Caledonian w www.caledonian-cables.co.uk ww.caledonian-cables.co.uk
German Standard (VDE)
www.addison-cables.com
COMPANY PROFILE Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison, produces a wide range of cables for communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.
TABLE OF CONTENT
»» Cables for Underground Mining H07RN-F/A07RN-F 450/750V Harmonized Rubber Cables ������������������������������������������������������������6 H07RN8-F 450/750V Harmonized Rubber Cables �������������������������������������������������������������������������9 NTSWOEU 0.6/1kV E-Loader Cable ����������������������������������������������������������������������������������������������12 NTMTWOEU 0.6/1kV Mine Hoist Cables �������������������������������������������������������������������������������������13 NSHTOEU 0.6/1kV LHD Cables �����������������������������������������������������������������������������������������������������14 NSSHCGEOEU 0.6/1kV Coal Cutter Cable (High Tensile Stress) ����������������������������������������������������15 NSSHCGEOEU 0.6/1kV Coal Cutter Cable (Low Tensile Stress) ����������������������������������������������������17 (N)SSHOEU 0.6/1kV Heavy Duty Flexible Cable ���������������������������������������������������������������������������19 NSSHOEU-O/J 0.6/1kV Heavy Duty Flexible Cable �����������������������������������������������������������������������21 NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable ������������������������������������������������������������23 NSSHOEU/NTSWOEU Submersible Cable Up To 6kv ��������������������������������������������������������������������25 NTSCGERLWOEU 3.6/6kV Flexible Submersible Cable �����������������������������������������������������������������27 NTSKCGERLOEU Medium Voltage Coal Cutter Cable ������������������������������������������������������������������29 NTSCGECWOEU Medium Voltage Coal Cutter Cable ������������������������������������������������������������������31 (N)TSCGECWOEU Medium Voltage Trailing Cable ����������������������������������������������������������������������33 (N)TSCGEWOEU Medium Voltage Trailing Cable With Anti-Torsion Braid �����������������������������������35 NSGAFOEU/NSHXAFOE Medium Voltage Single Core Cables ������������������������������������������������������36 N3GHSSYCY Medium Voltage Cable ���������������������������������������������������������������������������������������������38
»» Cables for Open-cast Mining (N)SHOEU 0.6/1kV Flexible cable �������������������������������������������������������������������������������������������������40 2YSLGCGOEU Signal & Control Cable �������������������������������������������������������������������������������������������43
TABLE OF CONTENT (N)TSCGEWOEU Medium Voltage Reeling Cable Without Fibre Optics ���������������������������������������44 (N)TSCGEWOEU Medium Voltage Reeling Cable With Fiber Optics ��������������������������������������������47 (N)TSCGEWOEU Medium Voltage Fixed Installation Cable Without Fibre Optics ������������������������50 (N)TSCGEWOEU Medium Voltage Fixed Installation Cable With Fiber Optics �����������������������������54 NTSCGEWOEU Medium Voltage Flexible Cable For Use In Water �����������������������������������������������58 NTSCGEWOEU Flexible Medium Voltage Trailing Cable ��������������������������������������������������������������63 NTMCWOEU Flexible Medium Voltage Single Core Cable �����������������������������������������������������������68 NTMCGCWOEU Flexible Medium Voltage Single Core Cable ������������������������������������������������������71 Flexible Fibre Optic cable �������������������������������������������������������������������������������������������������������������74 Reeling Fibre Optic cable �������������������������������������������������������������������������������������������������������������75
»» Technical Information Cable Type Designation ���������������������������������������������������������������������������������������������������������������76 Wire Diameters and Conductor Resistance ���������������������������������������������������������������������������������77
4
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
H07RN-F/A07RN-F 450/750V Harmonized Rubber Cables »» Applications These cables are designed for the connection of heating units, industrial tools, mobile equipment and machines, e.g. vulcanisation plates, hand-operated equipment, transportable motors etc., under normal mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, as well as in industrial and agricultural applications and on building sites.
»» Standards DIN VDE 0282 Part1 and Part 4 HD 22.1 HD 22.4
»» Construction Stranded Copper Conductor EI4 Insulation EM2/EM3 Inner Sheath EM2 Outer Sheath
Conductors: Stranded copper conductor, class 5 according to DIN VDE 0295/HD 383 S2. Insulation: Rubber type EI4 according to DIN VDE 0282 Part 1/HD 22.1. Inner Sheath (for ≥ 10 mm² or more than 5 cores): NR/SBR rubber type EM1. Outer Sheath: CR/PCP rubber type EM2.
»» Dimensions and Weight Number of Cores×Nominal Cross Section No. ×mm² 1×1.5 2×1.5
6
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
mm 0.8 0.8
mm -
mm 1.4 1.5
Minimum Overall Diameter mm 5.7 8.5
www.caledonian-cables.co.uk www.addison-cables.com
Maximum Overall Diameter mm 6.7 10.5
Nominal Weight kg/km 60 120
Caledonian Mining Cables Cables for Underground Mining Number of Cores×Nominal Cross Section No. ×mm² 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 19G1.5 24G1.5 1×2.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 19G2.5 24G2.5 1×4 2×4 3G4 4G4 5G4 1×6 2×6 3G6 4G6 5G6 1×10 2×10 3G10 4G10 5G10 1×16 2×16 3G16 4G16 5G16 1×25 4G25 5G25 1×35
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4
mm 1.0 1.2 1.4 1.4 1.1 1.2 1.5 1.6 1.2 1.3 1.4 1.4 1.3 1.4 1.4 1.5 1.6 1.7 -
mm 1.6 1.7 1.8 1.6 1.7 2.1 2.1 1.4 1.7 1.8 1.9 2.0 1.7 1.9 2.2 2.3 1.5 1.8 1.9 2.0 2.2 1.6 2.0 2.1 2.3 2.5 1.8 1.9 2.0 2.0 2.2 1.9 2.0 2.1 2.2 2.4 2.0 2.2 2.7 2.2
Minimum Overall Diameter mm 9.2 10.2 11.2 14.0 17.6 20.7 24.3 6.3 10.2 10.9 12.1 13.3 17.0 20.6 24.4 28.8 7.2 11.8 12.7 14.0 15.6 7.9 13.1 14.1 15.7 17.5 9.5 17.7 19.1 20.9 22.9 10.8 20.2 21.8 23.8 26.4 12.7 28.9 32.0 14.3
www.caledonian-cables.co.uk www.addison-cables.com
Maximum Overall Diameter mm 11.2 12.5 13.5 17.0 20.5 26.3 28.5 7.5 12.5 13.0 14.5 16.0 20.0 23.5 30.9 33.0 8.5 14.5 15.0 17.0 19.0 9.5 16.0 17.0 19.0 21.0 11.5 21.5 22.5 24.5 27.0 13.0 23.5 25.5 28.0 31.0 15.0 33.0 36.0 17.0
Nominal Weight kg/km 170 210 260 360 515 795 920 75 170 230 290 360 510 740 1190 1525 100 195 305 400 505 130 285 380 550 660 195 565 715 875 1095 280 795 1040 1280 1610 405 1890 2335 545 7
Caledonian Mining Cables Cables for Underground Mining Number of Cores×Nominal Cross Section No. ×mm² 4G35 5G35 1×50 4G50 5G50 1×70 4G70 1×95 4G95 1×120 4G120 5G120 1×150 4G150 1×185 4G185 1×240 1×300 1×630
8
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
mm 1.4 1.4 1.6 1.6 1.6 1.6 1.6 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.2 2.2 2.4 2.6 3.0
mm 1.7 1.8 1.9 2.1 2.0 2.3 2.4 2.8 2.6 2.8 -
mm 2.7 2.8 2.4 2.9 3.1 2.6 3.2 2.8 3.6 3.0 3.6 4.0 3.2 3.9 3.4 4.2 3.5 3.6 4.1
Minimum Overall Diameter mm 32.5 35.0 16.5 37.7 41.0 18.6 42.7 20.8 48.4 22.8 53.0 59.0 25.2 58.0 27.6 64.0 30.6 33.5 45.5
www.caledonian-cables.co.uk www.addison-cables.com
Maximum Overall Diameter mm 36.5 39.5 19.5 42.0 46.0 22.0 47.0 24.0 54.0 26.5 59.0 65.0 29.0 64.0 31.5 71.0 35.0 38.0 51.0
Nominal Weight kg/km 2505 2718 730 3350 3804 955 4785 1135 6090 1560 7550 8290 1925 8495 2230 9850 2945 3495 7020
Caledonian Mining Cables Cables for Underground Mining
H07RN8-F 450/750V Harmonized Rubber Cables »» Applications These cables are designed for use in submersible pumps and similar applications in water for industrial use up to a water depth of 10 m and water temperature-ranges up to 40℃, also approved for dry, humid and wet applications.
»» Standards DIN VDE 0282 Part1 and Part 16 HD 22.1 HD 22.16 S1
»» Construction Stranded Copper Conductor EI4 Insulation EM2/EM3 Inner Sheath EM2 Outer Sheath
Conductors: Stranded copper conductor, class 5 according to DIN VDE 0295/IEC 60228. Insulation: Rubber type EI4 according to DIN VDE 0282 Part 16. Inner Sheath (for ≥ 10 mm² or more than 5 cores): Rubber type EM2/EM3 according to DIN VDE 0282 Part 16. Outer Sheath: Rubber type EM2 according to DIN VDE 0282 Part 16.
