30 30 19 13 13 66 16 16 12 7 8

Motor Rating AC3 (kW) 230V 400V 1.3 2.2 4 5.5 11 8.5 15

AC Ratings in accordance with BSEN6094 7 - 5 - 1 and BSEN 60947 - 4 - 1 Definitions: AC1 Primarily Resistive Load but may be slightly inductive AC3 Medium-Starting-duty motors, starting and switching off of squirrel-cage motors


DIMENSION DETAILS

D inc handle W

D Spreader Box W

43

D

HOUSED UNIT DIMENSIONS (mm) HOUSED UNIT

H

W

D

D inc. handle

20-32A

220

210

135

200

H

W

D

63-100A

420

262

188

258

SPREADER BOX

105

262

183

125-200A

525

315

240

273

SPREADER BOX

105

315

210

315-400A

735

420

240

305

SPREADER BOX

210

420

240

Ø20

Ø25

Ø25

Ø20

Ø32

Ø40

SPECIFICATION ●

BSEN947-3

Range of ratings 20A-400A

Pole configurations SP & N, and TP & N

Voltage rating 415V ac

Frequency rating 50/60 Hz

Fuse type BS88

20/32A Gland Plates

All Dimensions in mm

63-100A Gland Plates

TECHNICAL DATA 20–32A

63A

100A

125A

160A

200A

315A

400A

10,000

10,000

10,000

10,000

10,000

10,000

10,000

10,000

80

80

80

80

80

80

80

80

Ratings

A kW

A kW

A kW

A kW

A kW

A kW

A kW

A kW

415V le/pe

32 15

63 30

100 55

125 75

160 90

200 110

315 160

400 220

-

NHCIL2

NHCIL3

NHCIL3

NHCIL3

NHCIL3

NHCIL4

NHCIL4

Mechanical Endurance Fused s/c Current kA RMS

Isolator links

FUSE COMPARISON DATA CURRENT RATING

BS 88 REFERENCE

LAWSON

GEC

A1

NIT

NIT

NITD

63A

A3, A2

TIS

TIS

BAO

100A

A4

TCP

TCP

CEO

125A

A4

CTFP

TCP

DEO

160A

A4

CTFP

TCP

DEO

200A

A4

CTFP

TCP

DEO

315A

B3

TKF

TKF

ED

400A

B4, B3, B2,B1

TFM

TFM

ED

20/32A

BUSSMAN

NH Fuse Combination Units

H

H


Numeric Index

44

List No 104 106 108 204 206 304 306 404 406 604 606 804 106 RED 108M 110M 110M/63 110M/80 145CM 160C 160CM 3TPBP 921E 921X B10 B16 B20 B32 B40 B6 C15 C20 C30 C35 C40 C45 C5 CFL05 CFL10 CFL15 CFL20 CFL30 CFL35 CFL40 CFL45 EIU ESE2 ESE2L ESE4 ESM11 ESM13 ESM6 ESM7 ESM8 FALNH10SL FALNH1106 FALNH15SL FALNH706 FALNHIIX10SL FALNHRS1106 FALNHRS706 FC FWC L45 L60 LFL100 LFL45 LFL60 LFL80 M10 MAT1 MCBLDX MDT2 MESB-20NO (NC) MESB-24NO (NC) MESB-40NO (NC) MESB-63NO (NC) MSTT-111 MSTT-227 MSTU6011R MSTU6011S MSTU6112R MSTU8011R MSTU8011S MSTU8112R MTS8

Page No 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 13 31 31 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 9 29 29 29 29 29 29 29 29 8 8 8 8 8 8 8 25 25 25 25 25 25 25 25 25 9 13 9 9 9 9 9 9 9 9 9 9 9 9 9 9

