Rolling Stock Cables www.caledonian-cables.co.uk www.addison-cables.com
Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China, with turnover exceeding USD exceeding USD 40 million in Yr 2004. Caledonian products are sold in more than 35 countries around the globe. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets to serve the growing outsourcing needs of both multinational and regional customers.
Caledonian
Super-thin Wall Unsheathed Single Core Cables DTRF 750V....................................................................................................................... 3 Super-thin Wall Sheathed Single Core Cables DTREF 750V..................................................................................................................... 4 Super-thin Wall Multicore Cables DT-RFE 750V.................................................................................................................... 5 Super-thin Wall Screened Multicore Cables DT-RFPE 750V.................................................................................................................. 7 Low Smoke Halogen Free Flame Retardant Thin Wall Single Core Cables WDZ-DCYJB-125, WDZ-DCYJB/2-125, WDZ-DCYJB/3-125 WDZ-DCYJB-150, WDZ-DCYJB/2-150, WDZ-DCYJB/3-150 750V ................................. 9 Low Smoke Halogen Free Flame Retardant Thin Wall Multicore Cables WDZ-DCK/B-100, WDZ-DCK/B-125 250V, 750V............................................................ 11 Low Smoke Halogen Free Flame Retardant Thin Wall Screened Multicore Cables WDZ-DCKP/B-100, WDZ-DCKP/B-125 250V, 750V....................................................... 15 Low Smoke Halogen Free Flame Retardant Unsheathed Single Core Cables WDZ-DCYJ-125째C, WDZ-DCYJ/2-125째C, WDZ-DCYJ/3-125째C 750V, 1500V, 3000V........................................................................................................ 19 100째C Single Core Cables DCEYH, DCEYHR, DCEH/3-100 250V, 750V, 1.5kV, 3kV.............................................. 22 Low Smoke Halogen Free Flame Retardant Single Core Cables WDZ-DCEVM-100, WDZ-DCEVM-125 1.8/3kV.............................................................. 27 Low Smoke Halogen Free Flame Retardant Screened Single Core Cables WDZ-DCEVMP-100, WDZ-DCEVMP-125 1.8/3kV......................................................... 29 Low Smoke Halogen Free Flame Retardant Multicore Cables WDZ-DCK-100, WDZ-DCK-125 250V, 750V................................................................... 31 Low Smoke Halogen Free Flame Retardant Screened Multicore Cables WDZ-DCKP-100, WDZ-DCKP-125 250V, 750V.............................................................. 35 Railway Passenger DC Power Connector Cables WDZ-DCK-125 750V....................................................................................................... 39 Screened Railway Passenger DC Power Connector Cables WDZ-DCKP-125 750V.................................................................................................... 41
01
Caledonian Non-halogen Flame-retardant Electromagnetic Shield Power Cables WD-PWYYRP-125 1.8/3 kV............................................................................................ 43 Silicon Rubber Cables YGC-KBR 1.5 kV............................................................................................................. 44 Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKPJ-100 300/500V............................................................................................ 45 Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 20×3.5+56×1.25...................................................................... 46 Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 10×2×1.25+30×1.25................................................................ 47 Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 2×2×1.25+5×2×1.25+3×3×1.25.............................................. 48 Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 6×22+48×1.25+8×1.25P......................................................... 49
02
Caledonian Chinese Standard Rolling Stock Cables Super-thin Wall Unsheathed Single Core Cables DTRF 750V
A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires Impact Resistant
Insulation
Highly Flexible
UV Resistant
Ozone Resistant
Electron beam crosslinkable LSZH compound
Electrical & Mechanical Properties
e
Nominal Voltage Short Circuit Temperature (5s) Operating Temperature Minimum Bending Radius
e
750V Cold- resistant Resistance To Acid&Alkaline Abrasion Retardant 250°C Soldering Heat Resistant -60°C/+125°C 3 x Overall Diameter (OD≤20mm); 5 x Overall Diameter (OD≥20mm)
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T18380.1-2001 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
DTRF 750V Nominal Cross-Sectional Area mm² 0.5 0.75 1.0 1.2 1.5 2.5 4.0
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
No/mm 19/0.18 19/0.23 19/0.26 19/0.28 19/0.32 19/0.41 19/0.52
mm 0.30 0.35 0.35 0.35 0.40 0.45 0.45
mm 1.50 1.85 2.00 2.16 2.40 2.95 3.50
kg/km 7.6 12.1 14.5 16.3 21.3 33.6 50.8
Maximum Conductor Resistance 20°C Ω/km 40.1 26.7 20.0 17.6 13.7 8.21 5.00
Zero
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
3
Caledonian Chinese Standard Rolling Stock Cables Super-thin Wall Sheathed Single Core Cables DTREF 750V
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Impact Resistant
Insulation
Highly Flexible
UV Resistant
Ozone Resistant
Electron beam crosslinkable LSZH compound
Sheath
e
e
TPU plastic sheath
Electrical & Mechanical Properties
Abrasion Retardant
Cold- resistant
Resistance To Soldering Heat
Acid&Alkaline Resistant
Nominal Voltage Short Circuit Temperature (5s) Operating Temperature Minimum Bending Radius
750V 250°C -60°C/+125°C 3 x Overall Diameter (OD≤20mm); 5 x Overall Diameter (OD≥20mm)