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×1.5
mm 0.8
mm -
mm 1.4
mm 5.7
mm 6.7
kg/km 60
www.caledonian-cables.co.uk www.addison-cables.com
9
Caledonian Mining Cables Cables for Underground Mining
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 2×1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 19G1.5 24G1.5 1×2.5 2×2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 19G2.5 24G2.5 1×4 2×4 3G4 4G4 5G4 1×6 2×6 3G6 4G6 5G6 1×10 2×10 3G10 4G10 5G10 1×16 2×16 3G16 4G16 5G16 1×25 4G25
mm 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4
mm 1.0 1.2 1.4 1.4 1.1 1.2 1.5 1.6 1.2 1.3 1.4 1.4 1.3 1.4 1.4 1.5 1.6
mm 1.5 1.6 1.7 1.8 1.6 1.7 2.1 2.1 1.4 1.7 1.8 1.9 2.0 1.7 1.9 2.2 2.3 1.5 1.8 1.9 2.0 2.2 1.6 2.0 2.1 2.3 2.5 1.8 1.9 2.0 2.0 2.2 1.9 2.0 2.1 2.2 2.4 2.0 2.2
mm 8.5 9.2 10.2 11.2 14.0 17.6 20.7 24.3 6.3 10.2 10.9 12.1 13.3 17.0 20.6 24.4 28.8 7.2 11.8 12.7 14.0 15.6 7.9 13.1 14.1 15.7 17.5 9.5 17.7 19.1 20.9 22.9 10.8 20.2 21.8 23.8 26.4 12.7 28.9
mm 10.5 11.2 12.5 13.5 17.0 20.5 26.3 28.5 7.5 12.5 13.0 14.5 16.0 20.0 23.5 30.9 33.0 8.5 14.5 15.0 17.0 19.0 9.5 16.0 17.0 19.0 21.0 11.5 21.5 22.5 24.5 27.0 13.0 23.5 25.5 28.0 31.0 15.0 33.0
kg/km 120 170 210 260 360 515 795 920 75 170 230 290 360 510 740 1190 1525 100 195 305 400 505 130 285 380 550 660 195 565 715 875 1095 280 795 1040 1280 1610 405 1890
10
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Inner Sheath
Thickness of Outer Sheath
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 5G25 1×35 4G35 5G35 1×50 4G50 5G50 1×70 4G70 1×95 4G95 1×120 4G120 5G120 1×150 4G150 1×185 4G185 1×240 1×300 1×630
mm 1.4 1.4 1.4 1.4 1.6 1.6 1.6 1.6 1.6 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.2 2.2 2.4 2.6 3.0
mm 1.7 1.7 1.8 1.9 2.1 2.0 2.3 2.4 2.8 2.6 2.8 -
mm 2.7 2.2 2.7 2.8 2.4 2.9 3.1 2.6 3.2 2.8 3.6 3.0 3.6 4.0 3.2 3.9 3.4 4.2 3.5 3.6 4.1
mm 32.0 14.3 32.5 35.0 16.5 37.7 41.0 18.6 42.7 20.8 48.4 22.8 53.0 59.0 25.2 58.0 27.6 64.0 30.6 33.5 45.5
mm 36.0 17.0 36.5 39.5 19.5 42.0 46.0 22.0 47.0 24.0 54.0 26.5 59.0 65.0 29.0 64.0 31.5 71.0 35.0 38.0 51.0
kg/km 2335 545 2505 2718 730 3350 3804 955 4785 1135 6090 1560 7550 8290 1925 8495 2230 9850 2945 3495 7020
www.caledonian-cables.co.uk www.addison-cables.com
11
Caledonian Mining Cables Cables for Underground Mining
NTSWOEU 0.6/1kV E-Loader Cable »» Applications These cables are used for the connection of mobile machines under extremely high mechanical loads, predominantly in mining situations, also can be operated via guide pulleys (cable cars) or used as a reeling cable (LHD), suitable for extreme bending loads, high tensile stress, and impact and crushing loads. Stranded Tinned Copper Conductor
»» Standards
Optional Special Pilot Cores EPR Insulation
VDE 0250 Part 813
GM1b Rubber Inner Sheath Copper-Steel Wires Braid
»» Construction
5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 6 according to DIN VDE 0295. Insulation: EPR. Pilot Cores (optional): Special conductor, tinned copper braid and galvanised steel wire braid. Inner Sheath: Rubber type GM1b. Armour/Earth Conductor: Concentric earth conductor as tensile-stress-resistant braided armour of combined copper-steel wires. Outer Sheath: Chlorinated rubbe type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Insulation Thickness
No. ×mm² 3x50/25KON + 3xST
mm 2.0
12
Thickness of Inner Thickness of Outer Sheath Sheath mm 3.0
Nominal Overall Diameter
Nominal Weight
mm 56
kg/km 4950
mm 5.0
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NTMTWOEU 0.6/1kV Mine Hoist Cables »» Applications These cables are used as suspended cable for intrinsically safe control of user-operated mine hoists (lifts) with telephonic connection in underground mines.
»» Standards VDE 0250 Part 813
»» Construction Stranded Tinned Copper Conductor 3GI3 Insulation Shielded Telephone-type Pilot Steel Support Element Textile Braid 5GM5 Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Insulation: EPR type 3GI3. Support Element: Central steel support element. Anti-torsion Braid: Textile braid. Outer Sheath: PCP rubber type 5GM5.
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 8x2.5ST+2x1FM(C) 8x2.5ST+10x (2x1FM)C 14x2.5ST+6x1FM(C) 18x2.5ST+6x1FM(C) 19x1.5(C)ST+6x (2x1FM)C
mm 21.7 34.0 27.0 38.0 35.1
mm 23.7 37.5 31.0 42.0 38.1
kg/km 800 1450 1200 1800 2145
www.caledonian-cables.co.uk www.addison-cables.com
13
Caledonian Mining Cables Cables for Underground Mining
NSHTOEU 0.6/1kV LHD Cables »» Applications These cables are used for frequently changing dynamic loads, such as reeling cables for scoops (LHDs) in underground mines, suitable for mono-spiral reels and cylindrical reels.
»» Standards VDE 0250 Part 814
Stranded Tinned Copper Conductor 3GI3 Insulation Steel Support Element
»» Construction
5GM5 Inner Sheath
Polyester Threads Braid Conductors: Flexible stranded tinned 5GM5 Outer Sheath copper conductor. Insulation: EPR type 3GI3. Support Element: Central steel support element. Inner Sheath: PCP type 5GM5. Anti-torsion Braid: Reinforced braid of polyester threads in a vulcanized bond between inner and outer sheath. Outer Sheath: PCP type 5GM5.
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 4x16(6 kN) 4x35(12 kN) 4x50(12 kN) 4x50(30 kN) 4x70 (20kN) 4x95 (50kN)
mm 27.5 37.5 43.0 42.0 47.0 53.0
mm 31.5 42.0 48.0 44.0 52.0 58.0
kg/km 1500 2920 3970 3660 5530 6500
14
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NSSHCGEOEU 0.6/1kV Coal Cutter Cable (High Tensile Stress) »» Applications These cables are used for the connection of mobile machines under extremely high mechanical loads, predominantly in mining situations, e.g. for coal-cutting machines, also can be operated via guide pulleys (cable cars) or used as a reeling cable (LHD), suitable for extreme bending loads, high tensile stress, and impact and crushing loads.
»» Standards VDE 0250 Part 812
»» Construction Stranded Tinned Copper Conductor Monitoring Conductor 3GI3 Rubber Insulation GM1b Rubber Inner Sheath Copper-Steel Wires Braid Pilot Cores 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor. Insulation: Heat resistant 3GI3 rubber based on EPR. Outer Conductor Layer: Easy strippable outer conductive layer. Pilot Cores: Copper and steel conductor capable of expansion and compression with 3GI3 EPR rubber insulation. Monitoring Conductor: Copper and steel conductor capable of expansion and compression covert with semi conductive rubber compound. Inner Sheath: Rubber type GM1b. Armour/Earth Conductor: Concentric earth conductor as tensile-stress-resistant braided armour of combined copper-steel wires. Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
www.caledonian-cables.co.uk www.addison-cables.com
15
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×16/16KON+2ST+UEL 3×25/16KON+2ST+UEL 3×35/16KON+2ST+UEL 3×50/25KON+2ST+UEL 3×70/35KON+2ST+UEL 3×95/50KON+2ST+UEL 3×35/16KON+3ST+3UEL 3×50/25KON+3ST+3UEL 3×70/35KON+3ST+3UEL 3×95/50KON+3ST+3UEL 3×120/70KON+3ST+3UEL 3×150/70KON+3ST+3UEL
mm 38.5 41.0 44.5 50.0 54.5 62.5 44.5 50.0 54.5 62.5 67.5 74.5
mm 41.5 44.5 48.0 54.0 58.5 66.5 48.0 54.0 58.5 66.5 72.0 79.0
kg/km 2430 3050 3620 4810 5890 7800 3860 5050 6000 8050 9380 11120
16
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NSSHCGEOEU 0.6/1kV Coal Cutter Cable (Low Tensile Stress) »» Applications These cables are used for the connection of mobile machines under extremely high mechanical loads, predominantly in mining situations, e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress.
»» Standards DIN VDE 0250 Part 812
»» Construction 3GI3 Rubber Insulation Stranded Tinned Copper Conductor Monitoring Conductor Outer Conductor Layer GM1b Rubber Inner Sheath Spiral Of Copper And Steel Wires Pilot Cores 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor. Insulation: Heat resistant 3GI3 rubber based on EPR. Outer Conductor Layer: Easy strippable outer conductive layer. Pilot Cores: Copper strand and steel braid conductor capable of expansion and compression with EPR rubber insulation. Monitoring Cores: Spiral of tinned copper wires above the pilot cores, covered with a semiconductive tape. Inner Sheath: Rubber type GM1b. Armour/Earth Conductor: Concentric earth conductor as spiral of copper and steel wires, fibreglas tape, embedded in the outer sheath which prevents sheath exchanging. Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
www.caledonian-cables.co.uk www.addison-cables.com
17
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×16/16KON+2ST+UEL 3×25/16KON+2ST+UEL 3×35/16KON+2ST+UEL 3×50/25KON+2ST+UEL 3×70/35KON+2ST+UEL 3×95/50KON+2ST+UEL 3×25/16KON+3×(1.5ST+UEL) 3×35/16KON+3×(1.5ST+UEL) 3×50/25KON+3×(1.5ST+UEL) 3×70/35KON+3×(1.5ST+UEL) 3×95/50KON+3×(1.5ST+UEL) 3×120/70KON+3×(1.5ST+UEL) 3×150/70KON+3×(1.5ST+UEL)
mm 35.0 38.0 41.0 47.0 52.0 58.0 38.0 41.0 45.0 48.0 52.0 58.0 62.0
mm 38.0 41.0 45.0 51.0 56.0 62.0 41.0 45.0 48.0 53.0 56.0 63.0 68.0
kg/km 2130 2790 3390 4340 5680 7180 2920 3630 4500 5850 7400 8300 9300
18
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
(N)SSHOEU 0.6/1kV Heavy Duty Flexible Cable »» Applications These cables are used for connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining and at quarries and building sites.
»» Standards Based on VDE 0250 Part 812
»» Construction Stranded Tinned Copper Conductor 3GI3 Rubber Insulation Earth Conductor GM1b Rubber Inner Sheath 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Insulation: Rubber type 3GI3. Pilot Cores (optional): Tinned copper conductor with EPR insulation. Earth Conductor: Spiral of tinned copper wires. Inner Sheath: Rubber type GM1b. Outer Sheath: Rubber type 5GM5.