List No NH00 NH00 NH10ED4 NH10ED6 NH100HP NH1104 NH1104+3 NH1106 NH1106+3 NH13ED4 NH13ED6 NH1404 NH1406 NH16ED4 NH16ED6 NH1904 NH1906 NH200TPSW NH204/40 NH204/63 NH206/40 NH206/63 NH21ED4 NH21ED6 NH304IP NH4ED4 NH4ED6 NH4PINKIT NH504 NH504+3 NH506 NH506+3 NH704IP NH7ED4 NH7ED6 NH8+3 NH8+6 NH804 NH804+3 NH804+6 NH806 NH806+3 NH806+6 NHAB NHAB2 NHAB3 NHAB4 NHAB5 NHCBDK11 NHCBDK12 NHCBDK15 NHCEKIT NHCEKIT20 NHCL NHCSB NHDIIX1111 NHDIIX1414 NHDIIX1919 NHDIIX88 NHDIS1111 NHDIS1414 NHDIS1919 NHDIS88 NHDISX1111 NHDISX1414 NHDISX1919 NHDISX88 NHDPDC NHDSSX1111 NHDSSX1414 NHDSSX1919 NHDSSX88 NHDTMS1111 NHDTMS1414 NHDTMS1919 NHDTMS88 NHEB NHEP11 NHFHDK17 NHFHDK20 NHG13DB NHGAB NHGPCB1001 NHGPCB1003 NHGPCB1251

Page No 9 13 29 29 5 3 3 6 7 29 29 3 6 29 29 3 6 13 3 3 6 6 29 20 5 29 29 13 3 3 6 7 5 29 29 12 12 3 3 3 6 7 7 13 13 13 13 13 18 18 18 13 13 13 17 8 8 8 8 8 8 8 8 8 8 8 8 13 8 8 8 8 8 8 8 8 13 13 17 17 18 17 19 19 19

List No NHGPCB1253 NHGPCB251 NHGPCB253 NHGPCB321 NHGPCB323 NHGPCB401 NHGPCB403 NHGPCB501 NHGPCB503 NHGPCB631 NHGPCB633 NHGPCB801 NHGPCB803 NHIIX11604 NHIIX11606 NHIIX2404 NHIIX2406 NHIIX3304 NHIIX3306 NHIIX3904 NHIIX4504 NHIIX4506 NHIIX4804 NHIIX51204 NHIIX51206 NHIIX5404 NHIIX5406 NHIIX5704 NHIIX5706 NHIIX6604 NHIIX6606 NHIIX7504 NHIIX7506 NHIIX8904 NHIIX8906 NHIIX9804 NHIIX9806 NHISS3406 NHISS4606 NHISS5504 NHISS5506 NHISS8704 NHISS8706 NHPB12CB200 NHPB12CB400 NHPB12SW250 NHPB12SW400 NHPB16CB400 NHPB16SW400 NHPB6CB200 NHPB6CB400 NHPB6SW250 NHPB6SW400 NHPB8CB200 NHPB8CB400 NHPB8SW250 NHPB8SW400 NHPBDL NHPCB1TS NHPCB3TS NHPCBAU1 NHPCBAU2 NHPCBL NHPCBLDX NHRM1104 NHRM1104+3 NHRM1106 NHRM1404 NHRM1406 NHRM1904 NHRM1906 NHRM204/40 NHRM204/63 NHRM206/40 NHRM206/63 NHRM504 NHRM504+3 NHRM506 NHRM804 NHRM804+3 NHRM804+6 NHRM806 NHRS1004IP NHRS10704 NHRS10706

Page No 19 19 19 19 19 19 19 19 19 19 19 19 19 3 7 3 7 3 7 3 3 7 3 3 7 3 7 3 7 3 7 3 7 3 7 3 7 8 8 5 8 5 8 17 18 17 18 18 18 17 18 17 18 17 18 17 18 13 19 19 19 19 19 19 3 3 6 3 6 3 6 3 3 6 6 3 3 6 3 3 3 6 5 4 6