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T18380.1-2001 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
Fire Performance
DTREF 750V Nominal Cross-Sectional Area mm² 0.5 0.75 1.0 1.2 1.5 2.5 4.0
Conductor Construction No/mm 19/0.18 19/0.23 19/0.26 19/0.28 19/0.32 19/0.41 19/0.52
Nominal Insulation Thickness mm 0.25 0.25 0.25 0.25 0.30 0.30 0.35
Nominal Sheath Maximum Thickness Overall Diameter mm 0.12 0.12 0.12 0.12 0.12 0.12 0.12
mm 1.64 1.89 2.04 2.20 2.44 2.89 3.54
Weight kg/km 7.8 11.6 14.0 15.8 20.8 31.8 49.9
Maximum Conductor Resistance 20°C Ω/km 40.1 26.7 20.0 17.6 13.7 8.21 5.00
Zero
IRM 903 Fuel Oil Resistant
4
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Super-thin Wall Multicore Cables DT-RFE 750V
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Insulation
Electron beam crosslinkable LSZH compound
Sheath
TPU plastic sheath
Electrical & Mechanical Properties Nominal Voltage Short Circuit Temperature (5s) Operating Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 250°C -60°C/+125°C 3 x Overall Diameter (OD≤20mm) 5 x Overall Diameter (OD≥20mm) GB 12666-90 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
DT-RFE 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 4×0.5 5×0.5 6×0.5 7×0.5 8×0.5 2×0.75 3×0.75 4×0.75
Conductor Construction
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
No/mm 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18 19/0.23 19/0.23 19/0.23
mm 3.84 3.97 4.60 4.82 5.06 5.40 5.96 4.14 4.71 5.16
kg/km 34.0 42.5 53.5 68.1 70.5 79.0 90.5 39.0 53.5 66.0
Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7
5
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 5×0.75 6×0.75 7×0.75 8×0.75 2×1.0 3×1.0 4×1.0 5×1.0 6×1.0 7×1.0 8×1.0 2×1.5 3×1.5 4×1.5 5×1.5 6×1.5 7×1.5 8×1.5 2×2.0 3×2.0 4×2.0 5×2.0 6×2.0 7×2.0 8×2.0 2×2.5 3×2.5 4×2.5 5×2.5 6×2.5 7×2.5 8×2.5 2×4.0 3×4.0
Conductor Construction
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
No/mm 19/0.23 19/0.23 19/0.23 19/0.23 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.52 19/0.52
mm 5.56 5.76 6.15 6.76 4.38 5.00 5.51 5.96 6.26 6.60 7.36 5.04 5.88 6.14 6.96 7.56 7.80 8.46 6.10 6.41 7.14 8.14 8.65 8.86 9.56 6.60 7.16 8.06 9.06 9.77 10.26 11.26 7.70 8.21
kg/km 77.8 92.8 104.0 117.0 45.0 63.0 77.5 93.0 111.5 126.0 143.0 52.5 82.5 105.5 120.0 144.75 164.5 185.0 63.7 94.7 122.5 152.2 181.9 210.7 240.4 77.5 118.0 142.5 169.0 213.2 240.0 280.0 111.0 160.65
Ω/km 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 10.0 10.0 10.0 10.0 10.0 10.0 10.0 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.00 5.00
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
6
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Super-thin Wall Screened Multicore Cables DT-RFPE 750V
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Insulation
Electron beam crosslinkable LSZH compound
Screen
Tinned copper wire braid
Sheath
TPU plastic sheath
Electrical & Mechanical Properties Nominal Voltage Short Circuit Temperature (5s) Operating Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 250°C -60°C/+125°C 3 x Overall Diameter (OD≤20mm) 5 x Overall Diameter (OD≥20mm) GB 12666-90 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
DT-RFPE 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 4×0.5 5×0.5 6×0.5 7×0.5 8×0.5
Conductor Construction
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
No/mm 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18 19/0.18
mm 4.10 4.23 4.84 5.06 5.20 5.34 6.20
kg/km 47.50 57.50 70.00 84.10 93.00 103.00 116.50
Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1
7
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 2×0.75 3×0.75 4×0.75 5×0.75 6×0.75 7×0.75 8×0.75 2×1.0 3×1.0 4×1.0 5×1.0 6×1.0 7×1.0 8×1.0 2×1.5 3×1.5 4×1.5 5×1.5 6×1.5 7×1.5 8×1.5 2×2.0 3×2.0 4×2.0 5×2.0 6×2.0 7×2.0 8×2.0 2×2.5 3×2.5 4×2.5 5×2.5 6×2.5 7×2.5 8×2.5 2×4.0 3×4.0
Conductor Construction
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
No/mm 19/0.23 19/0.23 19/0.23 19/0.23 19/0.23 19/0.23 19/0.23 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.26 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.32 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.37 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.41 19/0.52 19/0.52
mm 4.38 4.95 5.40 5.80 6.00 6.39 7.00 4.62 5.24 5.75 6.20 6.50 6.84 7.60 5.25 6.12 6.38 7.20 7.80 8.04 8.70 6.34 6.65 7.38 8.38 8.89 9.10 9.80 6.84 7.40 8.30 9.30 10.01 10.50 11.50 7.94 8.45
kg/km 54.00 70.55 83.50 100.25 115.25 130.00 144.50 60.50 80.50 96.57 115.26 134.00 153.55 168.35 77.50 98.50 121.60 145.00 169.95 192.00 212.50 86.50 118.30 151.50 184.90 218.60 248.40 282.10 97.50 134.00 165.00 196.80 238.20 276.90 320.00 133.50 185.65
Ω/km 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 10.0 10.0 10.0 10.0 10.0 10.0 10.0 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.00 5.00
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
8
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Thin Wall Single Core Cables WDZ-DCYJB-125, WDZ-DCYJB/2-125, WDZ-DCYJB/3-125 WDZ-DCYJB-150, WDZ-DCYJB/2-150, WDZ-DCYJB/3-150 750V
A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation Cross-link polyolefin compound
Electrical & Mechanical Properties
Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 125°C (WDZ-DCYJB-125, WDZ-DCYJB/2-125, WDZ-DCYJB/3-125); 150°C (WDZ-DCYJB-150, WDZ-DCYJB/2-150, WDZ-DCYJB/3-150) -60°C 6 x Overall Diameter
GB/T18380.1-2001; IEC 60332-3-25 D GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCYJB-125, WDZ-DCYJB/2-125, WDZ-DCYJB/3-125 WDZ-DCYJB-150, WDZ-DCYJB/2-150, WDZ-DCYJB/3-150 750V Nominal Cross-Sectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm²
No/mm
mm
mm
Ω/km
0.5
19/0.18
0.3
1.5
40.1
0.75
19/0.23
0.3
1.75
26.7
1.0
19/0.26