»» Dimensions and Weight Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3x2.5+3x2.5/3E 3x6+3x6/3E 3x10+3x10/3E
mm 14.0 18.0 21.0
mm 17.0 21.0 25.0
kg/km 300 580 860
www.caledonian-cables.co.uk www.addison-cables.com
19
Caledonian Mining Cables Cables for Underground Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3x2.5+3x2.5/3E+3x1.5 3x6+3x6/3E+3x1.5 3x10+3x10/3E+3x2.5 3x25+3x16/3E+3x2.5 3x35+3x16/3E+3x2.5 3x50+3x25/3E+3x2.5 3x70+3x35/3E+3x2.5 3x95+3x50/3E+3x2.5 3x120+3x70/3E+3x2.5 3x150+3x70/3E+3x2.5
mm 17.0 18.0 21.0 28.0 30.0 36.0 41.0 47.0 52.0 58.0
mm 20.0 22.0 26.0 33.0 35.0 41.0 46.0 52.0 57.0 63.0
kg/km 450 660 950 1660 1970 2840 3700 4950 5650 6520
20
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NSSHOEU-O/J 0.6/1kV Heavy Duty Flexible Cable »» Applications These cables are designed for the connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining and industry, quarries and building sites.
»» Standards VDE 0250 Part 812
»» Construction Stranded Tinned Copper Conductor 3GI3 Rubber Insulation GM1b/5GM3 Rubber Inner Sheath 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Insulation: Heat resistant EPR type 3GI3. Inner Sheath: SR/SBR/PCP/CR type GM1b/5GM3. Outer Sheath: Chlorinated rubber PCP/CR type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
»» Dimensions and Weight NSSHOEU-O Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×16 1×25 1×35
mm 11.0 13.0 14.0
mm 13.0.5.0 16.0 17.0
kg/km 260 390 500
www.caledonian-cables.co.uk www.addison-cables.com
21
Caledonian Mining Cables Cables for Underground Mining
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×50 1×70 1×95 1×120 1×150 1×185 1×240 2×1.5 3×2.5
mm 16.0 18.0 20.0 23.0 24.0 28.0 32.0 11.0 13.0
mm 19.0 21.0 24.0 27.0 28.0 31.0 36.0 14.0 16.0
kg/km 680 900 1150 1440 1750 2300 3000 210 300
NSSHOEU-J Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×1.5 3×70/35 3×95/50 3×120/70 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 5×1.5 5×2.5 5×4 5×6 5×10 5×16 5×25 6×2.5 7×1.5 7×2.5 10×1.5 10×2.5 12×2.5 18×2.5
mm 12.0 46.0 54.0 59.0 13.0 15.0 17.0 18.0 22.0 28.0 33.0 36.0 42.0 13.0 16.0 18.0 20.0 24.0 29.0 35.0 13.0 16.0 18.0 19.0 21.0 22.0 28.0
mm 15.0 51.0 59.0 64.0 16.0 18.0 20.0 21.0 26.0 32.0 37.0 40.0 47.0 16.0 19.0 21.0 24.0 28.0 34.0 39.0 16.0 19.0 21.0 22.0 25.0 26.0 32.0
kg/km 240 4450 5870 7340 280 400 510 630 950 1430 2100 2650 3660 320 470 600 780 1130 1720 2470 300 470 600 570 790 860 1240
22
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable »» Applications These cables are designed for the connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining and industry, quarries and building sites.
»» Standards VDE 0250 Part 812
»» Construction Stranded Tinned Copper Conductor 3GI3 Rubber Insulation GM1b Rubber Inner Sheath Earth Conductor Control Cores 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Insulation: Heat resistant EPR type 3GI3. Earth Conductor: Distributed as spiral of tinned copper wires over core insulating coverings (coding .../3E) or located concentrically between the inner and outer sheaths (coding ...kon). Control Cores: Laid in the interstices, film wrap. Inner Sheath: Rubber type GM1b. Outer Sheath: Chlorinated rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
»» Dimensions and Weight Number of Cores×Nominal Cross Minimium Overall Diameter Maximum Overall Diameter Section No. ×mm² 3×2.5+3×2.5/3E
mm 15.0
mm 18.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 410
23
Caledonian Mining Cables Cables for Underground Mining
Number of Cores×Nominal Cross Minimium Overall Diameter Maximum Overall Diameter Section No. ×mm² 3×4+3×4/3E 3×6+3×6/3E 3×10+3×10/3E 3×16+3×16/3E 3×25+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×2.5+3×2.5/3E+3×1.5ST 3×4+3×4/3E+3×1.5ST 3×6+3×6/3E+3×1.5ST 3×10+3×10/3E+3×2.5ST 3×16+3×16/3E+3×2.5ST 3×25+3×16/3E+3×2.5ST 3×35+3×16/3E+3×2.5ST 3×50+3×25/3E+3×2.5ST 3×70+3×35/3E+3×2.5ST 3×95+3×50/3E+3×2.5ST 3×120+3×70/3E+3×2.5ST 3×150+3×70/3E+3×2.5ST 3×2.5/2.5KON 5×2.5/2.5KON 5×4/4KON 5×6/6KON 10×1.5/1.5KON 10×2.5/2.5KON
24
mm 19.0 18.0 22.0 28.0 29.0 40.0 44.0 52.0 56.0 62.0 18.0 19.0 20.0 24.0 28.0 30.0 34.0 41.0 44.0 52.0 51.0 59.0 14.0 18.0 20.0 20.0 20.0 26.0
mm 22.0 21.0 26.0 32.0 33.0 44.0 49.0 57.0 61.0 68.0 20.0 22.0 24.0 28.0 32.0 34.0 38.0 46.0 49.0 57.0 56.0 64.0 17.0 21.0 24.0 24.0 24.0 29.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 500 660 950 1350 1800 3300 4360 5740 6870 8140 500 550 810 1150 1470 1960 2590 3560 4470 5850 6800 8100 380 560 710 910 800 1100
Caledonian Mining Cables Cables for Underground Mining
NSSHOEU/NTSWOEU Submersible Cable Up To 6kv »» Applications These cables are used for the connection of electrical operating equipment in industrial water, notably for submersible pumps. 3-core cables without earth cores are used where the ascending pipe serves as earth conductor.
»» Standards VDE 0250 Part 812 VDE 0250 Part 813
»» Construction Stranded Tinned Copper Conductor EPR Insulation GM1b Rubber Inner Sheath 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Insulation: Heat resistant EPR. Inner Sheath: Rubber type GM1b. Outer Sheath: Chlorinated rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant (for 0.6/1kV). Chlorinated rubber type 5GM3, oil resistant and flame retardant (for 1.8/3kV, 3.6/6kV).
»» Dimensions and Weight NSSHOEU 0.6/1kV Number of Cores×Nominal Cross Section
Nominal Overall Diameter
Nominal Weight
No. ×mm² 3×4
mm 17.0
kg/km 400
www.caledonian-cables.co.uk www.addison-cables.com
25
Caledonian Mining Cables Cables for Underground Mining Number of Cores×Nominal Cross Section
Nominal Overall Diameter
Nominal Weight
No. ×mm² 3×10 3×16 3×25 3×35 3×50 3×70 3×95 4×25 4×35 4×50 3×70/35
mm 22.0 26.0 31.0 35.0 41.0 45.0 52.0 35.0 38.0 45.0 49.0
kg/km 720 1050 1500 2050 2820 3540 4750 2010 2530 3500 4190
Number of Cores×Nominal Cross Section
Nominal Overall Diameter
Nominal Weight
No. ×mm² 3×25 3×35 3×50 3×70 3×95
mm 35.0 39.0 43.0 48.0 53.0
kg/km 1840 2410 3040 3920 4950
Number of Cores×Nominal Cross Section
Nominal Overall Diameter
Nominal Weight
No. ×mm² 3×25 3×35 3×50 3×70 3×95
mm 45.0 47.0 51.0 56.0 60.0
kg/km 2690 3180 3860 4870 5870
NTSWOEU 1.8/3kV
NTSWOEU 3.6/6kV
26
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NTSCGERLWOEU 3.6/6kV Flexible Submersible Cable »» Applications These cables are used for permanent operation in water where the cable is required to have additional mechanical protection.
»» Standards VDE 0250 Part 813
»» Construction Stranded Copper Conductor 3GI3 Rubber Insulation Optional Pilot Cores Earth Conductor Synthetic Butyl Rubber Inner Sheath Galvanised Steel Wire Braid 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Special rubber compound, conductive. Insulation: Rubber type 3GI3. Outer Conductor Layer: Special rubber, conductive, easy strippable. Pilot Cores (optional): Copper conductor with EPR insulation. Earth Conductor: Spiral of tinned annealed copper wires. Inner Sheath: Waterproof synthetic butyl rubber. Armouring: Braid of galvanised steel strands. Outer Sheath: Rubber type 5GM5.
www.caledonian-cables.co.uk www.addison-cables.com
27
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight Number of Cores×Nominal Cross Section No. ×mm² 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E
28
Minimium Overall Diameter Maximum Overall Diameter mm 55.0 59.0 64.0 68.0 75.0
mm 60.0 67.0 70.0 75.0 80.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 4600 5600 6700 7900 9980
Caledonian Mining Cables Cables for Underground Mining
NTSKCGERLOEU Medium Voltage Coal Cutter Cable »» Applications These cables are used for the connection of mobile electrical equipment in underground mines, e.g. for coal-cutting machines, especially for the use in bretby chains with extreme bending loads under low tensile stress.
»» Standards VDE 0250 Part 813
»» Construction 3GI3 Rubber Insulation Stranded Tinned Copper Conductor Earth Conductor Outer Conductor Layer Semi Conductive+5GM5 Rubber Inner Sheath Spiral Of Copper And Steel Wires Pilot Cores 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor. Insulation: Heat resistant 3GI3 rubber based on EPR. Outer Conductor Layer (for 3.6/6kV): Easy strippable outer conductive layer. Pilot Cores: Copper/steel conductor capable of expansion and compression with EPR rubber insulation. Earth Conductor: Spiral of tinned copper wires and a conductive tape. Inner Sheath: 2 layer design, semi conductive rubber + Rubber type 5GM5. Armour: Spiral of steel wires, embedded in the outer sheath, fiberglas tape which prevents sheath exchanging. Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
www.caledonian-cables.co.uk www.addison-cables.com
29
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight 1.8/3kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×35+3×(1.5ST+25/3)+UEL 3×50+3×(1.5ST+25/3)+UEL 3×70+3×(1.5ST+35/3)+UEL 3×95+3×(1.5ST+50/3)+UEL 3×120+3×(1.5ST+70/3)+UEL
mm 44.0 50.0 52.0 58.0 64.0
mm 49.0 55.0 56.0 62.0 70.0
kg/km 3900 5100 6200 7500 9350
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×35+3×(1.5ST+25/3)+UEL 3×50+3×(1.5ST+25/3)+UEL 3×70+3×(1.5ST+35/3)+UEL 3×95+3×(1.5ST+50/3)+UEL 3×120+3×(1.5ST+70/3)+UEL
mm 49.0 56.0 57.0 62.0 67.0
mm 54.0 61.0 62.0 66.0 71.0
kg/km 5800 6100 6700 8000 10200
3.6/6kV
30
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
NTSCGECWOEU Medium Voltage Coal Cutter Cable »» Applications These cables are used for the connection of mobile electrical equipment in underground mines, e.g. for coal-cutting machines, especially for the use in bretby chains with extreme bending loads under low tensile stress.