List No NHRS1104 NHRS1104+3 NHRS1106 NHRS1106+3 NHRS11604 NHRS11606 NHRS12504 NHRS12506 NHRS12SL NHRS12SLM NHRS1404 NHRS1406 NHRS17SL NHRS17SLM NHRS1904 NHRS1906 NHRS204/40 NHRS204/63 NHRS206/40 NHRS206/63 NHRS2404 NHRS2406 NHRS304IP NHRS3304 NHRS3306 NHRS3604 NHRS3606 NHRS3904 NHRS3906 NHRS4204 NHRS4206 NHRS4504 NHRS4506 NHRS4804 NHRS4806 NHRS504 NHRS504+3 NHRS506 NHRS506+3 NHRS51204 NHRS51206 NHRS5404 NHRS5406 NHRS5604+6 NHRS5606+6 NHRS5704 NHRS5706 NHRS61104 NHRS61106 NHRS6304 NHRS6306 NHRS6504+6 NHRS6604 NHRS6606 NHRS6804+3 NHRS704IP NHRS71004 NHRS71006 NHRS7504 NHRS7506 NHRS7704+3 NHRS7706+3 NHRS804 NHRS804+3 NHRS804+6 NHRS806 NHRS806+3 NHRS806+6 NHRS8404 NHRS8406 NHRS8604+3 NHRS8904 NHRS8906 NHRS9304 NHRS9306 NHRS9804 NHRS9806 NHRS9SL NHRS9SLM NHRSX5704 NHRSX5706 NHRSX6604 NHRSX6606 NHRSX7504 NHRSX7506

Page No 3 3 6 7 4 6 4 6 4 7 3 6 4 7 3 6 3 3 6 6 4 6 5 4 6 4 6 4 6 4 6 4 6 4 6 3 3 6 7 4 6 4 6 4 7 4 6 4 6 4 6 4 4 6 4 5 4 6 4 6 4 7 3 3 3 6 7 7 4 6 4 4 6 4 6 4 6 4 7 3 7 3 7 3 7


Page No 3 7 3 7 12 12 12 12 12 12 13 21 21 21 21 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 4 7 21 21 21 21 21 21 21 3 6 3 6 3 6 3 6 3 6 12 12 12 12 12 12 12 12 12

List No NHTN2540 NHTN6 NHTN2560 NHTN8 NHTN2580 NHTPDC NHTPSF100 NHTPSF20 NHTPSF200 NHTPSF32 NHTPSF400 NHTPSF63 NSB06 NSB06-B NSB06-C NSB06-D NSB10 NSB10-B NSB10-C NSB10-D NSB16 NSB16-B NSB16-C NSB16-D NSB20 NSB20-B NSB20-C NSB20-D NSB306-B NSB306-C NSB306-D NSB310-B NSB310-C NSB310-D NSB316-B NSB316-C NSB316-D NSB32 NSB320-B NSB320-C NSB320-D NSB32-B NSB32-C NSB32-D NSB332-B NSB332-C NSB332-D NSB340-B NSB340-C NSB340-D NSB350-B NSB350-C NSB350-D NSB363-B NSB363-C NSB363-D NSB40 NSB40-B NSB40-C NSB40-D NSB50 NSB50-B NSB50-C NSB50-D NSB63-B NSB63-C NSB63-D NSBS10/1 NSBS10/2 NSBS16/1 NSBS16/2 NSBS20/1 NSBS20/2 NSBS32/1 NSBS32/2 NSBS40/1 NSBS40/2 NSBS6/1 NSBS6/2 NSC05 NSC10 NSC15 NSC20 NSC30 NSC35

Page No 12 12 12 12 12 13 21 21 21 21 21 21 9 14 14 14 9 14 14 14 9 14 14 14 9 14 14 14 14 14 14 14 14 14 14 14 14 9 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 9 14 14 14 9 14 14 14 14 14 14 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9

List No NSC40 NSC45 PDDPL PSB06-B PSB06-C PSB06-D PSB10-B PSB10-C PSB10-D PSB16-B PSB16-C PSB16-D PSB206-B PSB206-C PSB206-D PSB20-B PSB20-C PSB20-D PSB210-B PSB210-C PSB210-D PSB216-B PSB216-C PSB216-D PSB220-B PSB220-C PSB220-D PSB232-B PSB232-C PSB232-D PSB240-B PSB240-C PSB240-D PSB250-B PSB250-C PSB250-D PSB263-B PSB263-C PSB263-D PSB306-B PSB306-C PSB306-D PSB310-B PSB310-C PSB310-D PSB316-B PSB316-C PSB316-D PSB320-B PSB320-C PSB320-D PSB32-B PSB32-C PSB32-D PSB332-B PSB332-C PSB332-D PSB340-B PSB340-C PSB340-D PSB350-B PSB350-C PSB350-D PSB363-B PSB363-C PSB363-D PSB40-B PSB40-C PSB40-D PSB50-B PSB50-C PSB50-D PSB63-B PSB63-C PSB63-D PSBL1 PSBL3 PSBS10/1 PSBS10/2 PSBS16/1 PSBS16/2 PSBS20/1 PSBS20/2 PSBS32/1 PSBS32/2