0.3
1.85
20.0
1.2
19/0.28
0.3
2.00
17.6
1.5
19/0.32
0.3
2.15
13.7
2.0
19/0.37
0.3
2.45
10.0
9
Caledonian Chinese Standard Rolling Stock Cables Nominal Cross-Sectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm²
No/mm
2.5
19/0.41
mm
mm
Ω/km
0.3
2.65
4
8.21
19/0.52
0.3
3.20
5.0
6
19/0.64
0.3
3.85
3.4
For WDZ-DCYJB, WDZ-DCYJB/2, WDZ-DCYJB/3 type:
e
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Zero
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
For WDZ-DCYJB/2 type:
IRM 902 Mineral Oil Resistant
For WDZ-DCYJB/3 type:
IRM 903 Fuel Oil Resistant
10
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Thin Wall Multicore Cables WDZ-DCK/B-100, WDZ-DCK/B-125 250V, 750V
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
250V, 750V 100°C (WDZ-DCK/B-100); 125°C (WDZ-DCK/B-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCK/B-100, WDZ-DCK/B-125 250V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20
mm 5.0 5.7 6.5
kg/km 38 46 65
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1
11
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5
12
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20
mm 7.0 8.7 9.5 10.0 10.5 11.5 13.0 13.4 15.0 15.2 5.5 6.2 7.2 7.7 9.7 10.7 11.2 11.7 13.4 14.6 15.1 16.9 17.2 5.9 6.6 7.6 8.2 10.5 11.5 12.5 13.1 14.4 15.8 16.4 18.7 19.0 6.5 7.2 8.4 9.1 11.7 13.3 14.0 14.6 16.2 18.1 18.8 21.0 21.4 7.4 8.2 9.7 10.5 14.0 15.5 16.3 17.1 19.4 21.3 22.1 25.0
kg/km 80 117 154 176 187 217 295 324 373 407 48 57 82 102 152 203 233 248 302 394 434 501 549 55 67 98 124 186 250 301 320 373 490 540 643 704 70 86 129 166 252 356 411 436 511 693 765 855 973 96 125 185 241 383 524 607 646 778 1034 1145 1337
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 25.4 8.6 9.5 11.3 12.7 16.5 18.7 19.7 20.7 23.2 25.5 26.5 29.8 30.3
kg/km 1474 139 186 279 382 591 833 968 1029 1230 1643 1822 2112 2334
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20
mm 5.2 5.9 6.8 7.3 9.1 10.0 10.5 11.0 12.5 13.7 14.1 15.8 16.0 5.7 6.4 7.4 8.0 10.1 11.1 11.7 12.7 14.0 15.3 15.8 18.1 18.4 6.1 6.8 7.9 8.5 10.9 12.0 13.0 13.6 15.0 16.5 17.1 19.5 19.8 6.7
kg/km 44 51 71 87 128 167 191 215 249 320 351 422 459 52 62 88 110 163 216 261 278 322 419 470 552 602 61 73 106 133 212 281 322 342 398 540 593 685 749 78
Maximum Conductor Resistance 20°C Ω/km 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
WDZ-DCK/B-100, WDZ-DCK/B-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7
13
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 7.4 8.7 9.4 12.5 13.8 14.5 15.1 16.8 18.8 19.5 21.8 22.2 7.6 8.4 10.0 10.8 14.4 16.0 16.8 18.0 20.0 22.0 23.0 25.8 26.2 8.8 9.7 11.6 13.0 16.9 19.2 20.2 21.2 23.8 26.2 27.2 30.6 31.1
kg/km 94 133 171 272 366 424 451 528 717 792 916 1007 99 129 190 247 393 537 622 680 797 1060 1185 1371 1511 142 190 285 389 599 849 986 1049 1246 1667 1849 2143 2368
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
14
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Thin Wall Screened Multicore Cables WDZ-DCKP/B-100, WDZ-DCKP/B-125 250V, 750V
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Screen Tinned copper braid Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
250V, 750V 100°C (WDZ-DCKP/B-100); 125°C (WDZ-DCKP/B-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
15
Caledonian Chinese Standard Rolling Stock Cables WDZ-DCKP/B-100, WDZ-DCKP/B-125 250V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5
16
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20
mm 5.8 6.5 7.3 7.8 9.5 10.3 10.8 11.3 12.3 13.8 14.2 15.8 16.0 6.3 7.0 8.0 8.5 10.5 11.5 12.0 12.5 14.2 15.4 15.9 17.7 18.0 6.7 7.4 8.4 9.0 11.3 12.3 13.3 13.9 15.2 16.6 17.2 19.7 20.0 7.3 8.0 9.2 9.9 12.5 14.1 14.8 15.4 17.0 19.1 19.8 22.0 22.4 8.2 9.0 10.5 11.3 14.8 16.3 17.1
kg/km 67 76 100 118 166 209 232 246 283 369 400 459 494 79 90 120 144 207 263 296 314 377 476 519 597 647 89 102 139 169 244 315 370 392 454 579 633 774 838 107 125 175 216 318 430 489 519 603 823 901 1037 1128 139 171 240 300 462 612 701
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 17.9 20.4 22.3 23.1 26.0 26.4 9.4 10.3 12.1 13.5 17.3 19.7 20.7 21.7 24.2 26.5 27.5 31.0 31.5
kg/km 744 917 1187 1306 1519 1658 189 240 344 455 686 967 1110 1178 1398 1821 2008 2366 2592
Maximum Conductor Resistance 20°C Ω/km 8.21 8.21 8.21 8.21 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
WDZ-DCKP/B-100, WDZ-DCKP/B-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20
mm 6.0 6.7 7.6 8.1 9.9 10.8 11.3 11.8 13.3 14.5 14.9 16.6 16.8 6.5 7.2 8.2 8.8 10.9 11.9 12.5 13.5 14.8 16.1 16.6 19.1 19.4 6.9 7.6 8.7 9.3 11.7 12.8 13.8 14.4 15.8
kg/km 72 80 105 124 175 219 245 260 312 389 422 485 522 83 94 126 151 216 274 310 342 394 499 543 670 722 92 106 145 176 255 328 385 408 472
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
17
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 17.3 17.9 20.5 20.8 7.5 8.2 9.5 10.2 13.3 14.6 15.3 15.9 17.6 19.8 20.5 22.8 23.2 8.4 9.2 10.8 11.6 15.2 16.8 17.6 19.0 21.0 23.0 24.0 26.8 27.2 9.6 10.5 12.4 13.8 17.7 20.2 21.2 22.2 24.8 27.2 28.2 31.8 32.3
kg/km 602 675 806 873 111 129 181 224 342 443 505 536 623 851 931 1072 1165 143 176 246 308 475 629 719 809 942 1219 1351 1559 1702 194 244 351 463 696 987 1132 1202 1418 1857 2047 2413 2643
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
18
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Unsheathed Single Core Cables WDZ-DCYJ-125, WDZ-DCYJ/2-125, WDZ-DCYJ/3-125 750V, 1500V, 3000V
A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Cross-link Polyolefin insulation
Electrical & Mechanical Properties Nominal Voltage Operating Temperature Minimum Bending Radius
750V,1500V, 3000V -55°C/+125°C 3 x Overall Diameter (OD≤20mm); 5 x Overall Diameter (OD≥20mm)