»» Standards VDE 0250 Part 813
»» Construction System1 System2 Earth Conductor Center Bundle Semi Conductive+5GM5 Rubber Inner Sheath Spiral Of Steel Wires 5GM5 Rubber Outer Sheath
System1 (1.8/3kV or 3.6/6kV): Flexible stranded tinned copper conductor with heat resistant 3GI3 rubber based on EPR, easy strippable outer conductive layer. System2 (0.6/1kV): Flexible stranded tinned copper conductor with heat resistant 3GI3 rubber based on EPR. Earth Conductor: Spiral of tinned copper. Center Bundle: Control and pilot cores with copper/steel conductors capable of expansion and compression, EPR insulation, optional with fiber optics, covered with tinned copper wires semi conductive rubber sheath. Inner Sheath: 2 layer design, semi conductive rubber + Rubber type 5GM5. Armour: Spiral of steel wires, embedded in the outer sheath, fiberglas tape which prevents sheath exchanging. Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.
www.caledonian-cables.co.uk www.addison-cables.com
31
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight 1.8/3kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×50+3×(35+35/3)+2×(2×0.75ST)+2×0.75UEL 3×70+3×(50+50/3)+2×(2×0.75ST)+2×0.75UEL 3×95+3×(70+70/3)+2×(2×0.75ST)+2×0.75UEL
mm 62.0 64.0 74.0
mm 66.0 68.0 78.0
kg/km 7210 8200 10300
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×35+3×(35+35/3)+2×(2×0.75ST)+2×0.75UEL 3×50+3×(50+50/3)+2×(2×0.75ST)+2×0.75UEL 3×70+3×(70+70/3)+2×(2×0.75ST)+2×0.75UEL 3×95+3×(95+95/3)+2×(2×0.75ST)+2×0.75UEL
mm 66.0 69.0 76.0 85.0
mm 72.0 75.0 81.0 90.0
kg/km 7600 9200 11150 13300
3.6/6kV
32
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
(N)TSCGECWOEU Medium Voltage Trailing Cable »» Applications These cables are used for the connection of electrical equipment, in mines and underground excavations with hazardous environments under particularly high mechanical loads, e.g. high-voltage transformers on power lines in underground mining and tunnelling.
»» Standards Based on VDE 0250 Part 813
»» Construction Stranded Copper Conductor 3GI3 Rubber Insulation Optional Pilot Cores Earth Conductor GM1b Inner Sheath Monitoring Conductor 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Special rubber compound, conductive. Insulation: Rubber type 3GI3. Outer Conductor Layer: Special rubber compound, conductive, easy strippable. Pilot Cores (optional): Tinned copper conductor with EPR insulation. Earth Conductor: Spiral of tinned copper wires. Inner Sheath: Rubber type GM1b. Monitoring Shield/Armour: Braided armour of combined copper-steel wires; or wrap of copper and steel wires, copper tape in opposite direction, reinforcing tape. Outer Sheath: Rubber type 5GM5.
www.caledonian-cables.co.uk www.addison-cables.com
33
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight 6/10kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×16/3E+3×2.5ST+6UEL 3×35+3×16/3E+3×2.5ST+6UEL 3×50+3×25/3E+3×2.5ST+6UEL 3×95+3×50/3E+3×2.5ST+6UEL 3×120+3×70/3E+6UEL 3×150+3×70/3E+6UEL
mm 48.0 51.0 56.0 66.0 70.0 73.0
mm 52.0 55.0 60.0 71.0 75.0 78.0
kg/km 3500 3750 4720 7260 9700 9950
12/20 (24) kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3E+6UEL 3×95+3×50/3E+6UEL 3×120+3×70/3E+6UEL
mm 62.0 74.0 80.0
mm 67.0 78.0 85.0
kg/km 5800 11000 13000
34
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
(N)TSCGEWOEU Medium Voltage Trailing Cable With Anti-Torsion Braid »» Applications These cables are used for the connection of electrical equipment, in mines and underground excavations with hazardous environments under particularly high mechanical loads, e.g. high-voltage transformers on power lines in underground mining and tunnelling.
»» Standards
Stranded Copper Conductor
Based on VDE 0250 Part 813
3GI3 Rubber Insulation Earth Conductor GM1b Inner Sheath
»» Construction
Polyester Anti-torsion Braid
Conductors: Flexible stranded copper 5GM5 Rubber Outer Sheath conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Special rubber compound, conductive. Insulation: Rubber type 3GI3. Outer Conductor Layer: Special rubber compound, conductive, easy strippable. Earth Conductor: Spiral of tinned copper wires. Inner Sheath: Rubber type GM1b. Reinforcement: Polyester anti-torsion braid between the jackets embedded. Outer Sheath: Rubber type 5GM5.
»» Dimensions and Weight 8.7/15kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×150+3×70/3E
mm 73.0
mm 78.0
kg/km 10150
www.caledonian-cables.co.uk www.addison-cables.com
35
Caledonian Mining Cables Cables for Underground Mining
NSGAFOEU/NSHXAFOE Medium Voltage Single Core Cables »» Applications These cables are designed for fixed installation in track-bound vehicles and buses, in pipes and closed installation ducts, as well as for the connection of mobile parts. 3 kV-rated cables can be used in low-voltage switch boards to ensure inherently short-circuit and earth-fault proof connections.
»» Standards DIN VDE 0250 Part 602 (for NSGAFOEU/NSGAFCMOEU) DIN VDE 0250 Part 606 (for halogen free version NSHXAFOE/NSHXAFCMOE)
»» Construction Stranded Tinned Copper Conductor 3GI3/3GJ3 Rubber Insulation 5GM3/HM3 Rubber Outer Sheath
Conductors: Stranded tinned copper conductor, class 5 according to DIN VDE 0295/IEC 60228. Inner Conductor Layer (for 6kV): Semi-conducting layer. Insulation: EPR compound type 3GI3/3GJ3. Optional Screen (for NSGAFCMOEU/NSHXAFCMOE): Tinned copper wires. Outer Sheath: Chlorinated rubber type 5GM3, oil resistant and flame retardant (for NSGAFOEU/ NSGAFCMOEU). Halogen-free polymer compound HM3, oil-resistant, flame retardant, low smoke (for NSHXAFOE/NSHXAFOE).
»» Dimensions and Weight NSGAFOEU/ NSHXAFOE 1.8/3kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×1.5
mm 5.7
mm 7.0
kg/km 50
36
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×2.5 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400
mm 6.0 6.8 7.3 8.7 10.0 12.4 13.4 14.9 16.6 19.3 20.8 23.0 25.2 28.1 30.8 40.0
mm 7.5 9.0 9.5 11.0 13.0 15.0 16.5 18.0 20.5 24.0 26.0 28.0 31.0 34.5 38.0 34.6
kg/km 60 80 100 160 230 340 430 580 780 1030 1270 1570 1900 2500 3000 4000
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×1.5 1×2.5 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185
mm 8.3 8.6 9.4 9.9 10.9 12.6 14.5 15.6 17.1 18.8 21.3 23.2 25.0 26.8
mm 9.5 10.5 12.0 13.0 14.5 15.5 17.5 19.0 21.0 23.0 26.5 28.5 30.5 33.0
kg/km 135 150 170 200 250 350 480 600 760 960 1240 1530 1790 2130
NSGAFOEU/NSHXAFOE 3.6/6kV
NSGAFCMOEU/NSHXAFCMOE 3.6/6kV Number of Cores×Nominal Cross Section
Nominal Overall Diameter
Nominal Weight
No. ×mm² 1×185
mm 38.5
kg/km 3060
www.caledonian-cables.co.uk www.addison-cables.com
37
Caledonian Mining Cables Cables for Underground Mining
N3GHSSYCY Medium Voltage Cable »» Applications These cables are used for the connection of mobile operating equipment, in mines and underground excavations with hazardous environments, in stationary operation, e.g. high-voltage transformers in mining and tunnelling.
»» Standards VDE 0250 Part 605
»» Construction Monitoring Conductor PVC Intermediate Sheath Galvanized Steel Wires Braid 5GM5 Rubber Outer Sheath
Stranded Copper Conductor Pilot Cores 3GI3 Rubber Insulation Earth Conductor PVC Inner Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Insulation: EPR compound type 3GI3. Electrical Field Control: Inner and outer semiconductive layer of semiconductive rubber, for 6 kV outer semiconductive layer only. Pilot Cores: Stranded copper conductor with EPR insulation. Earth Conductor: Spiral of copper wires over the outer semi-conductive layer of the cores. Inner Sheath: PVC compound type YM5. Monitoring Conductor: Conductive tape serving and overall concentric Cu wire spinning. Intermediate Sheath: PVC compound type YM5. Armour: Braid of galvanized steel wires. Outer Sheath: PVC compound type YM5.
38
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Underground Mining
»» Dimensions and Weight 3.6/6kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×16/3E+3×2.5ST+UEL 3×35+3×16/3E+3×2.5ST+UEL 3×50+3×25/3E+3×2.5ST+UEL 3×70+3×35/3E+3×2.5ST+UEL 3×95+3×50/3E+3×2.5ST+UEL
mm 49.0 52.0 55.0 59.0 63.0
mm 53.0 56.0 59.0 63.0 67.0
kg/km 4190 4800 5600 6650 7940
Minimium Overall Diameter mm 55.0. 58.0 61.0 65.0 68.0
Maximum Overall Diameter mm 58.0 61.0 65.0 69.0 73.0
Minimium Overall Diameter mm 58.0 61.0 64.7 67.9 72.4
Maximum Overall Diameter mm 62.0 65.0 68.7 71.9 76.4
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×16/3E+3×2.5ST+UEL 3×35+3×16/3E+3×2.5ST+UEL 3×50+3×25/3E+3×2.5ST+UEL 3×70+3×35/3E+3×2.5ST+UEL 3×95+3×50/3E+3×2.5ST+UEL
mm 62.3 65.3 69.0 72.2 76.8
mm 66.3 69.3 73.0 76.2 80.8
kg/km 8790 9930 11360 13100 14750
6/10kV Number of Cores×Nominal Cross Section No. ×mm² 3×25+3×16/3E+3×2.5ST+UEL 3×35+3×16/3E+3×2.5ST+UEL 3×50+3×25/3E+3×2.5ST+UEL 3×70+3×35/3E+3×2.5ST+UEL 3×95+3×50/3E+3×2.5ST+UEL
Nominal Weight kg/km 5300 5910 6790 7860 9180
8.7/15kV Number of Cores×Nominal Cross Section No. ×mm² 3×25+3×16/3E+3×2.5ST+UEL 3×35+3×16/3E+3×2.5ST+UEL 3×50+3×25/3E+3×2.5ST+UEL 3×70+3×35/3E+3×2.5ST+UEL 3×95+3×50/3E+3×2.5ST+UEL
Nominal Weight kg/km 6810 7850 9130 10750 12290
12/20kV
www.caledonian-cables.co.uk www.addison-cables.com
39
Caledonian Mining Cables Cables for Open-cast Mining
(N)SHOEU 0.6/1kV Flexible cable »» Applications These cables are designed for use in open cast mining factories for laying of excavators and conveyor belts with permanent movements between parts of the equipment. These cables are used where the ascending pipe serves as earth conductor, for instance for submersible pumps.
