BY: JENNY BURGER
INTERIOR RENOVATION & EXTERIOR ADDITION
PRELIMINARIES NOT FOR CONSTRUCTION
COMPUTER DRAWING TECHNICIAN
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
7/17/2019
TITLE SHEET SCALE: 1/4" = 1' - 0"
SHEET: 1 OF 5
BY: JENNY BURGER
COMPUTER DRAWING TECHNICIAN
2852DH
5'-10"
19'
2840DH 2840DH
2840DH
17'-7"
12'-10"
5'-3"
2840DH
UNSPECIFIED 481 SQ FT
2680
2680
2040DH 2040DH
19'-5"
13'-9"
3280
APPROX. 106" TO BOTTOM OF DUCT. 20'-1"
PRELIMINARIES NOT FOR CONSTRUCTION
2040DH 2040DH
11'-9"
EXISTING BASEMENT FLOOR PLAN UNFINISHED CEILING HEIGHT117"-14" I JOIST ABOVE INTERIOR DOOR HEIGHTS: 96"
31'-10" 6'-5"
UNSPECIFIED
APPROX. 106" TO BOTTOM OF DUCT.
264 SQ FT
9'-2 1/2"
9'-2 1/2" UNSPECIFIED
UNSPECIFIED 290 SQ FT
3280
24'-1"
2840DH
66'-3"
480 SQ FT
3280
4180
5'-8 1/2" 4'-8"
1'-7"
4'-4"
1'-10"
3280
APPROX. 106" TO BOTTOM OF DUCT.
4'-3"
PIPE 110" TO BOTTOM
7' 13'-1"
5'
4'-8"
3'-5"
13'-1"
1'-6"
UNSPECIFIED
4'-2"
33'-6"
UP
16'-5"
17 STEPS 2680
3080
UNSPECIFIED
ELECTRICAL PANELS 3280
383 SQ FT
WH
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
20'-3"
20'-3"
3280
UNSPECIFIED 221 SQ FT
13'-8"
21'-5"
14'-1 1/2"
4'
16'-4"
2046DH 2046DH
20'-8"
283 SQ FT
430 SQ FT
WH
UTILITY
STORAGE
INTERIOR RENOVATION & EXTERIOR ADDITION
18'-5" 3280
17'-8 1/2"
5'-10"
1'-8"
3080
4'
2680
21'-10"
419 SQ FT
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
7/17/2019 LIVING AREA 3636 SQ FT
EXISTING FLOOR PLAN BASEMENT LOWER LEVEL SCALE: 1/4" = 1' - 0"
SHEET: 2 OF 5
BY: JENNY BURGER
2"
COMPUTER DRAWING TECHNICIAN
W1242L LCW2442L
3DB15
W2742
12'-10"
GYM
11'-3 1/4"
14980
334 SQ FT
3080
HALL 36 SQ FT
BAR
BEDROOM
6'-5"
TV
501 SQ FT
242 SQ FT
8"
APPROX. 106" TO BOTTOM OF DUCT.
4080
CL
198 SQ FT
5080
1'
W1242L
STAIRS 12'-1 1/2"
3080
58 SQ FT
8'-1 1/2"
7' MEDIA ROOM 695 SQ FT
13'-10 1/2"
4'-6" 22'-7"
3DB15
U152496L
7'-6"
2"
2DB331821 2DB331821 4'-4" 2DB331821 2DB331821 2DB331821
COUNTER DEPTH REFRIGERATOR
W382424
4'
14'-10 7/8"
13'-5"
E2
REMOVE WALL, INSTALL HEADER INTO CEILING.
PROJECTION SCREEN
EXISTING PIPE 110" TO BOTTOM
6'
31'-8"
2"
3080
3080
1'-6" 1'-6"
5 1/2"
WINE STORAGE
UP
5080
4'-6"
1'
1'-6"
BLOCKING
10080
54 SQ FT
7" TALL PLATFORM
U482196
4'
HALL
NICHE'
1'-6" 3'-5"
B36
SB3021 3DB1821 SB3021
13'-11"
4'-3"
2'
CONFIRM PLATFORM DEPTHS. CONFIRM CHAIR DIMENSIONS, IF THEY ARE RECLINING OR TO HAVE OTTOMANS, BEFORE CONSTRUCTING PLATFORMS.
7'
CONSTRUCT 7" TALL PERFORMANCE STAGE
REMOVE DOOR WAY FILL WALL
40.5" TALL KNEE WALLGLASS ABOVE
E1 18 RECYCLE 15" ICE
BATH 56 SQ FT
2'-2"
BLOCKING
17 SQ FT
2680
SHOWER
4'
5'-8 5/8"
4" CURB
DROP CEILING OVER SHOWER TO CONCEAL DUCT WORK.
10'-0 1/2"
5'-8 1/2" 4'-8"
BENCH
3080
BLOCKING
BLOCKING 3'
B15
18 SQ FT
8'-1"
28'-6 1/2"
2'
CLOSET
E3
1'
4'-5 1/2"
STEP
14" TALL PLATFORM
W1242L W301224
3'-6 1/2"
LCB36R 3DB15
6080
7'-0 1/2"
OTC332496
MICROWAVE & OVEN
DW
9'-5 1/2"
2'
31'-8"
LCW2442R W2442
40.5" KNEE WALL 1'-6"
INSTALL TRAY TO CONCEAL DUCT WORK.