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB 12666-90 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCYJ-125, WDZ-DCYJ/2-125, WDZ-DCYJ/3-125 750V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm²
No/mm
mm
mm
kg/km
Ω/km
0.75
24/0.20
0.8
3.0
14
26.7
1.0
32/0.20
0.8
3.3
16
20.0
1.5
48/0.20
0.8
3.6
21
13.7
2.5
77/0.20
0.8
4.2
31
8.21
4
126/0.20
0.8
5.0
52
5.09
6
189/0.20
0.8
5.7
73
3.39
10
322/0.20
1.2
7.7
126
1.95
16
513/0.20
1.2
9.0
184
1.24
25
798/0.20
1.2
10.5
274
0.795
19
Caledonian Chinese Standard Rolling Stock Cables Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
mm²
No/mm
35
1121/0.20
mm
mm
kg/km
Ω/km
1.2
11.8
378
0.565
50 70
703/0.30
1.4
13.9
540
0.393
999/0.30
1.6
16.5
767
95
0.277
1332/0.30
1.6
18.6
1031
0.210
Maximum Conductor Resistance 20°C
120
1702/0.30
1.8
21.0
1267
0.164
150
2109/0.30
2.0
23.4
1557
0.132
185
1443/0.40
2.0
25.5
1881
0.108
240
1924/0.40
2.2
29.4
2518
0.0817
300
2368/0.40
2.2
32.0
3084
0.0654
WDZ-DCYJ-125, WDZ-DCYJ/2-125, WDZ-DCYJ/3-125 1500V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm²
No/mm
mm
mm
kg/km
Ω/km
0.75
24/0.20
1.2
3.9
19
26.7
1.0
32/0.20
1.2
4.1
22
20.0
1.5
48/0.20
1.2
4.4
27
13.7
2.5
77/0.20
1.2
5.0
38
8.21
4
126/0.20
1.2
5.9
55
5.09
6
189/0.20
1.2
6.6
82
3.39
10
322/0.20
1.4
8.1
131
1.95
16
513/0.20
1.4
9.4
190
1.24
25
798/0.20
1.4
10.9
282
0.795
35
1121/0.20
1.4
12.2
397
0.565
50
703/0.30
1.6
14.4
561
0.393
70
999/0.30
1.8
17.0
779
0.277
95
1332/0.30
2.0
19.4
1045
0.210
120
1702/0.30
2.2
21.4
1282
0.164
150
2109/0.30
2.4
24.2
1574
0.132
185
1443/0.40
2.4
26.3
1919
0.108
240
1924/0.40
2.6
30.2
2561
0.0817
300
2368/0.40
2.6
32.8
3177
0.0654
WDZ-DCYJ-125, WDZ-DCYJ/2-125, WDZ-DCYJ/3-125 3000V Nominal CrossSectional Area
20
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm²
No/mm
mm
mm
kg/km
Ω/km
0.75
24/0.20
1.4
4.3
26
26.7
1.0
32/0.20
1.4
4.5
28
20.0
1.5
48/0.20
1.4
4.8
34
13.7
2.5
77/0.20
1.4
5.3
46
8.21
4
126/0.20
1.4
6.3
64
5.09
6
189/0.20
1.4
7.0
87
3.39
10
322/0.20
1.6
8.5
143
1.95
16
513/0.20
1.6
9.8
203
1.24
25
798/0.20
1.6
11.3
306
0.795
35
1121/0.20
1.6
12.6
416
0.565
Caledonian Chinese Standard Rolling Stock Cables Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
mm²
No/mm
50
703/0.30
mm
mm
kg/km
Ω/km
2.0
15.2
584
0.393
70
999/0.30
2.0
17.4
804
0.277
Maximum Conductor Resistance 20°C
95
1332/0.30
2.2
19.8
1074
0.210
120
1702/0.30
2.4
21.8
1298
0.164
150
2109/0.30
2.6
24.6
1609
0.132
185
1443/0.40
2.6
26.8
1939
0.108
240
1924/0.40
2.8
30.6
2604
0.0817
300
2368/0.40
2.8
33.4
3177
0.0654
For WDZ-DCYJ, WDZ-DCYJ/2, WDZ-DCYJ/3 type:
e
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Zero
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
For WDZ-DCYJ/2 type:
IRM 902 Mineral Oil Resistant
For WDZ-DCYJ/3 type:
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
21
Caledonian Chinese Standard Rolling Stock Cables 100°C Single Core Cables DCEYH, DCEYHR, DCEH/3-100 250V, 750V, 1.5kV, 3kV
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned annealed copper wires
Separator (if available) Insulation
EPDM insulation
Sheath
CSM Sheath
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Installation Temperature Minimum Bending Radius
250V, 750V, 1.5kV, 3kV 100°C -25°C 6 x Overall Diameter (OD≤20mm); 8 x Overall Diameter (OD≥20mm)
Fire Performance Flame Retardant
GB/T18380.1-2001
DCEYH 250V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 0.5 0.75 1.0 1.5 2.5
No/mm 7/0.37 7/0.43 19/0.32 19/0.41
mm 0.4 0.4 0.4 0.4 0.4
mm 2.8 3.2 3.2 3.5 4.3
kg/km 12 15 19 25 36
Ω/km 40.1 24.8 18.7 12.5 7.59
Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 0.5 0.75 1.0 1.5 2.5
No/mm 16/0.20 24/0.20 32/0.20 30/0.25(48/0.20) 49/0.25(77/0.20)
mm 0.4 0.4 0.4 0.4 0.4
mm 2.8 3.2 3.2 3.5 4.3
kg/km 12 15 19 25 36
Ω/km 40.1 26.7 20.0 13.7 8.21
DCEYHR 250V
22
Caledonian Chinese Standard Rolling Stock Cables DCEYH 750V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 7/0.37 7/0.43 19/0.32 19/0.41 19/0.52 19/0.64 49/0.52 84/0.49 133/0.49 189/0.49 259/0.49 259/0.58 259/0.68 336/0.67 427/0.67 570/0.67 732/0.64 912/0.64
mm 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 1.0 1.0 1.2 1.2 1.4 1.4 1.8 1.8 2.2 2.2
mm 4.0 4.1 4.4 5.1 5.7 6.4 8.6 10.5 13.0 14.5 17.0 19.0 21.5 23.5 27.8 29.5 34.0 37.0
kg/km 21 24 31 45 63 86 152 243 350 471 624 830 1137 1400 1817 2186 2683 3462
Ω/km 24.8 18.7 12.5 7.59 4.54 3.00 1.78 1.20 0.760 0.535 0.390 0.271 0.197 0.156 0.123 0.101 0.0787 0.0632
Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 24/0.20 32/0.20 30/0.25(48/0.20) 49/0.25(77/0.20) 56/0.30(128/0.20) 84/0.30 84/0.40 126/0.40 196/0.40 276/0.40 396/0.40 380/0.49 513/0.49 630/0.49 777/0.49 976/0.49 1281/0.49 1586/0.49
mm 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 1.0 1.0 1.2 1.2 1.4 1.4 1.8 1.8 2.2 2.2
mm 4.0 4.1 4.4 5.1 5.7 6.4 8.6 10.5 13.0 14.5 17.0 19.0 21.5 23.5 27.8 29.5 34.0 37.0
kg/km 21 24 31 45 63 86 152 243 350 471 624 830 1137 1400 1817 2186 2683 3462
Ω/km 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
DCEYHR 750V
DCEH/3-100 750V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 0.5 0.75 1.0 1.5 2.5 4 6 10 16 25 35
No/mm 16/0.20(28/0.15) 24/0.20(42/0.15) 32/0.20(56/0.15) 30/0.25(85/0.15) 50/0.25(140/0.15) 56/0.30(228/0.15) 84/0.30(189/0.20) 80/0.40(324/0.20) 126/0.40(513/0.20) 196/0.40(783/0.20) 276/0.40(1107/0.20)
mm 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 1.0 1.0
mm 4.4 4.7 4.9 5.4 5.2 6.8 7.8 9.0 10.5 13.0 14.5
kg/km 17 21 24 31 45 63 86 152 243 350 471
Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565
23
Caledonian Chinese Standard Rolling Stock Cables Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 50 70 95 120 150 185 240 300
No/mm 396/0.40(702/0.30) 360/0.50(999/0.30) 475/0.50(1332/0.30) 608/0.50(1702/0.30) 756/0.50(2109/0.30) 925/0.50(1443/0.40) 1221/0.50(1891/0.40) 1525/0.50(2379/0.40)
mm 1.2 1.2 1.4 1.4 1.8 1.8 2.2 2.2