»» Standards VDE 0250 Part 812
»» Construction Stranded Copper Conductor EPR Insulation EPR Inner Sheath 5GM5 Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295/IEC 60228. Insulation: EPR. Earth Conductor (for –J type): Incorporated as a fourth core or split into three in the outer interstices. Inner Sheath: EPR. Outer Sheath: CM type 5GM5.
»» Dimensions and Weight (N)SHOEU-J Number of Cores×Nominal Cross Section
Insulation Thickness
No. ×mm² 3×1.0
mm 0.60
40
Thickness of Thickness of Inner Sheath Outer Sheath mm 0.8
mm 1.2
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
mm 9.2
mm 9.6
kg/km 160
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
Number of Cores×Nominal Cross Section
Insulation Thickness
No. ×mm² 3×1.5 3×2.5 3×4 3×6 3×10 3x50+3x25/3 3x70+3x35/3 3x95+3x50/3 3x120+3x70/3 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120
mm 0.60 0.70 0.80 0.80 1.00 1.10 1.10 1.20 1.20 0.60 0.70 0.80 0.80 1.00 1.00 1.00 1.00 1.10 1.10 1.20 1.20
Thickness of Thickness of Inner Sheath Outer Sheath mm 0.8 0.8 0.9 1.0 1.0 1.4 1.4 1.7 2.0 0.8 0.9 0.9 1.0 1.0 1.2 1.3 1.3 1.5 1.5 1.7 2.0
mm 1.2 1.2 1.3 1.4 1.4 2.5 2.5 2.8 3.0 1.2 1.4 1.4 1.4 1.6 1.8 2.2 2.3 2.6 2.6 2.8 3.3
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
mm 10.4 11.3 12.5 13.9 16.8 31.5 36.2 42.0 46.0 10.7 11.7 13.7 15.2 19.0 22.0 26.5 30.0 34.5 39.5 45.0 51.0
mm 12.0 12.9 14.1 15.5 18.8 34.5 39.2 45.0 49.0 13.0 13.7 15.7 17.2 21.0 24.0 29.5 33.0 38.5 43.5 49.0 55.0
kg/km 180 240 295 370 570 2500 3400 4475 5400 210 260 350 485 690 1090 1600 2090 2700 3620 4710 6020
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
mm 12.0 13.0 14.8 17.0 20.0 23.8 29.5 9.8 13.0 14.0 15.5
mm 14.0 14.8 17.0 19.0 23.0 26.8 32.5 11.8 14.6 15.6 17.5
kg/km 240 305 440 580 870 1280 1950 155 295 320 390
(N)SHOEU-O Number of Cores×Nominal Cross Section
Insulation Thickness
No. ×mm² 5×1.5 5×2.5 5×4 5×6 5×10 5×16 5×25 2×1.5 7×1.5 8×1.5 10×1.5
mm 0.60 0.70 0.80 0.80 1.00 1.00 1.00 0.60 0.60 0.60 0.60
Thickness of Thickness of Inner Sheath Outer Sheath mm 0.8 0.9 0.9 1.0 1.0 1.2 1.3 0.8 0.9 0.9 1.0
mm 1.2 1.3 1.4 1.6 1.6 1.8 2.3 1.2 1.4 1.4 1.6
www.caledonian-cables.co.uk www.addison-cables.com
41
Caledonian Mining Cables Cables for Open-cast Mining
Number of Cores×Nominal Cross Section
Insulation Thickness
No. ×mm² 12×1.5 2×2.5 4×2.5 7×2.5 8×2.5 10×2.5 12×2.5 18×2.5 24×2.5 2×4 12×4 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185
mm 0.60 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.80 0.80 1.00 1.00 1.00 1.10 1.10 1.20 1.20 1.30 1.40 1.50 1.80 0.70 0.80 0.80 1.00 1.00 1.00 1.10 1.10 1.10 1.20 1.20 1.30 1.40
42
Thickness of Thickness of Inner Sheath Outer Sheath mm 1.0 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.2 0.9 1.2 0.8 0.9 1.0 1.0 1.0 1.2 1.3 1.5 1.5 1.7 1.8 1.7 2.2
mm 1.6 1.2 1.4 1.4 1.4 1.6 1.6 1.6 1.8 1.2 1.8 1.4 1.7 1.8 2.0 2.2 2.3 2.4 2.5 2.6 2.8 3.3 1.2 1.3 1.4 1.4 1.6 2.0 2.2 2.6 2.6 2.8 3.0 2.8 3.4
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
mm 16.5 10.8 11.7 15.0 16.0 18.0 18.5 21.5 25.5 12.0 25.0 9.6 11.2 12.6 14.6 16.6 18.9 20.8 23.0 24.9 28.2 31.8 11.3 12.5 13.9 16.8 19.0 23.5 27.5 31.5 36.0 41.0 45.0 49.0 55.0
mm 18.5 12.8 13.7 17.0 19.0 20.5 21.5 24.5 28.5 13.6 28.0 11.2 13.2 14.6 16.6 18.6 20.9 22.8 25.0 27.9 31.2 34.8 12.9 14.1 15.5 18.8 22.0 26.5 30.5 35.5 40.0 45.0 49.0 53.0 59.0
kg/km 445 195 290 410 430 520 580 835 895 250 990 215 325 430 610 825 1070 1300 1610 2000 2500 3200 240 295 370 570 770 1200 1570 2200 2910 3780 4700 5650 7050
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
2YSLGCGOEU Signal & Control Cable »» Applications These control, signalling and bus cables are used for electric and electronic equipment, such as for measured value and process data processing and automation units in open-cast mining applications, suitable for laying alongside conveyor belts and on material handling equipment.
»» Standards VDE 0250 Part 812
»» Construction Stranded Copper Conductor 2YI1 Insulation EM2 Inner Sheath Tinned Copper Wire Braid EM2 Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Insulation: PE type 2YI1. Cable Element: Cores are laid-up in pairs in layers with a continuous serving of non-hygroscopic material over the conductor assembly Inner Sheath: CM type EM2. Screen: Tinned copper wire braid. Outer Sheath: CM type EM2.
»» Dimensions and Weight Number of Cores×Nominal Cross Section No. ×mm² 2×2×1 5×2×1 10×2×1 20×2×1
Minimium Overall Diameter Maximum Overall Diameter mm 11.0 16.0 20.0 25.0
mm 13.0 19.0 23.0 29.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 245 440 700 1040 43
Caledonian Mining Cables Cables for Open-cast Mining
(N)TSCGEWOEU Medium Voltage Reeling Cable Without Fibre Optics »» Applications These cables are used for connection of large mobile equipment such as excavators and spreaders, loading bridges, gantry cranes, construction machines, etc., under very high mechanical loads, in dry or damp environment, also in environments with high explosion risk.
»» Standards
3GI3 Rubber Insulation Stranded Copper Conductor
Based on VDE 0250 Part 813
GM1b/5GM3 Rubber Inner Sheath Polyester Braid
»» Construction
Earth Conductor 5GM3/5GM5 Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: EPR type 3GI3. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Incorporated as a fourth core or distributed within the outer interstices. Inner Sheath: Rubber type GM1b/5GM3. Reinforcement: Polyester anti-torsion braid. Outer Sheath: Chlorinated rubber type 5GM3/5GM5, flame retardant and oil resistant.
»» Dimensions and Weight 3.6/6kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3
mm 39.0 42.0 45.0 50.0 54.0
mm 42.0 45.0 48.0 54.0 58.0
kg/km 2410 2995 3645 4760 5580
44
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3
mm 58.0 63.0 67.0
mm 62.0 67.0 72.0
kg/km 6690 7990 9330
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3
mm 40.0 43.0 46.0 51.0 55.0 59.0 64.0 69.0
mm 43.0 46.0 49.0 55.0 59.0 63.0 68.0 74.0
kg/km 2450 3035 3690 4800 5620 6740 8040 9380
Minimium Overall Diameter mm 42.1 43.8 44.9 44.9 49.5 49.5 53.1 53.1 57.3 63.0 66.6 70.5 78.0 84.9
Maximum Overall Diameter mm 45.1 46.8 47.9 47.9 53.5 53.5 57.1 57.1 61.3 67.0 70.6 74.5 82.0 89.9
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3
mm 46.0 49.0
mm 49.0 52.0
kg/km 3050 3490
6/10 kV
8.7/15 kV Number of Cores×Nominal Cross Section No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
Nominal Weight kg/km 2707 3062 3198 3382 4083 4267 5028 5303 6216 7673 8852 10351 13125 16020
12/20 kV
www.caledonian-cables.co.uk www.addison-cables.com
45
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3
mm 53.0 57.0 61.0 67.0 70.0 76.0
mm 57.0 61.0 65.0 71.0 74.0 80.0
kg/km 4340 5320 6360 7810 8900 10700
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 49.9 49.9 52.7 52.7 56.4 56.4 61.5 61.5 65.8 69.9 75.0 78.9 86.2 91.8
mm 53.9 53.9 56.7 56.7 60.4 60.4 65.5 65.5 69.8 73.9 79.0 82.9 91.2 96.8
kg/km 3542 3726 4075 4258 4872 5054 6083 6356 7303 8652 10139 11705 14670 17332
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3
mm 55.0 58.0 63.0 66.0 71.0 76.0 80.0 86.0
mm 59.0 62.0 67.0 70.0 75.0 80.0 84.0 90.0
kg/km 3960 4550 5510 6560 7850 9410 10690 12550
14/25 kV
18/30kV
46
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
(N)TSCGEWOEU Medium Voltage Reeling Cable With Fiber Optics »» Applications These cables are used for connection of large mobile equipment such as excavators and spreaders, gantry cranes, etc., under very high mechanical loads, suitable for motorised reeling on monospiral or level-wind reelers.