Page No 9 9 13 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 13 13 15 15 15 15 15 15 15 15

List No PSBS40/1 PSBS40/2 PSBS50/1 PSBS6/1 PSBS6/2 PSDL PSDPL R15 R20 R30 R5 REC2 REC2S REC3 REC4 WBE/BS WBE3 WBE3/EK WBE3/NK WBE4 WBE4/EK WBE4/NK WME/FB WPL WRDM100/2 WRDM100/4 WRDM40/2 WRDM40/4 WRDM63/4 WRDS100/2 WRDS100/4 WRDS40/2 WRDS40/4 WRDS63/2 WRDS63/4 WRDS80/2 WRDVS32/2 WRL100/2 WRL100/4 WRL63/2 WRL63/4 WRM100/2 WRM100/4 WRM40/2 WRM40/4 WRM63/2 WRM63/4 WRM80/2 WRMT100/2 WRMT100/4 WRS100/2 WRS100/4 WRS16/2 WRS25/2 WRS32/2 WRS32/4 WRS40/2 WRS40/4 WRS63/2 WRS63/4 WRS80/2 WS101 WS102 WS102 WS103 WS103 WS104 WS104 WS121 WS122 WS122 WS123 WS123 WS124 WS124 WS601 WS602 WS603 WS604 WSB1

Page No 15 15 15 15 15 13 13 25 25 25 25 31 31 31 31 29 29 29 29 29 29 29 29 13 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 31 13 31 13 31 13 31 31 13 31 13 31 13 31 31 31 31 31 9

45 Numeric Index

List No NHRSX8904 NHRSX8906 NHRSX9804 NHRSX9806 NHSN111 NHSN141 NHSN161 NHSN191 NHSN51 NHSN81 NHSPAK NHSPSF100 NHSPSF20 NHSPSF32 NHSPSF63 NHSTM10704 NHSTM10706 NHSTM11604 NHSTM11606 NHSTM12504 NHSTM12506 NHSTM2404 NHSTM2406 NHSTM3304 NHSTM3306 NHSTM3604 NHSTM3606 NHSTM3904 NHSTM3906 NHSTM4204 NHSTM4206 NHSTM4504 NHSTM4506 NHSTM4804 NHSTM4806 NHSTM51204 NHSTM51206 NHSTM5404 NHSTM5406 NHSTM5704 NHSTM5706 NHSTM61104 NHSTM61106 NHSTM6304 NHSTM6306 NHSTM6604 NHSTM6606 NHSTM71004 NHSTM71006 NHSTM7504 NHSTM7506 NHSTM8404 NHSTM8406 NHSTM8904 NHSTM8906 NHSTM9304 NHSTM9306 NHSTM9804 NHSTM9806 NHSW3100 NHSW3125 NHSW320 NHSW332 NHSW340 NHSW363 NHSW363X NHTM1104 NHTM1106 NHTM1404 NHTM1406 NHTM1904 NHTM1906 NHTM504 NHTM506 NHTM804 NHTM806 NHTN12 NHTN25120 NHTN16 NHTN25160 NHTN20 NHTN25200 NHTN24 NHTN25240 NHTN4


ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. eMail: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 01543 455020 Facsimile: 01543 455021 eMail: wylex.sales@electrium.co.uk TECHNICAL Telephone: 01543 438320 Facsimile: 01543 438321 eMail: wylex.technical@electrium.co.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: export@electrium.co.uk DUBAI OFFICE Telephone: +971 4 3660395 Facsimile:+971 4 3660019

DUBLIN OFFICE Telephone: +353 1 4513303 Facsimile:+353 1 4513242

Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, speciďŹ cations and performance data are constantly changing. Latest details can be obtained from Wylex.

Publication No.WY 2013 Printed in England.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.