mm 17.0 19.5 21.5 23.5 28.0 29.5 34.0 37.0
kg/km 624 830 1137 1400 1817 2186 2683 3462
Ω/km 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
DCEYH 1500V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 7/0.43 19/0.32 19/0.41 19/0.52 19/0.64 49/0.52 84/0.49 133/0.49 189/0.49 259/0.49 259/0.58 259/0.68 336/0.67 427/0.67 570/0.67 732/0.64 912/0.64
mm 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 2.0 2.0 2.4 2.4
mm 4.9 5.3 6.2 6.8 7.5 9.5 11.0 13.5 15.0 17.9 19.0 22.5 24.0 27.0 29.0 35.0 38.0
kg/km 32 40 58 77 101 169 250 361 483 651 864 1177 1443 1840 2211 2926 3529
Ω/km 18.7 12.5 7.59 4.54 3.0 1.78 1.20 0.76 0.535 0.390 0.271 0.197 0.156 0.123 0.101 0.0787 0.0632
Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 32/0.20 30/0.25(48/0.20) 49/0.25(77/0.20) 56/0.30(128/0.20) 84/0.30 84/0.40 126/0.40 196/0.40 276/0.40 396/0.40 380/0.49 513/0.49 630/0.49 777/0.49 976/0.49 1281/0.49 1586/0.49
mm 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 2.0 2.0 2.4 2.4
mm 4.9 5.3 6.2 6.8 7.5 9.5 11.0 13.5 15.0 17.9 19.0 22.5 24.0 27.0 29.0 35.0 38.0
kg/km 32 40 58 77 101 169 250 361 483 651 864 1177 1443 1840 2211 2926 3529
Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
DCEYHR 1500V
24
Caledonian Chinese Standard Rolling Stock Cables DCEH/3-100 1500V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 32/0.20(56/0.15) 30/0.25(85/0.15) 50/0.25(140/0.15) 56/0.30(228/0.15) 84/0.30(189/0.20) 84/0.40(324/0.20) 126/0.40(513/0.20) 196/0.40(783/0.20) 276/0.40(1107/0.20) 396/0.40(702/0.30) 360/0.50(999/0.30) 475/0.50(1332/0.30) 608/0.50(1702/0.30) 756/0.50(2109/0.30) 925/0.50(1443/0.40) 1221/0.50(1891/0.40) 1525/0.50(2379/0.40)
mm 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 2.0 2.0 2.4 2.4
mm 6.0 6.6 7.6 8.2 8.8 9.8 11.0 13.5 15.0 18.0 19.5 22.5 24.5 28.0 30.0 35.0 38.0
kg/km 32 40 58 77 101 169 250 361 483 651 864 1177 1443 1840 2211 2926 3529
Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.101 0.0817 0.0654
DCEYH 3000V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 19/0.41 19/0.52 19/0.64 49/0.52 84/0.49 133/0.49 189/0.49 259/0.49 259/0.58 259/0.68 336/0.67 427/0.67 570/0.67 732/0.64 912/0.64
mm 1.4 1.4 1.4 1.6 1.6 1.8 1.8 2.0 2.0 2.2 2.2 2.6 2.6 3.0 3.0
mm 8.0 8.6 9.2 11.2 15.5 15.5 17.0 20.0 22.0 24.5 26.5 30.0 32.0 37.0 40.0
kg/km 83 104 131 205 281 410 539 733 954 1200 1556 1966 2348 3089 3702
Ω/km 7.59 4.54 3.0 1.78 1.20 0.76 0.535 0.390 0.271 0.197 0.156 0.123 0.101 0.0787 0.0632
Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 49/0.25(77/0.20) 56/0.30(128/0.20) 84/0.30 84/0.40 126/0.40 196/0.40 276/0.40 396/0.40 380/0.49 513/0.49 630/0.49 777/0.49 976/0.49 1281/0.49 1586/0.49
mm 1.4 1.4 1.4 1.6 1.6 1.8 1.8 2.0 2.0 2.2 2.2 2.6 2.6 3.0 3.0
mm 8.0 8.6 9.2 11.2 15.5 15.5 17.0 20.0 22.0 24.5 26.5 30.0 32.0 37.0 40.0
kg/km 83 104 131 205 281 410 539 733 954 1200 1556 1966 2348 3089 3702
Ω/km 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
DCEYHR 3000V
25
Caledonian Chinese Standard Rolling Stock Cables DCEH/3-100 3000V Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Maximum Overall Diameter
Weight
Maximum Conductor Resistance 20°C
mm² 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
No/mm 50/0.25(140/0.15) 56/0.30(228/0.15) 84/0.30(189/0.20) 80/0.40(324/0.20) 126/0.40(513/0.20) 196/0.40(783/0.20) 276/0.40(1107/0.20) 396/0.40(702/0.30) 360/0.50(999/0.30) 475/0.50(1332/0.30) 608/0.50(1702/0.30) 756/0.50(2109/0.30) 925/0.50(1443/0.40) 1221/0.50(1891/0.40) 1525/0.50(2379/0.40)
mm 1.4 1.4 1.4 1.6 1.6 1.8 1.8 2.0 2.0 2.2 2.2 2.6 2.6 3.0 3.0
mm 8.6 9.2 10.0 12.5 15.5 15.5 17.0 20.0 22.0 24.5 26.5 30.0 32.0 37.0 40.0
kg/km 83 104 131 205 281 410 539 733 954 1200 1556 1966 2348 3089 3702
Ω/km 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
e
IRM 903 Fuel Oil Resistant
26
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Cold- resistant
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Single Core Cables WDZ-DCEVM-100, WDZ-DCEVM-125 1.8/3kV
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
1.8/3kV 100°C (WDZ-DCEVM-100); 125°C (WDZ-DCEVM-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T18380.1-2001; GB/T18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCEVM-100, WDZ-DCEVM-125 1.8/3kV Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Nominal Sheath Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm² 2.5 4 6 10 16 25 35 50
No/mm 77/0.20 77/0.26 84/0.30 84/0.40 126/0.40 196/0.40 276/0.40 396/0.40
mm 0.9 0.9 0.9 1.0 1.0 1.2 1.2 1.2
mm 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.1
mm 6.5 7.2 7.9 9.2 11.0 13.2 14.5 16.2
Ω/km 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393
27
Caledonian Chinese Standard Rolling Stock Cables Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Nominal Sheath Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm² 70 95 120 150 185 240 300
No/mm 380/0.49 513/0.49 630/0.49 777/0.49 976/0.49 1281/0.49 1586/0.49
mm 1.4 1.6 1.6 1.8 1.8 1.8 1.8
mm 1.4 1.6 1.6 1.7 1.7 1.7 1.7
mm 19.0 22.0 24.0 26.0 28.5 30.9 33.5
Ω/km 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654
e
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
28
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Screened Single Core Cables WDZ-DCEVMP-100, WDZ-DCEVMP-125 1.8/3kV
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Screen
Tinned copper braid
Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
1.8/3kV 100°C (WDZ-DCEVMP-100); 125°C (WDZ-DCEVMP-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T18380.1-2001; GB/T18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCEVMP-100, WDZ-DCEVMP-125 1.8/3kV Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Nominal Sheath Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm² 16 25 35 50 70
No/mm 126/0.40 196/0.40 276/0.40 396/0.40 380/0.49