»» Standards Based on VDE 0250 Part 813
»» Construction 3GI3 Rubber Insulation Stranded Copper Conductor Fibre Optic Element GM1b/5GM3 Rubber Inner Sheath Polyester Braid Earth Conductor 5GM3/5GM5 Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: EPR type 3GI3. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Split into two in the outer interstices. Inner Sheath: Rubber type GM1b/5GM3. Fiber Optics: 12 FO 50/125 or 62.5/125 or E9/125μm within protection sheath. Reinforcement: Polyester anti-torsion braid. Outer Sheath: Rubber type 5GM3/5GM5, flame retardant and oil resistant.
www.caledonian-cables.co.uk www.addison-cables.com
47
Caledonian Mining Cables Cables for Open-cast Mining
»» Dimensions and Weight 3.6/6 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+12×LWL 3×35+2×25/2+12×LWL 3×50+2×25/2+12×LWL 3×70+2×35/2+12×LWL 3×95+2×50/2+12×LWL 3×120+2×70/2+12×LWL 3×150+2×70/2+12×LWL 3×185+2×95/2+12×LWL
mm 39.0 42.0 45.0 50.0 54.0 58.0 63.0 67.0
mm 42.0 45.0 48.0 54.0 58.0 62.0 67.0 72.0
kg/km 2410 2995 3645 4760 5580 6690 7990 9330
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+12×LWL 3×35+2×25/2+12×LWL 3×50+2×25/2+12×LWL 3×70+2×35/2+12×LWL 3×95+2×50/2+12×LWL 3×120+2×70/2+12×LWL 3×150+2×70/2+12×LWL 3×185+2×95/2+12×LWL
mm 40.0 43.0 46.0 51.0 55.0 59.0 64.0 68.0
mm 43.0 46.0 49.0 55.0 59.0 63.0 68.0 72.0
kg/km 2450 3035 3690 4800 5620 6740 8040 9380
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+12×LWL 3×35+2×25/2+12×LWL 3×50+2×25/2+12×LWL 3×70+2×35/2+12×LWL 3×95+2×50/2+12×LWL 3×120+2×70/2+12×LWL 3×150+2×70/2+12×LWL 3×185+2×95/2+12×LWL
mm 46.0 49.0 53.0 57.0 61.0 67.0 70.0 76.0
mm 49.0 52.0 57.0 61.0 65.0 71.0 74.0 80.0
kg/km 3050 3490 4340 5320 6360 7810 8900 10700
6/10 kV
12/20 kV
48
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining 18/30 kV Number of Cores×Nominal Cross Section No. ×mm² 3×25+2×25/2+12×LWL 3×35+2×25/2+12×LWL 3×50+2×25/2+12×LWL 3×70+2×35/2+12×LWL 3×95+2×50/2+12×LWL 3×120+2×70/2+12×LWL 3×185+2×95/2+12×LWL
Minimium Overall Diameter mm 55.0 58.0 63.0 66.0 71.0 76.0 86.0
Maximum Overall Diameter mm 59.0 62.0 67.0 70.0 75.0 80.0 90.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 3960 4550 5510 6560 7850 10690 12550
49
Caledonian Mining Cables Cables for Open-cast Mining
(N)TSCGEWOEU Medium Voltage Fixed Installation Cable Without Fibre Optics »» Applications These cables are used for laying alongside the conveyor belts (also for shiftable units) and on material handling equipment (even with continuous movement such as in cable booms or as connection between upper and lower car) and for connection of submersible pump units.
»» Standards Based on VDE 0250 Part 813
»» Construction Stranded Copper Conductor Earth Conductor EPR Rubber Insulation EPR Rubber Inner Sheath CM Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: EPR. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Split into three in the outer interstices. Inner Sheath: EPR. Outer Sheath: CM.
50
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
»» Dimensions and Weight 3.6/6 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 36.7 40.6 40.5 42.3 43.8 43.8 47.0 49.7 52.2 55.9 61.0 64.0 72.1 77.3
mm 39.7 43.6 43.5 45.3 46.8 46.8 50.0 53.7 56.2 59.9 65.0 68.0 76.1 81.3
kg/km 2320 2860 2860 3220 3500 3650 4360 5010 5550 6690 8030 9320 11960 14260
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 39.0 41.4 41.8 43.6 45.1 45.1 48.3 48.3 53.5 57.2 62.3 65.3 73.4 78.6
mm 42.0 44.4 44.8 46.6 48.1 48.1 51.3 51.3 57.5 61.2 66.3 69.3 77.4 82.6
kg/km 2520 2930 2980 3350 3640 3780 4500 4730 5710 6860 8210 9510 12170 14500
6/10 kV
www.caledonian-cables.co.uk www.addison-cables.com
51
Caledonian Mining Cables Cables for Open-cast Mining 8.7/15 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 42.5 44.2 45.3 45.3 49.4 49.4 52.7 52.7 57.0 62.1 65.7 68.7 76.8 82.0
mm 45.5 47.2 48.3 48.3 53.4 53.4 56.7 56.7 61.0 66.1 69.7 72.7 80.8 86.0
kg/km 2850 3210 3340 3480 4180 4320 5090 5310 6160 7550 8710 10020 12750 15110
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 45.5 45.5 48.3 48.3 52.5 52.5 55.7 55.7 61.4 65.1 68.7 73.2 79.8 86.3
mm 48.5 48.5 51.3 51.3 56.5 56.5 59.7 59.7 65.4 69.1 72.7 77.2 83.8 91.3
kg/km 3150 3300 3660 3800 4540 4680 5460 5690 6770 7980 9170 10780 13280 16070
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3
mm 50.3
mm 54.3
kg/km 3750
12/20 kV
14/25 kV
52
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 50.3 53.1 53.1 56.3 56.3 61.0 61.0 65.3 69.0 74.0 77.0 85.0 90.2
mm 54.3 57.1 57.1 60.3 60.3 65.0 65.0 69.3 73.0 78.0 81.0 90.0 95.2
kg/km 3900 4290 4430 5020 5160 6190 6410 7340 8580 10050 11430 14400 16860
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×25+3×50/3 3×35+3×25/3 3×35+3×50/3 3×50+3×25/3 3×50+3×50/3 3×70+3×35/3 3×70+3×50/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×240+3×120/3 3×300+3×150/3
mm 53.7 53.7 56.6 56.6 61.2 61.2 64.4 64.4 68.7 73.8 77.5 80.5 88.5 94.7
mm 57.7 57.7 60.6 60.6 65.2 65.2 68.4 68.4 72.7 77.8 81.5 84.5 93.5 99.7
kg/km 4160 4300 4730 4870 5700 5840 6680 6900 7860 9390 10660 12060 15090 17820
18/30kV
www.caledonian-cables.co.uk www.addison-cables.com
53
Caledonian Mining Cables Cables for Open-cast Mining
(N)TSCGEWOEU Medium Voltage Fixed Installation Cable With Fiber Optics »» Applications These cables are used for For laying alongside the conveyor belts (also for shiftable units) and on material handling equipment (even with continuous movement such as in cable booms or as connection between upper and lower car) and for connection of submersible pump units.
»» Standards Based on VDE 0250 Part 813
»» Construction Stranded Copper Conductor Fibre Optic Element EPR Insulation EPR Inner Sheath Earth Conductor CM Rubber Outer Sheath
Conductors: Flexible stranded copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: EPR. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Split into two in the outer interstices. Fiber Optics: FO 50/125 or 62.5/125 or E9/125μm within protection sheath. Inner Sheath: EPR. Outer Sheath: CM.
54
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
»» Dimensions and Weight 3.6/6 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL) 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 40.1 42.4 42.3 44.0 43.8 46.1 47.0 52.0 52.2 49.6 48.4 51.3 58.0 63.2
mm 43.1 45.4 45.3 47.0 46.8 49.1 50.0 56.0 56.2 50.9 52.3 55.3 62.0 67.2
kg/km 2650 3060 3060 3410 3490 3640 4350 5280 5550 7040 8000 9310 11940 14230
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL) 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 41.4 43.1 43.6 44.7 45.1 46.8 48.3 52.7 53.5 57.2 62.3 65.3 73.4 78.6
mm 44.4 46.1 46.6 47.7 48.1 49.8 51.3 56.7 57.5 61.2 66.3 69.3 77.4 82.6
kg/km 2770 3120 3190 3470 3620 4010 4500 5360 5710 6830 8180 9500 12160 14460
6/10 kV
www.caledonian-cables.co.uk www.addison-cables.com
55
Caledonian Mining Cables Cables for Open-cast Mining 8.7/15 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL) 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 44.2 45.4 45.3 47.0 49.4 51.2 52.7 55.0 57.0 62.1 65.7 68.7 76.8 82.0
mm 47.2 48.4 48.3 50.0 53.4 55.2 56.7 59.0 61.0 66.1 69.7 72.7 80.8 86.0
kg/km 3050 3350 3320 3710 4160 4590 5080 5640 6160 7520 8670 10010 12730 15080
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL) 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 45.5 47.2 48.3 51.0 52.5 52.5 55.7 58.0 61.4 65.1 68.7 73.2 79.8 86.3
mm 48.5 50.2 51.3 55.0 56.5 56.5 59.7 62.0 65.4 69.1 72.7 77.2 83.8 91.3
kg/km 3140 3530 3640 4240 4530 4690 5460 6040 6770 7950 9130 10770 13260 16040
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL)
mm 50.3 50.3
mm 54.3 54.3
kg/km 3740 3900
12/20 kV
14/25 kV
56
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 53.1 53.1 56.3 56.3 61.0 61.0 65.3 69.0 74.0 77.0 85.0 90.2
mm 57.1 57.1 60.3 60.3 65.0 65.0 69.3 73.0 78.0 81.0 90.0 95.2
kg/km 4270 4440 5000 5160 6190 6390 7340 8550 10020 11410 14380 16820
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×(6LWL) 3×25+2×50/2+1×(6LWL) 3×35+2×25/2+1×(6LWL) 3×35+2×50/2+1×(6LWL) 3×50+2×25/2+1×(6LWL) 3×50+2×50/2+1×(6LWL) 3×70+2×35/2+1×(6LWL) 3×70+2×50/2+1×(6LWL) 3×95+2×50/2+1×(6LWL) 3×120+2×70/2+1×(6LWL) 3×150+2×70/2+1×(6LWL) 3×185+2×95/2+1×(6LWL) 3×240+2×120/2+1×(6LWL) 3×300+2×150/2+1×(6LWL)
mm 53.7 53.7 56.6 56.6 61.2 61.2 64.4 64.4 68.7 73.8 77.5 80.5 88.5 94.7
mm 57.7 57.7 60.6 60.6 65.2 65.2 68.4 68.4 72.7 77.8 81.5 84.5 93.5 99.7
kg/km 4140 4310 4720 4880 5680 5840 6670 6870 7860 9350 10630 12040 15070 17780
18/30 kV
www.caledonian-cables.co.uk www.addison-cables.com
57
Caledonian Mining Cables Cables for Open-cast Mining
NTSCGEWOEU Medium Voltage Flexible Cable For Use In Water »» Applications These cables are designed for operation in water for connection to dredgers, floating docks, pumps, etc., in applications where high mechanical stresses are to be expected, also suitable for use in sewage, salt water and brackish water at water depths of up to 500 m.