REMOVE WALL
2840SC
2'-4"
U482196
NEW INTERIOR 2X4 DRYWALL WALL FURRED WALL
16'-5"
ELECTRICAL PANELS
WH
UNFINISHED
1'
INSTALL TRAY TO CONCEAL DUCT WORK.
1"
5670
268 SQ FT
420 SQ FT
UNFINISHED
WH
UTILITY
STORAGE
19'-9"
19'-9"
FILL WALL
15'-10" 13'
21'-5"
13'-7 1/2"
8"
8" 8"
6"
8"
OFFICE 237 SQ FT
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
INSTALL TRAY TO CONCEAL DUCT WORK.
8"
8"
6"
2046SC
2046SC
23'-11"
3080
INSTALL SHELVING IN STORAGE AREA.
INTERIOR RENOVATION & EXTERIOR ADDITION
NEW INTERIOR 2X4 DRYWALL WALL
TRAY 28" X 12"
24'-0 1/2" 3080
NEW INTERIOR 2X6 DRYWALL WALL
7' 5'-3 1/2"
20'-1"
17'-1 1/2"
13'-9"
4080
APPROX. 106" TO BOTTOM OF DUCT.
PRELIMINARIES NOT FOR CONSTRUCTION
DRYER
2840SC
5'-3"
INSTALL TRAY TO CONCEAL DUCT WORK.
SB27
2840SC
11'-2 3/4"
WASHER
EXISTING BASEMENT FLOOR PLAN UNFINISHED CEILING HEIGHT116"-14" I JOIST ABOVE INTERIOR DOOR HEIGHTS: 96" FLOORING: WOOD LOOK (CONFIRM: CERAMIC TILE OR LVT)
11'-10"
2852SC
7'
2840SC
2840SC
12" SOFFIT
LSB36
W2742
U442496
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
7/17/2019 LIVING AREA 3327 SQ FT
PROPOSED BASEMENT FLOOR PLAN SCALE: 1/4" = 1' - 0"
SHEET: 3 OF 5
BY: JENNY BURGER
PRELIMINARIES NOT FOR CONSTRUCTION
3' 4'-6"
4080
WINE
1'-6"
MICROWAVE
8'-8" 9'-8"
3'-6"
COMPUTER DRAWING TECHNICIAN
INTERIOR RENOVATION & EXTERIOR ADDITION
DW
3'-6"
ICE
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
3080
3'
4'-6"
1'-6"
8'-8"
9'-8"
3'-6"
WASTE
3'
10080
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
7/17/2019
PROPOSED BASEMENT BAR ELEVATIONS SCALE: 1/4" = 1' - 0"
SHEET: 4 OF 5
BY: JENNY BURGER
COMPUTER DRAWING TECHNICIAN ELECTRICAL SCHEDULE ATTACHED TO DESCRIPTION COMMENTS UNDER CABINET LIGHT CEILING 5" RECESSED CAN CEILING BAR PENDANT CEILING BED ROOM LIGHT CEILING WINE RM CHANDELIER CEILING EXHAUST CEILING HALL LIGHT CEILING NICHE' LIGHT CEILING OFFICE LIGHT CEILING RECESSED DOWN LIGHT 4 CEILING RECESSED VAPOR LIGHT CEILING STAGE LIGHT CEILING SMOKE DETECTOR FLOOR ADJUSTABLE HEIGHT LAMP FLOOR CLOTHES DRYER FLOOR CLOTHES WASHER FLOOR DISHWASHER FLOOR ELLINGTON FLOOR LAMP FLOOR GAS COOKTOP FLOOR HOOD W/ VENT FLOOR ICE MAKER FLOOR MICROWAVE FLOOR OVEN FLOOR REFRIGERATOR FLOOR SINGLE FLOOR RECEPTACLE, COVERED FLOOR WINE REFRIGERATOR WALL CABLE JACK WALL DUPLEX WALL GFCI WALL QUADRUPLEX WALL SINGLE POLE WALL SINGLE POLE SLIDING DIMMER WALL THEATER SCONCE WALL THREE WAY SLIDING DIMMER WALL VANITY SCONCE
GFCI
GFCI
R
R
R
R
R
CW
R
R
R
GFCI
R
R
CD
CONFIRM FLOOR RECEPTACLE LOCATIONS
DM
3DM
R
R
SD
R
R
PRELIMINARIES NOT FOR CONSTRUCTION
QTY 5 44 3 1 2 1 3 3 1 11 1 5 6 1 1 1 1 1 1 1 1 1 1 1 10 1 6 36 8 10 6 17 10 2 2
C
C
R
R C TV
DM DM
DM
R R
R
R
DM DM DM
SD
R4
R DW
M
R4
R
R
R
R4
R
O
DM DM R4
R4
R
R4
R R4
R4
GFCI
R4
C
R
R4
R H
DM DM
PROJECTION SCREEN
R4
CT
R4
GFCI
R
GFCI
SD
SD
R4
R4
R4
GFCI
UP R
R
R
R
R4
GFCI SD
R
R
R
R
R
DM
R
3DM
DM DM DM
R
ELECTRICAL PANELS DM DM
R
R
R4
CONFIRM CABLE JACK LOCATIONS.
R
WH
R4
WH
SD
R4
C
LIGHTS TO REMAIN THE SAME.
LIGHTS TO REMAIN THE SAME.
R
R
THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.
R
R
INTERIOR RENOVATION & EXTERIOR ADDITION
NUMBER E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 E33 E34 E35
C
SHEET SIZE ANSI D (22" x 34") DATE ISSUED:
7/17/2019
PROPOSED BASEMENT ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1' - 0"
SHEET: 5 OF 5