mm 1.0 1.2 1.2 1.2 1.4
mm 1.0 1.1 1.1 1.1 1.4
mm 13.0 15.0 17.0 18.5 21.0
Ω/km 1.24 0.795 0.565 0.393 0.277
29
Caledonian Chinese Standard Rolling Stock Cables Nominal CrossSectional Area
Conductor Construction
Nominal Insulation Thickness
Nominal Sheath Thickness
Maximum Overall Diameter
Maximum Conductor Resistance 20°C
mm² 95 120 150
No/mm 513/0.49 630/0.49 777/0.49
mm 1.6 1.6 1.8
mm 1.6 1.6 1.7
mm 23.0 24.5 26.5
Ω/km 0.210 0.164 0.132
e
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
30
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Multicore Cables WDZ-DCK-100, WDZ-DCK-125 250V, 750V
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
250V, 750V 100°C (WDZ-DCK-100); 125°C (WDZ-DCK-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCK-100, WDZ-DCK-125 250V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20
mm 6.6 7.3
kg/km 62 70
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1
31
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5
32
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20
mm 8.4 9.0 11.2 12.2 13.2 13.8 15.1 16.5 17.0 19.4 19.7 7.1 7.9 9.0 9.7 12.2 13.8 14.4 15.0 16.6 18.1 19.1 21.3 21.6 7.5 8.2 9.5 10.2 13.3 14.6 15.3 16.0 17.6 19.7 20.4 22.7 23.1 8.1 8.9 10.3 11.1 14.5 16.0 16.8 17.5 19.8 21.6 22.4 25.4 25.8 9.0 9.9 11.6 12.5 16.5 18.2 19.5 20.4 22.6 25.2 26.1
kg/km 96 116 167 215 256 272 313 398 436 487 564 71 83 113 141 206 282 320 342 394 507 574 661 720 80 94 133 164 256 333 381 405 470 629 690 795 868 97 115 167 210 328 436 499 531 638 831 913 1081 1182 126 159 228 291 457 616 709 775 905 1217 1342
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 29.2 29.7 10.6 11.6 14.1 15.3 20.2 22.3 23.5 25.1 27.8 30.5 31.7 36.6 37.2
kg/km 1551 1702 179 233 356 459 721 979 1132 1231 1441 1910 2111 2536 2786
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20
mm 7.8 8.6 10.0 10.8 14.1 15.4 16.2 17.0 19.1 20.9 21.6 24.6 24.9 8.3 9.1 10.7 11.5 15.1 16.6 17.4 18.6 20.6 22.5 23.3 26.5 26.9 8.7 9.5 11.1 12.0 15.8 17.4 18.7 19.6 21.6 24.1 25.0 27.9 28.4
kg/km 78 89 124 151 239 302 340 364 437 557 607 723 783 89 103 145 178 280 362 410 457 526 674 740 878 955 98 115 163 203 319 415 494 527 609 812 889 1024 1116
Maximum Conductor Resistance 20°C Ω/km 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
WDZ-DCK-100, WDZ-DCK-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
33
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0 2×10
Conductor Construction
Overall Diameter
Weight
No/mm 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 332/0.20
mm 9.3 10.2 11.9 13.3 17.0 19.2 20.2 21.1 23.4 26.0 27.0 30.2 30.7 10.2 11.2 13.6 14.7 19.4 21.4 22.5 24.0 26.6 29.2 30.3 35.0 35.6 11.4 12.5 15.2 16.5 21.9 24.6 25.9 27.2 30.2 33.2 35.5 39.8 40.5 18.4
kg/km 116 143 200 265 396 544 623 644 769 1030 1131 1305 1427 147 186 278 352 552 736 847 928 1080 1417 1561 1891 2069 193 251 384 496 784 1083 1250 1329 1557 2063 2370 2741 3011 430
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 1.95
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
34
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Screened Multicore Cables WDZ-DCKP-100, WDZ-DCKP-125 250V, 750V
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Screen Tinned copper braid Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
250V, 750V 100°C (WDZ-DCKP-100); 125°C (WDZ-DCKP-125) -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
Fire Performance
WDZ-DCKP-100, WDZ-DCKP-125 250V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20
mm 7.4 8.1
kg/km 97 107
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1
35
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5
36
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20
mm 9.2 9.8 12.0 13.0 14.0 14.6 15.9 17.3 17.8 20.4 20.7 7.9 8.7 9.8 10.5 13.0 14.6 15.2 15.8 17.4 18.9 20.1 22.3 22.6 8.3 9.0 10.3 11.0 14.1 15.4 16.1 16.8 18.4 20.7 21.4 23.7 24.1 8.9 9.7 11.1 11.9 15.3 16.8 17.6 18.3 20.8 22.6 23.4 26.4 26.8 9.8 10.7 12.4 13.3 17.3 19.0 20.5 21.4 23.6 26.2 27.1
kg/km 139 163 228 282 327 347 396 490 530 622 701 109 122 159 191 272 356 398 424 484 607 706 809 871 120 136 182 218 327 412 464 493 567 765 831 953 1029 140 161 221 269 407 523 591 628 773 982 1068 1259 1336 176 212 291 360 549 718 865 919 1065 1395 1527
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 30.4 30.9 11.4 12.4 14.9 16.1 21.2 23.3 24.5 26.1 28.8 31.7 32.9 37.8 38.4
kg/km 1800 1956 239 296 433 543 862 1137 1299 1408 1638 2173 2383 2755 3009
Conductor Construction
Overall Diameter
Weight
No/mm 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20
mm 8.6 9.4 10.8 11.6 14.9 16.2 17.0 17.8 20.1 21.9 22.6 25.6 25.9 9.1 9.9 11.5 12.3 15.9 17.4 18.2 19.6 21.6 23.5 24.3 27.5 27.9 9.5 10.3 11.9 12.8 16.6 18.2 19.7 20.6 22.6 25.1 26.0 28.9 29.4
kg/km 100 113 153 182 277 343 384 410 509 636 689 808 870 112 128 175 211 319 406 457 525 603 759 828 970 1048 123 141 195 238 361 462 563 600 690 894 974 1121 1215
Maximum Conductor Resistance 20°C Ω/km 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
WDZ-DCKP-100, WDZ-DCKP-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×0.5 3×0.5 5×0.5 7×0.5 11×0.5 16×0.5 19×0.5 20×0.5 24×0.5 33×0.5 37×0.5 43×0.5 48×0.5 2×0.75 3×0.75 5×0.75 7×0.75 11×0.75 16×0.75 19×0.75 20×0.75 24×0.75 33×0.75 37×0.75 43×0.75 48×0.75 2×1.0 3×1.0 5×1.0 7×1.0 11×1.0 16×1.0 19×1.0 20×1.0 24×1.0 33×1.0 37×1.0 43×1.0 48×1.0
Maximum Conductor Resistance 20°C Ω/km 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
37
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 2×1.5 3×1.5 5×1.5 7×1.5 11×1.5 16×1.5 19×1.5 20×1.5 24×1.5 33×1.5 37×1.5 43×1.5 48×1.5 2×2.5 3×2.5 5×2.5 7×2.5 11×2.5 16×2.5 19×2.5 20×2.5 24×2.5 33×2.5 37×2.5 43×2.5 48×2.5 2×4.0 3×4.0 5×4.0 7×4.0 11×4.0 16×4.0 19×4.0 20×4.0 24×4.0 33×4.0 37×4.0 43×4.0 48×4.0