»» Standards VDE 0250 Part 813
»» Construction Stranded Copper Conductor 3GI3 Rubber Insulation GM1b Rubber Inner Sheath Earth Conductor 5GM3 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: Rubber type 3GI3. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Split into three in the outer interstices or Individual concentric distributed over core insulating coverings (coding…../3E) or incorporated as a fourth core. Inner Sheath: Rubber compound type GM1b with characteristics of waterproof and prevention of formation of water bubbles. Outer Sheath: Waterproof rubber type 5GM3.
58
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
»» Dimensions and Weight 1.8/3kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 38.6 42.5 46.0 49.2 57.2 60.9 66.3 69.4 41.3 43.9 47.8 52.5 59.4 65.5 69.2 72.2
mm 41.6 45.5 49.0 52.2 61.2 64.9 70.3 73.4 44.3 46.9 50.8 56.5 63.4 69.5 73.2 76.2
kg/km 2480 3090 3750 4620 6200 7390 8830 10170 1180 1650 2310 3220 4335 5480 6800 8375
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×16/16 3×25/25 3×35/35 3×50/50 3×70/70 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E
mm 47.0 50.0 55.0 59.0 64.0 44.7 47.3 52.2 55.5 59.8 65.3 68.9 72.0 46.0 48.6 54.0 57.2 63.8
mm 52.0 55.0 55.0 64.0 70.0 47.7 50.3 56.2 59.5 63.8 69.3 72.9 76.0 49.0 51.6 58.0 61.2 67.8
kg/km 3240 3870 4780 5700 7000 3120 3600 4560 5470 6570 8090 9250 10600 3160 3640 4600 5510 6610
3.6/6kV
www.caledonian-cables.co.uk www.addison-cables.com
59
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 68.1 71.8 76.6
mm 72.1 75.8 80.6
kg/km 8130 9290 10840
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×16/16 3×25/25 3×35/35 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 49.0 54.0 57.0 46.4 49.0 54.0 57.2 61.5 67.0 70.7 73.7 47.8 51.9 55.5 59.0 65.5 69.8 73.5 78.3
mm 54.0 59.0 62.0 49.4 52.0 58.0 61.2 65.5 71.0 74.7 77.7 50.8 55.9 59.5 63.0 69.5 73.8 77.5 82.3
kg/km 3450 4350 5050 3320 3810 4780 5700 6830 8360 9530 10890 3360 3850 4820 5740 6870 8400 9570 10930
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E
mm 52.7 55.3 58.7 63.8 68.1 71.7 77.2 80.2 54.0 56.6 60.3 65.5
mm 56.7 59.3 62.7 67.8 72.1 75.7 81.2 84.2 58.0 60.6 64.3 69.5
kg/km 4050 4650 5390 6740 7870 9150 10770 12310 4090 4690 5430 6780
6/10 kV
8.7/15 kV
60
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 70.3 76.4 80.1 83.1
mm 74.3 80.4 84.1 87.1
kg/km 7910 9190 10810 12350
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25/25 3×35/35 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 66,0 69.0 57.0 59.6 64.8 68.1 72.4 77.9 81.5 84.3 58.3 60.9 66.4 69.8 76.4 80.7 84.2 89.0
mm 72.0 75.0 61.0 63.6 68.8 72.1 76.4 81.9 85.5 89.3 62.3 64.9 70.4 73.8 80.4 84.7 89.2 94.0
kg/km 6140 6900 4690 5260 6380 7370 8600 10290 11560 13000 4730 5300 6420 7410 8640 10330 11600 13040
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×50/50 3×70/70 3×95/95 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E
mm 81.0 86.0 92.0 64.4 67.0 70.4 73.7 79.8 83.5 88.7 91.8 65.7
mm 88.0 93.0 99.0 68.4 71.0 74.4 77.7 83.8 87.5 93.7 96.8 69.7
kg/km 9600 11100 13020 5860 8390 7220 8720 9950 11380 13120 14770 5900
12/20 kV
14/25 kV
www.caledonian-cables.co.uk www.addison-cables.com
61
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 68.3 72.0 77.2 82.0 87.9 91.6 94.6
mm 72.3 76.0 81.2 86.0 92.9 96.6 99.6
kg/km 8430 7260 8760 9990 11420 13160 14810
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×70/70 3×95/95 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+3×16/3E 3×35+3×16/3E 3×50+3×25/3E 3×70+3×35/3E 3×95+3×50/3E 3×120+3×70/3E 3×150+3×70/3E 3×185+3×95/3E
mm 93.0 97.0 69.6 72.2 77.4 80.7 84.8 90.2 93.9 96.8 70.9 73.5 79.0 82.4 88.8 93.1 96.8 101.6
mm 100.0 104.0 73.6 76.2 81.4 84.7 89.8 95.2 98.9 102.0 74.9 77.5 83.0 86.4 93.8 98.1 101.8 106.6
kg/km 12780 14350 7010 7440 8590 9670 11010 12890 14260 15780 7050 7490 8630 9710 11050 12930 14300 15820
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×70/70 3×95/95 3×95+3×50/3 3×120+3×70/3
mm 102.0 106.0 95.0 101.0
mm 110.0 114.0 102.0 109.0
kg/km 14950 16540 13670 15760
18/30kV
20/35 kV
62
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
NTSCGEWOEU Flexible Medium Voltage Trailing Cable »» Applications These cables are used as power supply or connection cables for large material handling machines, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.
»» Standards VDE 0250 Part 813
»» Construction Stranded Copper Conductor 3GI3 Rubber Insulation Reinforcing Tape 5GM5 Rubber Inner Sheath Earth Conductor 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive layer. Insulation: Rubber type 3GI3. Outer Conductor Layer: Semiconductive layer. Earth Conductor: Split into three in the outer interstices or Individual concentric distributed over core insulating coverings (coding…../3E). Reinforcing Tape: Extremely tear-resistant reinforcing tape. Inner Sheath: Rubber type 5GM5, abrasion and tear resistant, oil and ozone resistant. Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.
www.caledonian-cables.co.uk www.addison-cables.com
63
Caledonian Mining Cables Cables for Open-cast Mining
»» Dimensions and Weight 1.8/3kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 38.5 42.9 46.1 49.7 57.4 61.2 66.7 70.6 40.3 42.9 46.8 51.5 57.4 63.6 67.2 70.2
mm 41.5 45.9 49.1 53.7 61.4 65.2 70.7 74.6 44.3 46.9 50.8 55.5 62.4 68.6 72.2 75.2
kg/km 2470 3080 3750 4690 6210 7430 8900 10330 2470 3080 3750 4690 6210 7430 8900 10330
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 44.6 47.6 52.4 56.3 59.9 65.6 69.3 73.2 45.0 47.6 53.0 56.2 61.8 66.1 69.8 74.6
mm 47.6 50.6 56.4 60.3 63.9 69.6 73.3 77.2 49.0 51.6 57.0 60.2 66.8 71.1 74.8 79.6
kg/km 3080 3590 4520 5520 6580 8110 9320 10780 3200 3680 4640 5550 6650 8160 9340 10890
3.6/6kV
64
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining 6/10 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 46.4 49.1 54.1 58.0 61.7 67.4 71.0 76.7 46.8 50.9 54.5 58.0 63.5 67.8 71.5 76.3
mm 49.4 53.1 58.1 62.0 65.7 71.4 75.0 80.7 50.8 54.9 58.9 62.0 68.5 72.8 76.5 81.3
kg/km 3270 3800 4750 5750 6830 8380 9620 11430 3410 3890 4860 5780 6920 8450 9620 10980
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 52.6 55.6 58.9 64.5 68.2 72.1 77.6 81.5 53.0 55.6 59.3 64.6 68.3 74.4 78.1 81.1
mm 56.6 59.6 62.9 68.5 72.2 76.1 81.6 85.5 57.0 59.6 63.3 68.6 73.3 79.4 83.1 86.1
kg/km 4040 4630 5370 6720 7850 9130 10750 12290 4130 4740 5470 6820 7950 9240 10860 12400
8.7/15 kV
www.caledonian-cables.co.uk www.addison-cables.com
65
Caledonian Mining Cables Cables for Open-cast Mining 12/20 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 56.9 59.9 65.0 68.9 72.5 78.2 81.9 87.4 57.3 59.9 65.4 68.8 74.4 78.7 82.2 87.0
mm 60.9 63.9 69.0 72.9 76.5 82.2 85.9 92.4 61.3 63.9 69.4 72.8 79.4 83.7 87.2 92.0
kg/km 4620 5220 6300 7410 8560 10260 11570 13530 4770 5340 6460 7450 8680 10370 11650 13090
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 64.7 67.3 71.0 75.2 80.0 85.9 89.6 92.6
mm 68.7 71.3 75.0 80.2 85.0 90.9 94.6 97.6
kg/km 5940 6470 7300 8800 10050 11470 13210 14860
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×25+3×25/3 3×35+3×25/3 3×50+3×25/3 3×70+3×35/3 3×95+3×50/3 3×120+3×70/3
mm 69.5 72.5 77.6 81.5 84.9 90.6
mm 73.5 76.5 81.6 85.5 89.9 95.6
kg/km 6680 7380 8460 9690 10960 12830
14/25kV
18/30kV
66
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 3×150+3×70/3 3×185+3×95/3 3×25+2×25/2+1×10ST 3×35+2×25/2+1×10ST 3×50+2×25/2+1×10ST 3×70+2×35/2+1×10ST 3×95+2×50/2+1×10ST 3×120+2×70/2+1×10ST 3×150+2×70/2+1×10ST 3×185+2×95/2+1×10ST
mm 94.3 100.0 69.9 72.6 78.0 80.4 86.8 91.1 94.8 99.6
mm 99.3 105.0 73.9 76.6 82.0 85.4 91.8 96.1 99.8 104.6
kg/km 14250 16390 7100 7540 8680 9760 11100 12980 14350 15870
www.caledonian-cables.co.uk www.addison-cables.com
67
Caledonian Mining Cables Cables for Open-cast Mining
NTMCWOEU Flexible Medium Voltage Single Core Cable »» Applications These cables are used for connection in switch-gear and for connection of mobile transformer substations to the overhead line.