Conductor Construction
Overall Diameter
Weight
No/mm 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 48/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.20 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26 77/0.26
mm 10.0 11.0 12.7 14.1 17.8 20.2 21.2 22.1 24.4 27.0 28.0 31.4 31.9 11.0 12.0 14.4 15.5 20.4 22.4 23.5 25.0 27.6 30.4 31.5 36.2 36.8 12.2 13.3 16.0 17.3 22.9 25.6 26.9 28.2 31.4 34.4 36.7 41.0 41.7
kg/km 143 172 235 299 442 615 698 744 858 1120 1224 1455 1580 180 218 314 391 623 816 933 1011 1173 1562 1712 2033 2213 228 288 424 540 867 1168 1340 1424 1707 2230 2514 2904 3177
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 8.21 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09 5.09
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
38
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Railway Passenger DC Power Connector Cables WDZ-DCK-125 750V
A. Conductor B. Insulation C. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 125°C -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCK-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×6 3×6 4×6 3×10
Conductor Construction
Overall Diameter
Weight
No/mm 189/0.20 189/0.20 189/0.20 322/0.20
mm 14.1 15.0 16.4 19.3
kg/km 289 375 470 603
Maximum Conductor Resistance 20°C Ω/km 3.39 3.39 3.39 1.95
39
Caledonian Chinese Standard Rolling Stock Cables Number of conductor×Nominal Cross-Sectional Area mm² 4×10 2×16 3×16 4×16 2×25 3×25 4×25 2×35 3×35 4×35 2×50 3×50 4×50
Conductor Construction
Overall Diameter
Weight
No/mm 322/0.20 513/0.20 513/0.20 513/0.20 798/0.20 798/0.20 798/0.20 1121/0.20 1121/0.20 1121/0.20 703/0.30 703/0.30 703/0.30
mm 21.2 20.6 22.1 24.3 24.0 25.6 28.6 26.6 28.5 31.7 31.0 33.1 36.7
kg/km 761 630 850 1079 887 1198 1554 1141 1580 2047 1573 2160 2819
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 1.95 1.24 1.24 1.24 0.79 0.79 0.79 0.56 0.56 0.56 0.393 0.393 0.393
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
40
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Screened Railway Passenger DC Power Connector Cables WDZ-DCKP-125 750V
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Separator (if available) Insulation
Low smoke halogen free flame retardant compound
Filler Separator Screen Tinned copper braid Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 125°C -40°C 2 x Overall Diameter (OD≤10mm); 4 x Overall Diameter (10mm≤OD≤20mm); 6 x Overall Diameter (OD≥20mm)
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
41
Caledonian Chinese Standard Rolling Stock Cables WDZ-DCK-125 750V Number of conductor×Nominal Cross-Sectional Area mm² 2×6 3×6 4×6 3×10 4×10 2×16 3×16 4×16 2×25 3×25 4×25 2×35 3×35 4×35 2×50 3×50 4×50
Conductor Construction
Overall Diameter
Weight
No/mm 189/0.20 189/0.20 189/0.20 322/0.20 322/0.20 513/0.20 513/0.20 513/0.20 798/0.20 798/0.20 798/0.20 1121/0.20 1121/0.20 1121/0.20 703/0.30 703/0.30 703/0.30
mm 14.9 15.8 17.2 20.3 22.4 21.6 23.1 25.5 25.2 26.6 29.8 27.8 29.5 32.9 32.2 34.5 38.1
kg/km 361 452 554 729 912 764 994 1252 1056 1367 1780 1329 1768 2297 1819 2439 3130
e
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 3.39 3.39 3.39 1.95 1.95 1.24 1.24 1.24 0.79 0.79 0.79 0.56 0.56 0.56 0.393 0.393 0.393
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
42
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Non-halogen Flame-retardant Electromagnetic Shield Power Cables WD-PWYYRP-125 1.8/3 kV
A. Conductor B. Insulation C. Screen D. Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Soft tinned annealed brass wires
Insulation
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
125°C non-halogen flame-retardant compound
Screen
Tinned copper wire braid
e
e
Sheath
125°C non-halogen flame-retardant compound.
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Short Circuit Temperature (5s) Long-term Working Ambient Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
Abrasion Retardant
Cold- resistant
Resistance To Soldering Heat
Acid&Alkaline Resistant
1.8/3 kV 125°C 250°C -40°C/+70°C 5 x Overall Diameter GB 12666.2-1990 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WD-PWYYRP-125 1.8/3 kV Nominal Cross-Sectional Area mm² 35 70
Stranding
Insulation Thickness
Sheath Thickness
Maximum Overall Diameter
Weight
No/mm 1107/0.2 2220/0.2
mm 1.8 1.9
mm 1.2 1.5
mm 16.5 21.0
kg/km 666 1172
Maximum Conductor Resistance 20°C Ω/km 0.393 0.210
Zero
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
43
Caledonian Chinese Standard Rolling Stock Cables Silicon Rubber Cables YGC-KBR 1.5 kV
A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned annealed copper wires
Insulation
High tear strength silicon rubber
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Short Circuit Temperature (5s) Ambient Temperature Minimum Bending Radius
1500V 150°C 300°C -50°C/+150°C 3 x Overall Diameter
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T18380.1-2001 DZ-1 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
YGC-KBR 1.5 kV Nominal Cross-Sectional Area mm² 50 95
Stranding
Insulation Thickness
Maximum Overall Diameter
Weight
No/mm 999/0.25 1936/0.25
mm 3.5 3.5
mm 18.5 22.5
kg/km 911 1485
e
Impact Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant
Maximum Conductor Resistance 20°C Ω/km 0.393 0.210
e
Resistance To Soldering Heat
Acid&Alkaline Resistant
Zero
IRM 903 Fuel Oil Resistant
44
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKPJ-100 300/500V Tinned Copper Conductor Screened Wire Filler LSZH Flame Retardant Insulation LSZH Flame Retardant Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Unscreened Conductors
Tinned copper wires with low smoke halogen free flame retardant insulation Screened Wires
Corona Resistant
Highly Flexible
2×1mm² tinned copper wires with low smoke halogen free flame retardant insulation and screen.
UV Resistant
e
Ozone Resistant
e
Filler Sheath
Abrasion Retardant
Cold- resistant
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Resistance To Soldering Heat
Acid&Alkaline Resistant
300/500V 100°C -25°C 6 x Overall Diameter
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCKPJ-100 Number of conductor×Nominal Cross-Sectional Area mm² 24×1.5+2×1
Conductor Construction No/mm 24×48/0.20+2×32/0.20
Nominal Insulation Thickness mm 0.8/0.6
Nominal Sheath Nominal Overall Thickness Diameter mm 2.0
mm 25.3
Maximum Conductor Resistance 20°C Ω/km 13.7/20.0
Zero
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
45
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 20×3.5+56×1.25 Tinned Copper Conductor LSZH Flame Retardant Insulation Filler Fiber Braid Single Wrapped LSZH Flame Retardant Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Insulation
Low smoke halogen free flame retardant compound
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Single Wrapped Filler
e
e
Fiber Braid Abrasion Retardant
Sheath
Cold- resistant
Resistance To Soldering Heat
Acid&Alkaline Resistant
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
750V 125°C -25°C 6 x Overall Diameter
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCKT-P-125 Number of conductor×Nominal Cross-Sectional Area mm² 20×3.5+56×1.25
Conductor Construction No/mm 20×66/0.26+56×50/0.18
Nominal Insulation Thickness mm 1.0/0.8
Nominal Sheath Thickness mm 3.3
Nominal Overall Diameter mm 49
Maximum Conductor Resistance 20°C Ω/km 5.38/15.5
Zero
IRM 903 Fuel Oil Resistant
46
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 10×2×1.25+30×1.25 LSZH Flame Retardant Sheath Tinned Copper Conductor LSZH Flame Retardant Insulation Screen Filler LSZH Flame Retardant Sheath Fiber Braid
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Single Conductors
Tinned copper wires with low smoke halogen free flame retardant insulation and single wrapping.
Twisted Pairs
Consisted of tinned copper wires, low smoke halogen free flame retardant insulation, wrapping, screen and low smoke halogen free flame retardant sheath
Filler
Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Fiber Braid Outer Sheath
e
e
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties
Abrasion Retardant
Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Cold- resistant
750V 125°C -25°C 6 x Overall Diameter
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
Resistance To Soldering Heat
Acid&Alkaline Resistant
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCKT-P-125 Number of conductor×Nominal Cross-Sectional Area mm² 10×2×1.25+30×1.25
Conductor Construction
Nominal Insulation Thickness
Nominal Inner Sheath Thickness
Nominal Outer Sheath Thickness
Nominal Overall Diameter
No/mm 10×2×50/0.18+30×50/0.18
mm 0.7
mm 0.8
mm 3.3
mm 49
Maximum Conductor Resistance 20°C Ω/km 15.5
Zero
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
47
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 2×2×1.25+5×2×1.25+3×3×1.25 Wapped Tinned Copper Conductor LSZH Flame Retardant Insulation Screen LSZH Flame Retardant Sheath LSZH Flame Retardant Element Sheath Filler LSZH Flame Retardant Outer Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction 5×2×50/0.18mm² &2×2×1.25mm² Element
Tinned copper wires with low smoke halogen free flame retardant insulation. Two insulated wires are twisted together to form a pair. Every pair is screened and sheathed. Pairs are stranded with fillers and covered with an element sheath.
3×3×1.25mm² Element
Tinned copper wires with low smoke halogen free flame retardant insulation. There insulated wires are twisted together to form a triple. Every triple is screened and sheathed. Triples are stranded with fillers and covered with an element sheath.
Filler Wrapped Outer Sheath
Low smoke halogen free flame retardant compound.
Electrical & Mechanical Properties
Corona Resistant
UV Resistant
Highly Flexible
e
Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
750V 125°C Abrasion Retardant -25°C 6 x Overall Diameter
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
Ozone Resistant
e
Cold- resistant
Resistance To Soldering Heat
Acid&Alkaline Resistant
GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCKT-P-125 Number of conductor×Nominal Cross-Sectional Area mm² 2×2×1.25+5×2×1.25 +3×3×1.25
Conductor Construction
Nominal Insulation Nominal Inner Thickness Sheath Thickness
No/mm 2×2×50/0.18+5×2×50/0.1 8+3×3×50/0.18
Nominal Outer Nominal Overall Sheath Thickness Diameter
mm
mm
mm
mm
0.8
0.8/1.0
3.5
56
Zero
IRM 903 Fuel Oil Resistant
48
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
Caledonian Chinese Standard Rolling Stock Cables Low Smoke Halogen Free Flame Retardant Rolling Stock Multicore Jumper Cables WDZ-DCKT-P-125 750V 6×22+48×1.25+8×1.25P Tinned Copper Conductor LSZH Flame Retardant Insulation Filler Fiber Braid Single Wrapped LSZH Flame Retardant Sheath
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor. -Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction Conductor
Tinned copper wires
Insulation
Corona Resistant
Low smoke halogen free flame retardant compound
UV Resistant
Highly Flexible
Ozone Resistant
Single Wrapped e
Screen Filler
Abrasion Retardant
e
Cold- resistant
Resistance To Soldering Heat
Wrapped
Acid&Alkaline Resistant
Fiber Braid Outer Sheath
Low smoke halogen free flame retardant compound
Electrical & Mechanical Properties Nominal Voltage Long-term Working Temperature Lowest Operation Temperature Minimum Bending Radius
Fire Performance
Flame Retardant Low Corrosivity (Acidity & Conductivity) Halogen Free Low Smoke
750V 125°C -25°C 6 x Overall Diameter GB/T 18380.1-2001; GB/T 18380.3-2001 C GB/T17650.1-1998; GB/T17650.2-1998 GB/T17650.1-1998; GB/T17650.2-1998 GB/T17651.1-1998; GB/T17651.2-1998
WDZ-DCKT-P-125 Number of conductor×Nominal Cross-Sectional Area mm² 6×22+48×1.25+8×1.25P
Conductor Construction No/mm 6×418/0.26+48×48/0.18+3/0.25+8× 48/0.18+3/0.25
Nominal Insulation Thickness mm
Nominal Outer Sheath Thickness mm
Nominal Overall Diameter mm
1.2/0.8
4.0
53
Zero
IRM 903 Fuel Oil Resistant
IRM 902 Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1
Low Toxicity
NF X70-100/NF F63 808 TM1-04/BS 6853
Low Corrosivity
Low Smoke Emission
IEC60754-2/EN50267-2-2/3 IEC 61034-2 / EN 50268-2 NF C32-074/VDE 0472-813 NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815
49