»» Standards VDE 0250 Part 813
»» Construction
Stranded Tinned Copper Conductor 3GI3 Rubber Insulation Copper Wire Screen 5GM3 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Special conductive rubber. Insulation: EPR type 3GI3. Outer Conductor Layer: Special conductive rubber. Screen: Spiral of tinned copper wires. Outer Sheath: PCP type 5GM3.
»» Dimensions and Weight 6/10kV Number of Cores×Nominal Cross Thickness of Outer Insulation Thickness Section Sheath No. ×mm² 1×16/16 1×25/16 68
mm 3.4 3.4
mm 2.2 2.2
Nominal Overall Diameter
Nominal Weight
mm 22.0 23.5
kg/km 760 910
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
Number of Cores×Nominal Cross Thickness of Outer Insulation Thickness Section Sheath No. ×mm² 1×35/16 1×50/16 1×70/16 1×95/16 1×120/16 1×150/25 1×185/25 1×240/25 1×300/25 1×400/35 1×500/35 1×630/35
mm 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
Nominal Overall Diameter
Nominal Weight
mm 24.5 27.0 28.5 30.5 33.5 35.0 37.0 41.0 43.0 46.0 49.0 53.5
kg/km 1040 1260 1530 1770 2180 2550 2900 3590 4280 5120 5950 7860
mm 2.2 2.2 2.5 2.5 2.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0
12/20kV Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No. ×mm² 1×25/16 1×35/16 1×50/16 1×70/16 1×95/16 1×120/16 1×150/25 1×185/25 1×240/25 1×300/25 1×400/35 1×500/35 1×630/35
mm 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
mm 2.5 2.5 2.5 3.0 3.0 3.0 3.5 3.5 3.5 3.5 4.0 4.0 4.0
mm 28.0 29.5 31.5 34.0 36.0 38.0 40.0 42.0 45.0 48.0 52.0 56.0 60.0
kg/km 1180 1320 1560 1920 2190 2460 2990 3350 3990 4760 6100 7010 8180
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No. ×mm² 1×25/16 1×300/25
mm 6.8 6.8
mm 3.0 4.0
mm 30.5 49.0
kg/km 1300 4900
14/25kV
www.caledonian-cables.co.uk www.addison-cables.com
69
Caledonian Mining Cables Cables for Open-cast Mining 18/30kV Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No. ×mm² 1×50/16
mm 8.0
mm 3.0
mm 35.0
kg/km 1870
Number of Cores×Nominal Cross Section
Insulation Thickness
Thickness of Outer Sheath
Nominal Overall Diameter
Nominal Weight
No. ×mm² 1×95/16 1×150/25 1×240/25
mm 9.5 9.5 9.5
mm 3.5 3.5 4.0
mm 44.0 46.3 51.7
kg/km 2900 3600 5000
20/35 kV
70
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
NTMCGCWOEU Flexible Medium Voltage Single Core Cable »» Applications These cables are used for connection in switch-gear and for connection of mobile transformer substations to the overhead line.
»» Standards VDE 0250 Part 813
»» Construction Stranded Tinned Copper Conductor 3GI3 Rubber Insulation Copper Wire Screen 5GM5 Rubber Outer Sheath
Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295. Inner Conductor Layer: Semiconductive rubber. Insulation: EPR type 3GI3. Outer Conductor Layer: Semiconductive rubber. Screen: Copper wire braid. Outer Sheath: PCP type 5GM5.
»» Dimensions and Weight 3.6/6kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×16/16KON 1×25/16KON 1×35/16KON
mm 19.4 21.4 22.6
mm 21.4 23.4 24.6
kg/km 601 825 882
www.caledonian-cables.co.uk www.addison-cables.com
71
Caledonian Mining Cables Cables for Open-cast Mining Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×50/16KON 1×70/16KON 1×95/16KON 1×120/16KON 1×150/25KON 1×185/25KON 1×240/25KON
mm 24.6 26.5 28.5 31.2 32.9 34.3 38.6
mm 27.6 29.5 31.5 34.2 35.9 37.3 41.6
kg/km 1104 1346 1614 1983 2300 2642 3371
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×16/16KON 1×25/16KON 1×35/16KON 1×50/16KON 1×70/16KON 1×95/16KON 1×120/16KON 1×150/25KON 1×185/25KON 1×240/25KON
mm 20.4 22.2 23.4 25.4 27.3 29.3 32.0 33.7 35.1 39.4
mm 22.4 24.2 25.4 28.4 30.3 32.3 35.0 36.7 38.1 42.4
kg/km 644 791 1050 1153 1399 1910 2044 2364 2709 3446
Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×16/16KON 1×25/16KON 1×35/16KON 1×50/16KON 1×70/16KON 1×95/16KON 1×120/16KON 1×150/25KON 1×185/25KON 1×240/25KON
mm 22.6 24.8 26.4 28.0 30.5 32.5 34.2 36.9 38.3 41.6
mm 24.6 27.8 29.4 31.0 33.5 35.5 37.2 39.9 41.3 44.6
kg/km 760 954 1101 1304 1623 1912 2219 2637 2995 3658
6/10 kV
8.7/15 kV
72
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining 12/20 kV Number of Cores×Nominal Cross Section
Minimium Overall Diameter
Maximum Overall Diameter
Nominal Weight
No. ×mm² 1×16/16KON 1×25/16KON 1×35/16KON 1×50/16KON 1×70/16KON 1×95/16KON 1×120/16KON 1×150/25KON 1×185/25KON 1×240/25KON
mm 26.0 27.2 28.4 31.0 32.5 34.5 37.2 38.9 40.3 43.6
mm 29.0 30.2 31.4 34.0 35.5 37.5 40.2 41.9 43.3 46.6
kg/km 971 1090 1236 1680 1776 2170 2481 3020 3182 3870
www.caledonian-cables.co.uk www.addison-cables.com
73
Caledonian Mining Cables Cables for Open-cast Mining
Flexible Fibre Optic cable »» Applications These cables are designed for the optical transmission of data and signals in tough operational conditions, such as on materials handling equipment (no reeling) or alongside conveyor belts etc., withstanding to high mechanical loads; suitable for outdoor and indoor use, also for hazardous environment.
»» Standards DIN VDE 0888 Fibre Optics Jelly Filled PETP Tubes
»» Construction
Aramid Rovings
Fiber Optics: Type: 9/125, 50/125 or 62.5/125. Plastic Tubes: PETP tubes filled with jelly. Stress Relief: Aramid rovings. Braid: Polyester fibers. Sheath: Rubber type EM5.
Polyester Fibers Braid EM5 Rubber Outer Sheath
»» Dimensions and Weight Number of Fibers & Fibre Type
Minimum Overall Diameter
Maximum Overall Diameter
Nominal Weight
1×12G50/125 1×12G62.5/125 1×12E9/125 1×18G50/125 1×18G62.5/125 1×18E9/125 1×24G50/125 1×24G62.5/125 1×24E9/125
mm 9 9 9 9 9 9 9 9 9
mm 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0
kg/km 105 105 105 105 105 105 105 105 105
74
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Cables for Open-cast Mining
Reeling Fibre Optic cable »» Applications These cables are designed for the optical transmission of data and signals in tough operational conditions, such as on materials handling equipment (no reeling) or alongside conveyor belts etc., withstanding to high mechanical loads; suitable for outdoor and indoor use, also for hazardous environment.
»» Standards
Fibre Optics Jelly Filled PETP Tubes Heat Resistant Envelope Aramid Rovings Polyester Fibers Braid 5GM5 Rubber Outer Sheath
DIN VDE 0888
»» Construction Fiber Optics: Type: 9/125, 50/125 or 62.5/125. Plastic Tubes: PETP tubes filled with jelly. Envelope: Heat resistant compound. Stress Relief: Aramid rovings. Braid: Polyester fibers. Sheath: Rubber type 5GM5.
»» Dimensions and Weight Number of Fibers & Fibre Type 2×6G50/125 2×6G62.5/125 2×6E9/125 2×9G50/125 2×9G62.5/125 2×9E9/125 2×12G50/125 2×12G62.5/125 2×12E9/125 2×18G50/125 2×18G62.5/125 2×18E9/125
Minimum Overall Diameter Maximum Overall Diameter mm 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0
mm 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0
www.caledonian-cables.co.uk www.addison-cables.com
Nominal Weight kg/km 200 200 200 200 200 200 200 200 200 200 200 200 75
Caledonian Mining Cables Technical Information
Cable Type Designation Type ..C.. (C) ...CE... ...CG... ..CGE... FM G …K... KON LWL N (N) -J -O Ö ...SH... ...SHT... ...SL... ST ...T... ...TM... ...TS... U ÜL ...W... Y 2Y... /3 /3E ...3G...
76
Type Designation Conducting metal casing over the stranded cores or between the inner and outer sheath (shield) Additional information about the shield for the conductor cross-sections, e.g. 12×1 (C) which means 1 mm² individually shielded or 6×(2×1)C which means 2×1 mm² twisted and shielded pairs Conducting metal casing over the insulation of the outer conductors Conducting non-metal casing over the stranded cores or between the inner and outer sheath (shield) Conducting non-metal casing over the insulation of the outer conductors Telecommunication lines within the cable Rubber compound Rubber cradle separator in the centre of the cable Concentric protective conductor between the inner and outer sheath or concentric control/ monitoring conductor Fibre-optic (FO) Design according to the corresponding standard Based on a standard Additional information about the type: with green/yellow marked core Additional information about the type: without green/yellow marked core Oil-resistant outer sheath (according to DIN VDE 0473, Part -2-1, Para. 10) (OE) Heavy tough rubber-sheathed flexible mining- type cable (Rough handling) 1 kV reeling cable Control cable Control cores within the cable Support element Trailing cable for medium mechanical stresses Trailing cable Flame-retardant outer sheath (according to DIN VDE 0472, Part 804) “non-inflammable“ Monitoring conductor within the cable (UEL) Weather resistant PVC compound Definition of the insulation material (2Y = PE) Protective-earth conductor uniformly distributed in the three interstices Protective-earth conductor uniformly distributed over the insulation of the outer conductor Definition of the insulating material (3G = EPR)
www.caledonian-cables.co.uk www.addison-cables.com
Caledonian Mining Cables Technical Information
Wire Diameters and Conductor Resistance Nominal cross-section
Maximum diameter of the single wires mm
Resistance of the conductor at 20℃ Ω/km
mm²
Conductor (Class 5)
Conductor (Class 6)
Bare single wires
Tinned single wires
0.5 0.75 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
0.21 0.21 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41
0.16 0.16 0.16 0.16 0.16 0.16 0.21 0.21 0.21 0.21 0.21 0.31 0.31 0.31 0.31 0.31 0.41 0.41 0.41
39 26 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641
40.1 26.7 20 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654